Oklahoma Corporation Commission Oil & Gas Conservation Division Post Office Box Oklahoma City, Oklahoma Rule 165:

Size: px
Start display at page:

Download "Oklahoma Corporation Commission Oil & Gas Conservation Division Post Office Box Oklahoma City, Oklahoma Rule 165:"

Transcription

1 Oklahoma Corporation Commission Oil & Gas Conservation Division Post Office Box Oklahoma City, Oklahoma Rule 65: Form 002A AP No.: OTC Prod. Unit No.: Amended Amend Reason: RETURN TO PRODUCNG Completion Report Spud Date: August 0, 978 Drilling Finished Date: August 7, 978 st Prod Date: December 5, 978 Completion Date: December 5, 978 Recomplete Date: December 26, 206 Drill Type: STRAGHT HOLE Well Name: SKNNER-BARR -9 Purchaser/Measurer: Location: Operator: ALFALFA 9 27N W C NW SE 980 FSL 660 FWL of /4 SEC Derrick Elevation: 0 Ground Elevation: 20 NELSON NC COUNTY ROAD 800 NASH, OK First Sales Date: Completion Type Location Exception ncreased Density X Single Zone Multiple Zone There are no Location Exception records to display. There are no ncreased Density records to display. Commingled Casing and Cement Type Size Weight Grade Feet PS SAX Top of CMT SURFACE 8 5/8 24 / 32 K-55 / S SURFACE PRODUCTON 4 /2 0.5 K Liner Type Size Weight Grade Length PS SAX Top Depth Bottom Depth There are no Liner records to display. Total Depth: 5429 Packer Plug Depth Brand & Type Depth Plug Type 5225 OTS PERMATREVE There are no Plug records to display OTS PUNCH OUT nitial Test Data January 23, 207 of 2

2 Test Date Formation Oil BBL/Day Oil-Gravity (AP) Gas MCF/Day Gas-Oil Ratio Cu FT/BBL Water BBL/Day Pumpin or Flowing nitial Shut- n Pressure Choke Size Flow Tubing Pressure Dec 26, 206 MSSSSPP CHAT 25 FLOWNG 200 Completion and Test Data by Producing Formation Formation Name: MSSSSPP CHAT Code: 40MSSCT Class: GAS Spacing Orders Perforated ntervals Unit Size From To Acid Volumes There are no Acid Volume records to display. Fracture Treatments There are no Fracture Treatments records to display. Formation Top WOLFCAMP 903 OSWEGO 497 CHEROKEE 503 Were open hole logs run? No Date last log run: Were unusual drilling circumstances encountered? No Explanation: RED FORK 5242 MSSSSPP CHAT 5292 MSSSSPP 5323 Other Remarks There are no Other Remarks. FOR COMMSSON USE ONLY Status: Accepted January 23, of 2

3 orrated. Retied PLEASE TYPE CML USE BLACK NA OPLY NOTE Attach coca/ of original 002A if Tecomptetion or ttraita y. ENDED CReaseri? h.) ț roevc. ) TYPE-OF DRLLNG OPERAT/ON el,mstraght HOLE7ORECTONAL RaE.MHORZONTAL HOLE t tseeheicr vscu_ felseedonal or Andeontal,. see reverseforeenornbdelacation...'a i A.: t..-e a,;v.:a.7,0..3.e, 4,,, a.f.a.5,. NEL. fii, -...ft-,4.,..!fst. of..r2 vx FANLOF i OKLAHOMA -.amporaton CORMSSON. OS sae CorseNalion Division Poet Office 9ox OMAY,Nne CST, OkAaesena Rule 65: COMPLETON REPORT SPUD DATE e_,...7e3.... F--/7L4 ORTO FNSHED DATE NAM j.-- r-- tio i!...6 al PROD DATE DATE OP WELL 2 5-le. COMPLETON % ' i 2,.../5,7b,(,,,,..... r,-, "- -/4 SEC /77.0.' i.4 SEC DUL --- ELEVATO GrowAn y, N Dente g ) Lena7ade ta Amen) OPERATOR i j. t.e OTC00C i 9, tile, rr-,oputatcr NO. 0 ' i i A.-.74,-;20 DEC OKLAHOMA COUOR ON COMM: Forrn672A. Rev. 20CPE ADDMSS. 2.ilei COMPLETON TWE X SNGLE ZONE TAULt PLE ZONE Applicata::Date COMMNGLED isoik0._._. LOCATON EXCEETADN OWTES3 NMEASED DENSTY ORDFR NO PACKER t/saca C BRAND & TYPE PACKER ittry.2s". BRAND Y. TY COMPLETON A TEST DATA BY PROOlC FORMATON SPAVNG &SPACNG ORXR NUMEreR CLASS Ot Gas. Cry, re, OW Coen asp, Svc zr 4 PLUG a PLUG g FORMATON STATE 07 ZA. [ e :e -K-- 7 CASNG &CEMENT form 60W must be seta LOCATE WELL TYPE SZE WEGHT i GRADE FEET i P5 SAX OF CONDUCTOR, j -[ _x f : i SU ACE._9:/:kj,LckL_ ''' i5' ; 2, b,57..LT -4 NTERMEDATE.0 cqv 4,...f_ 44 5-cg 9 lirs-0 3 PRODUCTON J LNER TYPE PLUG TYPE TYPE 'PLUG a TYPE //33-c.-2r : Tmpr OTAHL PERFORATED NTERVALS ACDNOLUME FRACTURE TREATMENT (F}Lins-Prep,Anotait0 YETAL TEST OATA Min Gas AUsevable OR Agowable el85:ea-2-m 7-7 Gas Purtlreseni First &Hee Cele OL-BEALMAY OLGRA75TY i.ak.7, GAS-MCFDAY 7 / GAS-OL RA700.! /BBL S SUBMTED EATER-BBL/DAY, G DAMNS TiALSHLT PRESSURE :YOKE SZE Yi , s 4NfTAL3EST DA _ r i -.5,- f.,,, le-- aovithalto. URE A mead QAT. twtegal6 Ce. im angle,.and serenest roma-.am presented Or Me mem_ dadare eldi f tiswo knowledge ra.ihecuments of nialepartand ain aueann.e7 by my 59pushon As maks Ras L Mee,. was prepared by Tee tamer rnysupereisien and &ecos leen the data wal Mrs Mama herem 6 be. eve, corred. and corraawe WSW beaa i7, sti leasaense mal 'Wiest.--4--?,... dviii-, Air!..t) il 'fflt 2 "i's 523`)/30.73`7 A X.. SGNATURE RAW (PRNT OR TYPE) DATE -PHONENUMBER i :67 t,.4,..) ts..) 0D, -- -"Tisk -o- "± / Aft,- e_4,...,,,,,,...,!address Cn-Y STATE ZP EMML ADDRESS -

