These days, I am more involving WAN Ethernet service product which is a bit complicated to
|
|
- Randolph Nicholas Cobb
- 5 years ago
- Views:
Transcription
1 These days, I am more involving WAN Ethernet service product which is a bit complicated to troubleshoot. Simply, tons of vendors and gears in the market. If you are not dealing with those devices all the time, you would spend time to play with some commands until you get output what you want. WAN Ethernet service is very popular in data communication market in compatible price. By comparing to traditional circuit, it is a lot cheaper. Also, H/W cost is cheaper. It dramatically drops your maintenance cost. For those reasons, WAN Ethernet service will get more sunshine in the market. By the way, there are many vendors out there. Seems like major players are Tellabs, Fujitsu, Cisco, Nortel, Ciena Corporation, Overture networks, Anda networks and etc. Here is the basic commands for overture ISG5100 Ethernet Switch for carriers. - To see uptime Overture_ISG5100# uptime 10:40pm up 42 days, 3:03, load average: 0.00, 0.00, / 9
2 - To see all VLAN Overture_ISG5100# port show all vlan Amt Port Type Pvid Pri Only IngF Vlan/Label Cir Burst Flow Pause 2.1 Enet 0 1 off off none N/A N/A N/A N/A 2.2 Enet 0 1 off off none N/A N/A N/A N/A 2.3 Enet 0 1 off off none N/A N/A N/A N/A 2.4 Enet 0 1 off off none N/A N/A N/A N/A 2.5 Enet 0 1 off off none N/A N/A N/A N/A 2.6 Enet 0 1 off off none N/A N/A N/A N/A 2.7 Enet 0 1 off off none N/A N/A N/A N/A 2.8 Enet 0 1 off off none N/A N/A N/A N/A 3.1 OC3 0 1 off off mgmt 1 2 N/A N/A - To show L2 class interface Overture_ISG5100# l2classify show Egress Rate Limt RuleName Pri Port VLAN DSCP Pbit Port Q Action Cir/Burst PBit DSCP OVR any any any PU/ / 100 no no OVR any any PO/ n/a no/ 0 no no - To check a status of port Overture_ISG5100# port show 1.1 status 2 / 9
3 Showing Port status Port Type Admin Oper Duplex Speed AutoNeg Lpbk RxErrTotal 1.1 Enet up up Full 100M n/a disab To see port configuration Overture_ISG5100# port show 1.1 config Admt Dot InFwd Spd Full Auto Port Type Admin Learn Polc Jmbo Only 1p Mode 100M Dup Neg Xovr 1.1 Enet up off off on off off sw/br on on off mdi Overture_ISG5100# - To check VLAN setup Overture_ISG5100# port show 1.1 vlan Amt Port Type Pvid Pri Only IngF Vlan/Label Cir Burst Flow Pause 1.1 Enet 0 1 off off none N/A N/A N/A N/A - To check details of the port Overture_ISG5100# port show 1.1 detail 3 / 9
4 Showing port details Port Type Drops Rx Tx Q Disc Bundle 1.1 Enet N/A - To check detail counters Overture_ISG5100# port show 1.1 detail counters Showing port detailed counters -- Counters for TX_BYTES_GOOD RX_BYTES_GOOD TX_BYTES_TOTAL RX_BYTES_TOTAL TX_UNICAST_PKTS RX_SHORT_PKTS_GOOD TX_MULTICAST_PKTS RX_SHORT_PKTS_BAD TX_BROADCAST_PKTS RX_LONG_PKTS_GOOD TX_PAUSE_PKTS RX_LONG_PKTS_BAD TX_VLAN_PKTS RX_UNICAST_PKTS TX_CRC_ERRS RX_MULTICAST_PKTS TX_DEFERS RX_BROADCAST_PKTS TX_EXCESS_DEFERS RX_PAUSE_PKTS TX_SINGLE_COLS RX_VLAN_PKTS TX_MULTI_COLS RX_CRC_ERRS TX_EXCESS_COLS RX_ALIGN_ERRS TX_LATE_COLS RX_RUNTS TX_NORM_COLS RX_LENGTH_ERRS TX_FIFO_ERRS RX_FALSE_CRS TX_PKTS_ RX_PHY_ERRS TX_PKTS_ RX_FIFO_ERRS TX_PKTS_ RX_IGNORED TX_PKTS_ RX_OPCODE_BAD TX_PKTS_ RX_PKTS_ TX_PKTS_ RX_PKTS_ RX_PKTS_ RX_PKTS_ RX_PKTS_ RX_PKTS_ / 9
5 - To clear PM counters Overture_ISG5100# port clear 1.1 pm-counters - To see PM result, only apply serial link not Ethernet. Overture_ISG5100# port show 3.1 pm Showing PM Counters Port Type Section ES SES SEFS CV Port Type Line ES SES CV UAS Port Type FarendLine FEES FESES FESCV FEUAS Port Type Path ES SES CV UAS Port Type FarendPath FEES FESES FECV FEUAS Overture_ISG5100# - To see queues Overture_ISG5100# port show all detail queues 5 / 9
