FEATURES. **Caution: Temperature and pressure affect the strength and chemical resistance of plastic and rubber.

Size: px
Start display at page:

Download "FEATURES. **Caution: Temperature and pressure affect the strength and chemical resistance of plastic and rubber."

Transcription

1 ACCU-PULSE I Pulsation Dampeners Chargeable / Plastic / Dome Top lightweight, compact design 150 psi rating extensive range of materials Technical Data FEATURES remove pulsating flows from positive displacement pumps increase system efficiency and pump life decrease maintenance and costs protect pipes, meters, instruments, valves, gaskets and seals from pulsation and vibration ensure meter accuracy, longevity and repeatability reduce pressure fluctuations and diaphragm wear prevent foaming and splashing easy in-line maintenance 2 year warranty Unit Capacity: 10 CU In Weight: 1 pound Air Control: Gas Fill Valve Inlet Port: 1/2" NPTF, optional 3/8" NPTF Pressure Limit: 150 psi at 70 F ** Shell Materials: Polypropylene, PVC, PVDF Elastomers: Neoprene, Buna-N, EPDM, Viton, Hypalon, Teflon **Caution: Temperature and pressure affect the strength and chemical resistance of plastic and rubber. PRIMARY FLUID SYSTEMS INC. Call Toll Free Tel (905) Fax (905) primary@primary fluid.com

2 ACCU-PULSE I Operation: ACCU-Pulse pulsation dampeners operate on the principal that volume is inversely proportional to pressure. Compressed air or gas is introduced into the top section of ACCU-Pulse to a specified pressure that must be lower than the pump's discharge pressure. When a pump or valve introduces a pulse, fluid enters the dampener and compresses the trapped gas. The fluid remains in the dampener until the system pressure returns to normal, when the valve is reopened or the pump begins its next cycle. The fluid is then pushed back into the system piping as the trapped gas expands. ACCU-Pulse does NOT restrict fluid flow, or increase system pressure. ACCU-Pulse fills the fluid voids and pressure fluctuations created by reciprocating pumps. Typical Installations: Pulsation Dampeners Dimensions: Parts Description: Item Part # Qty Description Material ^ 1 Wetted Housing PVC P ^ Wetted Housing GF Polypropylene K ^ Wetted Housing PVDF 10X-050 Wetted Housing CPVC Bladder Neoprene Bladder EPDM Bladder Buna-N Bladder Hypalon Bladder Viton Bladder Aflas P Bladder (PVC & PP) Teflon K Bladder (PVDF) Teflon 3A NonWetted Housing PVC P NonWetted Housing GF Polypropylene K NonWetted Housing PVDF 10X-024 NonWetted Housing CPVC Fastener Assembly S/S ( Set of 6 ) Chargeable Air Assembly Plastic, Brass, S/S ^ add suffix -0 for units with 3/8" connections ^ add suffix -1 for units with 1/2" connections Recommended Spare Parts WA SA & NT VIC & TAS NSW & ACT Call Toll Free QLD (08) (08) (03) (02) (07) Tel: 3802 (905) hydramet@hydramet.com.au hydrasa@hydramet.com.au hydravic@hydramet.com.au hydransw@hydramet.com.au hydraqld@hydramet.com.au Fax: (905) Distribution Territories Available E:Mail: primary@primaryfluid.com Registered Trade Mark of Primary Fluid Systems e 2

3 ACCU-PULSE II Pulsation Dampeners Chargeable / Plastic / Dome Top lightweight, compact design 150 psi rating extensive range of materials Technical Data PRIMARY FLUID SYSTEMS INC. FEATURES Call Toll Free Tel (905) Fax (905) remove pulsating flows from positive displacement pumps increase system efficiency and pump life decrease maintenance and costs protect pipes, meters, instruments, valves, gaskets and seals from pulsation and vibration ensure meter accuracy, longevity and repeatability reduce pressure fluctuations and diaphragm wear prevent foaming and splashing easy in-line maintenance 2 year warranty Unit Capacity: 85 CU In Weight: 6-7 pounds Air Control: Gas Fill Valve Inlet Port: 3/4" NPTF, optional 1" NPTF Pressure Limit: 150 psi at 70 F ** Shell Materials: Polypropylene, PVC, PVDF Elastomers: Neoprene, Buna-N, EPDM, Viton, Hypalon, Teflon **Caution: Temperature and pressure affect the strength and chemical resistance of plastic and rubber. primary@primary fluid.com

