These days, I am more involving WAN Ethernet service product which is a bit complicated to

Size: px
Start display at page:

Download "These days, I am more involving WAN Ethernet service product which is a bit complicated to"

Transcription

1 These days, I am more involving WAN Ethernet service product which is a bit complicated to troubleshoot. Simply, tons of vendors and gears in the market. If you are not dealing with those devices all the time, you would spend time to play with some commands until you get output what you want. WAN Ethernet service is very popular in data communication market in compatible price. By comparing to traditional circuit, it is a lot cheaper. Also, H/W cost is cheaper. It dramatically drops your maintenance cost. For those reasons, WAN Ethernet service will get more sunshine in the market. By the way, there are many vendors out there. Seems like major players are Tellabs, Fujitsu, Cisco, Nortel, Ciena Corporation, Overture networks, Anda networks and etc. Here is the basic commands for overture ISG5100 Ethernet Switch for carriers. - To see uptime Overture_ISG5100# uptime 10:40pm up 42 days, 3:03, load average: 0.00, 0.00, / 9

2 - To see all VLAN Overture_ISG5100# port show all vlan Amt Port Type Pvid Pri Only IngF Vlan/Label Cir Burst Flow Pause 2.1 Enet 0 1 off off none N/A N/A N/A N/A 2.2 Enet 0 1 off off none N/A N/A N/A N/A 2.3 Enet 0 1 off off none N/A N/A N/A N/A 2.4 Enet 0 1 off off none N/A N/A N/A N/A 2.5 Enet 0 1 off off none N/A N/A N/A N/A 2.6 Enet 0 1 off off none N/A N/A N/A N/A 2.7 Enet 0 1 off off none N/A N/A N/A N/A 2.8 Enet 0 1 off off none N/A N/A N/A N/A 3.1 OC3 0 1 off off mgmt 1 2 N/A N/A - To show L2 class interface Overture_ISG5100# l2classify show Egress Rate Limt RuleName Pri Port VLAN DSCP Pbit Port Q Action Cir/Burst PBit DSCP OVR any any any PU/ / 100 no no OVR any any PO/ n/a no/ 0 no no - To check a status of port Overture_ISG5100# port show 1.1 status 2 / 9

3 Showing Port status Port Type Admin Oper Duplex Speed AutoNeg Lpbk RxErrTotal 1.1 Enet up up Full 100M n/a disab To see port configuration Overture_ISG5100# port show 1.1 config Admt Dot InFwd Spd Full Auto Port Type Admin Learn Polc Jmbo Only 1p Mode 100M Dup Neg Xovr 1.1 Enet up off off on off off sw/br on on off mdi Overture_ISG5100# - To check VLAN setup Overture_ISG5100# port show 1.1 vlan Amt Port Type Pvid Pri Only IngF Vlan/Label Cir Burst Flow Pause 1.1 Enet 0 1 off off none N/A N/A N/A N/A - To check details of the port Overture_ISG5100# port show 1.1 detail 3 / 9

4 Showing port details Port Type Drops Rx Tx Q Disc Bundle 1.1 Enet N/A - To check detail counters Overture_ISG5100# port show 1.1 detail counters Showing port detailed counters -- Counters for TX_BYTES_GOOD RX_BYTES_GOOD TX_BYTES_TOTAL RX_BYTES_TOTAL TX_UNICAST_PKTS RX_SHORT_PKTS_GOOD TX_MULTICAST_PKTS RX_SHORT_PKTS_BAD TX_BROADCAST_PKTS RX_LONG_PKTS_GOOD TX_PAUSE_PKTS RX_LONG_PKTS_BAD TX_VLAN_PKTS RX_UNICAST_PKTS TX_CRC_ERRS RX_MULTICAST_PKTS TX_DEFERS RX_BROADCAST_PKTS TX_EXCESS_DEFERS RX_PAUSE_PKTS TX_SINGLE_COLS RX_VLAN_PKTS TX_MULTI_COLS RX_CRC_ERRS TX_EXCESS_COLS RX_ALIGN_ERRS TX_LATE_COLS RX_RUNTS TX_NORM_COLS RX_LENGTH_ERRS TX_FIFO_ERRS RX_FALSE_CRS TX_PKTS_ RX_PHY_ERRS TX_PKTS_ RX_FIFO_ERRS TX_PKTS_ RX_IGNORED TX_PKTS_ RX_OPCODE_BAD TX_PKTS_ RX_PKTS_ TX_PKTS_ RX_PKTS_ RX_PKTS_ RX_PKTS_ RX_PKTS_ RX_PKTS_ / 9

5 - To clear PM counters Overture_ISG5100# port clear 1.1 pm-counters - To see PM result, only apply serial link not Ethernet. Overture_ISG5100# port show 3.1 pm Showing PM Counters Port Type Section ES SES SEFS CV Port Type Line ES SES CV UAS Port Type FarendLine FEES FESES FESCV FEUAS Port Type Path ES SES CV UAS Port Type FarendPath FEES FESES FECV FEUAS Overture_ISG5100# - To see queues Overture_ISG5100# port show all detail queues 5 / 9

