Stock Lifters IDEAL FOR IMPROVED PART HANDLING THROUGH GUIDED LIFTING SYSTEMS

Size: px
Start display at page:

Download "Stock Lifters IDEAL FOR IMPROVED PART HANDLING THROUGH GUIDED LIFTING SYSTEMS"

Transcription

1 tock Lifters IDEAL FOR IMPROVED PART HANDLING THROUGH GUIDED LIFTING YTEM

2 Introduction tock Lifters 2

3 tock Lifters Introduction IDEAL FOR IMPROVED PART HANDLING THROUGH GUIDED LIFTING YTEM Table of Contents...Page INGLE POT ERIE TOCK LIFTER PED Certification... 2 Product Value & Features... 2 Advanced afety Features... 2 Product pecifications & Capacities... 3 Ordering Instructions & Repair/Replacement prings... 3 Force Charts... 3 Mounting Options... 3 T2LT T2LE T2LM RL RAIL LIFTER PED Certification... 6 Product Value & Features... 6 Advanced afety Features... 6 Product pecifications & Capacities... 7 Ordering Instructions & Repair Kits... 7 Mounting Options... 7 T2RL Function Example... 9 DUAL POT ERIE TOCK LIFTER PED Certification Product Value & Features Advanced afety Features Product pecifications & Capacities Ordering Instructions & Repair/Replacement prings Application Examples T2DPL T2DPL General Information Hyson, headquartered in Brecksville, Ohio, is a world class engineering and manufacturing company that provides high-quality, safetyengineered force control solutions for a wide range of applications and industries, including automotive, aerospace, appliance, medical and HVAC. Hyson partners with our customers to understand applications and provide the best solutions for each one. We are a full service force control provider for critical machine, vehicle and precision metal processing applications, meaning we can supply dependent upon each customer s needs, including: gas springs, cam systems, cushions, manifolds and knockout systems. Our success lies with our commitment to continually improve ourselves, our processes and our products to ensure we meet or exceed our customers expectations. Our IO-9001, A-9000 and PED certifications attest to our ongoing commitment to the highest standards of quality. 1

4 Overview ingle Post tock Lifters T2LE and T2LT T2LT T2LE T2LM PED Pressure Equipment Directive Hyson gas springs are designed to meet customer expectations for reliability, safety and service lifetime. The design, manufacture and testing of Hyson gas springs has been approved according to the European Pressure Equipment Directive (97/23/EC). The Pressure Equipment Directive (PED) replaces all previous European legislation governing the design, manufacture and testing of pressure vessels. Product Value Versatile and compact, Hyson s T2LE and T2LT ingle Post tock Lifters provide many guide rail mounting options for stock lifting. They can be used for single-point lifting of short rails, or multi-point lifting of long rails. Our ingle Post tock Lifters are designed to account for rail misalignment and prevent rails from sticking. Additionally, the T2LE and T2LT Lifters can be linked together to optimize force distribution. Product Features Easily adjustable force Eliminates the need for additional guide bushings and anti-rotational features T2LE and T2LT can be hosed together for uniform force Advanced afety Features Over-Pressure : designed to safely vent excessive gas pressure in the event of an over-pressure situation such as overcharged gas springs or the ingestion of large amounts of drawing or cooling fluids. Overload Overpressure Overstroke Over- : A patented system allows the venting of gas in a pre-determined manner with deformation or knock-out plug in the event of a mechanical overload of the gas spring body. Overload : In the case of blockage in the tool that causes excessive piston return speed, a specially-designed rod and integral safety stops retain the piston rod in the gas spring and allow gas to vent safely. 2

5 ingle Post tock Lifters Overview T2LT-170 & T2LME-170 Product pecifications T2LM-300 Initial Force Range ,700 N Pressure Medium...Nitrogen Gas Max. Charging Pressure bar/2610 psi Min. Charging Pressure...25 bar/360 psi Operating Temperature...0 to 80 C/32 to 176 F Force Increase by Temperature...±0.3% / C Recommended Max. s per Minute (at 20 C) Maximum Piston Rod Velocity: m/s Maximum Utilized...100% Initial Force Range ,200 N Pressure Medium...Nitrogen Gas Max. Charging Pressure bar/2610 psi Min. Charging Pressure...25 bar/360 psi Operating Temperature...0 to 80 C/32 to 176 F Force Increase by Temperature...±0.3% / C Recommended Max. s per Minute (at 20 C) Maximum Piston Rod Velocity: m/s Maximum Utilized...100% T2L-170 Force Chart (Lbs. force at 180 bar/2610 psi) mm mm mm mm mm mm N N N N N N 25 2, ,308 2, ,129 2,441 2, ,953 2,108 2,275 2, ,899 2,014 2,134 2,508 2, ,858 1,945 2,033 2,294 2,508 2,839 T2-LM-300 Force Chart (Lbs. force at 180 bar/2610 psi) mm mm mm mm mm mm mm mm mm mm N N N N N N N N N N 25 4, ,655 4, ,465 3,800 4, ,405 3,660 4,025 4, ,355 3,555 3,825 4,025 4, ,330 3,485 3,700 3,855 4,070 4, ,315 3,465 3,655 3,790 3,985 4,195 4, ,305 3,440 3,615 3,745 3,915 4,105 4,210 4, ,290 3,405 3,555 3,665 3,805 3,960 4,050 4,130 4, ,285 3,395 3,540 3,635 3,775 3,815 3,995 4,070 4,245 4,315 Mounting Options T2LT-170 & T2LE Ordering Instructions T2LX-XXX X XXXX Mounting Options T2LM-300 Model length Guide rail T2LT-170 T2LE-170 T2LM-300 ee Dimensional Information Charts All gas springs shipped at maximum charge pressure unless otherwise specified. tock Lifter Note! Use LM CAP for multi-point lifting only. Die plate Guide rail Note! Use threaded holes for single point lifting. tock Lifter Die plate Two T2LM 300 stock lifters with equal used stroke ratings can be applied. 3

