EC-064.indd /12/21 16:16:52

Similar documents
SP/ST/SA Models Pulse-input and Analog-input Control

High precision dispensing valve that is an uncompromising response to the need for sophisticated dispensing equipment

Integral type Differential pressure flowmeter VNT Series

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

OWNER S TECHNICAL MANUAL

SM Models Manual Control

TH-1800-T TRX-700-CNG Converter

SM Models Manual Control

Digital Flow Switch. Series PFM7

Qi Litre Ultrasonic Cleaner

ACV-10 Automatic Control Valve

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Pneumatic high-pressure controller Model CPC7000

Booster Regulator/Air Tank

ELADOS EDP L Diaphragm Metering Pump Type

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

INSTALLATION & MAINTENANCE INSTRUCTIONS

VACUUM REGULATORS CONTENTS

Design Features. General Description

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Visualize Nitrogen Gas Consumption

BUBBLER CONTROL SYSTEM

Variable Area Flow Meters

BUBBLER CONTROL SYSTEM

Expert Hydrostatic Level Transmitters

Precision Regulator. Series Model Regulating pressure range Port size Page

The Univentor 1250 Anaesthesia Unit

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

LEWA ecoflow. Diaphragm metering pumps and process diaphragm pumps. accurate safe economical innovative

ROYTRONIC EXCEL TM Series AD Electronic Metering Pumps

Pneumatic high-pressure controller Model CPC7000

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Process Pump. Self-priming makes priming unnecessary. Air operated type. Air supply port. 5 port solenoid valves. Application Example

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

P499 Heavy Duty Pressure Transducer

DTG - LCD Digital Temperature Gauge USER MANUAL

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

THE UNIVENTOR 400 ANAESTHESIA UNIT

Measurement of Low GAS & Liquid Flows

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

628 Differential Pressure Decay Leak Tester

HumiSys HF High Flow RH Generator

Electro-Pneumatic Converter YT-940 SERIES

Model 130M Pneumatic Controller

Technical Data Sheet MF010-O-LC

Variable Area Flow Meters

TECHNOLOGIES. M Series. Positive return metering pumps [API675]

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

[Instruments for vacuum measurement, checking and adjustment] 3

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Glass tube flowmeters Series 2000

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

INSTRUCTION MANUAL. process. Ultrasonic Flowmeter Range

Differential Pressure Transmiter

ID-Cube. Installation and Operations Manual For ID-Cube Source and Power Supply. Revision 2 Document #:

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Constant Pressure Inlet (CCN) Operator Manual

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

VACCUPERM Vacuum chlorine gas dosing systems

Aquavar SOLO 2 Frequently Asked Questions

Quick Installation Guide Doc nr.: C Date:

Columbus Instruments

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Pressure Measurement Single-range transmitters for general applications

Air Saving Valve. Pressure Valve Flow Valve

EXH. Specifications. Descriptions. Min. working pressure MPa

MICRO DIAPHRAGM GAS PUMPS

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

MPM426W/436W Submersible Level Transmitter

MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

RP series Rotor Pumps

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

ALF400 to 900, ALT-5/-9

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

TECHNICAL ACCESSORIES

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Direct Operated Precision Regulator Modular Style. Standard Specifications

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

MODEL HICV-130Ti7-331N. Lot NAGOYA JAPAN PAT.

RG2 Gripper Datasheet Version 1.6

Inverse Proportional Pressure-Relief Cart., Size 2 4

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Pressure Relief Valve DHV 718

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

Smart performance with innovative and ever-strong coil drive even under harsh working environments

VERSION 1 SUMP PUMP PIT UNIT KAWAMOTO PUMP ASIA CO.,LTD.

