Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions)

Size: px
Start display at page:

Download "Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions)"

Transcription

1 Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions) 1. Uncrate blender from packaging. 2. Lift the blender and position over machine throat or floor stand; set in position and secure by tightening bolts. 3. Mount the material conveying system receivers on top of the blender supply hoppers. 4. Align the weigh hopper on the load cell brackets. 5. Check the slide gate metering assemblies to ensure they freely slide back and forth. 6. Provide a correctly sized and protected power supply to the unit. The standard Slide Gate/Auger blending system is designed to operate on /1/60 or /1/50 supply voltage. A single 15A service is sufficient for most blenders (verify this with the blender s name plate information. If local electrical codes require fusing or disconnects, these items must be supplied, wired, and mounted by the customer. Each blending system MUST be connected to a separate source of power. 7. Attach the operator touch screen to the MAIN DISPLAY port on the blender. Always disconnect the power supply before servicing the unit. 8. The Slide Gate/Auger blending system requires approximately 1 CFM (1.7 m³/hr) at 60 PSI (4.14 bar) maximum air pressure to operate properly. (See figure below). The air supply should be filtered through a 5 micron air filter with a water separator. 9. The blender should use a dedicated line to ensure proper air supply. To prevent damage to the equipment, do not exceed 60 PSI (4.14 bar) air pressure. Always disconnect the air supply when conducting any kind of maintenance. Unit Operation (Please refer to operation manual for complete instructions.) 1. Check to make sure all ingredient supply hoppers to be used are filled with material. 2. Turn ON the blender using the ON/OFF selector switch on the control panel. 3. Wait for Main Recipe Screen to appear on the touch screen; it may take up to one minute. (See figure below). 4. Enter the recipe using the operator touch screen. Press Accept New Recipe when finished. 5. Press the Push to Start or Stop the Blender to begin the blending process.

2 Main Recipe Screen Display Recipe Entry Mode New Recipe Input Actual Weight Indicator for Timed Batch Mixer Status Start/Stop Blender Immediately Stop Blender Accept New Recipe Target Weight Go To Recipe Book Feeder Type Indicator Go To Inventory Screen Quick Controller Setup (Change controller to EZ mode for injection or PERCENTAGE mode for extrusion.) 1. From the Recipe Page, touch the ACS icon, enter 5413, and press the key. 2. Press Recipe Format. Toggle through the EZ, Percentage, or Parts modes (see figure below). 3. Press the Done key two times until you return to the Recipe Page. 4. Enter your new recipe as described above, if necessary. Touch Here to Change

3 Checking the Calibration (Please refer to operation manual for complete calibration instructions.) NOTE: It is not necessary to calibrate the weight scale on a brand new blender; although, it is recommended that the calibration be checked periodically to ensure that the reported inventory totals are accurate. A bad calibration is worse than no calibration in most cases. 1. From the Recipe Page, touch the AEC icon and enter 5413 ; then press the key. 2. Touch Calibration and then Direct Scale Readout. (See figure below.) 3. Remove the weigh hopper if possible to do without tools (Don t do this for OA blenders). 4. Locate the weight display for each load cell,or one load cell for OA blender with an HC style mixer. Record values. 5. Add the calibration weight to each load cell mounting bracket and record the value displayed in weight, as in step Subtract the values recorded in steps 4 and 5. This is the measured weight. If the measured weight is within lbs. of the weight stamped on the calibration weight, then it is within specification. If not, then follow the steps below to calibrate the blender. 7. Store the calibration weights in a safe location DO NOT DISCARD! Direct Scale Readout Display Current Loadcell Weight Current Loadcell Weight Calibrating if necessary 1. From the Recipe Page, touch the AEC icon and enter 5413, then press the key. 2. Touch Calibration and then Scale Calibration (see figure below). 3. Follow the onscreen instructions to complete the calibration. 4. The blender will evaluate the calibration and indicate if it is properly calibrated. 5. Press the Done key three times, and you will return to the main menu. Calibration Menu Screen Enter in the Calibration Weight Current Loadcell Bits Follow Instructions Press here to perform the calibration Go Back to the Calibration Directory

