Drag racing system HL190 User Manual and installation guide

Size: px
Start display at page:

Download "Drag racing system HL190 User Manual and installation guide"

Transcription

1 Drag racing system HL190 User Manual and installation guide Version 10/2015 TAG Heuer Timing Page 1 / 14

2 1. Global This software controls the whole Drag racing installation HL190. Combined with the Chronelec Elite V3 software, manage your complete championship. Manage 2 lane with up to 4 light trees (2 for each lane) Generate different light sequences : - Sportsman tree - Pro Tree - Custom (set your own sequence) - Random sequence between 0,2 and 3 sec Use a remote display for spectators Manage Jump starts and reaction time Manage up to 2 timing devices Chronoprinter 540 or 545 over Network TAG Heuer Timing Page 2 / 14

3 1. Software - Menu presentation 1.1. The Interface Information Datagrid displays : Bib number Official Start time Driver/Rider Start time Reaction time Real time Light status START Light sequence RESET System (switches all remaining lights OFF) 1. SETTINGS Menu to connect Light tree, Timing device and Modulo Displays 2. OPTION Option to connect our Modulo display HL950 as Jump start display Print run displayed in datagrid as a pdf file Reset and empty datagridview 3.? About version information and access to user manual TAG Heuer Timing Page 3 / 14

4 2. Hardware presentation 1.1 The light tree 17cm Pre-stage / Stage 3 Amber starting lights 100cm Green (start) light Red light (Jump start) The Christmas tree is direct powered by the control box 1.2 The control Box TOP VIEW light power supply right lane light control left lane light control TAG Heuer Timing Page 4 / 14

5 SIDE VIEW right lane left lane staging beams sockets Pre-Stage Stage Pre-Stage Stage BOTTOM VIEW 230V 50Hz socket serial I/O RS232 socket to computer impulse output socket to Chronoprinter 540/545 TAG Heuer Timing Page 5 / 14

6 1.3 Staging beams The staging beams are mounted on a special bracket which respects the 7 distance for each detector. Pre-stage and stage beam are crossing the track, 7 inches apart. The beams are mounted at 2 inches about the track surface and broken by the cars front tyre. Ensure that the beams and reflector are correctly aligned. 6 inches 2 inches Max 10 meter (33 ft) When the wheels cross the first beam, the Pre-Stage signal will light like the NHRA christmas tree: 14cm 14cm Pre-Stage beam: A light beam-to-photocell connection in each lane that triggers the small pre-stage lights atop the Christmas Tree. The pre-stage lights signal to drivers that they are close to staging, approximately seven inches behind the starting line. TAG Heuer Timing Page 6 / 14

7 When the wheels cross both beams, all lights are ON The vehicle is staged If the vehicle is deep staged, following sign will blink on corresponding lane. This occurs no incidence on the timekeeping. TAG Heuer Timing Page 7 / 14

8 3. Get started This software runs only with Ethernet connection in parallel of a timekeeping software. We recommend to use a (Gigabit) switch in order to connect the Chronoprinter on the network. A. Launch the software 1. Connect your timing devices Use an Ethernet cable to connect the Chronoprinter 540 or 545 on your network. Ensure that all IP address are on the same gateway and no double IPs are in conflit. Enter the IP address of your device (default address is ) Click on connect. Until the socket is open and the printer of your CP540/545 switched on, a confirmation message will be printed. Set the trigger information of the timing photocells (we recommend to use the HL2-31 or HL2-35) Set the input information into which channel the Christmas tree signal has been connected. That s the Green light trigger 2. Connect the Christmas tree and the control box Connect the Christmas tree on the control box (power + data). The control box is driven by a serial communication port RS232. All available COM port will be listed. Select correct COM port and click Connect Start Lights. The control box gives an acknowledge and will confirm the communication status. TAG Heuer Timing Page 8 / 14

9 3. Connect your Jump start Modulo HL950 Connect the Modulo over RS232 or RS485 (please refer to Modulo display user manual). Even our radio HL675 could be connected directly on your laptop. All available COM port will be listed. Select correct COM port and click Connect. You can select the image to display in case of jump start. The image will be the same for both lanes. Then enter the serial number of the Modulo Display which will be for each lane. TAG Heuer Timing Page 9 / 14

10 B. Elite V3 setup Elite V3 should run on the same network as the Christmas tree controller. Connect your device over TCP and select the Chronoprinter 540 protocol (the same as the CP545). The race settings are as you connect all device like or as in our example bellow: LANE 1 (left) LANE 2 (right) TAG Heuer Timing Page 10 / 14

11 For the speed, just set the channel and distance between both photocells for each lane You can change field text in SETTINGS OPTIONS EDIT - Edit intermediate fields text For more informations, please consult Elite V3 user manual. TAG Heuer Timing Page 11 / 14