6 Port Type Cntr Queue0 Queue1 Queue2 Queue3 Queue4 Queue5 Queue6 1.1 GigSFP Bytes Pkts OC3 Bytes Pkts To see errors on the interface Overture_ISG5100# port show 1.1 errors Showing Port Errors Port Type RxCrc RxAlign RxRunt RxLength RxCrs RxPhy RxFifo 1.1 Enet To see live traffic on the link, default interval is 5 sec Overture_ISG5100# port show 1.1 util Per Second Utilization for Port(s) 1.1 Count=0 DisplayTime=5 Secs Port Type TxPkts RxPkts TxBits RxBits Tx % Rx % 1.1 Enet Kbps Mbps Port Type TxPkts RxPkts TxBits RxBits Tx % Rx % 1.1 Enet Kbps Mbps To see log for alrams 6 / 9

7 Overture_ISG5100# log show alarm Aug 13 19:31:53 isg5000 isgservices: FAULT TIME="Thu Aug 13 19:31: " SEVERITY="Major" SLOT="Slot 3" DEVICE="port 1" ID="Section Loss of Frame (LOF)" SEQUENCE NUMBER="1" Aug 13 19:31:54 isg5000 isgservices: FAULT TIME="Thu Aug 13 19:31: " SEVERITY="Cleared" SLOT="Slot 3" DEVICE="port 1" ID="Section Loss of Frame (LOF)" SEQUENCE NUMBER="2" Aug 13 19:33:12 isg5000 isgservices: FAULT TIME="Thu Aug 13 19:33: " SEVERITY="Critical" SLOT="Slot 1" DEVICE="port 1" ID="Link failure" SEQUENCE NUMBER="3" Aug 13 19:34:36 isg5000 isgservices: FAULT TIME="Thu Aug 13 19:34: " SEVERITY="Cleared" SLOT="Slot 1" DEVICE="port 1" ID="Link failure" SEQUENCE NUMBER="4" Aug 13 19:34:49 isg5000 isgservices: FAULT TIME="Thu Aug 13 19:34: " SEVERITY="Critical" SLOT="Slot 1" DEVICE="port 1" ID="Link failure" SEQUENCE NUMBER="5" Aug 13 19:45:37 isg5000 isgservices: FAULT TIME="Thu Aug 13 19:45: " SEVERITY="Cleared" SLOT="Slot 1" DEVICE="port 1" ID="Link failure" SEQUENCE NUMBER="6" Aug 13 19:46:37 isg5000 isgservices: FAULT TIME="Thu Aug 13 19:46: " SEVERITY="Critical" SLOT="Slot 1" DEVICE="port 1" ID="Link failure" SEQUENCE NUMBER="7" - To see log for command history Overture_ISG5100# log show command Sep 1 12:48:10 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show all vlan" Sep 1 12:52:40 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show 1.1 status" Sep 1 12:52:56 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show 1.1 detail" Sep 1 12:52:58 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show 1.1 detail" Sep 1 12:53:16 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show 1.1 detail counters" Sep 1 12:54:12 isg5000 cli_sh: CLI USER="AshburnCMC" 7 / 9

8 IP_ADDR=" " CMD="port show 1.1 detail counters" Sep 1 12:54:13 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show 1.1 status" Sep 1 12:54:18 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show 1.1 status" Sep 1 12:54:40 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show 1.1 counters " Sep 1 12:54:52 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show 1.1 detail" Sep 1 12:54:57 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show 1.1 detail counters" Sep 1 12:55:09 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show 1.1 status" : : - To see all config Overture_ISG5100# show status - To see start configuration Overture_ISG5100# config show 8 / 9

9 9 / 9

PTP 800 SPLIT-MOUNT SOLUTION

PTP 800 SPLIT-MOUNT SOLUTION TM PTP 800 SPLIT-MOUNT SOLUTION LICENSED ETHERNET MICROWAVE FOR MULTI-SERVICE NETWORKS Cambium Point-to-Point (PTP) 800 Licensed Ethernet Microwave Solutions can efficiently and affordably transport the

More information

Configuring Bidirectional Forwarding Detection for BGP

Configuring Bidirectional Forwarding Detection for BGP CHAPTER 7 Configuring Bidirectional Forwarding Detection for BGP This chapter describes how to configure Bidirectional Forwarding Detection (BFD) for BGP. This chapter includes the following sections:

More information

Implementing BFD. BFD over Bundle. Enabling BFD Sessions on Bundle Members SUMMARY STEPS DETAILED STEPS

Implementing BFD. BFD over Bundle. Enabling BFD Sessions on Bundle Members SUMMARY STEPS DETAILED STEPS Bidirectional forwarding detection (BFD) provides low-overhead, short-duration detection of failures in the path between adjacent forwarding engines. BFD allows a single mechanism to be used for failure

More information

MOTOROLA PTP 800 LICENSED ETHERNET MICROWAVE

MOTOROLA PTP 800 LICENSED ETHERNET MICROWAVE HIGH-THROUGHPUT COMMUNICATIONS FOR MULTI-SERVICE NETWORKS MOTOROLA PTP 800 LICENSED ETHERNET MICROWAVE PTP 800 solutions can efficiently and affordably transport the data, voice and video that your bandwidth-intensive

More information

Session Objectives. At the end of the session, the participants should: Understand advantages of BFD implementation on S9700

Session Objectives. At the end of the session, the participants should: Understand advantages of BFD implementation on S9700 BFD Features Session Objectives At the end of the session, the participants should: Understand advantages of BFD implementation on S9700 Understand when to use BFD on S9700 1 Contents BFD introduction

More information

Product Overview. Product Description CHAPTER

Product Overview. Product Description CHAPTER CHAPTER 1 This chapter provides a functional overview of the Cisco Redundant Power System 2300 and covers these topics: Product Description, page 1-1 Features, page 1-3 Supported Devices, page 1-4 Deployment

