BACKFLOW ENCLOSURES ALUMINUM
|
|
- Constance Fleming
- 5 years ago
- Views:
Transcription
1 Low Profile Enclosure 12 SBBC-15AL SBBC-30AL SBBC-45AL SBBC-60AL High Profile Two Piece Enclosure SBBC-40AL SBBC-60AL SBBC-75AL SBBC-90AL S VANDAL-RESISTANT EASY ACCESS 100% stainless steel hardware assures long-term, rust proof Pre-punched viewing ports provide for easy inspection without removing the cover Expansion module allows for length adjustments to meet field requirements
2 INSULATED S ALL WEATHER INSULATED 100% stainless steel hardware assures long-term, rust proof R-6 insulation on the top and sides helps protect freezing* Flexible rubber skirt provides protection from wind but allows drainage *To properly protect from freezing, the use of pipe heating cable is recommended Low Profile Insulated Enclosure SBBC-15ALI SBBC-30ALI SBBC-45ALI SBBC-60ALI High Profile Insulated Two Piece Enclosure SBBC-40ALI SBBC-60ALI SBBC-75ALI SBBC-90ALI Telephone (800) FAX (888)
3 PUMP & POWER CONDITIONER ENCLOSURES VANDAL-RESISTANT EASY ACCESS PUMP & POWER CONDITIONERS ENCLOSURE 100% stainless steel hardware assures long-term, rust proof Power Conditioner Enclosure SBBC-40ALHPPC Pump Enclosure PE-40AL PE-60AL
4 S STAINLESS STEEL SMOOTH TOUCH VANDAL RESISTANT Tube and wire construction provides a smooth surface to protect against handling injury Architectural lines of the enclosure blend beautifully into the landscape environment 100% stainless steel construction assures long-term, rustproof provides easy access for service and repair Ten year limited warranty Low Profile Smooth Touch Enclosure SBBC-30SS SBBC-45SS % Stainless Steel Minimizes Surface Area for Graffiti High Profile Smooth Touch Enclosure SBBC-20SS SBBC-40SS SBBC-75SS % Stainless Steel Minimizes Surface Area for Graffiti Telephone (800) FAX (888)
5 BACKFLOW COVER SIZE CHART Febco 825YA 3/ n/a n/a n/a SBBC-15AL SBBC-30SS & CR BC-30CR n/a n/a n/a SBBC-15AL SBBC-30SS & CR BC-30CR 1 1/ n/a n/a n/a SBBC-30AL SBBC-30SS & CR BC-30CR n/a n/a n/a SBBC-30AL SBBC-30SS & CR BC-30CR 825YD 2 1/ n/a n/a SBBC-60ALHP SBBC-75SS & CR BC-75CR n/a n/a SBBC-75ALHP SBBC-75SS & CR BC-75CR n/a n/a SBBC-75ALHP SBBC-75SS & CR BC-75CR n/a n/a SBBC-90ALHP N/A N/A 860U 2 1/ n/a n/a SBBC-60ALHP SBBC-75SS & CR BC-75CR n/a n/a SBBC-75ALHP SBBC-75SS & CR BC-75CR n/a n/a SBBC-75ALHP SBBC-75SS & CR BC-75CR n/a n/a SBBC-90ALHP N/A N/A n/a n/a CALL FACTORY N/A N/A / n/a n/a n/a SBBC-40ALHP SBBC-40SS & CR BC-75CR Watts n/a n/a n/a SBBC-40ALHP SBBC-40SS & CR BC-75CR n/a n/a n/a SBBC-40ALHP SBBC-40SS & CR BC-75CR n/a n/a n/a SBBC-40WALHP N/A BC.75CR 009QT 3/ SBBC-30AL SBBC-30SS & CR BC-30CR SBBC-45AL SBBC-45SS &CR BC-45CR 1 1/ SBBC-45AL SBBC-45SS &CR BC-45CR 1 1/ SBBC-45AL SBBC-45SS &CR BC-45CR SBBC-45AL SBBC-45SS &CR BC-45CR 2 1/ n/a n/a SBBC-60ALHP SBBC-75SS & CR BC-75CR n/a n/a SBBC-60ALHP