4 wils PLEASE TYPE OR USE BLAcK NK ONLY FORMADON RECORD Give formation names and tops, ifi availabte or descriptions and *Witness of ion-natio-a &Bad througfi- Shay intervas cored or tritstern tested O -PASE NAME NELL0, NAMES OF FORMATONS,' i PCE.. p 0 '56.(ț Ci... jie,#,i't e r., g.td Fa-k 09',-sf "jfrị J3 TOP i503 45/? 5/03 5--Dzsi L 502,-;- 53?-3. FOR CONAPSSON USE CHAN rres on ft -res =No APPROVED DSAPPROVED 2) Rejecs Codes Were open hole kogs rim? Dale Last log mos nin Was C05 encomtered? HA encaalmed? Yes yes fle at what depths? yes no at **at deriths? Were urarsoal *Who sinnanssmos encountered? *yes, briefly explaribblow ynn 93 Other fern 640 Actes BOTTOM HOLE LOCATON FOR DRECTONAL liole EC TNm SpotLacation 04 Measwell TWA: Dap%!RGE /4 COUNTY /4 Feet From /4 Sec Llries 4 True Velfbcal Death.3L FTOM Lease, Unit. or Properly Urw BOTTOM HOLE LOCATON FOR HORZONTAL HOLE (LATERALS) f moat., three drarthales ara an... separaie sheef egeadmg he neoessarrinfernwen." Deed., musthe owed. degree...na Meade nate, the Narmada drainade and its end poet TOO. be Mated within the baundadas alas lease er spaeleg aler Diretlional surveys are-required fore strentotes :and clirecuonal -64( Acres LATERAL * SEC rrtie Spot Losallon /4 Depth of /4 /4 RadO or T Deviation Measired Tole/ Depth!This vortical Depth LATEStAL *2 SEC MAP Spot Location 4 Depth of Del/taboo Measured TWADepth Feet Front /4 Sec Lines FSL Oireclion iotal LengM,3HL From Lease, Ur*, er*tdperly - :RGE COUYTY i 3. ifee /4 4 -!Rad. of Turn, Direction "-otal. ;Length!True Veredd Depth lehl Frwn Lease. Unit, or Property Line:,im ffrern -4 See iros F-sL - PA*. LATERAL SEC WP!ROE COUNTY Spot Location 4Feet Ffern 4 Sec U..!FSL /4 /4 /4 of iradbz ortom pirection ifatal Length Twat!True Vertical Depth SM_ From -ease, Unit Properly Une:

5 co3- Olgrj fr 0933 AM NO CZ) u6n7 OTC. NocoleM 00R-GNAL Re ht --_sqamended freemea.. TYPE OF DRLLNG OPERA, ON OR ME Ru(.7( NK ONLY NOTE:. Attach copy d original 002A if recompietion or teeny. PrO0 vc ; v),..:ṅlestradtff- BD-EFDRECTONALliCaB r HORZONTAL HOLE. L /SERNCE WELL f chmthmal ot horizonta, see WE 000=00 ocalion...n-f-aftl ti. Et )426( OKLAHOMA CORPDRATORCORMSSON Oil -GeaConsenation Dvisice Post Moe Bea Oktstorne City, OldatKana M 6"'"2' OKLAHOMA CO RPOR COMPLEGON REPORT COMM C '.0.c '.640 Aum SPUD DATE ET- i -7e. ORLO FNSHED s. 7,7E, DATE - '..0', if...e. /5 mw-rge P A.,,,TEZT,'. ) WEL ;,,,,o. /.,. s PROD DATE,.2.../s,..7e gild /4 fr /4 /4 /47- F t5 At. FWL F 56A NSEC / m-- i Urr SEC - " L ELEVATO 4 Dest0t. Ground ' Bantus* ft known) LongitorM ManiNat OPERATOR A) 9 NAME, e i ut., OTC4/00 ADDRESS etre/63 R EC"'DATE /2,-. 2icit,,)0 t OPERATOR NO. LEASE i. NAME itt-'0}p t.- -, 3.4,- 3.- DEC Rev 2XE 06EZ sk STATE bk. - n''' & CEMENT Form 002C mast be attached PACKER fg.t;- BMOC TYPEPX PACKER arri,26. BRAND TyPECtr p.,, 4,),PLUG g COMPLETON & TEST DATA BY PRODUCNG F DON CONDZTOR TYPE SZE GHT GRADE FEEf PS SAX TOP OF i ' SURFACE.5'.' ' vii,-.. /7.- -:... NTERN ATE (.. j,,,- C! X 0. ti PRODUCTON.00, LNER,,,, g y5-0.os l i 5-:,c,,,,a /- 4 ] 50 TDOT E AL 5f,d } SPA-ZNGS SPACNG ORDER NUMEER aass, Ot. Gas, Dry, nj. law Comm 8. PERFORATED NTERVALS,7. f i f6" E C-TURE TPS-ATMENT fffaartai,lop ArroatnN Min Gas Alkoamate (66D-7-m Gas Puichasealheeseret OR Fast Sakes Date -TEST DATA OlAilo lea :UN% TN_ TEST - -., Ga.-BBL/DAY,,,,,,,... :"frir OL-GRANTY t APG GAS-MCFDAY GAS-OL RATOat FTB-M_ NATER4MLDAY [ / i AS SUBMTED PUMPNG OR FLOWNG NT,v_ SH:r4s PRESS.. - SZE, ri..eo Ols ' '... '.aillttgritas.., /D 0 - FlowmeiraGrFsssuRE i A teasel of the tornmaors (Mace Melt, arm cerimma (entaasafe tasseled on themwetse. dectam man haw latowledge or the contents of Ws report SW MR audvaued try rny ogisrmathan to make Ws, a., water was m-exaed by ale or urvie-my supervisionand weak., vth,the &is ft lapis Matadi-re:min to be tlue, cornea, end complete lathe hem tem lesseamims and lastmt. "zrap. ).eri' /'e ;L"'...a...-Te'' >...,.^ - SGNATURE NAVE (PRNT OR TYPE) ifel C3-34z4- DATE f,hone NUMBER \..,..,, e itot.-2,-:,,e-4-t (/0?5-(46 6,...-4-,.., ft JCAO "4--- Ok 73 6/, 7 mt..) ADDRESS ' CTY STATE ZP L., EMAL ADDRESS a:amed

Oklahoma Corporation Commission Oil & Gas Conservation Division Post Office Box Oklahoma City, Oklahoma Rule 165:

Oklahoma Corporation Commission Oil & Gas Conservation Division Post Office Box Oklahoma City, Oklahoma Rule 165: Oklahoma Corporaton Commsson Ol & Gas Conservaton Dvson Post Offce Box 52000 Oklahoma Cty, Oklahoma 73152-2000 Rule 165: 10-3-25 Form 1002A AP No.: 35149215290000 OTC Prod. Unt No.: 149-205146 Completon