More information

Airflow Options for Cisco MDS 9396S SAN Switch

Airflow Options for Cisco MDS 9396S SAN Switch Airflow Options for Cisco MDS 9396S SAN Switch This document describes how to configure, administer and troubleshoot airflow options in the MDS 9396S switch. Anyone can use this document along with hardware

More information

Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions)

Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions) Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions) 1. Uncrate blender from packaging. 2. Lift the blender and position over machine throat or floor

More information

Domino DUEMMEGI. Domino. Communication Interface DFTS User s Manual. Release September 2007

Domino DUEMMEGI. Domino. Communication Interface DFTS User s Manual. Release September 2007 Domino Domino Communication Interface DFTS User s Manual Release 2.3 - September 2007 srl Via Longhena 4-20139 MILANO Tel. 02/57300377 - FAX 02/55213686 Domino - DFTS: User s Manual R.2.3 Index 1- INTRODUCTION...3

More information

Technical Bulletin, Communicating with Gas Chromatographs

Technical Bulletin, Communicating with Gas Chromatographs Last Updated: 13- July-2010 TB-080000C Technical Bulletin, Communicating with Gas Chromatographs OMNI FLOW COMPUTERS, INC. 12620 West Airport Boulevard, Suite 100 Sugar Land, Texas 77478 United States

More information

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel DTLS Manual This document contains proprietary information. Copyright 2015 Scientific Data Systems, Inc. All rights reserved. 1 Depth Tension

More information

UG4: OPEN HAB. Elelabs ZigBee RPi Shield firmware version, referenced in this guide: OpenHab2 software version, referenced in this guide: v2.3.

UG4: OPEN HAB. Elelabs ZigBee RPi Shield firmware version, referenced in this guide: OpenHab2 software version, referenced in this guide: v2.3. UG4: OPEN HAB This document describes how to use Elelabs ZigBee RPi Shield (https://elelabs.com/products/elelabs_zigbee_shield.html) with existing Home Automation platform called OpenHAB (https://www.openhab.org/).

More information

HART Communications Board

HART Communications Board - HART Communications Board (Highway Addressable Remote Transducer) User Manual Document No. Sensidyne, LP. 1000 112 th Circle N, Suite 100 St. Petersburg, Florida 33716 USA 800-451-9444 +1 727-530-3602

More information

Doc. no.dit om005 PRODUCT NAME. IO-Link/ELECTRO-PNEUMATIC REGULATOR. MODEL / Series / Product Number ITV*0*0-IO****-X395

Doc. no.dit om005 PRODUCT NAME. IO-Link/ELECTRO-PNEUMATIC REGULATOR. MODEL / Series / Product Number ITV*0*0-IO****-X395 Doc. no.dit-69900-om005 PRODUCT NAME IO-Link/ELECTRO-PNEUMATIC REGULATOR MODEL / Series / Product Number ITV*0*0-IO****-X395 This is the operation manual for the IO-Link compliant ITV. For other contents

More information

Bidirectional Forwarding Detection Routing

Bidirectional Forwarding Detection Routing This chapter describes how to configure the ASA to use the Bidirectional Forwarding Detection (BFD) routing protocol. About BFD Routing, page 1 Guidelines for BFD Routing, page 5 Configure BFD, page 5

More information

MP15 Jockey Pump Controller

MP15 Jockey Pump Controller Setup and Operating Instructions MP15 Jockey Pump Controller This manual provides general information, installation, operation, maintenance, and system setup information for Metron Model MP15 Jockey Pump

More information

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual Air Bubbler Depth Gauge DG2200 Installation and Reference Manual Rev. 3.2.2 06/2011 Installation and Reference Manual Page 2 Contents Chapter 1: Installation and Overview... 3 1.1 DG2200 Location Diagram...

More information

Stand-Alone Bubble Detection System

Stand-Alone Bubble Detection System Instruction Sheet P/N Stand-Alone Bubble Detection System 1. Introduction The Bubble Detection system is designed to detect air-bubble induced gaps in a bead of material as it is being dispensed. When

More information

SteelHead Interceptor Appliance Installation Guide. Version 5.0 July 2015

SteelHead Interceptor Appliance Installation Guide. Version 5.0 July 2015 SteelHead Interceptor Appliance Installation Guide Version 5.0 July 2015 2015 Riverbed Technology, Inc. All rights reserved. Riverbed and any Riverbed product or service name or logo used herein are trademarks

More information

APPENDIX 10, Automation Standard

APPENDIX 10, Automation Standard APPENDIX 10, Automation Standard to Arla Foods Group Agreement for Purchase of Machinery including installation Software Design Specification Seller (company) Document responsible (Seller) Description

More information

Datasheet: K-30 ASCII Sensor

Datasheet: K-30 ASCII Sensor Datasheet: K-30 ASCII Sensor The K30 ASCII sensor is a low cost, infrared and maintenance free transmitter module intended to be built into different host devices that require CO2 monitoring data. The

More information

Pressure Automated Calibration Equipment

Pressure Automated Calibration Equipment GE Measurement & control Pressure Automated Calibration Equipment Safety Instructions and User Guide - K0447 PACE5000 PACE6000 K0447 Issue No. 9 1 10 1 PACE5000 1 2 3 4 5 PACE6000 2 6 7 8 3 4 5 6 7 8 9

More information

Digi Connect ME 9210 Linux: serial port 2 for JTAG modules

Digi Connect ME 9210 Linux: serial port 2 for JTAG modules Digi Connect ME 9210 Linux: serial port 2 for JTAG modules Document History Date Version Change Description 08/05/2009 Initial entry/outline Table of Contents Document History... 2 Table of Contents...

