HyQuest Solutions Pty. Ltd.
|
|
- Letitia Osborne
- 5 years ago
- Views:
Transcription
1 INSTRUCTION MANUAL L GAS PURGE COMPRESSOR MODEL HS55V / HS55VDO/HS55VB Gas Purge Compressor- Model HS-55/DO/D DB HS Issue 2: 30/5/2014
2 CONTENTS Contents HS 55 & HS 55DO & HS 55DB GAS PURGE COMPRESSOR... 5 I GENERAL... 5 II PRODUCT OVERVIEW... 5 III UNPACKING YOUR HS 55/DO/DB... 6 IV TESTING YOUR SYSTEM... 6 V SPECIFICATION... 7 VI INSTALLATION... 9 Installing the Model HS 55/DO/DB... 9 Field Installation VII OPERATION (i) Normal Pumping Operation (ii) Manual Purge for HS 55 & HS 55DO (iii) Manual Purge for HS 55DB VIII MAINTENANCE IX BUBBLE RATE ADJUSTMENT X FAULT FINDING XI MOUNTING THE HS 55/DO/DB XII PART LIST HS 55 MAIN ASSEMBLY HS 55DO MAIN ASSEMBLY HS 55DB MAIN ASSEMBLY HS 55/DO REGULATOR ASSEMBLY HS 55DB REGULATOR ASSEMBLY HS 55/DO/DB COMPRESSOR HS 55/DO/DB DRYER MIST SEPARATOR HS 55/DO/DB DRYER MIST SEPARATOR AUTO PURGE VALVE HS
3 HS 55 RIVER LINE PURGE VALVE HS 55DO RIVER LINE PURGE VALVE XIII APPENDIX A GCO1P INSTALLATION GENERAL PERFORMANCE COMPARISON XIV APPENDIX B STANDARD ORIFICE INSTALLATION XV APPENDIX C HS 55/DO/DB TYPICAL INSTALLATIONS HS 55 TYPICAL INSTALLATION HS55 DO TYPICAL INSTALLATION HS55 DB TYPICAL INSTALLATION XV UPGRADING THE HS 55 DRYER/MIST SEPARATOR ASSEMBLY HS
4 HS
5 HS 55 & HS 55DO & HS 55DB GAS PURGE COMPRESSOR I GENERAL The HS-55/DO/DB has been designed to replace conventional nitrogen gas bottle supply bubble units/gas purge systems for water level measurement. The design of the unit centres on the tried and proven HyQuest Solutions Model HS23/DO/DB Dry Bubble Unit with Differential Regulator (BU07). The HS-55/DO/DB incorporates maintenance free Air Drying System that utilises an Auto Purge Valve for Auto Drain Moisture Traps to ensure the system is free of moisture. The effectiveness of the HS-55/DO/DB Dryer, Filter and Auto Purge Valve is such that the unit also removes all moisture is the air, thus helping to reduce aquatic growth at the river end. The unit is maintenance free for up to 5 years. II (i) PRODUCT OVERVIEW ORIFICE FEATURE The Model HS-55 comes with a single orifice and the HS-55DO comes with a dual orifice. The HS-55 is used in situations where siltation is not an issue and the level in the river can be measured using a single orifice. The HS-55DO consists of 2 orifices located at different heights from the river bed. Under normal condition the bottom orifice is active and the top orifice is inactive. The dual orifice application become beneficial in a situation where severe siltation appears and causes the blockage of the bottom orifice at which instance the valve of the bottom orifice (1) is closed and the valve of the inactive (top) orifice (2) is opened to keep the bubbler system operating. The Model HS-55DB comes with a dual bubbler application. It consists of bubbler systems with 2 orifices that can be operating simultaneously at different heights or same height from the river bed. The dual bubbler application becomes beneficial in a situation where water level need to be monitored at two different locations. (ii) MANUAL PURGE - MODEL HS-55/DO/DB The HS-55/DO incorporates a 3-Way switching valve for manual purging of the system. Continuous purging occurs when the valve is rotated to Purge, the river line is opened and the instrument line is closed. This is similar to Gas Bubbler Unit (Model HS23/DO) functions. The HS-55DB incorporates a lever for manual purging of the system. Continuous purging occurs when the purge valve is opened. This is similar to Gas Bubbler Unit (Model HS23) functions; when purge operation is performed ensure the instrument line is closed. HS
6 Voltage Regulator Protection If the compressor pump operates continuously for a long period of time or if the system voltage drops to 11V due to power supply failure, the voltage protection system will be activated. At 11V the compressor shuts down until the battery is recharged to 12V at which time the system will commence normal operation. This feature protects the system from continuous operation. III UNPACKING YOUR HS 55/DO/DB The carton should include: Model HS-55 or HS-55DO or HS-55DB Any Accessories you have ordered Please verify you have received these items. It is recommended that you visually inspect the HS-55/DO/DB to verify all components and connections are secure. For more details about HS-55/DO/DB Purge System (see the purge section in this manual). IV TESTING YOUR SYSTEM Before installing the HS-55/DO/DB, you may wish to test the system prior to going to the field. Testing the HS-55/DO/DB will