6 Port Type Cntr Queue0 Queue1 Queue2 Queue3 Queue4 Queue5 Queue6 1.1 GigSFP Bytes Pkts OC3 Bytes Pkts To see errors on the interface Overture_ISG5100# port show 1.1 errors Showing Port Errors Port Type RxCrc RxAlign RxRunt RxLength RxCrs RxPhy RxFifo 1.1 Enet To see live traffic on the link, default interval is 5 sec Overture_ISG5100# port show 1.1 util Per Second Utilization for Port(s) 1.1 Count=0 DisplayTime=5 Secs Port Type TxPkts RxPkts TxBits RxBits Tx % Rx % 1.1 Enet Kbps Mbps Port Type TxPkts RxPkts TxBits RxBits Tx % Rx % 1.1 Enet Kbps Mbps To see log for alrams 6 / 9
7 Overture_ISG5100# log show alarm Aug 13 19:31:53 isg5000 isgservices: FAULT TIME="Thu Aug 13 19:31: " SEVERITY="Major" SLOT="Slot 3" DEVICE="port 1" ID="Section Loss of Frame (LOF)" SEQUENCE NUMBER="1" Aug 13 19:31:54 isg5000 isgservices: FAULT TIME="Thu Aug 13 19:31: " SEVERITY="Cleared" SLOT="Slot 3" DEVICE="port 1" ID="Section Loss of Frame (LOF)" SEQUENCE NUMBER="2" Aug 13 19:33:12 isg5000 isgservices: FAULT TIME="Thu Aug 13 19:33: " SEVERITY="Critical" SLOT="Slot 1" DEVICE="port 1" ID="Link failure" SEQUENCE NUMBER="3" Aug 13 19:34:36 isg5000 isgservices: FAULT TIME="Thu Aug 13 19:34: " SEVERITY="Cleared" SLOT="Slot 1" DEVICE="port 1" ID="Link failure" SEQUENCE NUMBER="4" Aug 13 19:34:49 isg5000 isgservices: FAULT TIME="Thu Aug 13 19:34: " SEVERITY="Critical" SLOT="Slot 1" DEVICE="port 1" ID="Link failure" SEQUENCE NUMBER="5" Aug 13 19:45:37 isg5000 isgservices: FAULT TIME="Thu Aug 13 19:45: " SEVERITY="Cleared" SLOT="Slot 1" DEVICE="port 1" ID="Link failure" SEQUENCE NUMBER="6" Aug 13 19:46:37 isg5000 isgservices: FAULT TIME="Thu Aug 13 19:46: " SEVERITY="Critical" SLOT="Slot 1" DEVICE="port 1" ID="Link failure" SEQUENCE NUMBER="7" - To see log for command history Overture_ISG5100# log show command Sep 1 12:48:10 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show all vlan" Sep 1 12:52:40 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show 1.1 status" Sep 1 12:52:56 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show 1.1 detail" Sep 1 12:52:58 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show 1.1 detail" Sep 1 12:53:16 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show 1.1 detail counters" Sep 1 12:54:12 isg5000 cli_sh: CLI USER="AshburnCMC" 7 / 9
8 IP_ADDR=" " CMD="port show 1.1 detail counters" Sep 1 12:54:13 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show 1.1 status" Sep 1 12:54:18 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show 1.1 status" Sep 1 12:54:40 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show 1.1 counters " Sep 1 12:54:52 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show 1.1 detail" Sep 1 12:54:57 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show 1.1 detail counters" Sep 1 12:55:09 isg5000 cli_sh: CLI USER="AshburnCMC" IP_ADDR=" " CMD="port show 1.1 status" : : - To see all config Overture_ISG5100# show status - To see start configuration Overture_ISG5100# config show 8 / 9
9 9 / 9
PTP 800 SPLIT-MOUNT SOLUTION
TM PTP 800 SPLIT-MOUNT SOLUTION LICENSED ETHERNET MICROWAVE FOR MULTI-SERVICE NETWORKS Cambium Point-to-Point (PTP) 800 Licensed Ethernet Microwave Solutions can efficiently and affordably transport the
More informationConfiguring Bidirectional Forwarding Detection for BGP
CHAPTER 7 Configuring Bidirectional Forwarding Detection for BGP This chapter describes how to configure Bidirectional Forwarding Detection (BFD) for BGP. This chapter includes the following sections:
More informationImplementing BFD. BFD over Bundle. Enabling BFD Sessions on Bundle Members SUMMARY STEPS DETAILED STEPS
Bidirectional forwarding detection (BFD) provides low-overhead, short-duration detection of failures in the path between adjacent forwarding engines. BFD allows a single mechanism to be used for failure
More informationMOTOROLA PTP 800 LICENSED ETHERNET MICROWAVE
HIGH-THROUGHPUT COMMUNICATIONS FOR MULTI-SERVICE NETWORKS MOTOROLA PTP 800 LICENSED ETHERNET MICROWAVE PTP 800 solutions can efficiently and affordably transport the data, voice and video that your bandwidth-intensive
