Clean Air Filter Built-in Hollow Fiber Element

Similar documents
Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Clean Air Filter Built-in Hollow Fibre Element

Vacuum / Release Unit

Clean Gas Filter. SF Series. Cartridge Type/Disposable Type IDFA IDFB IDH ID IDG IDK AMG AFF AM AMD AMH AME AMF ZFC SF SFD LLB AD GD SFC10

Related Products: Auto Drain Valve. Model/Specifications. Model

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

Series IRV1000/2000/3000

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

Series ZFC. Air Suction Filter. In-line Type with One-touch Fittings

PRODUCT NAME. Main Line Filter. MODEL / Series / Product Number

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Pilot Check Valve: Metal Body Type

30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

Series AMJ. Drain Separator for Vacuum

kpa or less 5.0. Compressed Air Preparation Filter. AFF/AM/AMD Series CAT.ES30-17B. 1 μm (Current model: 3 μm) 20% 60% 52% 160 mm.

Industrial Filter. FGD series

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Air operated valve. VGA342R Series

Doc. No.SYJ300-OMO0002-A. Air Operated Valve PRODUCT NAME. SYJA300 / SYJ3000 Series MODEL/ Series

INSTALLATION & MAINTENANCE INSTRUCTIONS

CAT.ES60-17 A. Compact Electro-pneumatic Regulator. Series ITV0000. Compact and lightweight electro-pneumatic regulator

Filter-Regulator-Lubricator

Operation Manual Air Saver Unit ASV5000 Series

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Clean Air Filter Built-in Hollow Fibre Element

PVC Quick Drain Valve

Clean Speed Controller with One-touch Fitting

Coiling Tube with Twist-Proof Fitting

IR1000-A IR1010-A IR1020-A

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Compressed Air Cleaning Filter Series

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Direct Operated Precision Regulator Modular Style. Standard Specifications

Compressed Air Cleaning Filter Series

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Filter-Regulator-Lubricator

5.0 MPa Maximum Supply Pressure. New. Stepless control of air pressure proportional to an electrical signal. Series ITVX CAT.

Process Pump. Self-priming makes priming unnecessary. Air operated type. Air supply port. 5 port solenoid valves. Application Example

Clean Regulator/Fluororesin Type

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

F.R.L. Units Precautions 1 Be sure to read this before handling.

5 Port Air Operated Valve

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

reduces flow setting time and setting errors!

Booster Regulator/Air Tank

Moisture Control Tube

Push-In Fitting Type Silencer

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

Membrane Air Dryer. IDG1-C06 Series IDG1-C06-P Series

Port size. Model Screw-in ZFA10 1/8 ZFA20 1/4 ZFB10 ZFB20 ZFB30 ZFB40 ZFC5 ZFC7

Power Valve: Precision Regulator. High precision, large capacity relief regulator

THE WORLD COMPETITIVENESS SCOREBOARD 2011

Suitable for Semi-Conductor, Measuring Instrument, Printing and Medical Industries

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

Push-In Fitting Type Pressure Gauge

VACUUM REGULATORS CONTENTS

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.

Low torque Metal seal type Rotary joint

Precision Regulator. Series Model Regulating pressure range Port size Page

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

AMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life

Air preparation filter

Process Pump. Series PAF3000/Series PAF5000

F.R.L. Units Precautions 1 Be sure to read this before handling products.

Booster Regulator/Air Tank Increase factory air pressure by up to twice as much! Air-only operation requires no power supply, reduces

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Relays/Valves. Lock-Up Valve. Series IL201/211/220 EMC.IL A-UK

Regulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount)

Masoneilan* 78 Model Air Filter Regulator

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range.

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

ALF400 to 900, ALT-5/-9

Lightweight and Compact Type Floating Joint

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Tube Cutter with Measuring tape built-in

Pressure Gauge Series

Push-In Fitting Type with Stop Valve

Precision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.

Process Pump PB1000A

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Low Friction Cylinders

Filter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size.

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using

For Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor

Static dissipative Resin (Surface Resistivity : 10 4 ~10 7 Ω).

