Maintenance Made Simple Fewer replacement parts and super-simple disassembly make cleaning and maintaining the 7000 Series easy.

Size: px
Start display at page:

Download "Maintenance Made Simple Fewer replacement parts and super-simple disassembly make cleaning and maintaining the 7000 Series easy."

Transcription

1 Easy to Wear The 7000 Series half mask respirator is specifically designed to comfortably conform to facial contours and with a modern look that increases worker acceptance. The curved neck buckle and adjustable head cradle ensure a comfortable, custom fit for most users and without pressure points. Lightweight and Low Profile Workers will enjoy the all-day comfort that comes from the lightweight 7000 Series masks. The low profile, compact design provides an expansive field of vision and makes the mask well suited to be worn under welding helmets. Drop Down/Lock Down Strap In drop down mode the mask can be conveniently stored around the neck while on the go. Switch the strap to lock down position for quick donning of a mask pre-adjusted for personal comfort. Maintenance Made Simple Fewer replacement parts and super-simple disassembly make cleaning and maintaining the 7000 Series easy S E R I E S H A L F M A S K R E S P I R AT O R S Sleek design for modern, high-tech look and increased worker acceptance Lightweight design plus extra-wide sealing area provides all-day comfort Low profile, compact design fits well under welding helmets and with safety glasses Mask drops down for convenient storage around the neck or locks down for custom fit Adjustable head cradle and curved neck buckles for extra comfort Wide field of vision Maintenance made simple with very few replacement parts Available pre-assembled and also as individual components 00% PVC-Free Lock down mode Drop down mode

2 IMPORTANT NOTICE TO USERS You are responsible to understand and follow all warnings, restrictions and other information contained in the instruction manual before you enter a contaminated work area. Failure to do so may result in sickness or death. APPLICATIONS USE AGAINST. Contaminants specified on NIOSH approval label, matrix, cartridges or filters and in accordance with all limitations and applicable safety and health regulations, including OSHA.. Contaminants with good warning properties, i.e., smell, taste or irritation. DO NOT USE AGAINST. Concentrations of contaminants which are unknown, or are immediately dangerous to life or health.. Concentrations of contaminants which exceed the maximum use concentration or 0x the OSHA Permissible Exposure Limit, (PEL), whichever is lower, or according to applicable government regulations. 3. Gases or vapors with poor warning properties or those which generate high heats of reaction, or paint sprays containing isocyanates. 4. Sandblasting. 5. Oil-based mists with N filters. WARNINGS TO USER. Follow all instructions and warnings on the use of this respirator and wear during all times of exposure. Failure to do so will reduce respirator effectiveness, wearer protection, and may result in sickness or death.. For proper use, ask your supervisor or call. 3. The user must first be trained by the employer in proper respirator use, in accordance with applicable safety and health standards, for the contaminant and exposure level in the assigned work area. A written Respiratory Training Program must be in place and followed by each user before first use. It must meet all requirements of all applicable standards, including OSHA 9 CFR 90.34, and in Canada CSA Z 94.4, e.g. training, fit testing, medical evaluation, and applicable OSHA substance specific standards. 4. The vapors, gases, dusts, mists, fumes, and other contaminants which can be dangerous to your health include those which you cannot see, taste, or smell. 5. Check with your supervisor for the appropriate cartridges and/or filters for the contaminants in your work area. 6. A qualitative or quantitative fit test must be performed before a respirator is assigned. Refer to current OSHA 9 CFR (f). RESTRICTIONS. This respirator does not supply oxygen and must not be used in atmospheres containing less than 9.5% oxygen.. Do not remain in contaminated area if any physical distress occurs, for example breathing difficulty, dizziness or nausea. 3. Leave contaminated area and replace respirator and/or cartridge or filter if it is damaged, distorted, a proper fit cannot be obtained, you taste, smell or become irritated by contaminants, or breathing becomes difficult. 4. Do not alter, modify, or abuse this respirator. 5. Store respirator in sealed bag in a clean, dry, non-contaminated area. 6. Dispose of facepiece, and/or cartridges and disks/filters according to your employer s policy and applicable regulations. 7. N, R or P filters are required for particulates. 8. Where oil mists are present, either alone or in combination with solid particulates, do not use the R or P filters for longer than one eight-hour work shift. Dispose no later than eight hours after first use. Do not exceed 0x PEL or a total of 00 mg loading per respirator, whichever is lower. It is the user s responsibility to know the PEL and concentration of the contaminant, the maximum work rate of the employee, and any other work site-specific information to calculate the loading of the filter. Where oil mists are present do not use N filters. 9. Dispose of all cartridges and N filters no later than thirty days after a) first use, and/or b) removing from sealed bag. 0. Use cartridges, filters, and facepieces before the use by expiration date printed on box or bag. PACKAGING Product Code Description Sizes Display Case 700//3 Facepiece S, M, L per Bag Bags per Case 70//3 Organic Vapors S, M, L per Bag Bags per Case Pre-assembled Respirator 7//3 Oil-Free Paint Sptray/ S, M, L per Bag Bags per Case Pesticide Pre-assembled Respirator 77//3 Oil or Water-based S, M, L per Bag Bags per Case Paint Sptray/Pesticide Pre-assembled Respirator 760//3 Multi-Gas/Vapor Smart S, M, L per Bag Bags per Case Cartridges Pre-assembled Respirator 794//3 P00 S, M, L per Bag Bags per Case Pre-assembled Respirator LIMITED WARRANTY IMPORTANT NOTICE TO PURCHASER This limited warranty is made in lieu of the warranties of merchantability, fitness for particular purposes and all other warranties, express or implied. There are no other warranties which extend beyond the description on the face hereof. The physical standards and specifications of Moldex will be met by products sold. Exclusive Remedies: damages for the breach of this limited warranty are limited to the replacement of such quantity of Moldex products proved to be defectively manufactured. Except as provided above, Moldex shall not be liable or responsible for any loss, damage, or liability, direct, indirect, incidental, special, or consequential, arising out of sale, use, or misuse, or the inability to use products by the user.

3 7800 REUSABLE SILICONE RESPIRATORS The 7800 Premium Silicone Half Mask has higher resistance to heat and compression, with all the enhanced comfort and durability of silicone. PREMIUM COMFORT AND VALUE The 7800 Premium Silicone Half Mask is made of soft, supple silicone that conforms easily to different face shapes while maintaining a comfortable seal for protection you can count on. In addition, ease of use, minimum maintenance and economy make this premium silicone respirator a value choice. EASY TO WEAR The 7800 Premium Silicone Half Mask is designed to conform to facial contours and with a modern look to increase worker acceptance. The curved neck buckles and adjustable head cradle ensure a comfortable, custom fit for most users without pressure points. LIGHTWEIGHT AND LOW PROFILE Workers will enjoy the all-day comfort that comes from the lightweight 7800 Series Premium Silicone Half Mask. The low profile, compact design provides an expansive field of vision and makes the mask well suited to be worn under welding helmets. DROP DOWN/LOCK DOWN STRAP The 7800 Premium Silicone Half Mask can be conveniently stored around the neck in drop down mode when not in use. Switch the strap to lock down position for quick donning of a mask pre-adjusted for personal comfort. MAINTENANCE MADE SIMPLE Cleaning and maintenance of the 7800 Premium Silicone Half Mask couldn t be easier because of its super-simple disassembly and few replacement parts needed. FEATURES Soft Silicone facepiece feels supple on the face, yet firmly retains its shape. Sleek design for modern, high-tech look and increased worker acceptance. Light weight design plus extra-wide flexible face seal delivers all-day comfort. Low profile, compact design provides wide field of vision and fits well under welding helmets and with safety glasses. Mask drops down for convenient storage around the neck or locks down for custom fit. Adjustable head cradle and curved neck buckles for extra comfort. Maintenance made simple with very few replacement parts.

4 7800 REUSABLE SILICONE RESPIRATORS PART # / DESCRIPTION 780 Facepiece 780 Facepiece 7803 Facepiece SIZE Small Medium Large DISPLAY per Bag per Bag per Bag Case Bags Bags Bags IMPORTANT NOTICE TO USERS You are responsible to understand and follow all warnings, restrictions and other information contained in the instruction manual before you enter a contaminated work area. Failure to do so may result in sickness or death. WARNING TO USER. Follow all instructions and warnings on the use of this respirator and wear during all times of exposure. Failure to do so will reduce respirator effectiveness, wearer protection, and may result in sickness or death..for proper use, ask your supervisor or call 3. The user must first be trained by the employer in proper respirator use, in accordance with applicable safety and health standards, for the contaminant and exposure level in the assigned work area. A written Respiratory Training Program must be in place and followed by each user before first use. It must meet all requirements of all applicable standards, including OSHA 9 CFR 90.34, and in Canada CSA Z 94.4, e.g. training, fit testing, medical evaluation, and applicable OSHA substance specific standards. 4. The vapors, gases, dusts, mists, fumes, and other contaminants which can be dangerous to your health include those which you cannot see, taste, or smell. 5. Check with your supervisor for the appropriate cartridges and/or filters for the contaminants in your work area. 6. A qualitative or quantitative fit test must be performed before a respirator is assigned. Refer to current OSHA 9 CFR (f). APPLICATIONS USE AGAINST:. Contaminants specified on NIOSH approval label, matrix, cartridges or filters and in accordance with all limitations and applicable safety and health regulations, including OSHA.. Contaminants with good warning properties, i.e., smell, taste or irritation. DO NOT USE AGAINST:. Concentrations of contaminants which are unknown, or are immediately dangerous to life or health.. Concentrations of contaminants which exceed the maximum use concentration or 0x times the OSHA Permissible Exposure Limit, (PEL), whichever is lower, or according to applicable government regulations. 3. Gases or vapors with poor warning properties or those which generate high heats of reaction, or paint sprays containing isocyanates. 4. Sandblasting. 5. Oil-based mists with N filters. RESTRICTIONS: 0. This respirator does not supply oxygen and must not be used in atmospheres containing less than 9.5% oxygen. 0. Do not remain in contaminated area if any physical distress occurs, for example breathing difficulty, dizziness or nausea. 03. Leave contaminated area and replace respirator and/or cartridge or filter if it is damaged, distorted, a proper fit cannot be obtained, you taste, smell or become irritated by contaminants, or breathing becomes difficult. 04. Do not alter, modify, or abuse this respirator. 05. Store respirator in sealed bag in a clean, dry, non-contaminated area. 06. Dispose of facepiece, and/or cartridges and disks/filters according to your employer s policy and applicable regulations. 07. N, R or P filters are required for particulates. 08. Where oil mists are present, either alone or in combination with solid particulates, do not use the R or P filters for longer than one eight-hour work shift. Dispose no later than eight hours after first use. Do not exceed 0x PEL or a total of 00 mg loading per respirator, whichever is lower. It is the user s responsibility to know the PEL and concentration of the contaminant, the maximum work rate of the employee, and any other work site-specific information to calculate the loading of the filter. Where oil mists are present do not use N filters. 09. Dispose of all cartridges, N, R, P filters no later than thirty days after a) first use, and/or b) removing from sealed bag. 0. Use cartridges, filters, and facepieces before the use by expiration date printed on box or bag.