4 ACCU-PULSE II Pulsation Dampeners Operation: ACCU-Pulse pulsation dampeners operate on the principal that volume is inversely proportional to pressure. Compressed air or gas is introduced into the top section of ACCU-Pulse to a specified pressure that must be lower than the pump's discharge pressure. When a pump or valve introduces a pulse, fluid enters the dampener and compresses the trapped gas. The fluid remains in the dampener until the system pressure returns to normal, when the valve is reopened or the pump begins its next cycle. The fluid is then pushed back into the system piping as the trapped gas expands. ACCU-Pulse does NOT restrict fluid flow, or increase system pressure. ACCU-Pulse fills the fluid voids and pressure fluctuations created by reciprocating pumps. Typical Installations: Dimensions: Parts Description: Item Part # Qty Description Material 1 * ^ 1 W etted Housing PVC * ^ W etted Housing GF Polypropylene * ^ W etted Housing PVDF Bladder Neoprene Bladder EPDM Bladder Buna-N Bladder Hypalon Bladder Viton Bladder Aflas Bladder Teflon 3A * NonW etted Housing PVC * NonW etted Housing GF Polypropylene Ring Band Assy GF Noryl Gauge Plastic / Brass Fill Valve Brass ^ add suffix -2 for units with 3/4" connections ^ add suffix -3 for units with 1" connections * add suffix T for Wetted & NonWetted Housing withteflon Bladders Recommended Spare Parts WA Distributed by: SA & NT VIC & TAS PRIMARY FLUID NSW & Call ACT Toll Free QLD (08) (08) (03) SYSTEMS INC. (02) (07) Tel: (905) Fax: (905) hydramet@hydramet.com.au hydrasa@hydramet.com.au hydravic@hydramet.com.au hydransw@hydramet.com.au hydraqld@hydramet.com.au Distribution Territories Available E:Mail: primary@primaryfluid.com Registered Trade Mark of Primary Fluid Systems 2 e

5 ACCU-PULSE III Pulsation Dampeners Chargeable / Plastic / Dome Top lightweight, compact design 300 psi rating extensive range of materials Technical Data FEATURES remove pulsating flows from positive displacement pumps increase system efficiency and pump life decrease maintenance and costs protect pipes, meters, instruments, valves, gaskets and seals from pulsation and vibration ensure meter accuracy, longevity and repeatability reduce pressure fluctations and diaphragm wear prevent foaming and splashing easy in-line maintenance 2 year warranty Unit Capacity: 370 CU In Weight: pounds Air Control: Gas Fill Valve Inlet Port: 2" NPTF Pressure Limit: 150 psi at 70 F ** Shell Materials: Polypropylene, PVC, PVDF Elastomers: Neoprene, Buna-N, EPDM, V iton, Hypalon, Teflon **Caution: Temperature and pressure affect the strength and chemical resistance of plastic and rubber. PRIMARY FLUID Call Toll Free SYSTEMS INC. Tel (905) Fax (905) primary@primary fluid.com

6 ACCU-PULSE III Pulsation Dampeners Operation: ACCU-Pulse pulsation dampeners operate on the principal that volume is inversely proportional to pressure. Compressed air or gas is introduced into the top section of ACCU-Pulse to a specified pressure that must be lower than the pump's discharge pressure. When a pump or valve introduces a pulse, fluid enters the dampener and compresses the trapped gas. The fluid remains in the dampener until the system pressure returns to normal, when the valve is reopened or the pump begins its next cycle. The fluid is then pushed back into the system piping as the trapped gas expands. ACCU-Pulse does NOT restrict fluid flow, or increase system pressure. ACCU-Pulse fills the fluid voids and pressure fluctuations created by reciprocating pumps. Typical Installations: Dimensions: Parts Description: Item Part # Qty Description Material W etted Housing PVC W etted Housing GF Polypropylene ^ W etted Housing PVDF Bladder Neoprene Bladder EPDM Bladder Buna-N Bladder Hypalon Bladder Viton Bladder Aflas Bladder Teflon 3A NonW etted Housing PVC ^^ NonW etted Housing GF Polypropylene Ring Band Assem bly GF Noryl Gauge Plastic / Brass F ill V alve B ras s ^ add suffix for W etted Housing and Teflon Bladder APIIIF only ^^ used with Polypropylene and PVDF units Recom m ended Spare Parts Distributed by: PRIMARY FLUID Call Toll Free WA SA & NT VIC & TAS SYSTEMS INC. NSW & ACT QLD Tel: (905) (08) (08) (03) (02) Fax: (07) (905) hydramet@hydramet.com.au hydrasa@hydramet.com.au hydravic@hydramet.com.au hydransw@hydramet.com.au hydraqld@hydramet.com.au E:Mail: primary@primaryfluid.com Distribution Territories Available Registered Trade Mark of Primary Fluid Systems e 19