familiarise you with the compressor in an environment where it is easy to work. The HS-55/DO/DB is designed to be mounted in a vertical position. The mist separator will not function properly if the unit is in a horizontal position. Once the HS-55/DO/DB is positioned, connect the power leads to an appropriate 12VDC power supply. Turn on power switch to start the compressor pumping. The pump will take approximately 4 minutes to fill the air tank to maximum pressure of 85 p.s.i, (600 Kpa) and will then automatically switch off. Connect to one of the outlet ports a short piece of river line tubing and secure the end into a container of water. Check the bubble rate setting as required (factory setting is equivalent to 80 bubbles per minute). If the bubble rate requires adjustment, (see page 16 for instructions). Please note, if the HS-55DO is not purchased with a WL2100D/WL3100 dry pressure transducer fitted, then the transducer used must be fitted or the sensor valves closed prior to the test operation commencing. There are two pressure gauges fitted to the HS-55/DO. The unit attached to the pressure regulator indicates the set feed pressure (factory set at 400 Kpa) this pressure should be retained at this setting, however, if adjustment is required, turn the supply regulator knob to achieve the required setting. The second pressure gauge is located on the side of the HS-55/DO indicates the air tank pressure. HS
7 V SPECIFICATION Power: Maximum Current: Average Current Draw: Compressor: Receiver Capacity: (Air Tank) Normal Operating Pressure Range: Duty Cycle: Maximum Head: Maximum Length: Maximum Purge Pressure: Minimum Purge Pressure: Differential Pressure: Purging: 12V d.c. (38 amp hour battery minimum). 30 Amps Approx. 50 ma (Based on 60 bubbles/min) Precision Piston 13.5 litres (3.5 U.S. Gallons) 60 p.s.i, (400 kpa) to 85 p.s.i, (600 kpa) Typically 12 hours per year at 60 bubbles/minute 30 Metres Water Level (River Line) 200 Metres (Using 3/8" O.D.x 1/8" I.D Tubing) 85 p.s.i, (600 kpa) 60 p.s.i, (400 kpa) 3 p.s.i, (20 kpa) to 5 p.s.i, (35 kpa) Manual - lever valve operation continuous Bubble Rate: Air Dryer/Auto Purge Valve: Environment: Pressure Connections: User selectable from 40 to 120 bubbles/minute. Bubble rate is set 40 bubble/min for GCO1 application (See page 15 for adjustment details). Up to 5 year maintenance free Automated Purge Valve Hydrophobic filter. -40 deg C to 60 deg C HS-55 1x Outlets 3/8" dia tube (River Line), instrument one 1/4 NPT Adaptor fittings available for most transducers HS-55DO 2 x Outlets 3/8" dia tube (River Line), instrument one 1/4 NPT Adaptor fittings available for most transducers HS-55DB 2 x Outlets 3/8" dia tube (River Line), instrument 2 x 1/4 NPT Adaptor fittings available for most transducers HS
8 Mass: Approx. 30 lbs, (13 kg) Dimensions: 24" H x 12" W x 15" D (610 mm x 305 mm x 380 mm) Packed Dimensions: Mass: 32" H x 16" W x 19" D (810 mm x 410 mm x 480 mm) Approx lbs, (32 kg) OPTIONAL ACCESSORIES: (i) Dry Pressure Transducer (Model WL3100/WL3100A). (Model WL2100D). (ii) ML1-420 Data Logger (iii) (iv) Pressure Line Orifice Fitting 1/8" I.D. x 3/8" O.D. heavy wall black polythene. SC M (1000 Ft) Roll SC M (328 Ft) Roll BU07 Small Diameter Orifice fitting OR GCO1P/SS Gas Chamber orifice fitting with adjustable stainless steel knuckle (v) Mounting Bench mounting bracket available ORDERING INFORMATION Model Details Pressure Transducer HS-55 Base Model Not available HS-55DO Dual Orifice Model Not available HS-55/WL2100D Base Model with Pressure WL2100D Transducer HS-55DO/WL2100D Dual Orifice Model with WL2100D Pressure Transducer HS-55/WL3100 Base Model with Pressure WL3100 Transducer HS-55DO/WL3100 Dual Orifice Model with Pressure Transducer WL3100 HS
9 VI INSTALLATION Installing the Model HS 55/DO/DB For proper installation of the HS-55/DO/DB, you will need: The HS-55/DO/DB Installation Kit (provided) Installation for your HS-55/DO/DB may vary according to your application. The Figures below illustrates the physical input/output connections on your HS-55/DO/DB. This drawing will help in determining where you should make your connections for power, ground, communications, and outlet to orifice and pressure to your sensor. HS 55 BASE MODEL (I/O) CONNECTIONS HS
10 MODEL HS 55DO (I/O) CONNECTIONS MODEL HS 55DB (I/O) CONNECTIONS HS