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Transcription:

www.tacmina.com

All-New Precision Pumps for Minute Amounts World-First Mechanism Patented For Those Who Want Total Control over Liquid Flow Smoothflow --- the ideal method of liquid transfer. This innovative method not only meets your liquid transfer needs, but also provides optimal solutions to people, liquids and the environment as well. TACMINA's Smoothflow technology, based on unique know-how cultivated over 5 years, delivers you ultimate performance and provides complete satisfaction. Constant & Stable Flow Ideal Method of Liquid Transfer Eco-Friendly Economical Gentle on Liquids

Are you and your conventional laboratory pump plagued with problems like these? Tube type Low accuracy and reduced flow rate The structure of conventional pumps makes strict flow control difficult. Over time, tube elasticity decreases, making it impossible to achieve original flow rates. High running costs Special tubes for organic solvents in particular wear out quickly, and components are generally expensive, leading to higher running costs. Syringe type Continuous, long-term liquid transfer is impossible Multi-type apparatuses are required for continuous transferring of liquids beyond the capacity of the syringe. Pulsation arises when switching from one syringe to the next. Scaling up is difficult Revalidation using pumps from another system is necessary when transitioning to actual production. Plunger type Severe wear Plunger wear leads to decreases in performance and improper discharges. Abration debris can mix into the liquid, contributing to contamination. Liquid leakage Liquid can begin to leak from the seals. This can be problematic with dangerous chemicals and liquids that solidify or deteriorate when exposed to air. Diaphragm type (Single pump head) Excessive pulsation Reciprocating pumps cause intermittent flow with pulsations, requiring installation of a pulsation damper. With a Smoothflow Pump, such problems are a thing of the past.

Pumping performance and reliability that exceeds conventional laboratory pump's limitations Smoothflow Pumps designed for state-of-the-art manufacturing processes requiring extremely high precision, including applications for thin film coating and pharmaceutical manufacturing. The Q Series is the first pump that brings TACMINA's Smoothflow technology to the laboratory. Excellent quantitative performance and responsiveness TACMINA pumps provide impressive quantitative performance with repeatability within ±1% (full scale ratio). Flow rates can be finely configured at units of.1 ml/min. In addition, the excellent responsiveness allows for quick enforcement of starting and stopping s and flow rate change s. Watch sample transfer videos. Pumping demo Flow rate change Auto-stop In-line mixing Four types selectable according to flow rate and discharge pressure Model Q-1 Flow rate.1 to 1mL/min Max. discharge pressure.3mpa Q-6 Q-3 Q-1.1 to 6mL/min.1 to 3mL/min.1 to 1mL/min.6MPa 1.MPa 2.MPa Ability to maintain pumping accuracy over long periods of time Since there are no sliding parts, the load applied to the liquid-end section is small, preventing component wear and decreases in flow rate even over long-term use. In other words, the service life of the components is longer and running costs are low. Flow rate (ml/min) 1 8 6 4 2 Changes in flow rate over continuous No decrease in flow rate even after more than 5 hours of Test conditions: Fresh water at room temperature with a discharge pressure of.3 MPa 1 2 3 4 5 Operation time (h)

Continuous, constant flow with no pulsation Conventional pumps TACMINA's proprietary pumping mechanism (patented) enables pulsation-free, continuous, constant flow even with diaphragm pumps. Injection fluctuation Uniform No liquid leakage or changes in properties Since no sliding parts are used, localized pressure does not change, liquid is not altered by frictional heat, and solidification is prevented. The completely sealed structure also features no mechanical seals, eliminating the need to worry about liquid leakage. Delicate liquids that may be altered if exposed to air can also be conveyed with no changes to the liquid properties. Conventional pumps Air intrusion or Liquid leakage No intrusion of air Completely sealed Not damaged by clogged piping or dry running No load is applied to the pump even when the pump is obstructed, such as when the valve fails to open or clogging occurs, so there's no need to worry about malfunctions. The absence of sliding parts means there's no need to worry about galling, seizing, wear, or damage even with dry running. With increased pressure Pumping is stopped to protect the pump Also supports autoclave sterilization A model whose entire liquid-end section can be sterilized with an autoclave is also available.

