DIVER COMMUNICATIONS: DIVE PANEL: EMERGENCY BREATHING APPARATUS: DIMENSIONS: ANALYSIS: ACCESS: DECK & VESSEL COMMUNICATIONS: GAS PIPEWORK:

Size: px
Start display at page:

Download "DIVER COMMUNICATIONS: DIVE PANEL: EMERGENCY BREATHING APPARATUS: DIMENSIONS: ANALYSIS: ACCESS: DECK & VESSEL COMMUNICATIONS: GAS PIPEWORK:"

Transcription

1 Dive Control The Vertech containerised Dive Control unit provides a complete solution to managing every aspect for the ongoing dive operation. The dive control is split into two sections allowing for separate working areas for the dive supervisor and the inspection coordinator/engineer. The dive control room is fitted with a Nitrox dive control panel, full duplex (round-robin) communications unit, diver depth data logging system, digital video recording blackbox unit, video correction equipment and associated system safety equipment that complies (and exceeds) the requirements from IMCA DO23. The inspection control room is fitted with inspection level digital video recording systems, video overlay equipment, a communications station to the inspection diver and room for task specific inspection equipment integration. The unit is extremely portable and can be rapidly mobilised as it has all equipment fitted within a standard 20 DNV offshore container and all service connectors fitted to a penetrator panel in the container wall.

2 DIVE PANEL: The panel allows the diving supervisor to individually control the primary, secondary and therapeutic gas supplies to each diver and to individually monitor the exact depth and dive time of the divers. The panel is equipped as follows: 3 x Surface mount depth gauges, Mirror band with dual scale (0 100msw and 0-330fsw) 0.25% accurate across full scale. The divers umbilical connect to a penetration plate for quick mobilization and demobilization. The Divers Gas supply is 6 JIC and 4 JIC for Pneumo supply. Each Diver has the following supplies: Primary Nitrox supply Back up Nitrox supply Back up 21/79 Nitrox supply Safety valves are fitted to the Pneumo gas supply for protection of the Divers Gauge. Divers Breathing gauge is supplied on the divers manifold downstream of the valve and isolated by a dedicated valve. ANALYSIS: There are 3 oxygen analysers fitted for the dive panel (one per diver). The analyser take off is from the divers supply gas. The feed comes from the downstream feed to the diver. The analyser is fitted with high and low alarms. There is also an ambient control room analyser is set to pick up any low oxygen or high oxygen concentrations. DECK & VESSEL COMMUNICATIONS: Deck communications are from a 4 channel base station with remote outstations located around the dive system (mounted in the machinery space, Main LARS control, Standby LARS control and decompression chamber control). In addition this unit can be setup for separate dedicated links to the Bridge, ROV control room and crane operator. DIVER COMMUNICATIONS: Diver communications is via a digitally controlled analogue communications unit. This unit is setup for superior powered analogue communications from custom microphones fitted to the divers helmet. The unit also has full duplex selectable communications links allowing divers to communicate with each other during dives while still keeping the supervisor in control of all ongoing communications. In addition the unit has a dedicated outstation for connecting in the inspection coordinator to facilitate communication and recording required for inspection tasks. EMERGENCY BREATHING APPARATUS: The control room is fitted with an emergency breathing apparatus set mounted within a dedicated storage unit. The set is a self-contained unit with a pressurised gas cylinder for clean air supply. The set is fitted with a link to the diver communications unit. DIMENSIONS: Length: 6.06m Height: 2.44m Width: 2.44m Tare Weight: 8Te Max Weight: 20Te ACCESS: The container is fitted with 2 personal access doors complete with windows and locking mechanisms. The personnel access doors are located along one of the long sides (direct access into the dive control area) and on the short side (access adjacent to the inspection area).the container double doors provide access to the standby diver and umbilical storage area. GAS PIPEWORK: Gas pipework is made from Tungum tubing and is piped directly to the penetration plate and connected to standard JIC end fittings. All pipework and fittings are cleaned to a high standard required for Nitrox use. VIDEO DISPLAY & RECORDING SYSTEM: The Diver video display and recording system includes a 19 Rack mounted Blackbox DVR Recorder, topside light and camera controllers, video Quad display, Video Isolation transformers, Video and audio distribution amplifiers and display monitors. There is a second DVR located within the inspection control office and provides a means of recording inspection quality level video. For more information please contact: Offshore Diving Manager: Alan Melia +44 (0) alan.melia@gegroup.com Vertech UK Unit H1, Aberdeen Science & Energy Park Claymore Avenue, Scotland AB23 8GW Tel: +44 (0)

3 Deck Decompression Chamber The Vertech containerised Deck Decompression Chamber (DDC) unit provides a means of supporting emergency and/or surface decompression for offshore surface supplied diving operations in a compact and efficient package. This is achieved by combining the decompression chamber hull, its control system, emergency gas storage and support equipment into a single containerised unit. The unit chamber hull and viewports have been designed and built in accordance with ASME VIII, ASME PVHO & Lloyds Register PD5500 (as applicable). The system fit out has be completed to a high standard and far exceeds the requirements of the IMCA D023 - DESIGN for Surface Orientated (Air) Diving Systems. The unit is extremely portable and can be rapidly mobilised as it has all equipment fitted within a standard 20' DNV A60 offshore unit. The unit has been designed to keep all critical systems operational in the event of a fire or gas shutdown scenario.

