20 to 280l/min 21MPa. econnecting a remote control valve to the vent port allows remote control of adjustment pressure.

Size: px
Start display at page:

Download "20 to 280l/min 21MPa. econnecting a remote control valve to the vent port allows remote control of adjustment pressure."

Transcription

1 Pressure Reducing (and heck) Valve eatures PRSSUR RU ( ) VV to 8l/min Pa -***-*- R -***-*- Specifications qthis valve is used when part of the circuit uses pressure that is lower than the main circuit. wven when pressure changes in the primary main circuit, the reduced secondary pressure is adjusted automatically and maintained at a constant level. eonnecting a remote control valve to the vent port allows remote control of adjustment pressure. rthe mounting surface of the gasket conforms to the S standards shown in the table below. R Pressure ontrol Valve odel o. ominal aximum Working aximum Pressure adjustment range Weight kg iameter Pressure low Rate Screw ounting asket ounting (Size) Pa{kgf/cm } l/min Pa{kgf/cm } T Type Type () -T-- - () -T-- - () -T-- - () -T-- - () () () () Weight values in parentheses are for when a check valve is included. The cracking pressure of the check valve is.pa{.kgf/cm } () T Reducing valve esign number Pressure adjustment ranges,,, ominal diameter (size) ounting method T: Screw ounting : asket ounting Reducing and check valve nstallation imension rawings /8 xplanation of model o. -T**-*- (Screw ounting) odel o. -T-* T-* T-* odel o. P -T-* /8 -T-* /4 -T-* ¼ X Rc P 4 - /8 {4} 5,, /4 Vent Port ¼ 8.5 to {. to.}. to.5 {. to 5.5} to 7 { 8. to 7.4}.5 to {5.7 to 4 } to 7 { 8. to 7.4}.5 to {5.7 to 4 } to 7 { 8. to 7.4}.5 to {5.7 to 4 } (hangeable to two other directions) (Primary pressure) (Secondary pressure). (.). (.) 5.7 (.). (.) andling z Provide an independent drain pipe directly to the tank. x When using a remote control valve, connect piping to the reducing valve vent port. Pipe capacity can be a source of vibration. Use of thick iron pipe with an inside diameter of no more than 4mm and a connection length of no more than three meters is recommended. c Use the following table for specification when a sub plate is required. odel o. -- /8 -X- /. () --*- -- /4 -X-.9 () --*- -- ¼ -X- ½.7 () --*- These sub plates can also be used for pressure control valves. v The following are the bundled mounting bolts. odel o..9 (4.).9 (4.). (.).8 (.) Pipe Weight iameter kg olt imensions () --*- 75l 4 () --*- 85l 4 () --*- 5l asket Surface imensions S S S pplicable Pump odel Q'ty Tightening Torque m{kgf cm} 45 to 55 {4 to 5} ote) or mounting bolts, use bolts of.9 strength classification or equivalent. -8 ote) fter the orientation of the pressure adjusting handle has been changed, also modify the cover alignment surface -ring (R-9 P).

2 -**-*- (asket ounting) X Vent connection port P rom back - 7.5x counterbore holes (Primary pressure) (Secondary pressure) -T**-*- (Screw ounting) odel o. --* * * ote) The orientation of the pressure adjusting handle cannot be change. (hangeable to one other direction) Pressure ontrol Valve X Rc P P (Primary pressure) (Secondary pressure) - P odel o. P -T-* /8 -T-* /4 -T-* ¼ ote) fter the orientation of the pressure adjusting handle has been changed, also modify the cover alignment surface -ring (R-9 P). -9

3 -**-*- (asket ounting) X P rom back 4-7.5x counterbore holes Pressure ontrol Valve (Primary pressure) (Secondary pressure) Sub Plate -***- odel o. --* * * ote) The orientation of the pressure adjusting handle cannot be change. R PP QQ 4-7.5x counterbore holes 7 depth 8 - VV RR SS TT Piping and plug not required UU- tap - 4 XX WW - Rc YY - odel o. PP QQ RR SS TT UU VV WW XX YY -- / X- / -- / X- -- ¼ X- ½ -