ACCU-PULSE I Pulsation Dampeners

ACCU-PULSE I Pulsation Dampeners ACCU-PULSE I Pulsation Dampeners Chargeable / Metal / Dome Top FEATURES CRN is available on certain metallic units extensive range of materials lightweight, compact design Technical Data remove pulsating

More information

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS PULSATION / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS FUNCTIONS: 1. Pulsation Dampener smooths pump flow 2. Surge Suppressor absorbs shocks and vibrations 3. Water Hammer Arrestor eliminates

More information

ACCU-PULSE Installation and Operation Instructions

ACCU-PULSE Installation and Operation Instructions ACCU-PULSE Installation and Operation Instructions Pump Discharge Installation: Chargeable Models Step 1: Mounting Position Mount ACCU-PULSE as close to the pump discharge as possible to absorb the pulse

More information

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual TOP VALVE Pat. #5,857,486 & 5,944,050 Mid-Range Pressure 50 232 PSIG Back Pressure and Pressure Relief Valves Instruction Manual Please Note: This instruction manual provides detailed information and instructions

More information

Foreign language versions available online at:

Foreign language versions available online at: INSTALLATION & OPERATION MANUAL INLET STABILIZER DAMPENER ( J MODEL) SENTRY dampeners are pressure vessels containing a flexible bladder or bellows inside that separates an inert pressurized gas (air or

More information

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual TOP VALVE Pat. #5,857,486 & 5,944,050 High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves Instruction Manual PLEASE NOTE: This instruction manual provides information and instructions

More information

Installation and Operation Manual Chargeable Dampener Models

Installation and Operation Manual Chargeable Dampener Models Installation and Operation Manual Chargeable Dampener Models SENTRY dampeners are pressure vessels containing a flexible bladder or bellows inside that separates an inert pressurized gas (air or Nitrogen)

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual Chargeable Dampener Models SENTRY dampeners are pressure vessels containing a flexible bladder or bellows inside that separates an inert pressurized gas (air or Nitrogen)

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL DAMPENER (XPX HIGH PRESSURE MODEL) SENTRY dampeners are pressure vessels containing a flexible bladder or bellows inside that separates an inert pressurized gas (air or

More information

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Page 1 of 20 Page 2 of 20 TABLE OF CONTENTS Safety Warnings

More information

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified DataSheet Series AA Electronic Metering Pumps Configuration Data Model AA 9 4 1-358HI Control Code 1 --- Manual Control: Speed (stroking frequency) and stroke length manually adjustable. 7 --- Instrument

More information

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP This operating instructions contains safety information that if ignored can endanger life or result in serious injury. They are indicated by this icon. Use of this pump with radioactive chemicals is forbidden!

More information

Instruction presentation Special valves

Instruction presentation Special valves Instruction presentation Special valves 1 Special Valves 2 Special Valves Index of contents 1. Overview special valves 2. Description Gauge Guard 3. Description Water Jet Pumps 4. Description Venting and

More information

Precision and Instrument Regulators 1/4" port size

Precision and Instrument Regulators 1/4 port size Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38

More information

OPERATOR S MANUAL

OPERATOR S MANUAL OPERATOR S MANUAL 1604619 INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 11-1-13 REVISED: 3-03-14 (REV. B) 1/4" DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) 1604628 READ THIS MANUAL CAREFULLY BEFORE

More information

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 1.5 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF40 CLAMPED. A JDA Global Company

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 1.5 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF40 CLAMPED. A JDA Global Company OPERATION MANUAL 1.5 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF40 CLAMPED AIR-OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company CAUTIONS - READ FIRST CAUTION: Do not apply compressed