More information

LENNOX SLP98UHV DIAGNOSTIC CODES

LENNOX SLP98UHV DIAGNOSTIC CODES Code Status of Equipment Action required to clear and recover - Idle mode (Decimal blinks at 1 Hertz -- 0.5 second ON, 0.5 second OFF) A Cubic feet per minute (cfm) setting for indoor blower (1 second

More information

User manual CF8-D/W-IN

User manual CF8-D/W-IN User manual CF8-D/W-IN General The sensor CF8-D/W-IN is used to measure the carbon dioxide concentration inside incubators. All functions can be modified from a PC with the communication cable. UMA 48

More information

Digi Connect ME 9210 Linux: 2 nd serial over FIM

Digi Connect ME 9210 Linux: 2 nd serial over FIM Digi Connect ME 9210 Linux: 2 nd serial over FIM Document History Date Version Change Description 09/04/2009 Initial entry/outline Table of Contents Document History... 2 Table of Contents... 2 1 Problem

More information

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values Operations Manual Please read, understand, and follow these instructions before operating this equipment.

More information

Page 2 of 46 Prepared by: Engr. Ram Sankar

Page 2 of 46 Prepared by: Engr. Ram Sankar Page 2 of 46 CHAPTER 1 GETTING STARTED Page 3 of 46 Establishing Communication with Relay: 1. Open MICOM S1 studio and click on NEW SYSTEM. 2. Name it and save on desired location and click on OK. Page

More information

TECNAUTIC_GmbH. Display Functions with the PB100/200 connected: -- GND Speed -- GND Course -- Heading (Gyro option is recommended) 2 m

TECNAUTIC_GmbH. Display Functions with the PB100/200 connected: -- GND Speed -- GND Course -- Heading (Gyro option is recommended) 2 m PB100/200 Sonic Wind Wind, GPS, Compass Display Config: SE=12 di=00 df=20,91,30,34,(61) 35,36,81 Gr=01 n0=00 n1=07 n2=07**) n3=00 Display Functions with the PB100/200 connected: -- Apparent Wind -- True

More information

HOT SPOT MONITOR (HSM)

HOT SPOT MONITOR (HSM) HOT SPOT MONITOR (HSM) EDS FILE TECHNICAL NOTE INSERTING EDS TO ROCKWELL STUDIO 5000 Follow the below steps to add GraceSense TM Hot Spot Monitor (HSM) product via Ethernet IP to your project. Download

More information

*24 RF HOUSE ID CODE [00] 00 = Disable all wireless touchpad usage = using 5827 or 5827BD touchpad

*24 RF HOUSE ID CODE [00] 00 = Disable all wireless touchpad usage = using 5827 or 5827BD touchpad PROGRAMMING FORM Local programming requires the use of a 2-line Alpha keypad connected to partition 1 keypad terminals on the control. NOTE: For UL installations, the system may be configured as a single

More information

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock Eliminator Competition Stand Alone Mode - Instruction Manual Main Menu: After startup, the Eliminator Competition will enter the Main Menu. Press the right/left arrow buttons to move through the menu.

More information

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408) RACEAMERICA T i m i n g S y s t e m s Demo Tree Controller Owner s Manual Models 3204D, 3204DW & 3204DX Rev D RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA 95055-3469 (408) 988-6188 http://www.raceamerica.com

More information

Residential Ultrasonic Gas Meters

Residential Ultrasonic Gas Meters Residential Ultrasonic Gas Meters Published in Electronics and Telecommunications (ISETC), 2014 11th International Symposium on DOI: 10.1109/ISETC.2014.7010758 pp. 101-105 Laurentiu Gavra Timişoara, Romania

More information

THE MERTON GROUP. Municipal Broadband Networks Infrastructure Merrimack, NH. The Merton Group Copyright The Merton Group, LLC Page 1

THE MERTON GROUP. Municipal Broadband Networks Infrastructure Merrimack, NH. The Merton Group Copyright The Merton Group, LLC Page 1 THE MERTON GROUP Municipal Broadband Networks Infrastructure Merrimack, NH The Merton Group Copyright The Merton Group, LLC Page 1 Methodology The Merton Group Copyright The Merton Group, LLC Page 2 Commence

More information

STAND alone & p.c. VERSION

STAND alone & p.c. VERSION STAND alone & p.c. VERSION ECONOMY TRACK SYSTEMS 1/4 & 1/8 Mile Asphalt Track Dirt / Sand Track Mud Track Snowmobile Track R/C Car Track Custom Track Systems Timing to.001 Accuracy Time Slip Printer Optional

More information

CUSTOMER INFORMATION

CUSTOMER INFORMATION CUSTOMER INFORMATION COMPANY NAME & ADDRESS: CONTACT: PHONE: FAX: NOTES: DATE ENTERED: DATE MODIFIED: 05/2/28 11:10 A 11/5/2010 11:17 A COMMENTS 1: COMMENTS 2: Vista20P-9(IP) PROGRAMMING FORM Local programming

More information

Cryostream 800 Series

Cryostream 800 Series Cryostream 800 Series Cryostream 800 Series Nearly 30 years after the invention of the first Cryostream Cooler, Oxford Cryosystems is proud to announce the launch of the new 800 series Cryostream. The

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

SteelHead SaaS User s Guide

SteelHead SaaS User s Guide SteelHead SaaS User s Guide RiOS Version 9.6 March 2017 2017 Riverbed Technology, Inc. All rights reserved. Riverbed and any Riverbed product or service name or logo used herein are trademarks of Riverbed.