11 Field Installation (i) (ii) (iii) The HS-55/DO/DB must be wall mounted in a vertical position, with the compressor at the top. A mounting bracket can be provided for bench mounting (see drilling template in this manual). Connect your pressure sensor directly to the sensor valve or connect a pressure line between the valve and your pressure measurement device. If your measurement device has noncompatible connections, you will need to request adaptor fittings to suit. The manifold sensor valve for the transducer is ¼ NPT. The HS-55/DO/DB requires only one power source to power the compressor. This supply is typically a 12V, 38 amp hour minimum, long life re-chargeable battery with solar or mains charger. (iv) Connecting a Pressure Sensor The pressure sensor can be fitted directly to the sensor valve or connected using pressure fittings and connecting tube. The Figures below shows typical installations of a complete pressure measurement system. HS 55 TYPICAL INSTALLATION HS
12 NOTE: ONE ORIFICE IS IN OPERATION ONLY HS 55DO TYPICAL INSTALLATION NOTE: BOTH ORIFICES ARE IN OPERATION HS 55DB TYPICAL INSTALLATION HS
13 VII OPERATION (i) Normal Pumping Operation During normal operation, When the tank pressure drops to about 60 p.s.i (400 Kpa), the pressure switch powers up the compressor recharging the receiver to 85 p.s.i (600 Kpa). This should take about 2 minutes. At the end of the pumping cycle the air dryer/mist separator valve will automatically operate releasing all moisture out of the system and ensuring clean dry air continue to flow into the compressor tank on the next pumping operation. (ii) Manual Purge for HS 55 & HS 55DO This feature allows the operator to purge the system during routine service visits. WARNING: PLEASE READ THE FOLLOWING INSTRUCTIONS PRIOR TO OPERATION 1. The above diagram indicates the river orifice line is open for normal bubbler operation. 2. Close position indicates the river line is closed to the bubbler system. 3. Purge position permits the river line to be purged at full tank pressure for a short duration. Note: Ensure transducer valve is closed prior to purge operation. 4. Allow pressure to stabilise after purging for approximately 10 minutes prior to opening transducer valve. During the purge operation, the active orifice (1) or (2) should produce vigorous bubbling with the tank pressure falling to approximately 400Kpa (60 p.s.i.) after about 30 seconds. At this point the compressor will be activated to recharge the air receiver. If further purging is required, the compressor should be allowed to refill the tank to maximum pressure 600 kpa (85 p.s.i). At the completion of the purge sequence, the compressor will resume the normal bubble operation. WARNING: Ensure sensor valve is closed prior to purging. Reopen sensor valve approximately 5 to 10 minutes after purging to allow system pressure to drop to normal bubbling rate. HS
14 (iii) Manual Purge for HS 55DB This feature allows the operator to purge the system during routine service visits. A purge is carried out by turning the manual purge lever either left or right depending on which orifice line requires purging. During this time, the orifice should produce vigorous bubbling with the tank pressure falling to approximately 400Kpa (60 p.s.i.) after about 30 seconds. At this point the compressor will be activated to recharge the air receiver. If further purging is required, the compressor should be allowed to refill the tank to maximum pressure 600 kpa (85 p.s.i). At the completion of the purge sequence, the compressor will resume the normal bubble operation. WARNING: Ensure sensor valve is closed prior to purging. Reopen sensor valve approximately 5 to 10 minutes after purging to allow system pressure to drop to normal bubbling rate. HS
15 VIII MAINTENANCE The HS-55/DO/DB is almost maintenance-free. You will need to ensure e that your power supply is sufficient for the equipment that you have installed. As the compressor s dutyy cycle is a few f minutes every 24 hours, it willl last for many years. The voltage sensor prevents the HS-55/DO/DB from running continuously for long periods of time. This will protect thee pump andd many other components of the HS-55/DO/DB in case off a system leaks or other malfunctions. All fittings must be secure. At 80 bubbles/minutes, even a tiny leakk will alloww the entire gas flow to escape. It is recommended in yearly bases to check the compressor for the following: 1- Leaks: this is done by spraying a leek detector around the fitting and ensuring all fitting are tight. 2- Check all the wire terminals and battery voltage as battery life varies between 2-5 years depending on the manufacturer and the life span of the battery. 3- Check the mist separator filter status thiss is done as follows: a) Ensure compressor is off and batteryy is disconnected b) Push the quick release fitting to undoo the tube connected too the mist separator housing c) Undo the mist separator housing by turning anti-clockwise d) Check the mist separatorr state if require replacement part no. n is SC ; please turn the mist separatorr anti-clockwise to undoo and replace. e) To re-assemble reverse steps d,c, andd b and turn compressor back on. Step a Push & Hold Pull Gas Purge Compressor- Model HS-55/DO/D DB HS Issue 2: 30/ /5/2014