SBBC-75SS & CR BC-75CR U009AQT 3/ n/a n/a n/a SBBC-30AL SBBC-30SS & CR BC-30CR n/a n/a n/a SBBC-30AL SBBC-30SS & CR BC-30CR 1 1/ n/a n/a n/a SBBC-30AL SBBC-30SS & CR BC-30CR n/a n/a n/a SBBC-30AL SBBC-30SS & CR BC-30CR / n/a n/a SBBC-75ALHP SBBC-75SS & CR BC-75CR Wilkins n/a n/a SBBC-75ALHP SBBC-75SS & CR BC-75CR n/a n/a SBBC-90ALHP N/A N/A n/a n/a CALL FACTORY N/A N/A 575 3/ SBBC-30AL SBBC-30SS & CR BC-30CR SBBC-30AL SBBC-30SS & CR BC-30CR 1 1/ SBBC-45AL SBBC-45SS &CR BC-45CR 1 1/ SBBC-45AL SBBC-45SS &CR BC-45CR SBBC-45AL SBBC-45SS &CR BC-45CR 2 1/ n/a n/a SBBC-60ALHP SBBC-75SS & CR BC-75CR n/a n/a SBBC-60ALHP SBBC-75SS & CR BC-75CR n/a n/a SBBC-75ALHP SBBC-75SS & CR BC-75CR n/a n/a SBBC-90ALHP N/A N/A 975 3/ SBBC-30AL SBBC-30SS & CR BC-30CR SBBC-30AL SBBC-30SS & CR BC-30CR 1 1/ SBBC-45AL SBBC-45SS &CR BC-45CR 1 1/ SBBC-45AL SBBC-45SS &CR BC-45CR SBBC-45AL SBBC-45SS &CR BC-45CR 2 1/ n/a n/a SBBC-60ALHP SBBC-75SS & CR BC-75CR n/a n/a SBBC-60ALHP SBBC-75SS & CR BC-75CR n/a n/a SBBC-90ALHP SBBC-75SS & CR BC-75CR n/a n/a CALL FACTORY N/A N/A SBBC-30AL* 25.0 SBBC-40ALHP 34.0 SBBC-45AL* 39.5 SBBC-60ALHP 54.0 SBBC-60AL* 54.0 SBBC-75ALHP 69.0 SBBC-90ALHP 84.0 Maximum Inside Clearance For Strong Box Covers SBBC-20SS 17.0 SBBC-30CR* 25.0 SBBC-30SS* 25.0 SBBC-40CR 35.5 SBBC-40SS 35.5 SBBC-45CR* 39.5 SBBC-45SS* 39.5 SBBC-75CR 69.0 SBBC-75SS 69.0 BC-30CR* 27.0 BC-45CR* 42.0 BC-75CR 72.0 *Note: Allow clearance for enclosure pivot. 18
FASTENERS, CLAMPS & STRAPS
Bands...169 Buckles...170 Cable Ties...171 Clip, Ring & Pin Kits...168 Clips, Rings & Pins...168 Hose Clamps...170,171 Screw Anchor Expanders...168 Strap Tensioners & Adaptors...172 Tie Wire...172 Tie
More informationMarschalk Model # 94000
Marschalk Model # 94000 12-volt DC Portable oil-less Air Compressor Operation Manual 27250006 REV 1 9/13/05 Table of Contents CHAPTER 1: SYSTEM DESCRIPTION... 5 FUNCTION AND THEORY... 5 SYSTEM COMPONENTS...
More informationQUALITY ALUMINUM BOAT LIFTS, INC. INSTRUCTIONS. Dominator Lake Lift
INSTRUCTIONS Dominator Lake Lift PHONE:251-986-3882 * FAX:251-986-3136 QABLDOMINATORINST.2014 P a g e 1 Quality Aluminum Boat Lifts, INC. Installation Instructions: Dominator Lake Lift Thank you for your
More informationTECHNICAL DATA. Trimpac 257a. September 16, 2013
September 16, 2013 Trimpac 257a 1. DESCrIpTION DESCRIPTION The Viking Double SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-2 and D-2B used with either a Model E or F Deluge Valve (A.1), a Viking
More informationField Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.
Description: The High Efficiency Series air handlers are engineered to achieve or exceed today s demanding energy rating requirements. Specifically designed for horizontal mounting into a furred down ceiling.
More informationHalsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!
Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4410FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY ARE LOCATED
More informationTECHNICAL DATA. Trimpac 256a. October 31, 2013
October 31, 2013 Trimpac 256a 1. DESCRIPTION The Viking SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-1 and D- 1B used with either a Model E or F Deluge Valve (A.1), a Viking Easy Riser check valve
More informationTECHNICAL DATA. Trimpac 244a. September 16, 2013
September 16, 2013 Trimpac 244a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-1 and B-1B is a factory-assembled trim package with an electric release module in a metal enclosure. The standard trim normally
More informationHoses and Lances 20,000 PSI
Jetstream provides a full arrangement of hoses and flex lances for ultra high pressure waterblasting. The hoses and lances are designed to be durable and reliable for any 20,000 psi application. A large
More informationTECHNICAL DATA. Trimpac 251a. Spetember 16, 2013
Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release
More informationAP# TUNE-UP KIT CONTENTS Sierra # O.E. # Description Contact Set Condenser
Ignition System 18-5007 AP# 13341 TUNE-UP KIT CONTENTS Sierra # O.E. # Description 18-5153 398-174 Contact Set 18-5206 398-693 Condenser 18-5008 AP# 13342 TUNE-UP KIT CONTENTS Sierra # O.E. # Description
More informationType 1367 High-Pressure Instrument Supply System with Overpressure Protection
Instruction Manual D100343X012 Type 1367 November 2017 Type 1367 High-Pressure Instrument Supply System with Overpressure Protection TYPE 252 FILTER 2ND-STAGE TYPE 67CF FILTER-STYLE REGULATOR INLET TYPE
More informationAdvantage Lockers & Bike
Advantage Lockers & Bike Advantage Bike Racks & Lockers Inc. is the #1 supplier of Storage Lockers and Bike Racks to the Lower Mainland s residential construction industry. With 25+ years of experience
More informationPNEUMATIC CONNECTORS SELECTION
PNEUMATIC CONNECTORS SELECTION Basic Model Diameter Inches (mm) Round Pneumatic Selection Chart No. of Tubes on Tubulation Diameter Inches (mm) Page Rating (psi)* 19 M & F. 460 (11.7) 19.040 (1.02) 8 100
More informationAgpro. Flush Valves TECHNICAL DATA / SPECIFICATIONS / APPLICATION GUIDE
TECHNICAL DATA / SPECIFICATIONS / APPLICATION GUIDE www.agprousa.com Over 20 types to satisfy all your flushing needs. Agpro Flush Valves are fully operational units designed for one purpose, flushing
More information700 SERIES BMS II BUBBLER MONITORING SYSTEM
1 700 SERIES BMS II BUBBLER MONITORING SYSTEM VISIT OUR WEBSITE AT SIGMACONTROLS.COM 700 SERIES BMS II MANUAL 062114 2 TABLE OF CONTENTS INTRODUCTION 3 Physical Specifications WIRING 5 PROGRAMMING & SETUP..
More informationHalsey Taylor Owners Manual STOP!
Halsey Taylor Owners Manual 4710 Freeze Resistant Floor Mounted Steel Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4710FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY
More informationTECHNICAL DATA. TRIMPAC Model B-5 & B-5B
September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on
More information5 year warranty. Comprehensive selection available. Platforms, Flask Clamps, Tube Racks. VWR Shaker Accessories
5 year warranty Comprehensive selection available Platforms, s, Tube Racks VWR Shaker Accessories VWR Platforms Universal Platforms Allows for mounting of flask clamps, test tube racks, and bottle clamps
More informationWaterSource Heat Pump Hose Kit Performance Specification-Summary
WaterSource Heat Pump Hose Kit Performance Specification-Summary AUTOMATIC & MANUAL BALANCING HOSE KITS Contractor shall provide and install Hays Hose Kits. Each kit, shall include a Hays 2500 Series Mesurflo
More informationTECHNICAL DATA. Trimpac 247a_Euro. September 16, 2013
September 16, 2013 Trimpac 247a_Euro 1. DESCRIPTION DEsCrIpTIoN TRIMPAC Model B-11 LPCB Type 1 is a factory assembled trim package for a single interlocked electric release module in a metal enclosure.