6 T2LT & T2LE-170 ingle Post tock Lifters Advanced afety Features Ø Ø Overload Y 17 Y L 17 Overpressure L Overstroke Attachment Capacity Maximum Attachment Capacity per Lifter**Metric Ram Velocity (m/s) Attachment Mass (kg) T2LT-170 T2LE Ø 6-0 (2x) Dowels ** Determine ram velocity and reference the recommended attachment mass per lifter. For increased capacity, install external positive stops to prevent lifter damage. 30 M8 (4x) socket head screw Ø ± M10 Depth 15 Ø 4 Depth 5 Access to M6 Charge Port Ø 6-0 (2x) Dowels 30 Ø ± M8 (4x) socket head screw Access to M6 Charge Port 9.9 Repair/Replacement prings Lifter eries T2LT-170 T2LE-170 Order Number 22 T3-170X(TROKE) 50 T2LT-170 Dimensional Information Order Number Model x T2LT-170x25 25 Initial Contact* Force +20 C End Force* at Full Y ± 0.25 L Gas Weight Volume (l) mm N lbf N lbf mm mm kg T2LT-170x T2LT-170x T2LT-170x , , T2LT-170x T2LT-170x T2LT-170x * At full charge T2LE-170 Dimensional Information Order Number Model x T2LE-170x25 25 Initial End Force* Y Contact* at L Gas Weight ± 0.25 Force +20 C Full Volume (l) mm N lbf N lbf mm mm kg T2LE-170x T2LE-170x T2LE-170x , , T2LE-170x T2LE-170x T2LE-170x

7 ingle Post tock Lifters T2LM-300 Advanced afety Features Ø 44.4 Overload 6.6 For Ø 8 mm slotted pin G 1/8 charge port 2x R ±0.05 2x45 12± Overpressure Y L Ø 8 Ø 18 Ø Overstroke Order No. LM CAP (old separately) LM CAP option to be mounted at top of T2LM-300 and linked to guide rails of the die with a slotted pin. Ø Ø 10-0 (2x) Dowels Repair Kit Lifter eries Order Number T2LM-300 T2LMK Ø 18 Depth 14.5 Ø 30 M10 socket head screw M8 (2x) Depth 19 T2LM-300 Dimensional Information End Force* Order Number Initial Contact * at Gas Model x Force + 20 C Full Y L volume Weight mm N lbf N lbf ±0.25 (l) (kg) T2LM 300x , T2LM 300x , T2LM 300x , T2LM 300x , T2LM 300x , , T2LM 300x , T2LM 300x , T2LM 300x , T2LM 300x , T2LM 300x , *At full stroke Max. attachment capacity per lifter* Metric Ram velocity (m/s) Attachment mass (kg) *Attachment mass assumes balanced load and actuation force. For increased capacity, install external positive stops to prevent lifter damage. 5

8 Overview RL Rail Lifters T2RL-800 PED Pressure Equipment Directive Hyson gas springs are designed to meet customer expectations for reliability, safety and service lifetime. The design, manufacture and testing of Hyson gas springs has been approved according to the European Pressure Equipment Directive (97/23/EC). The Pressure Equipment Directive (PED) replaces all previous European legislation governing the design, manufacture and testing of pressure vessels. Product Values Ideal for lifting stock in multi-point guide rails, Hyson s T2RL RaiL Lifter has a compact design with the added benefit of return speed control, significantly reduces strip feed bounce and shock loading. The last 20 mm of return stroke is dampened to 0.2m/s, stabilizing the part during production and leading to longer lifter life in extreme applications. RL Rail Lifters can also be linked togother to optimize force distribution. Product Features implifies tool design, saving cost and space Eliminates the need for additional guide bushings Easily adjustable force (linkable using a hose system) Linkable using hose system for uniform lifting force Additional mounting options using NP-1500 flanges Advanced afety Features Over-Pressure : designed to safely vent excessive gas pressure in the event of an over-pressure situation such as overcharged gas springs or the ingestion of large amounts of drawing or cooling fluids. Overload Overpressure Overstroke Over- : A patented system allows the venting of gas in a pre-determined manner with deformation or knock-out plug in the event of a mechanical overload of the gas spring body. Overload : In the case of blockage in the tool that causes excessive piston return speed, a specially-designed rod and integral safety stops retain the piston rod in the gas spring and allow gas to vent safely. 6

9 RL Rail Lifters Overview Product pecifications Pressure Medium... Nitrogen Gas Max. Charging Pressure...70 bar/1015 psi Min. Charging Pressure bar/218 psi Operating Temperature...0 to 80 C/32 to 176 F Force Increase by Temperature...±0.3% per C/±0.009% per F Recommended Max. s per Minute (at 20 C/68 F) Dampening Length mm Dampening Velocity m/s NOTE: By halving the initial charge pressure, the number of spm can be doubled. Attachment Capacity Maximum Attachment Capacity per Lifter** Ram Velocity Attachment Mass (kg) (m/s) T2RL ** Determine ram velocity and reference the recommended attachment mass per lifter. For increased capacity, install external positive stops to prevent lifter damage. Ordering Instructions T2RL-800 X XXXX l l Model Length l ee Dimensional Information Charts All gas springs shipped at maximum charge pressure unless otherwise specified. Repair Kit Lifter eries Order Number T2RL Mounting Options Mounting crew Locating Dowel 7

10 T2RL-800 Rail Lifters Advanced afety Features M16 Ø36 Overload Overpressure L Y Overstroke Ø 75.2 M8 X 1.25 depth 13 on Ø 40 B.C. G 1/8 Charge Port Ø Ø 11 (4x) Ø 10 T2RL-800 Dimensional Information Order Number Model x T2RL-800x50 50 Initial Contact* Force +20 C End Force* at Full Y ± L Gas Volume (l) Weight mm N lbf N lbf mm mm kg 8,800 1, T2RL-800x ,200 2, T2RL-800x ,400 2, T2RL-800x ,100 1,596 9,600 2, T2RL-800x ,700 2, T2RL-800x ,800 2, T2RL-800x ,900 2, * At full charge