More information

Oklahoma Corporation Commission Oil & Gas Conservation Division Post Office Box Oklahoma City, Oklahoma Rule 165:

Oklahoma Corporation Commission Oil & Gas Conservation Division Post Office Box Oklahoma City, Oklahoma Rule 165: Oklahoma Corporation Commission Oil & Gas Conservation Division Post Office Box 52000 Oklahoma City, Oklahoma 73152-2000 Rule 165: 10-3-25 Form 1002A AP No.: 35051235810000 OTC Prod. Unit No.: 051-207824

More information

Oklahoma Corporation Commission Oil & Gas Conservation Division Post Office Box Oklahoma City, Oklahoma Rule 165:

Oklahoma Corporation Commission Oil & Gas Conservation Division Post Office Box Oklahoma City, Oklahoma Rule 165: Oklahoma Corporation Commission Oil & Gas Conservation Division Post Office Box 52000 Oklahoma City, Oklahoma 73152-2000 Rule 165: 10-3-25 Form 1002A API No.: 35073254870000 OTC Prod. Unit No.: 073-218559

More information

Oklahoma Corporation Commission Oil & Gas Conservation Division Post Office Box Oklahoma City, Oklahoma Rule 165:

Oklahoma Corporation Commission Oil & Gas Conservation Division Post Office Box Oklahoma City, Oklahoma Rule 165: Oklahoma Corporation Commission Oil & Gas Conservation Division Post Office Box 52000 Oklahoma City Oklahoma 73152-2000 Rule 165: 10-3-25 Form 1002A AP No.: 35129235130000 OTC Prod. Unit No.: 129-206450

More information

Oklahoma Corporation Commission Oil & Gas Conservation Division Post Office Box Oklahoma City, Oklahoma Rule 165:

Oklahoma Corporation Commission Oil & Gas Conservation Division Post Office Box Oklahoma City, Oklahoma Rule 165: Oklahoma Corporaton Commsson Ol & Gas Conservaton Dvson Post Offce Box 52000 Oklahoma Cty, Oklahoma 73152-2000 Rule 165: 10-3-25 Form 1002A AP No.: 35043231380001 OTC Prod. Unt No.: 043-205416 Completon

More information

RAILROAD COMMISSION OF TEXAS OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG

RAILROAD COMMISSION OF TEXAS OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG RAILROAD COMMISSION OF TEXAS 1701 N. Congress P.O. Box 12967 Austin, Texas 78701-2967 Status: Form W-2 OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG Date: Tracking No.: Approved 03/16/2016

More information

RAILROAD COMMISSION OF TEXAS OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG

RAILROAD COMMISSION OF TEXAS OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG RAILROAD COMMISSION OF TEXAS 1701 N. Congress P.O. Box 12967 Austin, Texas 78701-2967 Status: Form W-2 OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG Date: Tracking No.: Approved 06/29/2015

More information

Oil Well Potential Test, Completion or Recompletion Report, and Log

Oil Well Potential Test, Completion or Recompletion Report, and Log Tracking No.: 15871 Status: Submitted RAILROAD COMMISSION OF TEXAS Oil and Gas Division API No. 42- Oil Well Potential Test, Completion or Recompletion Report, and Log 1. FIELD NAME (as per RRC Records

More information

RAILROAD COMMISSION OF TEXAS OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG

RAILROAD COMMISSION OF TEXAS OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG RAILROAD COMMISSION OF TEXAS 1701 N. Congress P.O. Box 12967 Austin, Texas 78701-2967 Status: Form W-2 OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG Date: Tracking No.: Approved 10/13/2015

More information

Oil Well Potential Test, Completion or Recompletion Report, and Log

Oil Well Potential Test, Completion or Recompletion Report, and Log Tracking No.: 16947 Status: Submitted RAILROAD COMMISSION OF TEAS Oil and Gas Division API No. 42- Oil Well Potential Test, Completion or Recompletion Report, and Log 1. FIELD NAME (as per RRC Records

More information

RAILROAD COMMISSION OF TEXAS OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG

RAILROAD COMMISSION OF TEXAS OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG RAILROAD COMMISSION OF TEXAS 1701 N. Congress P.O. Box 12967 Austin, Texas 78701-2967 Status: Date: Tracking No.: Form W-2 OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG Submitted

More information

RAILROAD COMMISSION OF TEXAS OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG

RAILROAD COMMISSION OF TEXAS OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG RAILROAD COMMISSION OF TEXAS 1701 N. Congress P.O. Box 12967 Austin, Texas 78701-2967 Status: Form W-2 OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG Date: Tracking.: Approved 03/11/2015

More information

Oil Well Potential Test, Completion or Recompletion Report, and Log

Oil Well Potential Test, Completion or Recompletion Report, and Log Tracking No.: 102948 Status: Submitted RAILROAD COMMISSION OF TEXAS Oil and Gas Division API No. 42- Oil Well Potential Test, Completion or Recompletion Report, and Log 1. FIELD NAME (as per RRC Records

More information

Colorado Oil and Gas Conservation Commission (COGCC) Completed Interval Report, Form 5A Data Field Definitions

Colorado Oil and Gas Conservation Commission (COGCC) Completed Interval Report, Form 5A Data Field Definitions NOTE: Changes to the Form 5A, effective June 1, 2012, to accommodate the disclosure requirements are indicated by a preceding asterisk (*) and bold italics. All other fields are unchanged. FORM 5A HEADING

More information

Colorado Oil and Gas Conservation Commission

Colorado Oil and Gas Conservation Commission Colorado Oil and Gas Conservation Commission http://cogcc.state.co.us/ FORM 5A Completed Interval Report INDUSTRY TRAINING Denver, Colorado November 27, 2012 Form 5A Completed Interval Report Introduction

More information

OIL/GAS WELL COMPLETION REPORT. Well Name and Number Surveyed elevation (feet): KB GL

OIL/GAS WELL COMPLETION REPORT. Well Name and Number Surveyed elevation (feet): KB GL 1800 Washingn Blvd. Baltimore Maryland 21230 OIL/GAS WELL COMPLETION REPORT Permit No. Name of Operar Address Well Name and Number Surveyed elevation (feet): KB GL Well Location Field (If wildcat, so state)

More information

Terrace Petroleum Corporation Cunning Wolf UL No. 602H, 1980 FNL and 467 FWL Section 6, Block 23, ULS Pecos County, Texas

Terrace Petroleum Corporation Cunning Wolf UL No. 602H, 1980 FNL and 467 FWL Section 6, Block 23, ULS Pecos County, Texas Terrace Petroleum Corporation Cunning Wolf UL No. 602H, 1980 FNL and 467 FWL Section 6, Block 23, ULS Pecos County, Texas 3-29-13 DAY 1 Previously built location, roads, built and lined reserve pits. Move

More information

Casing and Cementing Requirements

Casing and Cementing Requirements Directive PNG005 May 2018 Revision 2.0 Governing Legislation: Act: The Oil and Gas Conservation Act Regulation: The Oil and Gas Conservation Regulations, 2012 Order: 148/18 Record of Change Revision Date

More information

D & V Oil Co. LP. Daily Completion Report - University CN A #6 API # /23/2016. Perfs ' ' Activity :

D & V Oil Co. LP. Daily Completion Report - University CN A #6 API # /23/2016. Perfs ' ' Activity : Daily Completion Report - University CN A #6 API # 42-105-42334 12/23/2016 Activity at Report Time: Perfs - 2512' - 2632' Depth at Report Time Put Well on Production 2655' - PBTD Activity : Arrive Location.