4 Performance urves ydraulic perating luid inematic Viscosity mm /s haracteristics () --*- () --*- Pressure rain low Rate haracteristics () -***-*- Pa{kgf/cm } Path. Path.4 (main valve open). Path (main valve closed). {.} {4.} {.} {.} { 8.} {.} { 4.} Pa {kgf/cm }..4.. Path Path (main valve open) Path (main valve closed) {.} {4.} {.} {.} { 8.} {.} { 4.} cm /min rain flow rate 5 5 ()-*-*- ()-*-*- ()-*-*- 4 ()-* {.}. {.} (, Type) {5} {} {5} {4} (, Type) {5.} {.} {5.} {} {5.5} ifferential pressure (Pa) {kgf/cm } Pa {kgf/cm } () --*- Path Path (main valve open).7 Path (main valve closed).5.. {.} {8.} {7.} {.} {5.} {4.} {.} {.} Pa{kgf/cm } Secondary Pressure low Rate haracteristics () -T-*- () -*- - Path Path (main valve open).7 Path (main valve closed) {8.} {7.} {.} {5.} {4.} {.} {.} {.} Pa {kgf/cm } Pressure.5. {.} {5.} {4.}. {.}. {.} {.} Pressure ontrol Valve () --*- () -T-*- Pa{kgf/cm } Path Path (main valve open).7 Path (main valve closed).5... {8.} {7.} {.} {5.} {4.} {.} {.} {.} Pa{kgf/cm } Path. Path (main valve open).4 Path (main valve closed)... {.} {4.} {.} {.} { 8.} {.} { 4.} {.}

5 ross-sectional rawings () -** Pressure ontrol Valve --**-* Part o. Part ame ody over over 4 Piston 5 Spring andle 7 ut 8 Retainer 9 Spring pin Push rod Spring Poppet Seat 4 ollar 5 Poppet Spring 7 Spring guide 8 Screw 9 Plug Plug -ring -ring -ring 4 -ring 5 -ring -ring 7 ameplate ote) Part numbers 5,, 7, and 5 are not required when there is no check valve. Seal Part ist (it odel umber RS-***()) Part o. Part ame Type/Part umber --*- -T-*- --*- -T-*- --*- -T-*- Q'ty -ring R-9 P R-9 P R-9 R-9 R-9 4 R-9 4 -ring R-9 P R-9 P R-9 5 -ring R-9 P R-9 P R-9 P 4 -ring R-7- P R-7- P R-7- P R-7- P R-7- P R-7- P 5 -ring R-9 P R-9 P R-9 P4 R-9 P4 R-9 P R-9 P -ring R-9 P R-9 P R-9 P R-9 P R-9 P R-9 P 4 ote) The materials and hardness of the -ring conforms with S 4. *** in the kit number is used for specification of the valve size (, T, etc.) To specify inclusion of a check valve, add to the end. -

Pressure Control (and Check) Valve

Pressure Control (and Check) Valve Pressure ontrol (and heck) Valve PRSSUR OTRO (A ) VAV 50 to 80l/min 4Pa eatures qthis circuit control valve works as a sequence valve, unloading valve, and counter balance valve. waximum operating pressure

More information

Electro-hydraulic Proportional Flow and Direction Control Valve

Electro-hydraulic Proportional Flow and Direction Control Valve lectro-hydraulic control valve his valve uses a D solenoid in a traditional 4- way solenoid valve to create a solenoid valve capable of both direction switching and highspeed control. he lineup consists

More information

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics. Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum

More information

E SERIES. Specification. E Series. Relief and Flow Control Valves O M O M EIC-H Model No. Description

E SERIES. Specification. E Series. Relief and Flow Control Valves O M O M EIC-H Model No. Description 4 Ω-1 Ω Series Proportional Electro-ydraulic This relief and flow control valve is an energy-saving valve that supplies the minimum pressure and flow necessary for actuator drive. Since this valve controls

More information

Digital relief valves D-CG

Digital relief valves D-CG Digital relief valves D-G unctional Symbols D-G- Specifications Size Maximum working pressure Rated flow Maximum flow Maximum adjustable pressure Ma Minimum control pressure Hysteresis Repeatability emperature

More information

Digital directional & flow control valves D-DF(R)G

Digital directional & flow control valves D-DF(R)G Digital directional & flow control valves D-DF(R)G Functional Symbols Model Code D-DFG- D-DFG-~ D-DFRG-/ D-DFG--C--- Digital directional & flow control valve Size Spool type (neutral position) : ll ports

More information

IN-LINE CHECK VALVES CIT-02 / 03 / 06 / 10 (1/4,3/8,3/4,1-1/4) RIGHT ANGLE CHECK VALVES CRT / CRG-03 / 06 / 10 (3/8,3/4,1-1/4)

IN-LINE CHECK VALVES CIT-02 / 03 / 06 / 10 (1/4,3/8,3/4,1-1/4) RIGHT ANGLE CHECK VALVES CRT / CRG-03 / 06 / 10 (3/8,3/4,1-1/4) IN-LIN HK VLVS IT- / 3 / / (/,3/8,3/,-/) RIGHT NGL HK VLVS RT / RG-3 / / (3/8,3/,-/) Up to 5 MPa (33 PSI), 3 L/min (33 U.S.GPM) Pub. - IRTIONL ONTROLS These valves allow free flow in one direction and