Doc. No.VFR3000-OMH0005-B. 5 Port Air Operated Valve PRODUCT NAME. VFRA3000, 4000 Series MODEL/ Series

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

EXH. Specifications. Descriptions. Min. working pressure MPa

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

Anti-spatter Tube. Spatter-Proof Tube for Pneumatic Piping. Polyamide type Tube Coated with Flame-Retardant Resin(Equivalent to V-0 )

Transcription:

Clean Air Filter Built-in Hollow Fiber Element Nominal filtration rating: 0.0 µm (filtration efficiency 99.99%) Initial pressure drop: 0.03 MPa (at inlet pressure 0.7 MPa, maximum flow) Maximum operating pressure:.0 MPa (at 0 C) SFD00 Up to 00 l/min SFD00 Up to 500 l/min SFD0/0 Made to Order Up to 00 l/min Restriction of Hazardous Substances RoHS compliant Series SFD CAT.ES0-5A

Clear resin case Easy to confirm a dirty element. Polycarbonated material is resistant to alcohol-based cleaning solutions. Two types of piping ports are available: clean one-touch fitting and female-threaded pipe fitting Replacement element SFD00 Can be disassembled. (Cartridge type) Replaceable hollow fiber elements Made to Order Stainless steel or aluminum cases are available. Metal case suitable for an atmosphere exposed to organic solvents and chemicals (Fluids: Air and (Nitrogen)) SFD00 SFD00 SFD0 SFD0 Type Flow rate l/min (ANR) (at inlet pressure 0.7 MPa) Port size One-touch fitting Female thread Disposable type (non-replaceable element) Up to 60 Up to 80 Up to 00 ø4 ø6 ø8 Rc /4, G /4 NPT /4 Up to 300 ø8 Up to 400 ø0 Cartridge type (replaceable element) Up to 500 ø Rc /4, G /4 NPT /4 Case material Fluid Nominal filtration rating Resin Resin Air (Nitrogen) 0.0 µm (filtration efficiency: 99.99%) Note) Aluminum Initial pressure drop Maximum operating pressure Operating temperature 0.03 MPa (at inlet pressure 0.7 MPa, maximum flow).0 MPa (in case of nitrogen: 0.99 MPa) 5 to 45 C Note) The clean air filter is designed for the filtration of solid objects. It is not suitable for the separation of water and oil. Made to Order Up to 00 Rc /4, G /4, NPT /4 Stainless steel Features

Integrated production in a clean environment Under a clean environment, all components have undergone ultrasonic cleaning. Assembly, inspection and antistatic double packaging processes are conducted in an integrated production system. Quality Control At the time of shipment, the SFD series clean air filter is 00% inspected. Shipping inspection Purification test Airtight test Assembly environment Clean room : M5.5 (ISO class 7) Clean bench: M3.5 (ISO class 5) Fed. Std. 09E ( ): based on ISO4644-. Application Examples Clean blow Protection of precision equipment Substitution of chamber Fluid pumping, etc. When blowing, take care not to entrain ambient air which could contaminate the workpieces. Circuit Examples Air source After-cooler Refrigerated air dryer Heatless air dryer or Membrane air dryer Super mist separator Fluid Clean blow Air tank Main line filter Mist separator Micro mist separator Odor removal filter Pumping the cleaning solvents Air micro meter Static paint The equipment mounted to the secondary side of SFD should be cleaned by flushing and have the same level of cleanliness as SFD. Paint + Hollow fiber membrane The hollow fiber membrane has a porous construction with numerous fine holes on a straw type fiber membrane wall. These fine holes are distributed in layers, and the layers are overlapped between the external face and internal face of the membrane. The hollow fiber membrane filter traps and filtrates the impurities from the compressed air through the overlapping layered fine holes. Filter (Image) Impurities (Image) Features

Series SFD Model Selection Select the model by using the following procedures involving the inlet pressure and the maximum flow rate. [Example] Inlet pressure: 0.6 MPa Maximum flow rate: 00 l/min (ANR). Obtain the intersection A for the inlet pressure and the maximum flow rate by using the maximum flow rate chart.. If the obtained intersection A is above the maximum flow rate line, the SFD00-C, - 0, -C0, or -C08 are selected. Note) Please be sure to select a model which is above the obtained intersection A. If the obtained intersection A is below the maximum flow rate line, overflow will occur. This will cause a nonconformance in which the specification will not be satisfied. Maximum Flow Rate 000 SFD00-C, - 0 SFD00-C0 SFD00-C08 Flow rate (l/min) 00 SFD00-C08, - 0 A SFD00-04 SFD00-06 0 0 0.5 Pressure (MPa) Front matter