More information

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS OPERATION MANUAL 2 METALLIC PUMP (BOLTED) PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF50 AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company CAUTIONS - READ FIRST CAUTION:

More information

1200 Series Pressure Regulators

1200 Series Pressure Regulators SEE MORE AT SORInc.com Request Quote 1200 Series Pressure SOR pressure regulators are durable, high performing instruments that are designed to provide reliable control of pressure in various stages of

More information

Model PRS-07i. Stainless Steel Low Pressure, In-Line Pressure Regulator (Reducing Valve)

Model PRS-07i. Stainless Steel Low Pressure, In-Line Pressure Regulator (Reducing Valve) Phone (toll-free): (888) 380-9660 Phone (local): (973) 340-9955 Fax: (973) 340-9933 Web: www.straval.com 21 Columbus Avenue Garfield, NJ 07026 Model PRS-07i Stainless Steel Low Pressure, In-Line Pressure

More information

A050-1/2 INCH AIR OPERATED double DIAPHRAGM PUMP

A050-1/2 INCH AIR OPERATED double DIAPHRAGM PUMP A050 - /2 INCH AIR OPERATED double DIAPHRAGM PUMP A050 /2 Pump /2 Aluminum NPT or BSP Connections Zinc Plated Hardware Non-Metallic Muffler Suction Right / Discharge Right Standard Porting SPECIFICATIONS

More information

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8 and 1/4 PTF Port Sizes. Air line equipment. Air line equipment R Miniature Brass Body Regulator Water and Compressed Air Service 1/" and 1/" PTF Port Sizes Compact design, corrosion resistant construction Brass body with choice of plastic or brass

More information

Pressure Relief Valve DHV 718

Pressure Relief Valve DHV 718 Advantages frictionless components low maintenance low pressure increase up to fully opened valve constant low vibration controlling hermetically sealed by diaphragm for oscillating pumps for viscous media

More information

Operating Instructions

Operating Instructions Operating Instructions Multifunction Valve Contents Page Safety Instructions... 2 Unpacking... 2 Introduction... 2 Dimensions... 4 Installation...2-3 Description of Controls & Operation... 3 Page Helpful

More information

PILOT OPERATED PRESSURE VACUUM RELIEF VALVE MODEL 1660

PILOT OPERATED PRESSURE VACUUM RELIEF VALVE MODEL 1660 PILOT OPERATED PRESSURE VACUUM RELIEF VALVE MODEL 1660 Patent Protected Premium Seat Tightness to Set Pressure Snap or Modulating Valve Action Provides Ability to Meet Clean Air Act Requirements 600 TYPICAL

More information

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control Cash Valve Type G-4 Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases Issued - March 2001 CAVMC-0512-US-0609 ISO 9001 Certified Flow Control Description FIG 2042 - Bronze FIG 2043 - Bronze

More information

Best Practices for Installation of Gaseous Sample Pumps

Best Practices for Installation of Gaseous Sample Pumps Best Practices for Installation of Gaseous Sample Pumps Goal of the Gas Sample Pump Transport a clean, reliable, sample of the process gas to the analyzer, in the safest and easiest way possible, to ensure

More information

FAST & FLEXIBLE EXPERTISE 100% ORDER FULFILLMENT LOW COST PROVIDER

FAST & FLEXIBLE EXPERTISE 100% ORDER FULFILLMENT LOW COST PROVIDER FAST & FLEXIBLE JDA Global LLC (EST. 0) serves as the world s largest & most experienced after-market diaphragm pump products provider. We leverage our deeply embedded industry knowledge each day to bring

More information

MyControl Bathing System Signature Series

MyControl Bathing System Signature Series MyControl Bathing System Signature Series Touch Assist Touch Pad and CM Technologies Seal Pressure Regulation Instructions Acceptable seal inflation pressure setting must be varified, and adjusted if necessary,

More information

Booster Regulator/Air Tank

Booster Regulator/Air Tank Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed

More information

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified TYPE G-4 DESCRIPTION FIG 2042 - Bronze FIG 2043 - Bronze

More information

tel: fax: web:

tel: fax: web: Tri-Flex 2 Five-Cell Permeability Test System For high volume commercial laboratory testing, the Tri-Flex 2 Five-Cell Permeability Test System offers the user the capabilities to test up to five samples

