Evaluates: MAX MAX34407 Evaluation Kit. Features. General Description. EV Kit Contents. EV Kit Photo

Size: px
Start display at page:

Download "Evaluates: MAX MAX34407 Evaluation Kit. Features. General Description. EV Kit Contents. EV Kit Photo"

Transcription

1 MAX7 Evaluation Kit Evaluates: MAX7 General Description The MAX7 evaluation kit (EV kit) provides the hardware and software graphical user interface (GUI) necessary to evaluate the MAX7 SMBus -Channel Wide Dynamic Range Power Accumulator. The EV kit includes a MAX7EWE+ installed, as well as a micro-usb cable to communicate with a PC. EV Kit Contents Assembled circuit board including MAX7EWE+ Micro-USB cable Features Easy Evaluation of the MAX7 USB HID interface Windows XP and Windows 7-Compatible Software RoHS Compliant Proven PCB Layout Fully Assembled and Tested Ordering Information appears at end of data sheet. EV Kit Photo Windows is a registered trademark and registered service mark of Microsoft Corporation. Windows XP is a registered trademark and registered service mark of Microsoft Corporation ; Rev ; 9/6

2 MAX7 Evaluation Kit Evaluates: MAX7 MA7 EV Kit Files Quick Start Required Equipment MAX7 EV kit Windows XP or Windows 7 PC USB port Micro-USB cable (included) EV kit hardware (included) Screwdriver FILE MAX7EVKSoftwareInstall.EXE Note: The.EXE file is downloaded as a.zip file. Load (to measure power) DECRIPTION Application program Note: In the following sections, software-related items are identified in bold. Text in bold refers to items directly from the install or EV kit software. Text in bold and underlined refers to items from the Windows operating system. Procedure The EV kit is fully assembled and tested. Follow the steps below to verify board operation: ) Ensure that all four jumpers on J/J are populated. ) Place the EV kit hardware on a nonconductive surface to ensure that nothing on the PCB gets shorted to the workspace. ) Prior to starting the GUI, connect the EV kit hardware to a PC using the supplied micro-usb cable or equivalent. The POWER LED (D) should be green and the COM LED (D) should be red and slowly flash orange. ) Windows should automatically begin installing the necessary device driver. The USB interface of the EV kit hardware is configured as an HID device and therefore does not require a unique/custom device driver. Once the driver installation is complete, a Windows message appears near the System Icon menu, indicating that the hardware is ready to use. Do not attempt to run the GUI prior to this message. If you do, then you must close the application and restart it once the driver installation is complete. On some versions of Windows, administrator privileges may be required to install the USB device driver. 5) Once the device driver installation is complete, visit to download the latest version of the EV kit software, MAX7EVKitSetupV..zip. Save the EV kit software to a temporary folder. 6) Open the.zip file and double-click on the.exe file to run the installer. A message box stating The publisher could not be verified. Are you sure you want to run this software? may appear. If so, click Yes. 7) The installer GUI appears. Click Next and then Install. Once complete click Close. 8) Go to Start All Programs. Look for the MAX7EVKitSoftware folder and click on MAX7EVKitSoftware.EXE inside the folder. 9) When the GUI appears, the text at the bottom-right corner of the window should display EV Kit Hardware Connected. The COM LED (D) changes to green. ) Connect a load to at least one of the power monitors (IN IN) and then click Single Read. Detailed Description of Software Software Startup If the MAX7 EV kit is connected when the software is opened, the software first initializes the hardware to communicate. Next, the software searches for all slave addresses on the IC bus and connects to the first valid slave address. Then, the GUI displays EV Kit Hardware Connected at the bottom-right corner of the window under the Maxim logo. If the EV kit is not connected on software startup, the GUI populates with default EV kit values and displays EV Kit not detected! Once the EV kit is connected, the GUI searches for slave addresses. Menu Items The Device menu item allows the user to connect to a desired device. Find Slave Addresses searches for all slave addresses connected to the IC bus. To select a device, click Select Slave Address and all the slave addresses found are shown and are selectable. Status Log The status log below the tabs displays all the actions the GUI performs. Whenever a SMBus command is read or written, the action is confirmed by the log. The log can be cleared by clicking on the Clear Log button. Maxim Integrated