Clean Air Filter Series SFD How to Order Clean air filter SFD 0 0 C08 Symbol Relationship between Operating Temperature and Max. Operating Pressure Size Max. flow rate 00 l/min (ANR) 500 l/min (ANR) Case material Symbol Material 0 Resin Aluminum Stainless steel Symbol and are made to order. For details, refer to page 5. Specifications Port size Symbol C04 C06 C08 C0 C 0 N0 F0 Option Symbol Nil B Option None (SFD00 only) The brackets are provided with the SFD00 series as a standard product. (Nil) ø4 ø6 ø8 ø0 ø Connection size Clean one-touch fitting (KP series) Rc /4 NPT /4 G /4 Note SFD00 only SFD00/00 SFD00 only Female thread SFD00/00 Different diameters for IN and OUT ports are made to order. For details, refer to page 6. Max. operating pressure (MPa)..0 0.8 0.6 0.4 0. 0 0 0 0 30 40 50 Operating temperature ( C) Model Port size Fluid Air flow capacity Nominal filtration rating Note ) Max. operating pressure Note ) Operating temperature Initial pressure drop Element proof differential pressure Note 3) Proof pressure Element service life SFD0 One-touch fitting ø4, ø6, ø8 Rc, NPT, G /4 Air (Nitrogen) Up to 00 l/min (ANR) SFD0 One-touch fitting ø8, ø0, ø Rc, NPT, G /4 Air (Nitrogen) Up to 500 l/min (ANR) 0.0 µm (99.99%).0 MPa (in case of nitrogen: 0.99 MPa) 5 to 45 C 0.03 MPa (at inlet pressure 0.7 MPa, maximum flow) 0.5 MPa.5 MPa year, or when the pressure drop reaches 0. MPa. Note ) Measured under SMC s specified conditions. Note ) The maximum operating pressure is at 0 C. For other temperatures, refer to the figure on the left (relationship between the operating temperature and maximum operating pressure). Note 3) This means that the element does not break at 0.5 MPa. See Specific Product Precautions. Model Port size Rated flow (l/min (ANR)) Note) Weight ø4 (One-touch fitting) 60 35 g SFD00 ø6 (One-touch fitting) 80 35 g ø8 (One-touch fitting) 00 35 g SFD0 SFD0 Rc, NPT, G /4 Rc, NPT, G /4 Rc, NPT, G /4 ø8 (One-touch fitting) 00 00 00 300 35 g 60 g 50 g 90 g SFD00 ø0 (One-touch fitting) 400 90 g ø (One-touch fitting) 500 90 g Rc, NPT, G /4 500 60 g Note) The maximum flow rate when the inlet pressure is 0.7 MPa.

Series SFD Flow Characteristics SFD00-C04 0.04 SFD00-C08 0.04 0. MPa 0.3 MPa 0.5 MPa 0.7 MPa 0. MPa 0.3 MPa 0.5 MPa 0.7 MPa Pressure drop (MPa) 0.03 0.0 0.0 Max. flow rate line 0.9 MPa Pressure drop (MPa) 0.03 0.0 0.0 Max. flow rate line 0.9 MPa 0 0 0 40 60 Flow rate (l/min (ANR)) 0.00 0 00 00 300 400 Flow rate (l/min (ANR)) SFD00-C06 0.04 0. MPa 0.3 MPa 0.5 MPa 0.7 MPa SFD00-C0 0.04 0. MPa 0.3 MPa 0.5 MPa 0.7 MPa Pressure drop (MPa) 0.03 0.0 0.0 Max. flow rate line 0.9 MPa Pressure loss (MPa) 0.03 0.0 0.0 Max. flow rate line 0.9 MPa 0 0 0 40 60 80 00 Flow rate (l/min (ANR)) 0 0 00 00 300 400 500 Flow rate (l/min (ANR)) SFD00-C08, -0, -N0, -F0 0.04 0. MPa 0.3 MPa 0.5 MPa 0.7 MPa SFD00-C, -0, -N0, -F0 0.04 0. MPa 0.3 MPa 0.5 MPa 0.7 MPa Pressure drop (MPa) 0.03 0.0 0.0 Max. flow rate line 0.9 MPa Pressure loss (MPa) 0.03 0.0 0.0 Max. flow rate line 0.9 MPa 0 0 0 40 60 80 00 0 Flow rate (l/min (ANR)) 0 0 00 00 300 400 500 600 Flow rate (l/min (ANR))

Clean Air Filter Series SFD Construction SFD00-C tyui r q w SFD00-0 SFD00-C!!4 rtyu i e r q w e o q! w!0!3 e Component Parts No. Description Material Note 3 4 5 6 7 8 Element Cover O-ring Seal Cushion Stopper Cassette Case: Clear resin Resin Resin Replacement Parts No. Description Part no. Note set SFD-BR00 Component Parts No. Description Material Note 3 4 5 6 7 8 9 0 3 4 Element Cover Fitting body Seal Cushion Stopper Cassette O-ring A O-ring B Rod cover Tie-rod Cap nut Plain washer Case: Clear resin Aluminum alloy Resin General type steel General type steel Nickel plated Nickel plated Replacement Parts With countersunk head screws (M3) Component Parts No. Description Material Note 3 4 Element Cover O-ring Case: Clear resin Resin Resin Replacement Parts No. Description Part no. Note set SFD-BR00 With countersunk head screws (M3) No. Description Part no. Note Element set SFD-EL00 With 3 O-rings SFD00-0!0 i t q u w e r y o Component Parts No. Description Material Note 3 4 5 6 7 8 9 0 Element Cover Fitting body O-ring A O-ring B Rod cover Tie-rod Cap nut Plain washer Case: Clear resin Aluminum alloy General type steel General type steel Nickel plated Nickel plated Replacement Parts No. Description Part no. Note Element set SFD-EL00 With 3 O-rings 3