4 1800 CHAMBER HULL: Design Code: BS/PD5500 Certification Authority: Lloyd s Register Maximum Depth Rating: 100 MSW / 334 FSW Chamber Diameter: 1800mm / 72 Medical Lock: 10 (250mm) bayonettype enclosure fitted with safety interlocks VIEWPORTS: Design Code: Maximum Depth Rating: Viewport Diameter: CHAMBER CONTROL PANEL: ASME PVHO MSW / 334 FSW 250mm The chamber is fitted with a control panel mounted on the dished end of the hull. The panel is fitted with 2 supplies (main & emergency) for blow down to each lock. In addition the panel is fitted for control of supply for the BIBs system to each lock and pipework for gas analysis. MONITORING: The control panel is fitted with 2x display monitors for viewing the chamber internal. The main lock is fitted with an internal camera and the entry lock is fitted with a camera mounted over the viewport. EMERGENCY BREATHING APPARATUS: The control room is fitted with an emergency breathing apparatus set mounted within a dedicated storage unit. The set is a self-contained unit with a pressurised gas cylinder for clean air supply. The set is fitted with a link to the diver communications unit. 16-CYLINDER GAS BANK: A 16-cylinder (50 litre) 200 Bar gas bank is fitted for emergency pressurisation of the DDC. The gas bank is split into two independent 8-cylinder supplies ensuring that there is a main and back up emergency source for the DDC. For more information please contact: Offshore Diving Manager: Alan Melia +44 (0) alan.melia@gegroup.com Vertech UK Unit H1, Aberdeen Science & Energy Park Claymore Avenue, Scotland AB23 8GW Tel: +44 (0) ANALYSIS: There is a combined electronic oxygen and carbon dioxide analyser for monitoring of the chamber environment. The analyser is selectable between the main lock, entry lock and BIBs supply There is also an ambient control room analyser is set to pick up any low oxygen or high oxygen concentrations within the control room. CONTAINER STRUCTURE: The container is a DNV2.7-1 certified structure and lifting equipment. The container is insulated on all sides and is fitted with an internal bulkhead separation just inside the container double doors. ACCESS: The container is fitted with an external access door to the chamber control area. The door is located on the opposite end to the container double door and is f i tted wi th a window. In addition there is a man access door in the container door bulkhead for access down the side of the chamber. The chamber access doorway is fitted in the bulkhead and all chamber doors are 700mm diameter, nonlocking doors with securing points for the open position. CONTAINER DETAILS: Length: 6.06m Height: 2.44m Width: 2.44m Tare Weight: 11Te Max Gross Weight: 20Te AIR CONDITIONING/ HEATING: The air-conditioner is of the split-unit type with the evaporator situated internally and the condensing coil situated externally of the insulated environment. The air conditioner unit is suitable for heating and cooling and has a variable speed control. Permanently mounted in an enclosure that will protect the external compressor and condensing coil. Refrigerant piping will link the compressor to the internal evaporator. POWER: The main power supply to the container is through a sealed penetration system and fed directly into the main ExD distribution and control enclosure (440VAC or 380VAC). Incoming Power Transformers reduce 440V/380V to 220VAC/110VAC for control room use which is then fur ther reduced and converted to 12/24VDC for chamber internal use. All consumers are fed from double-pole isolating circuit breakers. All multi-purpose appliance outlets (plugs) are protected by 30mA residual current circuit breakers.

5 Machinery Container The Vertech containerised diving machinery unit provides a single container solution to providing all required equipment necessary for the ongoing dive operation. The machinery unit is split into two sections, this allows for a separate workshop and stores from the machinery space. The machinery unit is fitted with primary and backup hot water units, high pressure breathing air compressor and diver tooling hydraulic power unit. In addition the container houses the primary and secondary 440V 3- phase power distribution unit for the rest of the dive spread as well as suitable cooling circulation fans for all equipment. The stores/workshop area has lockable cabinets and shelves for storage of all spares and tools required by the Dive Technicians to carry out all planned and unplanned maintenance to keep the dive system operational at all times. The unit is extremely portable and can be rapidly mobilised as it has all equipment fitted within a standard 20' DNV A0 offshore container and all service connectors fitted to a penetrator panel in the container wall.

6 HOT WATER UNIT: The primary electrical water heater will supply warm seawater to maintain a comfortable temperature for 3 divers simultaneously. Water supply from vessel water supply or a submersible pump Delivery rate of 45 l/min continuous to all divers Power requirements: 144kW max, 440V, 280Amps Typical outlet temperature range: 40 to 60 C at divers Note: Due to power requirements, the Hot Water Unit requires a separate power supply feed from the rest of the diving system. STANDBY HOT WATER UNIT: The secondary standby electrical heater will store warm fresh water to be ready to supply to the diver in the event of primary unit failure. Stored water supply of 400ltrs Delivery rate of 45 l/min continuous to all divers Backup time: 6-8mins Typical storage temperature range: 40 to 60 C HIGH PRESSURE COMPRESSOR: The Lenhardt & Wagner 450E compressor is an electrically driven medium capacity, breathing air compressor. Delivery Rate of 450 L/min Working Pressure of 200 BAR (2900 PSI) Automatic Condensate Drain Breathing air delivered is in compliance with EN SUBMERSIBLE PUMPS: The submersible pump can be deployed over the side of a vessel or into the Moonpool and feeds the primary hot water unit. The pump is powered and controlled via a control system located within the machinery container. Flow Rate: 50lpm at 5-6 bar Electrical Power Supply: 1.1kW max, 440V, >2Amps TOOLING HYDRAULIC POWER UNIT: The HPU is for use with underwater hydraulic tools. It is removable from the machinery container. The unit consists of the following: 20.5kW Power pack in an offshore lifting frame Adjustable pressure range: bar Max Flow Rate 56 l/min Electrical deck plugs connection (for external use) POWER DISTRIBUTION UNIT: The main power supply to the container is via an externally mounted bulkhead appliance inlet (440VAC or 380VAC) of 125amp. The backup power supply is via a 63amp appliance inlet (440VAC or 380VAC). The power source is selectable from the junction box located within the container. The distribution unit supplies power from either the primary or secondary source to all machinery within the container as well as power to; the decompression chamber container, dive control container, submersible pump and the 2 launch & recovery units. CONTAINER STRUCTURE: The container is a DNV2.7-1 certified structure and lifting equipment. The container is insulated on all sides and is fitted with an internal bulkhead separation between the machinery space and the workshop/ stores areas. ACCESS: The container is fitted with an external access door to the stores and workshop area. The door is located on the opposite end to the container double door and is fitted wi th a window. Access to the machinery space is via the main double doors of the container. CONTAINER DETAILS: Length: 6.06m Height: 2.44m Width: 2.44m Tare Weight: 7Te Max Gross Weight: 20Te For more information please contact: Offshore Diving Manager: Alan Melia +44 (0) alan.melia@gegroup.com Vertech UK Unit H1, Aberdeen Science & Energy Park Claymore Avenue, Scotland AB23 8GW Tel: +44 (0)