16 Step b Step c Gas Purge Compressor- Model HS-55/DO/DB HS Issue 2: 30/5/2014
17 IX BUBBLE RATE ADJUSTMENT The chart below has been prepared to show the relationship between the bubble rate at the test orifice and the equivalent rates that would be observed on a sight glass bubble unit. Once the desired bubble rate has been achieved tighten the screw to lock the Nupro valve. Actual Bubble Rate setting at Test Orifice or River Line (bubbles/min) Suitability Equivalent Site Glass Bubble Rate (bubbles/min) Suitable for low rising streams Suitable for Fast rising streams 200 Recommended setting for Gas Chamber Orifice, Model GC01P installations Note: Bubble rates detailed above are only an approximate guide for the purpose of conserving gas and have no influence on the performance of the transducer. Example: To adjust the HS-55DO to the equivalent of 80 bubbles per minutes, the Nupro valve should be rotated anticlockwise if the bubble rate is below this amount, or clockwise if bubble rate is above 80 per minute. There should be 21 bubbles per minute emerging from the test orifice. HS
18 X (i) (a) (b) (ii) FAULT FINDING HS-55/DO/DB Not Powering Up Check battery voltage Check all connections including POWER and GROUND. Both the compressor and control power sources must be connected. Intermittent Operation Check your power and ground connection. Moisture over time, will oxidize and corrode connectors and pins; Verify your power supply or battery voltage. XI MOUNTING THE HS 55/DO/DB DRILL HOLE SIZE HS
19 XII PART LIST HS 55 MAIN ASSEMBLY HS
20 HS
21 HS 55DO MAIN ASSEMBLY HS
22 HS
23 HS 55DB MAIN ASSEMBLY HS
24 HS
25 HS 55/DO REGULATOR ASSEMBLY HS
26 HS
27 HS 55DB REGULATOR ASSEMBLY HS
28 HS
29 HS 55/DO/DB COMPRESSOR HS
30 HS 55/DO/DB DRYER MIST SEPARATOR DRYER MIST SEPARATOR GPC07A HS
31 HS 55/DO/DB DRYER MIST SEPARATOR AUTO PURGE VALVE MIST SEPARATOR AUTO PURGE VALVE GPC07B HS
32 HS 55 RIVER LINE PURGE VALVE HS
33 HS 55DO RIVER LINE PURGE VALVE HS
34 XIII APPENDIX A GCO1P INSTALLATION GENERAL The HyQuest Solutions Gas Chamber Orifice (GCO1P/SS is designed to replace the standard orifice in a gas purge water level measurement system. The GCO1P /SS permits the use of extremely low bubble rates with increased sensitivity and near total reduction of lag between actual level rise and orifice pressure. It can also operate satisfactorily when buried under up to 1m of silt. Bubble rates as low as 10 bubbles per minute can be used, thereby reducing gas consumption and prolonging the life of the gas bottle, or reducing the duty cycle operation of the compressor pump on our HS 55/45/40/35 bubbler water level measurement systems. The main GC01P/SS chamber is constructed entirely of polyethylene with a copper coated brass screen to deter aquatic growth, and is supplied fitted with a 2" flexible stainless steel coupling to suit a standard 2 NB threaded pipe and to allow easy installation as the coupling allows up to 30 degrees of adjustment from horizontal. The GCO1P /SS has an in built 1/4 inch NPT hex brass coupling and is supplied with 1/4 inch NPT male to 3/8 inch. The bottom of the chamber includes a revolving copper coated brass screen for cleaning purposes the unit is designed to be fitted to existing installations preferably during low water condition. PERFORMANCE COMPARISON Based on 9 metres/hr of rise At 3 metres level of rise the standard orifice still lagged significantly whereas the gas chamber orifice exhibited no appreciable error. HS
35 Step 1: 2 BSP THREADED PIPE Step 2: Step 3: Gas Purge Compressor- Model HS-55/DO/DB HS Issue 2: 30/5/2014
36 Step 4: 30 Note: Ensure that the GCO1 is horizontally level as shown. Flexible coupling allows 2 Galvanised Pipe Flexible Coupling (L) GCO1 Body Volume = ml (H) Tube River Line Tube Back Front Orifice fitting Revolving Screen (for cleaning Purposes) (D) Dimension L D H GCO1P DIMENSIONSS Metric (mm) Imperial (inch) Gas Purge Compressor- Model HS-55/DO/D DB HS Issue 2: 30/ /5/2014
37 XIV APPENDIX B STANDARD ORIFICE INSTALLATION HS
38 XV APPENDIX C HS 55/DO/DB TYPICAL INSTALLATIONS HS 55 TYPICAL INSTALLATION HS
39 HS
40 HS55 DO TYPICAL INSTALLATION HS