More information

How to use Bidirectional Forwarding Detection(BFD) in NetScaler?

How to use Bidirectional Forwarding Detection(BFD) in NetScaler? How to use Bidirectional Forwarding Detection(BFD) in NetScaler? Bidirectional Forwarding Detection commonly referred as BFD is a simple hello protocol that provides fast failure detection mechanism between

More information

In Vivo Scientific, LLC INSTRUCTION MANUAL

In Vivo Scientific, LLC INSTRUCTION MANUAL CO 2 Controller In Vivo Scientific, LLC INSTRUCTION MANUAL CONTENTS CONTENTS...1 ABOUT THIS MANUAL...2 INTRODUCTION...2 Cautions and Warnings...2 Parts List...2 Unpacking...2 INSTRUMENT DESCRIPTION...3

More information

Autopilot setup. VRF (Virtual Rudder Feedback) calibration. Software setup NSS evo2 Installation Manual

Autopilot setup. VRF (Virtual Rudder Feedback) calibration. Software setup NSS evo2 Installation Manual Autopilot setup Verifying the autopilot connection When an AC12N, AC42N, or SG05 is connected to the NSS evo2 system, the NSS evo2 will automatically detect the autopilot and an Autopilot menu icon will

More information

Manual Weighingblock VB2 series and Uniscale

Manual Weighingblock VB2 series and Uniscale Manual Weighingblock VB2 series and Uniscale Note: At page 8 in this manual you will find a short form instruction. Normally the only instruction shipped together with the Scale. Overview different ranges.

More information

User Manual MFCS TM -EZ

User Manual MFCS TM -EZ User Manual MFCS TM -EZ Version 6A_December 2016 1. INTRODUCTION 5 2. GENERAL INFORMATION 6 2.1 General functioning 6 2.2 Different MFCS TM 6 3. PACKAGE CONTENT 8 4. MFCS TM -EZ DESCRIPTION 9 5. CONNECTIONS

More information

XC2 Client/Server Installation & Configuration

XC2 Client/Server Installation & Configuration XC2 Client/Server Installation & Configuration File downloads Server Installation Backup Configuration Services Client Installation Backup Recovery Troubleshooting Aug 12 2014 XC2 Software, LLC Page 1

More information

THE MERTON GROUP. Municipal Broadband Networks Infrastructure Princeton, MA. The Merton Group Copyright The Merton Group, LLC Page 1

THE MERTON GROUP. Municipal Broadband Networks Infrastructure Princeton, MA. The Merton Group Copyright The Merton Group, LLC Page 1 THE MERTON GROUP Municipal Broadband Networks Infrastructure Princeton, MA The Merton Group Copyright The Merton Group, LLC Page 1 Methodology The Merton Group Copyright The Merton Group, LLC Page 2 Commence

More information

Rcvr-Acct#: Date: May 3, :31 AM

Rcvr-Acct#: Date: May 3, :31 AM 32P1-5 PROGRAMMING FORM Local programming requires the use of a 2-line Alpha keypad connected to partition 1 keypad terminals on the control. NOTE: For UL installations, the system may be configured as

More information

ISU 2x64 Dual Port ISDN Service Unit User Manual

ISU 2x64 Dual Port ISDN Service Unit User Manual ISU 2x64 Dual Port ISDN Service Unit User Manual Part Numbers 1200051L1 1200051L2 1200051L5 1200051L6 U-Interface Version, 110 VAC S/T-Interface Version, 110 VAC S/T-Interface International, 110 VAC S/T-Interface

More information

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com Operating Manual Software for Fire and Gas Warning Units Order No.: 10154656/01 MSAsafety.com MSA Europe GmbH Schlüsselstrasse 12 8645 Rapperswil-Jona Switzerland info.ch@msasafety.com www.msasafety.com

More information

PRODUCT MANUAL. Diver-MOD

PRODUCT MANUAL. Diver-MOD PRODUCT MANUAL Diver-MOD Contents 1 Introduction... 1 1.1 Scope and Purpose... 1 1.2 Features... 1 1.3 System Overview... 1 1.4 Specifications... 2 2 Getting Started... 2 2.1 Supported Equipment... 2 2.2

More information

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6 LT GasAnalyzer LT GasAnalyzer Page 1 of 6 LT GasAnalyzer Disturbances in the protective gas supply can cause production losses or affect product quality. In the worst case, it even can endanger life and

More information

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc. The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is

More information

Safety Manual VEGAVIB series 60

Safety Manual VEGAVIB series 60 Safety Manual VEGAVIB series 60 Contactless electronic switch Document ID: 32002 Contents Contents 1 Functional safety... 3 1.1 General information... 3 1.2 Planning... 4 1.3 Adjustment instructions...

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

CNC Communication Protocol

CNC Communication Protocol CNC Communication Protocol Commands and Serial/Discrete Signals for the XPR Cutting System 809810 Revision 3 January 2018 CNC Communication Protocol for the XPR Cutting System 1 Contents Before you begin...

More information

Surge suppressor To perform its intended functions, an AEI site must have the components listed above and shown in Fig. 4.1.