More informationSession Objectives. At the end of the session, the participants should: Understand advantages of BFD implementation on S9700
BFD Features Session Objectives At the end of the session, the participants should: Understand advantages of BFD implementation on S9700 Understand when to use BFD on S9700 1 Contents BFD introduction
More informationProduct Overview. Product Description CHAPTER
CHAPTER 1 This chapter provides a functional overview of the Cisco Redundant Power System 2300 and covers these topics: Product Description, page 1-1 Features, page 1-3 Supported Devices, page 1-4 Deployment
More informationAirflow Options for Cisco MDS 9396S SAN Switch
Airflow Options for Cisco MDS 9396S SAN Switch This document describes how to configure, administer and troubleshoot airflow options in the MDS 9396S switch. Anyone can use this document along with hardware
More informationQuickstart Installation Checklist (Please refer to operation manual for complete installation instructions)
Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions) 1. Uncrate blender from packaging. 2. Lift the blender and position over machine throat or floor
More informationDomino DUEMMEGI. Domino. Communication Interface DFTS User s Manual. Release September 2007
Domino Domino Communication Interface DFTS User s Manual Release 2.3 - September 2007 srl Via Longhena 4-20139 MILANO Tel. 02/57300377 - FAX 02/55213686 Domino - DFTS: User s Manual R.2.3 Index 1- INTRODUCTION...3
More informationTechnical Bulletin, Communicating with Gas Chromatographs
Last Updated: 13- July-2010 TB-080000C Technical Bulletin, Communicating with Gas Chromatographs OMNI FLOW COMPUTERS, INC. 12620 West Airport Boulevard, Suite 100 Sugar Land, Texas 77478 United States
More informationSCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual
SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel DTLS Manual This document contains proprietary information. Copyright 2015 Scientific Data Systems, Inc. All rights reserved. 1 Depth Tension
More informationUG4: OPEN HAB. Elelabs ZigBee RPi Shield firmware version, referenced in this guide: OpenHab2 software version, referenced in this guide: v2.3.
UG4: OPEN HAB This document describes how to use Elelabs ZigBee RPi Shield (https://elelabs.com/products/elelabs_zigbee_shield.html) with existing Home Automation platform called OpenHAB (https://www.openhab.org/).
More informationHART Communications Board
- HART Communications Board (Highway Addressable Remote Transducer) User Manual Document No. Sensidyne, LP. 1000 112 th Circle N, Suite 100 St. Petersburg, Florida 33716 USA 800-451-9444 +1 727-530-3602
More informationDoc. no.dit om005 PRODUCT NAME. IO-Link/ELECTRO-PNEUMATIC REGULATOR. MODEL / Series / Product Number ITV*0*0-IO****-X395
Doc. no.dit-69900-om005 PRODUCT NAME IO-Link/ELECTRO-PNEUMATIC REGULATOR MODEL / Series / Product Number ITV*0*0-IO****-X395 This is the operation manual for the IO-Link compliant ITV. For other contents
More informationBidirectional Forwarding Detection Routing
This chapter describes how to configure the ASA to use the Bidirectional Forwarding Detection (BFD) routing protocol. About BFD Routing, page 1 Guidelines for BFD Routing, page 5 Configure BFD, page 5
More informationMP15 Jockey Pump Controller
Setup and Operating Instructions MP15 Jockey Pump Controller This manual provides general information, installation, operation, maintenance, and system setup information for Metron Model MP15 Jockey Pump
More informationAir Bubbler Depth Gauge DG2200 Installation and Reference Manual
Air Bubbler Depth Gauge DG2200 Installation and Reference Manual Rev. 3.2.2 06/2011 Installation and Reference Manual Page 2 Contents Chapter 1: Installation and Overview... 3 1.1 DG2200 Location Diagram...