12 4. Other features A. Extended display If you run an extended windows display. This signal can be converted to Analogic or digital with a special converter and be broadcasted on several TVs around the track or a video wall All timing information will be displayed. You can even customize your screen with 3 different logo. All *.jpg, *.png files are accepted and auto-sized to fit on the screen. B. Export to pdf Creates a printable pdf file of your datagrid. Hands on: You can copy the complete grid to a Excel worksheet. Click on the top left hand corner in order to select the complete grid. Hit Control + V Key in order to copy. Control + C to paste in your excel. C. Clear Datagrid TAG Heuer Timing Page 12 / 14

13 5. Technical Specification To be completed Control Box - Power supply: 110/230V 50/60 Hz - Christmas tree Power supply: 12V 10A included in control box Warranty : One year after delivery of your purchase The warranty is null and void under the following conditions: - Poor maintenance and obvious physical damage - Input or Outputs damaged by poor connection - If the device was opened without factory authorization TAG Heuer Timing Page 13 / 14

14 TAG Heuer PROFESSIONAL TIMING 6A Louis-Joseph Chevrolet 2300 la Chaux-de-Fonds Switzerland Tel : Fax : info@tagheuer-timing.com Http: // TAG Heuer Timing Page 14 / 14

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock Eliminator Competition Stand Alone Mode - Instruction Manual Main Menu: After startup, the Eliminator Competition will enter the Main Menu. Press the right/left arrow buttons to move through the menu.

More information

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11 ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11 The Portatree Eliminator Super 2000 Competition Track Timer can be used with an IBM Compatible Personal Computer connected through Com Port

More information

STAND alone & p.c. VERSION

STAND alone & p.c. VERSION STAND alone & p.c. VERSION ECONOMY TRACK SYSTEMS 1/4 & 1/8 Mile Asphalt Track Dirt / Sand Track Mud Track Snowmobile Track R/C Car Track Custom Track Systems Timing to.001 Accuracy Time Slip Printer Optional

More information

INSTALLATION PROCEDURE 1/4 & 1/8 MILE PERMANENT TRACK

INSTALLATION PROCEDURE 1/4 & 1/8 MILE PERMANENT TRACK INSTALLATION PROCEDURE 1/4 & 1/8 MILE PERMANENT TRACK 1) Unpack all of the equipment and immediately inspect for shipping damage. Damages should be immediately reported to the carrier and noted on the

More information

ELIMINATOR INSTRUCTIONS Table of Contents

ELIMINATOR INSTRUCTIONS Table of Contents ELIMINATOR INSTRUCTIONS Table of Contents 1. PRACTICE MODE A. Toggling from Full to Pro Tree B. Toggling from 1 to 2 Users C. Toggling from Auto to Manual Reset D. Setting the Delay Boxes E. Setting a

More information

Tournament Manager: Running a VEX IQ Event - Beginner

Tournament Manager: Running a VEX IQ Event - Beginner Tournament Manager: Running a VEX IQ Event - Beginner Indiana IQ Event Partner Workshop Agenda 1. Main Window a. Once i. The Main Window has a standard menu bar. ii. A series of tabbed pages filling the

More information

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS WARNING THE WARRANTIES MADE BY MSA WITH RESPECT TO THE PRODUCT ARE VOIDED IF THE PRODUCT IS NOT USED AND MAINTAINED IN ACCORDANCE

More information

WELCOME TO THE REVOLUTION

WELCOME TO THE REVOLUTION USER GUIDE WELCOME TO THE REVOLUTION THANK YOU FOR CHOOSING THE GCQUAD We listened to what you wanted - and created the most accurate, versatile and game-enhancing ball and club analysis solution available

More information

HyperSecureLink V6.0x User Guide

HyperSecureLink V6.0x User Guide HyperSecureLink V6.0x User Guide Note: This software works with the LS-30 Version (06.0x or later) 1, Hardware Installation: 1-1, Connection Diagram for USB or RS-232 Computer Interface To LS-30 CM1 To

More information

For running only the scoresheet application without any video features only some very basic hardware / software requirements have to be fulfilled:

For running only the scoresheet application without any video features only some very basic hardware / software requirements have to be fulfilled: Digital Scoresheet user manual Requirements For running only the scoresheet application without any video features only some very basic hardware / software requirements have to be fulfilled: Laptop, preferably

More information

1. Hardware Hardware Connection... 2 Connection Diagram... 3 DIP Switch Settings & 10 PIN Button Layout... 4

1. Hardware Hardware Connection... 2 Connection Diagram... 3 DIP Switch Settings & 10 PIN Button Layout... 4 Table of Contents 1. Hardware... 2 Hardware Connection... 2 Connection Diagram... 3 DIP Switch Settings... 4 36 & 10 PIN Button Layout... 4 2. Bookkeeping & Adjustment... 5 Access Flow Chart... 5 System