41 HS
42 HS55 DB TYPICAL INSTALLATION HS
43 XV UPGRADING THE HS 55 DRYER/MIST SEPARATOR ASSEMBLY Note: Prior to starting disconnect the power and purge the tank. Step 1 Using a spanner undo the hose fitting (1a) and the Non Return valve fitting(1b). Once done undo the two mounting screws (1c) to remove the filter assembly. Step (1a) Step (1c) Step (1b) Step 2 The new dryer/filter kit is supplied in two sections, the first is the Dryer/Mist Separator and the second is the mist separator purge valve. HS
44 Step 3 Installation process 3b Using appropriate Allen Key loosens the two screws. Note do not fullyy undo. The purge valve bracket will be hooked to the back of the panel using the manifold screws. Once done tighten t the screws back on. 3d insert is still in position. Pull the quick release fitting back and push the tube all the way in and then release the fitting First ensuree the ¼ tube 3e Please connects your compressorr to12v power, once the tank is fully pressurised spray leak detector and check for any leaks. If no leaks are detected, your compressor is ready for use. Gas Purge Compressor- Model HS-55/DO/D DB HS a Screw the new Dryer/Mist Separator to the panel, re compressor c hose and assemble the the Non returnn valve ¼ tube. 3c shown Issue 2: 30/ Connect Wires as /5/2014
Hyquest Solutions Pty Ltd
INSTRUCTION MANUAL BUBBLERS MODELS HS23SL / HS23DL / HS23DO QUALITY SYSTEM ISO: 9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA Phone:(Int.) 612 9601 2022 Fax: :(Int.)
More informationHydrological Services Pty Ltd 2012
INSTRUCTION MANUAL DRY BUBBLE UNIT MODEL HS23SL/HS23DO HYDROLOGICAL SERVICES PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA Phone: (Int.) 612 9601 2022 Fax:(Int.) 612 9602 6971 Phone: (Nat.) (02)
More informationHS Bubbler Technology. HyQuest Solutions New Zealand User Group August 2017
HS Bubbler Technology HyQuest Solutions New Zealand User Group August 2017 Origins of Gas Purge Technology 1940 s - Developed By Dutch Engineer Late 1940 s 1954 - Adopted by State of Illinois Water Group
More informationInstallation and Operation Manual. Advanced Bubbler System
Installation and Operation Manual Advanced Bubbler System Models: HS40 Compact (HS40AFC) HS40/2100 Compact (HS40AFC/2100) HS40/3100 Compact (HS40AFC/3100) HS40/3100A Compact (HS40AFC/3100A) plus /DO and
More informationHYQUEST SOLUTIONS PTY LTD INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL TB6
INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL TB6 QUALITY SYSTEM ISO:9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA Phone:(Int.) 612 9601 2022 Fax: :(Int.)
More informationINSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE. MODEL TB3/0.1mm
INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL TB3/0.1mm QUALITY SYSTEM ISO 9001 2008 CERTIFIED HYQUEST SOLUTIONS PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA Phone:(Int.) 612 9601 2022 Fax:
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS 1NP0680 - PROPANE CONVERSION FOR USE WITH MODELS: PM8, PC8, PM9, PC9, FL9M, FL9C, FC9M, FC9C This conversion kit is to be installed by a qualified service agency
More informationModel PSI Compressor with 3-Gallon Air Tank 12VDC
Model 6350 150 PSI Compressor with 3-Gallon Air Tank 12VDC IMPORTANT: It is essential that you and any other operator of this product read and understandd the contents of this manual before installing
More informationO P E R ATING INSTRUCTIONS FOR MODEL SPR-45 Automatic Screen and Stencil Printer
O P E R ATING INSTRUCTIONS FOR MODEL SPR-45 Automatic Screen and Stencil Printer TABLE OF CONTENTS I. SPECIFICATIONS...3. II. SAFETY INSTRUCTIONS...4. III. INSTALLATION...5. IV. SET-UP...6. V. SYSTEM OPERATION...9.
More informationINSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB3
INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB3 QUALITY SYSTEM ISO:9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA Phone:(Int.) 612 9601 2022 Fax: :(Int.) 612
More informationTHE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301
THE HF-300 SERIES Operating and Service Manual Series includes all variants of HF-300/301 Issue A July 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 3.1. Spring Loaded...
More informationBUBBLER CONTROL SYSTEM
BUBBLER CONTROL SYSTEM Description: The LDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air
More informationTHE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)
THE BP-301 SERIES Operating and Service Manual Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) Issue B October 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation...