11 Rail Lifters T2RL-800 Function Example 2 NOTE: T2RL prings provide a 90% reduction of blank holder force. 9

12 Overview Dual Post tock Lifters DUAL POT T2DPL ERIE TOCK LIFTER T2DPL-90 T2DPL-200 PED Pressure Equipment Directive Hyson gas springs are designed to meet customer expectations for reliability, safety and service lifetime. The design, manufacture and testing of Hyson gas springs has been approved according to the European Pressure Equipment Directive (97/23/EC). The Pressure Equipment Directive (PED) replaces all previous European legislation governing the design, manufacture and testing of pressure vessels. Product Value With a built-in rail plate, Dual Post guidance, and upstroke dampening, Hyson s Dual Post tock Lifter gives you the most robust guidance for both single-point and multi-point rail lifting, allowing you to precisely locate your guide rail. Product Features tandard dowel pin holes for accurate position Upstroke dampening feature reduces strip feed bounce Drop-in mount on gas spring for easy replacement Drain holes on lower plate eliminate fluid build-up above the gas spring Linkable using hose system for uniform lifting force Advanced afety Features Over-Pressure : designed to safely vent excessive gas pressure in the event of an over-pressure situation such as overcharged gas springs or the ingestion of large amounts of drawing or cooling fluids. Overload Overpressure Overstroke Over- : A patented system allows the venting of gas in a pre-determined manner with deformation or knock-out plug in the event of a mechanical overload of the gas spring body. Overload : In the case of blockage in the tool that causes excessive piston return speed, a specially-designed rod and integral safety stops retain the piston rod in the gas spring and allow gas to vent safely. 10

13 Dual Post tock Lifters Overview Product pecifications Initial Force Range - T2DPL N Initial Force Range - T2DPL ,000 N Pressure Medium... Nitrogen Gas Max. Charging Pressure bar/2,610 psi Min. Charging Pressure bar/360 psi Operating Temperature... 0 to 80 C/32 to 176 F Force Increase by Temperature... ±0.3% per C Max. s/minute T2DPL (at 20 C) Max. s/minute T2DPL (at 20 C) Max. Velocity... ee table Max. Utilized... 95% Attachment Capacity Maximum Attachment Capacity per Lifter** Ram Velocity Attachment Mass (kg) (m/s) T2DPL-90 T2DPL ** Determine ram velocity and reference the recommended attachment mass per lifter. For increased capacity, install external positive stops to prevent lifter damage. Ordering Instructions T2DPL-XXXX X l Model l T2DPL-90 T2DPL-200 XXXX l Length l ee Dimensional Information Charts All gas springs shipped at maximum charge pressure unless otherwise specified. Repair/Replacement prings Post eries T2DPL-90 T2DPL-200 Order Number* T2-90x(TROKE) T2-180x(TROKE) Application Examples Fig. 1 Rail plate used as direct lift Fig. 2 Rail plate with guide rail attached Fig. 3 Custom designed guide rails may be attached to the T2DPL-90 or T2DPL-200 rail plate, shown in Fig. 3. This arrangement allows for continuous material feed during the course of operation. When using multiple lifters, use dowel pin holes on one lifter only to prevent binding. 11

14 Dual Post tock Lifters T2DPL-90 Advanced afety Features T2DPL 90x025 T2DPL 90x38 to T2DPL 90x Overload Dowel pin holes Ø 8, depth 12 mm (2x) 115 M10 (2x) Overpressure 50 ± ± ± Ø 16 A 26 Ø A Ø 11 B Ø 22 B Ø 16 Ø 11 M10 (2x) Ø 22 Ø 19 M10 (2x) 15 M10 (2x) Ø Overstroke Dowel pin holes (2x) Ø M10 (2x) 85 Dowel pin holes Ø 8, depth 12 mm Dowel pin holes Ø 8, depth 12 mm (2x) Ø 16 (2x) Ø 17 A 12 B 20+ Dowel pin Ø 11 holes (2x) Ø 22 Ø8 M10 (2x) Dowel pin holes (2x) Ø8 Ø 19 Ø T2DPL-90 Dimensional Information Order Number Model x T2DPL-90x25 23 mm Initial Contact* Force +20 C N lbf End Force* at Full A B Weight N lbf mm mm kg 1, T2DPL-90x , T2DPL-90x , T2DPL-90x , T2DPL-90x , T2DPL-90x , T2DPL-90x , T2DPL-90x150 * At full charge 148 1,

15 Dual Post tock Lifters T2DPL-200 Advanced afety Features T2DPL 200x025 T2DPL 200x038 to T2DPL 90x200 Overload Overpressure ± ± Overstroke 31.8 Dowel pin holes (2x) Ø Dowel pin holes 15 Ø 10, depth 12 mm (2x) Ø 20 Ø M12 2 (2x) A 26 Ø 20 M12 2 (2x) Ø Dowel pin holes Ø 10, depth 12 mm (2x) B Ø 13 A B 22+ M12 2 (2x) Ø Ø 13 Dowel pin holes (2x) ØØ Ø 26 M12 (2x) M8 (4x) Ø 20 Ø 13 Ø M12 (2x) M8 (4x) A ± Dowel pin holes 100 Ø 10, depth 12 mm (2x) 64 M8 (4x) 50 B Dowel pin holes (2x) Ø 10 Ø 25 Ø 25 Ø T2DPL-200 Dimensional Information Order Number Model x T2DPL-200x25 23 mm Initial Contact* Force +20 C N lbf End Force* at Full A B Weight N lbf mm mm kg 3, T2DPL-200x , T2DPL-200x , T2DPL-200x , T2DPL-200x , T2DPL-200x , T2DPL-200x , T2DPL-200x , T2DPL-200x , T2DPL-200x , , * At full charge 13 22