More information

SPLIT HOPKINSON PRESSURE BAR OPERATIONS MANUAL 5/9/2014

SPLIT HOPKINSON PRESSURE BAR OPERATIONS MANUAL 5/9/2014 B Calibration of Split Hopkinson Pressure Bar Setup: Calibration is performed by comparing the wave speed of the initial pulse versus the reflected pulse and calculating the Energy Ratio. This ratio gives

More information

Microsoft Windows Software Manual for FITstep Stream Version 4

Microsoft Windows Software Manual for FITstep Stream Version 4 Thank you for purchasing this product from Gopher. If you are not satisfied with any Gopher purchase for any reason at any time, contact us and we will replace the product, credit your account, or refund

More information

TdC 8000 Page 1. Version: E Page 1

TdC 8000 Page 1. Version: E Page 1 TdC 8000 Page 1 Version: E-97-03-27 Page 1 TdC 8000 Page 2 Operation elements and connectors 1 Switch for start number input with three positions: up: increment up automatically as each racer starts middle:

More information

BASnet LightiView Install Guide

BASnet LightiView Install Guide BASnet LightiView 1025 Cobb Place Blvd Suite 100 Kennesaw, GA 30144 800-241-9173 www.triateklighting.com ATTENTION This section serves as a notice of the immediate or potential dangers involved when working

More information

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408) RACEAMERICA T i m i n g S y s t e m s Demo Tree Controller Owner s Manual Models 3204D, 3204DW & 3204DX Rev D RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA 95055-3469 (408) 988-6188 http://www.raceamerica.com

More information

Digi Connect ME 9210 Linux: 2 nd serial over FIM

Digi Connect ME 9210 Linux: 2 nd serial over FIM Digi Connect ME 9210 Linux: 2 nd serial over FIM Document History Date Version Change Description 09/04/2009 Initial entry/outline Table of Contents Document History... 2 Table of Contents... 2 1 Problem

More information

Lockstep. Reference Manual. Last updated on September 23, Figure 53, LLC

Lockstep. Reference Manual. Last updated on September 23, Figure 53, LLC Lockstep Reference Manual Last updated on September 23, 2016 Figure 53, LLC 2018 Table of Contents Table of Contents Support Lockstep Documentation 1 2 3 Support Lockstep Support 3 Lockstep Documentation

More information

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual Air Bubbler Depth Gauge DG2200 Installation and Reference Manual Rev. 3.2.2 06/2011 Installation and Reference Manual Page 2 Contents Chapter 1: Installation and Overview... 3 1.1 DG2200 Location Diagram...

More information

Quick Start Guide. A. Hardware installation B. Software installation C. Start the software for the first time D. Do your first measurement

Quick Start Guide. A. Hardware installation B. Software installation C. Start the software for the first time D. Do your first measurement Quick Start Guide This Quick Start Guide describes the hardware and software installation process and the Measurement feature in a simple way. Please follow the sequence of the steps to avoid problems

More information

1/4 & 1/8 Mile Asphalt Track Dirt / Sand Track Mud Track Snowmobile Track R/C Car Track Custom Track Systems Windows Software

1/4 & 1/8 Mile Asphalt Track Dirt / Sand Track Mud Track Snowmobile Track R/C Car Track Custom Track Systems Windows Software 1/4 & 1/8 Mile Asphalt Track Dirt / Sand Track Mud Track Snowmobile Track R/C Car Track Custom Track Systems Windows Software Ttm NHRA Style LED Bulbs Time Slip Printer Order# 1-800-541-7613 Ext: 503 Tech#

More information

XC2 Client/Server Installation & Configuration

XC2 Client/Server Installation & Configuration XC2 Client/Server Installation & Configuration File downloads Server Installation Backup Configuration Services Client Installation Backup Recovery Troubleshooting Aug 12 2014 XC2 Software, LLC Page 1

More information

Helium Level Measurement Unit

Helium Level Measurement Unit Helium Level Measurement Unit HLMU User Manual Version 002 The information in this manual may be altered without notice. BRUKER BIOSPIN accepts no responsibility for actions taken as a result of use of

More information

RM-80 respiration monitor

RM-80 respiration monitor RM-80 respiration monitor User Manual September 18, 2015 0025-003M 950 North Hague Avenue Columbus, Ohio 43204-2121 USA Sales: sales@colinst.com Service: service@colinst.com Phone: (614) 276-0861 Fax:

More information

Setting Up the Ingenico isc250 Pinpad via USB

Setting Up the Ingenico isc250 Pinpad via USB One Blue Hill Plaza, 16 th Floor, PO Box 1546 Pearl River, NY 10965 1-800-PC-AMERICA, 1-800-722-6374 (Voice) 845-920-0800 (Fax) 845-920-0880 Setting Up the Ingenico isc250 Pinpad via USB The following

More information

Digi Connect ME 9210 Linux: serial port 2 for JTAG modules

Digi Connect ME 9210 Linux: serial port 2 for JTAG modules Digi Connect ME 9210 Linux: serial port 2 for JTAG modules Document History Date Version Change Description 08/05/2009 Initial entry/outline Table of Contents Document History... 2 Table of Contents...