More informationBUBBLER CONTROL SYSTEM
BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete
More informationTECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY
Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry
More informationInstruction Manual Updated 7/26/2011 Ver. 2.2
4-Unit Model MB HTHP Filter Press #171-50-4: 115-Volt #171-51-4: 230-Volt Instruction Manual Updated 7/26/2011 Ver. 2.2 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele:
More informationTECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13
Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationTECHNICAL DATA. Q = C v P S
Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationTECHNICAL DATA. Trimpac 251a. Spetember 16, 2013
Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release
More informationKJ4000 Operating Instructions & Parts Manual NSN
KJ4000 Operating Instructions & Parts Manual NSN 1025-01-473-7710 Mandus Group Ltd. KJ4000 Operators Manual Date: 3 Jan. 2002 TABLE OF CONTENTS General Safety Instructions...Page 1 Operator Instructions...Page
More informationTECHNICAL DATA. Trimpac 244a. September 16, 2013
September 16, 2013 Trimpac 244a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-1 and B-1B is a factory-assembled trim package with an electric release module in a metal enclosure. The standard trim normally
More informationFOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM
IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete
More informationTECHNICAL DATA. Q= Cv S
Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry
More informationDPC-30 DPC-100. Reference Manual
DPC-30 DPC-100 Reference Manual 1. Introduction 1.1 Description The Martel DPC Digital Pneumatic Calibrator improves upon traditional dial gauge pneumatic calibrators. The Martel DPC improves accuracy,
More informationTECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE
1 of 10 1. DESCRIPTION (Refer to Figures 1-3.) Viking supervised Single Interlocked Preaction Systems utilize a Viking Deluge Valve and a pneumatically pressurized automatic sprinkler system. The system
More informationCSA Sample Draw Aspirator Adapter Operator s Manual
30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More informationSystem Pressure Manager Standard & System Pressure Manager Plus
System Pressure Manager Standard & System Pressure Manager Plus Installation, Commissioning & Servicing Instructions Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,
More information200 PSI COMPRESSORS - MODEL NUMBERS
200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read
More informationPressure Dump Valve Service Kit for Series 3000 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 000 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00, 400, 500, and 700 applicator
More informationIMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.
More informationTHE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401
THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated
More information100C Air Compressor Kit
10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is
More informationRK-IR Sample Draw Aspirator Adapter Operator s Manual
30-0951RK-IR Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0018RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment
More information420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO
420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this
More informationACCESSORY KIT INSTALLATION MANUAL
ACCESSORY KIT INSTALLATION MANUAL LP (PROPANE) CONVERSION KIT 1NP0366 FOR USE WITH MODELS: G8C & GF8 This conversion kit shall be installed by a qualified service agency in accordance with these instructions
More informationSouth-Tek Systems - Nitrogen Generation Corrosion Inhibiting System. Designed for: Dry or Preaction Fire Protection Systems (FPS)
South-Tek Systems - Nitrogen Generation Corrosion Inhibiting System Designed for: Dry or Preaction Fire Protection Systems (FPS) 1.0 Description of Work 1.1 The Fire Sprinkler Contractor shall provide
More informationBS2000 MOTOR ELECTRONICS, INC. PROTECTION INSTRUCTION MANUAL. (407) Phone: Website:
BS2000 INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: Website: (407) 299-3825 www.mpelectronics.com Revision Date: 6-23-14 RECOMMENDED REPLACEMENT
More informationUltRo Dual Flow Reverse Osmosis Water System
UltRo Dual Flow Reverse Osmosis Water System Congratulations on this great investment to your health. **IMPORTANT NOTE BEFORE YOU BEGIN** We recommend you call your local friendly plumber to ensure proper
More information250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO
250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual
More informationG96 Series BASOTROL Dual Operator Valve
Installation Instructions 9. Issue Date February 22, 2013 G96 Series BASOTROL Dual Operator Valve Applications The G96 valves are combination, dual operator, automatic valves available with or without
More informationNTF-230 OPERATION MANUAL
NTF-230 OPERATION MANUAL MAHLE Aftermarket Inc., Service Solutions 10 Innovation Drive York, Pennsylvania 17402 USA Phone: 717-840-0678 Toll Free: 800-468-2321 Web-site: www.servicesolutions.mahle.com
More informationAdditel 761 Automated Pressure Calibrators Selection Guide
Automated Calibrators Selection Guide Model Features Range 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP 0.05 to 8 bar.a -0.90 to 25 bar (1.2 to 115 psi.a) (-13 to 375 psi) 0.1 to 26 bar.a
More informationAdditel 761 Automated Pressure Calibrators
Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure
More informationAdditel 761 Automated Pressure Calibrators Selection Guide
/ Process Calibration Equipment Automated Calibrators Selection Guide Model Features Range Module 1 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP -2.5 to 2.5 mbar (-1 to 1 inh 2 O) -0.95
More informationTECHNICAL DATA. Trimpac 257a. September 16, 2013