3 MAX7 Evaluation Kit Evaluates: MAX7 Monitor/Graph Tab The Monitor/Graph tab sheet (Figure ) displays all the accumulator values. In the Monitor group box table, the Polled values are the Accumulator values read from PWR_ACC_ to PWR_ACC_ (h to 6h) that are converted to amps using the RSENSE value in the Control table shown in Figure. The Sampled Voltage and Average Power columns track the voltage and average power of the Polled value for each channel. All values on the tab are read when the tab is selected or when the Read button is clicked. The OC status bits are cleared after every read. Check the Auto Poll checkbox to continuously read every.s. The Data Log Controls group box contains the graphrelated controls. Graph Points displays the number of reads that have been tracked in the data log. The Sampled Voltage and Average Power values are still based on all the poll count values, to reset the Poll Count, Sampled Voltage, and Average Power values, click on the Data Log Reset button. To save all the data graphed to a CSV file, click on the Save Data button. The Average Power/Voltage button selects the Average Power or voltage to be graphed. Control/Registers Tab The Control/Registers tab sheet (Figure ) displays all the SMBus commands and their current values. In the Control group box table, the RSENSE (mω) column is the value of the resistor (RX RX) between IN+ and IN- signals. The Max Current (A) column displays the maximum current threshold converted to amps using the RSENSE value. Figure. MAX7 EV Kit GUI (Monitor/Graph Tab) Maxim Integrated

4 MAX7 Evaluation Kit Evaluates: MAX7 Figure. MAX7 Control/Registers Tab Maxim Integrated

5 MAX7 Evaluation Kit Evaluates: MAX7 Detailed Description The MAX7 automatically sequences through the channels to collect samples from the common-mode voltage and the current-sense amplifiers. The 6-bit current value and the -bit voltage value are then multiplied to create a 8-bit power value that is then written to the power accumulator. Troubleshooting All efforts were made to ensure that each EV kit works on the first try, right out-of-the-box. In the rare occasion that a problem is suspected, see Table to help troubleshoot the issue. Table. Description of Switches (SLOW & PDN) SWITCH POSITION DESCRIPTION SLOW VIO Slow Mode for Reduced Power Consumption. Fast Mode. PDN VIO GUI reading device. (Power Down) GUI stops reading device. Table. Description of LEDs (D, D) LED COLOR DESCRIPTION Red USB Power Fault: A fault occurred due to overvoltage limit, current limit, or thermal limit. D (POWER) Green USB Power: USB power supply is on. Red Communication: After the software has initialized the hardware, the LED flashes red when a command from the PC is received. D (COM) Green Initialized: Hardware has been initialized by software. Maxim Integrated 5

6 MAX7 Evaluation Kit Evaluates: MAX7 Table. Troubleshooting SYMPTOM CHECK SOLUTION GUI indicates: Hardware not found GUI indicates Read Failed! and all slave addresses are being found Is the LED labeled D red? Does the LED labeled D turn green when the GUI is running? Are any of the LEDs illuminated? If yes, then the electronic fuse is in a fault state. Inspect for electrical shorts on the PCB and make sure that the PCB is not sitting on a conductive surface. If not, then exit the GUI and try running it again. If D still does not turn green, then exit the GUI and try connecting the USB cable to a different USB port on the PC and wait for a Windows message indicating that the hardware is ready to use. Run the GUI again. If not, then the PCB may not be getting power from the USB. Try a different USB cable or a different USB port. J/ Make sure all four jumpers on J/J are populated. Component Information, PCB Layout, and Schematics See the following links for component information, PCB layout diagrams, and schematics. MAX7 EV BOM MAX7 EV PCB MAX7 EV Schematics Ordering Information PART MAX7EVKIT# TYPE EV Kit #Denotes an RoHS-compliant device that may include lead(pb), which is exempt under the RoHS requirements. Maxim Integrated 6

7 MAX7 Evaluation Kit Evaluates: MAX7 Revision History REVISION NUMBER REVISION DATE DESCRIPTION PAGES CHANGED 6/6 Initial release 9/6 Removed Monitor Current of Load section and Figure 5 For pricing, delivery, and ordering information, please contact Maxim Direct at , or visit Maxim Integrated s website at Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circuit patent licenses are implied. Maxim Integrated reserves the right to change the circuitry and specifications without notice at any time. Maxim Integrated and the Maxim Integrated logo are trademarks of Maxim Integrated Products, Inc. 6 Maxim Integrated Products, Inc. 7