More informationSimple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18
The Bray Simple Set Max is a flanged pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SSM Series combines high rangeability
More informationAquor House Hydrant V2
Aquor House Hydrant V2 IN-WALL OUTDOOR FAUCET SYSTEM FLUSH-MOUNT QUICK-CONNECT SELF-DRAINING ANTI-SIPHON NON-FREEZE VBH-SERIES AQUOR HOUSE HYDRANT V2: WALL HYDRANT / FREEZELESS SILLCOCK Freezeless sillcock
More informationHydrotherapy Jets System for a Fiberglass Pool
Page 1 of 5 Parts List 1-50 Flex PVC pipe 2-1 1 / 2 " Ball Valves 4-1/2" 90 degree elbows 4 - Lengths of 1/2" PVC 4 - Jet bodies 4 - Jet nozzles 6 - Female slip/female slip unions 2 - Female slip/fpt union
More informationInstallation. Heat Trace Combination Drench Shower and Eyewash Unit (includes 120 V and 208/240 V versions) S19-304GA
Heat Trace Combination Drench Shower and Eyewash Unit (includes 120 V and 208/240 V versions) Top or Bottom Supply General Area Table of Contents Pre-Installation Information... 2-3 Components...4 Supplies
More informationHomestead Series 820 AWWA Butterfly Valves
Homestead Series 820 AWWA Butterfly Valves Dependable Valves for Water & Wastewater Service BODY: The ductile iron body meets or exceeds the design strength requirements of the AWWA C504 standards. Flange
More informationSimple Set. Pressure Independent Control Valves 2 Way 1/2-2
The Bray Simple Set is a threaded pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SS Series combines high rangeability control
More informationBooster Regulator/Air Tank
Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed
More informationSeries 867. Reduced Pressure Zone Assemblies " 3" (65 80mm)** INDEX. Testing INSTALLATION INSTRUCTIONS WARNING NOTICE NOTICE !
INSTALLATION INSTRUCTIONS RP/IS-F-867 Series 867 Reduced Pressure Zone Assemblies 2 1 2" 3" (65 80mm)** INDEX 867-NRS Installation Guidelines 2-3 Service, Repair and Maintenance 4-5 Test Procedure for
More informationPULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS
PULSATION / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS FUNCTIONS: 1. Pulsation Dampener smooths pump flow 2. Surge Suppressor absorbs shocks and vibrations 3. Water Hammer Arrestor eliminates
More informationD. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER
. ACCESSORIES AAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANLES & LIFT CORS GALVANIC PROTECTION KITS MUSHROOM STRAINER SLUGE STRAINERS NEMA 4 WATERTIGHT CONTROL & UAL LEVEL CONTROL (Replaces
More informationFood Service Industry Hose
Food Service Industry Hose Intro... -2 Clearforce - NR... -3 Clearforce - R... -4 Aquaforce... -5 rey Food Transfer... -6 Lion Food Transfer... -7 Dry Bulk Food Discharge... -8 EATON Industrial Hose and
More informationTECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.
Foam 302 a 1. DESCRIPTION (Refer to Figure 1 on page 302 e.) The Viking Low-Flow Foam/Water Proportioning System is a UL Listed and FM Approved system, for use with 3M and Viking brand foam concentrate.
More information$ Plan Review Fee when Permit Application is submitted HOT TUBS AND SPAS BUILDING PERMIT APPLICATION. COST: $80.
Community Development 1050 W Romeo Rd, Romeoville, IL 60446-1530 (815) 886-7200 Fax #: (815) 886-2724 Email: buildinginspections@romeoville.org HOT TUBS AND SPAS BUILDING PERMIT APPLICATION Application
More information780S Ultra High Purity Series
Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no seperate temperature or pressure inputs required Field adjustment of critical flow meter settings via on-board
More informationTECHNICAL DATA. than the water inlet pressure to the concentrate
Foam102a 1. DESCRIPTION The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with 3M foam concentrates. This system consists of a standard wet pipe sprinkler
More informationProduct Specifications Specialty Junction Boxes
NOVA Energy & Automation Product Specifications Specialty Junction Boxes Model JB 03 January 2012 Product Description 1. Specialty Junction Boxes Nova Junction Boxes are custom manufactured by size, material,
More informationAMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS
AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS DESIGNED TO HOLD THE WEIGHT FOR ELECTRICAL CABLE AS IT HANGS IN VERTICAL, SLOPING OR HORIZONTAL POSITIONS. EASILY INSTALLED AND REMOVED USING NO
More informationRecommended Flexible Pipe Installation For Rental Chillers
Installation, Operation and Maintenance Manual IOM 1159 Group: MQFS Chiller Rental Effective: June 2012 Supersedes: New Recommended Flexible Pipe Installation For Rental Chillers Angus Super Aquaduct flexible