16 METAL FORMING OLUTION TM U..A. Headquarters Brecksville Road Brecksville, OH UA Tel: , Hyson 2016 tocklifters 2M 06/16

Stock Lifters SLME 170 SLMT 170 SLM 300 SPC 800

Stock Lifters SLME 170 SLMT 170 SLM 300 SPC 800 Product eries ifters tock ifters ME 170 MT 170 M 300 PC 800 Would you like to order this product? All available information at kaller.com FEATURE AND BENEFIT tock ifters KAER tock ifters ME 170, MT 170

More information

TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS

TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS O-Ring Face Seal Hose TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS O-Ring Face Seal METAL FORMING SOLUTIONS THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS Table of

More information

DI-DRO ADVANCED FORMING SYSTEMS

DI-DRO ADVANCED FORMING SYSTEMS DI-DRO ADVANCED FORMING SYSTEMS WE PARTNER WITH YOU We partner with you to provide force-generating products and solutions to lower your costs and increase your productivity in the forming of manufactured

More information

DI-DRO ADVANCED FORMING SYSTEMS

DI-DRO ADVANCED FORMING SYSTEMS DI-DRO ADVANCED FORMING SYSTEMS WE PARTNER WITH YOU We partner with you to provide force-generating products and solutions to lower your costs and increase your productivity in the forming of manufactured

More information

New Models! UX.1600 UX.20000

New Models! UX.1600 UX.20000 atalog No. 07105 Ultra Force Extended UX eries New Models! UX.1600 UX.000 Patent pending Reduce die construction costs ong stroke lengths Directly upgrade IO 750-10000 models Variety of attachable and

More information

Gripping rotary modules

Gripping rotary modules Gripping rotary modules Gripping rotary modules GRIPPING ROTARY MODULES Series Size Page Gripping rotary modules RP 314 RP 1212 318 RP 1216 322 RP 1520 326 RP 2120 330 RP 2128 334 RC 338 RC 1212 342 RC

More information

Nitrogen Gas Spring Hose System Components

Nitrogen Gas Spring Hose System Components Nitrogen Gas Spring Hose System Components Control Panels TNKMAN Distribution Blocks Compression Tanks Hose Systems with Hoses, Fittings and Adapters Micro EO24 Hose and Tube System EZ-Hose System EO24-Hose

More information

Dyne-A-Cam Series NITRO-CAM MANUAL

Dyne-A-Cam Series NITRO-CAM MANUAL NIRO-CM MNUL BSIC PRINCIPLES, DYNMIC SOLUIONS SM NCM0100100 NIRO-CM MNUL able of Contents Page General Description... 2 Features and Benefits... 3 How the System Works... 4 Component Selection... 5-11

More information

Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS

Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS HOSE REELS SIGNATURE SERIES H O S E S R E E L S FEATURES & BENEFITS Eight position locking precision die cast latch mechanism, with secure

More information

Bores: ø 10, 16, 20, 25, 32 mm

Bores: ø 10, 16, 20, 25, 32 mm > Series CGLN wide opening parallel grippers CATALOGUE > Release 8.8 Series CGLN wide opening parallel grippers New version Bores: ø 0, 6, 20, 25, 32 mm»» High installation versatility»» Rack and pinion

More information

4400 TwinHybrid Gas Seal

4400 TwinHybrid Gas Seal 4400 TwinHybrid Gas Seal EQUIPMENT PREPARATION MECHANICAL SEAL INSTALLATION INSTRUCTIONS 1 2 200.005" 0,13 mm 125 µ" 3,2 µm R a 3 4 32 µ" 0,8 µm R a 1000 ±.002" 0,05mm CAUTIONS These instructions are general

More information

2-JAW SELF-CENTERING PARALLEL PNEUMATIC GRIPPER (SERIES HS)

2-JAW SELF-CENTERING PARALLEL PNEUMATIC GRIPPER (SERIES HS) HS 2-JAW SELF-CENTERING PARALLEL PNEUMATIC GRIPPER (SERIES HS) Designed for high-speed machines. Very short closing/opening times. Lightweight. Maintenance-free long life and reliability. Long stroke.

More information

Leak-Free Load-Control Valve SAE ½ psi flange

Leak-Free Load-Control Valve SAE ½ psi flange Leak-Free Load-Control Valve SE ½ - 6000 psi flange Q max = 150 l/min [40 gpm], p max = 420 bar [6000 psi] leak-proof, two-stage hydraulic, SE-flange design 12--S... 1 Description Two-stage load-control

More information

Index Table. Model 794. Installation, Operating and Maintenance Instructions

Index Table. Model 794. Installation, Operating and Maintenance Instructions CLOCKWISE MANUAL MAKING INTO CCW TABLE Index Table Model 794 Installation, Operating and Maintenance Instructions Black & Webster Products Division 545 Hupp Ave. P.O. Box 831, Jackson, Michigan 49204 2009

More information

GS - Parallel Gripper

GS - Parallel Gripper 11: Double acting Patented backlash adjusting system. Long life and reliability, maintenance free. Different options for fastening. Optional magnetic sensors available on page 517. Spring closed (-NC)

More information

Parallel grippers HGPM, micro

Parallel grippers HGPM, micro Key features G6: G8: G9: stroke compensation clamping spigot flange mounting At a glance Compact, handy design With open or closed gripper jaws Versatility thanks to externally adaptable gripper fingers

More information

Hydraulic Accumulators with Back-Up Nitrogen Bottles

Hydraulic Accumulators with Back-Up Nitrogen Bottles Hydraulic Accumulators with Back-Up Nitrogen Bottles 1. GENERAL To complete the accumulator range, HYDAC provides a variety of useful accessory products. They guarantee correct installation and optimum

More information

Gripping modules Pneumatic 2-finger parallel gripper Long-stroke gripper for small components Gripping force 120 N..