More information

SERVICE & OPERATING MANUAL

SERVICE & OPERATING MANUAL SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP B15 & X15 Moulded Non-Metallic Series This pump is Atex approved for use in potentially explosive atmospheres Group II category 2 Table of

More information

Pressure Reducing Valve

Pressure Reducing Valve ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 D-32602 Vlotho Fon +49 (0) 57 33-7 99-0 Fax +49 (0) 57 33-7 99-2 00 www.asv-stuebbe.de contact@asv-stuebbe.de Advantages high reproducibility of setting pressure

More information

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications NT High-temperature flowmeter model 4401 Simultaneous flow and pressure outputs for high-temperature applications high-temperature flow measurement Overview Now more than ever there is a need to measure

More information

INDUSTRIAL TRANSFER PUMPS

INDUSTRIAL TRANSFER PUMPS INDUSTRIAL TRANSFER PUMPS Diaphragm Transfer Pumps - Plastic Body Pumps - Metal Body Pumps - Hygienic Pumps - High Pressure Pumps - Powder Pumps PLASTIC BODY PUMPS Diaphragm pumps also run trouble-free

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS For 3D Instruments Direct Drive Pressure Gauges 3D Instruments Inc., 15542 Chemical Lane, Huntington Beach, CA, 92649, U.S.A. Tel. (714) 894-5351, Fax. (714) 895-4309

More information

VACUUM REGULATORS CONTENTS

VACUUM REGULATORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate

More information

SERVICE & OPERATING MANUAL

SERVICE & OPERATING MANUAL SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP B06 AIR OPERATED DOUBLE DIAPHRAGM PUMP Non-Metallic 04 Series Table of Contents Service / Maintenance Log 2 Performance Curve 3 Dimensions

More information

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-07 REPLACES WIL E-06

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-07 REPLACES WIL E-06 P400/PX400 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11210-E-07 REPLACES WIL-11210-E-06 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

FILTER TYPE PRESSURE SNUBBER

FILTER TYPE PRESSURE SNUBBER FILTER TYPE PRESSURE SNUBBER Pressure oscillations and other sudden pressure changes can affect the delicate mechanisms of a pressure gauge or pressure transmitter. This can result in either complete failure

More information

S PRESSURE REGULATOR

S PRESSURE REGULATOR S PRESSURE REGULATOR SERVICE INFORMATION The "S" Pressure Regulator assures uniform air pressure in secondary pneumatic circuits. This three-way, self -relieving valve is versatile in its application and

More information

SERVICE & OPERATING MANUAL

SERVICE & OPERATING MANUAL SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP B06 & X06 Metallic Models 04 Series This pump is Atex approved for use in potentially explosive atmospheres Group II category 2 Table of Contents

More information

Air Operated Hydraulic Pumping Systems to 50,000 psi

Air Operated Hydraulic Pumping Systems to 50,000 psi High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air

More information

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot

More information

Model 4000 Pressure Controller

Model 4000 Pressure Controller FEATURES Multiple Configurations The 4000 series pressure controller can be configured into either proportional only or proportional plus reset mode with a minimum of parts. Rugged Design Die cast aluminum

More information

DEPA Air Operated Diaphragm Pumps

DEPA Air Operated Diaphragm Pumps DEPA Air Operated Diaphragm Pumps Series M Type DL Cast Metal Pumps DEPA air operated diaphragm pumps made of cast metal are the best suitable solution for most industrial applications. Many years experience

More information

PNEUMATIC PRESSURE CONTROLLERS

PNEUMATIC PRESSURE CONTROLLERS PNEUMATIC PRESSURE CONTROLLERS VARIABLE VOLUME PRESSURE CONTROLLER MODELS: V-1 R AND V-2R The 3D Variable Volume Pressure Controller is available for requirements of 0-1,000 psi and 0-6,000 psi in absolute

More information

GI Series Diaphragm Pressure Gauge Guard

GI Series Diaphragm Pressure Gauge Guard Diaphragm Pressure Gauge Guard INSTRUCTION MANUAL Please read this Instruction Manual Carefully and Thoroughly for the Correct and Optimum use of this Product. Kindly keep this manual in a convenient place

