Hydrological Services Pty Ltd 2012

Size: px
Start display at page:

Download "Hydrological Services Pty Ltd 2012"

Transcription

1 INSTRUCTION MANUAL DRY BUBBLE UNIT MODEL HS23SL/HS23DO HYDROLOGICAL SERVICES PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA Phone: (Int.) Fax:(Int.) Phone: (Nat.) (02) Fax:(Nat.) (02) Web:

2 Content Content... 2 I. HYDROLOGICAL SERVICES STANDARD WARRANTY TERMS... 3 II. GENERAL... 4 III. UNPACKING YOUR HS23 BUBBLE UNIT... 4 IV. SPECIFICATION... 5 V. INSTALLATION & OPERATION OF MODEL HS VI. ADJUSTMENT OF BUBBLE RATE USING INSTRUMENT LINE... 8 VII ADJUSTMENT OF BUBBLE RATE USING RIVER LINE VIII Part List Appendix IX INSTALLATION OF POLYTHENE TUBING AND ORIFICE FITTINGS X STANDARD ORIFICE XI GAS CHAMBER ORIFICE XII TYPICAL INSTALLATION Page 2

3 I. HYDROLOGICAL SERVICES STANDARD WARRANTY TERMS WARRANTY, DISCLAIMER AND LIMITATION OF LIABILITY: We warrant this product to be free from defects in material and workmanship for a period of three years from the date of shipment hereof or its total rated life, whichever first occurs. During the warranty period, we will repair or replace this product if it is returned to us with shipping charges prepaid and we determine it to be defective. This warranty shall not apply if this product has been subjected to misuse, negligence, accidents, or misapplied, or modified or repaired by unauthorised persons, or improperly installed, and we shall not be liable to any person for personal injury or property damage caused by such a product. All other warranties, express and implied, including warranties of MERCHANTABILITY and FITNESS FOR A PARTICULAR PURPOSE, are disclaimed. All other remedies and liabilities, including incidental, consequential, and special damages, losses, and expenses, are excluded. Note: It is Hydrological Services policy to support all of our products. If design or workmanship problems arise after this statuary warranty period we request that you contact us. Page 3

4 II. GENERAL The is a gas purge system for converting water head to pressure for operation in conjunction with water level pressure sensing instruments. It provides a constant differential pressure (3-5 psi) above the pressure head at the end of the river line. This constant differential pressure maintains a constant bubble rate through the river line and enables a pressure sensing instrument to measure the change in pressure. The variation in pressure is proportional to the variation in river level. The HS-23 is a design which incorporates a regulator valve for setting the bubble rate. The unit is pre-calibrated at the factory (refer to section VII). This new design eliminates the need of sight glass and oil reservoir for the setting of the bubble rate. It also eliminates costly and often ineffective maintenance of the bubble unit due to oil inadvertently getting into the system which is the most common cause of failure with sight glass devices. The HS-23 is a low maintenance unit with minimum components ensuring increased reliability. The high quality of the construction materials ensures long life in the harshest of environments. III. UNPACKING YOUR HS23 BUBBLE UNIT This package should contain: Dry Bubble Unit Allen Key (1/32ʺ) Please verify you have received these items and that the type of dry bubble unit is as ordered. To prepare the dry bubble unit for installation: read manual carefully, it can be downloaded from our website lift the unit from the carton and place on secure surface remove polythene bag undo the two mounting bolts and remove from transport board Attach Dry Bubble unit to wall or edge of self using the two holes on the mounting plate. (It is preferable to set up the bubble unit in the vertical position) Your dry bubble unit is now ready for installation (refer to section V, page 7). Page 4

5 IV. SPECIFICATION Model Configurations: 1. Single Line Gas Purging System HS23SL: a. Inlet - to suit tubing diameters 1/4" standard 3/16" alternative 3/8" alternative b. Outlet - to suit tubing diameters 3/8" standard 3/16" alternative 1/4" alternative c. Gas supply dry nitrogen or dry air d. Packing details: Dimensions: Weight: 220mm x 220mm x 150mm 3.5 kg 2. Dual Orifice Gas Purging System HS23DO: a. Inlet - to suit tubing diameters 1/4" standard 3/16" alternative 3/8" alternative b. Outlet - to suit tubing diameters 3/8" standard 3/16" alternative 1/4" alternative c. Gas supply - dry nitrogen or dry air d. Packing details: Dimensions: Weight: 220mm x 220mmx150mm 4.5 kg Compatible Pressure Sensing Instruments: Pressure Transducers Model WL3100, WL3100/A, WL2100D Page 5

