Control Panels & Depth Gauges
|
|
- Megan Flowers
- 6 years ago
- Views:
Transcription
1 Control Panels & Depth Gauges
2 POMMEC SCUBA REPLACEMENT SYSTEM MOBILE/PORTABLE SURFACE SUPPLIED SYSTEM (Conform IMCA D015) - Stainless steel crash proof storage frame with 4 lifting points which can hold the umbilicals, panel, radio and cylinders. - 3 or 4 industrial cylinders, mounted horizontally each with a volume of 50 litres and a working pressure of 225 Bar - Above cylinders are manifolded through the diving control panel to provide both the diver and the stand-by diver with their own dedicated air supply: 1 (or 2) cylinders for the main diver 1 cylinder for the stand-by 1 cylinder which can be used to supply either diver 2 DIVER CONTROL PANEL TYPE OFFSHORE All Pommec controlpanels are assembled with high quality material and is specially designed to be easy to use. To protect the technical part this panel is mounted in a very strong synthetic Pelican case with internal wheels on one side for easy carriage. - 2x pneumometer (depthgauges) Ø 160mm, 100 or 60 mtr, scale 0,5 msw,class 0,25-3x HP air inlet - 3x HP manometers (one for each line) - 3x pressure regulators Bar (one for each line) - 5x LP manometer - 2x LP outlet connection with JIC 6 swivel coupling(one for each diver) - 2x Pneumo outlet connection with JIC 4 coupling (one for each diver) - 'cross over' between the different lines so that at all circumstances all divers will have air - All conform the IMCA regulations and Lloyd's requirements - Certificates for the depth gauges, regulators and for the panel overall - Spare part list with Pommec references - Manual in English ** The set can be completed with a 2 diver radio of choice**
3 OFFSHORE 2 DIVER PANEL This Pommec 2 diver control panel is assembled with very high quality material and is very easy to use. To protect the technical part this panel is mounted in a very strong synthetic Pelican case with internal wheels on one side for easy carriage, these cases are really very strong, they withstand drops fully loaded of a few meters, they also withstand temperatures till 99 Celsius!!! Offshore panel Sizes: 80 x 52,5 x 30 cm 2 depth gauges 0-60 MWK complete with mirror scale, high accuracy, Ø 160 mm each 2 High pressure air supply connection 1 low pressure air supply connection Standard connectors or Quick connectors for air and pneumo 5 pressure gauges 6 special needle and ball valves 2 safety pressure regulators for the depth gauges 2 pressure regulators Bar maximum Capacity of the valves: 2000 ltr/min
4 POM 3 DIVER PANEL Pommec 3 diver controlpanel, ideal solution for those jobs with two divers in the water together with one standby diver as back up at the surface. This high quality panel is assembled in a stainless steel housing. The housing is only open at the backside, once it is fixed on a wall for instance nothing can happen to the technique on the inside. Our Panel is build according to Lloyd's register of shipping rules, which is very important for offshore use! We have equiped this panel with 3 high quality depthgauges 0-60 MWK which makes it possible for you to check all three divers depths at the same time, complete with mirrorscale, high accuracy, Ø 160 mm each. Because of the simple layout this panel is very easy to use. This panel is equiped with 3 high pressure air supplies and two low pressure air supplies, but if your request is different, say for a three diver panel with an oxygen supply, or any other configuration, please do let us know. Three diver control panel Sizes: 110 x 50 cm 3 depthgauges 0-60 MWK complete with mirrorscale, high accuracy, Ø 160 mm each 3 High pressure air supply connection 3 low pressure air supply connection quick connectors for air and pneumo 9 pressure gauges 15 special needle and ball valves 3 safety pressure regulators for the depth gauges 3 pressure regulators 1 st stage Bar 3 pressure regulators 2 nd stage Bar maximum Capacity of the valves: 2000 ltr/min
5 DCS DIVING PANELS WITH AND WITHOUT COMMUNICATIONS The Dive Control System-2A is a lightweight, portable control box for use in surface supplied air diving operations. The DCS-2A controls the diver's air supply, communications and monitors the diver's depth. It allows two divers clear push-totalk (two wire) or round robin (four wire) communications. The air supply can be either from a low pressure compressor or high-pressure cylinders. The DCS-2A's adjustable first stage regulator reduces the high-pressure air and supplies low pressure through the umbilical to the diver's breathing system. High pressure yokes permit U.S. standard scuba cylinders to be used. Low pressure air supply fittings allow for a compressor to be used as the primary air source. A complete pneumo system with dual reading gauges (both US Standard and Metric) is provided for each divers air, as well as a shut-off/bleed system that uses two high-pressure feed lines which allows changing of used cylinders without interruption of the diving operation. Optional shut off valves allow the isolation of each diver's air supply. The Communication Set is a multipurpose intercommunication system that provides reliable and clear communications between a topside operator (tender) and one or more surfacesupported divers, diving bells, personnel transfer capsules (PTC)s, recompression chambers, or other submersible systems. It supports both two-wire and four-wire diver communication configurations, and the system can be interconnected with one or more other units to support the most demanding and diverse diving requirements. A unique and secure "self-learning" battery charge and life monitor system provides battery life information and charge control for a lead acid gelcell type rechargeable battery. The Set can be easily and inexpensively modified with a radio option to support wireless tender communications. It is designed additionally to support future developing wireless underwater communications, in-water diver recall systems, navigation and positioning systems, and data transfer systems. Communications options include a headset with boom mic as well as a wireless tender remote. The DCS-2A is also available without communications.