Simple, user-oriented design for ease of use Easy setting and calibration Users can change the flow rate just by entering the desired rate. Pump calibration can also be performed just by measuring and inputting the actual discharge rate. This allows for easy and accurate flow control. Simple disassembly and assembly The liquid-end section can be disassembled just by removing the bolts. Since assembly can be performed without trouble even for the first time, anyone can assemble the pump and maintain original performability. Easy liquid change With a spare pump head set, the liquid can be switched quickly just by replacing the pump head. Users can also use pump heads for fluids requiring the use of different head materials.

I/O control, gradient and other various functions Auto-stop Operation times and discharge amounts can be set to stop pump automatically. Q Signal output function QIQT Signals can be output for use with external equipment. Example 1 Stopping the pump after pumping for 2 hours Example 2 Stopping the pump after pumping 5 ml 5 Unit pulse Alarm Operation signal Stop end signal Pulse signal output after a specific amount is discharged Signal output when an error occurs Signal output while the pump is in Pulse signal output when interval or gradient ends (QT only) Pulse-input proportional Pumps can be operated automatically depending on a pulse signal input from an external device. QI Analog-input proportional The flow rate can be changed automatically relative to an analog signal (4 to 2 ma DC) input from an external device. QI Example 1 1 ml discharged at 5 ml/min per pulse signal Example 2 1 ml discharged at 25 ml/min per pulse signal Example 1 Flow rate control between and 5 ml/min for signals between 4 and 2 ma Example 2 Flow rate control between 1 and ml/min for signals between 4 and 12 ma Pulse signal ON OFF Pulse signal ON OFF 1 1 5 5 5 5 25 25 2 min. 2 min. 4 min. 4 min. 4 12 2 Analog signal (ma) 4 12 2 Analog signal (ma) Interval QT Pump can be turned ON and OFF at regular intervals repeatedly. Gradient QT The flow rate of a pump can be gradually increased or decreased in proportion to how much operating time has passed. Example 1 Operation at a flow rate of 5 ml/min starting after 3 minutes and stopping after 2 minutes performed repeatedly 5 Continuation Example 2 Operation at a flow rate of 5 ml/min starting after 2 minutes and stopping after 2 minutes performed 3 times and then stopped 5 End Example 1 After 2 minutes of at 2 ml/min, flow rate increased to 8 ml/min over 6 minutes with 2 minutes of at 8 ml/min 1 5 Example 2 Gradient with positive symmetry using 2 linked pumps (constant total flow rate) 1 5 A+B Liquid A Liquid B 3 min. 2 min. 2 min. 2 min. 2 min. 6 min. 2 min. 2 min. 6 min. 2 min.

Application Examples Continuous over extended periods Long-term continuous is possible for durability tests. Thanks to a structure that incorporates no sliding parts for transferring, the flow rate does not decrease due to wear or the like even over long periods. Control types: Q, QI, QT Functions: Manual Dispensing Operation automatically stops following discharge of a specified amount of liquid. This functionality is useful when collecting a fixed amount of a liquid. Control types: Q, QT Functions: Auto-stop or interval Constant-cycle injection Operation can be performed and stopped at a constant cycle. Regular injection s can be performed automatically and with no user input. Control types: QT Functions: Interval Gradient mixing Static mixer Liquid A Liquid B When two or more pumps are linked together, mixing can be performed while gradually changing the ratio of liquids. (Consult TACMINA for applications requiring six or more pumps.) Signal wire Control types: QT Functions: Gradient