More information

P800/PX800. Advanced Series PLASTIC Pumps. Advance your process. Engineering Operation & Maintenance WIL E-04 TO REPLACE WIL E-03

P800/PX800. Advanced Series PLASTIC Pumps. Advance your process. Engineering Operation & Maintenance WIL E-04 TO REPLACE WIL E-03 P800/PX800 Advanced Series PLASTIC Pumps Engineering Operation & Maintenance Advance your process WIL-11250-E-04 TO REPLACE WIL-11250-E-03 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

2 I All-Flo Pump Co.

2 I All-Flo Pump Co. 2 I All-Flo Pump Co. 3I All-Flo Pump Co. Model Designation Matrix Pump Dimensions A B C D F H I J K L P300 18.90" 22.83" 31.50" 3.94" 15.28" 27.17" 1.57" 2.95" 15.55" 19.49" (480 mm) (580 mm) (800 mm)

More information

Choosing the right miniature instrument and control valve is a snap

Choosing the right miniature instrument and control valve is a snap Choosing the right miniature instrument and control valve is a snap INVALCO Micro Valve The Micro Valve is a unique miniature valve offering versatility and rugged construction. Since its introduction

More information

Pressure Reducing Valve DMV 750 set range: bar

Pressure Reducing Valve DMV 750 set range: bar Pressure Reducing Valve DMV 750 set range:.0-6.0 bar Advantage pressure setting possible at any time, also during operation hermetically sealed by valve diaphragm high level of operating safety and long

More information

SERVICE & OPERATING MANUAL

SERVICE & OPERATING MANUAL SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP B50 & X50 Moulded Non-Metallic Series This pump is Atex approved for use in potentially explosive atmospheres Group II category 2 Table of

More information

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information SIX R431006322 (P -063892-00001) AND SEVEN R431006321 (P -063981--00002) POSITION CYLINDERS Service Information The six and seven position cylinders are medium duty pneumatic positioning devices that operate

More information

B25 & X25 SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP Series 1 Models. II 2 GD c

B25 & X25 SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP Series 1 Models. II 2 GD c SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP B25 & X25 25 05 Series 1 Models This pump is Atex approved for use in potentially explosive atmospheres Group II category 2 This Manual covers

More information

Application and Sizing

Application and Sizing Application and Sizing Energy accumulator: It is improbable that an hydraulic system use all of its capacity without interruptions. An hydropneumatic accumulator can store a certain amount of fluid that

More information

OWNER S TECHNICAL MANUAL

OWNER S TECHNICAL MANUAL EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids,

More information

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

INSTALLATION, OPERATION AND MAINTENANCE GUIDE INSTALLATION, OPERATION AND Placement in Pipeline System When installing Process Development & Control s ElastoTITE Elastomer-Hinged Check Valves in a pipeline, a minimum of five pipe diameters should

More information

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps Operating Instructions Models 36454 and 364540 Hydrostatic Test Pumps 36454 DIMENSIONS: 24 (61cm) L x 19 (48cm) W x 19.5 (50cm) H WEIGHT: 135 lbs 61.5 kg PUMP: Twin piston: Positive displacement type Inlet

More information

Pressure Reducing Valve DMV 750

Pressure Reducing Valve DMV 750 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 D-32602 Vlotho Fon +49 (0) 57 33-7 99-0 Fax +49 (0) 57 33-7 99-2 00 www.asv-stuebbe.de contact@asv-stuebbe.de Pressure Reducing Valve DMV 750 Advantages reduction

More information

Corporation Stops Technical Bulletin

Corporation Stops Technical Bulletin Corporation Stops Technical Bulletin Available in ½", ¾", 1", 1¼", 1½", 2" Sizes The information contained in this manual was current at the time of printing. The most current versions of all Hydro Instruments

More information

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150, CARTRIDGE FILTERS Models: CF50, CF75, CF00, CF50, The installation of this product should be carried out by a qualified pool technician, following the installation instructions provided in this manual.

More information

Chlorinator. MODEL C-731 (Floor Mounted)

Chlorinator. MODEL C-731 (Floor Mounted) Chlorinator MODEL C-731 (Floor Mounted) CHLOROTECH Model C-731 is the advance technology Chlorinator designed to feed chlorine gas at a controlled rate. The flow rate of gas is maintained by constant positive

More information

Bladder Accumulators. General Information. Bladder Accumulators. Introduction. Accumulator Function. Why use a Bladder Accumulator?