6 AMCOMMAND I - ONE DIVER AIR CONTROL/COMMUNICATIONS Amron has used our extensive experience in building quality life support equipment and put together the finest one diver console available today. The Amcommand I has both high and low pressure inlet supply connections and can handle two separate 4500PSIG inlet sources. The compact Tescom high flow regulator is user adjustable which allows the operator to select the divers' outlet pressure depending on the helmet or mask requirements. The full size, 6" Pneumo gauge is easy to read with dual FSW/MSW scales and has the highest accuracy rating in the industry. Individual shut off valves, check valves, relief valve and 50 micron in-line filter complete the air control system. The Amcommand I includes a panel-mounted one diver radio which features both 2 and 4 wire communications capability. This 22- watt radio has an extended gel-cell rechargeable battery life, a built in universal charger, VCR compatible tape record jack and a hand held microphone. The two 6 foot HP supply whips are complete with the 'A' style yoke to fit a standard scuba bottle (CGA- 850 connection, 3000PSIG max) and internally stored in the lid. Air Control High Pressure Side Two high pressure supply connections with two color coded, 6ft SCUBA yokes and whips. The whips and yokes remain attached to the lid of the unit during storage or transit. Each input has a color coded shut off valve and a pressure gauge which allows the tender to change out the air bottles in the system. As an added safety feature, check valves on each input provide protection against back flow of air from a full bottle to the empty in case the operator forgets to close the valve when switching bottles. A high quality Tescom adjustable, non-venting regulator reduces the high pressure air to low pressure air. The regulator input is protected against contamination by a 50 micron filter and a 0-400PSIG gauge monitors the output pressure. A relief valve (factory set at 285PSIG) limits over pressurization. Low Pressure Side Input check valve permits simple switching to back-up high pressure air in the event of low pressure air failure. Back-up high pressure air supply can simply be turned on. Diver umbilical air connection is an oxygen type fitting, controlled by a quarter turn ball valve which permits unrestricted flow.