4 Menu Structure for Allen-Bradley Control System Recipe Page Start Change Recipe Values by touching the number you wish to change Touch Accept New Recipe button after you ve made the desired changes Touch Undo button to cancel a recipe change before accepting it Start or stop the blender by touching the Push to Start or Stop button Access Recipe Book Page Access Clean Out Page Access Inventory Page Access Setup Page Recipe Book Page Save the running recipe to the book. Delete a stored recipe Load a stored recipe Erase all stored recipes Modify the product ID for a stored recipe Return to the Recipe Page Clean Out Page Empty the blender hoppers Manually operate mixer, weigh hopper dump gate,, and slide gate below mixer View/test all inputs/outputs on the blender Return to Recipe Page Inventory Page View/print accumulated inventories View batch time View maximum capacity View average process rate Return to Recipe Page Setup Page Touch the AEC icon and enter in user password Recipe Format Percentage, Parts, or EZ mode Metering order Batch size Inventory shutdown Batch ready mode Auto start mode Weigh every batch options Change recipe without stopping Report Setup Blender number Auto print option Auto clear option Auto interval option Auto start time Calibration Scale Calibration Direct Scale Readout Feeder Calibration Mixer & Dump Setup Mixing time Remix time Dump time Dump delay Dump cycles Mixer dump time Time/continuous mixing option Panel View Config View software version Access Panel View Config setup to modify printer/time settings and to load new software User Password Change default user password Units Blender data units (lbs/kg) Target v. actual data units (lbs/kg) Alarm Log View, print, or clear alarm log Alarm Setup Stop/Continue when out of material Alarm/No Alarm when out of material Alarm Silence delay Accept recipe alarm enable/disable Network Setup IP Address Subnet Mask Send Config to ENI Module Enable Ethernet Configurator Modbus Plus Disabled Recommended Spare Parts (Please refer to operation manual for complete list) User Interface Lock Lock the user interface to prevent others from making changes or viewing the blender Part Description 150 Model 500 Model 900 Model 2500 Model 4000 Model 6000 Model Mixer gear motor # Mixer agitator # Mixer coupling N/A Weigh hopper asbly. # A A A A A Valve stock asbly. N/A A (4-component) or A (6-component) A/B Panel View operator touch screen (no enclosure) A/B PLC MicroLogix CPU A/B PLC Base A

5

6

7

8

Inventory Monitor Units Red-Lion Display. Models: OI, SIT, CIT

Inventory Monitor Units Red-Lion Display. Models: OI, SIT, CIT Inventory Monitor Units Red-Lion Display Models: OI, SIT, CIT Part Number: 882.02323.00 Bulletin Number: BLN1-620 Effective: February 1, 2013 an company Write Down Your Serial and Software Revision Numbers

More information

Touch Screen Guide. OG-1500 and OG Part # T011

Touch Screen Guide. OG-1500 and OG Part # T011 Touch Screen Guide OG-1500 and OG-2000 Part # 9000000.T011 Effective 11/2010 External View Internal View 1. Transducer Banks 2. Oxygen Sensor 3. PLC These are the two manifolds with three (3) transducers

More information

Stand-Alone Bubble Detection System

Stand-Alone Bubble Detection System Instruction Sheet P/N Stand-Alone Bubble Detection System 1. Introduction The Bubble Detection system is designed to detect air-bubble induced gaps in a bead of material as it is being dispensed. When

More information

MP15 Jockey Pump Controller

MP15 Jockey Pump Controller Setup and Operating Instructions MP15 Jockey Pump Controller This manual provides general information, installation, operation, maintenance, and system setup information for Metron Model MP15 Jockey Pump

More information

Model 130M Pneumatic Controller

Model 130M Pneumatic Controller Instruction MI 017-450 May 1978 Model 130M Pneumatic Controller Installation and Operation Manual Control Unit Controller Model 130M Controller is a pneumatic, shelf-mounted instrument with a separate

More information

E L E V E N C R O Z E R V I L L E R D. A S T O N, P A WEIGH SCALE BLENDER with "FOUR" COMPONENT SOFTWARE SEPTEMBER 26, 2013

E L E V E N C R O Z E R V I L L E R D. A S T O N, P A WEIGH SCALE BLENDER with FOUR COMPONENT SOFTWARE SEPTEMBER 26, 2013 M A G U I R E P R O D U C T S, I N C. M A G U I R E P R O D U C T S, I N C. M A G U I R E P R O D U C T S, I N C. M A G U I R E P R O D U C T S, I N C. M A G U I R E P R O D U C T S, I N C. M A G U I R

More information

icreasepro Creaser Operators Manual

icreasepro Creaser Operators Manual 6-2013 Version 3.0 icreasepro Creaser Operators Manual WWW.MBMCORP.COM 800-223-2508 TABLE OF CONTENTS SPECIFICATIONS.1a SAFETY PROCEDURES/CARE & MAINTENANCE..1b COMPONENT IDENTIFICATION 2 TOUCH SCREEN

More information

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii Operator s Manual Table of Contents Operator Safety... 1 Introduction... 2 Unpacking and Setup... 3 Unpacking... 3 Setup... 4 FLYER Overview... 5 FLYER Diagram... 5 Capabilities... 5 Control Panel... 6

More information

Laboratory Mortar Mixer (Testing)

Laboratory Mortar Mixer (Testing) TomTom-Tools GmbH Zelgli 20 8905 Arni info@tomtom-tools.com Switzerland www.tomtom-tools.com User Manual Version February 22, 2015 Laboratory Mortar Mixer (Testing) 1 Introduction The Laboratory Mortar

More information

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road PROPORTIONING VALVE Model 150 INSTRUCTION MANUAL March 2017 IMS Company 10373 Stafford Road Telephone: (440) 543-1615 Fax: (440) 543-1069 Email: sales@imscompany.com 1 Introduction IMS Company reserves

More information

HPICAL Operation & Data Logging Procedures. Click spacebar to advance through slides 1

HPICAL Operation & Data Logging Procedures. Click spacebar to advance through slides 1 HPICAL-15000 Operation & Data Logging Procedures Click spacebar to advance through slides 1 WARNING Always wear proper safety equipment when using high pressure equipment. Do not exceed 125 psi air pressure.