More information

Microfluidic Demonstration

Microfluidic Demonstration Microfluidic Demonstration Co-flow of liquids across a microfluidic chip Create a microfluidic controller to flow liquids across a microfluidic chip. 1. Assemble fluidic circuits and attach to breadboard.

More information

OMNISPORT 2000 SWIMMING QUICK REFERENCE

OMNISPORT 2000 SWIMMING QUICK REFERENCE Before During After OMNISPORT 2000 SWIMMING QUICK REFERENCE 1. Confirm that the timer is reset. 2. Set the timer to the correct event and heat. The right LCD, line 2 displays E:(event) H:(heat) R:(round)

More information

Operating instructions Electrical switching facility pco

Operating instructions Electrical switching facility pco Operating instructions Electrical switching facility pco from software version V1.33 on TABLE OF CONTENTS 1. Before you start... 4 1.1 Brief description... 4 1.2 Using this manual... 4 2. pco integrated

More information

SDM-2012 Docking Station Standalone Configuration Operator s Manual

SDM-2012 Docking Station Standalone Configuration Operator s Manual SDM-2012 Docking Station Standalone Configuration Operator s Manual Part Number: 71-0254RK Revision: P5 Released: 10/5/12 www.rkiinstruments.com Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

Perfect Golf Quick Start Guide

Perfect Golf Quick Start Guide Quick Start Guide Perfect Golf Quick Start Guide To play Perfect Golf you must first have purchased the following: 1. A SkyTrak Launch Monitor 2. Have an active Play and Improve Package 3. Have purchased

More information

DDR Dive Data Recorder Manual - Rel /12

DDR Dive Data Recorder Manual - Rel /12 DDR Dive Data Recorder Manual - Rel. 1.1 2/12 TABLE OF CONTENTS 1. WHAT IS THE DDR? 4 2. TECHNICAL CHARACTERISTICS 5 3. DOWNLOADING DATA TO A PC 6 4. DDR MANAGER 7 5. CONFIGURE DEVICE BUTTON 9 6. READ

More information

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel DTLS Manual This document contains proprietary information. Copyright 2015 Scientific Data Systems, Inc. All rights reserved. 1 Depth Tension

More information

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120 MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120 QUICK START GUIDE P/N 6006154, REVISION C MAY 2013 Model 8120 Mask Integrity Tester is patented under U.S. Patent No. 8,312,761. Additional patents are pending.

More information

DIVE MEET SCORING INSTRUCTIONS. Day before meet

DIVE MEET SCORING INSTRUCTIONS. Day before meet DIVE MEET SCORING INSTRUCTIONS Day before meet Physical set up Set up registration/scoring table #1 on 1 meter side and scoring table #2 on 3 meter side of diving well, judges chairs, and award stand as

More information

The Race Director. IPICO Integration Direct Connect [IPICO INTEGRATION]

The Race Director. IPICO Integration Direct Connect [IPICO INTEGRATION] 2017 The Race Director IPICO Integration Direct Connect [IPICO INTEGRATION] This document explains how to manage the results data between your IPCIO readers and Race Director using a direct connection

More information

1. SYSTEM SETUP AND START TOURNAMENT... 8

1. SYSTEM SETUP AND START TOURNAMENT... 8 PICTORIAL HANDBALL MATCH STATISTICS (PHMS for Windows 7 Version E5.1) User's Manual November 2011 1. SYSTEM... 6 1.1 INTRODUCTION... 6 1.2 SYSTEM NAME... 6 1.3 SYSTEM FUNCTION... 7 2. SETUP AND START...

More information

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION 1 INFORMATION and TECNICAL DESCRIPTION 14 2 AIRLEADER Professional Compressor Management + Compressed Air Visualisation + Alarm Service Management + AIRLEADER - has been the effective answer for compressed

More information

TdC 8001 Page 2. Version:E Page 2

TdC 8001 Page 2. Version:E Page 2 TdC 8001 English TdC 8001 Page 2 Version:E-2008-01-23 Page 2 TdC 8001 Page 3 Operation elements and connectors 1 Start-Display 2 External supply LED status light 3 Meter for monitoring power supply, alignment

More information

1. Hardware...2. Hardware Connection... Connection Diagram... DIP Switch Setting... & 0 PIN Button Layout...

1. Hardware...2. Hardware Connection... Connection Diagram... DIP Switch Setting... & 0 PIN Button Layout... Table of Contents 1. Hardware...2 Hardware Connection... Connection Diagram... DIP Switch Setting... & 0 PIN Button Layout... 3. Bookkeeping & Adjustment...5 Access Flow Chart... System Settings... Chance

More information

Annual Inspection and Calibration Checklist VAF Oilcon MK-6(M) MEPC.108(49) Page 1 of 5