Surge suppressor To perform its intended functions, an AEI site must have the components listed above and shown in Fig. 4.1. 4.0 COMPONENT FEATURES AND REQUIREMENTS An AEI site should include the following component subsystems: Presence detector Wheel detector Tag reader Controller Communications Power supply Surge suppressor

More information

Drag racing system HL190 User Manual and installation guide

Drag racing system HL190 User Manual and installation guide Drag racing system HL190 User Manual and installation guide Version 10/2015 TAG Heuer Timing Page 1 / 14 1. Global This software controls the whole Drag racing installation HL190. Combined with the Chronelec

More information

Panther 5 Acute Care Ventilator

Panther 5 Acute Care Ventilator 1 HIGHLIGHTS High performance and advanced features target the ICU environment Utilizes an internal blower with a specially designed flow control valve removing the need for using compressed air without

More information

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x Electrical Installation Requirements Care should be taken to separate the power and signal cables to prevent electrical interference and possible damage due to inadvertent connection. SUPPLY E L N LN2

More information

Certification Exhibit FCC ID: R7PIWRS4. FCC Rule Part: ACS Report Number: W03.11.A

Certification Exhibit FCC ID: R7PIWRS4. FCC Rule Part: ACS Report Number: W03.11.A Certification Exhibit FCC ID: R7PIWRS4 FCC Rule Part: 15.247 ACS Report Number: 09-0412.W03.11.A Manufacturer: Cellnet Technology Inc. Model: Gridstream DCIWR Manual 5015 B.U. Bowman Drive Buford, GA 30518

More information

securing networks with silicon

securing networks with silicon NITROX II A Family of In-line Security Processors Presented by: Muhammad Raghib Hussain Contributed by: Bob Sanzone, Dan Katz, David Asher, David Carlson, Gregg Bouchard, Michael Bertone, Muhammad Hussain,

More information

ACI_Release_Notes.txt VERSION Fixed Tank info for ELITE in Dive section 2. Fixed USB port initializing for old DC VERSION

ACI_Release_Notes.txt VERSION Fixed Tank info for ELITE in Dive section 2. Fixed USB port initializing for old DC VERSION VERSION 2.4.0 1. Fixed Tank info for ELITE in Dive section 2. Fixed USB port initializing for old DC VERSION 2.3.9 1. Fixed Dive Computer configuration section error 2. Fixed message for download/upload

More information

μsmartdigi Presented at Ham-Com 2008 Plano Texas June 2008 by Rich Painter, AB VO Painter Engineering, Inc.

μsmartdigi Presented at Ham-Com 2008 Plano Texas June 2008 by Rich Painter, AB VO Painter Engineering, Inc. μsmartdigi Presented at Ham-Com 2008 Plano Texas 13-14 June 2008 by Rich Painter, AB VO Painter Engineering, Inc. μsmartdigi μsmartdigi APRS Digipeater μsmartdigi New Features If time permits... μsmartdigi

More information

CMC Peer-to-Peer Control System Software. User s Manual Version 1.0

CMC Peer-to-Peer Control System Software. User s Manual Version 1.0 CMC Peer-to-Peer Control System Software User s Manual Version 1.0 2 22562920 Rev. 03 Date of Issue: 6/12/07 PREFACE Information and Illustrations Information and illustrations are not binding. Ingersoll-Rand

More information

SAUTER flexotron 800 heating. List of network variables for Modbus communication. Manual P A P

SAUTER flexotron 800 heating. List of network variables for Modbus communication. Manual P A P SAUTER flexotron 800 heating List of network variables for communication Manual P100013118 A P100012094 2/90 P100013118 A Content Content 1 General notes 5 1.1 Disclaimer 5 1.2 Trademarks 5 2 Preface 7

More information

Timex Ironman Run Trainer Powered by GPS Technology

Timex Ironman Run Trainer Powered by GPS Technology Timex Ironman Run Trainer Powered by GPS Technology Pace and distance powered by GPS gives you the freedom to run anywhere. No more tracks, treadmills or repetitive loops to calculate distance. Just start

More information

The Universal Translator

The Universal Translator The Universal Translator David Cornfield dcornfield@apm.com Accellera Systems Initiative 1 Traditional Agents A Agent A Agent Chip ~ s m d A ~ s m d A B Agent B Agent m ~ s d B m ~ s d B Unit Level Chip

More information

1. Hardware Bookkeeping & Adjustment Access Flow Chart... 6 System Adjustment... 7 Chance Adjustment... 8 Touch Screen Calibration...

1. Hardware Bookkeeping & Adjustment Access Flow Chart... 6 System Adjustment... 7 Chance Adjustment... 8 Touch Screen Calibration... Table of Contents 1. Hardware... 2 Connectors Descriptions... 2 Connection Diagram... 3 DIP Switch Settings... 4 36 & 10 PIN Button Layout... 4 Solving Hopper SSR Error... 5 2. Bookkeeping & Adjustment...