7 Divers Launch & Recovery System The Vertech Launch and Recovery System (LARS) provide a means for the safe entry and exit of the water by the divers during diving operations (primary unit) or in an emergency (secondary unit). The units are fitted with man riding hydraulic powered winches designed specifically for diving applications in a marine environment. The units are built to and classed under DNV standard and are also compliant with IMCA and LOLER requirements (where applicable). These units are also fitted with redundant hydraulic power units and electrical control systems and motors. These units are extremely portable and can be rapidly mobilised. They are also design to fit within a standard 20 offshore/shipping container should they require to be shipped to a platform or overseas.

8 HYDRAULIC POWER UNIT (HPU): The hydraulic power pack is situated on the A-Frame skid directly beneath the winch and control station. The power pack consists of the following: Main pressure compensated piston pump and motor rated as follows: 11kW power output 24 L/min at 210 bar (flow at 440V/60Hz) 380/440V 50/60Hz Backup fixed displacement gear pump and motor rated as follows: 9.2kW power output 19 L/min at 210 bar (flow at 440V/60Hz) 380/440V 50/60hz 1 x 150 litre main hydraulic oil tank and 1 x 85 litre backup hydraulic oil tank. Hydraulic oil filter system. Low oil level cut out. High oil temperature cut out. The control station has the following controls: A-Frame luff out and in Main wire winch in and out Guide wire winch in and out Dive Control Communications Breathing Apparatus Set DIMENSIONS: Length: 3.3m Height (Max): 4.0m Width: 2.2m Max Weight: 4.5Te DIVING BASKET: 1.2 x 1.2 x 2.2m Two man Dive basket with overhead protection frame. Cage includes diving cylinder securing ring and safety access gate. Hand holds and emergency recovery hard point. Safety lifting points welded to the top of the basket for emergency recovery. Storage space for 10 m3 onboard emergency gas in a single 50 litre 300 bar cylinder. Cylinder includes as part of the basket with 1st stage, 2 x demand valves, and 2 x open ended hoses with quarter turn isolation valves. Brass guide-wire clamps. Cage is manufactured from steel angle and tube sections and hot dipped galvanized for marine corrosion protection. BASKET WINCH: Minimum Lift Capability: Hydraulically set to 1.0 Te Maximum Lifting Speed: Controllable up to 18m per min Wire Diameter: 13mm non-rotating Wire Length: 80m Drive System: Direct hydraulic Braking: Shaft mounted non rotating multi disc internal motor brake. Hydraulic over-centre valve Automatic hydraulic band brake GUIDE WEIGHT WINCH: Minimum Lift Capability: 1.3Te Maximum Lifting Speed: Controllable up to 18m per min Wire Diameter: 10mm non-rotating Wire Length: 160m Drive System: Direct hydraulic Braking: Shaft mounted non rotating multi disc internal motor brake. Hydraulic over-centre valve Automatic hydraulic band brake For more information please contact: Offshore Diving Manager: Alan Melia +44 (0) alan.melia@gegroup.com Vertech UK Unit H1, Aberdeen Science & Energy Park Claymore Avenue, Scotland AB23 8GW Tel: +44 (0) ADDITIONAL FEATURES: An upper limit stop system is fitted to the A-Frame to act as a safety feature. The upper limit stop system is interlocked with the HPU. The Main wire and Guide wires are terminated with molded speltor sockets. Overboard flood lights are fitted to the A-Frame.

Technical Diving Equipment

Technical Diving Equipment POMMEC LARS SYSTEM EASILY CONVERTED TO WET BELL SYSTEM POMMEC 2 DIVER LAUNCH AND RECOVERY SYSTEM WITH DIVING BASKET This Launch and Recovery System is specifically designed to provide a compact option

More information

Drass. 700 Series Surface Diving System

Drass. 700 Series Surface Diving System Drass Tecnologie Sottomarine Surface Diving System The Surface Diving System is a complete range of equipment which provides the widest solution for air and gas mix diving. The trolley and A-Frame recovery

More information

Go further, go deeper

Go further, go deeper Go further, go deeper Small footprint 13X16 m Deck layout reduced on minimum 46-9 1/2 From 6 to 12 divers Easily modifiable 1 to 3 chambers can be set up 43-11 Less expensive than a DSV Mobilized in 4

More information

MODULAR SATURATION DIVING SYSTEM

MODULAR SATURATION DIVING SYSTEM MODULAR SATURATION DIVING SYSTEM The Modular Saturation system is rated to 305 MSW (1,000 ) and provides for 12-diver occupancy in two six-man twin lock chambers. The system is designed in accordance with