More information

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012 JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012 UNIVERSITY OF TEXAS AT ARLINGTON Nanofabrication Research and Teaching Facility TABLE OF CONTENTS 1. Introduction....2 1.1 Scope of Work.....2

More information

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73 USER MANUAL Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * *) Require software ID: DID-SW-001 1/73 Table of contents 1 General... 3 1.1

More information

Gravimetric Blenders

Gravimetric Blenders Gravimetric Blenders GB and WSB models with 4-component control Installation Maintenance Operation Troubleshooting Instant Access Parts and Service (800) 458-1960 (814) 437-6861 www.conairnet.com The Conair

More information

ACV-10 Automatic Control Valve

ACV-10 Automatic Control Valve ACV-10 Automatic Control Valve Installation, Operation & Maintenance General: The Archer Instruments ACV-10 is a precision automatic feed rate control valve for use in vacuum systems feeding Chlorine,

More information

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments Pegas 4000 MF Gas Mixer InstructionManual Contents I Table of Contents Foreword Part I Introduction 1 2 1 System overview... 2 2 Specifications... 3 Part II Installation 4 1 Rear panel connections...

More information

Quick Start Setup Instructions for Raven LRC & AgXcel Harness for NH3 Profile plus GX40 Synergist

Quick Start Setup Instructions for Raven LRC & AgXcel Harness for NH3 Profile plus GX40 Synergist PLEASE NOTE: Your setup may vary. These screen shots represents a typical AgXcel Liquid Fertilizer System setup. See the Raven LRC Operator s Manual for safety information and additional setup and operating

More information

Manual Weighingblock VB2 series and Uniscale

Manual Weighingblock VB2 series and Uniscale Manual Weighingblock VB2 series and Uniscale Note: At page 8 in this manual you will find a short form instruction. Normally the only instruction shipped together with the Scale. Overview different ranges.

More information

Hydro-Control V User Guide

Hydro-Control V User Guide Hydro-Control V User Guide Hydronix Part no: HD0193 Version 2.3.0 Revision date: July 2006 1 COPYRIGHT Neither the whole or any part of the information contained in nor the product described in this documentation

More information

WATER CONTROL SYSTEM QUICK START

WATER CONTROL SYSTEM QUICK START SETTINGS MENU SYSTEM OPTIONS WATER LEVEL BAR GRAPH 3 DS SPRAY ON/OFF CS SPRAY ON/OFF BEACON WATER CONTROL SYSTEM QUICK START WWW.GFWORLDWIDE.COM +1 (208) 664-9291 SERVICE@GFWORLDWIDE.COM DISPLAY SCREEN

More information

A TECHNICAL REFERENCE

A TECHNICAL REFERENCE A TECHNICAL REFERENCE FOR CAREL DCM CONTROLLERS DIGITAL COMPRESSOR MODULE CANADIAN HEAD OFFICE AND FACTORY USA HEAD OFFICE AND FACTORY CANADIAN EASTERN FACTORY 1401 HASTINGS CRES. SE CALGARY, ALBERTA T2G

More information

CircuFlow Quick Setup Guide

CircuFlow Quick Setup Guide CircuFlow 5200 Quick Setup Guide LB04.0001 Rev B 20140314 TABLE OF CONTENTS Setup Therapy Setup Gradient Mode Pressure Mode Lock Device Unlock Device Treatment 03 04 05 08 11 12 13 02 SETUP 01 01 Open

More information

TYPE DOSAODOR-D SOFTWARE FOR CONFIGURATION OF TYPE DOSAODOR-D ODORANT INJECTION SYSTEM

TYPE DOSAODOR-D SOFTWARE FOR CONFIGURATION OF TYPE DOSAODOR-D ODORANT INJECTION SYSTEM User Manual Type Dosaodor-D November 2009 TYPE DOSAODOR-D SOFTWARE FOR CONFIGURATION OF TYPE DOSAODOR-D ODORANT INJECTION SYSTEM Figure 1. ROCLINK 800 Odorizer System Software D103117X012 O.M.T. www.emersonprocess.com/regulators

More information

Universal Valve Company Inc

Universal Valve Company Inc Universal Valve Company Inc 800-223-0741 www.universalvalve.com 1975-FA34 (Air Tower Troubleshooting Manual) Overview This manual has been arranged as a tool for diagnosing, and repairing Free Air Universal

More information

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual Air Bubbler Depth Gauge DG2200 Installation and Reference Manual Rev. 3.2.2 06/2011 Installation and Reference Manual Page 2 Contents Chapter 1: Installation and Overview... 3 1.1 DG2200 Location Diagram...