More information

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting REDUING (ND HEK) VLVES RT/RG RT/RG -3// (3/8, 3/, -/) Threaded onnections / Mounting Up to MPa (5 PSI), 5 L /m in (3 U.S.GPM) Pub. E-3 Pressure Reducing Valves Pressure reducing valves are used to set

More information

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10 / ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications

More information

Min. Metered Flow Capacity L/min. Max. Oper. Pressure Kgf/cm (0.04)* F- FC G N -11 H01. Max. Metered Flow Capacity L/min.

Min. Metered Flow Capacity L/min. Max. Oper. Pressure Kgf/cm (0.04)* F- FC G N -11 H01. Max. Metered Flow Capacity L/min. Flow Control These are pressure and temperature compensating type valves and maintain a constant flow rate independent of change in system pressure (load) and temperature (Viscosity of the fluid). They

More information

Regulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount)

Regulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount) eries R 2- ow to Order opper, fluorine and silicon-free + Low particle generation il hread type Rc 0 R 03 2 R 03 ody size / ith bracket Round pressure ith set nut tandard specifications odel luid roof

More information

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the

More information

Filter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size.

Filter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size. eries ow to Order opper, fluorine and silicon-free + Low particle generation il ote 1) ote 2) part no. lean series hread type Rc racket assembly ote ) ote 9) 1.0a 0.2a / -20 49-01 49-2-01 ilter regulator

More information

Axial piston pumps type PVC

Axial piston pumps type PVC www.atos.com Table TA16-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low noise

More information

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM Catalog HY14-252/US Introduction Series C, CPO, F, PRD, PR, R anapak valves provide a variety of check, flow control, pressure relief and pressure reducing functions in a compact NFPA D3, D5 and D8 sandwich

More information

Axial piston pumps type PVC

Axial piston pumps type PVC www.atos.com Table TA16SK-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low

More information

EXH. Specifications. Descriptions. Min. working pressure MPa

EXH. Specifications. Descriptions. Min. working pressure MPa Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,

More information

RP series Rotor Pumps

RP series Rotor Pumps ontact etails RP series Rotor Pumps Nomenclature Features Low noise Substantial reduction of the operation noise, by to db (comparison with aikin products), and improved sound quality are achieved by adopting

More information

Smooth Vent Valve XVD. Series

Smooth Vent Valve XVD. Series Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the

More information

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm) Vickers artridge Valves Logic Elements Screw-in artridge Valves Pressures to 9 bar ( psi) Flows to l/min (8 USgpm) Revised 9/98 7 ontents MODEL DESRIPTION TYPIL PPLITION PRESSURE bar (psi) RTED FLOW l/min

More information

Smooth Vent Valve. XVD Series

Smooth Vent Valve. XVD Series Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the

More information

Series variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 )

Series variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 ) Series variation High damping effect and types of materials Model / appearance Metering valve with silencer Model no. SMW-6 SMW-8 FMS-M SMW- SMW- (R) M M /8 / /8 / / / / 6 8 Effective sectional area (mm

More information

Reservoir End Covers Type EC

Reservoir End Covers Type EC Other Reservoir ccessories imensions / Technical ata / Order odes Reservoir End overs Type E H Ø2 Ø1 7 Gauge Steel haracteristics Materials End cover made of 7 Grade Steel (pickled and oiled); Stainless

More information

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0 ir line equipment P1H, PTH Filter/Regulator- Lubricator Combination Units 07 Series Compact design Filter removes liquids and solid particles down to 5 µm Push to lock adjusting knob with tamper resistant

More information

Model AWG20 AWG30 AWG40 AWG20K AWG30K AWG40K

Model AWG20 AWG30 AWG40 AWG20K AWG30K AWG40K Modular Type ilter Regulator with uilt-in Pressure auge eries W ilter Regulator with uilt-in Pressure auge eries W ominal filtration rating ccessory W2 /8, /4 W3 /4, 3/8 W /4, 3/8, /2 racket Pages 424

More information

Pneumatic Function Fittings Metric & Inch

Pneumatic Function Fittings Metric & Inch Metric & nch Sensor Fitting Very compact units asy tube insertion for rapid assembly of pneumatic circuits Positive tube anchorage Simpler pneumatic systems liminates need for electrical reed switches

More information

Filter Regulator 21 AW 30 K F 03 BG JN. Description. Without backflow function. Rc NPT 1/8 1/4 3/8 1/2 3/4

Filter Regulator 21 AW 30 K F 03 BG JN. Description. Without backflow function. Rc NPT 1/8 1/4 3/8 1/2 3/4 eries eries ilter Regulator ilter Regulator with ackflow unction ow to Order lean series opper, fluorine and silicon-free low particle generation ilter regulator 10 03 21 03 q w e r t y "" must always

More information

Leak free Pipe Rupture Valve for Excavators

Leak free Pipe Rupture Valve for Excavators Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................