September 16, 2013 Trimpac 257a 1. DESCrIpTION DESCRIPTION The Viking Double SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-2 and D-2B used with either a Model E or F Deluge Valve (A.1), a Viking
More informationPressure Dump Valve Service Kit for Series 2300 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit
More informationInstallation Instructions
LP and High Altitude LP Gas Conversion Kit For United States Installations Installation Instructions For Model Series *G6/PGF1 Furnaces, *L1/PGC1 Furnaces, and *R4/PPG1 Gas/Electric Appliances using Honeywell
More informationUniversal Valve Company Inc
1975-FA34 (Air Tower Troubleshooting Manual) Overview This manual has been arranged as a tool for diagnosing, and repairing Universal Air Towers Please read closely to identify the components that are
More informationOperating Procedure TITON SUBSEA BOLT TENSIONER
Operating Procedure TITON SUBSEA BOLT TENSIONER B & A Hydraulics Ltd Block 1, Units 1 & 2 Souter Head Industrial Centre Souter Head Road Altens Aberdeen Phone: 01224 898955 Fax: 01224 898787 E-Mail: TITON@bahyd.co.uk
More informationUniversal Valve Company Inc
Universal Valve Company Inc 800-223-0741 www.universalvalve.com 1975-FA34 (Air Tower Troubleshooting Manual) Overview This manual has been arranged as a tool for diagnosing, and repairing Free Air Universal
More informationTECHNICAL DATA. Trimpac 256a. October 31, 2013
October 31, 2013 Trimpac 256a 1. DESCRIPTION The Viking SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-1 and D- 1B used with either a Model E or F Deluge Valve (A.1), a Viking Easy Riser check valve
More informationNGP-250/500 Nitrogen Generator Quick Start Guide
NGP-250/500 Nitrogen Generator Quick Start Guide Version: A July 2013 Potter Electric Signal Company, LLC 5757 Phantom Dr., Suite 125 P. O. Box 42037 Hazelwood, MO 63042 Phone: (314) 595-6900 Document
More informationPremium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.
Premium Series High Quality Forged Brass Body Rust-Resistant Nickel Plated Finish Long Life Corrosion Resistant Valve Seat Economical Price & Reliable Performance Tamper-Resistant locking Screw Reduces
More informationVERTICAL BLADDER TANK
Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure
More informationSPECIFICATIONS ATTENTION
VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane
More informationTECHNICAL DATA. TRIMPAC Model B-5 & B-5B
September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on
More informationTHE HF-210 SERIES. Operating and Service Manual. Series includes all variants of HF-210/211. Issue A October 2014 *Section 6.
THE HF-210 SERIES Operating and Service Manual Series includes all variants of HF-210/211 Issue A October 2014 *Section 6.1 in development 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3.
More informationTECHNICAL DATA. Q = C v P S
Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction
More informationInstallation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units
Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure
More informationTHE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691
THE BP-690 SERIES Operating and Service Manual Series includes all variants of BP-LF/MF-690/691 Issue B April 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special
More informationTECHNICAL DATA OBSOLETE
April 9, 2009 Preaction 326a 1. DESCRIPTION Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilizing the Viking G-4000P Deluge Valve. The small profi le, lightweight,
More informationG196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve
Installation Instructions Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied
More information250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO
250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual
More informationAutoChanger Installation & User Guide Issue 2
1 INDEX Page 1. Introduction... 3 2. AutoChanger Components Guide 4 3. Installation. 5-11 a) Installation Guidelines.. 5 b) Installation Retrofit... 6-11 c) Installation New... 11 4. AutoChanger User Guide
More information444C DUAL PERFORMANCE VALUE PACK
(Chrome) PART NO. 44432 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL
More informationRD(H)20/25 Pressure-Reducing Regulator User Manual
RD(H)20/25 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be
More informationAdditel 761 Automated Pressure Calibrators
Additel 761 Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure modules Built-in
More informationDual Solenoid Gas Valve Installation
Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions
More informationATD LB PRESSURE BLASTER INSTRUCTION MANUAL
ATD-8402 90LB PRESSURE BLASTER INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS SAFETY INSTRUCTIONS FOR SANDBLASTER 1. Before opening the tank release the air pressure on the sand tank. To do this, turn off
More informationaccidents which arise due to non-observance of these instructions and the safety information herein.
3 GALLON PANCAKE COMPRESSOR Model: 50959 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated
More informationTECHNICAL DATA. System water supply pressure enters the priming chamber of the deluge valve (A.1) through the 1/4 (8 mm) priming line, which
January 27, 2012 307a 1. (Refer to Figures 1-3.) A Viking Non-Interlocked Preaction system utilizes a Viking Deluge Valve to control water flow into system piping equipped with closed sprinklers. Under
More informationCode AWC20HP Air Compressor
Code 951816 AWC20HP Air Compressor Index of Contents Index of Contents 02 Declaration of Conformity 02 What s Included 03 Safety Precautions 03 Specifications (AWC20HP Air Compressor) 04 Assembly Instructions
More informationTECHNICAL DATA CAUTION
Page 1 of 6 1. DESCRIPTION The Viking Model D-2 Accelerator is a quick-opening device, with an integral anti-flood assembly, used to increase the operating speed of a differential type dry pipe valve.