More information

AHE58/59 AC Servo System

AHE58/59 AC Servo System AHE58/59 AC Servo System HMI-12 User Manual Safely INstruction Please read this manual carefully, also with related manual for the machine head before use. For perfect operation and safety, installing

More information

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock Eliminator Competition Stand Alone Mode - Instruction Manual Main Menu: After startup, the Eliminator Competition will enter the Main Menu. Press the right/left arrow buttons to move through the menu.

More information

Temperature Controller CC24-7 ULTRA USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

Temperature Controller CC24-7 ULTRA USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517) Temperature Controller USER S MANUAL Aerotech, Inc. FORM: QM1387 4215 Legion Dr. Mason, MI 48854-1036 USA October 2010 Ph. (517) 676-7070 Fax (517) 676-7078 FOR CUSTOMER USE Enter the serial number located

More information

TrueBlend USER GUIDE UGB Gravimetric Blender Software Version V2.7

TrueBlend USER GUIDE UGB Gravimetric Blender Software Version V2.7 USER GUIDE UGB011-0207 www.conairnet.com TrueBlend Gravimetric Blender Software Version V2.7 USER INSTRUCTIONS About this operating manual Warranty and liability Layout of the manual Meaning of safety

More information

AFDXXX(X)AC Series Operators Manual Please read this manual thoroughly before attempting to operate your water maker.

AFDXXX(X)AC Series Operators Manual Please read this manual thoroughly before attempting to operate your water maker. AFDXXX(X)AC Series Operators Manual Please read this manual thoroughly before attempting to operate your water maker. E & O E Danger High Voltage AFDXXX(X) Series water makers operate on a 240vAC electricity

More information

StockWeigh 500 D3632 US-B

StockWeigh 500 D3632 US-B OPERATORS MANUAL DIGI-STAR 790 WEST ROCKWELL AVENUE FORT ATKINSON, WISCONSIN 53538 PHONE: (920) 563-1400 TECHNICAL SERVICE: 1-800-225-7695 (920) 563-9700 D3632 US- Rev. B August 4, 2004 StockWeigh 500

More information

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions Document Number: XE-ATA5PM-R1A UBEC 1AT AUTO TANK Fill System 08899155 Installation, Operation, & Setup Instructions Rev170906-EB-FRC PHYSICAL: 1302 WEST BEARDSLEY AVE ELKHART, IN 46514 WWW.ELKHARTBRASS.COM

More information

OMNISPORT 2000 SWIMMING QUICK REFERENCE

OMNISPORT 2000 SWIMMING QUICK REFERENCE Before During After OMNISPORT 2000 SWIMMING QUICK REFERENCE 1. Confirm that the timer is reset. 2. Set the timer to the correct event and heat. The right LCD, line 2 displays E:(event) H:(heat) R:(round)

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

DRS4-RM Manual. Set Up Instructions for DRS4 Series Single Tank

DRS4-RM Manual. Set Up Instructions for DRS4 Series Single Tank Set Up Instructions for DRS4 Series Single Tank Inspect the packaging of the equipment to confirm that nothing was damaged during shipping. (Figure 1) Remove the resin tank(s) and valve(s) from the packaging.

More information

Xactix XeF2 OPERATION MANUAL

Xactix XeF2 OPERATION MANUAL General Information The Xactix e-1 is a xenon difluoride (XeF 2) isotropic silicon etcher. XeF 2 is a vapor phase etch, which exhibits very high selectivity of silicon to photo-resist, silicon dioxide,

More information

GRUNDFOS INSTRUCTIONS. Polydos 412A. Polymer preparation system. Installation and operating instructions

GRUNDFOS INSTRUCTIONS. Polydos 412A. Polymer preparation system. Installation and operating instructions GRUNDFOS INSTRUCTIONS Polydos 412A Polymer preparation system Installation and operating instructions English (GB) English (GB) Installation and operating instructions Original installation and operating

More information

MZA 6010 Multi-Zone, Multi-Gas IR Analyzer (CO, CO 2, and CH 4 Gas Analyzer with % Carbon Calculation and Optional H 2 Measurement) Operations Manual

MZA 6010 Multi-Zone, Multi-Gas IR Analyzer (CO, CO 2, and CH 4 Gas Analyzer with % Carbon Calculation and Optional H 2 Measurement) Operations Manual MZA 6010 Multi-Zone, Multi-Gas IR Analyzer (CO, CO 2, and CH 4 Gas Analyzer with % Carbon Calculation and Optional H 2 Measurement) Operations Manual Please read, understand, and follow these instructions