5 REUSABLE RESPIRATORS EASY TO WEAR

6 COMPLIANCE JUST GOT A WHOLE LOT EASIER Moldex designed the 7000 and 7800 half masks and 9000 full face series to be the most user friendly respirators on the market. These streamlined respirators feature fewer parts, minimal maintenance, and a wider field of vision. They are all ultra-light weight, durable, and economical, so maximum comfort with extended use is built-in. The award-winning 7000/7800/9000 series add up to simple, comfortable, and economical respiratory protection that s just plain EASY TO WEAR PREMIUM SILICONE HALF MASK The 7800 Premium Silicone Half Mask has higher resistance to heat and compression, with all the enhanced comfort and durability of silicone. NEW IN SILICONE 7000, 7800 and 9000 share a full line of cartridges and filters. Full range of gas/vapor cartridges for these common applications and environments: Foundries, paper, pesticides, wood products, printing, pharmaceuticals, agriculture, tobacco, mining, petrochemical, aluminum processing, textiles, glass, chemical manufacturing, paint, laboratories, utilities, cement, fiberglass, coal, fertilizer, petroleum refining, oil or water-based paints, electroplating, embalming, rendering, adhesives, construction, automotive, food processing, agriculture, mining, transportation industries, ship/boat building, health services, furniture manufacturing, primary and fabricated metal.

7 7000/7800 FEATURES Adjustable head harness for a custom fit Wide flange fits more facial shapes comfortably Compact, fits under welding helmets Low profile, angled cartridge placement for wider field of vision Contoured neck buckles for comfort and quick attachment Easy mount bayonet cartridge/filter attachment The versatile 7000/7800 has optional drop down/lock down strap modes Attached exhale cover for easy inspection 7000/ in Drop Down Mode Lock down mode Drop down mode Common applications and environments for 7940 P00 filter and 7990 P00 cartridge: For contaminants where an OSHA substance specific standard applies (asbestos, lead, cadmium, inorganic arsenic, MDA) requiring a High Efficiency Particulate Air (HEPA) filter as well as pharmaceutical, battery, nuclear, welding, metal processing. Also for use in environments where oil-based particulates are present.

8 9000 FEATURES Lightest weight facepiece of any popular model. Weighs less than 3 oz. Over-molded buckles for secure strap attachment. One finger strap release Stand away head harness for easy donning Completely free of metal parts Lens with scratch resistant coating meets ANSI Z87+ for impact protection. Tear away lens protector included Over-molded flange to lens. Eliminates heavy metal clamping frame for less weight and fewer parts Panoramic lens with peripheral vision side panels Integrated exhale area with attached cover. Fewer parts, simple maintenance and inspection Easy mount bayonet cartridge/filter attachment Common applications and environments for N95 and R95: Welding, grinding, machining, bagging, buffing, cement, metal working, dusty environments, foundry, mining, poultry, sanding, wood, furniture, textiles, waste processing. Always refer to instructions before using.

9 7000, 7800 AND 9000 FACEPIECES, CARTRIDGES, FILTERS & ACCESSORIES 7000, 7800 and 9000 Gas/Vapor and Particulate Cartridges 700 Organic Vapors 700 Acid Gases 7300 Organic Vapors/Acid Gases 7400 Ammonia/Methylamine 7500 Formaldehyde 7600 Multi-Gas/Vapor Smart Cartridgeridge 7990 P00 Particulates , 7800 and 9000 Particulate Filters Use 890 N95 or 8970 R95 Pre-Filter with the 700 Pre-Filter Retainer with any Gas/Vapor Cartridge. Use the 7940 P00 Filter Disk or 7950 P00 Filter Disk plus Nuisance OV/AG, or the 7960 P00 Filter Disk plus Nuisance OV as stand alone filters. Use the 7940 with the 790 Piggyback Adapter with any Gas/Vapor Cartridge. Use the 7999 Splash and Spark Disk Cover for filter protection P00 Filter Disk 7999 Splash and Spark Protector Cover 7950 P00 + Nuisance OV/AG Filter Disk 890 N95 Filter 7000, 7800 and 9000 Combo Stacked Cartridge/Filters 7960 P00 + Nuisance OV Filter Disk 8970 R95 Filter Pre-assembled Cartridge + Adapter + Filter for easy attachment. Optional replacement of either cartridge or filter, as needed, for optimum usage and cost savings. 740 Organic Vapor Cartridge/P Multi-Gas/Vapor Smart Cartridge/P , 7800 and 9000 Retainers and Accessories Product Display Case Code Description Quantity Quantity 7000 Series Half Mask Facepiece Half Mask, Small /Bag Bags Half Mask, Medium /Bag Bags Half Mask, Large /Bag Bags 7800 Series Premium Silicone Half Mask Facepiece Silicone Half Mask, Small /Bag Bags Silicone Half Mask, Medium /Bag Bags Silicone Half Mask, Large /Bag Bags 9000 Full Facepiece Full Facepiece, Small /Box Boxes Full Facepiece, Medium /Box Boxes Full Facepiece, Large /Box Boxes Gas/Vapor Cartridges 700 Organic Vapor Cartridges Pair/Bag 30 Bags 700 Acid Gas Cartridges Pair/Bag 30 Bags 7300 Organic Vapor/Acid Gas Cartridges Pair/Bag 30 Bags 7400 Ammonia/Methylamine Cartridges Pair/Bag 30 Bags 7500 Formaldehyde Cartridges Pair/Bag 30 Bags 7600 Multi-Gas/Vapor Smart Cartridges Pair/Bag 30 Bags Particulate Filters and Retainers * 890 N95 Particulate Filter 5 Pair/Bag 0 Bags * 8970 R95 Particulate Filter 5 Pair/Bag 0 Bags 7940 P00 Filter Disk Pair/Bag 30 Bags 7950 P00 Filter Disk with Nuisance OV/AG Pair/Bag 30 Bags 7960 P00 Filter Disk with Nuisance OV Pair/Bag 30 Bags 7999 Splash and Spark Protector Cover Pair/Bag 30 Bags 700 Pre-Filter Retainer Pair/Bag 50 Bags 790 Piggyback Adapter Pair/Bag 30 Bags 7990 P00 Cartridge Filters Pair/Bag 30 Bags Combo Stacked Cartridge/Filters 740 Organic Vapor/P00 Combo Cartridge/Filter Pair/Bag 30 Bags 7640 Multi-Gas/Vapor Smart Cartridge/P00 Pair/Bag 30 Bags Combination Cartridge/Filter Accessories and Replacement Parts Head Strap Assembly /Bag 0 Bags 0073 Diaphragms (7000/7800/9000) 0 Inhale 5 Exhale Kit 0074 Gaskets (7000/7800/9000) 0/Bag Bag Head Harness /Bag 5 Bags Faceshield Protector 5/Bag Bag M/L Nose Cup /Box 5 Boxes S Nose Cup /Box 5 Boxes Series Spectacle Kit /Box Box 7006 Probed Cartridge Kit (7000/7800/9000) /Kit Kit 700 Pre-Filter Retainer 790 Piggyback Adapter 0098 Spectacle Kit *890 N95 and 8970 R95 pre-filters can be used with 7000, 7800, 8000 and 9000 series respirators.

10 7000/7800/9000 REUSABLE RESPIRATORS FITTING INSTRUCTIONS AND SELECTION GUIDE 7000/7800 HALF MASKS AND 9000 FULL FACE MASK FITTING INSTRUCTIONS STANDARD LOCK DOWN MODE CARTRIDGES & FILTERS DROP DOWN MODE 700 Organic Vapor Cartridge 700 Acid Gas Cartridge Chlorine/Hydrogen Chloride/Sulfur Dioxide/or Chlorine Dioxide/or Hydrogen Flouride/or Hydrogen Sulfide. To lock the straps in position, open the valve cover by pulling up on the latch. Position straps underneath the tabs of the strap channel. Close and snap shut the valve cover. Open valve cover by pulling up on the latch. Pull the straps out from underneath the tabs of the strap channel. Close and snap shut the valve cover. Grab lower lengths of head harness with each hand, just above each adjustment buckle, and while positioning chin in flange, pull harness over the head Organic Vapor/ Acid Gas Cartridge Organic Vapors/Chlorine/Hydrogen Chloride/Sulfur Dioxide/Or Chlorine Dioxide/Or Hydrogen Fluoride/ Or Hydrogen Sulfide Ammonia/ Methylamine Cartridge First adjust head cradle then place respirator under the chin and pull the cradle to the top of the head so it rests on the crown. Attach the bottom straps directly against the back of your neck. Push facepiece onto face and chin with one hand and position for most comfortable and secure seal while pulling and tightening neck tab of harness with other hand. Repeat for other neck tab. For easiest, most secure and best fit, always adjust neck harness tabs first before tightening top harness tabs Formaldehyde Cartridge 7600 Multi-Gas/Vapor Smart Cartridge Attach the bottom straps directly against the back of the neck. Adjust head cradle then pull the cradle to the top of the head so it rests on the crown. PERFORM BOTH NEGATIVE AND POSITIVE SEAL CHECKS EACH TIME BEFORE ENTERING A CONTAMINATED AREA. Organic Vapors/Ammonia/Methylamine/ Chlorine/Hydrogen Chloride/Sulfur Dioxide/Or Chlorine Dioxide/ Or Hydrogen Fluoride/ Or Formaldehyde/Or Hydrogen Sulfide P00 Filter Cartridge Tighten top straps first then the lower neck straps until you have a very snug and leak-free fit. Facepiece should not be loose or slide up or down the nose. Tighten by pulling on ends or loosen by pushing out on buckle tab. Do not overtighten. Further tighten top straps if necessary. Tighten top straps first then the lower neck straps until you have a very snug and leak-free fit. Facepiece should not be loose or slide up or down the nose. Tighten by pulling on ends or loosen by pushing out on buckle tab. Do not overtighten. Further tighten top straps if necessary. Negative Pressure Seal Check: Cover both cartridges without pressing too hard against face, then gently inhale and hold your breath. The facepiece should slightly collapse. If air leakage is detected, re-adjust the position of the facepiece and the tension of head harness and repeat the seal check until leakage is eliminated P00 Filter Disk P00 plus Nuisance P00 plus Nuisance OV/AG Filter Disk OV Filter Disk PERFORM A NEGATIVE OR POSITIVE SEAL CHECK EACH TIME BEFORE ENTERING A CONTAMINATED AREA. 890 N95 Pre-Filter Negative Pressure Seal Check: Cover both cartridges without pressing too hard against face, and gently inhale and hold your breath. The facepiece should slightly collapse. If air leakage is detected, re-adjust the position of the facepiece and the tension of both headstraps and repeat the seal check until leakage is eliminated. Positive Pressure Seal Check: Cover the exhalation valve vent without pressing too hard against face, and exhale gently to create a slight positive pressure. If air leakage is detected, re-adjust the position of the facepiece and the tension of both headstraps and repeat the seal check until leakage is eliminated. Positive Pressure Seal Check: Cover the exhalation valve vent without pressing too hard against face, then exhale gently to create a slight positive pressure. If air leakage is detected, re-adjust the position of the facepiece and the tension of head harness and repeat the seal check until leakage is eliminated. 740 Organic Vapor Cartridge/ P00 Cartridge Disk 8970 R95 Pre-Filter 7640 Multi-Gas/Vapor Smart Cartridge/ P00 Cartridge Disk 7000/7800/9000 ACCESSORIES AND REPLACEMENT PARTS 700 Pre-Filter Retainer 790 Piggyback Adapter 7999 Splash/Spark Protector 700/780/900 Facepiece, Small 700/780/900 Facepiece, Medium 7003/7803/9003 Facepiece, Large WARNING: Before using these respirators, you must read manual for complete instructions. If you cannot obtain a proper fit, do not enter the contaminated area and see your supervisor. Follow all instruction and warnings on the use of this respirator and wear at all times of exposure. Failure to do so will reduce respirator effectiveness, wearer protection, and may result in sickness or death Replacement Parts: 007 Head Harness Assembly 0073 Diaphragm Kit 0074 Gasket Kit Moldex, Ideas that wear well and the PVC-Free logo are registered trademarks Replacement Parts: 0073 Diaphragm Kit 0074 Gasket Kit 009 Head Harness 0093 Face Shield Protectors 0094 Med./Large Nose Cup Assembly 0095 Small Nose Cup Assembly 0098 Spectacle Kit