Series SFD Dimensions SFD00-C SMC ø3 3 6 SFD00-C Dimensions Model A C04 4 SFD00- C06 6 C08 8 B 83 83 84 mounting dimensions 4 SFD00-0 ø3 Hole shape for bracket mounting SMC 3 6 5 7 7 7 5 SFD00-C SFD00-C Dimensions Model A B SFD00- C08 C0 C 8 0 7 8 8 mounting dimensions SFD00-0 SMC 4 6 5 5 7 B 7 7 Applicable tubing O.D. øa ø3.5 90.5 3 Use a countersunk head screw (M3) for bracket mounting. SMC 4 4 96.5 4.5 B 36 Applicable tubing O.D. øa 4 x 3.5 4 4 x 7 8 03.5 96.5 4.5 9 36 4

Series SFD Made to Order Contact us for detailed specifications, delivery and prices. Metal Case Clean air filter Symbol SFD 0 Size Max. flow rate 00 l/min (ANR) The SFD is not applicable. Case material Symbol Material Aluminum Stainless steel 0 Port size Symbol 0 N0 F0 Connection size Rc /4 NPT /4 G /4 The metal case is not available with a clean one-touch fitting. The bracket is provided as a standard product. Metal case suitable for an atmosphere exposed to organic solvents and chemicals Specifications The specifications are the same as the standard product. Refer to Specifications on page. Flow Characteristics The flow characteristics are the same as the SFD00-0. Refer to Flow Characteristics on page. Construction SFD0-0 SFD0-0 q e r w q e r t w Component Parts No. Description Material Note 3 4 Case Cover Element O-ring Aluminum alloy Aluminum alloy Case: Clear resin Replacement Parts No. Description Part no. Note Element set SFD-EL0 SFD-BR0 With O-ring Component Parts No. Description Material Note 3 4 5 Case Cover Element Hex. socket head set screw O-ring Case: Clear resin Replacement Parts No. Description Part no. Note Element set SFD-EL0 SFD-BR0 With O-ring Dimensions SFD0-0 5 66 9 SFD0-0 5 66 9 ø4 ø4 50 40 50 40 3 x ø4.5 3 x ø4.5 5

Series SFD Made to Order Contact us for detailed specifications, delivery and prices. Different Diameters for IN and OUT Ports Symbol Clean air filter Size Max. flow rate 00 l/min (ANR) 500 l/min (ANR) SFD 00 C04 C06 Case material Symbol Material 0 Resin Option Symbol Nil B Option None (SFD00 only) The brackets are provided with the SFD00 series as a standard product. (Nil) IN side connection symbol IN side connection symbol C04 C06 C08 C0 C 0 N0 F0 ø4 ø6 ø8 ø0 ø Connection size Clean one-touch fitting (KP series) Rc /4 NPT /4 G /4 SFD00 Different Diameter Combinations OUT port size C04 C06 C08 0 N0 F0 C04 C06 C08 0 N0 F0 The symbol stands for unavailable combination. IN port size OUT side connection symbol OUT side connection symbol C04 C06 C08 C0 C 0 N0 F0 IN/OUT combination is the below table. IN port size ø4 ø6 ø8 ø0 ø Connection size Clean one-touch fitting (KP series) Rc /4 NPT /4 G /4 SFD00 Different Diameter Combinations OUT port size C08 C0 C 0 N0 F0 C08 C0 C 0 N0 F0 The symbol stands for unavailable combination. Specifications The specifications are the same as the standard models. Refer to Specifications on page. Flow Characteristics When the IN and OUT ports have different diameters, the flow characteristics will be those of the port with the smaller diameter. Refer to Flow Characteristics for the smaller diameter from the chart of standard product on page. Construction The construction and materials are the same as the standard product. Refer to Construction on page 3. Dimensions SFD00 different diameters SFD00 different diameters One-touch fitting dimensions Port size q ø4 Port size w One-touch fitting dimensions Port size q ø8 Port size w 5.5 SMC 6.5 ø6 5.5 Basic dimension 7 Fitting dimension A Fitting dimension B ø0 6.5 Basic dimension 4.5 Fitting Fitting dimension A dimension B ø8 ø 6 6.5 6 Model Port size q C04 (C06) C04 ( 0) C06 (C08) C06 ( 0) C08 ( 0) Port size w C06 (C04) 0 (C04) C08 (C06) 0 (C06) 0 (C08) Total length 83 (A + 7 + B) 77.5 (7 + A) 83.5 (A + 7 + B) 77.5 (7 + A) 78 (7 + A) Model SFD00- SFD00- Port size q C08 (C0) C08 ( 0) C0 (C) C0 ( 0) C ( 0) Port size w C0 (C08) 0 (C08) C (C0) 0 (C0) 0 (C) Total length 7.5 (A + 4.5 + B) (4.5 + A) 7.5 (A + 4.5 + B) (4.5 + A) (4.5 + A)