Annual Inspection and Calibration Checklist VAF Oilcon MK-6(M) MEPC.108(49) Page 1 of 5 Page 1 of 5 Vessel Name: Serial number MCU: Serial Number EPU: Serial Number Skid: Mains Supply: V AC @ Hz Software version MCU: Software version EPU: K-factor Cell: K-factor Skid Flowmeter: P/L Maximum

More information

TESLAGON. ShotHelper Manual. How to install and use the Program. Version /30/2014

TESLAGON. ShotHelper Manual. How to install and use the Program. Version /30/2014 TESLAGON ShotHelper Manual How to install and use the Program 11/30/2014 Version 1.11 Table of Contents Introduction... 3 Installation Process... 3 ShotHelper Quick Setup... 4 The Main Window... 6 The

More information

Overview. Front Panel: Keypad and Display

Overview. Front Panel: Keypad and Display Overview The GA-200B is an analyzer that integrates a gas sampling system with sensors to measure and display the concentrations of oxygen and carbon dioxide in a sample as the percentage of a gas in the

More information

Product Overview. Product Description CHAPTER

Product Overview. Product Description CHAPTER CHAPTER 1 This chapter provides a functional overview of the Cisco Redundant Power System 2300 and covers these topics: Product Description, page 1-1 Features, page 1-3 Supported Devices, page 1-4 Deployment

More information

TR Electronic Pressure Regulator. User s Manual

TR Electronic Pressure Regulator. User s Manual TR Electronic Pressure Regulator Page 2 of 13 Table of Contents Warnings, Cautions & Notices... 3 Factory Default Setting... 4 Quick Start Procedure... 5 Configuration Tab... 8 Setup Tab... 9 Internal

More information

Impulse G3. Race System. User Guide V0412

Impulse G3. Race System. User Guide V0412 Impulse G3 Race System User Guide 60017 V0412 Materials Included Start gate Finish gate 4 gate supports 8 steel pull pins 8 gate support screws Spool of monofilament line 2 launch pods 2 launch triggers

More information

CONSUMER MODEL INSTALLATION GUIDE

CONSUMER MODEL INSTALLATION GUIDE CONSUMER MODEL INSTALLATION GUIDE System requirements Windows System Requirements To use your TOMI and its software, your system should have: A Microsoft Windows compatible PC with a Pentium IV processor

More information

Diver-Office. Getting Started Guide. 2007, Schlumberger Water Services

Diver-Office. Getting Started Guide. 2007, Schlumberger Water Services Diver-Office Getting Started Guide 2007, Schlumberger Water Services Copyright Information 2007 Schlumberger Water Services. All rights reserved. No portion of the contents of this publication may be reproduced

More information

Instruction Manual. BZ7002 Calibration Software BE

Instruction Manual. BZ7002 Calibration Software BE Instruction Manual BZ7002 Calibration Software BE6034-12 Index _ Index Index... 2 Chapter 1 BZ7002 Calibration Software... 4 1. Introduction... 5 Chapter 2 Installation of the BZ7002... 6 2. Installation

More information

Steltronic StelPad User Guide

Steltronic StelPad User Guide StelPad User Guide Steltronic StelPad User Guide Contents Contents... 1 About StelPad and its Features... 3 StelPad System Elements... 3 StelPad Computer Integration with Focus... 4 Enable Custom Graphic

More information

TdC 8000 plus. English

TdC 8000 plus. English TdC 8000 plus English TdC 8000 Page 2 1 2 3 4 5 6 7 8 start number group hour min. sec. 1/100 start number group lap ext. supply man. F1 F2 F3 F4 c0 c1 c2 c3 c4 c5 c6 c7 c8 c9 STARTCLEARBLOCK YES F1 STOP

More information

Setting up the Ingenico isc250 Pinpad via USB in Windows 8

Setting up the Ingenico isc250 Pinpad via USB in Windows 8 One Blue Hill Plaza, 16 th Floor, PO Box 1546 Pearl River, NY 10965 1-800-PC-AMERICA, 1-800-722-6374 (Voice) 845-920-0800 (Fax) 845-920-0880 Setting up the Ingenico isc250 Pinpad via USB in Windows 8 The

More information

Tru Flight TRUFLIGHT INSTALLATION GUIDE TRUGOLF.COM

Tru Flight TRUFLIGHT INSTALLATION GUIDE TRUGOLF.COM Tru Flight T R A C K I N G S Y S T E M TRUFLIGHT INSTALLATION GUIDE TRUGOLF.COM TruFlight Camera Tracking System Setup & Installation TruFlight : How It Works... 1 TruFlight Components... 1 TruFlight Installation...