More information

Pilot Operated Check Valves

Pilot Operated Check Valves Pilot Operated Check Valves These check valves allow flow in one direction and prevent flow in the reverse direction, until operated by pilot pressure to allow free reverse flow. The specified cracking

More information

ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9 uto Feed Lube, uto Feed Tank LF00 to 900, -/-9 Standard Specifications uto feed lube uto feed tank LF00 LF00-0 LF00 LF00 LF00 LF900 - --IS- -9 IR : OIL : Fluid Proof pressure ir. MPa 0. MPa.0 MPa (Note

More information

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic

More information

Electrically Operated Pressure-Relief Cartridge, Size 10

Electrically Operated Pressure-Relief Cartridge, Size 10 Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description

More information

Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Dump Valve Service Kit for Series 2300 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit

More information

Industrial Regulator Series 1800/2000

Industrial Regulator Series 1800/2000 E S 85. Industrial Regulator Series / M Quality System QMI is ccredited by: R E I T ISO 9 ertified R E NSI R G I S T R R utch ouncil for ccreditation Measurement Engineers Since 86 merican Meter Series

More information

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Power Valve: Precision Regulator. High precision, large capacity relief regulator Power Valve: Precision Regulator Series VEX High precision, large capacity relief regulator port large exhaust capacity pressure reducing valve which utilizes a nozzle flapper mechanism available as air

More information

Sandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve

Sandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve Technical Information Series PRM General Description Series PRM reducing valves are used to regulate pressure, in one area of a circuit, below normal system pressure. This style valve is well suited to

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION 2/2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32 Size 32 up to 42 MPa 700 dm 3 /min WK 490 907 04.1999r. 2/2 way cartridge valve type URZS 32 can be used to build hydraulic systems

More information

Bulletin 2533-M3/USA Service Bulletin. Series PR25MA, PR25P, PR25S, PR32P, PR32S. Effective: July 1, Pilot Operated Pressure Reducing Valves

Bulletin 2533-M3/USA Service Bulletin. Series PR25MA, PR25P, PR25S, PR32P, PR32S. Effective: July 1, Pilot Operated Pressure Reducing Valves Service Bulletin Series PR25MA, PR25P, PR25S, PR32P, PR32S Effective: July 1, 1995 Pilot Operated Pressure Reducing Valves WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS

More information

Thin pressure gauge. G401-W Series. Symbol Descriptions. A Connection A A. B Pressure display [MPa] P04 0 to 0.4MPa P10 0 to 1.

Thin pressure gauge. G401-W Series. Symbol Descriptions. A Connection A A. B Pressure display [MPa] P04 0 to 0.4MPa P10 0 to 1. Thin pressure gauge G401-W Series Thin, compact design ideal for incorporating devices. Suitable for filter regulator, regulator, and pressure switch (P4000-W). onnection: O ring seal, set screw G401-W

More information

ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9 uto Feed Lube, uto Feed Tank LF00 to 900, -/-9 Standard Specifications uto feed lube uto feed tank LF00 LF00-0 LF00 LF00 LF00 LF900 - --IS- -9 IR : OIL : Fluid Proof pressure ir. MPa Max. operating pressure

More information

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119 Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,

More information

Index Table. Model 794. Installation, Operating and Maintenance Instructions

Index Table. Model 794. Installation, Operating and Maintenance Instructions CLOCKWISE MANUAL MAKING INTO CCW TABLE Index Table Model 794 Installation, Operating and Maintenance Instructions Black & Webster Products Division 545 Hupp Ave. P.O. Box 831, Jackson, Michigan 49204 2009

More information

LMU100/200 Series. Standard Specifications

LMU100/200 Series. Standard Specifications Mist Spray Unit MU/ Series Intermittent spray to cutting and press gear chains, etc. Standard Specifications Inlet air Oil tank set range Oil Dynamic viscosity of oil ( C) Oil tank capacity (cm ) mbient

More information

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0) Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk WIRE ROPE CUTTER WCS75HDZ PRODUCT CODE No. 980482 INSTRUCTIONS FOR