Gripping modules Pneumatic 2-finger parallel gripper Long-stroke gripper for small components Gripping force 120 N.. GM Sizes 85.. 205 Mass 0.48 kg.. 2.7 kg 120 N.. 595 N Stroke per finger 16 mm.. 30 mm Workpiece weight, force-fit gripping Up to 2.3 kg Application example 3 5 3 4 2 5 2 1 1 Pneumatic double pick & place

More information

Hydro-Mech Bridge Plug

Hydro-Mech Bridge Plug Manual No: 0620000303 Revision: F Approved By: Quality Engineer Date: 2014-9-9 Hydro-Mech Bridge Plug DESCRIPTION: Map Hydro-Mech Bridge Plug is hydraulically actuated and mechanically set. Compact, with

More information

Filtered compressed air, lubricated or non-lubricated. Maximum torque on each jaw on opening at 87 psi 3.1 in-lbf 10.6 in-lbf 20.

Filtered compressed air, lubricated or non-lubricated. Maximum torque on each jaw on opening at 87 psi 3.1 in-lbf 10.6 in-lbf 20. 2-JAW SELF-CENTERING RADIAL PNEUMATIC GRIPPER (SERIES ) Double-acting. High gripping force at the end of the stroke. Maintenance-free long life and reliability. Various options for fastening. Optional

More information

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid R133 Brass high pressure regulator, suitable for compressed air, gas and liquid HELYON 5 Chemin du Jubin 6957 DARDILLY Tél. +33 () 7 5 16 7 - Fax +33 () 7 5 16 71 FEATURES High pressure regulator for cylinder

More information

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL DESCRIPTION 1. No mar 2. No mar tip 3. Housing grip 4. Trigger 5. Air inlet 6. Air inlet plug 7. Plastic board Important! It is essential that you read the

More information

DK ton, Double-acting, Die-type Crimping Tool

DK ton, Double-acting, Die-type Crimping Tool INSTRUCTION MANUAL DK6040 60-ton, Double-acting, Die-type Crimping Tool Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register

More information

pneumatic power clamps

pneumatic power clamps pneumatic power clamps Features Király Trading KFT H-1151 Budapest Mogyoród útja 12-14 E-mail:_agi@kiralytrading.hu Your requirements Power element of machines, tools and devices for the following applications:

More information

High Pressure Equipment Pressure Vessels and Reactors Index

High Pressure Equipment Pressure Vessels and Reactors Index Pressure Vessels and Reacrs High Pressure Equipment Company designs and manufactures a broad range of pressure vessels and reacrs for both bench-scale and pilot plant applications. We have over 0 standard

More information

PED 97/23/EC COMPLIANT. Up to 7.4 tons of force on contact UltraPak cartridge for long life Operates self-contained or linked

PED 97/23/EC COMPLIANT. Up to 7.4 tons of force on contact UltraPak cartridge for long life Operates self-contained or linked atalog No. 10111A High Force Nitrogen Gas prings UH eries Up to 7.4 tons of force on contact UltraPak cartridge for long life Operates self-contained or linked PED 97/23/E OMPIANT UH eries Nitrogen Gas

More information

safety Shut-Off Valve HON 721

safety Shut-Off Valve HON 721 safety Shut-Off Valve HON 7 product information serving the gas industry worldwide safety shut-off valve HON 7 safety shut-off valve HON 7 Application, Characteristics, Technical Data Application safety

More information

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator) INTRODUCTION Binks SG-2 Plus TM Pressure Cup is ideal for component spraying and industrial applications where small batch production spraying is required. The 2 qt. capacity is sufficient to complete

More information

Instruction Manual Updated 7/26/2011 Ver. 2.2

Instruction Manual Updated 7/26/2011 Ver. 2.2 4-Unit Model MB HTHP Filter Press #171-50-4: 115-Volt #171-51-4: 230-Volt Instruction Manual Updated 7/26/2011 Ver. 2.2 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele:

More information

2-JAW SELF-CENTERING PARALLEL PNEUMATIC GRIPPER (SERIES SZ)

2-JAW SELF-CENTERING PARALLEL PNEUMATIC GRIPPER (SERIES SZ) 2-JAW SELF-CENTERING PARALLEL PNEUMATIC GRIPPER (SERIES ) Double-acting. Spring closed (upon request). Patented self-centering system. Multiple mounting and porting options. Optional magnetic sensors.

More information

Directional Controls

Directional Controls Vickers Directional Controls Directional Control Valves DG3V-3-*-60 Hydraulic Operated DG17V-3-*-60 Lever Operated DG18V-3-*-60 Air Operated DG20V-3-*-60 Cam Operated DG21V-3-*-60 Plunger Operated CETOP

More information

Accessories for Sanitary Installations

Accessories for Sanitary Installations 5. Accessories for Sanitary Installations Flamco s Prescor B safety valves protect potable water systems from exceeding the maximum design operating pressure. Once the set pressure has been reached the

More information

Technical Data Sheet TI-F50 Locking Units series KFH

Technical Data Sheet TI-F50 Locking Units series KFH English translation of German original Locking Units series KF Further important practical advice is given in Operating Manual BA-F50., Rod diameter 18 mm 50 mm øz 8 L 2 6 x 6 0 min. 4x30 KF 18 to KF 32,

More information

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Parallel grippers HGPM, micro

Parallel grippers HGPM, micro Key features G6: G8: G9: with stroke compensation with clamping spigot with flange mounting At a glance Compact, handy design With open or closed gripper jaws Versatility thanks to externally adaptable

More information

IF IN DOUBT PLEASE CONTACT METROL SPRINGS LTD Tel: +44(0) Fax: +44(0)

IF IN DOUBT PLEASE CONTACT METROL SPRINGS LTD Tel: +44(0) Fax: +44(0) 1 Mounting Instructions All Nitro-Springs are factory tested prior to dispatch and will give the user many years of service. To receive the best possible life from the gas springs, the following should

More information

Micro grippers HGPM/HGWM

Micro grippers HGPM/HGWM HGPM/HGWM Miniaturised and optimised for assembly tasks Versatile 2004/10 Subject to change Products 2004/2005 1 / 1 HGPM/HGWM Key features HGWM HGPM 1 2 3 4 1 2 3 4 System product for handling and assembly

More information

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation, Operation and Maintenance Manual for Back Pressure Regulator Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN

More information

Vibration isolation system 1VIS10W. User manual

Vibration isolation system 1VIS10W. User manual Vibration isolation system 1VIS10W User manual Standa 2014 Table of contents 1. General information 3 1.1. Introduction 3 1.1.1. Safety 5 1.2. Location of the table 5 1.3. Air supply requirements 5 2.