11 FACEPIECE ONLY Description Model# Size Facepiece Assembly including Head Strap Harness and Inhale Exhale Valves S M L DISK/FILTER SERIES Description Model # Approval (7000) Approval (7800) N95 Particulates 890 Multiple Multiple R95 Particulates 8970 Multiple Multiple P00 Particulates 7940 Multiple Multiple P00 Particulates Plus Nuisance O.V./A.G TC-84A-6805 TC-84A-7457 P00 Particulates Plus Nuisance O.V TC-84A-574 TC-84A /7800 SERIES REPLACEMENT PARTS Description Model # Head Strap Assembly 007 Replacement Diaphragm Kit 0073 Replacement Gaskets for # See Separate (Matrix) Label for 4 CFR 84 NIOSH Approvals Refer to NIOSH label for approval limitations. Can only be used with all gas/vapor cartridges. Nuisance levels (less than OSHA PEL) RETAINERS/ADAPTERS Description Model # Retainer 700 Splash/Sparks Protector 7999 Piggyback Adapter 790 REPLACEMENT CARTRIDGES Description Model# Approval (7000) Approval (7800) Organic Vapor 700 TC-3C-50 TC-3C-3060 Acid Gases 700 TC-3C-5 TC-3C-306 Organic Vapors/ Acid Gases 7300 TC-3C-5 TC-3C-306 Ammonia/ Methylamine 7400 TC-3C-53 TC-3C-3063 Formaldehyde 7500 TC-3C-54 TC-3C-3064 Multi-Gas/Vapor Smart Cartridge 7600 TC-3C-59 TC-3C-3065 P00 Particulates 7990 TC-84A-590 TC-84A-7458 COMBO STACKED CARTRIDGES Description Model# Approval (7000) Approval (7800) Organic Vapor/P TC-84A-556 TC-84A-746 Multi-Gas Vapor/P TC-84A-55 TC-84A-75 Refer to NIOSH label for approval limitations. OSHA regulations require gas-proof goggles, when used against Formaldehyde. For use with #7940, #7950 and #7960 only, against splash/sparks. 3 3 TPE SILICONE LIST OF PARTS FOR 7000/ Small 700-Medium 7003-Large 780-Small 780-Medium 7803-Large Part# Description Inhale Diaphragm Exhale Diaphragm 007 Head Harness Assembly / Endoskeleton (inside mask) Fig. LISTA DE PARTES PARA MODELO 7000/ Pequeño 700-Mediano 7003-Grande 780-Pequeño 780-Mediano 7803-Grande Parte# Descripción Diafragma de inhalación Diafragma de exhalación 007 Conjunto de arnés de cabeza / Endoesqueleto (dentro de la mascara) LISTE DES PIÈCES POUR LE 7000/ Petit 700-Moyen 7003-Grand 780-Petit 780-Moyen 7803-Grand Pièce# Description Diaphragme inhalation Diaphragme expiration 007 Harnais pour la tête / L endosquelette (à l intérieur du masque) APPLICATIONS USE AGAINST. Contaminants specified on NIOSH approval label, matrix, cartridges or filters and in accordance with all limitations and applicable safety and health regulations, including OSHA.. Contaminants with good warning properties, i.e., smell, taste or irritation. DO NOT USE AGAINST. Concentrations of contaminants which are unknown, or are immediately dangerous to life or health.. Concentrations of contaminants which exceed the maximum use concentration or 0X the OSHA Permissible Exposure Limit, (PEL), whichever is lower, or according to applicable government regulations. 3. Gases or vapors with poor warning properties or those which generate high heats of reaction, or paint sprays containing isocyanates. 4. Sandblasting. 5. Oil-based mists with N filters. WARNINGS TO USER. Follow all instructions and warnings on the use of this respirator and wear during all times of exposure. Failure to do so will reduce respirator effectiveness, wearer protection, and may result in sickness or death..for proper use, ask your supervisor or call 3. The user must first be trained by the employer in proper respirator use, in accordance with applicable safety and health standards, for the contaminant and exposure level in the assigned work area. A written Respiratory Training Program must be in place and followed by each user before first use. It must meet all requirements of all applicable standards, including OSHA 9 CFR 90.34, and in Canada CSA Z 94.4, e.g. training, fit testing, medical evaluation, and applicable OSHA substance specific standards. 4. The vapors, gases, dusts, mists, fumes, and other contaminants which can be dangerous to your health include those which you cannot see, taste, or smell. 5. Check with your supervisor for the appropriate cartridges and/or filters for the contaminants in your work area. 6. A qualitative or quantitative fit test must be performed before a respirator is assigned. Refer to current OSHA 9 CFR (f). 7. This respirator facepiece, when combined with any nuisance level organic vapor and/or acid gas/particulate filter disk, may not be used for organic vapor or acid gas contaminants exceeding their respective OSHA Permissible Exposure Limit (PEL) or other government Occupational Exposure Limits (OEL), whichever is lower. Nuisance level refers to concentrations not exceeding the PEL or OEL, whichever is lower. RESTRICTIONS 0. This respirator does not supply oxygen and must not be used in atmospheres containing less than 9.5% oxygen. 0. Do not remain in contaminated area if any physical distress occurs, for example breathing difficulty, dizziness or nausea. 03. Leave contaminated area and replace respirator and/or cartridge or filter if it is damaged, distorted, a proper fit cannot be obtained, you taste, smell or become irritated by contaminants, or breathing becomes difficult. 04. Do not alter, modify, or abuse this respirator. 05. Store respirator in sealed bag in a clean, dry, non contaminated area. 06. Dispose of facepiece, and/or cartridges and disks/filters according to your employer s policy and applicable regulations. 07. N, R or P filters are required for particulates. 08. Where oil mists are present, either alone or in combination with solid particulates, do not use the R or P filters for longer than one eight-hour work shift. Dispose no later than eight hours after first use or 00 mg loading per respirator, whichever comes first. Do not exceed 0X PEL. It is the user s responsibility to know the PEL and concentration of the contaminant, the maximum work rate of the employee, and any other work site-specific information to calculate the loading of the filter. Where oil mists are present do not use N filters. 09. Dispose of all cartridges and N, R and P filters no later than thirty days after a) first use, and/or b) removing from sealed bag when used against non oil particulates. 0. Use cartridges, filters, and facepieces before the use by expiration date printed on box or bag.. If used for welding, wear appropriate eye and face protection. NIOSH CAUTIONS AND LIMITATIONS The following restrictions may apply. See NIOSH Approval Label. A. Not for use in atmospheres containing less than 9.5% oxygen. B. Not for use in atmospheres immediately dangerous to life or health. C. Do not exceed maximum use concentrations established by regulatory standards. H. Follow established cartridge change schedules to ensure that cartridges are replaced before breakthrough occurs. J. Failure to properly use and maintain this product could result in injury or death. L. Follow the manufacturer s User s Instructions for changing cartridges, and/or filters. M. All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other applicable regulations. N. Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer. O. Refer to User s Instructions, and/or maintenance manuals for information on use and maintenance of these respirators. P. NIOSH does not evaluate respirators for use as surgical masks. S. Special or critical User s Instructions and/or specific use limitations apply. Refer to User s Instructions before donning. FILTER DISKS FILTER DISK WITH PIGGYBACK ADAPTER/CARTRIDGE ASSEMBLY (Fig. 5) Before assembling filter disk #7940 to the piggyback adapter #790, inspect the sealing surface, to make sure it is clean and undamaged and the gasket is in place. (Fig. 4) Push the piggyback adapter onto the cartridge until it snaps into place all around the cartridge. To attach the cartridge to the facepiece, align the three cartridge notches with the three bayonets protruding from the facepiece and firmly turn clockwise until the cartridge is locked into position and is unable to turn any further. Check to see that it is seated properly, both on the inside and outside and flush against the facepiece. Inspect the piggyback adapter, sealing ring and gasket each time the filter disk is changed. If seal gasket is broken, cracked or damaged replace gasket or entire piggyback adapter. Insert filter disk into the piggyback adapter and turn clockwise until the filter disk is locked into position and is unable to turn any further and until both surfaces are tightly sealed together at all points. Check the inhalation diaphragms for dirt or damage and see that they are properly seated. (Fig., 3) Warning: Only use #790 piggyback adapter with the #7940 filter disks. Failure to do so may result in sickness or death. FILTER DISK SPLASH/SPARK PROTECTION (#7999) #7999 can be used with #7940, #7950 and #7960 filter disks. Push #7999 over filter disk until it snaps into place. (Fig. 6) FILTER DISK SERVICE LIFE Leave contaminated area and replace filters, disks or cartridges, if they become damaged, soiled, torn, or if you experience increased breathing resistance. Use Restrictions: Where oil mists may be present in the work area you must follow Restrictions #8, #9 and #0 for important restrictions on the use of these filters. FILTER DISK REPLACEMENT To remove the used #7940 filter disk, gently turn the filter disk counter clockwise and then remove it from the #790 piggyback adapter. Discard used filter disk. Then gently pull off the piggyback adapter. Inspect and clean the piggyback adapter each time the filter disk is changed. (Fig. 4) If seal gasket is worn, cracked or damaged, then replace gasket. If the piggyback adapter or sealing ring is worn or damaged, then entire adapter must be replaced. To remove the cartridge or filter disk, gently turn counter clockwise and remove from facepiece. Before replacing with a new cartridge or filter disk, inspect the facepiece to cartridge sealing surface, to make sure it is clean and undamaged. (Fig. 0) Only use replacement cartridges/filter disks from sealed bags. FILTERS FILTER ASSEMBLY Before assembling cartridges, inspect the facepiece sealing surface to make sure it is clean and undamaged. (Fig. 0) To attach the cartridge to the facepiece, align the three cartridge notches with the three bayonets protruding from the facepiece and firmly turn clockwise until the cartridge is locked into position and is unable to turn any further. Check to see that it is seated properly, both on the inside and outside and flush against the facepiece. Insert filter into the #700 retainer so that the side indicated is away from face. (Fig. 7) Check to see that filters are properly seated then push the retainer onto the cartridge until it snaps into place. Check the inhalation and exhalation diaphragms for dirt or damage and see that they are properly seated. (Fig., 3) FILTER REPLACEMENT To remove the old filter, gently pull off the filter retainer. Remove the old filter and place a new filter inside the retainer so that the side indicated is away from face. Inspect cartridge lid to be sure it is clean and undamaged. Replace the retainer. Warning: Use the #700 filter holder retainer with the #890 or #8970 filters only. Failure to do so may result in sickness or death. MAINTENANCE FACEPIECE SERVICE LIFE The effective life of the facepiece will be influenced by the use conditions and contaminants to which it is exposed. This includes concentration of the contaminants (e.g. ketones and aromatic solvents will increase the rate of deterioration), duration of exposure, ambient temperature, etc. Do not use solvents to wipe or clean the facepiece as these will reduce the life of the respirator and pose a health hazard to the user. If the material shows any signs of cracking, wrinkling, or aging, then discard the facepiece immediately. Do not expose to high ambient temperatures (above 60 F) as this will distort the facepiece, and may affect fit. CLEANING FACEPIECE ASSEMBLY Cleaning is recommended after each day s use or more frequently if necessary. Remove all filters, cartridges, inhalation & exhalation diaphragms from the facepiece. Push down and rotate counter clockwise the valve cover/head harness assembly including the straps and buckles to remove it from the mask completely. Gently scrub the facepiece with a soft brush in a mild germicidal detergent, rinse with clean water and air dry. Do not clean with solvents or expose to high temperatures. Inspect components, then reassemble and replace the exhalation diaphragm last. Replace entire respirator if worn, damaged or deformed. ENDOSKELETON The endoskeleton (Moldex part number ) may be used on either the 7800 Series Silicone Facepiece or the 7000 Series TPE Facepiece. The endoskeleton (Moldex part number ) must ONLY be used on the 7000 Series TPE Facepiece and NEVER on the 7800 Series Silicone Facepiece. INHALATION & EXHALATION DIAPHRAGMS INSPECTION/CLEANING Remove all three diaphragms to inspect. Two inhale diaphragms are located inside the facepiece and the exhale diaphragm is located under the valve cover. Open the valve cover by pulling up on the latch then remove the diaphragm. Clean and check the diaphragms for dirt, leaks, distortion, or any other damage. After washing and/or inspection, replace all three diaphragms and check to see that they are properly seated. WARNING When cleaning or sanitizing a respirator that has accumulated hazardous contaminants, the person doing the cleaning must wear the respiratory protection required to assure they will be protected from inhaling any hazardous contaminants on masks being cleaned. Caution should be exercised to assure such contaminants are not spread into respirable air, and that hazardous contaminants, when removed from the respirator, are properly disposed of. Failure to take these precautions could result in sickness or death, depending upon the contaminant. Check with your safety supervisor if you are unsure and always comply with all applicable workplace safety regulations including any substance specific standards. REPLACEMENT INSTRUCTIONS To remove valve cover/head harness assembly, first remove exhale diaphragm then push down on the cover/head harness assembly towards the facepiece turning the assembly counter clockwise and pull away from facepiece. To remove cartridge/filter holder from inside facepiece, first remove exhale and inhale diaphragms, then pull out and away from facepiece. Replace by aligning with holes in facepiece and fully engage. Replace valve cover/head harness assembly by aligning the notches with the bayonets protruding from the cartridge/filter holder, and twist/turn clockwise. Replace all diaphragms last. Caution: Do not twist the exhale cover. Twisting may result in separation from the exhale assembly. Do not use this facepiece without the exhale cover in place. REPLACEMENT PARTS Use only Moldex replacement parts for Moldex respirators. STORAGE CAUTION: When not in use or during storage, do not expose respirator to excessive heat (above 35 F / 57 C) or hazardous substances. Such exposure, or storing in any other manner that may also distort the facepiece, may prevent a proper fit and expose you to the risk of sickness or death. SUPPLEMENTAL HAZARD WARNINGS FOR MOLDEX PARTICULATE RESPIRATORS These are Warnings and Limitations that all users must be made aware of in addition to all warnings and other information on the outside of the Moldex respirator packaging or other published related information. You must read and comply with these Warnings and Limitations at all times and only when your employer has determined that it is appropriate to use this respirator. Proper use of this respirator may reduce but will not eliminate the risk of illness or death from exposure to some Chemical, Biological, Radiological, or Nuclear (CBRN) hazards. CBRN hazards include, but are not limited to, bacteria, toxins, and viruses that can cause death, serious bodily injury or disfigurement. The long-range and short-range risks