More information

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut Regulator for 2 MPa RX 2 How to Order RX2 1 Regulator 1 Regulating pressure.5 to.85mpa {.51 to 8.7kgf/cm²}.5 to.3mpa {.51 to 3.1kgf/cm²} Thread type Nil N F Rc(PT) NPT (PF) Port size 1 2 ccessories/options

More information

Hydraulic Piston Accumulators

Hydraulic Piston Accumulators Hydraulic Installation All accumulators shipped from the factory will be pre-charged to a nominal pressure in order to seat the piston on the hydraulic cap. In this case the precharge will not be listed

More information

Whisper Pump Service and Repair Guide

Whisper Pump Service and Repair Guide VPV Vane Pump Whisper Pump Service and Repair Guide Hydraulics Welcome to the Service Guide for the VPV Pump! Dear Customer: First of all we would like to thank you for choosing the Bosch VPV Pump. This

More information

SFC. SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement DESCRIPTION & APPLICATIONS: ADVANTAGES:

SFC. SKYLINE FLOW CONTROLS INC. The Leader of Accurate and Reliable Flow Measurement DESCRIPTION & APPLICATIONS: ADVANTAGES: SKYLINE FLOW CONTROLS INC. SFC Skyline Flow Controls Wedge Meter (SFC-WM) The SFC wedge meter is a differential pressure device for use on all fluids. It is especially designed for slurries and liquids

More information

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation, Operation and Maintenance Manual for Back Pressure Regulator Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN

More information

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K Modular Type Regulator Series R Regulator Series R Model R M5 x.8 ccessory R2 /8, /4 R /4, 3/8 R3 /4, 3/8 R4 /4, 3/8, /2 Pages 36 through 4 Regulator with back flow mechanism Series RK R4-6 R5 R6 R2K RK,

More information

Full Range Pressure Compensating Variable Flow Control

Full Range Pressure Compensating Variable Flow Control Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever

More information

Proportional Throttle Cartridges, Size 16

Proportional Throttle Cartridges, Size 16 Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact

More information

CA14 SG Iron Air and Gas Trap ½" and ¾" (Screwed)

CA14 SG Iron Air and Gas Trap ½ and ¾ (Screwed) ert. No. LRQ 9638 ISO 91 14 SG Iron ir and Gas Trap ½" and ¾" (Screwed) TI-P148-1 ST Issue 6 escription The 14 is a range of float type automatic liquid drainers for air and gas systems. The body and cover

More information

005 Series Modular Valves

005 Series Modular Valves 5 Series Modular Valves ype of Modular Valve Class Graphic Symbols age Solenoid Operated Directional Valve DSG-5- *** - * - ressure Control Valves Flow Control Valves Directional Control Valves Modular

More information

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C Exercise 2-3 EXERCISE OBJECTIVE C C C To describe the operation of a flow control valve; To establish the relationship between flow rate and velocity; To operate meter-in, meter-out, and bypass flow control

More information

ALE-32. Miniature General Purpose Regulators R07, R46 (non-repairable) Air line equipment. Technical data

ALE-32. Miniature General Purpose Regulators R07, R46 (non-repairable) Air line equipment. Technical data ir line equipment Miniature eneral Purpose egulators 7, (non-repairable) 7 Full flow gauge ports Snap action knob locks pressure setting when pushed in Standard relieving models allow reduction of outlet

More information

vacon nx ac drives hxm120 cooling unit, ss-piping commissioning and maintenance manual

vacon nx ac drives hxm120 cooling unit, ss-piping commissioning and maintenance manual vacon nx ac drives hxm120 cooling unit, ss-piping commissioning and maintenance manual WARNING HOT SURFACE! NOTE WARNING HOT SURFACE! NOTE 11571_uk WARNING ! NOTE! NOTE WARNING! NOTE Secondary

More information

MECHANICALLY OPERATED DIRECTIONAL VALVES Rotary Type : DRT/DRG-02 Cam Operated : DCT/DCG-01, 03 Threaded Connection/Sub-plate Mounting

MECHANICALLY OPERATED DIRECTIONAL VALVES Rotary Type : DRT/DRG-02 Cam Operated : DCT/DCG-01, 03 Threaded Connection/Sub-plate Mounting MCHNICLLY ORD VLVS Rotary ype : DR/DRG- Cam Operated : DC/DCG-, hreaded Connection/ Mounting General Information Up to 5 Ma (6 SI), L/min (6. U.S.GM) ub. C-6 hese valves are chiefly used to shift the pilot

More information

vacon nx ac drives hxl040 cooling unit, ss-piping commissioning and maintenance manual

vacon nx ac drives hxl040 cooling unit, ss-piping commissioning and maintenance manual vacon nx ac drives hxl040 cooling unit, ss-piping commissioning and maintenance manual WARNING HOT SURFACE! NOTE WARNING HOT SURFACE! NOTE 11571_uk WARNING ! NOTE! NOTE WARNING! NOTE Additional

More information

APP pumps APP and APP Disassembling and assembling

APP pumps APP and APP Disassembling and assembling Service guide APP pumps APP 11-13 and APP 16-22 Disassembling and assembling hpp.danfoss.com Table of Contents Contents 1. Introduction... 2 2. Disassembling the pump... 3 3. Assembling the pump... 6 4.