6 V. INSTALLATION & OPERATION OF MODEL HS23 Set gas bottle in convenient position and fix to wall or shelf with a bracket or chain to prevent bottle from falling over. Before fitting regulator, turn on bottle to clear dust away from the outlet (also check that bottle contains gas). Fit regulator in accordance with manufacturer's instructions. Fix bubble unit in a secure vertical position to wall or edge of shelf. Install tubing as required by site conditions. Figure 1 and Figure 2 show recommended tubing arrangements for single, dual line and dual orifice systems respectively. The inlet and outlet ports are 1/4 NPT female threads and on standard units are fitted with compression fittings for use with 3/8" OD x 1/8" ID polythene tubing for outlets and 1/4" OD nylon tubing for gas inlet. An adaptor fitting can be provided to accommodate a variety of sensors and alternative tube fittings are also available on request. Refer to appendix for suggested site arrangements. Prior to opening the gas supply valve, ensure that black valve(a) to instrument and the red purge valve (C) is shut, and that black valve (B) or (E) to the river are open. In addition, ensure that the gas supply regulator is set at 500 KPa (72 psi). This supply pressure is adequate for a change of river height of 25 Metres (80 Feet). The supply pressure to the bubble unit regulator should not exceed 1,050 kpa (150 psi) under any circumstances. Open the gas supply pressure and than open the red purge valve (C) to purge the river line for approximately 10 minutes, check orifice and ensure that gas is bubbling from the orifice After purging the river line shut the red purge valve (C) and allows the bubble rate to settle for five minutes before proceeding. The HS23 is factory set to 100 ± 10% bubbles per minutes (this rate represents approximately 27 bubbles per minutes at the river line). (Refer to fig.4a) for bubble rate selection chart. For details of bubble rate adjustments (refer to section VII). Slowly open valve (A) to instrument - instrument should now respond to pressure in system and soon record the true head over the orifice. Leak test all joints. Adjust the pressure sensing device to correspond to the head indicated by the reference gauge. Page 6

7 HS-23SL Single Line Figure 1 HS-23DO Dual Orifice Figure 2

8 VI. ADJUSTMENT OF BUBBLE RATE USING INSTRUMENT LINE Note: This option is only available if customer orders the optional kit for testing bubble rate using instrument line. 12 Minimum Bubble Rate as shown in table below Change in level Metres/Hr 8 4 HS23 with GCO1P HS23 with BU07 HS22 with Glass Site Graph showing relationship between follow rate and bubble rate for selected length of tube. Please note the bubble rate changes depending on the orifice that has been used. Figure 3

9 1. Shut river line valves (B) and (E) and ensure that the purge valve is closed. 2. Shut instrument line valves (A) 3. Place Bubble Test Orifice in a container of water 4. Connect Test Orifice Line 5. Slowly open Instrument Line 6. Note: Bubble rate may not appear immediately at test orifice. Allow sufficient time for differential regulator and HS23 to stabilise pressure in test line. This may take up to 10 minutes. Once bubble rate has stabilised check bubble and if adjustment is required, refer to the chart below. 7. After checking bubble rate turn of instrument line and disconnect test orifice line 8. Reopen instrument and river line The chart below has been prepared to show the relationship between the bubble rate at the test orifice and the equivalent rates that would be observed on a sight glass bubble unit. Once the desired bubble rate has been achieved tighten the grubscrew to lock the metering valve. Bubble rate when a Gas Chamber Orifice Model (GCO1-P) in use Bubble rate when a standard orifice model BU07 in use Bubble rate when a HS22 bubble unit with sight glass is in use Note: Bubble rates detailed above are only an approximate guide for the purpose of conserving gas and have no influence on the performance of the transducer. Example: To adjust the HS23 to the equivalent of 120 bubbles per minute, the metering valve should be rotated anticlockwise until 35 bubbles per minute are emerging from the test orifice of the bubble unit. Page 9

10 VII ADJUSTMENT OF BUBBLE RATE USING RIVER LINE 12 Minimum Bubble Rate as shown in table below Change in level Metres/Hr 8 4 HS23 with GCO1P HS23 with BU07 HS22 with Glass Site Graph showing relationship between follow rate and bubble rate for selected length of tube. Please note the bubble rate changes depending on the orifice that has been used. Figure 4

11 The HS23 Bubble Unit has been factory set to the equivalent rate of 100 bubbles per minute. To check and adjust the bubble rate the following method should be employed: 1. Shut the instrument line valve (A), river line valves (B) and (E) and ensure that the purge valve is closed. 2. Disconnect the river line tubing from the bubble unit. 3. Connect a one metre length of tube to the river line fitting of the bubble unit. 4. Submerge the other end of the tube to a depth of 100mm in a container of clean water. (This end of the tube should be secured at this depth, preferably in a horizontal position). The end of the tube should not be in contact with the sides or bottom of the water container. 5. The water container should be placed on a steady surface to prevent movement of the water. Ensure that the level of the water is below the level of the HS23 bubble unit, to avoid the ingress of water. 6. Ensure that the gas supply valve is open and the gas supply regulator is set at 500KPa. 7. Open the river line valve (B) or (E). (Gas should be bubbling from the orifice) 8. Allow the rate to settle for five minutes before timing the bubble rate. 9. With the aid of a stop watch, count the number of bubbles emerging from the orifice in a one minute period. The factory set rate is 27 +/-10% bubbles per minute. 10. For recommended bubble rates (refer to figure 4). 11. To adjust the rate, release the grubscrew in the metering valve knob. (a 1/32" Allen key will be required.) The valve is now free to rotate. 12. Rotate the valve knob to adjust the rate of bubbles emerging from the tube orifice. Clockwise to reduce and anticlockwise to increase to the desired rate. Repeat step 8 and 9 until desired bubble rate is obtained. 13. Tighten the grubscrew in the metering valve knob. (a 1/32" Allen key will be required.) The valve is now shut. 14. Shut the instrument line valve (A), river line valves (B) and (E) and ensure that the purge valve is closed. 15. Disconnect the one metre length tube from the river line fitting of the bubble unit. 16. Reconnect the river line tubing to the bubble unit 17. To continue installation (refer to section V) Page 11