More information

UE- 90- X X X X X X O P E R AT I N G M A N UA L 0 TO 90 HYDRAULIC UPENDER

UE- 90- X X X X X X O P E R AT I N G M A N UA L 0 TO 90 HYDRAULIC UPENDER UE- 90- X X X X X X O P E R AT I N G M A N UA L ADDRESS 2230 Brush College Road Decatur, IL 62526 Phone: 217-423-6001 Fax: 217-422-1049 E-mail: sales@alignprod.com www.alignproductionsystems.com UE-90-XXXXXX

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE Page 1 / 4 Certificate number: 23445/A0 BV File number: AP 4160 Product code: 4440I This certificate is not valid when presented without the full attached schedule composed of 7 sections www.veristar.com

More information

Manual Leveling Control Installation/Operation

Manual Leveling Control Installation/Operation ELECTROMECHANICAL TRIM TAB SYSTEMS Manual Leveling Control Installation/Operation Linear Devices Corporation dba Lectrotab 11126 Air Park Road, Suite G Ashland, VA 23005 www.lectrotab.com Phone: 804-368-8428

More information

Design Envelope Booster. Sequence of operation

Design Envelope Booster. Sequence of operation Design Envelope Booster Sequence of operation File No: 62.835 Date: february 11, 2015 Supersedes: 62.835 Date: july 11, 2014 sequence of operation Design Envelope Booster 2 general The packaged domestic

More information

TOSVERT VF-FS1 series APOGEE FLN option unit Function Manual APG002Z NOTICE

TOSVERT VF-FS1 series APOGEE FLN option unit Function Manual APG002Z NOTICE TOSVERT VF-FS1 series APOGEE FLN option unit Function Manual APG002Z NOTICE 1. Make sure that this instruction manual is delivered to the end user of APOGEE FLN option unit. 2. Read this manual before

More information

Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST)

Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST) Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST) Application Positioner firmware for early detection of control valve faults giving maintenance recommendations. Valid

More information

White Rabbit Applications for Data Acquisition Systems

White Rabbit Applications for Data Acquisition Systems White Rabbit Applications for Data Acquisition Systems Dimitris Lampridis CERN BE-CO Hardware and Timing section DAQ Meeting, IN2P3, 01 June 2016 Dimitris Lampridis WR in DAQ 1/36 1 White Rabbit 2 WR Demo

More information

2. USER INSTRUCTION. Table of contents: Pg.1/14 N:\FAP-2000: LWP

2. USER INSTRUCTION. Table of contents: Pg.1/14 N:\FAP-2000: LWP Pg.1/14 2. USER INSTRUCTION. Table of contents: 2.1 SHORT PANEL DESCRIPTION...... Pg.2 2.2 AUTOPILOT TAKE-OVER & MODE SELECTION....... Pg.3 2.3 AUTOPILOT FUNCTIONS....... Pg.3 2.4 THE SPECIAL FUNCTION

More information

with O 2 Controller Instruction Manual

with O 2 Controller Instruction Manual 14500 Coy Drive, Grass Lake, Michigan 49240 734-475-2200 E-mail: sales@coylab.com www.coylab.com Hypoxic Cabinets (In-Vivo / In-Vitro) with O 2 Controller Instruction Manual Index Page Warranty 2 Warnings

More information

Device Description User Manual Logix 520MD Positioners

Device Description User Manual Logix 520MD Positioners Device Description User Manual Logix 520MD Positioners GENERAL INFORMATION... 3 INTRODUCTION... 3 QUALIFIED PERSONNEL... 3 USING THIS DOCUMENT... 3 TERMS CONCERNING SAFETY... 3 1 STATUS... 4 1.1 CMD SOURCE...

More information

1. Hardware Hardware Connection... 2 Connection Diagram... 3 DIP Switch Settings & 10 PIN Button Layout... 4

1. Hardware Hardware Connection... 2 Connection Diagram... 3 DIP Switch Settings & 10 PIN Button Layout... 4 Table of Contents 1. Hardware... 2 Hardware Connection... 2 Connection Diagram... 3 DIP Switch Settings... 4 36 & 10 PIN Button Layout... 4 2. Bookkeeping & Adjustment... 5 Access Flow Chart... 5 System

More information

Astral in AirView: Improving patient care through connectivity. ResMed.com

Astral in AirView: Improving patient care through connectivity. ResMed.com Astral in AirView: Improving patient care through connectivity ResMed.com Using Astral in AirView via the ResMed Connectivity Module (RCM) Astral is ResMed s portable, invasive and non-invasive life support

More information

SIDRA INTERSECTION 6.1 UPDATE HISTORY

SIDRA INTERSECTION 6.1 UPDATE HISTORY Akcelik & Associates Pty Ltd PO Box 1075G, Greythorn, Vic 3104 AUSTRALIA ABN 79 088 889 687 For all technical support, sales support and general enquiries: support.sidrasolutions.com SIDRA INTERSECTION

More information

Integrate Riverbed SteelHead. EventTracker v8.x and above

Integrate Riverbed SteelHead. EventTracker v8.x and above EventTracker v8.x and above Publication Date: March 27, 2018 Abstract This guide provides instructions to configure a Riverbed SteelHead to send its syslog to EventTracker Enterprise Scope The configurations

More information

Monsoon3V+ Multiple Pump VFD Control System. Please pass these instructions on to the operator of this equipment.

Monsoon3V+ Multiple Pump VFD Control System. Please pass these instructions on to the operator of this equipment. Monsoon3V+ Multiple Pump VFD Control System Please pass these instructions on to the operator of this equipment. INTRODUCTION MONSOON 3V+ Pump Controller The MONSOON 3V+ pump control system is a fully

More information

This Manual Part recommends functional/operating guidelines for control of automatic grade crossing warning systems. Draft

This Manual Part recommends functional/operating guidelines for control of automatic grade crossing warning systems. Draft Recommended Functional/Operating Guidelines for Control of Automatic Grade Crossing Warning Systems Revised 2017 (6 Pages) A. Purpose This Manual Part recommends functional/operating guidelines for control