More informationFull Range Pressure Compensating Variable Flow Control
Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever
More informationREPAIR ACCESSORIES. Part Number Qty Description. ZTCBV /8 MIP X 1/4 FIP Leaded Brz Test Cock. TCBV012LF 1 1/8 MIP X 1/4 FIP Lead Free Test Cock
REPAIR ACCESSORIES ZTCBV02 /8 MIP X /4 FIP Leaded Brz Test Cock TCBV02LF /8 MIP X /4 FIP Lead Free Test Cock ZTCBV025 /4 MIP X /4 FIP Leaded Brz Test Cock TCBV025LF /4 MIP X /4 FIP Lead Free Test Cock
More information973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS
Precise and Stable SF 6 Gas Analyzer Simultaneous measurement of humidity, SF 6 purity and SO 2 concentration Integrated gas recovery system with automatic pump back Fully automated SF 6 gas testing Fundamental
More informationFTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL
FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL TABLE OF CONTENTS PRODUCT OVERVIEW 2 I - USE AND CARE: 3 II - INSTALLATION: 5 III - GENERAL MAINTENANCE TIPS: 5 IV - APPENDIX: A-1 2-WIRE CURRENT LOOP
More informationBackflow Devices Branch Make Model Size Serial Location
Additional Information Fire Protection Systems Maintenance Services CML 18-007 The additional information below will clear up some of the questions from the branch visits. All Limited systems require 2
More informationFlexible Metal Hose Products
Flexible Metal Hose Products Specialty Flexible Hose Solutions of Stainless Steel The AEROCOM Advantage Aerocom offers engineered solutions that address specific flexible piping challenges such as vibration,
More informationProduct Data CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW DESIGN FEATURES
CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW Product Data CAPVP / CARVP A06001 A06002 CAPVU / CARVU The CAPVP, CARVP, CAPVU, and CARVU evaporator coils incorporate
More informationLAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)
LAKOS Waterworks PWC Series Sand Separators Installation & Operation Manual LS-829 (10/12) Table of Contents Separator Operation... 3 Individual Model Details.... 4 Flow vs. Pressure Loss Chart 4 Installation
More informationProduct Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment
Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment 1. Application Emergency eyewash and eye/face wash equipment are prescribed first aid installations for workplaces
More informationModel PDT Dewpoint Transmitter
Model PDT Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk
More informationSizing Enclosures for SCR Power Controllers
INTRODUCTION Application Note 1002 Sizing Enclosures for SCR Power Controllers Author - George A. Sites, AMETEK HDR Power Systems Most applications for SCR Power Controllers require some type of enclosure.
More informationFLEXIBLE SHAFTING (Wet & Dry)
TM-5 April 5, 2004 Elliott offers a complete line of precision tube tools, including: tube expanders Boiler Expanders Heat Exchanger Expanders Condenser Expanders Refinery Expanders tube rolling motors
More information61R2 STANDARD REGULATOR COMPACT REGULATOR. Phone Fax
6R STANDARD REGULATOR COMPACT REGULATOR 496 Phone 7.63.888 Fax 7.63.690 6R AND 496 REGULATORS General Information The Model 6R and 496 Compact Regulator (CR) are designed to deliver reliable and safe regulation
More informationHOW TO NOT MEASURE GAS - ORIFICE. Dee Hummel. Targa Resources
HOW TO NOT MEASURE GAS - ORIFICE Dee Hummel Targa Resources Introduction Measuring natural gas is both a science and an art. Guidelines and industry practices explain how to accurately measure natural
More informationBIMBAR INFLATABLE PACKERS AND ACCESSORIES
BIMBAR INFLATABLE PACKERS AND ACCESSORIES Geopro supplies a complete range of inflatable packers in nine different diameters from 28 up to 170mm. All our packers made of BIMBAR rubber technology are reinforced
More informationVIAK GROUP OFFICE PARTITIONING SOLUTIONS
VIK GROUP OFFICE PRTITIONING SOLUTIONS VIK GROUP OFFICE PRTITIONING SOLUTIONS PROFILE VIK Partition Systems are designed to meet the particular needs of office, corporate, commercials, healthcare and banking.
More informationambiente Installation Guide AmbiPlate more than underfloor Customer: Project: Project Reference: Date:
ambiente more than underfloor Customer: Project: Project Reference: Installation Guide AmbiPlate 0 0 Date: Ambiplate installation guide AmbiPlate Series Contents Designed for joisted/battened floors Maximum
More informationFor optimal strength and durability, we use a co-extrusion process of 3 different PVCs in the manufacturing of our pool cover slats.
