Stator Resistance Thermometers
|
|
- Avis Lewis
- 5 years ago
- Views:
Transcription
1 Stator esistance hermometers
2 A complete solution for temperature sensing of electrical rotary machines
3 Simplex (Single element) stator winding Ds Model: SE series ( Single element) Extension eads ead ength C Product Overview he Stator winding temperature detector (D) are used to measure winding temperature of large Motors, Generators etc. hese sensor are sandwiched between the windings of Motors/Generators. Unlike on/off devices, It allows continuous measurement of winding temperature. he NEMA recognizes this kind of sensor as a standard protection for motor and generator Insulation. Normally, these Ds are of wire wound and sensing element extends through out the length of the detector. hese feature will provide average temperature reading. Normally six sensors are recommended for each motor, wo per Phase. his D are generally flat type in construction and are available in various sizes. Main Features Slim dimensions to get inserted in between windings Bifiliar design that prevents induction voltage resulting in measurement errors esistance to shock, vibration and pressure ithstand of VPI(Vacuum Pressure Impregnation) Process High Dielectric Strength AE /IECEx approve model available for equipment used in hazardous area MODE: SE-ACC----N-C-G-CC ACC Accuracy of D element (A/B/2B) ength in mm hickness in mm idth in mm N Nos. of wires (option 2/3/4) C ead length in mm G ire Gauge of lead wires in AG (option 22 to 28 AG) CC ead wire Construction (See table I) EAMPE (Part Number): SE-B Specification DIMENSIONA ANGE (IN MM) ype: Model: Element: P 100(100 ohm at 0 C)* SE and SF Single for SE series Double for SF series PAAMEE ENGH () HICKNESS () OEANCE +/-0.25 Body Material: emperature Class: Fibre Glass epoxy Class F(emperature limit:155 C) or Class H(emperature limit:180 C) IDH () EAD ENGH (C) /-0.20 Calibration Standard: IEC emperature coefficient(c): Accuracy: Class A/B/2B Sensing current: Dielectric strength: 10mA maximum 3 KV 50/60 Hz for 1 minute between leads and surface of Glass epoxy body (5 KV design are available on request) ABE 1 DESCIPION Number of wire: ead ire: wo or three or four Single or multiple stranded with in/silver/nickel plated copper wire with teflon or Polyamide insulation (special ead wire and cable upon request). Please note that the selection of suitable wire gauge is depend up on the width and thickness of the sensor. ISED EFON INSUAED / EFON JACKEED FA EFON INSUAED EADS (ithout Jacket) FA POAMIDE INSUAED EADS (ithout Jacket) FA EFON INSUAED AND JACKEED For Sizes & all other dimension please refer drawing. *Note: Other values like P-50,P-200 and temperature coefficient of are available upon request. Custom design of sensors are also available upon request. ISED EFON INSUAED /SHIEDED/ EFON JACKEED ** Patent apply
4 Duplex (Double element) stator winding Ds Model : SF series (Double Element) Extension eads ead ength C Product Overview Duplex stator winding D provide extra protection for Motors & Generator. he Second element is used either incase of damage of one element or use one element to display temperature at machine & second element for control room. Main Features Slim dimensions to get inserted in between windings Bifiliar design that prevents induction voltage resulting in measurement errors esistance to shock, vibration and pressure ithstand of VPI(Vaccum Pressure Impregnation) Process High Dielectric Strength AE /IECEx approve model available for equipment used in hazardous area Specification ype: Model: Body Material: emperature Class: P 100(100 ohm at 0 C)* SF series Fibre Glass epoxy Calibration Standard: IEC emperature coefficient (C): Accuracy: Sensing current: Dielectric strength: ead ire: Class F (emperature limit:155 C) or Class H (emperature limit:180 C) Class A/B/2B 10mA maximum 3 KV/50Hz for 1 minute between leads and surface of Glass epoxy body (Increased dielectric strength up to 5 KV/50Hz for 1 minute upon request.) 