12 The chart below has been prepared to show the relationship between the bubble rate at the test orifice and the equivalent rates that would be observed on a sight glass bubble unit. Bubble rate when a Gas Chamber Orfice Model (GCO1-P) in use Bubble rate when a standard orifice model BU07 or test orifice in use Bubble rate when a HS22 bubble unit with sight glass is in use Once the desired bubble rate has been achieved tighten the grubscrew to lock the metering valve. Note: Bubble rates detailed above are only an approximate guide for the purpose of conserving gas and have no influence on the performance of the transducer. Example: To adjust the HS23 to the equivalent of 120 bubbles per minute, the metering valve should be rotated anticlockwise until 35 bubbles per minute are emerging from the test orifice of the bubble unit. Page 12

13 VIII Part List Part No. BU02-04 Diaphragm Spring Part No. BU02-02 Bonnet Part No. SC Nut Aluminium-1/4 Part No. SC Nylon Ferrule-1/4 Part No. SC Metering Valve Part No. SC Screw Part No. BU04 Assembly Diaphragm Part No. HS Valve Stem Part No. SC O ring Part No. HS Retainer Nut Part No. SC Nut Brass ¼ Part No. SC Nylon Ferrule Set ¼ Part No. SC O ring Part No. SC Adaptor Tube Part No. HS Locking Screw Part No. HS Unit Body Part No. SC ¼ Tube Part No. HS ¼ Tube insert C Part No. SC Stop Valve Part No. SC ¼ Tube Part No. HS ¼ Tube insert Part No. SC Red Knob Part No. HS Manifold Part No. SC Nut Brass ¼ Part No. HSF02-01 Connector M x¼ Tube A B Part No. HSF02-01 Connector M x¼ Tube Part No. SC Nylon Ferrule Set ¼ Part No. HSF02-04 Connector F x 1/4 Tube Part No. HSF02-02 Connector F x 3/8 Tube Part No. SC Stop Valve Part No. SC Black Knob Part No. SC Nut Brass 3/8 Part No. SC Nylon Ferrule Set 3/8 Single Line Bubble Unit Model HS-23SL

14 Please Note: for the rest of the parts. Please refer to HS23-SL Part No. HSF02-01 Connector M x¼ Tube Part No. BU01-08 Cross Piece F x F x F x F C B Part No. HSF02-02 Connector F x 3/8 Tube E A Part No. HSF02-04 Connector F x 1/4 Tube Part No. SC Nut Brass 3/8 Part No. SC Nylon Ferrule Set 3/8 Part No. SC Brass Plug Part No. SC Nut Brass ¼ Part No. SC Nylon Ferrule Set ¼ Dual Orifice Bubble Unit Model HS-23DO

15 Please Note: for the rest of the parts. Please refer to HS23-SL Please Note: This product is no longer available; it has been superseded by the GCO1-P Part No. HSF02-01 Connector M x¼ Tube Part No. BU01-08 Cross Piece F x F x F x F C A D Part No. SC Nut Brass ¼ Part No. SC Nylon Ferrule Set ¼ Part No. HSF02-04 Connector F x 1/4 Tube Part No. SC Connector M x3/8 Tube Part No. SC Brass Plug Part No. SC Nut Brass 3/8 Part No. SC Nylon Ferrule Set 3/8 Dual Line Bubble Unit Model HS-23DL B Part No. HSF02-02 Connector F x 3/8 Tube Part No. SC Nut Brass 3/8 Part No. SC Nylon Ferrule Set 3/8

16 Appendix Page 16

17 IX INSTALLATION OF POLYTHENE TUBING AND ORIFICE FITTINGS A. General The polythene tubing - SC is provided in three hundred metre rolls. It is an extremely durable material that has been used successfully in this application world wide for many years. The tubing is flexible, easy to handle and can be cut with a knife. The orifice fitting is comprised of a moulded polythene threaded cap, an orifice outlet and a tube fitting. The moulded cap will screw onto a standard 50 nominal bore galvanised pipe. B. Orifice Fittings The site and reference level for the orifice fittings should be resolved before installation proceeds. The length of tubing from the HS23 to the orifice should not exceed 150 metres. A suggested method for installation of the orifice fitting is shown below. The site of the orifice should be positioned in quiet water out of the mainstream to provide protection. The area should be free of silting and aquatic growth. The mounting for the orifice fitting should consist of a section of 50 nominal bore galvanised pipe threaded at one end and secured at the appropriate reference level. The securing of the orifice mounting should be such that it can withstand the forces applied by the flowing stream and associated floating debris. C. Preparation of Orifice Tubing Do not open the carton or remove the strapping. To prepare the roll of tubing for use, cut a 300 mm diameter hole in the centre of the cardboard carton, retrieve the end of the tubing from the middle of the coil, then cut the strapping retaining the coil. This method will reduce the possibility of tangling the tubing. Prevent the ingress of dirt etc. from entering the tubing, by taping up the ends. At no time should the open end of the tubing be permitted to contact the soil. D. Orifice Tubing It is recommended that a trench be dug (minimum 600 deep) between the equipment shelter and the proposed positions of the orifice The trenches should not have any low points in their length; they should have a continuous fall to the river. Page 17