More information

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale Contents Description Refer To: Scale Troubleshooting Chart Troubleshooting Error Codes Error Messages Adjustments / Repair Procedures

More information

Inventory User Guide

Inventory User Guide Inventory User Guide User Guide ~ Table of Contents ~ Sign On/Select Facility Rates & Inventory Update Tee Times Load Tee Times AutoLoad Schedule Rate Fences Dashboards Revenue At Risk, Rounds & Revenue,

More information

Annual Inspection and Calibration Checklist VAF Oilcon MK-6(M) MEPC.108(49) Page 1 of 5

Annual Inspection and Calibration Checklist VAF Oilcon MK-6(M) MEPC.108(49) Page 1 of 5 Page 1 of 5 Vessel Name: Serial number MCU: Serial Number EPU: Serial Number Skid: Mains Supply: V AC @ Hz Software version MCU: Software version EPU: K-factor Cell: K-factor Skid Flowmeter: P/L Maximum

More information

Declining Weight Blending System Quick Start Manual E Main St Marshall, IL Phone: Fax: Website:

Declining Weight Blending System Quick Start Manual E Main St Marshall, IL Phone: Fax: Website: Declining Weight Blending System Quick Start Manual 12285 E Main St Marshall, IL 62441 Phone: 217-826-6352 Fax: 217-826-8551 Website: www.yargus.com P a g e 2 MAIN SCREEN The MAIN SCREEN on the cover page

More information

Universal Valve Company Inc

Universal Valve Company Inc 1975-FA34 (Air Tower Troubleshooting Manual) Overview This manual has been arranged as a tool for diagnosing, and repairing Universal Air Towers Please read closely to identify the components that are

More information

Instructions for Use

Instructions for Use Select-380 T-Auto T-Auto Contents Page Instructions for Use Ref: 3.0 IFU 380 T-Auto Mar 18 2 Schematic layout of the doser 3 Quick-fit instructions 4 Description/Installation/Operation Pump tubes & Water

More information

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel TANK MANAGER FOR TWO TANKS OPERATING MANUAL 10/31/11 C-More T6C L color touch panel 1 TABLE OF CONTENTS GENERAL...3 INSTALLATION...4 STONE TEST PROCEDURE...7 OPERATIONAL SUMMARY...7 AUTO CARBONATION...10

More information

FRDS GEN II SIMULATOR WORKBOOK

FRDS GEN II SIMULATOR WORKBOOK FRDS GEN II SIMULATOR WORKBOOK Trotter Control Inc 2015 Document# Revision Revised 9001-0038 FRDS GEN II Simulator Workbook E 02/15/2015 by DC FRDS GEN II Simulator Workbook This workbook is a follow-on

More information

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems Corporation Issued: 5/09 P/N: 600104 Rev. 2 Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems The Gas Addition Accessory permits the

More information

WELCOME TO THE REVOLUTION

WELCOME TO THE REVOLUTION USER GUIDE WELCOME TO THE REVOLUTION THANK YOU FOR CHOOSING THE GCQUAD We listened to what you wanted - and created the most accurate, versatile and game-enhancing ball and club analysis solution available

More information

Owner's Manual Sealweld SuperSeal II Pump

Owner's Manual Sealweld SuperSeal II Pump Owner's Manual Sealweld SuperSeal II Pump By Sealweld Corporation Technical Specification Sealweld SuperSeal II Pump One (1) High Pressure Sealant/Lubricant SuperSeal II Pump: 100:1 Ratio with 10,000 psi

More information

New product release. Universal Rebreather Monitor (URBM) Three cell / Independent backup

New product release. Universal Rebreather Monitor (URBM) Three cell / Independent backup New product release Closed Circuit Research is pleased to announce the launch of our range of Universal Rebreather Monitors Universal Rebreather Monitor (URBM) Three cell / Independent backup Key features

More information

OS/OA Series Gravimetric Batch Blenders (Standard & CE Models)

OS/OA Series Gravimetric Batch Blenders (Standard & CE Models) OS/OA Series Gravimetric Batch Blenders (Standard & CE Models) Operation, Installation and Service Manual AEC/HydReclaim, Inc. 801 AEC Drive Wood Dale, IL. 60191 Tel [630] 595-1060 Fax [630] 595-8924 www.aecinternet.com

More information

Standard Operating Manual

Standard Operating Manual Standard Operating Manual Denton Explorer 14 RF/DC Sputter Version 1.0 Page 1 of 11 Contents 1. Picture and Location 2. Process Capabilities 1. Cleanliness Standard 2. Available for Sputtering Materials

More information

- Repeat calibration until desired results are reached otherwise set SW2 and SW1-8 open.