More informationStand-Alone Bubble Detection System
Instruction Sheet P/N Stand-Alone Bubble Detection System 1. Introduction The Bubble Detection system is designed to detect air-bubble induced gaps in a bead of material as it is being dispensed. When
More informationSteelHead Interceptor Appliance Installation Guide. Version 5.0 July 2015
SteelHead Interceptor Appliance Installation Guide Version 5.0 July 2015 2015 Riverbed Technology, Inc. All rights reserved. Riverbed and any Riverbed product or service name or logo used herein are trademarks
More informationAPPENDIX 10, Automation Standard
APPENDIX 10, Automation Standard to Arla Foods Group Agreement for Purchase of Machinery including installation Software Design Specification Seller (company) Document responsible (Seller) Description
More informationDatasheet: K-30 ASCII Sensor
Datasheet: K-30 ASCII Sensor The K30 ASCII sensor is a low cost, infrared and maintenance free transmitter module intended to be built into different host devices that require CO2 monitoring data. The
More informationPressure Automated Calibration Equipment
GE Measurement & control Pressure Automated Calibration Equipment Safety Instructions and User Guide - K0447 PACE5000 PACE6000 K0447 Issue No. 9 1 10 1 PACE5000 1 2 3 4 5 PACE6000 2 6 7 8 3 4 5 6 7 8 9
More informationDigi Connect ME 9210 Linux: serial port 2 for JTAG modules
Digi Connect ME 9210 Linux: serial port 2 for JTAG modules Document History Date Version Change Description 08/05/2009 Initial entry/outline Table of Contents Document History... 2 Table of Contents...
More informationLENNOX SLP98UHV DIAGNOSTIC CODES
Code Status of Equipment Action required to clear and recover - Idle mode (Decimal blinks at 1 Hertz -- 0.5 second ON, 0.5 second OFF) A Cubic feet per minute (cfm) setting for indoor blower (1 second
More informationUser manual CF8-D/W-IN
User manual CF8-D/W-IN General The sensor CF8-D/W-IN is used to measure the carbon dioxide concentration inside incubators. All functions can be modified from a PC with the communication cable. UMA 48
More informationDigi Connect ME 9210 Linux: 2 nd serial over FIM
Digi Connect ME 9210 Linux: 2 nd serial over FIM Document History Date Version Change Description 09/04/2009 Initial entry/outline Table of Contents Document History... 2 Table of Contents... 2 1 Problem
More informationBasic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual
Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values Operations Manual Please read, understand, and follow these instructions before operating this equipment.
More informationPage 2 of 46 Prepared by: Engr. Ram Sankar
Page 2 of 46 CHAPTER 1 GETTING STARTED Page 3 of 46 Establishing Communication with Relay: 1. Open MICOM S1 studio and click on NEW SYSTEM. 2. Name it and save on desired location and click on OK. Page
More informationTECNAUTIC_GmbH. Display Functions with the PB100/200 connected: -- GND Speed -- GND Course -- Heading (Gyro option is recommended) 2 m
PB100/200 Sonic Wind Wind, GPS, Compass Display Config: SE=12 di=00 df=20,91,30,34,(61) 35,36,81 Gr=01 n0=00 n1=07 n2=07**) n3=00 Display Functions with the PB100/200 connected: -- Apparent Wind -- True
More informationHOT SPOT MONITOR (HSM)
HOT SPOT MONITOR (HSM) EDS FILE TECHNICAL NOTE INSERTING EDS TO ROCKWELL STUDIO 5000 Follow the below steps to add GraceSense TM Hot Spot Monitor (HSM) product via Ethernet IP to your project. Download
More information*24 RF HOUSE ID CODE [00] 00 = Disable all wireless touchpad usage = using 5827 or 5827BD touchpad
PROGRAMMING FORM Local programming requires the use of a 2-line Alpha keypad connected to partition 1 keypad terminals on the control. NOTE: For UL installations, the system may be configured as a single
More informationRace Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock
Eliminator Competition Stand Alone Mode - Instruction Manual Main Menu: After startup, the Eliminator Competition will enter the Main Menu. Press the right/left arrow buttons to move through the menu.
More informationT i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)
RACEAMERICA T i m i n g S y s t e m s Demo Tree Controller Owner s Manual Models 3204D, 3204DW & 3204DX Rev D RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA 95055-3469 (408) 988-6188 http://www.raceamerica.com
More informationResidential Ultrasonic Gas Meters
Residential Ultrasonic Gas Meters Published in Electronics and Telecommunications (ISETC), 2014 11th International Symposium on DOI: 10.1109/ISETC.2014.7010758 pp. 101-105 Laurentiu Gavra Timişoara, Romania
More informationTHE MERTON GROUP. Municipal Broadband Networks Infrastructure Merrimack, NH. The Merton Group Copyright The Merton Group, LLC Page 1
THE MERTON GROUP Municipal Broadband Networks Infrastructure Merrimack, NH The Merton Group Copyright The Merton Group, LLC Page 1 Methodology The Merton Group Copyright The Merton Group, LLC Page 2 Commence
More informationSTAND alone & p.c. VERSION
STAND alone & p.c. VERSION ECONOMY TRACK SYSTEMS 1/4 & 1/8 Mile Asphalt Track Dirt / Sand Track Mud Track Snowmobile Track R/C Car Track Custom Track Systems Timing to.001 Accuracy Time Slip Printer Optional
More informationCUSTOMER INFORMATION
CUSTOMER INFORMATION COMPANY NAME & ADDRESS: CONTACT: PHONE: FAX: NOTES: DATE ENTERED: DATE MODIFIED: 05/2/28 11:10 A 11/5/2010 11:17 A COMMENTS 1: COMMENTS 2: Vista20P-9(IP) PROGRAMMING FORM Local programming
More informationCryostream 800 Series
Cryostream 800 Series Cryostream 800 Series Nearly 30 years after the invention of the first Cryostream Cooler, Oxford Cryosystems is proud to announce the launch of the new 800 series Cryostream. The
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationSteelHead SaaS User s Guide
SteelHead SaaS User s Guide RiOS Version 9.6 March 2017 2017 Riverbed Technology, Inc. All rights reserved. Riverbed and any Riverbed product or service name or logo used herein are trademarks of Riverbed.