More informationInstallation and Operation Manual. Advanced Bubbler System. Models : HS40 Series II HS40/3100 Series II HS40/3100A Series II and Dual Orifice
Installation and Operation Manual Advanced Bubbler System Models : HS40 Series II HS40/3100 Series II HS40/3100A Series II and Dual Orifice Series II QUALITY SYSTEM ISO: 9001 CERTIFIED HYQUEST SOLUTIONS
More information400C & 450C DUAL PERFORMANCE VALUE PACKS
(Chrome) PART NO. 40013 (Silver) PART NO. 45012 (Chrome) PART NO. 45013 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before
More informationINSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB305-1MM
HYDROLOGICAL SEVICES PTY LTD INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB305-1MM QUALITY SYSTEM ISO 9001 2008 CERTIFIED HYDROLOGICAL SERVICES PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA
More informationG196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve
Installation Instructions Issue Date August 19, 2008 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied
More informationHORIZONTAL BLADDER TANK
Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure
More informationPANACEA P100 LOW PRESSURE USER MANUAL
Basic Features Stainless steel body with 7/8 outside diameter. Will fit into wells down to 1 (schedule 80). Uses static water pressure to fill gas and sample return tubes. Maximum depth below ground surface
More informationINSTRUCTION MANUAL. January 23, 2003, Revision 0
INSTRUCTION MANUAL Model 810A In-Vitro Test Apparatus for 310B Muscle Lever January 23, 2003, Revision 0 Copyright 2003 Aurora Scientific Inc. Aurora Scientific Inc. 360 Industrial Parkway S., Unit 4 Aurora,
More information97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO
97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and
More informationOperation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER
Operation Manual - PN 0017946001 A MENSOR MODEL 73 SHOP AIR BOOSTER Mensor Model 73 Shop Air Booster System (750 psi Version) April 23, 2012 Trademarks / Copyright Mensor is a registered trademark of Mensor
More informationair/hydraulic nut riveter heavy-duty vacuum system
instructions for air/hydraulic nut riveter heavy-duty vacuum system model no: SA317 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
More informationModel HS40V/HS40V-DO
Model HS40V/HS40V-DO Advanced Bubbler System Installation and Operation Manual HYDROLOGICAL SERVICES Pty Ltd 48-50 Scrivener Street Liverpool NSW 2170 Australia Ph. 61 2 9601 2022 Fax. 61 2 9602 6971 Internet:
More informationV43 Pressure Actuated Water Regulating Valve
FANs 125, 121 Product/Technical Bulletin V43 Issue Date 0996 V43 Pressure Actuated Water Regulating Valve The V43 Pressure Actuated Water Regulating Valves are designed to regulate water flow for water-cooled
More informationUser Manual for the Mars Calibration Bench
User Manual for the Mars Calibration Bench Fall 2013 Table of Contents Table of Contents Table of Contents... iii Introduction... v Chapter 1: The Mars Calibration Bench... 1 What Is the Mars Calibration
More informationAssembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &
REDQ Regulators Model 411B Barstock Design Powreactor Dome Regulator OPERATION AND MAINTENANCE Contents Scope..............................1 Installation..........................1 General Description....................1
More informationNatural Gas to L.P. Gas Conversion Kit
Natural Gas to L.P. Gas Conversion Kit For Bosch 80% AFUE Gas Furnace, BGS80 Model Installation Instructions 3124627 2 Natural Gas to L.P. Gas Conversion Kit Installation Instructions Data subject to change
More information36H SERIES Combination Gas Valve
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION The 36H series combination gas valve is
More informationAdditel 761 Automated Pressure Calibrators
Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure
More informationUBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions
Document Number: XE-ATA5PM-R1A UBEC 1AT AUTO TANK Fill System 08899155 Installation, Operation, & Setup Instructions Rev170906-EB-FRC PHYSICAL: 1302 WEST BEARDSLEY AVE ELKHART, IN 46514 WWW.ELKHARTBRASS.COM
More informationDiscontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.
Powers Controls RV 201 Pressure Reducing Valves Description Features Product Numbers Dual Pressure PRV Technical Instructions Document No. 155-049P25 RV 201-1 Single Pressure PRV The RV 201 Pressure Reducing
More informationLARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual
LARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual 002694 IntroductIon 8-1-11 Page 1 ForEWord This manual is intended for use with
More information400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO
400H HARDMOUNT AIR COMPRESSOR KIT PART NO. 40042 450H HARDMOUNT AIR COMPRESSOR KIT PART NO. 45042 400H 450H IMPORTANT: It is essential that you and any other operator of this product read and understand
More informationType 3 - PSA Nitrogen Generation System
Type 3 - PSA Nitrogen Generation System Designed for: Dry or Pre-Action Fire Protection Systems (FPS) with a total capacity from 6,000 to 18,000 gallons 1.0 Nitrogen Generation Corrosion Inhibiting System
More information36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve
Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION
More information