More information

OIL AND GAS DOCKET NO

OIL AND GAS DOCKET NO OIL AND GAS DOCKET NO. 09-0239466 THE APPLICATION OF KEY ENERGY SERVICES, INC. - NTD FOR COMMERCIAL DISPOSAL AUTHORITY FOR ITS JEFF MOSER LEASE, WELL NOS. 1 AND 2, CHICO, WEST (CONGLOMERATE 5700) FIELD

More information

BLACK HILLS PLATEAU PRODUCTION COMPANY

BLACK HILLS PLATEAU PRODUCTION COMPANY BLACK HILLS PLATEAU PRODUCTION COMPANY DRILLING PROGRAM Homer Deep Unit 9 11CH SHL: 300 FNL, 200 FWL, NWNW Sect. 9 T8S R98W BHL: 1350 FSL, 2100 FEL NWSE Sect. 15 T8S R98W Garfield & Mesa Counties, Colorado

More information

BEFORE THE CORPORATION COMMIS OF THE STATE OF OKLAHOMA MID-CONTINENT, INC. DRILLING AND SPACING UNIT NEWFIELD EXPLORATION MID-CONTINENT, INC.

BEFORE THE CORPORATION COMMIS OF THE STATE OF OKLAHOMA MID-CONTINENT, INC. DRILLING AND SPACING UNIT NEWFIELD EXPLORATION MID-CONTINENT, INC. APPLICANT: BEFORE THE CORPORATION COMMIS 1 LIILE OF THE STATE OF OKLAHOMA EB 0$ 2012 COURT CLERKI OFP NEWFIELD EXPLORATION MID-CONTINENT, INC. * TULSA CoRPOA11N COMMINION OF OKLAHOMA RELIEF SOUGHT DRILLING

More information

Directive 059: Well Drilling and Completion Data Filing Requirements

Directive 059: Well Drilling and Completion Data Filing Requirements Directive 059 Directive 059: Well Drilling and Completion Data Filing Requirements December 19, 2012 Effective June 17, 2013, the Energy Resources Conservation Board (ERCB) has been succeeded by the Alberta

More information

ENDEAVOR ENERGY RESOURCES

ENDEAVOR ENERGY RESOURCES ENDEAVOR ENERGY RESOURCES Lease WELL NO FIELD PBTD PERFORATIONS FOREMAN TOOLPUSHER API NUMBER DATE University 5-20-21 #1H 14,223' Tony Cody 07/02/13 OART WEATHER FLUID SUMMARY W/O UNIT DATA W/L UNIT DATA

More information

REPORT GEO-TECHNICAL INVESTIGATION FOR THE PROPOSED BLOCK-7 SUB-STATION SY NO-225, NEAR RAYACHERLU VILLAGE

REPORT GEO-TECHNICAL INVESTIGATION FOR THE PROPOSED BLOCK-7 SUB-STATION SY NO-225, NEAR RAYACHERLU VILLAGE REPORT ON GEO-TECHNICAL INVESTIGATION FOR THE PROPOSED BLOCK-7 SUB-STATION SY NO-225, NEAR RAYACHERLU VILLAGE CLIENT: KARNATAKA SOLAR POWER DEVELOPMENT CORPORATION BANGALORE 0 GEO-TECHNICAL INVESTIGATION

More information

Appalachian Basin Gas Well. Marietta College, Marietta, Ohio June 7-8, Development. Robert McKee, P.E. Design Engineer Multi Products Company

Appalachian Basin Gas Well. Marietta College, Marietta, Ohio June 7-8, Development. Robert McKee, P.E. Design Engineer Multi Products Company Appalachian Basin Gas Well Marietta College, Marietta, Ohio June 7-8, 2010 Casing Plunger Applications & Development Robert McKee, P.E. Design Engineer Multi Products Company Casing Plunger A.L. Lift Without

More information

APPENDIX A1 - Drilling and completion work programme

APPENDIX A1 - Drilling and completion work programme APPENDIX A1 - Drilling and completion work programme Information about the well and drilling To the extent possible, the international system of units (SI) should be adhered to, and the drilling programme

More information

DEPARTMENT OF ENVIRONMENTAL PROTECTION Office of Oil and Gas Management

DEPARTMENT OF ENVIRONMENTAL PROTECTION Office of Oil and Gas Management DEPARTMENT OF ENVIRONMENTAL PROTECTION Office of Oil and Gas Management DOCUMENT NUMBER: 800-0810-003 TITLE: EFFECTIVE DATE: AUTHORITY: POLICY: PURPOSE: APPLICABILITY: DISCLAIMER: Guidelines for Development

More information

REPORT GEO-TECHNICAL INVESTIGATION FOR THE PROPOSED BLOCK-1 SUB-STATION SY NO-44, NEAR KYATAGANACHERLU VILLAGE

REPORT GEO-TECHNICAL INVESTIGATION FOR THE PROPOSED BLOCK-1 SUB-STATION SY NO-44, NEAR KYATAGANACHERLU VILLAGE REPORT ON GEO-TECHNICAL INVESTIGATION FOR THE PROPOSED BLOCK-1 SUB-STATION SY NO-44, NEAR KYATAGANACHERLU VILLAGE CLIENT: KARNATAKA SOLAR POWER DEVELOPMENT CORPORATION BANGALORE 0 GEO-TECHNICAL INVESTIGATION

More information

Key Ward Information - Cowes South and Northwood (part of the Cowes cluster of wards)

Key Ward Information - Cowes South and Northwood (part of the Cowes cluster of wards) Key Ward Information - Cowes South and Northwood - 2017 (part of the Cowes cluster of wards) This report has been designed to support provide data and information about Cowes South and Northwood and compare

More information

WellTracer. East Texas Gas Producers Association. Carthage, Texas September 21 st, 2010

WellTracer. East Texas Gas Producers Association. Carthage, Texas September 21 st, 2010 WellTracer East Texas Gas Producers Association Carthage, Texas September 21 st, 2010 Welltracer Gas Lift Diagnostics What methods are available for diagnosing leak points and or gas lift efficiency? Diagnostic

More information

A Longer Lasting Flowing Gas Well

A Longer Lasting Flowing Gas Well 2018 Artificial Lift Strategies for Unconventional Wells Workshop Cox Convention Center, February 4 7, 2018 A Longer Lasting Flowing Gas Well New Dual-Tubing Flowing Design Paul Edwards, Production Engineer,