2/3/4 single or multiple stranded silver plated copper wire with PFE or Polyamide insulation(special ead wire and cable upon request).please note that the selection of suitable wire gauge is depend up on the width and thickness of the sensor. For Sizes & all other dimension please refer drawing. *Note: Other values like P-50,P-200 and D with C value etc. are available upon request. Custom design of sensors are also available upon request. ** Patent apply MODE: SF-ACC----N-C-G-CC ACC Accuracy of D element (A/B/2B) ength in mm hickness in mm idth in mm N Nos. of wires (option 2/3/4) C ead length in mm G ire Gauge of lead wires in AG (option 22 to 28 AG) CC ead wire Construction (See table I) EAMPE (Part Number): SF-B DIMENSIONA ANGE (IN MM) PAAMEE ENGH () HICKNESS () IDH () EAD ENGH (C) ABE 1 DESCIPION ISED EFON INSUAED /EFON JACKEED FA EFON INSUAED EADS FA POAMIDE INSUAED EADS FA EFON INSUAED AND JACKEED ISED EFON INSUAED /SHIEDED/ EFON JACKEED OEANCE
5 AE & IECEx approved Sensors Slot esistance hermometer Explosive Gas atmospheres (Increased safety e, Intrinsically safe i ) For SB and SC Series(Single element D) ead ength C Extension eads II 2G Ex e IIC Gb II 1G Ex ia IIC Ga MODE: SB-ACC----N-C-G-CC MODE: SC-ACC----N-C-G-CC Product Overview AE and IECEx sensors are intended for use in hazardous areas in which explosive gas atmospheres, caused by mixture of air and gases, vapours or mists, exist under normal atmospheric condition. Due to special design guidelines it prevents arcing. hese AE certified Ds are generally flat type in construction and are available in various sizes. Main Features Slim dimensions to get inserted in between windings Bifiliar design that prevents induction voltage resulting in measurement errors esistance to shock, vibration and pressure ithstand of VPI (Vaccum Pressure Impregnation) Process High Dielectric Strength D certified as Increase safety e and Intrinsically safe i approved for zone 1 and 21 EC-ype examination certificate no: DNV-2008-OS-AE-40059U, rev. 1 IECEx certificate no: IECEx DNV U and IECEx SI U complies with European standard for electrical apparatus for Explosive gas atmosphere : AE EU Directive 2014/34/EU IEC :2012 (General requirements) IEC :2015 (Increased Safety e ) IEC :2012 (Intrinsically Safe i ) Specification ype: Model: Element: P 100(100 ohm at 0 C) SB, SC, SD and SK series Single for SB, SC Series Double for SD series Both single and double for SK series Body Material: Fibre Glass epoxy (Class H) emperature ange: -50 C to +180 C Calibration Standard: IEC emperature coefficient (C): Accuracy: Sensing current: Dielectric strength: ead ire: Class A/B/2B 10mA maximum 3 KV/50Hz,1 minute, For SB series 5 KV/50Hz,1 minute, For SC and SK series 3 KV/50Hz,1 minute, For SD series 2/3/4 single or multiple stranded silver plated copper wire with PFE or Polyamide insulation ACC N C G CC EAMPE (Part Number): SB-B DIMENSIONA ANGE (IN MM) PAAMEE ENGH () HICKNESS () IDH () EAD ENGH (C) * FO 4 IE D MINIMUM IDH SAS FOM 7.5 MM ABE 1 DESCIPION ISED PFE INSUAED /PFE JACKEED FA PFE INSUAED EADS Accuracy of D element (A/B/2B) ength in mm hickness in mm idth in mm Nos. of wires (option 2/3/4) ead length in mm FA POAMIDE INSUAED EADS ire Gauge of lead wires in AG (option 22 to 28 AG) (See table I) FA PFE INSUAED AND JACKEED FA PFE INSUAED AND FEP JACKEED ISED PFE INSUAED /SHIEDED/PFE JACKEED 6.0 OEANCE +/ /-0.20 Q For Sizes & all other dimension please refer drawing.