More information

Presents the following instructional slide show:

Presents the following instructional slide show: Presents the following instructional slide show: Operating Procedures for the Sure Shot Acoustic Fluid Level System. Sure Shot Acoustic Fluid Level System Well head attachment and accessories Complete

More information

1. Hardware Bookkeeping & Adjustment...7. Access Flow Chart... 7 System Adjustment... 8 Chance Adjustment... 9 Touch Screen Calibration...

1. Hardware Bookkeeping & Adjustment...7. Access Flow Chart... 7 System Adjustment... 8 Chance Adjustment... 9 Touch Screen Calibration... Table of Contents 1. Hardware...2 Connectors Descriptions... 2 Connecting 2nd Screen and Touch Panel (Optional)... 3 Connection Diagram... 4 DIP Switch Settings... 5 36 & 10 PIN Button Layout... 5 Solving

More information

Wickets Administrator

Wickets Administrator Wickets Administrator Software For Managing Stored Value Wickets 01/08/2008 Product Details And Operating Instructions Overview This page describes each major function of Wickets Administrator in detail.

More information

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output CONSOLE-320 Item 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output Table of contents 1. INTRODUCTION...2 1.1 Power supply...2 1.2 Connections...2 1.3

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

AIR FLOW ANEMOMETER INSTRUCTION MANUAL

AIR FLOW ANEMOMETER INSTRUCTION MANUAL AIR FLOW ANEMOMETER INSTRUCTION MANUAL Thank you for purchasing our company Air Flow Anemometer. This manual provides relative information on how to use the Air Anemometer and warning in operation Please

More information

Design Envelope Booster. Sequence of operation

Design Envelope Booster. Sequence of operation Design Envelope Booster Sequence of operation File No: 62.835 Date: february 11, 2015 Supersedes: 62.835 Date: july 11, 2014 sequence of operation Design Envelope Booster 2 general The packaged domestic

More information

APA software instruction manual

APA software instruction manual 1. Starting the program In order to start the control software for the APA device press APAxx shortcut located on the desktop of the supplied computer. XX corresponds to the current software version. When

More information

SENSUS PRO MANAGER (for SENSUS or SENSUS PRO devices) User s Guide -- Windows. Version 2.0 Published October 17, ReefNet Inc.

SENSUS PRO MANAGER (for SENSUS or SENSUS PRO devices) User s Guide -- Windows. Version 2.0 Published October 17, ReefNet Inc. SENSUS PRO MANAGER (for SENSUS or SENSUS PRO devices) User s Guide -- Windows Version 2.0 Published October 17, 2002 2002 ReefNet Inc. 1.0 Introduction The SENSUS PRO data recorder captures the time, depth,

More information

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA Software version 2.6 Table of contents 1 Introduction...3 1.1 Optical Sensor Technology...3 1.2 Installation...4 1.3 Operation...5

More information

SWIM MEET MANAGER 5.0 NEW FEATURES

SWIM MEET MANAGER 5.0 NEW FEATURES SWIM MEET MANAGER 5.0 NEW FEATURES Updated January 24, 2014 1 ABOUT SWIMMING MEET MANAGER 5.0 MEET MANAGER 5.0 for ming (SWMM) is HY-TEK's 6th generation of Meet Management software. Provides the very

More information

RUNNING A MEET WITH HY-TEK MEET MANAGER

RUNNING A MEET WITH HY-TEK MEET MANAGER SETTING UP THE MEET 1. A database setup for the current season can be found on the CCAA website www.ccaaswim.org this will have the events and other information for the meet setup already in place. 2.

More information

ROTAX GLOBAL APP GUIDE. (revised ) GRAND FINALS EDITION

ROTAX GLOBAL APP GUIDE. (revised ) GRAND FINALS EDITION ROTAX GLOBAL APP GUIDE (revised 16.09.2018) GRAND FINALS EDITION Table of Contents Chap. Content Page Table of Contents 2 Basic Information 3 1. Download Rotax Global App 5 2. Get Internet Connectivity

More information

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER Features ±0.01% FS Measurement & Control Accuracy ±0.001% /ºC Thermal Stability Pressure Ranges from ±1 psid to 1200 psia Applications Barometric Measurement

More information

This addendum describes the back pressure control implementation if FuelCell Version 4.1a and later.

This addendum describes the back pressure control implementation if FuelCell Version 4.1a and later. FuelCell Addendum - Back Pressure Controls D. Johnson, Scribner Associates, Inc. 7/23/2015, Ver. 6 Introduction This addendum describes the back pressure control implementation if FuelCell Version 4.1a

More information

MANUAL TIMING. PRACTICAL GUIDE

MANUAL TIMING. PRACTICAL GUIDE MANUAL TIMING. PRACTICAL GUIDE TABLE OF CONTENTS 1. Introduction... 2 2. Small Events... 2 2.1. Capturing Times... 3 2.2. Saving Results... 4 3. Mid-Sized Events... 5 3.1. Capturing Times... 6 3.2. Recording