- Repeat calibration until desired results are reached otherwise set SW2 and SW1-8 open. Calibration Procedures on Cobe Centrysystem 3: I) Balance Chamber Calibration: - Verify that pressure regulators PRV and PRV2 are calibrated as well as pressure transducers PDI and PDO with switches SW2

More information

955108_2. AirForce Operator s Guide

955108_2. AirForce Operator s Guide 955108_2 AirForce Operator s Guide Contents System Setup and Operation...3 AirForce Setup...3 Load Cells...6 AirForce Control...8 How to Set AirForce...11 Home Screen...13 AirForce Diagnostic Information...15

More information

Remote Control Bait Boat

Remote Control Bait Boat CARPIO 2.0 User Manual All pictures shown are for illustration purpose only. Actual product may vary due to product enhancement Remote Control Bait Boat (Smart Remote Control at 868 MHz) 1 Table of Contents

More information

YSC-8330 USER MANUAL XI AN TYPICAL INDUSTRIES CO.,LTD.

YSC-8330 USER MANUAL XI AN TYPICAL INDUSTRIES CO.,LTD. YSC-8330 USER MANUAL XI AN TYPICAL INDUSTRIES CO.,LTD. Contents 1 Notice 1.1 Work environment 1.2 Notice of installation 1.3 Notice of safety 2 Installation and Adjustment 2.1 Controll box 2.2 Speed controller

More information

Richards Industries Basic Siemens PS2 Positioner Functions

Richards Industries Basic Siemens PS2 Positioner Functions Basic Siemens PS2 Positioner Functions Wiring 1 Supply Pressure Use clean, dry instrument air for the supply pressure. In general, on valves that are normally closed, you need 35-40 psi of supply pressure

More information

BASIC Z-STACK AND TIME SERIES SCAN ON THE ZEISS LIGHTSHEET Z. 1

BASIC Z-STACK AND TIME SERIES SCAN ON THE ZEISS LIGHTSHEET Z. 1 BASIC Z-STACK AND TIME SERIES SCAN ON THE ZEISS LIGHTSHEET Z. 1 The front door of the main body of the instrument may be open when you arrive. Take the sample chamber and slide it into position with the

More information

unconventional-airsoft.com

unconventional-airsoft.com unconventional-airsoft.com Congratulations on your new digital fire control computer! This unit will change the way you use and look at your electric gun. With this short document, you will know all you

More information

Center Command Version 3. Operations Manual

Center Command Version 3. Operations Manual Center Command Version 3 Operations Manual Version: July 26, 2010 Table of Contents OVERVIEW... 2 OVERVIEW OF COMPUTER SCORE CENTER COMMAND... 2 MAIN MENU FUNCTIONS (IF MODULES INSTALLED)... 3 CENTER

More information

HART Communications Board

HART Communications Board - HART Communications Board (Highway Addressable Remote Transducer) User Manual Document No. Sensidyne, LP. 1000 112 th Circle N, Suite 100 St. Petersburg, Florida 33716 USA 800-451-9444 +1 727-530-3602

More information

Phuel Modular Control Units

Phuel Modular Control Units Phuel Modular Phuel Modular, like our market leading Modular BOPs, provide an efficient flexible solution to suit any customer s needs. Each unit is constructed from the best of materials and supportable,

More information

IBU3 Manual Addendum 1

IBU3 Manual Addendum 1 This addendum covers the follow items. Connection of airsoft micro switch Connection of Taigen airsoft recoil units Selecting airsoft mode Settings for clutch style gearboxes Motor enable selection Confirmation

More information

Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Dump Valve Service Kit for Series 2300 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit

More information

Helium Level Measurement Unit

Helium Level Measurement Unit Helium Level Measurement Unit HLMU User Manual Version 002 The information in this manual may be altered without notice. BRUKER BIOSPIN accepts no responsibility for actions taken as a result of use of

More information

NGP-250/500 Nitrogen Generator Quick Start Guide

NGP-250/500 Nitrogen Generator Quick Start Guide NGP-250/500 Nitrogen Generator Quick Start Guide Version: A July 2013 Potter Electric Signal Company, LLC 5757 Phantom Dr., Suite 125 P. O. Box 42037 Hazelwood, MO 63042 Phone: (314) 595-6900 Document

More information

LED CONVERSION BOARD - YAKUZA SERIES EGO/GEO

LED CONVERSION BOARD - YAKUZA SERIES EGO/GEO LED CONVERSION BOARD - YAKUZA SERIES EGO/GEO The LED conversion board replaces the OLED screen mini-board on your Yakuza Series board. Combined with new firmware, your board will function similarly to

More information

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings SomnoSuite FAQ V1.3 January 2015 Setup 1. How do I connect the SomnoSuite to my oxygen source? 2. Is there a way to speed up the downward movement of the pusher block when setting the empty position? 3.