More information

Wet bell handling system

Wet bell handling system Wet bell Handling system Ordering information Wet bell handling system Ask for our quotation with various options The IHC Hytech Wet bell is an open wet bell handling system, that allows three divers to

More information

HRF Brochure HYPERBARIC RECEPTION FACILITY

HRF Brochure HYPERBARIC RECEPTION FACILITY HRF Brochure 200 msw / 15 Man Hyperbaric Reception Facility HYPERBARIC RECEPTION FACILITY The Hyperbaric Reception Facility has been built in accordance with American Bureau of Shipping rules and International

More information

SATURATION SYSTEM II COMPONENTS

SATURATION SYSTEM II COMPONENTS SATURATION SYSTEM II COMPONENTS SAT II is a 6-man saturation diving system designed with a two man top mate side launch bell. The system is certified to 850 fsw and is equipped with a 10-man Self-Launch

More information

SUBMARINE MANUFACTURING & PRODUCTS LTD

SUBMARINE MANUFACTURING & PRODUCTS LTD SUBMARINE MANUFACTURING & PRODUCTS LTD Worldwide Suppliers of Diving, Hyperbaric and Subsea Equipment Blackpool Road Newton Preston Lancashire PR4 3RE Telephone: +44-1772 687775 Fax: +44-1772 687774 Web

More information

Centre of Excellence for Subsea Safety

Centre of Excellence for Subsea Safety Centre of Excellence for Subsea Safety Departments nhc training nhc testing nhc consulting nhc emergency Medical Equipment Hyperbaric Welding 07 09 13 15 17 11 Welcome to nhc National Hyperbaric Centre

More information

Control Panels & Depth Gauges

Control Panels & Depth Gauges Control Panels & Depth Gauges POMMEC SCUBA REPLACEMENT SYSTEM MOBILE/PORTABLE SURFACE SUPPLIED SYSTEM (Conform IMCA D015) - Stainless steel crash proof storage frame with 4 lifting points which can hold

More information

ADCI Consensus Standards - GAP Analysis Rev. 6 and 6.1 April 2, 2014

ADCI Consensus Standards - GAP Analysis Rev. 6 and 6.1 April 2, 2014 ADCI CS Rev. 6 (2011) ADCI CS Rev. 6.1 (2014) Section 1.0 General Provisions IMPLEMENTATION OF CERTIFICATION AND EQUIPMENT REQUIREMENTS Superscripts 1- Compliance within 6 mos. 2- Compliance within 12

More information

Rules for Classification and Construction Additional Rules and Guidelines

Rules for Classification and Construction Additional Rules and Guidelines VI Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations 4 Guidelines for Equipment on Fire Fighting Ships Edition 2008 The following Guidelines come into

More information

Subsea Tooling Services Range of Dredgers

Subsea Tooling Services Range of Dredgers Subsea Tooling Services Range of Dredgers Subsea Tooling Services UK Ltd (STS) has a large selection of ROV / Diver operated dredgers. The range includes 3 4 6 8 10 and 12 dredgers. We are confident we

More information

Surface Supplied Mixed Gas Diving Operations

Surface Supplied Mixed Gas Diving Operations AB The International Marine Contractors Association Surface Supplied Mixed Gas Diving Operations www.imca-int.com IMCA D 030 Rev. 1 August 2005 AB The International Marine Contractors Association (IMCA)

More information

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E) ECS Protector PGEN-30 (PGEN-30E) Specifications For use under U.S. Patents 8,720,591, 9,144,700 and 9,186,533 Dimensions (cabinet): 24.5 (W) x 52.5 (H) x 8.5 (D) (622mm(W) x 1,334mm(H) x 216mm(D)) Dimensions

More information

Hyperbaric Testing Testing and trials for the subsea industry. jfdglobal.com

Hyperbaric Testing Testing and trials for the subsea industry. jfdglobal.com Hyperbaric Testing Testing and trials for the subsea industry jfdglobal.com About JFD Our vision is to be the unrivalled, first choice partner to commercial operators and global defence forces within the

More information

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL Capital Controls Series 71V3000 The Series 71V3000 electrically-heated vaporizer automatically vaporizes and superheats liquid chlorine, sulfur dioxide or ammonia at a rate controlled by the gas feed system.

More information

Manifolds & pressure reducing sets

Manifolds & pressure reducing sets Manifolds & pressure reducing sets Automatic Changeover Manifold (Electronic) Providing continuous supply of medical gases Pneumatech Medical Gas Solutions (PMGS) PureGAS Manifolds provide a duty or standby

More information

Crab and Lobster Live Holding System Part II (Water Pumps, Air Pumps and Pipework)

Crab and Lobster Live Holding System Part II (Water Pumps, Air Pumps and Pipework) Crab and Lobster Live Holding System Part II (Water Pumps, Air Pumps and Pipework) 1990/2/SF/AM The increased demand for crabs and lobsters, and the requirement to export live shellfish has led to the

More information

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Installation, operating and maintenance Instructions for Seemag bypass level indicator Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates

More information

Product Range. High performance and economic high pressure solutions Made in Germany

Product Range.  High performance and economic high pressure solutions Made in Germany Product Range Purification Storage Filling Panels Nitrox/Trimix High performance and economic high pressure solutions Made in Germany www.lw-compressors.com 2 Lenhardt & Wagner Solid Growth Lenhardt &

More information

Saab Seaeye Cougar XT Compact

Saab Seaeye Cougar XT Compact The Seaeye Cougar-XT Compact is a highly flexible and extremely powerful electric ROV with working depths of 300 metres. This system comes with almost all of the specifications of the very reliable Couger-XT