of CBRN hazards and the amount and manner of exposure that may produce such risks remain to a great extent unknown. Use of this respirator must be in accordance with the Centers for Disease Control (CDC) Health Advisories or any other Local, State or Federal recommendations for use of respirators against specific CBRN hazards. This respirator should not be used for many CBRN hazards. There are more efficient models of respirators with a higher level of protection available from Moldex and other manufacturers. It is up to the employer, and not Moldex, to determine if a respirator should be worn and if so, which type, size, level of protection, and model. BACKGROUND The National Institute for Occupational Safety and Health (NIOSH), a branch of the CDC and a U.S. Government agency, is responsible for testing and certifying respirators for protection against hazardous industrial contaminants. Procedures for selecting and using proper respiratory protection are regulated by various governmental agencies, such as the Occupational Safety and Health Administration (OSHA). NIOSH tests and certifies certain respirators for use against chemical warfare agents, biological warfare agents or biohazards and provides advisory information for some biohazards, but OSHA and other government agencies have not set any exposure standards for these agents or biohazards, in general. Moldex does not make recommendations for any type of respirator to be used against CBRN hazards for workers or the general public. You should know that there may be no obvious warnings of the presence or release of CBRN hazards. WARNINGS FOR ALL USERS This respirator must only be used for substances having Permissible Exposure Limits (PELs) and only where deemed appropriate by your employer. This respirator must be fit tested. If you cannot obtain a proper fit, do not use the respirator and do not enter the risk area. This respirator is not for use with beards or other facial hair that prevents direct contact between the face and sealing surface of the respirator. Moldex respirators, when properly fitted and used as part of a comprehensive respiratory protection program, may reduce wearer exposure to some airborne hazards, but not all. In the event of a sudden or unexpected CBRN hazard release, you may use this respirator for escape only if you have not been provided with a more appropriate respirator for this type of situation. Do not remove the mask from the face until you have left the contaminated area. Do not reuse or store for reuse or hang around neck unless your employer specifically authorizes reuse. Dispose of respirator as a hazardous waste in accordance with your employer s directions. Use other personal protective equipment, as directed by your employer. Where appropriate use protective gloves when handling or removing respirator and dispose of respirator and then gloves in accordance with your employer s directions. If CDC or other Local, State or Federal agency issues new or revised guidelines for respirator use against specific hazards, users must strictly comply. WARNINGS FOR USE OF PARTICULATE RESPIRATORS AGAINST TB OSHA and CDC have recommended the use of any of the particulate respirators approved under 4CFR84 as a means of providing help in complying with a program designed to reduce occupational exposure to tuberculosis. The level of effectiveness of respiratory protection from tuberculosis cannot be determined with currently available data. However, proper use of appropriate Moldex respirators in conjunction with a comprehensive respiratory protection program may reduce, but will not eliminate, risk of infection. Be sure to read the Limitations outlined below and strictly follow all Warnings set forth under the WARNINGS FOR ALL USERS. When using any Moldex respirator, filter replacement and/or disposal must be handled in accordance with your Healthcare Facility s comprehensive respiratory protection program. If disinfectants are used to sanitize reusable facepieces, you must consult with your Healthcare Facility and run tests to ensure the compatibility of any disinfectant with Moldex reusable facepiece materials. Use of disinfectants could impair the efficiency of the respirator and result in a loss of protection. LIMITATIONS Respirators may reduce but do not eliminate wearer exposure to airborne hazards or the risk of contracting any disease or infection. Only use this respirator as part of a comprehensive respiratory protection program. You will receive no respiratory protection if this respirator is not properly fitted and worn. Additionally, potentially hazardous particles, including infectious agents, smaller than the particle sizes used in NIOSH certifications are likely to exist in certain environments. Some published data indicates that these smaller particles may not be filtered out as effectively as the particle sizes used by NIOSH [N Series Count Median Diameter (CMD) ±.0µm Geometric Standard Deviation.86 (GSD), and R and P Series CMD 0.85 ±.0µm.6 (GSD)] when certifying respirators. It is imperative that you determine the size and potential hazards of the particles that may be present in the environment before selecting appropriate respiratory protection, and that you refer to CDC guidelines when selecting and using any respirator, particularly in environments where smaller types of particles, such as those referenced above, may be present. If the respirator comes in contact with blood or fluids, including body fluids, leave contaminated area as soon as possible and discard and replace the respirator. Moldex respirators must not be used on children. LIMITED WARRANTY IMPORTANT NOTICE TO PURCHASER This limited warranty is made in lieu of the warranties of merchantability, fitness for particular purposes and all other warranties, express or implied. There are no other warranties which extend beyond the description on the face hereof. The physical standards and specifications of Moldex will be met by products sold. Exclusive Remedies: damages for the breach of this limited warranty are limited to the replacement of such quantity of Moldex products proved to be defectively manufactured. Except as provided above, Moldex shall not be liable or responsible for any loss, damage, or liability, direct, indirect, incidental, special, or consequential, arising out of sale, use, or misuse, or the inability to use products by the user. IMPORTANT NOTICE TO USERS You are responsible to understand and follow all warnings, restrictions and other information contained in this instruction manual before you enter a contaminated work area. Failure to do so may result in sickness or death. Moldex and Ideas that wear well are registered trademarks. U.S. Patents Pending. The PVC-Free logo is a trademark of Moldex-Metric, Inc. ENGLISH USER INSTRUCTIONS 7000/7800 Series Respirators User Instruction Manual DONNING PUTTING ON STANDARD LOCK DOWN MODE. To lock the straps in position, open the valve cover by pulling up on the latch. Position straps underneath the tabs of the strap channel. Close and snap shut the valve cover. (Fig. ). Adjust the head cradle size so that it rests comfortably on crown as needed. 3. Place respirator under the chin and pull the cradle to the top of the head so it rests on the crown. (Fig. 3) 4. Attach the bottom straps directly against the back of the neck. (Fig. 4) 5. Tighten top straps first then the lower neck straps until you have a very snug and leak-tight fit. Facepiece should not be loose or slide up or down nose. Tighten by pulling on ends or loosen by pushing out on buckle tab. Do not overtighten. Further tighten top straps if necessary. (Fig. 5) DROP DOWN MODE. Open valve cover by pulling up on the latch. Pull the straps out from underneath the tabs of the strap channel. Close and snap shut the valve cover.(fig. 6). Adjust the head cradle size so that it will rest comfortably on the crown as needed. 3. Attach the bottom straps directly against the back of your neck. (Fig. 4) 4. Then position the pre-adjusted head cradle on the crown. (Fig. 7) 5. Tighten top straps first then the lower neck straps until you have a very snug and leak-tight fit. Facepiece should not be loose or slide up or down nose. Tighten by pulling on ends or loosen by pushing out on buckle tab. Do not overtighten. Further tighten top straps if necessary. (Fig. 5) FIT TESTS A qualitative or quantitative fit test must be performed before a respirator is assigned. Refer to current OSHA 9 CFR (f). Qualitative fit testing can be performed using the Moldex BITREX fit test kit with appropriate cartridges or filters. Quantitative fit testing can be performed with probed cartridge kit. USER SEAL CHECK Perform both a negative and positive seal check each time before you enter a contaminated area. NOTE: When in use, remove the #7999 Splash/Spark Protector prior to performing the negative pressure seal check. Negative Pressure Seal Check: Cover both cartridges and gently inhale and hold your breath. The facepiece should slightly collapse. If air leakage is detected, re-adjust the position of the facepiece and the tension of both headstraps and repeat the seal check until leakage is eliminated. (Fig. 8) Positive Pressure Seal Check: Cover the exhalation valve vent and exhale gently to create a slight positive pressure. If air leakage is detected, re-adjust the position of the facepiece and the tension of both headstraps and repeat the seal check until leakage is eliminated. (Fig. 9) WARNING: If you cannot obtain a proper fit, do not enter the contaminated area and see your supervisor. Seal check your respirator each time before you enter and periodically while wearing the respirator in the contaminated area. It is the responsibility of the Safety Director or your supervisor to assist you in determining how tight the 7000/7800 Series respirators should be on the user s face. Prior to and during use the user has the final responsibility to determine how tight the respirator should be and when it needs to be adjusted to always maintain a proper seal. Do not over or under tighten as either may cause leakage and reduce protection. CARTRIDGE CHANGE OUT SCHEDULE WORKSHEET Duties / Job Classification: Location: CHEMICAL INFORMATION (FROM SDS OR MANUFACTURER) Chemical: Exposure Limit: Maximum Concentration: Boiling Point: Molecular Weight: Liquid Density: Vapor Pressure: Molecular Polarization: Refractive Index: WORKSITE CONDITIONS Maximum Expected Temperature (ºC): Expected Relative Humidity (%)*: Work Rate: Number of Shifts/Week: Hours Cartridge Used/Shift: DATA FOR #700 AND #7600 CARTRIDGES # of Cartridges: #700 Adsorbing Equivalent (grams): #700 & #7600 Cartridge Bed Height (cm): #7600 Adsorbing Equivalent (grams): #700 & #7600 Bed Diameter (cm): Service Life Estimate: Basis Used: Cartridge Change Out Schedule Every: Hours: After Each Shift: Other: This form may be used to assist you in developing a change out schedule when using #700 or #7600 cartridges for protection against organic vapors. Be advised, this is simply a tool to help you collect some of the pertinent data in developing a change out schedule. It is your responsibility to ensure the accuracy of the schedules that you develop for each operation and work site. *Moldex suggests that you use a range and use the lowest predicted breakthrough CARTRIDGES CHEMICAL CARTRIDGE SERVICE LIFE Leave contaminated area, and replace cartridges, if you smell, taste, or feel any irritation, in your nose or throat. Consult your supervisor. Replace according to your change out schedule per OSHA 90.34, or no more than eight hours after first use, or sooner if breakthrough occurs. CARTRIDGE/FILTER DISK ASSEMBLY First inspect the facepiece to cartridge or filter disk sealing surfaces to make sure it s clean and undamaged. Only use cartridges or filter disks from sealed bags. To attach the cartridge or filter disk to the facepiece, align the three cartridge or filter disk notches with the three bayonets protruding from the facepiece and firmly turn clockwise until the cartridge or filter disk is locked into position and is unable to turn any further (Fig. 0, ). Check to see that it is seated and flush against the facepiece. Then check the inhalation diaphragms for dirt or damage and see that they are seated properly. (Fig., 3) CHANGE OUT SCHEDULES OSHA (d) requires that the employer implement a change out schedule for cartridges based on objective information or data that will ensure cartridges are changed before the end of their service life (see OSHA for complete text). A cartridge s useful service life is how long it provides adequate protection from harmful chemicals in the air. The service life of a cartridge depends on many factors, including environmental conditions, breathing rate, cartridge filtering capacity and the amount of contaminants in the air. If you know what the chemical is and how much of it you are exposed to, then you are ready to estimate how long your respirator cartridges will work and apply the safety factor. You must use some type of objective data to develop a change out schedule. Options for determining a cartridge s service life include:. Conducting experimental tests.. Using a mathematical model OSHA has on its website other means of calculating breakthrough times for various chemicals. You may also wish to consider use of this website in developing your change out schedules. Be advised that actual service life can vary considerably from those calculated using these models. These models only provide rough estimates. Some of the data you will need specific to the Moldex cartridges in order to use the models on the OSHA website are: #700 has an average of 4.5 grams Organic Vapor Carbon, its height is.8 cm, inside diameter is 7.78 cm. #7600 has an absorbing equivalent of 36.0 grams Organic Vapor Carbon, its height is.8 cm, inside diameter is 7.78 cm. A change out schedule worksheet is provided. CARTRIDGE DETAILS READ THIS WARNING These weights were estimated by Miller-Nelson using methods based on their tests. It is suggested that you use default values provided by OSHA for the other cartridge specific parameters. Lastly, in order for the OSHA models to be used you may have to provide other pertinent data on the challenge agent which may be found on the SDS or from the chemical manufacturer. Moldex suggests that you use the OSHA models, or other means provided by OSHA. Moldex always recommends that you utilize the most conservative (shortest) breakthrough times. Fig. 5 Fig. Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 0 Fig. Fig. Fig. 3 Fig. 4 Fig. 6 Fig. 7 SELECTION GUIDE Use this Selection Guide to help you select the correct respirator and/or cartridges and/or filters for the contaminant in your work area. Check with your supervisor to determine if you have the correct protection. Refer to the NIOSH label for approval limitations. PRE INSPECTION Inspect your respirator before and after wearing. Do not wear, and return to your supervisor if:. Head straps are torn, cut, or have lost elasticity.. Buckles or head cradle are missing, damaged or broken. 3. Facepiece is cracked, torn, distorted, dirty, or has holes. 4. Inhalation/Exhalation diaphragms are missing, torn, damaged, or not properly seated. 5. Cartridges are at the end of their service life, cracked, damaged, or not properly seated. 6. Any other plastic part is cracked, distorted, or damaged. FITTING INSTRUCTIONS. Users must follow instructions each time respirator is worn.. OSHA regulation 9 CFR (f) requires that the user be fit tested. 3. Do not wear with any facial hair, such as beards, or any other facial features which may prevent a proper fit. 4. If you cannot obtain a proper fit, do not enter the contaminated area and see your supervisor. The Moldex 7000/7800 Series respirators can be worn in two different configurations, standard and drop down mode.