2.1. Covrex Classic Covrex Classic Slats With ISO standard 1183 certification, Covrex pool covers have undergone an extensive series of tests including: Thermal coefficient of expansion testing; Elasticity
More informationTHERM-O-MIX STATION/WWM TEMPERED WATER SUPPLY
ISO9001 THERM-O-MIX STATION/WWM TEMPERED WATER SUPPLY Name: S/N: Date: V3 Diaphragm Valve V1 Mixing Valve 1 NPT Inlets V4 Final Water Temperature Control Valve 1-1/4 NPT Outlet Union ThermOmegaTech, Inc.
More informationInstallation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual ehtx Series High Efficiency Separators 1365 North Clovis Avenue Fresno, California 93727 2282 (559) 255 1601 info@lakos.com www.lakos.com LS-926A (2/13)
More informationGrundfos GT TANK Keep it safe
GRUNDFOS GT TANK Grundfos GT TANK Keep it safe Long-life tanks for all needs Grundfos pressure tanks are all ideally suited and approved for use with drinking water. The material used ensures that there
More informationGEMS SENSORS & CONTROLS
GEMS SENSORS & CONTROLS OPERATING & INSTALLATION INSTRUCTIONS 31XX / 32XX SERIES PLEASE READ CAREFULLY BEFORE INSTALLING Part Number: 560550-0076 Issue: E INTRODUCTION Series 3100/3200 high output pressure
More informationMODEL WEIGH MODULE
MODEL 65082 WEIGH MODULE INSTALLATION & OPERATING MANUAL P.O. Box 775 - Farmington, NH 03835 Tel: 603-755-3885 email: cands_nh@msn.com www.candscontrols.com Model 65023 Cantilever Beam Transducer Nickel-Plated
More informationMSA Cairns FIRE HELMET PRODUCT SPECIFICATION
MSA Cairns FIRE HELMET PRODUCT SPECIFICATION PRODUCT TYPE: Structural Firefighting Helmet PRODUCT MODEL(S): PURPOSE: To supply a uniform, standard product specification for a thermoplastic structural fire
More informationProduct Data CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE CAPMP / CARMP CAPMP / CARMP (3619, 4823, 6025)
CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE Product Data (3619, 4823, 6025) A06009 A07904 The CAPMP and CARMP evaporator coils incorporate proven standards for reliable system operation and
More informationMPM426W/436W Submersible Level Transmitter
/436W Submersible Level Transmitter Features Full sealed stainless steel construction for submersible part; sensor and amplifier circuit are all in the sealed housing; protection class IP68; Aluminum-alloy
More informationFurther technical information is available on
1 of 5 Manufacture address : Bartec Technor AS Dusavikveien 39 4007 Stavanger Norway Further technical information is available on www.bartec-technor.no Note on instructions When working in hazardous areas,
More informationRenewables. Tribune HE Unvented Hot Water Cylinders Installation and Maintenance Instructions. Issue 17 July 2012
Renewables Tribune HE Unvented Hot Water Cylinders Installation and Maintenance Instructions Issue 17 July 2012 IMPORTANT NOTE TO THE INSTALLER Read these instructions before commencing installation. Unvented
More informationAIR DRIVEN LIQUID PUMPS AIR DRIVEN AIR AMPLIFIERS AIR DRIVEN GAS BOOSTERS HIGH PRESSURE VALVES, FITTINGS AND TUBING TEST AND CALIBRATION EQUIPMENT
AIR DRIVEN LIQUID PUMPS AIR DRIVEN AIR AMPLIFIERS AIR DRIVEN GAS BOOSTERS HIGH PRESSURE VALVES, FITTINGS AND TUBING TEST AND CALIBRATION EQUIPMENT MAXIMATOR GmbH MAXIMATOR is one of the world leading manufacturers
More informationElectrical Tapes Selection Guide. 3Innovation
Electrical Tapes Selection Guide Innovation M Electrical Tape Chart PRODUCT NAME PRODUCT TAPE SIZES TEMPERATURE TYPICAL DESCRIPTION THICKNESS AVAILABLE RATING APPLICATIONS Vinyl Electrical Tapes Scotch
More informationFlow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS880 (retrofit kit) 4/275. Overview