More information

Drilling Morning Report

Drilling Morning Report REPORT DATE 5/0/200 Report # AFE # Casing OD(in) WT(lbs/ft) Grade Btm MD(ft) Btm TVD(ft) DCRB04 TVD: 32 MD: 32 Progress: 32 Planned TD:,500 Current Hole Size: Days From Spud: Spud Date: 5//0 Days on Well:

More information

Kerry A. Pollard Texstar Midstream Utility, LP Gallon E. Gray Phillip Zamzow EXAMINER S REPORT AND RECOMMENDATION STATEMENT OF THE CASE

Kerry A. Pollard Texstar Midstream Utility, LP Gallon E. Gray Phillip Zamzow EXAMINER S REPORT AND RECOMMENDATION STATEMENT OF THE CASE OIL AND GAS DOCKET NO. 01-0271975 THE APPLICATION OF TEXSTAR MIDSTREAM UTILITY, LP FOR AUTHORITY PURSUANT TO STATEWIDE RULES 9 AND 36 TO DISPOSE OF OIL AND GAS WASTE CONTAINING HYDROGEN SULFIDE INTO THE

More information

Investor Update. January 2015

Investor Update. January 2015 Investor Update January 215 215: Embracing Market Change Revised 215 capex and production guidance $2.7 billion capex (reduced 41%) Targeting cash flow neutrality by mid year 215 Other Drilling, $12MM

More information

S h o w S p e c i a l s

S h o w S p e c i a l s T R I D E N T ' s 2 0 1 8 S h o w S p e c i a l s Special prices are good on orders received and shipped between November 14 and December 1, 2018 WE WILL ALSO MATCH OUR COMPETITORS DEMA SPECIALS ON SAME

More information

Railroad Commission of Texas

Railroad Commission of Texas Workshop Railroad Commission of Texas Casing, Cementing, Drilling Well Control, and Completion Requirements Chairman Houston, Barry Texas T. Smitherman Commissioner David J. Porter Commissioner December

More information

PROPOSED NEW SUB- CODE 1 RIG UP AND TEAR. Possibly Fits into Existing Code. 7/26/2018 Review PROPOSED NEW CODE EXISTING OPERATION

PROPOSED NEW SUB- CODE 1 RIG UP AND TEAR. Possibly Fits into Existing Code. 7/26/2018 Review PROPOSED NEW CODE EXISTING OPERATION NW NW 1 RIG UP AND TAR 1 no sub-code RIG UP AND TAR DOWN Start: Rig released from previous well, nd: Rig fully rigged up, acceptance tests successfully completed, and signed off. DOWN 1 1 Rig Under Tow

More information

Continental Industries STEEL SERVICE TEES or FAX Visit

Continental Industries STEEL SERVICE TEES or FAX Visit Continental Industries STEEL SERVICE TEES 1-800-558-1373 or FAX 1-800-788-1668 Visit www.conind.com ABOUT US Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and

More information

OBSOLETE DESIGN DATA. CONCENTRATE CONTROLLERS 2, 3", 4", 6" and 8" (50, 80, 100, 150, and 200 mm)

OBSOLETE DESIGN DATA. CONCENTRATE CONTROLLERS 2, 3, 4, 6 and 8 (50, 80, 100, 150, and 200 mm) March 1, 2001 Foam 210 a 1. PRO DUCT NAME Viking Concentrate Controller 2,, (102 mm) (152 mm), (203 mm) Available since 1996. 2. MANUFACTURED FOR THE VIKING COR PO RA TION 210 North Industrial Park Road

More information

Representing EXAMINERS REPORT AND PROPOSAL FOR DECISION STATEMENT OF THE CASE

Representing EXAMINERS REPORT AND PROPOSAL FOR DECISION STATEMENT OF THE CASE OIL AND GAS DOCKET NO. 03-0231502 THE APPLICATION OF JOHNSON SANFORD OPERATING COMPANY TO AMEND ITS PERMIT TO DISPOSE OF OIL AND GAS WASTE BY INJECTION INTO A POROUS FORMATION PRODUCTIVE OF OIL OR GAS,

More information

Division of Environmental Quality Wellhead Protection Section

Division of Environmental Quality Wellhead Protection Section Division of Environmental Quality Wellhead Protection Section 1 10 CSR 23-3.110 Plugging of Wells Any well which is to be abandoned must be plugged in accordance with these rules. If a well has been determined

More information

Call To Action. & bb b b b. w w. œ œ œ J. &b b b b b. œ œ œ. œ œ. œ œ œ. ? b b b b b 4. j œ. j œ Ó n. œ j. œ j œ œ Ó Œ. œ j Ó Œ j œœ œ Ó.

Call To Action. & bb b b b. w w. œ œ œ J. &b b b b b. œ œ œ. œ œ. œ œ œ. ? b b b b b 4. j œ. j œ Ó n. œ j. œ j œ œ Ó Œ. œ j Ó Œ j œœ œ Ó. Voice Piao q=132 Comissioed by the Australia Museum of Democracy (MoAD) Call To Actio 4 By Tim Bevitt 2017 q=132 & bb b b b4 w w J 4 6 &b b b b b &b b b b b 10 µ J E F w w b We Our live here i Aus-tral

More information

Are We There Yet? IPv6 as Related to GDP per Capita. By Alain Durand November 28 th,` 2016

Are We There Yet? IPv6 as Related to GDP per Capita. By Alain Durand November 28 th,` 2016 Are We There Yet? as Related to By Alain Durand November 28 th,` 2016 Quesons for this Study: I. Where are we across the globe with adoption? a. Is deployed uniformly? b. Is there a rich country/poor country

More information

Texas Administrative Code

Texas Administrative Code TITLE 16 PART 1 CHAPTER 3 RULE 3.13 Texas Administrative Code ECONOMIC REGULATION RAILROAD COMMISSION OF TEXAS OIL AND GAS DIVISION Casing, Cementing, Drilling, Well Control, and Completion Requirements

More information

Mobeetie Resource Dev LLC EXAMINER S REPORT AND RECOMMENDATION STATEMENT OF THE CASE

Mobeetie Resource Dev LLC EXAMINER S REPORT AND RECOMMENDATION STATEMENT OF THE CASE OIL AND GAS DOCKET NO. 10-0262937 THE APPLICATION OF MOBEETIE RESOURCE DEV LLC FOR A PERMIT TO DISPOSE OF FLUID CONTAINING HYDROGEN SULFIDE INTO A RESERVOIR NOT PRODUCTIVE OF OIL OR GAS, BUD HOGAN SWD