Bladder Accumulators. General Information. Bladder Accumulators. Introduction. Accumulator Function. Why use a Bladder Accumulator? General Information Introduction Accumulator unction Bladder accumulators provide a means of regulating the performance of a hydraulic system. The design of the Stauff bladder accumulator makes use of

More information

Sizing Pulsation Dampeners Is Critical to Effectiveness

Sizing Pulsation Dampeners Is Critical to Effectiveness Sizing Pulsation Dampeners Is Critical to Effectiveness Pressure variation is an important consideration when determining the appropriate size pulsation dampener needed for an application. by David McComb,

More information

COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL

COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL SPECIFICATIONS: The CARD series air valves are available in 3 pipe sizes, 1, 2 and 4 NPT or socket. Maximum inlet pressure

More information

Pressure Reducing Valve DMV 755

Pressure Reducing Valve DMV 755 Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to

More information

FLOAT OPERATED LEVEL CONTROLLER

FLOAT OPERATED LEVEL CONTROLLER PNEUMATIC LEVEL SWITCH APPLICATION: Liquid level controller for oil and gas separators, water knockouts, gas scrubbers and accumulators. FEATURES: Rated for 2000 psi working pressure Push-button dump valve

More information

Instruction Manual. Standard Surge Eliminator. Standard X. Flushable X - X

Instruction Manual. Standard Surge Eliminator. Standard X. Flushable X - X Standard Surge Eliminator Standard 104052 - X Flushable 104053 - X - X Page 2 of 16 Issue: 2.3 Index Section 1.1 General Description 1.2 Operating Principle 1.3 Specification 1.4 Fitting Selection - Standard

More information

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE INSTRUCTIONS PARTS LIST 307 900 This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE STAINLESS STEEL (ASME) Pressure Tanks 100 psi (7 bar) Maximum Working Pressure with

More information

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

KDV HIGH ACCURACY GLASS TUBE ROTAMETER KDV HIGH ACCURACY GLASS TUBE ROTAMETER Flow Pressure Level Temperature measurement monitoring control S2 Industrial and Sanitary Designs Body Sizes 1/2 Through 2 Reliable, Time Proven Glass Tube Design

More information

Direct Operated Precision Regulator Modular Style. Standard Specifications

Direct Operated Precision Regulator Modular Style. Standard Specifications 1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com

More information

PRO-50 Instrument Supply Regulator

PRO-50 Instrument Supply Regulator Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits

More information

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900 Data Sheet Flow Controllers for Gas and Liquid Service Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900 Features and Benefits Flow controllers for high pressure

More information

FLOAT OPERATED LEVEL CONTROLLER

FLOAT OPERATED LEVEL CONTROLLER PNEUMATIC LEVEL SWITCH NO RELAY APPLICATION: Liquid level controller for oil and gas separators, water knockouts, gas scrubbers and accumulators. FEATURES: Push-button dump valve override standard Float

More information

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0 ir line equipment P1H, PTH Filter/Regulator- Lubricator Combination Units 07 Series Compact design Filter removes liquids and solid particles down to 5 µm Push to lock adjusting knob with tamper resistant

More information

Pocket Bellows Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

Pocket Bellows Pumps. 180 Hines Ave. Bellville, OH PH: FAX: Pumps models are ideal for low flow, low pressure metering applications. The pump is constructed entirely of plastic and utilizes GRI s time-proven bellows technology to provide an accurate chemically-resistant

More information

Technical Process Bulletin

Technical Process Bulletin Technical Process Bulletin RIDOLINE 53 Alkaline Immersion Cleaner 1. Introduction: Technical Process Bulletin No. 234242 This Revision: 23-11-1990 RIDOLINE 53 is a powdered, silicated, alkaline immersion

More information

EOM PX1500. Engineering Operation & Maintenance. Advanced Series Metal Pump. WIL E-10 Replaces WIL E-09

EOM PX1500. Engineering Operation & Maintenance. Advanced Series Metal Pump.  WIL E-10 Replaces WIL E-09 EOM Engineering Operation & Maintenance PX1500 Advanced Series Metal Pump W h e r e I n n o v a t i o n F l o w s. www.wildenpump.com WIL-11230-E-10 Replaces WIL-11230-E-09 TABLE OF CONTENTS SECTION 1