6 SD Series (Double element) * For SK series: Extension eads Extension eads ead ength C ead ength C Heat Shrink Sleeve D MODE: SD-ACC----N-C-G-CC MODE: SK-E--ACC--D-N-C-G-CC ACC Accuracy of D element (A/B/2B) E ype of Element(P1=P-100 & P2=P-1000) ength in mm ype of D (S=Simplex & D=Duplex) hickness in mm ACC Accuracy of D element (A/B/2B) idth in mm ength in mm N Nos. of wires (option 2/3/4) D Diameter in mm C ead length in mm N Nos. of wires (option 2/3/4) G ire Gauge of lead wires in AG (option 22 to 28 AG) C ead length in mm CC (See table I) G ire Gauge of lead wires in AG (option 20 to 30 AG) CC (See table I) EAMPE (Part Number): SD-B DIMENSIONA ANGE (IN MM) EAMPE (Part Number): - SK-P1-S-A PAAMEE OEANCE DIMENSIONA ANGE (IN MM) ENGH () PAAMEE OEANCE HICKNESS () ENGH () /- 3.0 IDH () DIAMEE (D) /-0.5 EAD ENGH (C) EAD ENGH (C) ABE 1 ABE 1 DESCIPION DESCIPION ISED PFE INSUAED /PFE JACKEED ISED PFE INSUAED /PFE JACKEED FA PFE INSUAED EADS FA PFE INSUAED EADS FA POAMIDE INSUAED EADS FA PFE INSUAED AND JACKEED FA PFE INSUAED AND JACKEED ISED PFE INSUAED /SHIEDED/PFE JACKEED Q FA PFE INSUAED AND FEP JACKEED Q FA FEP INSUAED EADS ISED PFE INSUAED /SHIEDED/PFE JACKEED
7 Plot No. 54/1, Survey No. 299, Meladi Estate, Nr. Gota ailway Crossing, Gota, Ahmedabad , Gujarat, India. Mobile: elefax: , info@technocontrols.com
OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide
OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
More informationTechnical Data. Dimensions
0102 Model Number Features 6 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
More informationTechnical Data. Dimensions
0102 Model Number Features 10 mm flush Shielded PUR cable for oil and gas sector Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching function Normally closed (NC) Output type
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure
More informationTechnical Data. General specifications. Rated operating distance s n 2 mm
0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 2 mm Installation
More informationTechnical Data. Dimensions
00 Model Number Features Comfort series 30 mm non-flush Accessories MHW 0 Modular mounting bracket V-G Female connector, M, 4-pin, field attachable V-W-N-M-PUR Female cordset, M, -pin, NAMUR, PUR cable
More informationPressure switch, Differential pressure switch and Thermostat RT-E
Data sheet Pressure switch, Differential pressure switch and Thermostat RT-E The RT-E series consist of pressure and differential pressure switches as well as thermostats. The units are designed for industrial
More informationTechnical Data. Dimensions
00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationRelative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationOperating Instructions
Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 2 mm
0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-12 Quick mounting bracket with dead stop BF 12 Mounting flange, 12 mm Technical Data specifications Switching
More informationPressure Measurement Single-range transmitters for general applications
Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable
More information1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure
Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3
More informationPressure control, differental pressure control and thermostat Type RT
MAKING MODERN LIVING POSSIBLE Technical brochure Pressure control, differental pressure control and thermostat Type RT Hydrocarbons www.danfoss.com/hydrocarbons Contents Page Introduction...3 Approvals...3
More informationTechnical Data. Dimensions
0102 Model Number Features 2 mm flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI
Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 15 mm non-flush Stainless steel housing Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching element function NAMUR, NC Rated operating
More informationE10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.
> Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition
Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More informationATM.1ST/Ex - High Precision Transmitter
Pressure Transmitter - ATEX / IECEx certified ATM.1ST/Ex - High Precision Transmitter CUSTOMER BENEFITS Certificate: ATEX, IECEx & EAC High measurement accuracy is ensured by sophisticated digital temperature
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More informationE2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information
Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.