Maintenance Made Simple Fewer replacement parts and super-simple disassembly make cleaning and maintaining the 7000 Series easy.

Maintenance Made Simple Fewer replacement parts and super-simple disassembly make cleaning and maintaining the 7000 Series easy. Easy to Wear The 7000 Series half mask respirator is specifically designed to comfortably conform to facial contours and with a modern look that increases worker acceptance. The curved neck buckle and

More information

9000 SERIES FULL FACE RESPIRATORS

9000 SERIES FULL FACE RESPIRATORS Easy To Wear At less than 13 ounces, the 9000 Series respirator is ultra-lightweight. Workers will appreciate the comfort and longer wearability and employers will benefit from increased user acceptance.

More information

NIOSH CERTIFIED FEATURES DUAL APPLICATIONS SUITABLE FOR WELDING APPLICATIONS

NIOSH CERTIFIED FEATURES DUAL APPLICATIONS SUITABLE FOR WELDING APPLICATIONS NIOSH CERTIFIED N95 Particulate Filter Disk is NIOSH certified to have a filter efficiency level of 95% or greater against non-oil based particulate aerosols up to 10x PEL. Plus relief from nuisance levels

More information

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable User Instructions for 3M Organic Vapor Respirator, P95 Assembly 51P71/52P71/53P71 Important: Keep these User

More information

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable User Instructions for 3M Organic Vapor Respirator Assembly 5101/5201/5301; 3M Organic Vapor/Acid Gas Respirator Assembly 5103/5203/5303;

More information

T R A I N - T H E - T R A I N E R

T R A I N - T H E - T R A I N E R TRAIN-THE-TRAINER TABLE OF CONTENTS i. Introduction.....................................2 I. Before You Start..................................6 II. Moldex Technical Assistance........................7

More information

A. APPLICATIONS 1. WARNING TO USER

A. APPLICATIONS 1. WARNING TO USER IV. MOLDEX INDUSTRIAL 42 CFR 84 DISPOSABLE RESPIRATOR USER INSTRUCTIONS Each specific model may contain additional warnings and instructions. You MUST refer to the packaging for specific instructions.

More information

Filter cartridge protection class A2 Organic vapours, with boiling point above 65 C, to 50X OEL or 1000 ppm, whichever is the lower.