More informationHow to use Bidirectional Forwarding Detection(BFD) in NetScaler?
How to use Bidirectional Forwarding Detection(BFD) in NetScaler? Bidirectional Forwarding Detection commonly referred as BFD is a simple hello protocol that provides fast failure detection mechanism between
More informationIn Vivo Scientific, LLC INSTRUCTION MANUAL
CO 2 Controller In Vivo Scientific, LLC INSTRUCTION MANUAL CONTENTS CONTENTS...1 ABOUT THIS MANUAL...2 INTRODUCTION...2 Cautions and Warnings...2 Parts List...2 Unpacking...2 INSTRUMENT DESCRIPTION...3
More informationAutopilot setup. VRF (Virtual Rudder Feedback) calibration. Software setup NSS evo2 Installation Manual
Autopilot setup Verifying the autopilot connection When an AC12N, AC42N, or SG05 is connected to the NSS evo2 system, the NSS evo2 will automatically detect the autopilot and an Autopilot menu icon will
More informationManual Weighingblock VB2 series and Uniscale
Manual Weighingblock VB2 series and Uniscale Note: At page 8 in this manual you will find a short form instruction. Normally the only instruction shipped together with the Scale. Overview different ranges.
More informationUser Manual MFCS TM -EZ
User Manual MFCS TM -EZ Version 6A_December 2016 1. INTRODUCTION 5 2. GENERAL INFORMATION 6 2.1 General functioning 6 2.2 Different MFCS TM 6 3. PACKAGE CONTENT 8 4. MFCS TM -EZ DESCRIPTION 9 5. CONNECTIONS
More informationXC2 Client/Server Installation & Configuration
XC2 Client/Server Installation & Configuration File downloads Server Installation Backup Configuration Services Client Installation Backup Recovery Troubleshooting Aug 12 2014 XC2 Software, LLC Page 1
More informationTHE MERTON GROUP. Municipal Broadband Networks Infrastructure Princeton, MA. The Merton Group Copyright The Merton Group, LLC Page 1
THE MERTON GROUP Municipal Broadband Networks Infrastructure Princeton, MA The Merton Group Copyright The Merton Group, LLC Page 1 Methodology The Merton Group Copyright The Merton Group, LLC Page 2 Commence
More informationRcvr-Acct#: Date: May 3, :31 AM
32P1-5 PROGRAMMING FORM Local programming requires the use of a 2-line Alpha keypad connected to partition 1 keypad terminals on the control. NOTE: For UL installations, the system may be configured as
More informationISU 2x64 Dual Port ISDN Service Unit User Manual
ISU 2x64 Dual Port ISDN Service Unit User Manual Part Numbers 1200051L1 1200051L2 1200051L5 1200051L6 U-Interface Version, 110 VAC S/T-Interface Version, 110 VAC S/T-Interface International, 110 VAC S/T-Interface
More informationOperating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com
Operating Manual Software for Fire and Gas Warning Units Order No.: 10154656/01 MSAsafety.com MSA Europe GmbH Schlüsselstrasse 12 8645 Rapperswil-Jona Switzerland info.ch@msasafety.com www.msasafety.com
More informationPRODUCT MANUAL. Diver-MOD
PRODUCT MANUAL Diver-MOD Contents 1 Introduction... 1 1.1 Scope and Purpose... 1 1.2 Features... 1 1.3 System Overview... 1 1.4 Specifications... 2 2 Getting Started... 2 2.1 Supported Equipment... 2 2.2
More informationLT GasAnalyzer. LT GasAnalyzer Page 1 of 6
LT GasAnalyzer LT GasAnalyzer Page 1 of 6 LT GasAnalyzer Disturbances in the protective gas supply can cause production losses or affect product quality. In the worst case, it even can endanger life and
More informationThe HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.