More information

TECHNICAL SPECIFICATION SCHILLING UHD III WORK CLASS ROV SYSTEM

TECHNICAL SPECIFICATION SCHILLING UHD III WORK CLASS ROV SYSTEM TECHNICAL SPECIFICATION SCHILLING UHD III WORK CLASS ROV ROVOP, Silvertrees Drive, Westhill, Aberdeen AB32 6BH, Scotland, UK T +44 (0) 1224 472565 E rov@rovop.com www.rovop.com TECHNICAL SPECIFICATION

More information

Manual Actuated Boiler Blowdown Valves

Manual Actuated Boiler Blowdown Valves Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety

More information

Instrumentation Catalogue

Instrumentation Catalogue Hydraulic & Offshore Supplies Instrumentation Catalogue YOUR GATEWAY TO GLOBAL SUPPLY HOSE ASSEMBLIES PRESSURE TESTING WALFORM EQUIPMENT PACKAGES FLANGES PIPE & TUBE Hydraulic & Of f shore Supplies Specialist

More information

Subsea Tooling Services Range of Dredgers

Subsea Tooling Services Range of Dredgers Subsea Tooling Services Range of Dredgers (STS) has a large selection of ROV / Diver operated dredgers. The range includes 3 4 6 8 10 and 12 dredgers. We are confident we have a dredger that will suit

More information

Document Title : Air Diving Procedures Manual. Asia Divers Limited. Air Diving Procedures Manual DIV-MA Copyright

Document Title : Air Diving Procedures Manual. Asia Divers Limited. Air Diving Procedures Manual DIV-MA Copyright Asia Divers Limited Document Title : Air Diving Procedures Manual Doc. No : DIV-MA-0002 Page : 1 of 43 Rev : 0 Date : 06 th July 2001 Asia Divers Limited Air Diving Procedures Manual DIV-MA-0002 Copyright

More information

Spirax Compact FREME Flash Recovery Energy Management Equipment

Spirax Compact FREME Flash Recovery Energy Management Equipment IM-UK-cFREME UK Issue 1 Spirax Compact FREME Flash Recovery Energy Management Equipment Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4.

More information

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Standard Operating and Maintenance Instructions for Pumping System Model PS-90 Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075

More information

MEDICAL EQUIPMENT CATALOG

MEDICAL EQUIPMENT CATALOG THE MOST TRUSTED MEDICAL EQUIPMENT IN NORTH AMERICA MEDICAL EQUIPMENT CATALOG Total Components Including Bulk Oxygen Supply, Back up and Delivery Equipment Designs for High Pressure, Liquid or Bulk Applications

More information

Reclaim Basic Set Up

Reclaim Basic Set Up This purpose of the document is to simplify the set up and understand the Gas Services reclaim system functions. The Gas Services Reclaim Manual is to be used for reference, maintenance, and servicing.

More information

Common Discrepancies Uncovered on ADCI Diving Contractor & Training Program Audits

Common Discrepancies Uncovered on ADCI Diving Contractor & Training Program Audits Common Discrepancies Uncovered on ADCI Diving Contractor & Training Program Audits Ways to Set Your Company or School Up For Success on ADCI Audits and Reduce Costs In most instances, all discrepancies

More information

take a deep breath... Dependable high quality breathing air compressors

take a deep breath... Dependable high quality breathing air compressors take a deep breath... Dependable high quality breathing air compressors IN THE LEAGUE OF ITS OWN... SEACOMAIR manufacture a dependable high quality breathing air compressors, designed for continuous duty

More information

THE COMPACT LINE. Mobile power packs in convincing BAUER quality l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED

THE COMPACT LINE. Mobile power packs in convincing BAUER quality l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED THE COMPACT LINE Mobile power packs in convincing BAUER quality 100 140 l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED COMPACT LINE mobile breathing air compressors for high demands Due to its legendary

More information

System Pressure Manager Standard & System Pressure Manager Plus

System Pressure Manager Standard & System Pressure Manager Plus System Pressure Manager Standard & System Pressure Manager Plus Installation, Commissioning & Servicing Instructions Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,

More information

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times Tseries Series AB AB Air Air Boosters Boosters The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times.01/1 MANIFOLD MOUNTED VALVES FOR EASY SERVICING

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

All information correct as of 25 th September 2013 and subject to change without notice. 6 inch HURRICANE modular dredge equipment operations manual.

All information correct as of 25 th September 2013 and subject to change without notice. 6 inch HURRICANE modular dredge equipment operations manual. All information correct as of 25 th September 2013 and subject to change without notice 6 inch HURRICANE modular dredge equipment operations manual. Introduction. Hurricane 6 inch modular dredge. The HURRICANE

More information

CNG FILLING STATIONS

CNG FILLING STATIONS CNG FILLING STATIONS GAS INLET 3/4 F EXIT CNG TO CAR TANK 5 mt / 16 feet HOSE AND FILLING NOZZLE REMOTE ELECTRIC PANEL THREE-PHASE height 40 cm / 15.7 width 30 cm / 11.8 depth 20 cm / 7.8 EQUIPPED WITH

More information

Air Amplifiers & SYSTEMS

Air Amplifiers & SYSTEMS Air Amplifiers & SYSTEMS We Accept VISA, MasterCard and American Express Air Amplifiers Point-of-Use Air Solutions Maximator air amplifiers are designed to boost plant air pressure or increase the supply

More information

ULMATEC LAUNCH AND RECOVERY SYSTEMS

ULMATEC LAUNCH AND RECOVERY SYSTEMS M L U NC LAU MS ERY V ECO DR N HA C E AT TE SYS S R LA ULMATEC LAUNCH AND RECOVERY SYSTEMS Ulmatec develops efficient, safe and robust solutions for handling remotely operated vehicles (ROVs) from ships