Related Products <Pre-filters for Series SFD > For details, refer to Best Pneumatics 004 Vol. 4 catalog. Mist Separator Series AM Series AM Model Rated flow (l/min (ANR)) Port size (Nominal size B) AM50 300 /8, /4 3/8 AM50 750 /4, 3/8 / Specifications Fluid Max. operating pressure Min. operating pressure Note) Proof pressure Ambient temperature Nominal filtration rating Compressed air.0 MPa 0.05 MPa 5 MPa 5 to 60 C 0.3 µm (95% particle size collection) Note) With auto drain: 0. MPa (N.O. type), 0.5 MPa (N.C. type) Micro Mist Separator Series AMD Series AMD Model Rated flow (l/min (ANR)) Port size (Nominal size B) AMD50 00 /8, /4, 3/8 3/8 AMD50 500 /4, 3/8, 3/4 / Specifications Fluid Max. operating pressure Min. operating pressure Note) Proof pressure Ambient temperature Nominal filtration rating Compressed air.0 MPa 0.05 MPa 5 MPa 5 to 60 C 0.0 µm (95% particle size collection) Note) With auto drain: 0. MPa (N.O. type), 0.5 MPa (N.C. type) Super Mist Separator Series AME Series AME Model Rated flow (l/min (ANR)) Port size (Nominal size B) AME50 00 /8, /4, 3/8 3/8 AME50 500 /4, 3/8, 3/4 / Specifications Fluid Max. operating pressure Min. operating pressure Proof pressure Ambient temperature Nominal filtration rating Compressed air.0 MPa 0.05 MPa 5 MPa 5 to 60 C 0.0 µm (95% particle size collection) Odor Removal Filter Series AMF Series AMF Model Rated flow (l/min (ANR)) Port size (Nominal size B) AMF50 00 /8, /4, 3/8 3/8 AMF50 500 /4, 3/8, 3/4 / Specifications Fluid Max. operating pressure Min. operating pressure Proof pressure Ambient temperature Nominal filtration rating Compressed air.0 MPa 0.05 MPa 5 MPa 5 to 60 C 0.0 µm (95% particle size collection) 7

Related Products Ionizer Series IZS3 Controlled ion balance by sensor Rapid elimination of static electricity by a feedback sensor Ion balance control by an autobalance sensor Ionizer Ionizer model IZS3- (NPN spec.) IZS3- P (PNP spec.) Ion generation method Method of applying voltage Output for emitting electricity Ion balance Note ) Fluid Corona discharge type Sensing DC, Pulse DC, DC ±7000 V ±30 V (in the case of stainless steel electrode needle ±00 V) Air (clean and dry) Air purge Operating pressure Connecting tubing O.D. 0.7 MPa or less ø4 Electrode needle material Tungsten, Silicon, Stainless steel Note ) In case where air purge is performed between a charged object and an ionizer at a distance of 300 mm. Note ) When measuring the potential of a charged object with a feedback sensor, the relationship between measured charge potential and sensor monitor output voltage and the sensor detecting range will differ according to the sensor installation distance. Feedback sensor Autobalance sensor Electrode Cartridge Number, Weight Bar length (mm) Electrode cartridge number Weight (g) 300 380 60 780 00 60 500 900 300 3 4 7 9 3 5 8 3 8 470 530 70 850 00 0 40 730 040 Clean Regulator Series SR Stainless steel regulator controlled for contamination Series SRH Series SR Series SRH Series SRH3000 SRH4000 Series SR Series SR000 SR3000 SR4000 Port size Rc (PT) /8 /4 3/8 / 9/6-8UNF 7/8-4UNF Port size Rc (PT) M5 /8 /4 3/8 / Wetted parts material Body Diaphragm Stainless steel 36L Wetted parts (Stainless steel 36 PTFE + Fluorine for wetted parts) rubber (Grade A) Fluorine rubber (Grade B) Wetted parts material Body Diaphragm Fluorine rubber Stainless steel 36 PTFE is coated on the fluorine rubber base for wetted parts. Clean Gas Filter Series SF Nominal filtration rating 0.0 µm Series SFA Series SFB Series SFC 8 Cartridge Type Series 00 SFA00 300 SFB00 Series SFB300 SFC00 Type Disc Straight Disposable Type Type Straight Multiple disc Main material Thread Port size Element Housing Seal type M5 /4 PTFE + Stainless Rc (PT) Fluorine Polyester steel 36 NPT rubber PTFE (Electropolishing) UOJ TSJ + (FPM) PFA Main material Thread Port size Element Housing Seal type /4 3/8 PTFE + Stainless Rc (PT) PFA steel 36 TSJ PTFE (Electropolishing) O-ring + URJ PVDF PTFE