The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is
More informationSafety Manual VEGAVIB series 60
Safety Manual VEGAVIB series 60 Contactless electronic switch Document ID: 32002 Contents Contents 1 Functional safety... 3 1.1 General information... 3 1.2 Planning... 4 1.3 Adjustment instructions...
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationCNC Communication Protocol
CNC Communication Protocol Commands and Serial/Discrete Signals for the XPR Cutting System 809810 Revision 3 January 2018 CNC Communication Protocol for the XPR Cutting System 1 Contents Before you begin...
More informationSurge suppressor To perform its intended functions, an AEI site must have the components listed above and shown in Fig. 4.1.
4.0 COMPONENT FEATURES AND REQUIREMENTS An AEI site should include the following component subsystems: Presence detector Wheel detector Tag reader Controller Communications Power supply Surge suppressor
More informationDrag racing system HL190 User Manual and installation guide
Drag racing system HL190 User Manual and installation guide Version 10/2015 TAG Heuer Timing Page 1 / 14 1. Global This software controls the whole Drag racing installation HL190. Combined with the Chronelec
More informationPanther 5 Acute Care Ventilator
1 HIGHLIGHTS High performance and advanced features target the ICU environment Utilizes an internal blower with a specially designed flow control valve removing the need for using compressed air without
More informationCOMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x
Electrical Installation Requirements Care should be taken to separate the power and signal cables to prevent electrical interference and possible damage due to inadvertent connection. SUPPLY E L N LN2
More informationCertification Exhibit FCC ID: R7PIWRS4. FCC Rule Part: ACS Report Number: W03.11.A
Certification Exhibit FCC ID: R7PIWRS4 FCC Rule Part: 15.247 ACS Report Number: 09-0412.W03.11.A Manufacturer: Cellnet Technology Inc. Model: Gridstream DCIWR Manual 5015 B.U. Bowman Drive Buford, GA 30518
More informationsecuring networks with silicon
NITROX II A Family of In-line Security Processors Presented by: Muhammad Raghib Hussain Contributed by: Bob Sanzone, Dan Katz, David Asher, David Carlson, Gregg Bouchard, Michael Bertone, Muhammad Hussain,
More informationACI_Release_Notes.txt VERSION Fixed Tank info for ELITE in Dive section 2. Fixed USB port initializing for old DC VERSION
VERSION 2.4.0 1. Fixed Tank info for ELITE in Dive section 2. Fixed USB port initializing for old DC VERSION 2.3.9 1. Fixed Dive Computer configuration section error 2. Fixed message for download/upload
More informationμsmartdigi Presented at Ham-Com 2008 Plano Texas June 2008 by Rich Painter, AB VO Painter Engineering, Inc.
μsmartdigi Presented at Ham-Com 2008 Plano Texas 13-14 June 2008 by Rich Painter, AB VO Painter Engineering, Inc. μsmartdigi μsmartdigi APRS Digipeater μsmartdigi New Features If time permits... μsmartdigi
More informationCMC Peer-to-Peer Control System Software. User s Manual Version 1.0
CMC Peer-to-Peer Control System Software User s Manual Version 1.0 2 22562920 Rev. 03 Date of Issue: 6/12/07 PREFACE Information and Illustrations Information and illustrations are not binding. Ingersoll-Rand
More informationSAUTER flexotron 800 heating. List of network variables for Modbus communication. Manual P A P
SAUTER flexotron 800 heating List of network variables for communication Manual P100013118 A P100012094 2/90 P100013118 A Content Content 1 General notes 5 1.1 Disclaimer 5 1.2 Trademarks 5 2 Preface 7
More informationTimex Ironman Run Trainer Powered by GPS Technology
Timex Ironman Run Trainer Powered by GPS Technology Pace and distance powered by GPS gives you the freedom to run anywhere. No more tracks, treadmills or repetitive loops to calculate distance. Just start
More informationThe Universal Translator
The Universal Translator David Cornfield dcornfield@apm.com Accellera Systems Initiative 1 Traditional Agents A Agent A Agent Chip ~ s m d A ~ s m d A B Agent B Agent m ~ s d B m ~ s d B Unit Level Chip
More information1. Hardware Bookkeeping & Adjustment Access Flow Chart... 6 System Adjustment... 7 Chance Adjustment... 8 Touch Screen Calibration...
Table of Contents 1. Hardware... 2 Connectors Descriptions... 2 Connection Diagram... 3 DIP Switch Settings... 4 36 & 10 PIN Button Layout... 4 Solving Hopper SSR Error... 5 2. Bookkeeping & Adjustment...