More information

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL SF SERIES CNG COMPRESSOR MODEL HF-4MH 4 Nm3/Hour Displacement OPERATION MANUAL 1 Content 1. General Description...3 2. Main technical parameters...3 3. Structural principle...4 3.1Main structure...4 3.2Compressor

More information

VETROSON. OXY-GEN SYSTEMS (Oxygen Generating Systems) Question & Answer Brochure

VETROSON. OXY-GEN SYSTEMS (Oxygen Generating Systems) Question & Answer Brochure VETROSON OXY-GEN SYSTEMS (Oxygen Generating Systems) Question & Answer Brochure Q & A VETROSON OXY-GEN SYSTEMS 1) Q. How does the VETROSON OXY-GEN System work? A: A simplified explanation is that air (21%

More information

NOAA DIVING PROGRAM MINIMUM STANDARD FOR DECOMPRESSION DIVING USING OPEN-CIRCUIT SCUBA EQUIPMENT

NOAA DIVING PROGRAM MINIMUM STANDARD FOR DECOMPRESSION DIVING USING OPEN-CIRCUIT SCUBA EQUIPMENT NOAA DIVING PROGRAM MINIMUM STANDARD FOR DECOMPRESSION DIVING USING OPEN-CIRCUIT SCUBA EQUIPMENT NOAA Diving Center 7600 Sand Point Way, N.E. Seattle, WA 98115-0070 NOAA DIVING PROGRAM MINIMUM STANDARD

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure

More information

UNDERGROUND REFUGE REFUGE CHAMBERS 2017

UNDERGROUND REFUGE REFUGE CHAMBERS 2017 UNDERGROUND REFUGE REFUGE CHAMBERS 2017 BOST REFUGE CHAMBERS BUILT BY MINERS, FOR MINERS Bost Group is one of the leading manufacturers of Equipment for the Underground Mining Operations across the Globe.

More information

South-Tek Systems - Nitrogen Generation Corrosion Inhibiting System. Designed for: Dry or Preaction Fire Protection Systems (FPS)

South-Tek Systems - Nitrogen Generation Corrosion Inhibiting System. Designed for: Dry or Preaction Fire Protection Systems (FPS) South-Tek Systems - Nitrogen Generation Corrosion Inhibiting System Designed for: Dry or Preaction Fire Protection Systems (FPS) 1.0 Description of Work 1.1 The Fire Sprinkler Contractor shall provide

More information

CHE Well Testing Package/Service:

CHE Well Testing Package/Service: CHE Well Testing Package/Service: CHE delivers well testing package And services, trailer mounted well testing package and offshore/onshore well testing services with over 10 years experience. Our testing

More information

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward GN 4-7 kw/5.5-10 hp Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward Total capability, total responsibility Right at the heart of your business, Atlas Copco delivers quality compressed air

More information

1. PARTS INTRODUCTION ELECTRICAL NOTES INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10.

1. PARTS INTRODUCTION ELECTRICAL NOTES INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10. CONTENTS 1. PARTS 3. 2. INTRODUCTION 4. 3. ELECTRICAL NOTES 5. 4. INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10. 8. ELECTRICAL CONNECTIONS 10/11. 9. SPECIFICATIONS

More information

The number of test stands can be adapted to the special requirements.

The number of test stands can be adapted to the special requirements. Model DPC Model DPC 01 Simultaneous testing of several cylinders and cartridges is possible. For repeated pressure testing of CO2 high-pressure and breathing air cylinders. The number of test stands can

More information

Check with local zoning official for property line distance requirements.

Check with local zoning official for property line distance requirements. RESIDENTIAL POOL PLAN SUBMITTAL GUIDELINES The following guidelines are intended to assist municipal residents with the permit acquisition process with regard to pools, spas and hot tubs for single family

More information

STOP. Chapter 1 General Information KMDSI Products. 1.1 Introduction. EXO Full-Face Mask Manual

STOP. Chapter 1 General Information KMDSI Products. 1.1 Introduction. EXO Full-Face Mask Manual Chapter 1 General Information KMDSI Products EXO Full-Face Mask Manual STOP This manual will refer to location numbers in specific drawings, or in the exploded view, which is in the back of this manual.

More information

GENO -Flushing Compressor Product Data Sheet F 02

GENO -Flushing Compressor Product Data Sheet F 02 GENO -flushing compressor 1988 K Fig. 1: GENO -flushing compressor 1988 K Designated application is suitable for the following fields of application: Flushing of pipes with water/air mix prior to the start-up

More information

Budget Range Operators Handbook

Budget Range Operators Handbook Budget Range Operators Handbook BAMBI AIR COMPRESSORS LTD 152 Thimble Mill Lane Heartlands Birmingham B7 5HT United Kingdom Tel: 0121 322 2299 Fax: 0121 322 2297 Email: sales@bambi-air.co.uk www.bambi-air.co.uk

More information

Setup Guide for your HVO Naked Drone

Setup Guide for your HVO Naked Drone Setup Guide for your HVO 60 + 60 Naked Drone 1 The Big Picture 1. Choose The System Location 2. Get the Power Ready 3. Get an Approved Oxygen Regulator 4. Get the Tools You ll Need 5. Unpack the crate

More information

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES PROCESS ANALYSERS DF-550E The DF-550E Nano Trace oxygen analyser is a Coulometric sensor based analyser designed to measure oxygen as a contaminant at ultra trace levels in ultra high purity electronic

More information

Chapter 1 General Information KMDSI Products

Chapter 1 General Information KMDSI Products STOP! BEFORE GOING FURTHER- SuperLite 17B This manual will refer to location numbers in specific drawings, or in the exploded view, which is in the back of this manual. These numbers are called location