More information

42 Series. Pneumatic. Lever / Pedal Valves 4-Way, 5-Port, 2 & 3-Position. Section Q. Pneumatic

42 Series. Pneumatic. Lever / Pedal Valves 4-Way, 5-Port, 2 & 3-Position. Section Q. Pneumatic 42 eries Lever / edal Valves 4-Way, -ort, 2 & -osition ection asic Valve unctions...2 42 eries asic Valve eatures... ommon art Numbers...4 odel Number Index... tacking anifold ystems...6 imensions Lever

More information

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94 Vickers Flow Controls Flow Controls FN, F(C)G, FRG Released 6/94 685 Table of Contents FN03/06/10 Model Series Application Data...............................................................................

More information

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K Modular Type Regulator Series R Regulator Series R Model R M5 x.8 ccessory R2 /8, /4 R /4, 3/8 R3 /4, 3/8 R4 /4, 3/8, /2 Pages 36 through 4 Regulator with back flow mechanism Series RK R4-6 R5 R6 R2K RK

More information

Directional Valves. Hydraulic Operated Directional Valves

Directional Valves. Hydraulic Operated Directional Valves Service Data Vickers Directional Valves Hydraulic Operated Directional Valves (F*) DG3V 8 (B) ** (L) (X) (*) (*) 10 (EN**) Released 04/96 5007.03/EN/0496/S DG3V-8-*(C) - (X) - 10 Spring Centered 473726

More information

Series ACG/ARG/AWG. Regulator with Built-in Pressure Gauge Filter Regulator with Built-in Pressure Gauge

Series ACG/ARG/AWG. Regulator with Built-in Pressure Gauge Filter Regulator with Built-in Pressure Gauge Regulator with uilt-in ressure auge ilter Regulator with uilt-in ressure auge Series /R/W - - - R- L- W- R L W V Visibility of pressure gauge is improved in various installation places When mounting on

More information

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual WHEATLEY SERIES 500 SWING CHECK VALVE STANDARD INTEGRAL SEAT & OPTIONAL REMOVABLE SEAT 2" FP - 6" FP 150# - 1500# 8" FP - 12" FP 150# - 900# API 6D and B16.34 2" FP - 4" FP 5000# DRILLING PRODUCTION VALVE

More information

Directional Controls

Directional Controls Vickers Directional Controls Lever Operator Directional Control Valves DG17S-8-**-10 DG17S4-10 **-50 NF D08/D10, ISO-4401-08/10 Released 5/94 681 able of Contents General Information..................................................................................

More information

4400 TwinHybrid Gas Seal

4400 TwinHybrid Gas Seal 4400 TwinHybrid Gas Seal EQUIPMENT PREPARATION MECHANICAL SEAL INSTALLATION INSTRUCTIONS 1 2 200.005" 0,13 mm 125 µ" 3,2 µm R a 3 4 32 µ" 0,8 µm R a 1000 ±.002" 0,05mm CAUTIONS These instructions are general

More information

ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential

More information

SPC*01 (2-way) SPC03/06 (2-way) Size NG6 NG10 NG16 NG25 DIN A10 ISO 4401 NFPA D05 CETOP 5 P, A, B:

SPC*01 (2-way) SPC03/06 (2-way) Size NG6 NG10 NG16 NG25 DIN A10 ISO 4401 NFPA D05 CETOP 5 P, A, B: Catalog HY14-255/US Technical Information General Description sandwich type pressure s are typically used in combination with proportional directional control valves. The keeps the pressure drop over the

More information

Liquid Level Controls

Liquid Level Controls Series RS High Pressure Sensors & Probes For onductance ctuated ontrols Series RS Sensors Series-RS-X-BR-: NM 4X nclosure For sophisticated multi-level control in tanks, boilers and hydronic systems Remote

More information

Horizontal Bladder Tanks

Horizontal Bladder Tanks DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

No October, Eaton. Gear Pumps. Parts Information. Series 26 Model Single Gear Pumps