More information

INSTRUCTIONS FOR COMPLETING FORM H-9 STATEWIDE RULE 36 CERTIFICATE OF COMPLIANCE

INSTRUCTIONS FOR COMPLETING FORM H-9 STATEWIDE RULE 36 CERTIFICATE OF COMPLIANCE INSTRUCTIONS FOR COMPLETING FORM H-9 STATEWIDE RULE 36 CERTIFICATE OF COMPLIANCE 1. The certificate of compliance shall certify that operator has complied, or will comply, with applicable provisions of

More information

Copper Compression Connectors

Copper Compression Connectors Copper Compression Connectors CONNECTORS SERIES PAGE Short Copper Splices...SCC Series...51 Copper Splices...CC Series...52 Tapered Copper Splices...TCC Series...53 Straight Oil-Stop Copper Splices...OCC

More information

Continental Industries TRANSITION FITTINGS or FAX Visit

Continental Industries TRANSITION FITTINGS or FAX Visit Continental Industries TRANSITION FITTINGS 1-800-558-1373 or FAX 1-800-788-1668 Visit www.conind.com ABOUT US Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and

More information

FMT PRESSURE RESULTS CRETACEOUS AND BRENT GROUP PF PSIH PHA PSIA

FMT PRESSURE RESULTS CRETACEOUS AND BRENT GROUP PF PSIH PHA PSIA _ FMT PRESSURE RESULTS CRETACEOUS AND BRENT GROUP WELL 3/-3A NO/ TEST NO MRKB, MD PHI PSIA PF PSIH PHA PSIA REMARKS / /2 /3 /4 / /6 / / / / / /2 /3 /4 / /6 2/ 2/2 2/3 2/4 2/ 2/6 2/ 2/ 3/ 3/2 4/ / /2 /3

More information

Practice Exam IADC WellSharp Driller and Supervisor

Practice Exam IADC WellSharp Driller and Supervisor Workover & Completion Day 4 1. In a workover operation of a shut in well a Lubricator is being used together with a Wireline BOP / Wireline Valve. Which Barrier is classified as the Primary Barrier? A.

More information

Petr 311 Wellbore pressures and Kick Control

Petr 311 Wellbore pressures and Kick Control etr 311 Wellbore pressures and Kic Control Reeber b. 05D Consider the wellbore static hydraulic syste The pressures in the drill string and the annulus can be represented as a U-tube. The su of the pressures

More information

Form 21 Mechanical Integrity Test

Form 21 Mechanical Integrity Test Form 21 Mechanical Integrity Test Instructions for completing the Form 21, Mechanical Integrity Test for submission in eform. Required for eform submission Completed test form from field (please see Practices

More information

Total Frequency Percent CAPS Graduate Graduate Intensive English

Total Frequency Percent CAPS Graduate Graduate Intensive English Total Enrollment Fall, Fall I 2006: 8150 All Students by School All Students By Status CAPS & Traditional UG 4722 57.9 Continuing 5926 72.7 Graduate 3406 41.8 First-time Freshman 911 11.2 Intensive English

More information

New power in production logging

New power in production logging New power in production logging Locating the zones where fluids enter the wellbore in a producing or injecting well is an important aspect of production logging. It is relatively straightforward to establish

More information

TAM Single SeT inflatable

TAM Single SeT inflatable TAM Single SeT inflatable ReTRievAble PAckeRS Sets with pressure only Releases with straight pull or rotate Ideal for horizontal applications Sets in casing or open hole Runs on tubing, coiled tubing,

More information

DEPARTMENT OF ENVIRONMENTAL PROTECTION Office of Oil and Gas Management

DEPARTMENT OF ENVIRONMENTAL PROTECTION Office of Oil and Gas Management DEPARTMENT OF ENVIRONMENTAL PROTECTION Office of Oil and Gas Management DOCUMENT NUMBER: 800-0810-003 TITLE: EFFECTIVE DATE: AUTHORITY: POLICY: PURPOSE: APPLICABILITY: DISCLAIMER: Guidelines for Development

More information

STATE OF MICHIGAN DEPARTMENT OF NATURAL RESOURCES LANSING. 16 April 2013

STATE OF MICHIGAN DEPARTMENT OF NATURAL RESOURCES LANSING. 16 April 2013 STATE OF MICHIGAN DEPARTMENT OF NATURAL RESOURCES LANSING DNR DEPARTMENT OF NATURAL RESOURCES MICHIG AN April 0 Allegan County Board of Commissioners Chestnut Street Allegan, MI 4900 Dear Allegan County

More information

Railroad Commission of Texas. Chairman Barry T. Smitherman Commissioner David Porter Commissioner Christi Craddick

Railroad Commission of Texas. Chairman Barry T. Smitherman Commissioner David Porter Commissioner Christi Craddick Railroad Commission of Texas Chairman Barry T. Smitherman Commissioner David Porter Commissioner Christi Craddick 1 RRC Regulations Primary directives: - Prevent Waste - Promote Conservation - Protect

More information

NEW PROGRAM! OIL AND GAS TECHNOLOGY PROGRAM

NEW PROGRAM! OIL AND GAS TECHNOLOGY PROGRAM NEW PROGRAM! PROGRAM Mechanical Maintenance MODEL H-IRT-1 Industrial Refrigeration Trainer MODEL H-RIG-1C Rigging Systems Trainer MODEL H-IMTS-1 Industrial Maintenance Training System MODEL H-FP-223-14

More information

High Cost Gas Statewide Rule 101 (Tight Formations)

High Cost Gas Statewide Rule 101 (Tight Formations) RAILROAD COMMISSION OF TEXAS High Cost Gas Statewide Rule 101 (Tight Formations) Stephan Paetzold, Engineering Unit Overview What is High Cost Incentive and Statewide Rule (SWR) 101 Background How to Obtain

More information

Perforation Design for Well Stimulation. R. D. Barree Barree & Associates LLC

Perforation Design for Well Stimulation. R. D. Barree Barree & Associates LLC Perforation Design for Well Stimulation R. D. Barree Barree & Associates LLC Typical Shaped Charge Primer charge Main explosive charge Case or container Detonating cord groove ¾ point of initiation Liner

More information

More than a Membership...