More information

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E Serie ECO T Threaded end back flow preventer with controllable reduced pressure zone BRANDONI made in E U R O P E Application fields WATER FIRE FIGHTING DRINKING WATER 74 www.brandoni.it Serie ECO T The

More information

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11 P400/PX400 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11210-E-12 REPLACES WIL-11210-E-11 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

Installation and Operating Instructions Bypass Flow Meter DST

Installation and Operating Instructions Bypass Flow Meter DST Installation and Operating Instructions Bypass Flow Meter DST DST_gb_A4_1.0.doc Version 1.0 1 von 10 Contents 1. Foreword... 3 2. Safety... 3 2.1. Symbol and meaning... 3 2.2. General safety directions

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN

More information

READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT

READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT User Manual for Models: 910 910K 910V 10 Gallon Portable Foam Unit 12142010 Hose...20 feet reinforced hose, 1/2 inch I.D. (6 meters reinforced hose, 13 mm I.D.) Foam output...15 to 30 gallons/minute (57

More information

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure

More information

ELADOS EDP L Diaphragm Metering Pump Type

ELADOS EDP L Diaphragm Metering Pump Type ELADOS EDP L Diaphragm Metering Pump Type 04800-06700 Motor-driven diaphragm pump with integrated frequency converter High reserves due to a powerful asynchronous motor High flexibility due to variably

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

SG3 Series Regulators - Pressure Reducing

SG3 Series Regulators - Pressure Reducing SG3 Series Regulators - Pressure Reducing DSG333X1 Specifications For questions about this product, please consult TESCOM. OPERATING PARAMETERS Pressure rating per criteria of CGA E-4; ASME B31; ASME BPVC

More information

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range

More information

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL. SERIES 30 PROTECTOSEAL 1 2" NPT inlet and outlet standard Direct acting valve mechanism Optional flanged or threaded inlet and outlet connections available Inlet gas pressures from 10 PSIG to 200 PSIG

More information

A CATALOUGE FOR Q B Y AIR OPERATION DIAPHRAGM PUMP. Factory Warranty. Food & Beverage. Mining. Paints & Dyes. Petrochemical.

A CATALOUGE FOR Q B Y AIR OPERATION DIAPHRAGM PUMP. Factory Warranty. Food & Beverage. Mining. Paints & Dyes. Petrochemical. Catalogue No. SIKO-QBY-003 A CATALOUGE FOR Q B Y AIR OPERATION DIAPHRAGM PUMP 1 Full Year Factory Warranty Food & Beverage Mining Paints & Dyes Petrochemical Pharmaceutical Pulp & Paper Power & Energy

More information

Flow Sensors & Hydrometers Specification Sheet

Flow Sensors & Hydrometers Specification Sheet Baseline Flow s and Hydrometers Baseline s smart flow sensors and hydrometers are two-wire ready flow measurement and control devices that are pre-programmed with the correct K and Offset values. In addition,

More information

Horizontal Bladder Tanks

Horizontal Bladder Tanks DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Test pumps. Pressure sources. Good reasons for proper and reliable calibration Test pumps Pressure is one of the most commonly measured quantities in engineering, which is why exact and reliable pressure measurement is especially important. However, the characteristics of the even

More information

P800/PX800. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11

P800/PX800. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11 P800/PX800 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11220-E-12 REPLACES WIL-11220-E-11 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

Model Series 62 Constant Differential Relay

Model Series 62 Constant Differential Relay Siemens Industry, Inc. INSTALLATION AND SERVICE INSTRUCTION INTRODUCTION Model Series 62 Constant Differential Relay Rev 11 March 2011 Supersedes Rev 10 The Constant Differential Relay maintains a constant

More information

Vertical Bladder Tanks

Vertical Bladder Tanks DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Diaphragm Accumulators

Diaphragm Accumulators Diaphragm Accumulators. DESCRIPTION.. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in HYDAC diaphragm accumulators

More information

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve Lower maintenance due to fewer parts Occupies less space, less stress to tank Teflon is inert to most chemicals; extends service life Simplifies and lowers maintenance cost Optimizes flow of blanketing

More information