Flow-proportional injection Flow meter In accordance with the flow rate in the main piping being measured by the flow meter, the amount of chemical to be injected can be adjusted automatically by inputting a signal to the pump. Control types: QI Signal cable Functions: Pulse or analog-input proportional [Tip] Control proportional to a liquid's chemical concentration, ph value, or temperature is also possible. Linked transfer of multiple liquids Liquid A Liquid B Liquid C The transfer amounts of multiple pumps can be linked by outputting a unit pulse for each constant discharge rate and then inputting that pulse to another pump. For example, this functionality makes it possible to control the pumps so that 5 ml of liquid B is injected for every 1 ml of liquid A that is injected. Signal cable Signal cable Control types: QI Functions: Unit pulse signal output and pulse-input proportional Program control Using commercially available system development software allows for complex flow control that suits the desired purpose. D/A converter Control types: QI Functions: Analog-input proportional

Model Selection Guide Model code *1 Control type Model (flow rate standard) Liquid-end material Power plug Language General specifications *1 If manufactured with special specifications, this will be "X". Select control type. Name (Standard type) (I/O signal control type) (Timer control type) Operation panel Operation mode Manual Calibration Auto-stop Manual Calibration Analog-input proportional Pulse-input proportional Manual Calibration Interval Gradient Select model (flow rate standard). Name 1 6 3 1 Flow rate.1 to 1mL/min.1 to 6mL/min.1 to 3mL/min.1 to 1mL/min Maximum discharge pressure.3mpa.6mpa 1.MPa 2.MPa Select liquid-end material. Name Shape *1 *1 *1 A type that supports autoclave sterilization is also available. Pump head PVC PVC PTFE SUS316 Diaphragm PTFE/CR PTFE/CR PTFE/CR PTFE/CR Sheet valve and packing EPDM Special fluoro rubber Special fluoro rubber (perfluoro[ffkm]) Special fluoro rubber (perfluoro[ffkm]) Joint PP PP PTFE SUS316 Contact TACMINA for details. *1 This can only be selected for the Q-1. It cannot be selected for the Q-6, Q-3, or Q-1. Select power plug. Name ULP AUP EUP UKP JPL Shape UL plug Australia plug EU plug (CE) UK plug (CE) Lead wire