More information

Center Command Version 3. Operations Manual

Center Command Version 3. Operations Manual Center Command Version 3 Operations Manual Version: July 26, 2010 Table of Contents OVERVIEW... 2 OVERVIEW OF COMPUTER SCORE CENTER COMMAND... 2 MAIN MENU FUNCTIONS (IF MODULES INSTALLED)... 3 CENTER

More information

eflo ELECTRONIC GAS FLOW METER OPERATIONS MANUAL

eflo ELECTRONIC GAS FLOW METER OPERATIONS MANUAL eflo ELECTRONIC GAS FLOW METER OPERATIONS MANUAL Super Systems Inc. 7205 Edington Drive Cincinnati, OH 45249 513-772-0060 Fax: 513-772-9466 www.supersystems.com Super Systems Inc. USA Office Corporate

More information

Version-E E100930

Version-E E100930 Version-E080529 E100930 Football Manual Important Information General Before using your ALGE-TIMING device read the complete manual carefully. It is part of the device and contains important information

More information

Mac Software Manual for FITstep Pro Version 2

Mac Software Manual for FITstep Pro Version 2 Thank you for purchasing this product from Gopher. If you are not satisfied with any Gopher purchase for any reason at any time, contact us and we will replace the product, credit your account, or refund

More information

FRDS GEN II SIMULATOR WORKBOOK

FRDS GEN II SIMULATOR WORKBOOK FRDS GEN II SIMULATOR WORKBOOK Trotter Control Inc 2015 Document# Revision Revised 9001-0038 FRDS GEN II Simulator Workbook E 02/15/2015 by DC FRDS GEN II Simulator Workbook This workbook is a follow-on

More information

ALGE DIVE! ALGE. ALGE-TIMING GmbH & Co

ALGE DIVE! ALGE. ALGE-TIMING GmbH & Co ALGE ALGE DIVE! ALGE-TIMING GmbH & Co Rotkreuzstrasse 39 A-6890 Lustenau Telephone: +43 5577-85969 Fax: +43 5577-85969 e-mail: office@alge-timing.com Internet: www.alge-timing.com Table of contents 1.

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

Stand-Alone Bubble Detection System

Stand-Alone Bubble Detection System Instruction Sheet P/N Stand-Alone Bubble Detection System 1. Introduction The Bubble Detection system is designed to detect air-bubble induced gaps in a bead of material as it is being dispensed. When

More information

AX5000 Operational Manual

AX5000 Operational Manual MIYACHI AMERICA CORPORATION The World Leader in Hermetic Sealing Systems AX5000 Operational Manual 0 Document #107-00092-001 Dec, 2013 AX5000 Operational Manual Miyachi America Corporation 1820 S. Myrtle

More information

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc. The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is

More information

Track and Field Interface

Track and Field Interface Track and Field Interface Quick Guide ED-14511 Rev 4 5 June 2007 ED-14511 P-1173 Rev 4 5 June 2007 Please fill in the information below for your display; use it for reference when calling Daktronics for

More information

LEGO Engineering Conferences ROBOLAB and MINDSTORMS Education Version 4.5 March 2008

LEGO Engineering Conferences ROBOLAB and MINDSTORMS Education Version 4.5 March 2008 LEGO Engineering Conferences ROBOLAB and MINDSTORMS Education Version 4.5 March 2008 NXT-G Program Book II: Intermediate Robotics Activities for use with the NXT 2008 Tufts Center for Engineering Education

More information

Oxygen Meter User Manual

Oxygen Meter User Manual Oxygen Meter User Manual Monday, July 23, 2007 1. Outline...2 2. Program...3 2.1. Environment for program execution...3 2.2. Installation...3 2.3. Un installation...3 2.4. USB driver installation...3 2.5.

More information

Dive Planet. Manual. Rev Basic User Interface. 2 How to organize your dives. 3 Statistics. 4 Location Service and Map View.

Dive Planet. Manual. Rev Basic User Interface. 2 How to organize your dives. 3 Statistics. 4 Location Service and Map View. Dive Planet Manual Rev 1.2 1 Basic User Interface 2 How to organize your dives 3 Statistics 4 Location Service and Map View 5 Settings 6 Languages 7 Buddies and guide 8 Backup and restore of the data 9

More information

PRODUCT MANUAL. Diver-Mobile for Android

PRODUCT MANUAL. Diver-Mobile for Android PRODUCT MANUAL Diver-Mobile for Android Contact details: Van Essen Instruments B.V. Van Essen Instruments - Canada Delftechpark 20 630 Riverbend Drive, Suite 100 2628 XH Delft Kitchener, ON, The Netherlands

More information

HumiSys HF High Flow RH Generator

HumiSys HF High Flow RH Generator HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously

More information

Boyle s Law: Pressure-Volume Relationship in Gases

Boyle s Law: Pressure-Volume Relationship in Gases Boyle s Law: Pressure-Volume Relationship in Gases The primary objective of this experiment is to determine the relationship between the pressure and volume of a confined gas. The gas we will use is air,