More informationUE- 90- X X X X X X O P E R AT I N G M A N UA L 0 TO 90 HYDRAULIC UPENDER
UE- 90- X X X X X X O P E R AT I N G M A N UA L ADDRESS 2230 Brush College Road Decatur, IL 62526 Phone: 217-423-6001 Fax: 217-422-1049 E-mail: sales@alignprod.com www.alignproductionsystems.com UE-90-XXXXXX
More informationTYPE APPROVAL CERTIFICATE
Page 1 / 4 Certificate number: 23445/A0 BV File number: AP 4160 Product code: 4440I This certificate is not valid when presented without the full attached schedule composed of 7 sections www.veristar.com
More informationManual Leveling Control Installation/Operation
ELECTROMECHANICAL TRIM TAB SYSTEMS Manual Leveling Control Installation/Operation Linear Devices Corporation dba Lectrotab 11126 Air Park Road, Suite G Ashland, VA 23005 www.lectrotab.com Phone: 804-368-8428
More informationDesign Envelope Booster. Sequence of operation
Design Envelope Booster Sequence of operation File No: 62.835 Date: february 11, 2015 Supersedes: 62.835 Date: july 11, 2014 sequence of operation Design Envelope Booster 2 general The packaged domestic
More informationTOSVERT VF-FS1 series APOGEE FLN option unit Function Manual APG002Z NOTICE
TOSVERT VF-FS1 series APOGEE FLN option unit Function Manual APG002Z NOTICE 1. Make sure that this instruction manual is delivered to the end user of APOGEE FLN option unit. 2. Read this manual before
More informationSeries 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST)
Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST) Application Positioner firmware for early detection of control valve faults giving maintenance recommendations. Valid
More informationWhite Rabbit Applications for Data Acquisition Systems
White Rabbit Applications for Data Acquisition Systems Dimitris Lampridis CERN BE-CO Hardware and Timing section DAQ Meeting, IN2P3, 01 June 2016 Dimitris Lampridis WR in DAQ 1/36 1 White Rabbit 2 WR Demo
More information2. USER INSTRUCTION. Table of contents: Pg.1/14 N:\FAP-2000: LWP
Pg.1/14 2. USER INSTRUCTION. Table of contents: 2.1 SHORT PANEL DESCRIPTION...... Pg.2 2.2 AUTOPILOT TAKE-OVER & MODE SELECTION....... Pg.3 2.3 AUTOPILOT FUNCTIONS....... Pg.3 2.4 THE SPECIAL FUNCTION
More informationwith O 2 Controller Instruction Manual
14500 Coy Drive, Grass Lake, Michigan 49240 734-475-2200 E-mail: sales@coylab.com www.coylab.com Hypoxic Cabinets (In-Vivo / In-Vitro) with O 2 Controller Instruction Manual Index Page Warranty 2 Warnings
More informationDevice Description User Manual Logix 520MD Positioners
Device Description User Manual Logix 520MD Positioners GENERAL INFORMATION... 3 INTRODUCTION... 3 QUALIFIED PERSONNEL... 3 USING THIS DOCUMENT... 3 TERMS CONCERNING SAFETY... 3 1 STATUS... 4 1.1 CMD SOURCE...
More information1. Hardware Hardware Connection... 2 Connection Diagram... 3 DIP Switch Settings & 10 PIN Button Layout... 4
Table of Contents 1. Hardware... 2 Hardware Connection... 2 Connection Diagram... 3 DIP Switch Settings... 4 36 & 10 PIN Button Layout... 4 2. Bookkeeping & Adjustment... 5 Access Flow Chart... 5 System
More informationAstral in AirView: Improving patient care through connectivity. ResMed.com
Astral in AirView: Improving patient care through connectivity ResMed.com Using Astral in AirView via the ResMed Connectivity Module (RCM) Astral is ResMed s portable, invasive and non-invasive life support
More informationSIDRA INTERSECTION 6.1 UPDATE HISTORY
Akcelik & Associates Pty Ltd PO Box 1075G, Greythorn, Vic 3104 AUSTRALIA ABN 79 088 889 687 For all technical support, sales support and general enquiries: support.sidrasolutions.com SIDRA INTERSECTION
More informationIntegrate Riverbed SteelHead. EventTracker v8.x and above
EventTracker v8.x and above Publication Date: March 27, 2018 Abstract This guide provides instructions to configure a Riverbed SteelHead to send its syslog to EventTracker Enterprise Scope The configurations
More informationMonsoon3V+ Multiple Pump VFD Control System. Please pass these instructions on to the operator of this equipment.