Filter cartridge protection class A2 Organic vapours, with boiling point above 65 C, to 50X OEL or 1000 ppm, whichever is the lower. 1 Star Mask paint spray respirator CHARACTERISTICS Star Mask is a respirator with exchangeable pre-filters and gas-filters. Star Mask protects against mist of paint, lacquer, enamel, pesticide, organic

More information

Phalanx Alpha Phalanx Beta and Ultra Elite

Phalanx Alpha Phalanx Beta and Ultra Elite Phalanx Alpha Phalanx Beta and Ultra Elite riot control agent gas masks instructions parts list NIOSH approved for respiratory protection in atmospheres containing CN and CS and particulates under the

More information

VFlex 9105/9105S Particulate Respirator N95

VFlex 9105/9105S Particulate Respirator N95 VFlex 9105/9105S Particulate Respirator N95 User Instructions IMPORTANT: Keep these User Instructions for reference 3M and VFlex are trademarks of 3M Company, used under license in Canada 98-0060-0156-8/2

More information

Particulate Respirator N95

Particulate Respirator N95 Particulate Respirator N95 9210+/*37192, 9211+/37193* User Instructions IMPORTANT: Keep User Instructions for reference *37192 and 37193 are catalog numbers only. NIOSH approved as 3M Particulate Respirator

More information

UltraFilter. respirator. with Ultravue or Ultra Elite Facepiece. instructions for use and care

UltraFilter. respirator. with Ultravue or Ultra Elite Facepiece. instructions for use and care 818188_b.qxd 2/20/01 7:38 AM Page 1 UltraFilter respirator with Ultravue or Ultra Elite Facepiece instructions for use and care This booklet, including the warnings and cautions inside, must be read and

More information

3M recommended for the aluminum industry and nuisance level acid gas relief* in non-oil environments User Instructions (Keep insert for reference)

3M recommended for the aluminum industry and nuisance level acid gas relief* in non-oil environments User Instructions (Keep insert for reference) 8516 Respirator N95 Particulate 3M recommended for the aluminum industry and nuisance level acid gas relief* in non-oil environments User Instructions (Keep insert for reference) *3M recommended for relief

More information

8200/07023 Particulate Respirator N95

8200/07023 Particulate Respirator N95 8200/07023 Particulate Respirator N95 User Instructions (Keep these User Instructions for reference) 07023 is a catalog number only. NIOSH approved as 3M TM 8200 Particulate Respirator N95. See insert

More information

9210/37021, 9211/37022* Particulate Respirator N95

9210/37021, 9211/37022* Particulate Respirator N95 9210/37021, 9211/37022* Particulate Respirator N95 User Instructions (Keep insert for reference) *37021 and 37022 are catalog numbers only. NIOSH approved as 3M 9210 N95 Particulate Respirator and 3M 9211

More information

8210Plus/8210/07048/8110S Particulate Respirator 3M recommended for sanding, grinding, sawing, sweeping and insulating

8210Plus/8210/07048/8110S Particulate Respirator 3M recommended for sanding, grinding, sawing, sweeping and insulating 8210Plus/8210/07048/8110S Particulate Respirator 3M recommended for sanding, grinding, sawing, sweeping and insulating User Instructions (Keep these instructions for reference) 1 This respirator helps

More information

8214/8514/07187 Respirator N95 Particulate

8214/8514/07187 Respirator N95 Particulate 8214/8514/07187 Respirator N95 Particulate 3M recommended for welding on stainless steel, aluminum, galvanized steel, and other applications where ozone and nuisance organic vapors* may be present. User

More information

3 8210Plus/8210/8110S Particulate Respirator User Instructions (Keep these instructions for reference)

3 8210Plus/8210/8110S Particulate Respirator User Instructions (Keep these instructions for reference) DO-IT-YOURSELF / HOMEOWNER USER INSTRUCTIONS 3 8210Plus/8210/8110S Particulate Respirator User Instructions (Keep these instructions for reference) This respirator contains no components made from natural

More information

University of Alabama Office of Environmental Health and Safety. Respirator Protection Training

University of Alabama Office of Environmental Health and Safety. Respirator Protection Training University of Alabama Office of Environmental Health and Safety Respirator Protection Training Medical Reasons That Could Prohibit the Use of a Respirator A history of pulmonary or lung problems such as:

More information

8000 SERIES FACEPIECE ASSEMBLY FACEPIECE REPLACEMENT CARTRIDGES 1 ORGANIC VAPORS ACID GASES ORGANIC VAPORS/ ACID GASES AMMONIA/METHYLAMINE

8000 SERIES FACEPIECE ASSEMBLY FACEPIECE REPLACEMENT CARTRIDGES 1 ORGANIC VAPORS ACID GASES ORGANIC VAPORS/ ACID GASES AMMONIA/METHYLAMINE 8000 REPIRATOR EECTION GUIDE 8000 ERIE FACEPIECE AEBY DECRIPTION PACKAGING ODE # IZE FACEPIECE Includes head strap assembly and exhale valve assembly. Facepiece/Bag 2 Bags/Case 800 8002 8003 REPACEENT

More information

Respirator Fit Testing DEPARTMENT OF LABOR Information on the Requirements Types of Respirators & Filters

Respirator Fit Testing DEPARTMENT OF LABOR Information on the Requirements Types of Respirators & Filters UNITED STATES Respirator Fit Testing DEPARTMENT OF LABOR Information on the Requirements Types of Respirators & Filters This information is about the respirator fit testing requirements for any worker

More information

8515/07189 Respirator. N95 Particulate 3M recommended for welding, brazing, metal pouring and cutting User Instructions (Keep insert for reference)

8515/07189 Respirator. N95 Particulate 3M recommended for welding, brazing, metal pouring and cutting User Instructions (Keep insert for reference) 8515/07189 Respirator N95 Particulate 3M recommended for welding, brazing, metal pouring and cutting User Instructions (Keep insert for reference) 07189 is a catalog number only. NIOSH approved as 3MTM

More information

Nuisance level organic vapor relief* User Instructions (Keep insert for reference)

Nuisance level organic vapor relief* User Instructions (Keep insert for reference) 8577 Respirator P95 Particulate Nuisance level organic vapor relief* User Instructions (Keep insert for reference) *3M recommended for relief against nuisance levels of organic vapor. (Nuisance level organic

More information

3M Half and Full Facepiece Respirators. Unsurpassed comfort. Maximum versatility. 3Innovation

3M Half and Full Facepiece Respirators. Unsurpassed comfort. Maximum versatility. 3Innovation 3M Half and Full Facepiece s Unsurpassed comfort. Maximum versatility. 2 1 3 4 5 3Innovation 3M Half Facepiece s Ultimate reusable for comfort and durability New 3M Half Facepiece s 7500 Series Ultimate

More information

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451.

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451. Calvin College Respiratory Protection Program Prepared by: Date: Heather Chapman 10/7/10 Approved by: Cabinet Revision 2 Date: 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory

More information

low maintenance respirator

low maintenance respirator low maintenance respirator instructions This booklet, including the warnings and cautions inside, must be read and followed carefully by all persons who use or maintain this product, including those who

More information

Head Cover BE-12 Series

Head Cover BE-12 Series Head Cover BE-12 Series User Instructions for 3M Head Covers BE-12, BE-12L, BE-12B and BE-12LB (Keep these User Instructions for reference) This product helps protect against certain airborne contaminants.

More information

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING Leader s Guide 2007 ERI Safety Videos THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING This easy-to-use Leader s Guide is provided to assist

More information

Respiratory Protection. Program

Respiratory Protection. Program Respiratory Protection Program Respiratory Protection Program Table of Contents A. General B. Selection of Respirators C. Medical Screening D. Fit Testing E. Respirator Use Instructions F. Respirator Inspection

More information

Respiratory Protection

Respiratory Protection Respiratory Protection Everything You Wanted to Know About Respiratory Protection and Probably a Bit More. Instructor: Mary Schlagel Northern Illinois University Environmental Health & Safety Dept. 815-753-0404

More information

Breathe easily. Weld safely. 3M Disposable and Reusable Respirators for Welding

Breathe easily. Weld safely. 3M Disposable and Reusable Respirators for Welding 3M Disposable and Reusable Respirators for Welding Breathe easily. Weld safely. Comfortable, low-profile disposable and reusable respirators compatible with 3M Speedglas welding helmets.* * Since head

More information

RESPIRATOR HALFMASK AIR-PURIFYING 7700 SERIES SILICONE HALF MASK CARRY BAG. features and benefits

RESPIRATOR HALFMASK AIR-PURIFYING 7700 SERIES SILICONE HALF MASK CARRY BAG. features and benefits 6 SILICONE HALFMASK AIR-PURIFYING RESPIRATOR 7700 SERIES SILICONE HALF MASK The 7700 Series is the most comfortable and durable half mask available. Its soft nonallergenic silicone seal provides excellent

More information

3 Choosing the Right Respirator

3 Choosing the Right Respirator 3 By: Jeanne Bidwell 3M Occupational Health and Environmental Safety Division Originally published February, 1997 for Plant Engineering Magazine Selecting respirators to help protect workers from airborne

More information

Entry to these spaces must be rigorously controlled to prevent serious injury or death.

Entry to these spaces must be rigorously controlled to prevent serious injury or death. Chapter 6 - Confined Spaces Chapter 6 Confined Spaces Definitions A confined space is defined as any structure that must be entered and that has or may contain dangerous concentrations of hazardous gases

More information

A. Evaluation of the written program

A. Evaluation of the written program A. Evaluation of the written program Begin your audit with an evaluation of the written respiratory protection program. In addition to the operating procedures describing respirator selection and use in

More information

SOTR Special Operations Tactical Respirator

SOTR Special Operations Tactical Respirator SOTR Special Operations Tactical Respirator OPERATOR S MANUAL FOR INDIVIDUAL RESPIRATORY PROTECTION OPS-CORE 2018 OMM G055-1000 REV. B INTRODUCTION ABOUT YOUR SOTR The Ops-Core Special Operations Tactical

More information

BREATHE SAFELY: The Proper Use of Respiratory Protection

BREATHE SAFELY: The Proper Use of Respiratory Protection BREATHE SAFELY: The Proper Use of Respiratory Protection This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION: A brief description of

More information

Technical. Datasheet. 3M 6000 Series Reusable Full Face Masks. Applications. Product Description. Key Features

Technical. Datasheet. 3M 6000 Series Reusable Full Face Masks. Applications. Product Description. Key Features Technical Datasheet 3M 6000 Series Reusable Full Face Masks Product Description 3M 6000 Series Reusable Full Face Masks are proven to be simple to handle and comfortable to the wearer. The new exhalation

More information

Respiratory Protection Self Inspection Checklist

Respiratory Protection Self Inspection Checklist Optional Information Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: Respiratory Protection Self Inspection Checklist Guidelines: This checklist covers some

More information

Respiratory Protection for Producers

Respiratory Protection for Producers March 2005 Agdex 086-8 Respiratory Protection for Producers Dust and harmful gases can cause immediate and long-term respiratory problems. Wearing protective equipment is vitally important when working

More information

Respiratory Protection

Respiratory Protection Respiratory Protection Purpose The purpose is to establish a set of guidelines for the selection of respiratory protection equipment, situations for its use, and training in the use of the respirator required.