More information

Paper Presentation: COMPLETE AND SIMULTANEOUS DCS FAILURE IN TWO 500MW UNITS

Paper Presentation: COMPLETE AND SIMULTANEOUS DCS FAILURE IN TWO 500MW UNITS INDIAN POWER STATIONS POWER PLANT O&M CONFERENCE - 2012 Paper Presentation: COMPLETE AND SIMULTANEOUS DCS FAILURE IN TWO 500MW UNITS K C Tripathy, DGM (C&I) Anoop K, Dy Manager (C&I) B K Rathore, Dy Manager

More information

SteelHead SD Installation Guide

SteelHead SD Installation Guide SteelHead SD Installation Guide Models 570-SD, 770-SD, 3070-SD SteelConnect 2.5, RiOS 9.2.1-cf1 November 2016 2018 Riverbed Technology, Inc. All rights reserved. Riverbed and any Riverbed product or service

More information

A4021 Series VALVE PROVING SYSTEM

A4021 Series VALVE PROVING SYSTEM UNIVERSA GAS VAVES A4021 Series VAVE PROVING SYSTEM APPICATION PRODUCT HANDBOOK The A4021 is a self--checking microprocessor based Valve Proving System (VPS). The A4021 checks the effective closure of

More information

BASnet LightiView Install Guide

BASnet LightiView Install Guide BASnet LightiView 1025 Cobb Place Blvd Suite 100 Kennesaw, GA 30144 800-241-9173 www.triateklighting.com ATTENTION This section serves as a notice of the immediate or potential dangers involved when working

More information

A4s Operation Manual

A4s Operation Manual A4s Operation Manual Safety Instruction Please read this manual carefully, also with related manual for the machinery before use the controller. For installing and operating the controller properly and

More information

Instrument pucks. Copyright MBARI Michael Risi SIAM design review November 17, 2003

Instrument pucks. Copyright MBARI Michael Risi SIAM design review November 17, 2003 Instrument pucks Michael Risi SIAM design review November 17, 2003 Instrument pucks Pucks and Plug-and-Work The MBARI puck prototype Puck software interface Pucks in practice (A Puck s Tale) Embedding

More information

1 STARTUP Overview Buttons Basics of Control Resetting Faults and Alarms OPERATION...

1 STARTUP Overview Buttons Basics of Control Resetting Faults and Alarms OPERATION... Operation & Service Manual 940126-0002 pco 3 Programmable Logic Controller Contents 1 STARTUP...1 1.1 Overview... 1 1.1.1 Buttons... 1 1.1.2 Basics of Control... 1 1.2 Resetting Faults and Alarms... 2

More information

1. Hardware Bookkeeping & Adjustment...7. Access Flow Chart... 7 System Adjustment... 8 Chance Adjustment... 9 Touch Screen Calibration...

1. Hardware Bookkeeping & Adjustment...7. Access Flow Chart... 7 System Adjustment... 8 Chance Adjustment... 9 Touch Screen Calibration... Table of Contents 1. Hardware...2 Connectors Descriptions... 2 Connecting 2nd Screen and Touch Panel (Optional)... 3 Connection Diagram... 4 DIP Switch Settings... 5 36 & 10 PIN Button Layout... 5 Solving

More information

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1* Safety Manual Process pressure transmitter IPT-1* 4 20 ma/hart Process pressure transmitter IPT-1* Contents Contents 1 Functional safety 1.1 General information... 3 1.2 Planning... 4 1.3 Instrument parameter

More information

ThopEasy + INSTRUCTIONS FOR USE. Precious life Progressive care. Thopaz. Thopaz+

ThopEasy + INSTRUCTIONS FOR USE. Precious life Progressive care. Thopaz. Thopaz+ ThopEasy + INSTRUCTIONS FOR USE Thopaz+ Thopaz Precious life Progressive care Table of contents 1 Requirements... 3 2 Installation of ThopEasy+ on your PC... 4 3 Instructions for use... 5 9 3.1 Start ThopEasy+...

More information

D-Opto Dissolved Oxygen Sensor Operation Manual

D-Opto Dissolved Oxygen Sensor Operation Manual D-Opto Dissolved Oxygen Sensor Operation Manual Software version 2.6 Contents 1. Introduction..... 1 Optical Sensor Technology.... 1 Features...... 1 2. D-Opto Specifications. 2 Specifications... 2 3.

More information

PTG100 Precision Test Gauge

PTG100 Precision Test Gauge PTG100 Precision Test Gauge User Manual PD1007 Rev B 03/28/2014 Palmer Instruments Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free: 800-421-2853 Phone: 828-658-3131 Fax: 828-658-0728 Email:

More information

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008 UNITY 2 TM Air Server Series 2 Operators Manual Version 1.0 February 2008 1. Introduction to the Air Server Accessory for UNITY 2...2 1.1. Summary of Operation...2 2. Developing a UNITY 2-Air Server method

More information

OMNISPORT 2000 SWIMMING QUICK REFERENCE

OMNISPORT 2000 SWIMMING QUICK REFERENCE Before During After OMNISPORT 2000 SWIMMING QUICK REFERENCE 1. Confirm that the timer is reset. 2. Set the timer to the correct event and heat. The right LCD, line 2 displays E:(event) H:(heat) R:(round)

More information

Front-end Realization of ASIC for Traffic Light Control with Real Time Clock Synchronization

Front-end Realization of ASIC for Traffic Light Control with Real Time Clock Synchronization Front-end Realization of ASIC for Traffic Light Control with Real Time Clock Synchronization Mukul Bhargava M.Tech Scholar Deptt. of Elex. & Instr., Shri G.S. Institute of technology, Indore-452003 (M.P.)

More information