7 Communications The 2810A radio comes complete with a hand-held push-to-talk microphone which cancels top side background noise and provides clear communication to the diver. The communicator has individual volume controls for the diver and tender which provides for individual preferences of volume. Dynamic 22 watt 'voice power' insures clear communications even under difficult conditions. The radio has AC power with battery back-up power. The system can also be powered from an external 12V source or the 110/220 volt battery charger. A red LED battery condition indicator also functions for external power sources. Pneumo System The Pneumo System measures the diver depth by supplying air pressure to the pneumo hose. The heart of the pneumo system is the high precision 6" depth gauge. The gauge dial has a glare free face and is clearly marked for fast, accurate readings. Accuracy is.25%, full scale. The system has a built-in snubber for reducing pulsating and shock pressure loads to the precision gauges. The Diver Pneumo is a valve regulating type with yellow handle and controls the air supply to the pneumo fathometer system. Specifications Air Control Specifications: HP Supply Pressure: PSI HP Supply w/ DIN: 2 Source Select HP Inlet Valve: PSI Accuracy +/- 1.5% of Full Scale HP Gauge: Two (2) Check Valves prevent reverse inlet flow HP Check Valve: Two (2) Input Yokes, with 6ft. high pressure hose whips HP Yokes & Whips: 50 Micron In line HP Regulator Output: Tescom High Pressure Regulator HP Regulator Max: PSI HP Inline Filter: Cv =.06 LP Relief Valve: 4500 PSI LP Output Fitting: O2, 9/16-18 RH oxygen (B size) LP Inlet Fitting: #6 JIC Communications Specifications: Power: 110/220VAC 50/60Hz (automatic) with internal/external battery, 12VDC Battery Life: 50 Hours (approx) Frequency Response: 300Hz - 3kHz Audio Power: 22 watts per channel Pneumo Specifications: Pneumo Gauge: 6" Dual Scale FSW/76 MSW Pneumo Fitting: 02 (37 JIC optional) Panel Specifications: Panel Material: Black polyester powder coated over stainless and aluminum Graphics: Red, white and blue silk-screened Pommec BV Ampèreweg SP Hoogerheide Netherlands Tel.: +31 (0) Fax.: +31 (0) info@pommec.com
Instruction Manual for Amron International, Inc. Model 8225-HP & 8225-HP2 AMCOMMAND Il Two Diver Air Control Systems
Instruction Manual for Amron International, Inc. Model 8225-HP & 8225-HP2 AMCOMMAND Il Two Diver Air Control Systems S/N: 1380 Aspen Way, Vista California 92081-8349 United States of America Phone: (760)
More informationSTOP. Chapter 1 General Information KMDSI Products. 1.1 Introduction. EXO Full-Face Mask Manual
Chapter 1 General Information KMDSI Products EXO Full-Face Mask Manual STOP This manual will refer to location numbers in specific drawings, or in the exploded view, which is in the back of this manual.
More informationOcean Technology Systems ComBox
Undersea Systems International, Inc. dba Ocean Technology Systems ComBox Silver Bullet User s Guide Technology in Depth - NOTICE - This manual and the information contained herein are provided for use
More informationChapter 1 General Information KMDSI Products
STOP! BEFORE GOING FURTHER- SuperLite 17B This manual will refer to location numbers in specific drawings, or in the exploded view, which is in the back of this manual. These numbers are called location
More informationDrass. 700 Series Surface Diving System
Drass Tecnologie Sottomarine Surface Diving System The Surface Diving System is a complete range of equipment which provides the widest solution for air and gas mix diving. The trolley and A-Frame recovery
More informationChapter 1 General Information KMDSI Products
Kirby Morgan 37SS Chapter 1 - Introduction This manual will refer to location numbers in specific drawings, or in the exploded view, which is in the back of this manual. These numbers are called location
More informationSECTION FIVE: OP-1B (XLDS) HIGH PRESSURE AIR STORAGE SYSTEM (HPASS) 02/17/2012
HIGH PRESSURE AIR STORAGE SYSTEM (HPASS) 02/17/2012 CAUTION: BEFORE STARTING THIS PROCEDURE ENSURE THE SUPPLY REGULATORS ARE BACKED OFF COUNTER CLOCKWISE UNTIL THE KNOBS SPIN FREELY AND THE DIVERS PNEUMOFATHOMETER
More informationDive Control System - 2A
Dive Control System - 2A Operations and Maintenance Manual S A N TA B A R B A R A, I A C A L I F O R N Diving Systems International 425 Garden Street Santa Barbara, California United States of America
More informationtake a deep breath... Dependable high quality breathing air compressors
take a deep breath... Dependable high quality breathing air compressors IN THE LEAGUE OF ITS OWN... SEACOMAIR manufacture a dependable high quality breathing air compressors, designed for continuous duty
More informationDocument Title : Air Diving Procedures Manual. Asia Divers Limited. Air Diving Procedures Manual DIV-MA Copyright
Asia Divers Limited Document Title : Air Diving Procedures Manual Doc. No : DIV-MA-0002 Page : 1 of 43 Rev : 0 Date : 06 th July 2001 Asia Divers Limited Air Diving Procedures Manual DIV-MA-0002 Copyright
More informationDF-550E PROCESS ANALYSERS APPLICATIONS FEATURES
PROCESS ANALYSERS DF-550E The DF-550E Nano Trace oxygen analyser is a Coulometric sensor based analyser designed to measure oxygen as a contaminant at ultra trace levels in ultra high purity electronic