18 Pull the free end of the coiled tubing to the orifice position laying the tubing in the trench as you go. Refer to diagrams below Remove the protective tape from the end of the tubing, and push the tubing through the 50 nominal bore pipe mounting. Insert the tubing into the tube fitting on the rear of the orifice fitting, ensuring that both ferrules are in place. Tighten the fitting nut. (Refer to the following diagram for tightening procedure). Place the orifice fitting onto the mounting pipe and tighten. Cut the tube at the coil end (tape both ends), ensuring that there is sufficient length to make the joint at the HS23 within the shelter. Check the lay of the tubing in the trench to ensure that it is free of coils and kinks. Under no circumstances should the tube form hollows where moisture can be trapped within the tube. Lay the tubing into position in the equipment shelter as required. Remove the protective tape from the end of river line tube. Insert the end of the tube into the appropriate river line fitting on the HS23 and tighten both fittings. (Refer to diagram for tightening procedure). Open the valve to the orifice. Page 18

19 X STANDARD ORIFICE Page 19

20 XI GAS CHAMBER ORIFICE The Hydrological Services Gas Chamber Orifice (GCO1-P) is designed to replace the standard orifice in a gas purge water level measurement system The GCO1 permits the use of extremely low bubble rates with increased sensitivity and near total reduction of lag between actual level rise and orifice pressure. It can also operate satisfactorily when buried under up to 1m of silt. Bubble rates as low as 10 bubbles per minute can be used, thereby reducing gas consumption and prolonging the life of the gas bottle, or reducing the duty cycle operation of the compressor pump on our HS-55/45/40 bubbler water level measurement systems. The main GC01-P chamber is constructed entirely of polyethylene with a copper coated brass screen to deter aquatic growth, and is supplied fitted with a 2" flexible coupling to suit a standard 2 threaded pipe and to allow easy installation as the coupling allows up to 30 degrees of adjustment from horizontal. The GCO1-P has an in-built 1/4 inch NPT hex brass coupling and is supplied with 1/4 inch NPT male to 3/8. The bottom of the chamber includes a revolving copper coated brass screen for cleaning purposes The unit is designed to be fitted to existing installations preferably during low water condition. Refer reverse side for results of comparative tests and installation details. Float Operated Encoder (Level in mm) Standard Orifice 100 Bubbles/Min Gas Chamber Orifice 10 Bubbles/Min Reading Lag Reading Lag Page 20

21 Step 1: Secure Socket/Locknut to the 2 BSP pipe 2 BSP THREADED PIPE Step 2: Undo the nut and ferrules; feed the tube nut and the two ferrules onto the river line as shown in figure below Step 3: Tighten the tube nut to the GCO1 fitting as shown in figure below

22 Step 4: Place the GCO1 assembly onto the mounting pipe, adjust coupling so the GCO1 is horizontal to the water, and tighten the flexible coupling with GCO1 in position. 30 O Note: Ensure that the GCO1-P is horizontally level as shown. Flexible coupling allows adjustment up to 30 degrees. Parts & Dimensions

23 XII TYPICAL INSTALLATION

Hyquest Solutions Pty Ltd

Hyquest Solutions Pty Ltd INSTRUCTION MANUAL BUBBLERS MODELS HS23SL / HS23DL / HS23DO QUALITY SYSTEM ISO: 9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA Phone:(Int.) 612 9601 2022 Fax: :(Int.)

More information

HyQuest Solutions Pty. Ltd.

HyQuest Solutions Pty. Ltd. INSTRUCTION MANUAL L GAS PURGE COMPRESSOR MODEL HS55V / HS55VDO/HS55VB Gas Purge Compressor- Model HS-55/DO/D DB HS-55 100-1 Issue 2: 30/5/2014 CONTENTS Contents HS 55 & HS 55DO & HS 55DB GAS PURGE COMPRESSOR...

More information

INSTRUCTION MANUAL TIPPING BUCKET RAINGUAGE MODEL TB3

INSTRUCTION MANUAL TIPPING BUCKET RAINGUAGE MODEL TB3 HYDROLOGICAL SEVICES INSTRUCTION MANUAL TIPPING BUCKET RAINGUAGE MODEL TB3 QUALITY SYSTEM ISO 9001 2000 CERTIFIED HYDROLOGICAL SERVICES PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA Phone:(Int.)