Series SFD Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 444 Note ), JIS B 8370 Note ) and other safety practices. Explanation of the Labels Labels Danger Warning In extreme conditions, there is a possible result of serious injury or loss of life. Operator error could result in serious injury or loss of life. Caution Operator error could result in injury Note 3) or equipment damage. Note 4) Note ) ISO 444: Pneumatic fluid power General rules relating to systems Note ) JIS B 8370: General Rules for Pneumatic Equipment Note 3) Injury indicates light wounds, burns and electrical shocks that do not require hospitalization or hospital visits for long-term medical treatment. Note 4) Equipment damage refers to extensive damage to the equipment and surrounding devices. Selection/Handling/Applications Explanation of the labels. The compatibility of the pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications. Since the products specified here are used in various operating conditions, their compatibility for the specific pneumatic system must be based on specifications or post analysis and/or tests to meet the specific requirements. The expected performance and safety assurance are the responsibility of the person who has determined the compatibility of the system. This person should continuously review the suitability of all items specified, referring to the latest catalog information with a view to giving due consideration to any possibility of equipment failure when configuring a system.. Only trained personnel should operate pneumatically operated machinery and equipment. Compressed air can be dangerous if handled incorrectly. Assembly, handling or repair of the systems using pneumatic equipment should be performed by trained and experienced operators. (Understanding JIS B 8370 General Rules for Pneumatic Equipment, and other safety rules are included.) 3. Do not service machinery/equipment or attempt to remove components until safety is confirmed.. Inspection and maintenance of machinery/equipment should only be performed once measures to prevent falling or runaway of the driven objects have been confirmed.. When equipment is removed, confirm the safety process as mentioned above. Turn off the supply pressure for this equipment and exhaust all residual compressed air in the system, and release all the energy (liquid pressure, spring, condenser, gravity). 3. Before machinery/equipment is restarted, take measures to prevent quick extension of a cylinder piston rod, etc. 4. If the equipment will be used in the following conditions or environment, please contact SMC first and be sure to take all necessary safety precautions.. Conditions and environments beyond the given specifications, or if product is used outdoors.. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and brake circuits in press applications, or safety equipment. 3. An application which has the possibility of having negative effects on people, property, requiring special safety analysis. 4. If the products are used in an interlock circuit, prepare a double interlock style circuit with a mechanical protection function for the prevention of a breakdown. And, examine the devices periodically if they function normally or not. Exemption from Liability. SMC, its officers and employees shall be exempted from liability for any loss or damage arising out of earthquakes or fire, action by a third person, accidents, customer error with or without intention, product misuse, and any other damages caused by abnormal operating conditions.. SMC, its officers and employees shall be exempted from liability for any direct or indirect loss or damage, including consequential loss or damage, loss of profits, or loss of chance, claims, demands, proceedings, costs, expenses, awards, judgments and any other liability whatsoever including legal costs and expenses, which may be suffered or incurred, whether in tort (including negligence), contract, breach of statutory duty, equity or otherwise. 3. SMC is exempted from liability for any damages caused by operations not contained in the catalogs and/or instruction manuals, and operations outside of the specification range. 4. SMC is exempted from liability for any loss or damage whatsoever caused by malfunctions of its products when combined with other devices or software. Back page