More informationAppendix Breathing Gas Requirements EXO Balance Regulator Full-Face Mask
Appendix Breathing Gas Requirements EXO Balance Regulator Full-Face Mask If you have any questions regarding proper set-up, operation, or maintenance of your Kirby Morgan mask contact KMDSI (850) 928-7772
More informationDIVER COMMUNICATIONS: DIVE PANEL: EMERGENCY BREATHING APPARATUS: DIMENSIONS: ANALYSIS: ACCESS: DECK & VESSEL COMMUNICATIONS: GAS PIPEWORK:
Dive Control The Vertech containerised Dive Control unit provides a complete solution to managing every aspect for the ongoing dive operation. The dive control is split into two sections allowing for separate
More informationTechnical Diving Equipment
POMMEC LARS SYSTEM EASILY CONVERTED TO WET BELL SYSTEM POMMEC 2 DIVER LAUNCH AND RECOVERY SYSTEM WITH DIVING BASKET This Launch and Recovery System is specifically designed to provide a compact option
More informationInstrumentation Catalogue
Hydraulic & Offshore Supplies Instrumentation Catalogue YOUR GATEWAY TO GLOBAL SUPPLY HOSE ASSEMBLIES PRESSURE TESTING WALFORM EQUIPMENT PACKAGES FLANGES PIPE & TUBE Hydraulic & Of f shore Supplies Specialist
More informationMANUAL GAS MANIFOLDS
MANUAL GAS MANIFOLDS Phoenix Pipeline Products Limited. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com
More informationManifolds & pressure reducing sets
Manifolds & pressure reducing sets Automatic Changeover Manifold (Electronic) Providing continuous supply of medical gases Pneumatech Medical Gas Solutions (PMGS) PureGAS Manifolds provide a duty or standby
More informationChlorinator MODEL MK-I
Chlorinator MODEL MK-I The New model MK- I is semi automatic gas type. Vacuum operated Solution feed Chlorinator designed to provide a continues & measured quantity of gas while in operation. It is suitable
More informationCommon Discrepancies Uncovered on ADCI Diving Contractor & Training Program Audits
Common Discrepancies Uncovered on ADCI Diving Contractor & Training Program Audits Ways to Set Your Company or School Up For Success on ADCI Audits and Reduce Costs In most instances, all discrepancies
More informationwww.ricelake.com/condec 888-295-8475 UPC5000 PRESSURE CALIBRATION STANDARD Designed for calibrating transmitters, transducers, gauges and other pressure sensitive devices onsite, the portable UPC5000 is
More informationCAPITAL CONTROLS SERIES NXT3000
CAPITAL CONTROLS SERIES NXT3000 Modular design gas feed system with self contained automatic switchover capability. The Series NXT3000 Gas Feed System is a family of vacuumoperated, solution-feed gas dispensing
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete
More informationOperation and Maintenance Manual for the Dive Control Helium Speech Unscrambler
Operation and Maintenance Manual for the Dive Control Helium Speech Unscrambler Part Number: CO363AY Document Number: CO-OM-248 Revision: 6 (Intentionally Blank) APPROVAL SHEET Document Information Advitium
More informationUser Manual For Amron International Diving Supply, Inc.
User Manual For Amron International Diving Supply, Inc. Model 2840R/24/XX Series 4- Diver Rack Mount Communicator S/N This manual and the information contained herein are provided for use as an operation
More informationDIVATOR THE COMPLETE DIVING SYSTEM INTERSPIRO PRODUCT CATALOG
DIVATOR THE COMPLETE DIVING SYSTEM INTERSPIRO PRODUCT CATALOG 2009 Interspiro AB, Sweden. This publication contains or refers to proprietary information which is protected by copyright. All rights are
More informationAUTOMATIC GAS MANIFOLDS
AUTOMATIC GAS MANIFOLDS Phoenix Pipeline Products Limited. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com
More informationGo further, go deeper
Go further, go deeper Small footprint 13X16 m Deck layout reduced on minimum 46-9 1/2 From 6 to 12 divers Easily modifiable 1 to 3 chambers can be set up 43-11 Less expensive than a DSV Mobilized in 4
More informationUser Guide For MK3-KMDSI Communicator Two-Diver Air Intercom (Communicator P/N )
User Guide For MK3-KMDSI Communicator Two-Diver Air Intercom (Communicator P/N 415-107) Document #160502001 Document P/N 100-401 SuperMask, Kirby Morgan, DSI, Diving Systems International, EXO, SuperFlow
More informationWork Horses of the Breathing Air Industry
High Pressure Breathing Air Equipment Work Horses of the Breathing Air Industry Pegasus Compressor The Pegasus vertically enclosed compressor is a full-featured system that incorporates the latest technology
More informationDescription Advanced Features Typical Applications
Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied
More informationBUBBLER CONTROL SYSTEM
BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air
More informationFRAGMENTATION INSTRUCTION & OPERATION HANDBOOK
FRAGMENTATION INSTRUCTION & OPERATION HANDBOOK Doc. Jordair FRAGMENTATION-MANUAL WARNING! HIGH PRESSURE UNITS Under no circumstances should the fill stations be operated with the safety relief valves removed
More informationTECHNICAL DATA. Trimpac 257a. September 16, 2013
September 16, 2013 Trimpac 257a 1. DESCrIpTION DESCRIPTION The Viking Double SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-2 and D-2B used with either a Model E or F Deluge Valve (A.1), a Viking
More informationCapital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.
Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability. The Series NXT3000 Gas Feed System is a family of vacuum-operated, solution-feed gas
More informationDiving Made Easy. F. Arguello. F.Arguello
Diving Made Easy F. Arguello F.Arguello www.yachtdiver.com Battery Diving System Our new Variable Speed (VS) technology has resulted in the world s first floating battery-powered hookah systems capable
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete
More informationSABRE AIRLINE BREATHING APPARATUS
SABRE AIRLINE BREATHING APPARATUS Modulair The Sabre Modulair is a compact, easy to use airline trolley system designed to provide portable clean air in restricted access areas. Versatile and robust, it
More informationPAINTBALL
02012 www.nuvair.com PAINTBALL Table of Contents Ordering Ordering...3 High Pressure Compressors Coltri/Nuvair Portable... Coltri/Nuvair Compact Portable...5 Coltri/Nuvair Standard Electric...6 Coltri/Nuvair
More informationDräger PAS AirPack 2 Compressed Air Breathing Apparatus
Dräger PAS AirPack 2 Compressed Air Breathing Apparatus Designed using leading technology and materials, Dräger s range of heavy-duty airline apparatus is ideal for use where an extended duration of breathing
More informationADCI Consensus Standards - GAP Analysis Rev. 6 and 6.1 April 2, 2014
ADCI CS Rev. 6 (2011) ADCI CS Rev. 6.1 (2014) Section 1.0 General Provisions IMPLEMENTATION OF CERTIFICATION AND EQUIPMENT REQUIREMENTS Superscripts 1- Compliance within 6 mos. 2- Compliance within 12
More informationKey Features & Advantages of JEHA MK IV (5,000 PSI Hydraulic Test Stands)
Key Features & Advantages of JEHA MK IV (5,000 PSI Hydraulic Test Stands) The key reasons why MRO Facility now requires 5,000 PSI Hydraulic Test Stand are as follows: 1) New generation commercial aircraft
More informationTECHNICAL MANUAL OPERATOR, UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL
Operator PMCS 2-9 TECHNICAL MANUAL OPERATOR, UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL TRAILER MOUNTED TYPE I MANIFOLD SERVICING UNIT (NSN 4220-01-005-0704) AND TRAILER MOUNTED TYPE
More informationPumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out
PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL
More informationCompact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ
Compact Regulator 2 Series 2. MPa compatible, piston type compact regulator V SR X AP1 Compatible with inlet supply pressure of 2. MPa Employs a knob shape for easy operation Compact type (face to face
More informationDräger PAS AirPack 1 Compressed Air Breathing Apparatus
Dräger PAS AirPack 1 Compressed Air Breathing Apparatus Designed using leading technology and materials, Dräger s range of heavy-duty airline apparatus is ideal for use where an extended duration of breathing
More informationModel PSI Compressor with 3-Gallon Air Tank 12VDC
Model 6350 150 PSI Compressor with 3-Gallon Air Tank 12VDC IMPORTANT: It is essential that you and any other operator of this product read and understandd the contents of this manual before installing
More informationAquacom Diving Equipment
Aquacom Diving Equipment Tough, powerful and a must for professional search and rescue teams, the Aquacom system ensures clear communication between underwater divers and surface control. D-27802-2009
More informationSG1 Series Regulators - Pressure Reducing
SG1 Series Regulators - Pressure Reducing DSG131X Specifications For questions about this product, please consult TESCOM. OPERATING PARAMETERS Pressure rating per criteria of CGA E-; ASME B31; ASME BPVC
More informationCompressors for Paintball and Air Guns Catalog. The most convenient, efficient and effective way to fill your high pressure tanks.