Siemens G 2010 Overview pplication Irrigation systems Irrigation distribution systems Pumping stations Canal laterals On-farm outlets Water well production rip and sprinkler irrigation Center pivot systems
More informationSpecialprofiler / Special profiles
EPDM 30.262S 30.WI660 5 Art. A (mm) B (mm) Hardness Min. order (m) Adhesive 40 30.29168 12 1 SH 65 2.000 X 30.A018615 18,6 1,5 SH 65 30.601 * 65 2,5 SH 65 500 30.600 30 3 SH 65 30.602 50 3 SH 65 30.12932-3
More informationV43 Pressure Actuated Water Regulating Valve
FANs 125, 121 Product/Technical Bulletin V43 Issue Date 0996 V43 Pressure Actuated Water Regulating Valve The V43 Pressure Actuated Water Regulating Valves are designed to regulate water flow for water-cooled
More informationVertical and Horizontal Bladder Tanks
DATA SHEET Vertical and Horizontal Tanks Application The ANSUL bladder tank is one component in a balanced pressure proportioning system. Its operation requires no external power other than a pressurized
More informationSeries 58 SAFETY VALVES 312
312 Series ASME AIR BRASS SAFETY SOLUTION FEATURES AND BENEFITS High quality, corrosion-resistant safety valves Optimum high flow discharge rates CRN OG-3724 S Manufactured under the regulations of the
More informationRoughneck TM Mesh Slings
Roughneck TM Slings ROUGHNECK WIRE MESH SLINGS Widely used in metalworking shops and steel warehouses where loads are abrasive, hot or tend to cut web slings Features and Benefits Promotes Safety Steel
More informationDifferential Pressure Control Types MP 54, MP 55 and MP 55A
MAKING MODERN LIVING POSSIBLE Data sheet Differential Pressure Control Types MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure controls are used as safety switches to protect refrigeration
More information92831 TEL: (714) FAX:
Document N0. 1800-03 Copyright 2010 Terra Universal Inc. All rights reserved. Revised Sept. 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX:
More informationTECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1
Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a
More informationAnti-flood device Model B-1
December 4, 2009 Dry Systems 123a 1. DESCRIPTION The Anti-flood Device is required when Viking accelerators are installed on dry systems according to Viking Model E-1 Accelerator Trim Charts. In the SET
More informationVTL VFL VCL. Low Profile Series V RIGGING & ASSEMBLY INSTRUCTIONS
VTL VFL VCL Low Profile Series V RIGGING & ASSEMBLY INSTRUCTIONS Low Profile Series VL units should be rigged and installed as outlined in this bulletin. These procedures should be thoroughly reviewed
More informationTECHNICAL DATA. Q = C v P S
Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationSubpart E. Pressure Testing
Subpart E Pressure Testing 195.300 Scope This subpart prescribes minimum requirements for pressure testing of steel pipelines. However, this subpart does not apply to movement of pipe covered by 195.424.
More informationSAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER
SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SUPPLIMENT TO eom IMPORTANT READ THIS MANUAL BEFORE PRODUCT INSTALLATION, OPERATION, INSPECTION & MAINTENANCE Tougher and more rigid guidelines are being established
More informationSWIRLFLO Refrigerated fountains with FLEXI-GUARD
TM INSTALLATION, CARE & USE MANUAL SWIRLFLO Refrigerated fountains with FLEXI-GUARD TM INSTALLER! CAUTION: Review these instructions before beginning installation. Be sure that installation conforms to
More informationDescription Length Width Thickness Max. Bundle Tensile Strength Screw Size Qty./Bag Cat. No.