More information

COMPACT NITROGEN DIE SYSTEMS

COMPACT NITROGEN DIE SYSTEMS COMPACT NITROGEN DIE SYSTEMS CONTENTSENTS 3 2 Compact Die Systems Fundamentals 3 Spring rates and scales 45 Standard cylinders Type CDS (3.3 100 kn) 6 Pad mounted cylinders Type CDSP (3.3 200 kn) 7 Low

More information

Up to 7.4 tons of force on contact UltraPak cartridge for long life Operates self-contained or linked

Up to 7.4 tons of force on contact UltraPak cartridge for long life Operates self-contained or linked atalog No. 10111 High Force Nitrogen Gas prings UH eries Up to 7.4 tons of force on contact UltraPak cartridge for long life Operates self-contained or linked UH eries Nitrogen Gas prings Introduction

More information

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection 1170850/1 IM-P117-36 ST Issue 1 MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection Installation and Maintenance Instructions 1. Safety information 2. General product information

More information

2-port seat valves PN25 with externally threaded connections

2-port seat valves PN25 with externally threaded connections 4 379 2-port seat valves PN25 with externally threaded connections VVG55.. Valve body bronze CC491K (Rg5) DN 15...25 (½...1 ") kvs 0.25...6.3 m3/h Stroke 5.5 mm Sets of ALG.. with threaded and ALS.. with

More information

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0 Operating Manual LTIA5E Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0 Contents 1. Safety Instructions 2. Conformity to standards 3. Technical data

More information

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm) Vickers Cartridge Valves Load Controls Screw In Cartridge Valves Pressures to 50 bar (5000 psi) Flows to 90 l/min (50 USgpm) Rev. 2/99 722 Contents MODEL DESCRIPTION TYP. APPLICATION PRESSURE bar (psi)

More information

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to: HANDBOOK Squeeze Off Unit SOU 400 Please refer any queries to: Hy Ram Engineering Co Ltd Pelham Street Mansfield Nottinghamshire NG18 2EY Telephone No: (01623) 422982 Please note all queries should state

More information

TONS! powerteam.com HEAVY LIFT CYLINDERS

TONS! powerteam.com HEAVY LIFT CYLINDERS NEW DESIGNS TONS! powerteam.com HEAVY LIFT CYLINDERS THE Precise MOST Positioning COMPREHENSIVE & ControlRANGE OF HIGH in a Responsive PRESSURE Package HEAVY LIFT CYLINDERS R_G SINGLE & DOUBLE ACTING,

More information

Pilot Operated Check Valves

Pilot Operated Check Valves Pilot Operated Check Valves These check valves allow flow in one direction and prevent flow in the reverse direction, until operated by pilot pressure to allow free reverse flow. The specified cracking

More information

BRINGING YOU THE SINCE 1980

BRINGING YOU THE SINCE 1980 BRINGING YOU THE QUALIT Y YOU DESERVE SINCE 1980 2 0 16 P R O D U C T C ATA LO G A Division of Vermont Precision Tools, Inc. QUALITY POLICY Our policy is to consistently achieve or exceed customer satisfaction

More information

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0) Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk HP690A Intensifier Panel including the following versions: Model Intensification

More information

GX-S. 2-jaw self centering radial pneumatic gripper (series GX-S) GX-S

GX-S. 2-jaw self centering radial pneumatic gripper (series GX-S) GX-S GX-S 2-jaw self centering radial pneumatic gripper (series GX-S) Double acting. Very high gripping force at the end of the stroke. Long life and reliability, maintenance free. Various options for fastening.

More information

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

STANDARD FOR CONTROL VALVE SEAT LEAKAGE 11-3 STANDARD FOR CONTROL VALVE SEAT LEAKAGE 1. PURPOSE 1.1 This standard establishes a series of seat leakage classes for control valves and defines the test procedures. 2. SCOPE & LIMITATIONS 2.1 Selection

More information

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper LOG Cost effective. Smooth. Reliable. LOG Internal Hole Gripper Light gripper made of very resistant polyamide with closed diaphragm system Field of Application Particularly suited to highly dynamic applications

More information

Certified Accuracy. Ring Force Gauge. Models and Capacities Available. Design and Principle of Operation

Certified Accuracy. Ring Force Gauge. Models and Capacities Available. Design and Principle of Operation Certified Accuracy Ring Force Gauge The accurate measurement of mechanical forces is required in hundreds of applications from a simple weighing procedure to the calibration of testing machines and load

More information

Operation Manual Piston Sensed Gas Pressure Regulators

Operation Manual Piston Sensed Gas Pressure Regulators 687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Operation Manual Piston Sensed Gas Pressure Regulators (Models KT9, KT10, Welded KT10, KT12) Table of Contents:

More information

Sizes Weight Gripping force Stroke per finger Workpiece weight Pieces : kg N mm kg

Sizes Weight Gripping force Stroke per finger Workpiece weight Pieces : kg N mm kg MPG-plus Sizes Weight Gripping force Stroke per finger Workpiece weight Pieces : 7 0.06.. 0.63 kg 25.. 350 N 1.5.. 10 mm 0.19.. 1.25 kg Application example Pneumatically driven, dual-axis pick-andplace