More information

Respiratory Protection Program

Respiratory Protection Program California State University, Chico Department of Environmental Health and Safety Table of Contents Section 1.0 Introduction... 1-1 2.0 Responsibilities... 2-1 2.1 Environmental Health and Safety Responsibilities...

More information

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Respiratory Protection Policy 03/20/15 Last Revision

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Respiratory Protection Policy 03/20/15 Last Revision FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Respiratory Protection Policy 03/20/15 Last Revision 1.0 Intent: 2.0 Scope: It is the intention of the University at Albany to provide a

More information

RESPIRATORY PROTECTION PROGRAM

RESPIRATORY PROTECTION PROGRAM A P P E N D I X 14 RESPIRATORY PROTECTION PROGRAM AP14.1. Purpose. AP14.2. Policy. To establish a written Respiratory Protection Program for CBP. The purpose of an effective respirator program is to provide

More information

Respiratory Protection Self-Inspection Checklist

Respiratory Protection Self-Inspection Checklist Respiratory Protection Self-Inspection Checklist Guidelines: This checklist applies to the use of either atmosphere-supplying or air-purifying respirators being worn, voluntarily or otherwise, for comfort

More information

Ontario Operations PMP - Daily Safety Message. Respirator Safety

Ontario Operations PMP - Daily Safety Message. Respirator Safety Ontario Operations 2017 PMP - Daily Safety Message Respirator Safety Context: Respirators only work when they are selected, maintained, and used properly. Respirator Types, Fit and Maintenance: There are

More information

Respiratory Protection Training

Respiratory Protection Training Respiratory Protection Training Disclaimer IMPORTANT NOTICE: This risk control training program provided by PMA Companies is intended to help support your loss prevention efforts. It is not intended to

More information

Respiratory Protection

Respiratory Protection Respiratory Protection The 3M Four-Step Method What issues do we need to consider to get the correct respiratory protection? 1.Identify Respiratory Hazards 2.Understand the Contaminants Effect on Workers

More information

Respiratory Protection Program 29CFR

Respiratory Protection Program 29CFR Respiratory Protection Program 29CFR1910.134 Program Objectives OSHA requires employers to establish and implement procedures for the proper use of respirators by doing the following: Verify the need for

More information

3M Occupational Health and Environmental Safety Division. Options

3M Occupational Health and Environmental Safety Division. Options 3M Occupational Health and Environmental Safety Division 3M Respiratory Options During times of global and/or localized influenza outbreaks, available supplies of certain respirators can become constrained.

More information

Protective device that covers the nose and mouth or the entire face or head to guard the wearer against hazardous atmospheres

Protective device that covers the nose and mouth or the entire face or head to guard the wearer against hazardous atmospheres Protective device that covers the nose and mouth or the entire face or head to guard the wearer against hazardous atmospheres Working in an area with insufficient oxygen Situations where harmful dusts,

More information

In addition to the responsibility for managing the elements of the respiratory protection program, he/she will be responsible for:

In addition to the responsibility for managing the elements of the respiratory protection program, he/she will be responsible for: EBBE (1 of 7) EBBE RESPIRATORY PROTECTION POLICY The Muskogee School District is acknowledged as the employer, and as outlined under current Federal regulations, is assigned the responsibility to provide

More information

Class 1 Cartridges and Filters for use with Honeywell Twin Filter half and full-face masks We listened to you. Respiratory Protection

Class 1 Cartridges and Filters for use with Honeywell Twin Filter half and full-face masks We listened to you. Respiratory Protection Respiratory Protection COMFORT, PROTECTION, FLEXIBILITY Class 1 Cartridges and Filters for use with Honeywell Twin Filter half and full-face masks We listened to you Class 1 Cartridges and Filters - for

More information

RESPIRATORY PROTECTION PROGRAM OSHA Respiratory Protection

RESPIRATORY PROTECTION PROGRAM OSHA Respiratory Protection RESPIRATORY PROTECTION PROGRAM 1910.134 OSHA Respiratory Protection Table of Contents Introduction... 3 Scope... 3 Definitions... 3 Responsibilities... 5 Voluntary Use... 6 Use Requirements... 6 Program

More information

Technical. Datasheet 3M Reusable Half Face Respirator 6000 Series. Main Features. Applications

Technical. Datasheet 3M Reusable Half Face Respirator 6000 Series. Main Features. Applications Technical Datasheet 3M Reusable Half Face Respirator 6000 Series Main Features The 3M 6000 Series Respirators are proven to be simple to handle and comfortable to the wearer. The exhalation port provides

More information

University of Dayton Respiratory Protection Program 29 CFR

University of Dayton Respiratory Protection Program 29 CFR University of Dayton Respiratory Protection Program 29 CFR 1910.134 What to expect from this training: Employees who are required to use respirators must be trained such that they can demonstrate knowledge

More information

North RU8500 Series Half Masks

North RU8500 Series Half Masks North RU8500 Series Half Masks The RU8500 Series is a silicone half mask compatible with the North N-Series cartridges and filters. The half mask has a speech diaphragm for improved voice clarity and is

More information

Differentiation in a me-too marketplace.

Differentiation in a me-too marketplace. Head Harness for secure positioning. Adjustable strap for custom fit. Differentiation in a me-too marketplace. Flexwing design for comfortable one strap fit. Moldex respiratory and hearing protection products

More information

Section 3. Respiratory Protection Plan (SPPM 3.24)

Section 3. Respiratory Protection Plan (SPPM 3.24) Section 3. Respiratory Protection Plan (SPPM 3.24) Contents 3.1 Respiratory Protection Plan Objective... 3-1 3.2 Respiratory Hazard Assessment... 3-2 3.3 Medical Evaluation... 3-2 3.4 Respirator Selection...

More information

EP30g, Respiratory Protection.pdf

EP30g, Respiratory Protection.pdf Respiratory Protection University of California Irvine Medical Center Environmental Health and Safety Procedures Section: Safety Reviewed/Revised: 05/10 1. Introduction Good health depends on breathing

More information

Respirator with Ultra-Twin, Ultravue, Ultra Elite, or Duo-Twin TM Facepiece

Respirator with Ultra-Twin, Ultravue, Ultra Elite, or Duo-Twin TM Facepiece Respirator with Ultra-Twin, Ultravue, Ultra Elite, or Duo-Twin TM Facepiece instructions for use and care This manual, including the warnings and cautions inside, must be read and followed carefully by

More information

ALBUQUERQUE PUBLIC SCHOOLS RESPIRATORY PROTECTION PROGRAM

ALBUQUERQUE PUBLIC SCHOOLS RESPIRATORY PROTECTION PROGRAM ALBUQUERQUE PUBLIC SCHOOLS RESPIRATORY PROTECTION PROGRAM Risk Management Department August, 2008 ALBUQUERQUE PUBLIC SCHOOLS RISK MANAGEMENT DEPARTMENT RESPIRATORY PROTECTION PROGRAM TABLE OF CONTENTS

More information

"RESPIRATORY PROTECTION AND SAFETY"

RESPIRATORY PROTECTION AND SAFETY PRESENTER'S GUIDE "RESPIRATORY PROTECTION AND SAFETY" Training for the OSHA RESPIRATORY PROTECTION STANDARD Quality Safety and Health Products, for Today...and Tomorrow OUTLINE OF MAJOR PROGRAM POINTS

More information

USE INSTRUCTIONS SCOTT HEALTH AND SAFETY PROMASK 25 FULL FACEPIECE RESPIRATOR USE INSTRUCTIONS

USE INSTRUCTIONS SCOTT HEALTH AND SAFETY PROMASK 25 FULL FACEPIECE RESPIRATOR USE INSTRUCTIONS USE INSTRUCTIONS SCOTT HEALTH AND SAFETY PROMASK 25 FULL FACEPIECE RESPIRATOR USE INSTRUCTIONS TABLE OF CONTENTS DESCRIPTION... 1 GENERAL LIMITATIONS ON USE... 2 FACEPIECE FITTING... 5 USE OF THE RESPIRATOR...

More information

DREW UNIVERSITY RESPIRATORY PROTECTION PROGRAM DRAFT 06/11

DREW UNIVERSITY RESPIRATORY PROTECTION PROGRAM DRAFT 06/11 PURPOSE This policy provides requirements on the selection, use, care, and maintenance of respiratory protection. Also included is information and guidelines on training, medical evaluations, recordkeeping

More information

Texas Department of Insurance. Respiratory Protection. Provided by. Workers Health & Safety HS01-027B (1-06)

Texas Department of Insurance. Respiratory Protection. Provided by. Workers Health & Safety HS01-027B (1-06) Texas Department of Insurance Respiratory Protection Provided by Workers Health & Safety HS01-027B (1-06) Contents Introduction... 3 Definitions... 3 Approved Respirators... 3-4 New Respirator Selection

More information

3M Personal Safety Division 3M HALF FACEPIECE REUSABLE RESPIRATORS

3M Personal Safety Division 3M HALF FACEPIECE REUSABLE RESPIRATORS 3M Personal Safety Division 3M HALF FACEPIECE REUSABLE RESPIRATORS The 3M family of respirators offers a variety of options to help you make the best choice. No matter what the job calls for or what your

More information

Datasheet. Technical. 3M 6000 Series Full Face Masks. Main Features

Datasheet. Technical. 3M 6000 Series Full Face Masks. Main Features Technical Datasheet 3M 6000 Series Full Face Masks Main Features The 3M 6000 Series Full Face Masks are proven to be simple to handle and comfortable to the wearer. The new exhalation port provides increased

More information

Standards of Practice Respiratory Protection: Appendix C

Standards of Practice Respiratory Protection: Appendix C Document Authority: EHS Coordinator Standards of Practice Respiratory Protection: Appendix C Document Custodian: EH&S Coordinator Effective Date: 09.01.15 Issuing Dept: College of Agriculture EH&S Next

More information

Datasheet. Technical. 3M 6000 Series Reusable Half Masks. Main Features. Applications

Datasheet. Technical. 3M 6000 Series Reusable Half Masks. Main Features. Applications Technical Datasheet 3M 6000 Series Reusable Half Masks Main Features The 3M 6000 Series Reusable Half Masks are proven to be simple to handle and comfortable to the wearer. The new exhalation port provides

More information

Barry Sanders has the following disclosures to make:

Barry Sanders has the following disclosures to make: Overview to Mask Fit Testing Barry Sanders June 20, 2018 Mask Fit Testing June 20, 2018 San Antonio, TX EXCELLENCE EXPERTISE INNOVATION Barry Sanders has the following disclosures to make: He is an employee