More information

AUTO PUMP STATUS CENTER

AUTO PUMP STATUS CENTER INSTRUCTION MANUAL AUTO PUMP STATUS CENTER PRESSURE ONLY MODEL #: 091-198-12-AP File: IM_091-198-12-AP_revD.indd Rev: D, pg 3 WD Revised By: PSS Date: 2-01-2016 3 YEAR WARRANTY INTRODUCTION The Auto Pump

More information

Drag Racing Scoreboards

Drag Racing Scoreboards Drag Racing Scoreboards Interfaced to Portatree Silver & Gold Owner Manual s Models 6629, 6429, 6611 & 6411 Rev H RaceAmerica Corporation 105 Bonaventura Drive San Jose, CA 95134 (408) 988-6188 www.raceamerica.com

More information

MULTITUBE BUBBLE TUBE BY ROMPA (U)

MULTITUBE BUBBLE TUBE BY ROMPA (U) Page 1 of 16 MULTITUBE BUBBLE TUBE BY ROMPA 19781 (U) CONTENTS 1 x Base Unit (chassis) 1 x Base Cover (white plastic cover) 1 x Multitube Bubble Tube Column 1 x Bubble Tube Cap 1 x Power Supply (black

More information

Optical Time Domain Reflectometer. Operating System 2 Windows XPe Windows XP Pro with desktop option 256 MB

Optical Time Domain Reflectometer. Operating System 2 Windows XPe Windows XP Pro with desktop option 256 MB CMA 4500 Series Optical Time Domain Reflectometer The CMA 4500 continues NetTest s tradition as the industry s premier OTDR solution designed with the high performance and scalability necessary to meet

More information

Soft Systems. Log Flume - 1. Enter Specification. Activity One ACTIVITIES. Help. for Logicator

Soft Systems. Log Flume - 1. Enter Specification. Activity One ACTIVITIES. Help. for Logicator Log Flume - 1 ACTIVITIES These sheets present a series of activities for building your own programs to control the Log Flume Soft System. Together, they build into a complete control system for the log

More information

IBU3 Manual Addendum 1

IBU3 Manual Addendum 1 This addendum covers the follow items. Connection of airsoft micro switch Connection of Taigen airsoft recoil units Selecting airsoft mode Settings for clutch style gearboxes Motor enable selection Confirmation

More information

Software Manual for FITstep Pro Version 2

Software Manual for FITstep Pro Version 2 Thank you for purchasing this product from Gopher. If you are not satisfied with any Gopher purchase for any reason at any time, contact us and we will replace the product, credit your account, or refund

More information

Software for electronic scorekeeping of volleyball matches, developed and distributed by:

Software for electronic scorekeeping of volleyball matches, developed and distributed by: Software for electronic scorekeeping of volleyball matches, developed and distributed by: Developed for the rules of USports 2017-18 As adopted by Ontario University Athletics for Men s & Women s Volleyball

More information

[MYLAPS INTEGRATION]

[MYLAPS INTEGRATION] 2018 The Race Director MyLaps Integration Manual [MYLAPS INTEGRATION] This document explains how to manage the results data between your MyLaps readers and Race Director using manual file transfers. Contents

More information

Panther 5 Acute Care Ventilator

Panther 5 Acute Care Ventilator 1 HIGHLIGHTS High performance and advanced features target the ICU environment Utilizes an internal blower with a specially designed flow control valve removing the need for using compressed air without

More information

Gas Analyzer for TC Sensors (CO2, H2, N2) Series 62101, 64101, Operating Manual

Gas Analyzer for TC Sensors (CO2, H2, N2) Series 62101, 64101, Operating Manual Gas Analyzer for TC Sensors (CO2, H2, N2) Series 62101, 64101, 65101 Operating Manual Disclaimer Please read and understand the user manual before installing and using the products described herein. It

More information

1. Hardware Bookkeeping & Adjustment Access Flow Chart... 6 System Adjustment... 7 Chance Adjustment... 8 Touch Screen Calibration...

1. Hardware Bookkeeping & Adjustment Access Flow Chart... 6 System Adjustment... 7 Chance Adjustment... 8 Touch Screen Calibration... Table of Contents 1. Hardware... 2 Connectors Descriptions... 2 Connection Diagram... 3 DIP Switch Settings... 4 36 & 10 PIN Button Layout... 4 Solving Hopper SSR Error... 5 2. Bookkeeping & Adjustment...

More information

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments Pegas 4000 MF Gas Mixer InstructionManual Contents I Table of Contents Foreword Part I Introduction 1 2 1 System overview... 2 2 Specifications... 3 Part II Installation 4 1 Rear panel connections...

More information

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73 USER MANUAL Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * *) Require software ID: DID-SW-001 1/73 Table of contents 1 General... 3 1.1

More information