MANUAL CAL AUTO STOP ACT DIR MANUAL CAL ACT DIR AUTO STOP MAX CANCEL ml/min ml L sec min ml/min ml L sec min MANUAL CAL ACT DIR AUTO STOP START MAX MODE CANCEL STOP ml/min ml L sec min SET Specifications Pump specifications Model Q / QI / QT Specifications 1 6 3 1 ml/min 1 6 3 1 Maximum flow rate *1 L/h 6 3.6 1.8.6 US G/h 1.58.95.47.15 Flow rate control range Variable from.1 to the maximum flow rate MPa.3.6 1 2 Maximum discharge pressure bar psi 3 43.5 6 87 1 145 2 29 Reproducibility ± 1% (F.S.) Connection diameter 4 6 Ambient temperature to 4 *2 Transfer liquid temperature Rated voltage 1 to 24VAC ± 1% Power supply Phase/frequency 1 / 5 Hz or 6 Hz Cord 2 m *4 *5 Weight kg *6 VE / VF: 1.6, TT: 1.7, 6T: 2.5 *1 Conditions: Clean water at room temperature. *2-1 to 5 C during transportation and storage. *3 Contact TACMINA for the conditions. *4 The weight of the stand is excluded.*5 This is the weight of the Q (standard type). *6 This is the weight of the Q-1. The Q-6/3 is 2.6 kg. The Q-1 is 2.9 kg. Control functions to 4 (no freezing) to 6 for the Q-1-6T depending on the conditions (no freezing) *3 Transfer liquid viscosity mpas 2 or less 1 or less Environmental resistance IEC standard: Corresponds to IP65 (dust proofing and waterproofing) Accessories Tube (4 6) 2m * VE / VF: Polyolefin resin, TT / 6T: PTFE Syringe (24mL) 1 Nonslip sheet 1 External dimensions Main unit 11 MAX MODE CANCEL MODE SET START STOP SET START STOP 95.6 128.1 32.5 23.5 18 Pump stand set 1 set * A pump stand with machine screws Mounting bolt set 4 sets * Hexagon bolts and nuts Operation manual 1 (B) A C Q-1 Q-6 Q-3 Q-1 VEVFTT 6T 6T A 26 26 22 B 191 187 187 184 19 C 137.1 137.1 137.1 134.4 139.9 When attached to the stand 131 65.5 65.5 Function Manual Auto-stop Pulse-input proportional Analog-input proportional Interval Gradient Description Setting possible in units of.1 ml/min or.1 ml/min Operating time: 1 to 9999 seconds or 1 to 9999 minutes Discharge volume:.1 to 999.9 ml or.1 to 999.9 L.1 to 999.9 ml/pulse or.1 to 999.9 L/pulse Controllable according to set target value (SV) and max. flow rate (HV) Flow:.1 ml to MAX (.1 ml units) ON time / OFF time: 1 to 9999 seconds or 1 to 9999 minutes Flow:.1 ml to MAX (.1 ml units) Time: 1 to 9999 seconds or 1 to 9999 minutes (Initial retention time, gradient time, final retention time) Q QI QT 142 2 5 145.6 55 R3 6 A Q-1 Q-6 Q-3 Q-1 VEVFTT 6T 6T 6T 6T A 179.1 175.1 175.1 172.4 177.9 I/O signal specifications (QI and QT only) Consumables (per pump) Signal Analog Digital Input Input Output QI 1 port 4 to 2mADC Input resistance: Approximately 11Ω 2 ports No-voltage contact or open collector Maximum pulse count: 6pulses/min Minimum pulse width: 5msec (ON time) Assigned to one of the following: Pulse, pause/run, level, or MAX 2 ports 25VDC, 1mA or less Assigned to one of the following: Unit pulse, alarm, or signal QT 2 ports No-voltage contact or open collector Maximum pulse count: 6pulses/min Minimum pulse width: 5msec (ON time) Assigned to one of the following: Start, pause/run, level, or MAX 2 ports 25VDC, 1mA or less Assigned to one of the following: Unit pulse, end signal, alarm, or signal Part name Quantity Recommended replacement interval Diaphragm 2 Sheet valve 1 4, hours or 1 year Packing 1 Protective sheet 1 When deterioration or damage is visible

The next level of Smoothflow Pumps for applications that call for more performance Scaling up Achieve flow rates of up to 3 L/min and discharge pressures as high as 1.5 MPa. Slurries and high-viscosity liquids Get smooth, trouble-free transfers of abrasive slurries and liquids with high viscosities up to 2 mpa s. Explosion proof Take advantage of the optional explosion-proof motor (d2g4). Sanitary Sanitary types are also available for food, medicine, fine chemicals, and other applications. The same excellent precision and ease of use as the Q Series! Continuous, constant flow with no pulsation Excellent quantitative performance Manual flow rate Easy disassembly and maintenance PVC, PTFE and SST liquid-end parts Performance specifications Model 1 3 1 3 1 3 ml/min 9 25 1 3 1 3 Max. discharge volume L/h.54 1.5 6 18 6 18 US G/h.14.39 1.58 4.75 15.84 47.52 MPa 1.5 1.5 1. 1..5.5 Max. discharge pressure bar 15 15 1 1 5 5 psi 217.5 217.5 145 145 72.5 72.5 Other Smoothflow Pumps Max. discharge volume: 3 L/min Max. discharge pressure: 15 MPa Ultra high-precision pump to meet the needs of tomorrow. Max. discharge volume: 45 L/min Max. discharge pressure:.5 MPa Large-capacity specification for sanitary use. Transfer slurries and high-viscosity liquids. Smoothflow System Combine pumps, tanks, and control devices in order to design and manufacture equipment and systems that suit your needs. Max. discharge volume: 3 L/min Max. discharge pressure: 5 MPa Customizable design allows for handling of a variety of applications. Max. discharge volume: 8 L/min Max. discharge pressure: 1 MPa Simple structure with outstanding cost performance. EC-64(3)- 217/12/D--