More information

Roller AC Servo System

Roller AC Servo System Safely Instruction Roller AC Servo System HMI-15 User Manual Please read this manual carefully, also with related manual for the machinery before use the controller. For installing and operating the controller

More information

FX134, FX1234, FX3030 Problem and Solutions

FX134, FX1234, FX3030 Problem and Solutions FX134, FX1234, FX3030 Problem and Solutions Unit Will Not Power Up Turn the power switch on. The unit LCD will display revision program and filter life within 3 to 5 seconds after turning on unit. If this

More information

XC2 Client/Server Installation & Configuration

XC2 Client/Server Installation & Configuration XC2 Client/Server Installation & Configuration File downloads Server Installation Backup Configuration Services Client Installation Backup Recovery Troubleshooting Aug 12 2014 XC2 Software, LLC Page 1

More information

TECH TIPS TZ34/20 & TZ50/30. Service Call: Machine will not automatically level. Tools Needed: Multi Meter Jumper wire 7/16 Combination wrench.

TECH TIPS TZ34/20 & TZ50/30. Service Call: Machine will not automatically level. Tools Needed: Multi Meter Jumper wire 7/16 Combination wrench. Service Call: Machine will not automatically level. Tools Needed: Multi Meter Jumper wire 7/16 Combination wrench Model: TZ34/20 & TZ50/30 Tech Tips Safety Rules Danger Failure to obey the instructions

More information

Stone Container 987 Auger Packer Manual

Stone Container 987 Auger Packer Manual Stone Container 987 Auger Packer Manual SAFETY INSTALLATION OPERATION MAINTENANCE, Ltd. (512) 352-3694 Phone (512) 352-3648 Fax 1 Table of Contents Topic Reconditioned Machine Information Page Insert Chapter

More information

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408) RACEAMERICA T i m i n g S y s t e m s Demo Tree Controller Owner s Manual Models 3204D, 3204DW & 3204DX Rev D RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA 95055-3469 (408) 988-6188 http://www.raceamerica.com

More information

Design Envelope Booster. Sequence of operation

Design Envelope Booster. Sequence of operation Design Envelope Booster Sequence of operation File No: 62.835 Date: february 11, 2015 Supersedes: 62.835 Date: july 11, 2014 sequence of operation Design Envelope Booster 2 general The packaged domestic

More information

USER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

USER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM USER MANUAL OPERATION AND THE USE OF A CAR WITH Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM Page 2 / 8 Table of csontents 1. STARTING THE ENGINE... 3 2. CONTROL PANEL... 3 2.1 Indication of the current

More information

A4s Operation Manual

A4s Operation Manual A4s Operation Manual Safety Instruction Please read this manual carefully, also with related manual for the machinery before use the controller. For installing and operating the controller properly and

More information

PARAMOUNT FITNESS 7.55T/7.85T Treadmill Owner s Manual

PARAMOUNT FITNESS 7.55T/7.85T Treadmill Owner s Manual PARAMOUNT FITNESS 7.55T/7.85T Treadmill Owner s Manual Safety Warnings... 4 Introduction... 7 Overview... 7 Power Requirements... 8 Service and Support Information... 9 Initial Setup... 10 Warnings...

More information

Sterisil Ac+ Installation & Operating Manual

Sterisil Ac+ Installation & Operating Manual Sterisil Ac+ Installation & Operating Manual 719 622 7200 Sterisil.com Arbor Dental Associates 2 Table of Contents Introduction 4 Sterisil Ac + Features 5 Installation Instructions 6 Maintenance 10 Troubleshooting

More information

1 STARTUP Overview Buttons Basics of Control Resetting Faults and Alarms OPERATION...

1 STARTUP Overview Buttons Basics of Control Resetting Faults and Alarms OPERATION... Operation & Service Manual 940126-0002 pco 3 Programmable Logic Controller Contents 1 STARTUP...1 1.1 Overview... 1 1.1.1 Buttons... 1 1.1.2 Basics of Control... 1 1.2 Resetting Faults and Alarms... 2

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS 2000 Dionex Corporation Document No. 031277 Revision 03 April 2000 2000 Dionex Corporation All rights reserved worldwide. Printed in the United States of

More information

Version 1.0. icrease pro + Serial Number. Date

Version 1.0. icrease pro + Serial Number. Date icrease pro + 6-2016 Version 1.0 Serial Number Date This page is intentionally blank CONTENTS SPECIFICATIONS. 1a SAFETY PROCEDURES/CARE & MAINTENANCE..... 1b COMPONENT IDENTIFICATION.... 2 TOUCH SCREEN

More information

SwimNumber App. Build Custom Smart Workouts Control the Wave Propulsion TM System Achieve Health and Fitness Goals INSTRUCTION MANUAL

SwimNumber App. Build Custom Smart Workouts Control the Wave Propulsion TM System Achieve Health and Fitness Goals INSTRUCTION MANUAL SwimNumber App Build Custom Smart Workouts Control the Wave Propulsion TM System Achieve Health and Fitness Goals INSTRUCTION MANUAL Table of Contents Warning...2 Connecting to Swim Spa...3-7 Swim Spa