More information

Series MX pressure regulators 3/

Series MX pressure regulators 3/ CATALOGUE > Release 8.8 > Series MX regulators Series MX pressure regulators MX2 ports: G/8, G1/2, G/4 - MX ports: G/4, G1 Manifold ports: G1/2 (MX2 only) Modular - Available with built-in pressure gauges

More information

VACUUM REGULATORS CONTENTS

VACUUM REGULATORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

Wide opening parallel grippers Series CGLN

Wide opening parallel grippers Series CGLN CATALOGUE > s 202 Wide opening parallel grippers Series CGLN > Grippers Series CGLN Magnetic Sizes: ø 0-6 - 20-25 - 32 mm» High flexibility during mounting» High grip force» Rack and pinion synchronized

More information

3 & 4-Way Mixing & Diverting Valves

3 & 4-Way Mixing & Diverting Valves Applications: 3-Way Valve The ESBE VRG series of 3 & 4-way valves are designed to mix water to the appropriate temperature to meet the zone or system requirements within heating and cooling systems. The

More information

Compact pressure switches for gas and air

Compact pressure switches for gas and air Compact pressure es for gas and air / 5.0 Printed in Germany Edition 0.8 Nr. 9 544 6 Technical description The pressure is an adjustable compact pressure according to EN 854 for combustion plants. The

More information

Gas Spring User Information

Gas Spring User Information Gas Spring User Information Charge only with NITROGEN GAS (N2) All Special Springs nitrogen cylinders are designed with a stroke reserve from 1 to 3mm (except M90/ TBM-TBI-TEM). Therefore, the nominal

More information

Pressure regulators Manually operated Fine setting valves. Brochure

Pressure regulators Manually operated Fine setting valves. Brochure Pressure regulators Manually operated s Brochure Pressure regulators Manually operated s Qn = 9 l/min Actuating element: Push button Internal thread Poppet valve Qn = 9 l/min Actuating element: Push button

More information

HEAVY DUTY PNEUMATIC

HEAVY DUTY PNEUMATIC HEAVY DUTY PNEUMATIC Series A4 MEDIUM DUTY HYDRAULIC Series H4 PERMANENTLY LUBRICATED HEAVY DUTY PNEUMATIC Series L4 586.778.7680 SERIES A4/L4/H4 39 A4/L4/H4 FEATURES 1 1 9 9 12 8 7 5 12 3 13 4 10 2 11

More information

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94 Vickers Flow Controls Flow Controls FN, F(C)G, FRG Released 6/94 685 Table of Contents FN03/06/10 Model Series Application Data...............................................................................

More information

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0) Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk SOFT LINE CUTTER SL55 PRODUCT CODE No. 980504 INSTRUCTIONS FOR INSTALLATION,

More information

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics. Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum

More information

Catalog No. C09118A. Nitrogen Gas Spring Linked System Components

Catalog No. C09118A. Nitrogen Gas Spring Linked System Components Catalog No. C09118A Nitrogen Gas Spring Linked System Components Everything You Need to Construct a Linked System Linked Systems Introduction Numerous Piping Options Many customers recognize the benefits

More information

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version Series 44 Self-operated Pressure Regulators Type 44-0 B Pressure Reducing Valve ANSI version Application Set points from 3 to 290 psi (0.2 to 20 bar) with valves ½ NPT to 1 NPT as well as NPS ½ and 1 Pressure

More information

250 (9.84) 170 (6.69) 225 (8.85) 75 (2.95) 300 (11.81)

250 (9.84) 170 (6.69) 225 (8.85) 75 (2.95) 300 (11.81) Air bellows, single acting Ø... / inch Suitable for applications on rail vehicels Almost frictionless operation No maintenance or lubrication Weather/corrosion resistant metal parts Approvals for fire

More information

MERCER VALVE SERIES Pilot Operated THINK...MERCER FIRST MERCER VALVE CO., INC. AUTO SEAT TECHNOLOGY

MERCER VALVE SERIES Pilot Operated THINK...MERCER FIRST MERCER VALVE CO., INC. AUTO SEAT TECHNOLOGY 9500 SERIES Pilot Operated THINK...MERCER FIRST MERCER VALVE MERCER VALVE CO., INC. AUTO SEAT TECHNOLOGY 9500 Series Pilot Operated Product Overview The 9500 Series Safety Relief Valves are State of the

More information

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5. Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read

More information

Schroeder Check Test Point System

Schroeder Check Test Point System Perforated polyamide / kevlar hose, 2 mm ID, 5 mm OD, plastic dust cap. L in (mm) P (max) psi (bar) 6 (150) 10,000 (680) 12 (300) 10,000 (680) 24 (610) 10,000 (680) 36 (915) 10,000 (680) 48 (1220) 10,000

More information

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer Inflatable Packer Single & Double Single & Double Packer Dimension Wireline Packer Water Testing Packer (WTP) Packer Packer Working Pressure & Depth Chart Packer Water Hand Pump Packer Air Driven Pump

More information

Pressure reducing valve, pilot operated, Model 3DR

Pressure reducing valve, pilot operated, Model 3DR RA 26 928/06.98 Pressure reducing valve, pilot operated, Model 3DR Nominal size 16 Series 5X Maximum operating pressure 3600 PSI (250 bar) Maximum flow 58.1 GPM (220 L/min) Contents Description Page Features

More information

Standard Specifications

Standard Specifications NARM, 2 Ways of Connection Small Size Pressure Gauge ø5mm Reverse flow function available on the standard model Space Saving -B2 NARM-6A-NG Standard Specifications Fluid Proof pressure psig (MPa) Max.

More information

Берг АБ Тел. (495) , факс (495) Turning Ideas Into Engineered Solutions KAYDON RING & SEAL, INC.