Mounting Head Ties Natural & UV Black Cable Ties Secures and positions wire bundles, cables, hoses, etc. to panels or other surfaces with one fastener to reduce time and cost Allows bundling before and
More informationOwners Manual. Models 4420BF1U & 4420BF1L Floor Mounted Bi-Level Bottle Filler Tubular Fountain
Owners Manual Models 4420BF1U & 4420BF1L Floor Mounted Bi-Level Bottle Filler Tubular Fountain Models (LK)4420BF1U* Models (LK)4420BF1L* INSTALLER 4420BF Fountains are among the easiest to install Fountains
More informationTHE VORTEX SLIDE OWNER S MANUAL
THE VORTEX SLIDE OWNER S MANUAL CORPORATE HEADQUARTERS WESTERN SALES AND MANUFACTURING PLANT P.O. Box 400 1017 SW Berg Parkway Canby, Oregon 97013 Phone: (503) 266-2231 Fax: (503) 266-4334 www.srsmith.com
More informationS&S. Installation Instructions: S&S Stealth Air Cleaner Kit for Harley-Davidison Models With Stock Cable Operated Delphi EFI
Instruction 510-0388 01-11-16 Version 1 Copyright 2016 by S&S Cycle, Inc. All rights reserved. Printed in the U.S.A. S&S Cycle, Inc. 14025 Cty Hwy G PO Box 215 Viola, Wisconsin 54664 Phone: 608-627-1497
More informationStandard Gas Countertop Griddle
Standard Gas Countertop Griddle This manual contains important information regarding your unit. Please read the manual thoroughly prior to equipment set-up, operation and maintenance. Failure to comply
More informationBioAerosol Nebulizing Generator. Operation and Maintenance User Manual
BioAerosol Nebulizing Generator Operation and Maintenance User Manual INTRODUCTION The BANG or BioAerosol Nebulizing Generator is a unique nebulizer for the generation of aqueous aerosols at a low air
More informationAlbany Connecticut Vermont Westchester
Natural Gas Sampling Sample Cylinders Grab Sample Panels Natural Gas field sampling is performed to determine gas composition, specific gravity, hydrocarbon dew point and natural gas value. Accurate gas
More informationESSENTIALS OF BIKE. Selecting and installing bicycle parking that works PARKING 3 B D4-3
ESSENTIALS OF BIKE PARKING Selecting and installing bicycle parking that works.375.375 1.5 5 18 PARKING 2.75 2.75 * 5 5 4 3 B ** 3.875 3.875.75 2 4 12 D4-3 BICYCLE RACK SELECTION PERFORMANCE CRITERIA FOR
More informationPAGE (Rev. A - 06/17)
Owners Manual Models 4420BF1UDBFR* and 4420BF1LDBFR* Bi-Level Tubular Bottle Filler Fountain with Pet Fountain and Sanitary Freeze Resistant Triple Valve Control Assembly MODEL (LK)4420BF1UDBFR MODEL (LK)4420BF1LDBFR
More informationBig Ride ASSEMBLY AND INSTALLATION INSTRUCTIONS * * C A U T I O N * *
Big Ride ASSEMBLY AND INSTALLATION INSTRUCTIONS * * C A U T I O N * * S.R. SMITH BIG RIDE SLIDES ARE MANUFACTURED FOR INSTALLATION AND USE ON INGROUND SWIMMING POOLS ONLY. THE BIG RIDE IS NEVER TO BE INSTALLED
More informationUSERS GUIDE. Where Accuracy Begins With Craftsmanship. About Your Bow. Safety. Maintenance. Storage
USERS GUIDE About Your Bow Safety Maintenance Storage Where Accuracy Begins With Craftsmanship Born on Date Congratulations. We would like to say thank you for choosing Moxie Archery! It is your faith
More informationBUTTERFLY VALVES Series 800
BUTTERFLY VALVES Series 800 WARNING Before proceeding read ALL instructions and become familiar with the equipment and associated drawings. Follow ALL applicable safety regulations and codes for pressurized
More informationPRO-TOOLS 7616 INDUSTRIAL LANE TAMPA, FLORIDA PHONE FAX
INSTRUCTION SET INSTRUCTION SET DANGER PLEASE READ NEVER DO THIS!!! NEVER START BEND WITH THE TUBE TOO SHORT. TUBE MUST ALWAYS EXTEND TO END OF ALUMINUM BAR OR PAST. WHEN BENDING NEVER LET ALUMINUM BAR
More informationSlide and Turn System SF25
Profile system Frameless all-glass slide and turn system Option of flush or weathered bottom track Optionally with lateral aluminium panel profiles to close the ventilation gap The flush bottom track is
More informationTECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION
Page 1 of 6 1. DESCRIPTION The Model B-1 Anti-flood Device is required when Viking accelerators are installed on dry systems according to Viking Model E-1 Accelerator Trim Charts. In the SET condition,
More informationWinter Shut Down Procedure
Winter Shut Down Procedure Although we live in Beautiful BC, we still experience freezing temperatures. To minimize the risk of freeze damage to your irrigation system, you ll need to winterize it. Our
More information