More information

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection 1170850/1 IM-P117-36 ST Issue 1 MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection Installation and Maintenance Instructions 1. Safety information 2. General product information

More information

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer Inflatable Packer Single & Double Single & Double Packer Dimension Wireline Packer Water Testing Packer (WTP) Packer Packer Working Pressure & Depth Chart Packer Water Hand Pump Packer Air Driven Pump

More information

ISE Subsea Tools and Toolsleds

ISE Subsea Tools and Toolsleds 1734 Broadway St. Port Coquitlam, B.C. V3C 2M8, Canada +1.604.942.5223 +1.604.942.7577 info@ise.bc.ca www.ise.bc.ca ISE Subsea Tools and Toolsleds 1 INTRODUCTION The value of an ROV is increased by its

More information

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This

More information

Product Range. Compressors Purification Storage Filling Panels Nitrox/Trimix. High Pressure Solutions from L&W!

Product Range. Compressors Purification Storage Filling Panels Nitrox/Trimix. High Pressure Solutions from L&W! Product Range Purification Storage Filling Panels Nitrox/Trimix High Pressure Solutions from L&W! 2 Lenhardt & Wagner Solid Growth Lenhardt & Wagner is one of the leading and renowed companies in the market

More information

Active Hydrophore System AHS-01

Active Hydrophore System AHS-01 BRIEF PRODUCT DESCRIPTION: Standard material Seawater exposed parts: Titanium gr. 2 Rapid Response Valves: Titanium gr. 2 Cabinet: SST AISI 316 This is a skid mounted unit, with the hydrophore tank and

More information

All technical data may be changed MADE IN ITALY BY NARDI COMPRESSORI

All technical data may be changed MADE IN ITALY BY NARDI COMPRESSORI PACIFIC MX NITROX BREATHING AIR according to DIN EN 12021 MAX OXYGEN 40% DELIVERY l/min 600 m 3 h 36 PRESSURE BAR 225 PSI 3250 Quality system certified to iso 9001 BREATHING AIR is a product line that

More information

V-Major, V-Compact. Reciprocating Compressors. Intelligent Air Technology

V-Major, V-Compact. Reciprocating Compressors. Intelligent Air Technology V-Major, V-Compact Reciprocating Compressors Intelligent Air Technology & Significant Energy Savings with Lower Running Costs Efficient. LOW POWER CONSUMPTION 75% of the running cost of an air compressor

More information

TotalPac X Single interlock Preaction system Electric release

TotalPac X Single interlock Preaction system Electric release DESCRIPTION This TOTALPAC X integrated fire protection system by FireFlex Systems Inc. consists of a preaction system trim totally preassembled, pre-wired and factory tested. All electrical and mechanical

More information

All information correct as of 29 nd August 2013 and subject to change without notice CORRECT AS OF

All information correct as of 29 nd August 2013 and subject to change without notice CORRECT AS OF All information correct as of 29 nd August 2013 and subject to change without notice 1 CORRECT AS OF 21-11-13 Liquid and gas sampling tool introduction. Safety has been given paramount consideration with

More information

Flamco Flamco-Fill STA Flamco-Fill STM

Flamco Flamco-Fill STA Flamco-Fill STM STA STM Typ STA 5936 Typ STM 5937 GB Installation and operating instructions 1999, 2 Contents GB UK Limited P.O. Box 9, Washway Lane, St. Helens, Merseyside WA10 6FE United Kingdom Telephone: 01744 744744

More information

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems Name of Property: Address: Phone Number: Inspector: Contract No.: Date: This Report Covers: Monthly Quarterly Annual Other

More information

High Pressure Breathing Air Compressors

High Pressure Breathing Air Compressors High Pressure Breathing Air Compressors [ Full variety for different applications] MSA offers a comprehensive range of high pressure breathing air compressors for both the firefighting and diving market,

More information

Chapter 1 General Information KMDSI Products

Chapter 1 General Information KMDSI Products Kirby Morgan 37SS Chapter 1 - Introduction This manual will refer to location numbers in specific drawings, or in the exploded view, which is in the back of this manual. These numbers are called location

More information

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions. Oxford Instruments Plasma Technology www.oxford-instruments.com About this data sheet This data sheet provides basic information about the installation of a tool. Floor and wall loadings Table 1 lists

More information

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI hydro-pac, inc. LX-SERIES Low-Pressure Gas Compressors 1500 to 6000 PSI hydro-pac, inc. LX-SERIES Features Hydro-Pac LX-SERIES Gas Compressors feature: Oil-free non lubricated gas pistons and cylinders

More information

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION OCT2010 STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 020 87833050

More information

7. TDI Advanced Wreck Diver Course

7. TDI Advanced Wreck Diver Course 7. TDI Advanced Wreck Diver Course 7.1 Introduction This course provides training and experience to competently conduct advanced wreck dives. This program includes penetration skills and techniques. Depths

More information

NAUTILUS Small pump. Powerful performance. Certified according to DIN 14425, submersible pumps for fire departments

NAUTILUS Small pump. Powerful performance. Certified according to DIN 14425, submersible pumps for fire departments NAUTILUS Small pump. Powerful performance. Certified according to DIN 14425, submersible pumps for fire departments The first choice for high water and flooding. Rosenbauer NAUTILUS submersible pump NAUTILUS.