More information

HS Bubbler Technology. HyQuest Solutions New Zealand User Group August 2017

HS Bubbler Technology. HyQuest Solutions New Zealand User Group August 2017 HS Bubbler Technology HyQuest Solutions New Zealand User Group August 2017 Origins of Gas Purge Technology 1940 s - Developed By Dutch Engineer Late 1940 s 1954 - Adopted by State of Illinois Water Group

More information

Model No Product Name Handpiece Only Complete System

Model No Product Name Handpiece Only Complete System Ney QC 700 E 30,000 RPM IECE 30,000 R N HANDPIE IVEN HA R DRIV AIR D Owner & Operator's Manual Model No Product Name 7201326 Handpiece Only 7201325 Complete System Description Page Safety... 2 Setup...

More information

HYQUEST SOLUTIONS PTY LTD INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL TB6

HYQUEST SOLUTIONS PTY LTD INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL TB6 INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL TB6 QUALITY SYSTEM ISO:9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA Phone:(Int.) 612 9601 2022 Fax: :(Int.)

More information

Installation and Operation Manual. Advanced Bubbler System

Installation and Operation Manual. Advanced Bubbler System Installation and Operation Manual Advanced Bubbler System Models: HS40 Compact (HS40AFC) HS40/2100 Compact (HS40AFC/2100) HS40/3100 Compact (HS40AFC/3100) HS40/3100A Compact (HS40AFC/3100A) plus /DO and

More information

Halsey Taylor Owners Manual STOP!

Halsey Taylor Owners Manual STOP! Halsey Taylor Owners Manual 4710 Freeze Resistant Floor Mounted Steel Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4710FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY

More information

INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB305-1MM

INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB305-1MM HYDROLOGICAL SEVICES PTY LTD INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB305-1MM QUALITY SYSTEM ISO 9001 2008 CERTIFIED HYDROLOGICAL SERVICES PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA

More information

D Series Air and Water Kit Part# 02550

D Series Air and Water Kit Part# 02550 D Series Air and Water Kit Part# 02550 Unpacking Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you undamaged.

More information

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4410FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY ARE LOCATED

More information

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com

More information

CSA Sample Draw Aspirator Adapter Operator s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual 30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

KJ4000 Operating Instructions & Parts Manual NSN

KJ4000 Operating Instructions & Parts Manual NSN KJ4000 Operating Instructions & Parts Manual NSN 1025-01-473-7710 Mandus Group Ltd. KJ4000 Operators Manual Date: 3 Jan. 2002 TABLE OF CONTENTS General Safety Instructions...Page 1 Operator Instructions...Page

More information

RK-IR Sample Draw Aspirator Adapter Operator s Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual 30-0951RK-IR Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0018RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP LIMITED WARRANTY Getz Equipment Innovators warrants its products, and component parts of any product manufactured by

More information

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401 THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special

More information

INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE. MODEL TB3/0.1mm

INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE. MODEL TB3/0.1mm INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL TB3/0.1mm QUALITY SYSTEM ISO 9001 2008 CERTIFIED HYQUEST SOLUTIONS PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA Phone:(Int.) 612 9601 2022 Fax:

More information

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301 THE HF-300 SERIES Operating and Service Manual Series includes all variants of HF-300/301 Issue A July 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 3.1. Spring Loaded...

More information

J Air and Water Kit Instructions Part# 02584

J Air and Water Kit Instructions Part# 02584 J Air and Water Kit Instructions Part# 02584 Unpacking Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you

More information

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010 LUDLUM MODEL 239-1F FLOOR MONITOR Revised LUDLUM MEASUREMENTS, INC. 501 OAK ST., P.O. BOX 810 SWEETWATER, TX 79556 325/235-5494 FAX: 325/235-4672 STATEMENT OF WARRANTY Ludlum Measurements, Inc. warrants

More information

453 Series Steam Heated Vaporizing Regulator

453 Series Steam Heated Vaporizing Regulator ADI 0453A Certified ISO 9001:2000 453 Series Steam Heated Vaporizing Regulator INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls Corporation

More information

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS 18 GAUGE 1-1/4 INCH BRAD NAILER Model: 7611 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.

More information

INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB3

INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB3 INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB3 QUALITY SYSTEM ISO:9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA Phone:(Int.) 612 9601 2022 Fax: :(Int.) 612

More information

RD(H)20/25 Pressure-Reducing Regulator User Manual

RD(H)20/25 Pressure-Reducing Regulator User Manual RD(H)20/25 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be

More information

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual 8 Executive Drive P.O. Box 2105 Toms River, NJ 08754 (732) 244-0010 (800) 337-3762 fax (732) 244-8140 www.permapure.com info@permapure.com

More information

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS 18 GAUGE 2 INCH BRAD NAILER Model: 7555 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.