More information

PTG100 Precision Test Gauge

PTG100 Precision Test Gauge PTG100 Precision Test Gauge User Manual PD1007 Rev B 03/28/2014 Palmer Instruments Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free: 800-421-2853 Phone: 828-658-3131 Fax: 828-658-0728 Email:

More information

[MYLAPS INTEGRATION]

[MYLAPS INTEGRATION] 2018 The Race Director MyLaps Integration Manual [MYLAPS INTEGRATION] This document explains how to manage the results data between your MyLaps readers and Race Director using manual file transfers. Contents

More information

SMTmax Corp. AE-3090D Automatic Stencil printer. User Manual

SMTmax Corp. AE-3090D Automatic Stencil printer. User Manual SMTmax Corp. AE-3090D Automatic Stencil printer User Manual SMTmax Corporation 5675 Kimball CT, Chino California 91710 www.smtmax.com AE-3090D Index 1. Introduction 2. Specifications 3. Installation guide

More information

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....

More information

WARNING OLED & BASIC MENU QUICK START

WARNING OLED & BASIC MENU QUICK START Getting Started QUICK START WARNING The VANGUARD MARKER is not a toy. Careless or improper use, including failure to follow instructions and warnings within this Operator Manual and attached to the VANGUARD

More information

OEM Manual. MODEL ½ Digit DRUM SCALE

OEM Manual. MODEL ½ Digit DRUM SCALE OEM Manual MODEL 4020-3 ½ Digit DRUM SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA & Canada) Phone:

More information

ABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT Abrasive Regulator II and 800# Pot Manual

ABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT Abrasive Regulator II and 800# Pot Manual ABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT TABLE OF CONTENTS Contact Information and Customer & Technical Service... 1 1 Introduction... 1 2 Abrasive Regulator... 1 Description:...

More information

GHC 20 Owner s Manual

GHC 20 Owner s Manual GHC 20 Owner s Manual Introduction See the Important Safety and Product Information guide in the product box for product warnings and other important information. You are responsible for the safe and prudent

More information

Napa Technology Trouble Shooting. For Premier & Premier PLUS Models

Napa Technology Trouble Shooting. For Premier & Premier PLUS Models Napa Technology Trouble Shooting For Premier & Premier PLUS Models Before contacting Napa Technology for support, please check if the problem and solution are found below: Machine Is Off & All LCD s are

More information

GV Standard X-Vent. Setup, Commissioning & Installation Guide

GV Standard X-Vent. Setup, Commissioning & Installation Guide GV Standard X-Vent Setup, Commissioning & Installation Guide Technical experts in the design, manufacture and supply of precision engineered, architectural rooflights for residential and commercial buildings.

More information

Pressure Automated Calibration Equipment

Pressure Automated Calibration Equipment GE Measurement & control Pressure Automated Calibration Equipment Safety Instructions and User Guide - K0447 PACE5000 PACE6000 K0447 Issue No. 9 1 10 1 PACE5000 1 2 3 4 5 PACE6000 2 6 7 8 3 4 5 6 7 8 9

More information

System 6 Water Polo. For the System 6 Sports Timer Software User Guide. F872 Rev

System 6 Water Polo. For the System 6 Sports Timer Software User Guide. F872 Rev System 6 Water Polo For the System 6 Sports Timer Software User Guide F872 Rev. 20171114 Customer Service Department www.coloradotime.com Email: customerservice@coloradotime.com Phone: 970-667-1000 Toll

More information

SERVICE BULLETIN. TOPIC: Cylinder NUMBER: SUPERSEDES: NEW DATE: May 15, Indexing Basic Cylinder Height On CFR F-1/F-2 Rating Units

SERVICE BULLETIN. TOPIC: Cylinder NUMBER: SUPERSEDES: NEW DATE: May 15, Indexing Basic Cylinder Height On CFR F-1/F-2 Rating Units SERVICE BULLETIN TOPIC: Cylinder NUMBER: 4-013 SUPERSEDES: NEW DATE: May 15, 2004 MODELS APPLICABLE TO: TEST METHOD: ROUTE TO: F-1 Research D 2699 F-2 Motor D 2700 F-1/F-2 Combination D 2699, D 2700 F-4

More information

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021-PR Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-PR For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4

More information

PGA3510 Portable 3-Gas IR Analyzer. Operations Manual

PGA3510 Portable 3-Gas IR Analyzer. Operations Manual PGA3510 Portable 3-Gas IR Analyzer Operations Manual Please read, understand, and follow these instructions before operating this equipment. Super Systems, Inc. is not responsible for damages incurred

More information

RAM 4021-DPX Operation Manual

RAM 4021-DPX Operation Manual RAM 4021-DPX Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS ABL 4021-DPX / RAM 4021-DPX For Your Safety... 3 Description... 3 Setup Mode... 4 Lights/Alarms... 4 Operation...

More information