No October, Eaton. Gear Pumps. Parts Information. Series 26 Model Single Gear Pumps Eaton Gear Pumps No. 6-634 October, 1995 Parts Information Series 26 Model 26000 Single Gear Pumps Pump Parts Drawing Righthand (CW) pump rotation shown. 14b 17 11 4D 1 25 9 4A 10 4B 14a 40 Plug 3 7 13

More information

Pressure switches for air and water CS

Pressure switches for air and water CS Data sheet Pressure switches for air and water CS CS pressure switches have a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the

More information

Hand & mechanical directional valves

Hand & mechanical directional valves www.atos.com Table E5-3/E Hand & mechanical directional valves ISO 44 sizes 6,, 6 and 25 H- Hand & mechanical operated directional valves are spool type, three or four way, two or three position valves,

More information

Medium Pressure Valves, Fittings and Tubing Pressures to 21,000 psi

Medium Pressure Valves, Fittings and Tubing Pressures to 21,000 psi Medium Pressure Valves, ittings and Tubing MXMTOR has been designing and manufacturing high pressure equipment for more than thirty years and has a worldwide reputation for quality and reliability, backed

More information

Model VR6 System. Installation, Operation & Maintenance

Model VR6 System. Installation, Operation & Maintenance Model VR6 System Installation, Operation & Maintenance General: All Archer Instruments chlorination systems are carefully designed and tested for years of safe, accurate field service. All Archer Instruments

More information

SpeciÞcations. Engine Dimensions Dimensions in millimeters. Inch equivalents shown in [].

SpeciÞcations. Engine Dimensions Dimensions in millimeters. Inch equivalents shown in []. SpeciÞcations Engine Dimensions Dimensions in millimeters. Inch equivalents shown in []. Ê ßÔ Ê ÛÝ Ñ Ê Û ÎÊ Û É 5 ENGINE IDENTIFICATION NUMBERS Kohler engine identiþcation numbers (model, speciþcation

More information

Vertical Bladder Tanks

Vertical Bladder Tanks DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

FLOW CONTROL VALVES FLOW CONTROL VALVE HF WITH PRESSURE COMPENSATION SIZE 01 E 4. Description of the model designation. Outside dimensions

FLOW CONTROL VALVES FLOW CONTROL VALVE HF WITH PRESSURE COMPENSATION SIZE 01 E 4. Description of the model designation. Outside dimensions FLOW CONTROL VALV HF WITH PRSSUR COMPNSATION SIZ it incorporates a pressure compensation mechanism, the flow is kept constant even if the pressure varies at the and/or port. When equipped with a check

More information

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8 and 1/4 PTF Port Sizes. Air line equipment. Air line equipment R Miniature Brass Body Regulator Water and Compressed Air Service 1/" and 1/" PTF Port Sizes Compact design, corrosion resistant construction Brass body with choice of plastic or brass

More information

Introduction. Part one: Identify the Hydraulic Trainer Components

Introduction. Part one: Identify the Hydraulic Trainer Components The University Of Jordan School of Engineering Mechatronics Engineering Department Fluid Power Engineering Lab Experiments No.4 Introduction to Hydraulic Trainer Objective: Students will be able to identify

More information

Technical Data. Approvals UL and C-UL Listed FM Approved. Maximum Working Pressure 250 psi (7,2 bar) Friction Loss Refer to Graphs A and B

Technical Data. Approvals UL and C-UL Listed FM Approved. Maximum Working Pressure 250 psi (7,2 bar) Friction Loss Refer to Graphs A and B Worldwide ontacts www.tyco-fire.com Model Pipe Line Strainer General Description The welded steel body Model Pipe Line Strainers (Ref. Figures 1 and 2) are designed for installation in the water supply

More information

Disassembling and assembling APP and APP 16-22

Disassembling and assembling APP and APP 16-22 MAKING MODERN LIVING POSSIBLE Instruction Disassembling and assembling APP 11-13 and APP 16-22 ro-solutions.com Table of Contents 1. Disassembling...3 2. Disassembling the pump...3 3. Assembling the pump....7

More information

Check valve hydraulically pilot operated

Check valve hydraulically pilot operated Check valve hydraulically pilot operated RE 6/7.5 Replaces:. / Types SV and SL Nominal sizes to Component series X Maximum operating pressure 5 bar Maximum flow 55 l/min H555 Overview of contents Contents

More information

MEGR-1912 Instruction Manual

MEGR-1912 Instruction Manual MEGR-1912 PRESSURE REGULATOR Instruction Manual- Look Inside For: Description Installation Start-Up Maintenance Parts Ordering Parts List Marshall Excelsior Company Marshall, MI 49068 269-789-6700 FAX