More information

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

PRESSURE COMPARATOR 10000PSI 700bar. Operator Instructions CRYSTAL. engineering corporation

PRESSURE COMPARATOR 10000PSI 700bar. Operator Instructions CRYSTAL. engineering corporation PRESSURE COMPARATOR GauGeCaLXP 10000PSI 700bar Operator Instructions Page 2 GaugeCalXP Operator Instructions PRESSURE is Our BUSINESS Introduction Thank you for purchasing a GaugeCalXP Pressure tor from

More information

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual ATD-31166 3/8 x 50 Retractable Air Hose Reel Owner s Manual Features Heavy-gauge, all-steel reel assembly 8-position ratchet mechanism locks reel at desired hose length 5-position adjustable roller outlet

More information

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings Installation Instructions V48 Issue Date 08/30/01 V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings Application IMPORTANT: The V48 Series 3-Way Pressure-Actuated Water-Regulating

More information

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings Installation Instructions V46 Issue Date 11//1 V46 Series -Way Pressure-Actuated Water-Regulating Valves With Union Fittings Application IMPORTANT: The V46 Series -Way Pressure-Actuated Water-Regulating

More information

HYDROLOGICAL SERVICES INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB4

HYDROLOGICAL SERVICES INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB4 HYDROLOGIAL SERVIES INSTRUTION MANUAL TIPPING BUKET RAINGAUGE MODEL TB4 QUALITY SYSTEM ISO 9001 2008 ERTIFIED HYDROLOGIAL SERVIES PTY LTD PO BOX 332, LIVERPOOL B. NSW 1871, AUSTRALIA Phone:(Int.) 612 9601

More information

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY

More information

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com P5523 Liquid to Gas Separator Users Manual PN 3952355 November 2010 2010 Fluke Corporation. All rights

More information

RK LEL Sample Draw Aspirator Adapter Operator s Manual

RK LEL Sample Draw Aspirator Adapter Operator s Manual 30-0951RK LEL Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0017RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

V43 Pressure Actuated Water Regulating Valve

V43 Pressure Actuated Water Regulating Valve FANs 125, 121 Product/Technical Bulletin V43 Issue Date 0996 V43 Pressure Actuated Water Regulating Valve The V43 Pressure Actuated Water Regulating Valves are designed to regulate water flow for water-cooled

More information

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691 THE BP-690 SERIES Operating and Service Manual Series includes all variants of BP-LF/MF-690/691 Issue B April 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special

More information

Techcon Systems TS1254 Pressure Pot

Techcon Systems TS1254 Pressure Pot Techcon Systems TS1254 Pressure Pot User Guide Copyright OK International, Inc. TABLE OF CONTENT 1. SAFETY. 3 1.1 Intended Use 3 1.2 Safety Precaution 3 2. FEATURES. 5 3. SPECIFICATIONS 4 4. INSTALLATION

More information

ROPV R40 E Series User Manual

ROPV R40 E Series User Manual HARBIN ROPV INDUSTRY DEVELOPMENT CENTER ROPV R40 E Series User Manual For Use with the Following ROPV Pressure Vessel Models: R40 300E R40 450E Headquarters Tel:(+86)451-82267301 Fax:(+86)451-82267303

More information

VERTICAL BLADDER TANK

VERTICAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware 57007-88 Introduction Safety Precautions This instruction sheet describes how to set up and use the Hach (Figure 1). A water weir is a device that raises or diverts water to regulate the flow. Hach s water

More information

Interface Devices, Inc. Hydraulic Mini Mule

Interface Devices, Inc. Hydraulic Mini Mule Interface Devices, Inc. Hydraulic Mini Mule INSTALLATION, OPERATION & MAINTENANCE MANUAL IMPORTANT! FILE THIS MANUAL IN A SAFE PLACE FOR FUTURE SERVICE & PARTS NEEDS ALWAYS REFERENCE THE SERIAL NUMBER

More information

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , & REDQ Regulators Model 411B Barstock Design Powreactor Dome Regulator OPERATION AND MAINTENANCE Contents Scope..............................1 Installation..........................1 General Description....................1

More information

FLANGED MULTI-PORT BALL VALVES

FLANGED MULTI-PORT BALL VALVES INTRODUCTION This instruction manual includes installation, operation and maintenance information for flanged multi-port ball valves. This manual addresses lever operated ball valves only. Please refer

More information

Yoke Block Instruction Manual

Yoke Block Instruction Manual Yoke Block Instruction Manual ! WARNING IMPORTANT: READ MANUAL COMPLETELY BEFORE OPERATING THIS DEVICE This manual contains instructions on periodically required checks to be performed by the user. These

More information

HORIZONTAL BLADDER TANK

HORIZONTAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

Instruction Manual Updated 7/26/2011 Ver. 2.2

Instruction Manual Updated 7/26/2011 Ver. 2.2 4-Unit Model MB HTHP Filter Press #171-50-4: 115-Volt #171-51-4: 230-Volt Instruction Manual Updated 7/26/2011 Ver. 2.2 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele:

More information

PENBERTHY SUBMERSIBLE AUTOMATIC SUMP DRAINER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

PENBERTHY SUBMERSIBLE AUTOMATIC SUMP DRAINER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Before installation, these instructions must be read carefully and understood. PRODUCT WARRANTY Emerson warrants its Penberthy products as designed and manufactured to be free of defects in the material