Compressors for Paintball and Air Guns Catalog The most convenient, efficient and effective way to fill your high pressure tanks. Rev. 0.19 TABLE OF CONTENTS Ordering... 1 High Pressure Compressors Coltri
More informationUSER GUIDE. Fog Generator. ATMOSPHERE APS Series Haze Generator. MAX APS Series. No: , Revision A/d
ATMOSPHERE APS Series Haze Generator MAX APS Series Fog Generator USER GUIDE No: 120815, Revision A/d MADE IN CANADA FABRIQUÉ AU CANADA Les Générateurs de Brouillard Ltée / Fog Generators Ltd 10301 avenue
More informationStorage Systems and Accessories
Storage Systems and Accessories High Pressure Air and Inert Gases 4500-6000 PSIG DOT and ASME Cylinders High Pressure Storage Systems If an application requires storage, either in the form of a single
More informationTECHNICAL DATA. Trimpac 256a. October 31, 2013
October 31, 2013 Trimpac 256a 1. DESCRIPTION The Viking SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-1 and D- 1B used with either a Model E or F Deluge Valve (A.1), a Viking Easy Riser check valve
More informationSPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION
DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds
More informationScanFoam. Cleaning Equipment ApS. w w w. s c a n f o a m. c o m
ScanFoam Cleaning Equipment ApS w w w. s c a n f o a m. c o m Units List of Equipment 2015-06A ScanFoam ApS Skanderborg Denmark Phone: +45 86 57 25 99 Fax: +45 86 57 20 86 E-mail: anders.christensen@scanfoam.com
More informationColumbus Instruments
0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011
More informationHP/UHP Spring-Loaded Regulator
Description HP (High Purity) and UHP (Ultra High Purity) products are for service where the product must be kept free of contamination. The design is kept simple to minimise dead areas where contaminants
More informationDPC-30 DPC-100. Reference Manual
DPC-30 DPC-100 Reference Manual 1. Introduction 1.1 Description The Martel DPC Digital Pneumatic Calibrator improves upon traditional dial gauge pneumatic calibrators. The Martel DPC improves accuracy,
More informationHigh Pressure Breathing Air Compressors
High Pressure Breathing Air Compressors [ Full variety for different applications] MSA offers a comprehensive range of high pressure breathing air compressors for both the firefighting and diving market,
More informationMarschalk Model # 94000
Marschalk Model # 94000 12-volt DC Portable oil-less Air Compressor Operation Manual 27250006 REV 1 9/13/05 Table of Contents CHAPTER 1: SYSTEM DESCRIPTION... 5 FUNCTION AND THEORY... 5 SYSTEM COMPONENTS...
More informationSUBMARINE MANUFACTURING & PRODUCTS LTD
SUBMARINE MANUFACTURING & PRODUCTS LTD Worldwide Suppliers of Diving, Hyperbaric and Subsea Equipment Blackpool Road Newton Preston Lancashire PR4 3RE Telephone: +44-1772 687775 Fax: +44-1772 687774 Web
More informationRG3100 and RG3100Ice Regulator System
RG3100 and RG3100Ice Regulator System User Guide www.diverite.com Date of purchase: www.diverite.com RG1208-5 & RG1208-5Ice www.diverite.com First Stage Regulator Product Description The RG1208-5 and RG1208-5Ice
More informationChemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200
Specification Bulletin (rev.01) Series CH4200 Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200 Easy, fast& accurate digital with 11 points calibration Laser sensor offering actual feed
More informationRIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]
RIX COMPRESSORS MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230 November 21, 2002 APPLICABILITY [ A] INTRODUCTION Safety This electromechanical equipment is designed to produce high pressure gas.