8 EVKit Part Number: MAX7EVKIT# Revision: C Date Last Edited: --6 Last Edited by: Amir Mirbagheri Item Ref Designator Qty Value Description LibRef Manufacturer Manufacturer_Part_Number B BANANA_JACK BANANA JACK Deltron 57- C, C, C.μF 85 Capacitor CAP TDK Corporation CGAJX7RAK CA, CB, CC, CD, C, CA, CB, CC, CD, C, 85 Capacitor CAP C5, C6, C5 C, C, C μf 85 Capacitor CAP Taiyo Yuden EMKABJ6KD-T 5 C, C.μF 85 Capacitor CAP Murata GRMBR7AK 6 C μf 85 Capacitor CAP TDK Corporation CX7RH5K/SOFT 7 C nf 85 Capacitor CAP TDK Corporation CX7RHK 8 D LED_DUAL LED_BI-COLOR LED_DUAL Knightbright APHBMSURKCGKC 9 D COM LED_BI-COLOR LED_DUAL Knightbright APHBMSURKCGKC D SCHOTTKEY MINI-F SCHOTTKEY Panasonic - SSG DBW9L JA, JB, JC, JD CON A_T_PCB -position screw terminals 6.5mm pitch CON Phoenix Contact 7955 J Dongle Header HDR_pin CON M Headers & Wire Housing AR J USB_5PIN USB_MICRO-B USB_5PIN Molex 57- J HDR_PIN CON 5 J IC DONGLE HDR_pin CON M Headers & Wire Housing AR 6 R, RA, RB, RC, RD, R, RA, RB, RC, RD, R5, R6, R7, R, R, 6 Ω 85 Resistor RES Vishay/Dale CRCW85ZEA R 7 R, R, R.kΩ 85 Resistor RES Vishay/Dale CRCW85KFKEA 8 RA, RB, RC, RD mω 5 Resistor RES Panasonic Electronic Components ERJ-MWSFMU 9 RA, RB, RC, RD 5 Resistor RES R, R5 56Ω 85 Resistor RES Vishay/Dale CRCW8556RFKEA R kω 85 Resistor RES Vishay/Dale CRCW85KFKEA R6 5.kΩ 85 Resistor RES Vishay/Dale CRCW855KFKEA R7 kω 85 Resistor RES Vishay/Dale CRCW85KFKEA R.7kΩ 85 Resistor RES Vishay/Dale CRCW85K7FKEA 5 R, R Ω 85 Resistor RES KOA Speer RK7HATTDF 6 R5, R6 85 Resistor RES Blank Internal Part Number Programmed Internal Part Number

9 7 S, S SW SPDT SPDT_Slider SW SPDT TE Connectivity / Alcoswitch SLSPC 8 TPA IN+ TEST POINT White TEST_POINT Keystone 5 9 TPB IN+ TEST POINT White TEST_POINT Keystone 5 TPC IN+ TEST POINT White TEST_POINT Keystone 5 TPD IN+ TEST POINT White TEST_POINT Keystone 5 TPA IN TEST POINT White TEST_POINT Keystone 5 TPB IN TEST POINT White TEST_POINT Keystone 5 TPC IN TEST POINT White TEST_POINT Keystone 5 5 TPD IN TEST POINT White TEST_POINT Keystone 5 6 TPA IN_P TEST POINT White TEST_POINT Keystone 5 7 TPB IN_P TEST POINT White TEST_POINT Keystone 5 8 TPC IN_P TEST POINT White TEST_POINT Keystone 5 9 TPD IN_P TEST POINT White TEST_POINT Keystone 5 TPA IN_N TEST POINT White TEST_POINT Keystone 5 TPB IN_N TEST POINT White TEST_POINT Keystone 5 TPC IN_N TEST POINT White TEST_POINT Keystone 5 TPD IN_N TEST POINT White TEST_POINT Keystone 5 TP7 5V TEST POINT Red TEST_POINT Keystone 5 5 TP8, TP6.V TEST POINT Red TEST_POINT Keystone 5 6 TP SDA TEST POINT White TEST_POINT Keystone 5 7 TP SCL TEST POINT White TEST_POINT Keystone 5 8 TP VIO TEST POINT Red TEST_POINT Keystone 5 9 TP ADDR TEST POINT White TEST_POINT Keystone 5 5 TP SLOW TEST POINT White TEST_POINT Keystone 5

10 5 TP5 PDN TEST POINT White TEST_POINT Keystone 5 5 TP7, TP8, TP9 TEST POINT Black TEST_POINT Keystone 5 5 UA MAX7 WLP6C5PX_9 X8X6 MAX7 Maxim Integrated MAX7EWE+ 5 UB () SM9 TSSOP 6_7 SM9 TSSOP 55 U Should be programmed PIC8LF55 SOIC7PX65 8N IC+,PRGM,89 9H#K,U PICfor DS9 56 U MAX995A SOT 6 MAX995A Maxim Integrated MAX995AAUT+ 57 U MAX89B QFN7P6 8NEP MAX89B Maxim Integrated MAX89BATA+ Microchip PIC8LF55 I/SO EQ7 EICP9HU 58 X 59 Micro USB Cable shoud be included in the EVKit Box KC5A8. CE CRYSTAL_SM_.X.5 mm_a A Male to Micro USB B Male Cable OSC_CMOS_ pin AVX Tripp Lite KC5A8.CE UR5 6