More information

1200B2 Series Service Regulators. Instruction Manual

1200B2 Series Service Regulators. Instruction Manual 00B Series Service Regulators Instruction Manual 00B Series Service Regulators 0 Elster American Meter 00B Series Service Regulators General Information The 00B Series Service Regulators are available

More information

FLANGED TWO-PIECE BALL VALVES

FLANGED TWO-PIECE BALL VALVES INTRODUCTION This instruction manual includes installation, operation, and maintenance information for FNW flanged split-body ball valves. This manual addresses lever operated ball valves only. Please

More information

Dual Solenoid Gas Valve Installation

Dual Solenoid Gas Valve Installation Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions

More information

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1. 2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or

More information

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015)

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015) CHEMICAL INDUCTION KIT (Pt.No.2400-0740 Issue 6, October 2015) DESCRIPTION The C-Dax Chemical Induction Kit is an accessory kit for the GoldLine range of three point linkage sprayers. The system operates

More information

Techcon Systems TS1258 Pressure Pot

Techcon Systems TS1258 Pressure Pot Techcon Systems TS1258 Pressure Pot User Guide TABLE OF CONTENT 1. SAFETY. 3 1.1 Intended Use 3 1.2 Safety Precaution 3 2. CERTIFICATE OF COMFORMANCE 4 3. FEATURES. 5 4. SPECIFICATIONS 5 5. INSTALLATION

More information

GILMONT ACCUCAL FLOWMETERS

GILMONT ACCUCAL FLOWMETERS OPERATING MANUAL GILMONT ACCUCAL FLOWMETERS 28W092 Commercial Ave. Barrington, IL U.S.A. 60010-2392 (847) 381-4888 (847) 381-7053 (Fax) 800-962-7142 www.barnant.com e-mail: barnant@barnant.com A-1299-0766

More information

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series Introduction Powerex manifolds are cleaned, tested and prepared for the indicated gas service and are built in accordance with the Compressed Gas Association guidelines. The manifold consists of a regulator

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

FLANGED TWO-PIECE BALL VALVES

FLANGED TWO-PIECE BALL VALVES INTRODUCTION This instruction manual includes installation, operation, and maintenance information for FNW flanged split-body ball valves. This manual addresses lever operated ball valves only. Please

More information

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-15 OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE

More information

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual TOP VALVE Pat. #5,857,486 & 5,944,050 High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves Instruction Manual PLEASE NOTE: This instruction manual provides information and instructions

More information

1800C and 1800C-HC Series Service Regulators

1800C and 1800C-HC Series Service Regulators 1800C and 1800C-HC Series Service Regulators Installation Instructions www.elster-americanmeter.com General Information: The 1800C and 1800C-HC Regulators are available as Full Capacity Internal Relief

More information

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor M A R T E C H S E R V I C E S C O M P A N Y P.O. Box 7079 OFFICE: (507)

More information

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES INSTRUCTION MANUAL Installation Operation Parts Service IMPORTANT Record your Regulator model number and serial number here for easy reference: Model No. Serial No. Date of Purchase When ordering parts

More information

Model ASSEMBLY and OPERATING INSTRUCTIONS

Model ASSEMBLY and OPERATING INSTRUCTIONS QUICK CHANGE AIR BRUSH KIT Model 93506 ASSEMBLY and OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd.,

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for the installation, operation, and

More information

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013 Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release

More information

OWNER S MANUAL. This manual contains; IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS MAINTENANCE FACTORY SERVICE REPAIR PARTS WARRANTY

OWNER S MANUAL. This manual contains; IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS MAINTENANCE FACTORY SERVICE REPAIR PARTS WARRANTY OWNER S MANUAL This manual contains; IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS MAINTENANCE FACTORY SERVICE REPAIR PARTS WARRANTY Models covered; PA506 EL506 Ergonomic Tool Arms, LLC PO Box

More information

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation, Operation and Maintenance Manual for Back Pressure Regulator Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN

More information

Regulator from 1800 B series

Regulator from 1800 B series Regulator from 1800 B series Regulator from 1800 B series Measuring of industrial gases frequently requests a precise pressure regulation for the purpose of dosage and proccesing. UNIS FAGAS has two kinds

More information

Masoneilan* 78 Model Air Filter Regulator

Masoneilan* 78 Model Air Filter Regulator GE Oil & Gas Masoneilan* 78 Model Air Filter Regulator Instruction Manual [Rev. D] GE Data Classification : Public THESE INSTRUCTIONS PROVIDE THE CUSTOMER/OPERATOR WITH IMPORTANT PROJECT-SPECIFIC REFERENCE

More information

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) THE BP-301 SERIES Operating and Service Manual Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) Issue B October 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation...