Series SFD Specific Product Precautions Be sure to read this before handling. Refer to the back of page for Safety Instructions and Precautions for Handling Pneumatic Devices (M-03-E3A) for Common Precautions. Warning Selection. Thoroughly and carefully confirm the purpose of use, required specifications and operating conditions (fluid, pressure, flow rate, nominal filtration rating and environment) then select a model within the specifications.. The product is not certified under the High Pressure Gas Safety law, so for nitrogen, its maximum operating pressure will be 0.99 MPa (gauge pressure). 3. Contact us beforehand if the product will be used in an application such as a caisson shield, breathing, food and/or medical treatment that affects the human body directly or indirectly. Warning Mounting. Instruction manual Mount the product after reading and understanding the instruction manual. Keep it in a location where it can easily be found.. Flushing Flush the piping line when the filter is used for the first time or has been replaced. In the event of connecting such as piping, flush (air blow) when using this product for the first time or replacing its elements in order to reduce the affect of the dust generated from the connection, etc. Flushing the line is also required to eliminate contamination resulting from the piping line installation. Therefore, be sure to flush the line before actually running the system. Fix all mounting parts for use. 3. Use fittings with resin threads for the connection of fittings to the IN and OUT ports. Using fittings with metal threads could damage the IN and OUT ports. 4. Connect tubing to the IN and OUT one-touch fittings in accordance with the precautions for one-touch fittings. Caution. Connect the piping in accordance with the flow direction marked on the case. If connected in reverse, the element could break.. The mounting orientation does not affect the performance, but if excessive force is applied to the SFD00 series, the body may become disconnected from the bracket. Therefore, take particular care about the mounting orientation. Warning Caution on Installation. The material of the element is polycarbonate. The material is resistant to wiping with alcohol, but is not suitable for atmospheres or places with organic solvents, chemicals, cutting oils, synthetic oils, ester base compressor oils, alkalis or thread locking agents. Caution. If the pressure difference (pressure drop) between the inlet and the outlet exceeds 0. MPa, it can cause damage to the product.. Do not install the product in a place where it can be affected by a pulsation (including surge pressure) of over 0. MPa. 3. Use caution regarding the particles that may be emitted from the outlet side of a pneumatic equipment. Installation of a pneumatic equipment on the outlet side can deteriorate the cleanliness because a particle will be generated from the equipment. The mounting position of the pneumatic equipment needs to be considered. 4. Set the air flow capacity with an initial pressure drop of 0.03 MPa or less. If the initial pressure drop is set to be high, its service life will be shorten due to clogging. 5. Determine the product by the maximum consumption flow rate. When using compressed air for an air blow application, calculate the maximum volume of air that will be consumed before selecting the SFD series product size. 6. Generally, the following pollutant particles are contained in compressed air. [Pollutant particle substances contained in the compressed air] Moisture (drainage) Dusts and particles which are in the surrounding air Deteriorated oil which is discharged from the compressor Solid foreign matter such as rust and/or oil in the piping ) The SFD series is not compatible with compressed air which contains fluids such as water and/or oil. ) Install a dryer (IDF, IDG, ID series), mist separator (AM series), micro mist separator (AMD series), super mist separator (AME series), or odor removal filter (AMF series), etc., for the source of the air for the SFD series. 7. Using with a flow-rate much higher than its specification could lead to exceeding the differential pressure the product can resist. Use the product within its specifications. Also, take care about the replacement period of the product, taking into consideration that the differential pressure of the filter will increase over time. Back page

Series SFD Specific Product Precautions Be sure to read this before handling. Refer to the back of page for Safety Instructions and Precautions for Handling Pneumatic Devices (M-03-E3A) for Common Precautions. Caution Piping. Unpacking the sealed package Since the filter is sealed in an antistatic double bag, the inner package should be unpacked in a clean atmosphere (such as a clean room).. Apply a wrench to chamfered flats or hexagon portion on the IN side or the OUT side to prevent the housing from rotating. 3. Always tighten threads with the proper tightening torque. When attaching fittings to the product, tighten with the proper tightening torque shown below. Material Resin Metal 4. Check the arrow mark on the case which shows the flow direction to connect the IN and OUT ports correctly. If connected in reverse, the element could break. Warning Tightening torque (N m) to 3 to 4 Maintenance. Follow the maintenance procedures in the instruction manual. If handled incorrectly equipment or device can be damaged or cause a malfunction.. When removing the product, exhaust the air and ensure the air is released to atmosphere before removing it. 3. When the element comes to the end of its life, immediately replace it with a new filter or replacement element (cartridge type). Service life of element The service life of the element ends when either of the following two conditions occurs. ) After year of usage has elapsed. ) When the pressure drop reaches 0. MPa even though the operating period has been less than year. Warning Operating Environment. Do not operate under the conditions listed below due to a risk of malfunction. In locations having corrosive gases, organic solvents, and chemical solutions, or in locations in which these elements are likely to adhere to the equipment. In locations in which salt water, water, or water vapor could come in contact with the equipment. In locations that are exposed to direct sunlight. (Shield the equipment from sunlight to prevent its resin material from ultraviolet ray degradation or overheating.) In locations that have a heat source and poor ventilation. (Shield the equipment from heat sources to protect it from softening degradation due to radiated heat.) In locations that are exposed to shocks and vibrations. In locations with high humidity or a large amounts of dust.. When the product is used for blowing, use caution to prevent the work from being damaged by entrained air from the surrounding area. When the compressed air is used for air blow, the exhausted air from the blow nozzle may have taken in airborne foreign matter (such as solid particle, fluid particle) from the surround air. The foreign matter will be sprayed on the work, and the airborne foreign matter may adhere to it. Therefore, use caution for the surrounding environment. Caution Other Tube Brands.When tubing of brands other than SMC s are used, verify that the tubing O.D. satisfies the following accuracy; ) Polyolefin tube: Within ±0. mm ) Polyurethane tubing: Within +0.5 mm, within 0. mm 3) Nylon tubing: Within ±0. mm 4) Soft nylon tubing: Within ±0. mm Do not use tubing which does not meet these outside diameter tolerances. It may not be possible to connect them, or they may cause other trouble, such as air leakage or the tube pulling out after connection. The recommended tube for the clean fitting is polyolefin tube. Other tubes can satisfy the performance in terms of leakage, tensile strength, etc., but impair the cleanliness. Note this point for use. Back page 3