More informationOur scope......your choice. An overview of the BAUER breathing air products
Our scope......your choice An overview of the BAUER breathing air products Distinctive features of BAUER Kompressoren BAUER equals more than 65 years of specialized knowledge and experience BAUER has it
More informationPressurization Equipment
Dehydration Methods Elliptical waveguide, air dielectric coaxial and rigid line should be pressurized with dry air or dry inert gas in order to prevent moisture condensation and the resultant degradation
More informationTECHNICAL DATA. Q = C v P S
Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction
More informationDF-310E PROCESS ANALYSERS APPLICATIONS FEATURES
PROCESS ANALYSERS DF-310E The DF-310E is a Coulometric sensor based oxygen analyzer designed to measure trace and percent level oxygen in pure and multi-gas backgrounds for process and quality control
More informationwww.ompressedairsystems.com ultra-high purity nitrogen generators nitrogen purity: 95% to 99.999% www.ompressedairsystems.com ultra-high purity nitrogen generators nitrogen purity: 95% to 99.999% Leading
More informationWorkhorse-15 Oxygen Generator
11436 Sorrento Valley Road, San Diego CA 92121 USA 858-558-0202 Fax 858-558-1915 Workhorse-15 Oxygen Generator Model No. 5719, 5727, 5735 for Domestic and International Units Part number 1432 Revision
More informationPlant, components and devices for very high and high pressures (7000 bar and over)
Plant, components and devices for very high and high pressures (7000 bar and over) HIGH PRESSURE GAS BOOSTER INTRODUCTION Multi-coupling system gas booster operate on the simple but efficient principle
More informationInstruction Manual Updated 7/26/2011 Ver. 2.2
4-Unit Model MB HTHP Filter Press #171-50-4: 115-Volt #171-51-4: 230-Volt Instruction Manual Updated 7/26/2011 Ver. 2.2 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele:
More information300 Held Drive Northampton Pa
300 Held Drive Northampton Pa 18067 610.262.6090 June 10, 2015 Recommended testing for verifying device performance. Intervals of testing are to be set by the Healthcare Provider / Dealer. Table of Contents
More informationInformation Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100
Information Sheet PlasmaPro Estrelas100 About this information sheet This data sheet provides basic information about the installation of a PlasmaPro Estrelas100 tool. Some of the information in this sheet
More informationInert Air (N2) Systems Manual
INSTRUCTION MANUAL Inert Air (N2) Systems Manual N2-MANUAL 2.10 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. GENERAL INFORMATION Positive pressure nitrogen gas pressurizing
More information3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289
3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for
More informationAllspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)
Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk HP690A Intensifier Panel including the following versions: Model Intensification
More informationProduct Range. High performance and economic high pressure solutions Made in Germany
Product Range Purification Storage Filling Panels Nitrox/Trimix High performance and economic high pressure solutions Made in Germany www.lw-compressors.com 2 Lenhardt & Wagner Solid Growth Lenhardt &
More informationUniversal Valve Company Inc
Universal Valve Company Inc 800-223-0741 www.universalvalve.com 1975-FA34 (Air Tower Troubleshooting Manual) Overview This manual has been arranged as a tool for diagnosing, and repairing Free Air Universal
More information7. TDI Advanced Wreck Diver Course
7. TDI Advanced Wreck Diver Course 7.1 Introduction This course provides training and experience to competently conduct advanced wreck dives. This program includes penetration skills and techniques. Depths
More informationUNDERSEA LTD. SERVING THE DIVING INDUSTRY SINCE CATALOGUE 2017 Issue 1 (Updated 17/07/2017)
UNDERSEA LTD. SERVING THE DIVING INDUSTRY SINCE 1970 CATALOGUE 2017 Issue 1 (Updated 17/07/2017) EBBLAKE INDUSTRIAL ESTATE, VERWOOD, DORSET. U.K. BH31 6BB TELEPHONE : 01202 82 20 25 TELEFAX : 01202 82
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated
More informationUser s Guide. Vacuum Controller for liquid delivery systems
Flow Control User s Guide Vacuum Controller for liquid delivery systems Precise Vacuum Control throughout the experiment Flow control Compatible with any perfusion system Ideal for Small Volume Delivery
More informationFirst Stage Regulators
DOMESTIC First stage regulators are typically used to reduce tank pressure to an intermediate pressure, usually 5 to 10 PSI for further pressure reduction by a second stage regulator located closer to