More informationATM.ECO/IS - Analog Transmitter with Temperature compensation
Pressure Transmitter - FM / FM-C certified ATM.ECO/IS - Analog Transmitter with Temperature compensation CUSTOMER BENEFITS Certificate: FM, FM-C & IECEx & ATEX Entry level series into precision pressure
More informationMagnetic level switch type MR783 Instruction Manual
Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 1.5 mm
0102 Model Number Features 1.5 mm flush Accessories BF 8 Mounting flange, 8 mm Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 1.5 mm Installation flush
More informationOperating Instructions
LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.
More informationIDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05
IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger
More informationGas density monitor With integrated transmitter Model GDM-100-TI
SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed
More informationDimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm
Dimensions M18x1 37 40 4 0102 24 LED Model Number Features 5 mm embeddable Usable up to SIL2 acc. to IEC 61508 Connection BN BU Accessories L+ L- EXG-18 Quick mounting bracket with dead stop BF 18 Mounting
More informationPressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview
f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationInductive slot sensor
0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Nonferrous targets Application Danger! In safety-related applications the sensor must be operated with a qualified fail
More informationDimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm
Dimensions M30x1,5 5 40 37 0102 Model Number 36 LED Features Comfort series 10 mm embeddable Connection BN BU Accessories BF 30 Mounting flange, 30 mm L+ L- Technical Data specifications Switching element
More informationLevel switches Series LD Vibrating fork level switch for liquids and solids
Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More informationWing Union/Hammer Union Pressure Sensors. Datasheet. Models 435/437
Wing Union/Hammer Union Pressure Sensors Models 435/437 0 psi to 5000 psi; 0 psi to 6000 psi; 0 psi to 10000 psi; 0 psi to 15000 psi; 0 psi to 20000 psi; 0 bar to 350 bar; 0 bar to 400 bar; 0 bar to 700
More informationL (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:
Smart level probe type APC-2000ALW/L Programmable zero shift, range and damping ratio 4...20 ma output signal + HART protocol Accuracy 0,16% Local display Intrinsic safety certificate (ATEX, IECEx) II
More informationTechnical Specifications
V200P Pneumatic Positioner Input range: 3-5 PSI 20-00 kpa Supply pressure: 45 PSI < MPa Linearity error:
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More informationLevel sensing relative and absolute pressure transmitter type 712
Level sensing relative and absolute pressure transmitter type 712 Pressure range 0... 0.3-3 bar The level sensing pressure transmitter Type 712 is manufactured using an relative or absolute pressure measuring
More informationHidrostatic Level DATASHEET
Hidrostatic Level DATASHEET JUNHO 2013 Hydrostatic level probes SGE-25 and SGE-16 SG cable hanger Red (+) Capillary Black ( ) PP junction box Any measurement range from 1 up to 500 m H 2 O Integrated internal
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationSafety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85
XA01537F-A/00/EN/01.16 71333275 Products Solutions Services Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 0Ex ia IIC T6 Ga X Ga/Gb Ex ia IIC T6 X Document: XA01537F-A Safety instructions
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationType N-10, N-11 Hazardous Area Non-incendive Transmitters
Electronic Pressure Catalog > Hazardous Area > N-10, N-11 Type N-10, N-11 Hazardous Area Non-incendive Transmitters Applications Natural gas compressors Wellhead monitoring Pipeline pressure General industrial
More informationGA24 Technical Datasheet
GA24 Technical Datasheet Variable-area flowmeter Sturdy construction for several applications Local indication without auxiliary power Replaceable mounting parts KROHNE CONTENTS GA24 1 Product features
More informationMechanical pressure switches
18 Technical features / Advantages Diecast aluminium housing IP 54 or IP 65 version also available Wall mounting or directly on the pressure line Switching element (microswitch) Lead sealable setpoint
More informationPressure switch KP-E. Data sheet
Data sheet Pressure switch KP-E KP-E pressure switches for use in refrigeration and air conditioning systems are equipped with SPDT gold plated contacts and stainless steel bellows. The high pressure switches
More informationLMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.
LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mho up to 0... 50 mho Output signals -wire: 4... 0 ma -wire: 0...
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up to SIL2 acc. to IEC 61508 Accessories
More informationDatasheet ANSI Standard Duplex Thermocouple Connector Sockets Types K, J, T, E, N, R/S & B (ANSI Colour Code)
Datasheet ANSI Standard Duplex Thermocouple Connector Sockets Types K, J, T, E, N, R/S & B (ANSI Colour Code) ENGLISH Duplex (2-channel) standard connector that accepts solid, round plug pins Bodies supplied
More information2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure
Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationLiquid level instruments BM 24 /BM 51
KROHNE 09/2001 7.02362.21.00 GR/PRINTO Liquid level instruments / Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters
More informationLevel transmitter LT 100
KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters
More informationLevel switches Series LD Vibrating fork level switch for liquids and solids
Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant
More informationRTD temperature probes
RTD temperature probes Ex i for use in areas with an explosion hazard (Ex areas) Persons concerned: Experienced professional electricians as per EU Directive 1999/92/EC and trained personnel Operating
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationCompact differential pressure switch Flameproof enclosure Ex d Models DE, DEC
Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring
More informationDMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.
Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:
More informationOperating Instructions
Operating Instructions Ex d Enclosures in Light Metal / Flameproof Encapsulation > 8265/0 Empty Enclosure > 8265/4 controller, installed in Ex e enclosure > 8265/5 controller Contents 1 Contents 1 Contents...2
More informationDM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More informationPRODUCT SPECIFICATION
MINI-FIT SR. SERIES 1.0 SCOPE This specification covers the 10.00 mm / (.394 in.) centerline tin and gold plated connector series, single and dual row versions in wire to wire and wire to printed circuit
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationSeries 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use
Data sheet Katharometers The ideal equipment for Process Monitoring and Control Designed for continuous industrial use Long working life Suitable for flammable gases CENELEC certified (ATEX) to EExia IIC
More informationPressure transmitters EMP 2
Data sheet Pressure transmitters EMP 2 The high accuracy pressure transmitter EMP 2 is designed for monitoring and control in marine and industial applications and offers a reliable pressure measurement,
More informationCertificate of Conformity
Certificate Holder: ABB Automation Products GmbH Schillerstrasse 72 D-32425 Minden GERMANY Electrical Apparatus: Type of Protection: 2600T Pressure Transmitter Models 265../267../269.. Communication protocols:
More informationUNIK 5600/5700 Marine Certified Pressure Sensing Platform
GE Measurement & Control UNIK 5600/5700 Marine Certified Pressure Sensing Platform The new UNIK 5600/5700 carries marine certification for most zones on-board ship, as well as Intrinsically Safe certifications.
More informationReg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS
Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS ZEST
More informationATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE
ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in
More informationDimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection
More informationENGLISH. Datasheet L60 Thermocouple & Fine Wire Welder
Datasheet L60 Thermocouple & Fine Wire Welder ENGLISH The Thermocouple Welder is a compact, simple-to-use instrument designed for thermocouple and fine wire welding It is primarily designed for use by
More informationPicture. Minimum cable bending radius 100 mm [4"] < 400 N [90 lbf] (PE / PUR cables) < 15 N [3.4 lbf] (FEP cables)
Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring
More informationGuide to Documentation and Marking Part 5 Lifting Accessories, Slings
Guide to Documentation and Marking Part 5 Lifting Accessories, Slings Document reference LEEA 059-5 version 1 dated 31.07.14 Introduction. This guide is aimed at manufacturers, distributors and users of
More informationDM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø
More informationLTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.