More information

PSI France DESCRIPTION Mise à Jour : 02/09/02 SMAL202 Version : 0 Page 1 sur 9

PSI France DESCRIPTION Mise à Jour : 02/09/02 SMAL202 Version : 0 Page 1 sur 9 SMAL202 Version : 0 Page 1 sur 9 1. SUMMARY SPECIFICATIONS...2 2. PERSONNEL COMPARTMENT...3 3. BATTERY...4 4. 120V DISTRIBUTION...4 5. 24V DISTRIBUTION...5 6. THRUSTERS...5 7. PROJECTORS...5 8. AIR DISTRIBUTION...5

More information

IMCA Competence Assessment Portfolio April 2016

IMCA Competence Assessment Portfolio April 2016 Self- Checklist Entry Level Criteria Acceptance Criteria Attained Completed diver training to IMCA-recognised air diver qualification Passed medical examination for fitness to dive Passed offshore survival

More information

SEMI-SUB AND JACK UP DRILL RIGS SPECIALIST CLEANING SERVICES & EQUIPMENT RENTAL SOLUTIONS

SEMI-SUB AND JACK UP DRILL RIGS SPECIALIST CLEANING SERVICES & EQUIPMENT RENTAL SOLUTIONS SEMI-SUB AND JACK UP DRILL RIGS SPECIALIST CLEANING SERVICES & EQUIPMENT RENTAL SOLUTIONS PONTOON BALLAST / FUEL TANKS DRILL WATER TANKS POTABLE WATER TANKS SPECIALIST CLEANING FUEL OIL DAY TANK & SETTLING

More information

In Vessel Composter Installation & Commissioning Manual

In Vessel Composter Installation & Commissioning Manual In Vessel Composter Installation & Commissioning Manual Contents Customer responsibilities Transportation Lifting Delivery Pre-installation requirements Installation Drainage Ventilation Levelling Unpacking

More information

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

GM Series Dual-Block Multi-Function Gas Control Valves

GM Series Dual-Block Multi-Function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series

More information

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

Multiple Pressure Booster Systems With Variable Speed Controller Type BL Multiple Pressure Booster Systems With Variable Speed Controller Type BL General Characteristics - Single or multistage pumps - Horizontal or vertical mounting - Total head 30m ~ 250m - Material construction:

More information

Hydro Bond Engineering Ltd Electrical Penetrators: Manned and Unmanned Systems HPS (Hydro Bond Penetrator Series)

Hydro Bond Engineering Ltd Electrical Penetrators: Manned and Unmanned Systems HPS (Hydro Bond Penetrator Series) Hydro Bond Engineering Ltd Electrical Penetrators: sales@hydrogroup.uk www.hydrogroupcom tel: +44 (0)1224 822996 fax: +44 (0)1224 825142. sales@hydrogroup.uk www.hydrogroup-asia.com tel: +65 63343566 fax:

More information

Swimming Pools, Hot Tubs and Spas

Swimming Pools, Hot Tubs and Spas OLATHE FIRE DEPARTMENT BUILDING CODES 1225 S. Hamilton Circle Olathe, KS 66061 / Main: (913) 971-7900 / Fax: (913) 971-9812 Swimming Pools, Hot Tubs and Spas Definitions: Swimming Pool- Any structure intended

More information

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor) 1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor) 1. According to NFPA 99, SCFM is an acronym for. a) Surface Conditions at Fahrenheit Mercury b) Standard Conditions

More information

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0) Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk SOFTLINE CUTTER SL80 PRODUCT CODE No. 980248 INSTRUCTIONS FOR INSTALLATION,

More information

Introduction and background

Introduction and background Introduction and background Commercial diving typically refers to professional divers who have completed specialized commercial diving training programs and who utilize diving equipment better suited to

More information

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100 Information Sheet PlasmaPro Estrelas100 About this information sheet This data sheet provides basic information about the installation of a PlasmaPro Estrelas100 tool. Some of the information in this sheet

More information

RESOLUTION A.855(20) adopted on 27 November 1997 STANDARDS FOR ON-BOARD HELICOPTER FACILITIES

RESOLUTION A.855(20) adopted on 27 November 1997 STANDARDS FOR ON-BOARD HELICOPTER FACILITIES A 20/Res.855 17 December 1997 Original: ENGLISH ASSEMBLY 20th session Agenda item 9 RESOLUTION A.855(20) adopted on 27 November 1997 THE ASSEMBLY, STANDARDS FOR ON-BOARD HELICOPTER FACILITIES RECALLING

More information

Evaporator (DX) Freon Applications 1 12 Tons MHF

Evaporator (DX) Freon Applications 1 12 Tons MHF Evaporator (DX) Freon Applications 1 12 Tons > > Used For small to medium freon applications The Global Leader In Heat Exchange Technology With seven decades of experience and commitment to total client

More information

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200 Specification Bulletin (rev.01) Series CH4200 Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200 Easy, fast& accurate digital with 11 points calibration Laser sensor offering actual feed

More information

Horizontal Bladder Tanks

Horizontal Bladder Tanks DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Workhorse 8 Oxygen System Model No 5665, 5673, 5679

Workhorse 8 Oxygen System Model No 5665, 5673, 5679 11436 Sorrento Valley Road, San Diego CA 92121 USA 858-558-0202 Fax 858-558-1915 Workhorse 8 Oxygen System Model No 5665, 5673, 5679 Part Number 1815 Revision B SeQual Technologies San Diego, CA USA Cautions,

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 9 ACCUMULATORS The material needed for outcome 2 is very extensive so there are

More information

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L Calibration Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L WIKA data sheet CT 91.05 for further approvals see page 2 Applications Calibration service companies and service industry Calibrations

More information

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring. Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions

More information

Safety Selector Valves Dual Pressure Relief Device System

Safety Selector Valves Dual Pressure Relief Device System ANDERSON GREENWOOD Features and enefits Provides a safe, efficient method of switching from an active pressure relief device to a standby, maintaining system overpressure protection regardless of Safety

More information