More information10. TDI Advanced Trimix Instructor Course
10. TDI Advanced Trimix Instructor Course 10.1Introduction The TDI Advanced Trimix Instructor Course provides the training required to competently and safely teach breathing gases containing helium for
More informationVariable Area Flow Meters
Variable Area Flow Meters Over sixty years of variable area meter expertise Brooks started designing and manufacturing variable area (VA) meters, also referred to as rotameters, in 1946. Now, with more
More informationModel 106 DPI "Micro-switch" Installation and Operating Instructions
Mid-West Instrument Model 106 DPI "Micro-switch" Installation and Operating Instructions BULLETIN NO. IM116DPImicro/09A Replaces --- INSPECTION Before installation carefully check the Model Number on each
More informationAIR-SAVER G1 AIR-SAVER G2 LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS
AIR-SAVER G1 AIR-SAVER G2 LOCATOR-EV ENVIRONMENT ADDING VALUE SAFEGUARD RELIABLE COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS Air saving products INDEX Chapter Content
More informationAIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express
AIR DRIVEN Gas Boosters & SYSTEMS Accepting VISA, MasterCard and American Express Gas Boosters AIR DRIVEN FROM 30 PSI TO 21,750 PSI MAXIMATOR Maximator gas boosters are an excellent alternative to high
More informationOperating Manual. Model BAC-30RT30/BAC-30DC
Model BAC-30RT30/BAC-30DC Manual No. BAC012 (Rev 1 October 2002) Operating Manual AIR SYSTEMS INTERNATIONAL, INC. 829 Juniper Crescent, Chesapeake, Va., 23320 Telephone (757) 424-3967 Toll Free 1-800-866-8100
More informationMASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS
MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS Using state-of-the-art measuring and microprocessor technologies, Advanced has assembled a series of systems which can measure mass
More informationBERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features
Level Control Valve with Altitude Pilot High level reservoirs & water towers Energy cost critical systems Systems with poor water quality Inherent refreshing Level sustaining at reservoir outlet The Level
More informationGas Boosters & Systems
DRIVEN Gas Boosters & Systems SINGLE ACTING - SINGLE STAGE PRESSURES UP TO 10,875 psi DOUBLE ACTING- SINGLE STAGE PRESSURES UP TO 21,750 psi TWO STAGE PRESSURES UP TO 21,750 psi DOUBLE HEAD - SINGLE AND
More informationDosing & Granudos. Controllers. Chemical Storage. Chemical. Dosing &
C hemical Dosing & Controllers Granudos Chemical Dosing & Controllers Controllers Chemical Storage Granudos Granudos 10-CPR Touch Granudos 10-CPR Touch swimming pool disinfection system using IQ Granu-Chlor
More informationtel: fax: web:
Tri-Flex 2 Five-Cell Permeability Test System For high volume commercial laboratory testing, the Tri-Flex 2 Five-Cell Permeability Test System offers the user the capabilities to test up to five samples
More informationBreathing Systems Inc.
Life Support System Model 2000/5000 Operations and Maintenance User Instruction 0158 EC-Guideline 89/686/EWG Certificate Nr. 5640 A/06/9 PSA NIOSH Certificate TC-13F-360 Copyright October 2016 Page 2 of
More informationair driven Standard air gas liquid for high pressure: contents Chatsworth, California, USA
air driven Standard sp-100b system packages for high pressure: air gas liquid contents Standard Liquid Pump Packages 2, 3 Standard Gas Booster Packages 4, 5 Standard Air Pressure Amplifier Packages 6 Custom
More informationAdvantage 4000 Abrasi-Blast Respirator
Advantage 4000 Abrasi-Blast Respirator Features Constant Flow Air-Line Respirator and Constant Flow Duo-Flo Respirator options Choice of shoulder length or waist length hoods to meet various blasting applications
More informationThe Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times
Tseries Series AB AB Air Air Boosters Boosters The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times.01/1 MANIFOLD MOUNTED VALVES FOR EASY SERVICING
More informationP3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features
P3000 Series Pneumatic Deadweight Testers P3000 Technical Data Features Pressure ranges from Vacuum through 2 000 psi (140 bar) Accuracy better than 0.015 % of reading. (Increased accuracy option of 0.008
More informationBIMBAR INFLATABLE PACKERS AND ACCESSORIES
BIMBAR INFLATABLE PACKERS AND ACCESSORIES Geopro supplies a complete range of inflatable packers in nine different diameters from 28 up to 170mm. All our packers made of BIMBAR rubber technology are reinforced
More information