SMC'S GLOBAL MANUFACTURING, DISTRIBUTION AND SERVICE NETWORK EUROPE AUSTRIA SMC Pneumatik GmbH BELGIUM SMC Pneumatics N.V./S.A. BULGARIA SMC Industrial Automation Bulgaria EOOD CROATIA SMC Industrijska automatika d.o.o. CZECH REPUBLIC NORWAY SMC Pneumatics Norway A/S POLAND SMC Industrial Automation Polska Sp.z.o.o. ROMANIA SMC Romania s.r.l. RUSSIA SMC Pneumatik LLC. SLOVAKIA SMC Priemyselná automatizáciá, s.r.o. SINGAPORE SMC Pneumatics (S.E.A.) Pte. Ltd. SOUTH KOREA SMC Pneumatics Korea Co., Ltd. TAIWAN SMC Pneumatics (Taiwan) Co., Ltd. THAILAND SMC Thailand Ltd. NORTH AMERICA SMC Industrial Automation CZ s.r.o. SLOVENIA CANADA DENMARK SMC INDUSTRIJSKA AVTOMATIKA d.o.o. SMC Pneumatics (Canada) Ltd. SMC Pneumatik A/S SPAIN/PORTUGAL MEXICO ESTONIA SMC España, S.A. SMC Corporation (Mexico) S.A. de C.V. SMC Pneumatics Estonia OÜ SWEDEN USA FINLAND SMC Pneumatics Sweden AB SMC Corporation of America SMC Pneumatics Finland OY FRANCE SMC Pneumatique SA GERMANY SWITZERLAND SMC Pneumatik AG. UK SMC Pneumatics (U.K.) Ltd. SOUTH AMERICA ARGENTINA SMC Argentina S.A. SMC Pneumatik GmbH BOLIVIA GREECE ASIA SMC Pneumatics Bolivia S.R.L. SMC Hellas EPE HUNGARY SMC Hungary Ipari Automatizálási Kft. IRELAND SMC Pneumatics (Ireland) Ltd. ITALY SMC Italia S.p.A. LATVIA SMC Pnuematics Latvia SIA LITHUANIA SMC Pneumatics Lietuva, UAB NETHERLANDS SMC Pneumatics BV. CHINA SMC (China) Co., Ltd. HONG KONG SMC Pneumatics (Hong Kong) Ltd. INDIA SMC Pneumatics (India) Pvt. Ltd. INDONESIA PT. SMC Pneumatics Indonesia MALAYSIA SMC Pneumatics (S.E.A.) Sdn. Bhd. PHILIPPINES SHOKETSU-SMC Corporation BRAZIL SMC Pneumaticos Do Brazil Ltda. CHILE SMC Pneumatics (Chile) S.A. VENEZUELA SMC Neumatica Venezuela S.A. OCEANIA AUSTRALIA SMC Pneumatics (Australia) Pty. Ltd. NEW ZEALAND SMC Pneumatics (N.Z.) Ltd. Safety Instructions Be sure to read Precautions for Handling Pneumatic Devices (M-03-E3A) before using. Akihabara UDX 5F, 4-4-, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: 03-507-849 FAX: 03-598-536 URL http://www.smcworld.com 007 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. D-DN st printing LO printing LO 0DN Printed in Japan. This catalog is printed on recycled paper with concern for the global environment.