Берг АБ Тел. (495) , факс (495) Turning Ideas Into Engineered Solutions KAYDON RING & SEAL, INC. Turning Ideas Into Engineered Solutions RING & SEAL, INC. K-CBS Series Circumferential Barrier Seals Kaydon s high performance circumferential barrier seals back up DGS systems with performance & economy.

More information

O P E R ATING INSTRUCTIONS FOR MODEL SPR-45 Automatic Screen and Stencil Printer

O P E R ATING INSTRUCTIONS FOR MODEL SPR-45 Automatic Screen and Stencil Printer O P E R ATING INSTRUCTIONS FOR MODEL SPR-45 Automatic Screen and Stencil Printer TABLE OF CONTENTS I. SPECIFICATIONS...3. II. SAFETY INSTRUCTIONS...4. III. INSTALLATION...5. IV. SET-UP...6. V. SYSTEM OPERATION...9.

More information

35 TON HYDRAULIC PUNCH WARNING

35 TON HYDRAULIC PUNCH WARNING OPERATORS GUIDE REL-35T-PNC 35 TON HYDRAULIC PUNCH NOTICE Sizes, weights and tool specifications listed in this manual are subject to change without notice. Please consult factory for information and updates.

More information

Gauge Valves / Multi-Port Valves & Air Distribution Manifolds

Gauge Valves / Multi-Port Valves & Air Distribution Manifolds auge Valves / Multi-Port Valves & ir istribution Manifolds OV Series Orifice valves 6,000 psi and 10,000 psi rated V Series Multi-port gauge valves 6,000 psi and 10,000 psi rated PV Series Rising plug

More information

Engineering Data Sheet

Engineering Data Sheet Page 1 of 6 CE MARKING AND THE PRESSURE EQUIPMENT DIRECTIVE 97/23/EC Valves must be installed into a well designed system and it is recommended that the system be inspected in accordance with the appropriate

More information

Subsea Safety Systems

Subsea Safety Systems Subsea Safety Systems The ELSA-HP has been developed to service the high pressure horizontal tree completion and intervention market. With systems designed and qualified up to 15,000 psi, 250 degf and

More information

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when

More information

Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Dump Valve Service Kit for Series 2300 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit

More information

Spirax SafeBloc TM DBB3 Double Block and Bleed Bellows Sealed Stop Valve. 1. Safety information. 2. General product information. 3.

Spirax SafeBloc TM DBB3 Double Block and Bleed Bellows Sealed Stop Valve. 1. Safety information. 2. General product information. 3. 1849050/3 IM-P184-09 ST Issue 3 Spirax SafeBloc TM DBB3 Double Block and Bleed Bellows Sealed Stop Valve Installation and Maintenance Instructions 1. Safety information 2. General product information 3.

More information

SB 102. Spare parts list. Hydraulic breakers. SB 102 s/n BES Construction Tools PC AB No h

SB 102. Spare parts list. Hydraulic breakers. SB 102 s/n BES Construction Tools PC AB No h SB 102 Spare parts list Hydraulic breakers SB 102 s/n BES043603 2018 Construction Tools PC AB No. 9800064201h 2018-01 General information This spare parts list applies to the following: Part number 8460030030

More information

Installation and commissioning instructions 255 series and 256 series

Installation and commissioning instructions 255 series and 256 series Installation and commissioning instructions 255 series and 256 series Table of contents 1 General information... 3 1.1 About these instructions... 3 1.2 About this product... 3 1.3 Appropriate usage...

More information

TEST SPECIFICATION NYT-909-C

TEST SPECIFICATION NYT-909-C 748 Starbuck Ave, Watertown, NY 13601 Phone: +1-315-786-5200 Engineering Fax: +1-315-786-5673 TEST SPECIFICATION NYT-909-C CODE OF TESTS FOR TESTING "AB" TEST RACK P/N 702546 & 702612 ISSUE NO. 5 1.0 THE

More information

Leak free Pipe Rupture Valve for Excavators

Leak free Pipe Rupture Valve for Excavators Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................

More information

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw. Premium Series High Quality Forged Brass Body Rust-Resistant Nickel Plated Finish Long Life Corrosion Resistant Valve Seat Economical Price & Reliable Performance Tamper-Resistant locking Screw Reduces

More information

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions 6250250/1 IM-P625-03 ST Issue 1 USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions 1. General safety information 2. General product information

More information

COMPACT NITROGEN DIE SYSTEMS

COMPACT NITROGEN DIE SYSTEMS COMPACT NITROGEN DIE SYSTEMS CONTENTSENTS 3 2 Compact Die Systems Fundamentals 3 Spring rates and scales 45 Standard cylinders Type CDS (3.3 100 kn) 6 Pad mounted cylinders Type CDSP (3.3 200 kn) 7 Low

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401 THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special

More information

Directional Valves. Hydraulic Operated Directional Valves

Directional Valves. Hydraulic Operated Directional Valves Service Data Vickers Directional Valves Hydraulic Operated Directional Valves (F*) DG3V 8 (B) ** (L) (X) (*) (*) 10 (EN**) Released 04/96 5007.03/EN/0496/S DG3V-8-*(C) - (X) - 10 Spring Centered 473726

More information

excellence of Italian engineering Field adjustable PRESSURE RELIEF VALVES

excellence of Italian engineering Field adjustable PRESSURE RELIEF VALVES excellence of Italian engineering Field adjustable PRESSURE RELIEF VALVES excellence of Italian engineering OUR MISSION: We started in 1960 as instrumentation manufacturers and we have increasingly specialized

More information

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow

More information

Full Range Pressure Compensating Variable Flow Control

Full Range Pressure Compensating Variable Flow Control Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever

More information

shutoff valves 900 Series psig Manual Shutoff Valves

shutoff valves 900 Series psig Manual Shutoff Valves 0 6000 psig Manual Shutoff Valves Features Zero leakage Protected o-ring Full flow passages Freedom from wire drawing Panel mount standard Hand wheel or toggle handle How it Works Closed O-ring seal on

More information