More than a Membership... More than a Membership... Are you looking for the best Golf Membership value in the Calgary & surrounding area? How about a challenging course with a great atmosphere? You ve come to the right place. No

More information

Limit of changes in transmissivity

Limit of changes in transmissivity K77 Eplaato Tasmssvt of Lae. -, (ft /da), -,, -,, -,, -,, -,, -, 4 3, - 7, g u l a 7, -,, -, o e e t telope, -, qufe pump test wt test umbe (see Table 4) 9 4 Lmt of cages tasmssvt 7 3 8 R de Ve 6 ve ll

More information

FREQUENTLY ASKED QUESTIONS

FREQUENTLY ASKED QUESTIONS What are some applications in which you ve successfully used this product? New Completions - Stage by Stage Diversion Between Frac plugs for Intra-Stage Diversion Replace Frac Plugs with Perf PODs - Full

More information

Casing Design. Casing Design. By Dr. Khaled El-shreef

Casing Design. Casing Design. By Dr. Khaled El-shreef Casing Design By Dr. Khaled El-shreef 1 Casing Design CONTENTS Function of Casing Casing Types & Tools Strength Properties Casing Specification Casing Design 2 1 RUNNING AND CEMENTING CASING Reasons for

More information

Low pressures to high pressures - how regional overpressure mapping helps find trapped hydrocarbons

Low pressures to high pressures - how regional overpressure mapping helps find trapped hydrocarbons Finding Petroleum Conference London: January 2010 Low pressures to high pressures - how regional overpressure mapping helps find trapped hydrocarbons Richard Swarbrick & Stephen O Connor GeoPressure Technology

More information

PROPOSED RECOMMENDATIONS BY THE LOUISIANA ASSESSORS ASSOCIATION OIL & GAS COMMITTEE TO THE LOUISIANA TAX COMMISSION FOR TAX YEAR 2018

PROPOSED RECOMMENDATIONS BY THE LOUISIANA ASSESSORS ASSOCIATION OIL & GAS COMMITTEE TO THE LOUISIANA TAX COMMISSION FOR TAX YEAR 2018 PROPOSED RECOMMENDATIONS BY THE LOUISIANA ASSESSORS ASSOCIATION OIL & GAS COMMITTEE TO THE LOUISIANA TAX COMMISSION FOR TAX YEAR 2018 (Proposed text to be deleted from previous tax year Rules and Regulations

More information

What a Wonderful World

What a Wonderful World What a Wonderful World For SATB voices Original words & music by George David Weiss and Bob Thiele 120 S Aah, A - lo ha, O - ha - n - a, sun's shi-ning love ly day-hey... flowers bl - oo-ming, skies bl

More information

1. The rate of flow from a well is controlled by surface and bottom-hole. 2. Usually, the rate is changed by adjusting a (surface/ subsurface) choke.

1. The rate of flow from a well is controlled by surface and bottom-hole. 2. Usually, the rate is changed by adjusting a (surface/ subsurface) choke. UNIT 1 CHOKE SELECTION AND ADJUSTMENT Exhibits 1 through 4 are placed in the center of the book so that they may be removed easily for reference. Please remove them now so that you will have them available

More information

EP WELLS DAILY OPERATIONS REPORT Report 29 05/19/2017

EP WELLS DAILY OPERATIONS REPORT Report 29 05/19/2017 5/2/27 5:23:5 Report Version: 4..6R9 Generated from data in EDM/Opens/PROFILE Report 29 5/9/27 Company Type WBS No/API No PERMIAN Development UNIVERSITY 9 PW UNIT 56H UNIVERSITY 9 PW UNIT 56H 32656 / 4233326.

More information

Reclassification and Recompletion

Reclassification and Recompletion Reclassification and Recompletion Guideline PNG024 September 2015 Revision 1.0 Governing Legislation: Act: The Oil and Gas Conservation Act Regulation: The Oil and Gas Conservation Regulations, 2012 Record

More information

ASX Announcement. Target Energy Fairway Reserves Update. Corporate information. 20 September 2017

ASX Announcement. Target Energy Fairway Reserves Update. Corporate information. 20 September 2017 Target Energy Fairway Reserves Update Fairway Proven Reserves (net to Target) of 3.19 million barrels of oil equivalent (MMBOe) as of 30 June 2017 2017 update increases Fairway Proven Reserves by 11% Total

More information

Lightweight Roof Tiles Designed for Life. unique high performance shingles. Product Guide & Price List

Lightweight Roof Tiles Designed for Life. unique high performance shingles. Product Guide & Price List Lightweight Roof Tiles Designed for Life unique high performance shingles Product Guide & Price List Introducing the ExtraLight roof tiling system, a new and unique high performance textured tile. The

More information

Perforations Cleanup with Surge Chambers to Increase Well Productivity SLAP Jorge Patino, Halliburton. Oct 18 th, 19 th & 20 th, 2016

Perforations Cleanup with Surge Chambers to Increase Well Productivity SLAP Jorge Patino, Halliburton. Oct 18 th, 19 th & 20 th, 2016 Perforations Cleanup with Surge Chambers to Increase Well Productivity Jorge Patino, Halliburton SLAP 16-25 Oct 18 th, 19 th & 20 th, 2016 Slide 2 REVIVING MATURE FIELDS New technology has enabled oil

More information

Inkling Fan Language Character Encoding Version 0.3

Inkling Fan Language Character Encoding Version 0.3 Inkling Fan Language Character Encoding Version 0.3 What follows is a proposed encoding for the characters in the Inkling fan language for standardization among font creators. This encoding would make

More information

This in an internal Commission document provided to Industry for reference purposes only.

This in an internal Commission document provided to Industry for reference purposes only. FORM C EMERGENCY INCIDENT FORM BC Oil and Gas Commission 6534 Airport Road Fort St. John BC V1J 4M6 Phone: (250) 794-5200 emp@bcogc.ca This in an internal Commission document provided to Industry for reference

More information

W I L D W E L L C O N T R O L PRESSURE BASICS AND CONCEPTS

W I L D W E L L C O N T R O L PRESSURE BASICS AND CONCEPTS PRESSURE BASICS AND CONCEPTS Pressure Basics and Concepts Learning Objectives You will be familiarized with the following basic pressure concepts: Defining pressure Hydrostatic pressure Pressure gradient

More information

onlinecomponents.com

onlinecomponents.com Mounting Brackets E-L/F-L Slits/Reflectors E-S/E-R CSM_E-L_F-L_E-S_E-R_DS_E Mounting Brackets [Refer to Dimensions on page.] Model Fitting materials Count E-L Iron, zinc plating Accessories Applicable

More information

HEAVY DUTY PNEUMATIC

HEAVY DUTY PNEUMATIC HEAVY DUTY PNEUMATIC Series A4 MEDIUM DUTY HYDRAULIC Series H4 PERMANENTLY LUBRICATED HEAVY DUTY PNEUMATIC Series L4 586.778.7680 SERIES A4/L4/H4 39 A4/L4/H4 FEATURES 1 1 9 9 12 8 7 5 12 3 13 4 10 2 11

More information

Form MMS 123A1123S Electronic Version. Application. We have incorrect pressure tests for the annulars on subject ABP The ABP shows we

Form MMS 123A1123S Electronic Version. Application. We have incorrect pressure tests for the annulars on subject ABP The ABP shows we U.S Department of the Interior 0MB Control Number 1010-0141 Minerals Management Service MMS 0MB Approval Expires 08/31/2008 Form MMS 123A1123S Electronic Version Lease Area/Block Well Name ST 01 BP 00