More information

Respiratory Protection Basics

Respiratory Protection Basics Michigan Safety Conference Respiratory Protection Basics Date: April 17, 2018 0 16 April 3M 2018. All Rights Reserved. Presenter Don Rust, CIH, CSP Technical Service Specialist 3M Personal Safety Division

More information

Checklist for care of Respirators

Checklist for care of Respirators Checklist for care of Respirators Inspect the respirator before and after each use and during cleaning. Inspect equipment designated for "emergency use" at least monthly, and after each use. Replace all

More information

Respiratory Protection Program

Respiratory Protection Program Policy 707 Respiratory Protection Program 707.1 PURPOSE AND SCOPE The is committed to preventing injury and illness in the workplace and makes every effort to protect our employees from harmful airborne

More information

Respiratory Protection in Agriculture

Respiratory Protection in Agriculture Respiratory Protection in Agriculture Glen H. Hetzel, Extension Agricultural Engineer Virginia Tech Introduction Who Needs Respiratory Protection? THOSE working in dusty fields and buildings THOSE handling

More information

HAZWOPER 8-Hr Refresher Aug. 20, 2012

HAZWOPER 8-Hr Refresher Aug. 20, 2012 Institute for Tribal Environmental Professionals Tribal Lands and Environment: A National Forum on Solid Waste, Emergency Response, Contaminated Sites and USTs August 20-23, 2012 Coos Bay, Oregon HAZWOPER

More information

Respirator with Ultra-Twin, Ultravue, Ultra Elite, or Duo-Twin TM Facepiece

Respirator with Ultra-Twin, Ultravue, Ultra Elite, or Duo-Twin TM Facepiece Respirator with Ultra-Twin, Ultravue, Ultra Elite, or Duo-Twin TM Facepiece instructions for use and care This manual, including the warnings and cautions inside, must be read and followed carefully by

More information

BGC HOLDINGS LTD RESPIRATORY PROTECTIVE EQUIPMENT (RPE) POLICY

BGC HOLDINGS LTD RESPIRATORY PROTECTIVE EQUIPMENT (RPE) POLICY BGC HOLDINGS LTD RESPIRATORY PROTECTIVE EQUIPMENT (RPE) POLICY Introduction This document sets out the Health & Safety arrangements we have established for BGC Holdings Ltd, and all subsidiary and associated

More information

Combination Breathing Apparatus

Combination Breathing Apparatus and Combination Breathing Apparatus ULTRAVUE FACEPIECE TAL 502 (L) Rev. 0 MSA 2005 Prnt. Spec. 10000005389 (I) Mat. 10064385 Doc. 10064385 ULTRAVUE FACEPIECE COMPONENTS Item Part No. Description 800509

More information

Technical. Datasheet 3M Reusable Half Face Respirator 7500 Series. Main Features. Applications

Technical. Datasheet 3M Reusable Half Face Respirator 7500 Series. Main Features. Applications Technical Datasheet 3M Reusable Half Face Respirator 7500 Series Main Features 3M 7500 Series Respirators have set a new standard in comfort. The exhalation valve provides increased durability and is easy

More information

X. PERSONAL PROTECTIVE EQUIPMENT

X. PERSONAL PROTECTIVE EQUIPMENT X. PERSONAL PROTECTIVE EQUIPMENT 1.0 Personal Protective Equipment Defined 1.1 Personal Protective Equipment (PPE) includes all clothing and work accessories designed to protect employees from workplace

More information

RESPIRATORS & FIT TESTING

RESPIRATORS & FIT TESTING RESPIRATORS & FIT TESTING Presented By: Jamie Papian Licensed Lead & Asbestos Inspector Licensed Lead & Asbestos Abatement Supervisor HUD Housing Quality Standards Inspector State of Iowa, Illinois and

More information

Hoods BE-10 Series User Instructions for 3M TM Hoods BE-10, BE-10L and BE-10BR

Hoods BE-10 Series User Instructions for 3M TM Hoods BE-10, BE-10L and BE-10BR Hoods BE-10 Series User Instructions for 3M TM Hoods BE-10, BE-10L and BE-10BR (Keep these User Instructions for reference) This product helps protect against certain airborne contaminants. Misuse may

More information

RESPIRATORY PROTECTION

RESPIRATORY PROTECTION RESPIRATORY PROTECTION OSHA 29 CFR 1910.134 PPT-042-01 1 Respiratory Protection Respirators shall be provided when necessary to protect the health of employees from breathable hazards (should be used as

More information

RESPIRATORY PROTECTIVE EQUIPMENT ADVICE FOR WORKERS

RESPIRATORY PROTECTIVE EQUIPMENT ADVICE FOR WORKERS H E A LT H & S A F E T Y AT WO R K HSWA AC T FACT SHEET RESPIRATORY PROTECTIVE EQUIPMENT ADVICE FOR WORKERS Respiratory protective equipment (RPE) is a type of personal protective equipment (PPE) that

More information

Identify, evaluate and assess workplace improvements to reduce hazards. Provide personal protective equipment based on hazard assessment

Identify, evaluate and assess workplace improvements to reduce hazards. Provide personal protective equipment based on hazard assessment PAGE 1 OF 7 1.0 INTRODUCTION The purpose of this program is to help employees work safely in their environments by identifying and assessing workplace hazards, eliminating or reducing the hazards where

More information

Don t Forget About Fit What You Need to Know About Respirator Fit-testing

Don t Forget About Fit What You Need to Know About Respirator Fit-testing Session No. 667 Don t Forget About Fit What You Need to Know About Respirator Fit-testing Scott Larson, BS, MS, CSP, CIH 3M Personal Safety Division St. Paul, MN Megan Torgrude, BS, MPH, CIH 3M Personal

More information

Comfort. Versatility. Simplicity. 3M Versaflo M-Series Faceshields, Hard Hats, and Helmets

Comfort. Versatility. Simplicity. 3M Versaflo M-Series Faceshields, Hard Hats, and Helmets 3M Versaflo TR-300-HIK Heavy Industry PAPR Kit 1/Case 3M Versaflo M-Series Faceshields, Hard Hats, and Helmets Comfort Simplicity Versatility 3M Versaflo M-Series Headgear for Powered and Supplied Air

More information

Fire Escape Hood OPERATION AND INSTRUCTIONS

Fire Escape Hood OPERATION AND INSTRUCTIONS TM Fire Escape Hood OPERATION AND INSTRUCTIONS THIS MANUAL MUST BE CAREFULLY READ AND FOLLOWED BY ALL PERSONS WHO HAVE, OR WILL HAVE, THE RESPONSIBILITY FOR USING THE S-CAP FIRE ESCAPE HOOD. THESE ESCAPE

More information

San Mateo County Health System Environmental Health Services Division. Respirator Use

San Mateo County Health System Environmental Health Services Division. Respirator Use 1.0 PURPOSE This document describes the requirements for the use of respiratory protection and constitutes a written Respiratory Protection Program. Its purpose is to ensure that employees adhere to the

More information

Safety Wear. Peace of Mind

Safety Wear. Peace of Mind Peace of Mind - 331 - T25200 Safety Goggles Protects against flying particles from grinding, chipping and cutting operations Lightweight, soft frame mold High-impact, clear, polycarbonate lens Vertical

More information

Vortex Tube Respirator

Vortex Tube Respirator Vortex Tube Respirator INSTRUCTIONS This manual, including the warnings and cautions inside, must be carefully read and followed by all persons who use or maintain this product, including those who have

More information

West Clinton Fire District

West Clinton Fire District 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 West Clinton Fire District Best Practice Respiratory Protection Program Best

More information

RESPIRATORY PROTECTIVE EQUIPMENT ADVICE FOR PERSONS CONDUCTING A BUSINESS OR UNDERTAKING

RESPIRATORY PROTECTIVE EQUIPMENT ADVICE FOR PERSONS CONDUCTING A BUSINESS OR UNDERTAKING H E A LT H & S A F E T Y AT WO R K HSWA AC T FACT SHEET RESPIRATORY PROTECTIVE EQUIPMENT ADVICE FOR PERSONS CONDUCTING A BUSINESS OR UNDERTAKING This fact sheet is for persons conducting a business or

More information

City of Kalispell RESPIRATOR PROTECTION POLICY October 12, 2015

City of Kalispell RESPIRATOR PROTECTION POLICY October 12, 2015 A. Executive Summary and Introduction City of Kalispell RESPIRATOR PROTECTION POLICY October 12, 2015 1. Annual fit test is required for all employees who will be required to wear a respirator as a part

More information

Northern Kentucky University Issue Date: 11/02/2018 Revised Date: Title: PERSONAL PROTECTIVE EQUIPMENT PROCEDURE OBJECTIVE AND PURPOSE

Northern Kentucky University Issue Date: 11/02/2018 Revised Date: Title: PERSONAL PROTECTIVE EQUIPMENT PROCEDURE OBJECTIVE AND PURPOSE Northern Kentucky University Issue Date: 11/02/2018 Revised Date: Policy Link: Occupational Safety Policy Title: PERSONAL PROTECTIVE EQUIPMENT PROCEDURE OBJECTIVE AND PURPOSE The objective of this procedure

More information

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION DUAL SUPPLY REGULATOR ESCAPE CYLINDER VORTEX MAIN INLET PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION WARNING THIS MANUAL MUST BE READ CAREFULLY BY ALL PERSONS WHO HAVE OR WILL HAVE THE RESPONSIBILITY

More information

COLUMBUS STATE COMMUNITY COLLEGE EMPLOYEE SAFETY MANUAL

COLUMBUS STATE COMMUNITY COLLEGE EMPLOYEE SAFETY MANUAL COLUMBUS STATE COMMUNITY COLLEGE EMPLOYEE SAFETY MANUAL (Hand, Eye, Face, Head, Foot, and Respiratory) Effective October 15, 1995 Page 1 of 15 Updated September 2010 A. At the request of the College Safety

More information

How to Comply With the 2015 Revised Worker Protection Standard For Agricultural Pesticides. What Owners and Employers Need To Know

How to Comply With the 2015 Revised Worker Protection Standard For Agricultural Pesticides. What Owners and Employers Need To Know How to Comply With the 2015 Revised Worker Protection Standard For Agricultural Pesticides What Owners and Employers Need To Know ADDITIONAL HANDLER EMPLOYER REQUIREMENTS Medical evaluation 40 CFR 170.507(b)(10)(iii)

More information

The Following information is based on material prepared by the American Lung Association

The Following information is based on material prepared by the American Lung Association The Following information is based on material prepared by the American Lung Association RESPIRATORY PROTECTION FROM INHALATION HAZARDS The inhalation of harmful dusts, toxic gases and vapors at fire and

More information