LTB013EN Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. to IECEx scheme Subject to technical modification Bachofen AG Ackerstrasse 42
More informationXMPA12B2142 pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type
Characteristics pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type Main Range of product Pressure sensor type Pressure sensor name Pressure sensor size OsiSense XM Electromechanical
More informationE8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)
Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless
More informationUltima. X Series Gas Monitor
Ultima X Series Gas Monitor Safety Manual SIL 2 Certified " The Ultima X Series Gas Monitor is qualified as an SIL 2 device under IEC 61508 and must be installed, used, and maintained in accordance with
More informationTechnical Explanation
Technical Explanation for ESI Pressure Sensors Technical Explanation What is a pressure transmitter? A pressure transmitter (also called pressure transducer or pressure converter) is a component used to
More informationDatasheet ANSI Type K & T Exposed Welded Tip Thermocouples (ANSI Colour Code)
Datasheet ANSI Type K & T Exposed Welded Tip Thermocouples (ANSI Colour Code) ENGLISH Thermocouple types K & T to ANSI MC96.1 Fast response, welded exposed junction 1, 2, 5 or 10-metre-long Teflon PFA
More informationMonitoring device NTS 30
P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit
More informationFlow Measurement SITRANS F C
Overview High-pressure program as standard The sensor calibration factor is also valid for gas measurement. SITRANS FC00 is a compact Coriolis mass sensor suitable for flow measurement of a variety of
More informationOperating Instructions of BROSA tension load cells, types 0111, 0113
Operating Instructions of BROSA tension load cells, types 0, 03. Description of BROSA tension load cells. Structure and function The BROSA type 0 and 03 tension load cells transmit and measure the tensile
More informationENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code)
ENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code) Miniature size in-line Thermocouple Socket with stainless
More informationETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More informationVG5 Supplementary instructions
VG5 Supplementary instructions 2-wire / 10 GHz Radar (FMCW) Level Meter Supplementary Instructions for ATEX applications HYCONTROL CONTENTS VG5 1 General safety information 4 1.1 Scope of the document...
More informationVA40 - VA45 Technical Datasheet
VA40 - VA45 Technical Datasheet Variable area flowmeter Local indication without auxiliary power Adaptable to meet customers' requirements Replaceable mounting parts KROHNE CONTENTS VA40 - VA45 1 Product
More informationTechnical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications
Technical Datasheet D Series SMART Pressure Transmitter Model: DPC-2000 Key Features ATEX - Flameproof and Intrinsically Safe IECEx - Flameproof and Intrinsically Safe SIL 2 certificate Compliant to NAMUR
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationAMT-Ex Dewpoint Transmitter
AMT-Ex Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk
More informationTechnical Explanation
Technical Explanation for ESI Pressure Sensors Technical Explanation What is a pressure transmitter? A pressure transmitter (also called pressure transducer or pressure converter) is a component used to
More informationENGLISH Datasheet IEC PTFE Exposed Welded Tip Thermocouples with Miniature Thermocouple Plug
ENGLISH Datasheet IEC PTFE Exposed Welded Tip Thermocouples with Miniature Thermocouple Plug Thermocouple types K, J & T Fast response, welded exposed junction 1, 2, 5 or 10 metre lengths available Teflon
More information1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS
1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS EXPLOSION PROTECTION In addition to the type approval and certification of industrial weighing systems concerned with accuracy, equipment that is also
More informationElectro-Pneumatic Converter YT-940 SERIES
Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product
More informationIECEx Certificate of Conformity
Certificate No.: IECEx KEM 09.0016 IECEx Certificate of Conformity Date of Issue: 2013-02-22 Issue No.: 3 Page 2 of 4 Manufacturer: Endress+Hauser GmbH+Co. KG Hauptstraße 1 79689 Maulburg Germany Additional
More informationAbout ABB Micafil Facts
About ABB Micafil Facts Location Zurich Employees ~ 200 Switzerland Revenues 2008 85 MUSD Production area 11 000 m 2 Export > 80%. About ABB Micafil History 1918 1939 1946 1960 1970 1972 1993 1996 1998
More informationAir Sensor. FCS Ex. Manual. AQ Elteknik AB
Air Sensor FCS Ex Manual AQ Elteknik AB Air Sensor Model FCS Ex Manual version 2.0 Oct 2010 AQ Elteknik AB AQ Elteknik AB Air Sensor Manual 2 Table of contents 1. Manufacturer information... 4 Manufacture
More information