More information

Hilti Tool Service Drill and Drive

Hilti Tool Service Drill and Drive Hilti Tool Service Drill and Drive ion SF 2-A 2016/01 1 N/A N/A SFD 2-A 2016/01 1 N/A N/A SF 14-A 2011/05 2 414 SFC 14-A 2011/04 2 311.00 Cordless Drill / Drive Cordless Impact Drive Cordless Impact Wrench

More information

Blowout during Workover Operation A case study Narration by: Tarsem Singh & Arvind Jain, OISD

Blowout during Workover Operation A case study Narration by: Tarsem Singh & Arvind Jain, OISD 1. Introduction An incident of gas leakage from a well took place during workover operations. Subsequently, the gas caught fire on the fourth day in which twelve persons were injured. Two contract workers,

More information

Abandonment Program for Paramount Fort Liard F 36

Abandonment Program for Paramount Fort Liard F 36 Abandonment Program for Paramount Fort Liard F 36 Well Name: Paramount et al Liard F 36 Area: 60 0 10 N, 123 0 15 W Location: Latitude: 60 0 05 27 Longitude: 123 0 22 00 UWI: 300F366010123150 WID: 1841

More information

Live well deployment of long perforating gun system using combined CT technologies

Live well deployment of long perforating gun system using combined CT technologies Live well deployment of long perforating gun system using combined CT technologies SPE ICoTA European Well Intervention Conference Aberdeen - 12 November, 2014 Simon Smith, Technical Support Manager Baker

More information

Coal Bed Methane (CBM) Permeability Testing

Coal Bed Methane (CBM) Permeability Testing Coal Bed Methane (CBM) Permeability Testing WTN Network Meeting April 28-29, 2011 ExxonMobil Exploration / Well Testing Team CBM Flow Characteristics Flow mechanism Gas desorbs when pressure drops below

More information

Completion or Recompletion Date: 11/17/2014 Date. Multiple completion? No

Completion or Recompletion Date: 11/17/2014 Date. Multiple completion? No RAILROAD COMMISSION OF TEXAS Form VU-2 J 1701 N. Congress $tetus: Submtted P.O. Box 12967 Date: os2o5 Austn, Texas 78701-2967 Trackng No.: z5s7a OIL WELL POTEfVTIAL TEST, COMPLETION OR 12EGOMPLETIOR9 REPORT,

More information

Disposal/Injection Well Pressure Test Report (H-5)

Disposal/Injection Well Pressure Test Report (H-5) RAILROAD COMMISSION OF TEXAS Disposal/Injection Well Pressure Test Report (H-5) Lauryn McFarland Engineering Technician Summary When Mechanical Integrity Test (MIT) is required How to file MIT How to perform

More information

Squeeze Cementing. Brett W. Williams Cementing Technical Advisor January 2016 Tulsa API Meeting

Squeeze Cementing. Brett W. Williams Cementing Technical Advisor January 2016 Tulsa API Meeting Squeeze Cementing Brett W. Williams Cementing Technical Advisor January 2016 Tulsa API Meeting Definition Squeeze Cementing is the process of applying hydraulic pressure to force or squeeze a cement slurry

More information

Friday 14 th September, 2012

Friday 14 th September, 2012 Friday 14 th September, 2012 Target Energy oil flow success as predicted in Darwin-1 well in Texas, USA In our previous coverage of Target Energy (ASX: TEX, Share Price: $0.098, Market Cap: $34m) in early

More information

HOW TO MAKE MORE PRODUCTION WITH PLUNGER LIFT

HOW TO MAKE MORE PRODUCTION WITH PLUNGER LIFT HOW TO MAKE MORE PRODUCTION WITH PLUNGER LIFT D E V E L O P I N G UNCONVENTIONAL G A S T E C H N I C A L W O R K S H O P M AR C H 2 9, 2 0 1 0 CONTENTS PLUNGER LIFT BENEFITS WITH TELEMETRY HOW TO OPTIMIZE

More information

Worked Questions and Answers

Worked Questions and Answers Worked Questions and Answers A Learning Document for prospective Candidates For the Rotary Drilling Well Control Test Programme Copyright, IWCF June 2000 Revision No.1, November 2000 IWCF 2000 page 1 of

More information

2017 Race Simulation Camp

2017 Race Simulation Camp 2017 Race Simulation Camp Toronto, Ontario January 8-14, 2017 Workout Log 2017 Race Camp Sunday PM LC 4X400 1 Fins 50 Free/50 Back 1 IM 50 K/50 S 1 IM 50 Dr/50 S 1 Swim Free NS by 10 seconds 5 rest at

More information

Pasquale Imbò e Marco Pelucchi ENI S.pA;

Pasquale Imbò e Marco Pelucchi ENI S.pA; 7th European Gas Well Deliquification Conference Innovative Failsafe Capillary Injection System Resolves Liquid Loading in Gas Well with a Cost- Effective Solution that Maintaining Production and Well-Safety

More information

GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS

GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS CONTINENTAL INDUSTRIES, INC. The Ultimate Connection CONTINENTAL INDUSTRIES, INC. ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, Inc.,

More information

W I L D W E L L C O N T R O L FLUIDS

W I L D W E L L C O N T R O L FLUIDS FLUIDS Fluids Learning Objectives You will learn about different fluids that can be used in well control. You will become familiar with the characteristics and limitations of fluids. You will learn general

More information

WELL NO: BJN-8. Lower master valve

WELL NO: BJN-8. Lower master valve WELL NO: BGN-8.; LOC: BGH Well BGN-8 came into production on 9 th Feb. 2009. Initially the FTHP = 4000 psi, CP=2400 psi and 5 1 / 2 9 5 / 8 annulus pressure = 600 psi. The well was produced at Baghjan

More information

Cartridge Valves Technical Information. Pilot operated check valves. Quick reference

Cartridge Valves Technical Information. Pilot operated check valves. Quick reference Quick reference Pilot to Open Model No. Description Flow* Pressure Page P RPC 4 NCS4/ Pilot Operated Check Valve, Pilot to Open l/min [ US gal/min] RPC 6 NCS6/ 5 l/min [7 US gal/min] CP45- SDC- l/min RPC

More information

OIL AND GAS DOCKET NO

OIL AND GAS DOCKET NO OIL AND GAS DOCKET NO. 09-0241077 THE APPLICATION OF GILBOW TANK TRUCK SERVICE, INC., TO DISPOSE OF OIL AND GAS WASTE BY INJECTION INTO A POROUS FORMATION NOT PRODUCTIVE OF OIL OR GAS, GILBOW WELL NO.

More information

SR MARINER DIGITAL DEPTH METER DDM- 1 DDM- 2 INSTALLATION INSTRUCTIONS

SR MARINER DIGITAL DEPTH METER DDM- 1 DDM- 2 INSTALLATION INSTRUCTIONS SR MARINER DIGITAL DEPTH METER DDM- 1 DDM- 2 INSTALLATION INSTRUCTIONS Congratulatio n s in choosing a high perfor m a n c e marine instru m e n t and welcome to the growing family of SR Mariner produc

More information