Monsoon3V+ Multiple Pump VFD Control System Please pass these instructions on to the operator of this equipment. INTRODUCTION MONSOON 3V+ Pump Controller The MONSOON 3V+ pump control system is a fully
More informationThis Manual Part recommends functional/operating guidelines for control of automatic grade crossing warning systems. Draft
Recommended Functional/Operating Guidelines for Control of Automatic Grade Crossing Warning Systems Revised 2017 (6 Pages) A. Purpose This Manual Part recommends functional/operating guidelines for control
More informationPaper Presentation: COMPLETE AND SIMULTANEOUS DCS FAILURE IN TWO 500MW UNITS
INDIAN POWER STATIONS POWER PLANT O&M CONFERENCE - 2012 Paper Presentation: COMPLETE AND SIMULTANEOUS DCS FAILURE IN TWO 500MW UNITS K C Tripathy, DGM (C&I) Anoop K, Dy Manager (C&I) B K Rathore, Dy Manager
More informationSteelHead SD Installation Guide
SteelHead SD Installation Guide Models 570-SD, 770-SD, 3070-SD SteelConnect 2.5, RiOS 9.2.1-cf1 November 2016 2018 Riverbed Technology, Inc. All rights reserved. Riverbed and any Riverbed product or service
More informationA4021 Series VALVE PROVING SYSTEM
UNIVERSA GAS VAVES A4021 Series VAVE PROVING SYSTEM APPICATION PRODUCT HANDBOOK The A4021 is a self--checking microprocessor based Valve Proving System (VPS). The A4021 checks the effective closure of
More informationBASnet LightiView Install Guide
BASnet LightiView 1025 Cobb Place Blvd Suite 100 Kennesaw, GA 30144 800-241-9173 www.triateklighting.com ATTENTION This section serves as a notice of the immediate or potential dangers involved when working
More informationA4s Operation Manual
A4s Operation Manual Safety Instruction Please read this manual carefully, also with related manual for the machinery before use the controller. For installing and operating the controller properly and
More informationInstrument pucks. Copyright MBARI Michael Risi SIAM design review November 17, 2003
Instrument pucks Michael Risi SIAM design review November 17, 2003 Instrument pucks Pucks and Plug-and-Work The MBARI puck prototype Puck software interface Pucks in practice (A Puck s Tale) Embedding
More information1 STARTUP Overview Buttons Basics of Control Resetting Faults and Alarms OPERATION...
Operation & Service Manual 940126-0002 pco 3 Programmable Logic Controller Contents 1 STARTUP...1 1.1 Overview... 1 1.1.1 Buttons... 1 1.1.2 Basics of Control... 1 1.2 Resetting Faults and Alarms... 2
More information1. Hardware Bookkeeping & Adjustment...7. Access Flow Chart... 7 System Adjustment... 8 Chance Adjustment... 9 Touch Screen Calibration...
Table of Contents 1. Hardware...2 Connectors Descriptions... 2 Connecting 2nd Screen and Touch Panel (Optional)... 3 Connection Diagram... 4 DIP Switch Settings... 5 36 & 10 PIN Button Layout... 5 Solving
More informationSafety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*
Safety Manual Process pressure transmitter IPT-1* 4 20 ma/hart Process pressure transmitter IPT-1* Contents Contents 1 Functional safety 1.1 General information... 3 1.2 Planning... 4 1.3 Instrument parameter
More informationThopEasy + INSTRUCTIONS FOR USE. Precious life Progressive care. Thopaz. Thopaz+
ThopEasy + INSTRUCTIONS FOR USE Thopaz+ Thopaz Precious life Progressive care Table of contents 1 Requirements... 3 2 Installation of ThopEasy+ on your PC... 4 3 Instructions for use... 5 9 3.1 Start ThopEasy+...
More informationD-Opto Dissolved Oxygen Sensor Operation Manual
D-Opto Dissolved Oxygen Sensor Operation Manual Software version 2.6 Contents 1. Introduction..... 1 Optical Sensor Technology.... 1 Features...... 1 2. D-Opto Specifications. 2 Specifications... 2 3.
More informationPTG100 Precision Test Gauge
PTG100 Precision Test Gauge User Manual PD1007 Rev B 03/28/2014 Palmer Instruments Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free: 800-421-2853 Phone: 828-658-3131 Fax: 828-658-0728 Email:
More informationUNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008
UNITY 2 TM Air Server Series 2 Operators Manual Version 1.0 February 2008 1. Introduction to the Air Server Accessory for UNITY 2...2 1.1. Summary of Operation...2 2. Developing a UNITY 2-Air Server method
More informationOMNISPORT 2000 SWIMMING QUICK REFERENCE
Before During After OMNISPORT 2000 SWIMMING QUICK REFERENCE 1. Confirm that the timer is reset. 2. Set the timer to the correct event and heat. The right LCD, line 2 displays E:(event) H:(heat) R:(round)
More informationFront-end Realization of ASIC for Traffic Light Control with Real Time Clock Synchronization
Front-end Realization of ASIC for Traffic Light Control with Real Time Clock Synchronization Mukul Bhargava M.Tech Scholar Deptt. of Elex. & Instr., Shri G.S. Institute of technology, Indore-452003 (M.P.)
More information