More information

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES INSTRUCTION MANUAL Installation Operation Parts Service IMPORTANT Record your Regulator model number and serial number here for easy reference: Model No. Serial No. Date of Purchase When ordering parts

More information

Directional Controls

Directional Controls Vickers Directional Controls Directional Control Valves DG3V-3-*-60 Hydraulic Operated DG17V-3-*-60 Lever Operated DG18V-3-*-60 Air Operated DG20V-3-*-60 Cam Operated DG21V-3-*-60 Plunger Operated CETOP

More information

Direct Operated Precision Regulator Modular Style. Standard Specifications

Direct Operated Precision Regulator Modular Style. Standard Specifications 1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com

More information

Bollard Post, Model R-8902

Bollard Post, Model R-8902 ollard Post, Model R-80 Removable Receiver with Lid (for detail, see sheet of ) Removable Receiver with hain (for detail, see sheet of ) Fixed Embedded Mount (for detail, see sheet of ) Flanged Surface

More information

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09. Meter out pressure compensator Sandwich plate design Type SCA... /Series X Sizes 6, 5 up to 35 bar up to 35 L/min RE 9 47/.96 RE 9 47/.96 Replaces: 9.87 Sandwich plate design Load compensation in lines

More information

B2KL: 6-way ball valve with male thread, PN 16

B2KL: 6-way ball valve with male thread, PN 16 Product data sheet 3.1 58.001 K: 6-way ball valve with male thread, PN 16 How energy efficiency is improved fficiency means precise control and low actuating forces eatures 6-way ball valve for changeover

More information

Double Pilot Operated Cartridge Check Valve, Size 8

Double Pilot Operated Cartridge Check Valve, Size 8 Double Pilot Operated Cartridge Check Valve, Size 8 Q max = 7 l/min (19 gpm), p max = 35 bar (5 psi) pilot operated, two-stage, spring-closed cartridge-type poppet valve Compact design for cavity type

More information

Pilot operated check valves 4CG

Pilot operated check valves 4CG Pilot operated check valves 4CG unctional Symbols Model Code External 外部ドレン形 drain type ( 3 )- 4 C G - 3 -( D ) - -( G E 5 )- J -( S 1 )- J 1 3 4 5 6 7 Internal 内部ドレン形 drain type Valve can function to

More information

ISO Sub-bases. Port sizes G 1 /4 - G1 and 1 /4NPT - 1 /2NPT. Sub-bases tovdma specification, for ISO sizes #1, #2, #3 and #4

ISO Sub-bases. Port sizes G 1 /4 - G1 and 1 /4NPT - 1 /2NPT. Sub-bases tovdma specification, for ISO sizes #1, #2, #3 and #4 Port sizes 1 / - 1 and 1 /NPT - 1 /NPT Sub-bases tovd 3 specification, for ISO sizes #1, #, #3 and # Universal bases for ISO sizes #1 and #, side and bottom ported Technical Data edium: See individual

More information

INSTALLATION, OPERATING & MAINTENANCE MANUAL WATER DRAIN VALVE

INSTALLATION, OPERATING & MAINTENANCE MANUAL WATER DRAIN VALVE INSTALLATION, OPERATING & MAINTENANCE MANUAL WATER DRAIN VALVE Contents 1 Introduction 1. Introduction... 3 2. Specification... 4 3. Installation... 7 4. Operation...11 5. Maintenance...14 This Water Drain

More information

3-Way Pressure-Reducing Cartridge, Size 2 4

3-Way Pressure-Reducing Cartridge, Size 2 4 -Way Pressure-Reducing Cartridge, Size 2 Q max = 2 l/min, p max = 25 bar Spool-type design, direct acting, with manual adjustment 1 Description Compact construction for cavity type AM /- UNF to Bucher

More information

K Page 1 of 48 Air Intake - Pg. 17

K Page 1 of 48 Air Intake - Pg. 17 K532-53168 Page 1 of 48 Air Intake - Pg. 17 Ref # Part Number Qty Description 24 25 041 06-S 1 Gasket, elbow 25 48 054 09 1 Elbow, air cleaner Discontinued not available at Kohler Co. 35 277116-S 1 Brace,

More information

Agilent 1220 Infinity II LC Mobile Upgrade Kit

Agilent 1220 Infinity II LC Mobile Upgrade Kit Agilent 1220 Infinity II LC Mobile Upgrade Kit Note 1220 Infinity II LC Mobile Upgrade Kit This note describes the procedures to install an Mobile Upgrade kit to an existing Agilent 1220 Infinity II LC.

More information