More information

Model Series 62 Constant Differential Relay

Model Series 62 Constant Differential Relay Siemens Industry, Inc. INSTALLATION AND SERVICE INSTRUCTION INTRODUCTION Model Series 62 Constant Differential Relay Rev 11 March 2011 Supersedes Rev 10 The Constant Differential Relay maintains a constant

More information

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235) P/N 126905-01 Rev. B 11/2016 INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235) For All Single, Dual and Triple Burner Natural and Propane/LP Gas Logs P126905-01 For

More information

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Page 1 of 20 Page 2 of 20 TABLE OF CONTENTS Safety Warnings

More information

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number 3M Water Filtration Products FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number 56123-06 Installer: Please leave this manual with owner/operator. End User: Please retain for

More information

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA. Trimpac 244a. September 16, 2013 September 16, 2013 Trimpac 244a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-1 and B-1B is a factory-assembled trim package with an electric release module in a metal enclosure. The standard trim normally

More information

FRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System

FRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System FRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System For inflating aircraft tires and all types of other vehicle tires and air operated devices Manual The Steelebrook Group Where Imagination

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Instrument Supply Pressure System Model WIC The information in this manual has been carefully checked for accuracy and is intended to be used as a

More information

PRO-50 Instrument Supply Regulator

PRO-50 Instrument Supply Regulator Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits

More information

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP 50-24 General User and Maintenance Instructions Silentaire Technology 8614 Veterans Memorial Dr. Houston, TX 77088 800-972-7668 Fax 832-327-0669 www.silentaire.com

More information

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator. RHPS Series RD(H)F40 User Manual Read the complete manual before installing and using the regulator. 2 WARNING Before removing a regulator from the system for service, you must depressurize system purge

More information

600 / 600FC OWNER'S MANUAL

600 / 600FC OWNER'S MANUAL PROGRESSION 600 / 600FC OWNER'S MANUAL Issue 2 / Version E - Dec. 10, 1997 Copyright 1997 GAMMA Sports - All Rights Reserved PROGRESSION 600 / 600FC OWNER'S MANUAL TABLE OF CONTENTS PAGE 1... WARRANTY

More information

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves. Powers Controls RV 201 Pressure Reducing Valves Description Features Product Numbers Dual Pressure PRV Technical Instructions Document No. 155-049P25 RV 201-1 Single Pressure PRV The RV 201 Pressure Reducing

More information

User Instruction Manual

User Instruction Manual User Instruction Manual 4500 psi Air Compressor Ver 2, 1.18 Contents Parts Included...3 Assembly Instructions...3-5 Operation Instructions...6-7 Oil Change Intervals...8 Air Filter Replacement...9 Setting

More information

Manual. FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator. Where Imagination Meets Innovation

Manual. FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator. Where Imagination Meets Innovation FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator For inflating aircraft tires and all types of other vehicle tires and air operated devices Manual The Fresh Aero Group Where Imagination Meets

More information

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

3 UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC. 3" UC-3000 (76.2 mm) Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual DOUBLE E COMPANY, INC. 319 Manley Street, West Bridgewater, MA 02379 U.S.A. Tel: (508) 588-8099 /

More information

Adjustable. Unloader Valve. O&M Manual. Part #

Adjustable. Unloader Valve. O&M Manual. Part # Adjustable Unloader Valve O&M Manual Unloader Valve Part #60-020-361 ADVANCED PRESSURE SYSTEMS 701 S. Persimmon St., Suite 85 - Tomball, TX 77375 Toll Free in North America: (877) 290-4277 Phone: (281)

More information

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS 262-2040 Hot Tapping Machine For performing 1/4 6 Hot taps 285 psi or less. Municipal Water, Sewage, & Building Services Use OPERATIONS MANUAL and OPERATING INSTRUCTIONS WARNING: These instructions are

More information

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on

More information

G7S Hand Pump Owner s Manual

G7S Hand Pump Owner s Manual G7S Hand Pump Owner s Manual Copyright Air Venturi 2018 Version 4-18 Specifications 24.80 inches long closed 43.31 inches long extended 4500 psi/310 bar max pressure Features Integral manometer (pressure

More information

Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Dump Valve Service Kit for Series 2300 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit

More information

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic

More information

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual ! WARNING IMPORTANT: READ MANUAL COMPLETELY BEFORE OPERATING THIS DEVICE This manual contains instructions on periodically required checks to be

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information SIX R431006322 (P -063892-00001) AND SEVEN R431006321 (P -063981--00002) POSITION CYLINDERS Service Information The six and seven position cylinders are medium duty pneumatic positioning devices that operate

More information

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger) IB-77 Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger) These installation, operation and technical instructions should be used by experienced personnel as a

More information

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual TOP VALVE Pat. #5,857,486 & 5,944,050 Mid-Range Pressure 50 232 PSIG Back Pressure and Pressure Relief Valves Instruction Manual Please Note: This instruction manual provides detailed information and instructions

More information

602 STRINGING MACHINE OWNER'S MANUAL

602 STRINGING MACHINE OWNER'S MANUAL PROGRESSION 602 STRINGING MACHINE OWNER'S MANUAL AL Issue 1- April 2000 Copyright 2000 GAMMA Sports - All Rights Reserved PROGRESSION 602 STRINGING MACHINE TABLE OF CONTENTS PAGE 1... WARRANTY PAGE 2...

More information

92831 TEL: (714) FAX:

92831 TEL: (714) FAX: Document N0. 1800-03 Copyright 2010 Terra Universal Inc. All rights reserved. Revised Sept. 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX:

More information