11 CO PAB COB PAC PAC COC PACA PACA COCA PACB PACB COCB PACC PACC COCC PACD PACD COCD PAC PAC COC PACA PACA COCA PACB PACB COCB PACC PACC COCC PACD PACD COCD PAC PAC COC PAC PAC COC PAC5 PAC5 COC5 PAC6 PAC6 COC6 PAC PAC COC PAC PAC COC PAC PAC COC PAC PAC COC PAC PAC COC PAC PAC COC PAC PAC COC PAC PAC COC PAC5 PAC5 COC5 PAD PAD PAD PAD COD PAD PAD PAD PAD COD PAD PAD COD PAJA PAJA COJA PAJB PAJB COJB PAJC PAJC COJC PAJD PAJD COJD PAJ PAJ PAJ PAJ COJ PAJMH PAJ PAJ PAJPAJPAJ5 COJ PAJ PAJ COJ PAJ PAJ PAJ PAJ COJ PAR PAR COR PARA PARA CORA PARB PARB CORB PARC PARC CORC PARD PARD CORD PAR PAR COR PARA PARA CORA PARB PARB CORB PARC PARC CORC PARD PARD CORD PAR PAR COR PARA PARA CORA PARB PARB CORB PARC PARC CORC PARD PARD CORD PAR PAR COR PARA PARA CORA PARB PARB CORB PARC PARC CORC PARD PARD CORD PAR5 PAR5 COR5 PAR6 PAR6 COR6 PAR7 PAR7 COR7 PAR PAR COR PAR PAR COR PAR PAR COR PAR PAR COR PAR5 PAR5 COR5 PAR6 PAR6 COR6 PAR7 PAR7 COR7 PAR PAR COR PAR PAR COR PAR PAR COR PAR PAR COR PAR PAR COR PAR5 PAR5 COR5 PAR6 PAR6 COR6 CORef PAS PAS PAS COS PAS PAS PAS COS PATPA COTPA PATPB COTPB PATPC COTPC PATPD COTPD PATPA COTPA PATPB COTPB PATPC COTPC PATPD COTPD PATPA COTPA PATPB COTPB PATPC COTPC PATPD COTPD PATPA COTPA PATPB COTPB PATPC COTPC PATPD COTPD PATP7 COTP7 PATP8 COTP8 PATP COTP PATP COTP PATP COTP PATP COTP PATP COTP PATP5 COTP5 PATP6 COTP6 PATP7 COTP7 PATP8 COTP8 PATP9 COTP9 PAUAD PAUAD PAUADPAUAD PAUAC PAUAC PAUACPAUAC PAUAB PAUAB PAUABPAUAB PAUAA PAUAA PAUAAPAUAA COUA PAUB PAUB PAUB PAUB PAUB5 PAUB6 PAUB7 PAUB8 PAUB6 PAUB5 PAUB PAUB PAUB PAUB PAUB PAUB9 COUB PAU5 PAU6 PAU7 PAU8 PAU9 PAU PAU PAU PAU PAU PAU5 PAU6 PAU7 PAU8 PAU PAU PAU PAU PAU PAU9 PAU8 PAU7 PAU6 PAU5 PAU PAU PAU PAU COU PAU PAU5 PAU PAU PAU PAU6 COU PAU PAU PAU PAU PAU5 PAU6 PAU7 PAU8 PAU9 COU PAX PAX PAX PAX COX PAJ PAR PAR PATP6 PAC PAC PAC PAC PAC PAC PAJ PAR6 PAR PAR PAR PAR PAR5 PAR6 PATP8 PAU PAU PAU8 PAX PAC PAD PATP7 PAU PAU PAU PAC6 PAR7 PATP PAUAC PAUB7 PAR PAX PAC5 PAD PAJ PAR PAU PAR PAU6 PAR PAU5 PAB PAC PACA PACB PACC PACD PAC PACA PACB PACC PACD PAC PAC PAC5 PAC6 PAJ PAR7 PAS PAS PATP7 PATP8 PAUAB PAUB PAC PAC PAC PAC PAC PAC PAC PAC5 PAJ5 PAJ PAJ PAR PAR5 PAR7 PATP9 PAU8 PAU PAU9 PAU PAU PAU PAU9 PAX PAD PAU PACA PARA PATPA PAUAA PAUB6 PACA PARA PATPA PAUAA PAUB5 PAJA PARA PARA PARA PATPA PAJA PARA PARA PARA PATPA PACB PARB PATPB PAUAA PAUB PACB PARB PATPB PAUAB PAUB PAJB PARB PARB PARB PATPB PAJB PARB PARB PARB PATPB PACC PARC PATPC PAUAD PAUB PACC PARC PATPC PAUAC PAUB PAJC PARC PARC PARC PATPC PAJC PARC PARC PARC PATPC PACD PARD PATPD PAUAD PAUB9 PACD PARD PATPD PAUAD PAUB PAJD PARD PARD PARD PATPD PAJD PARD PARD PARD PATPD PAC PAU7 PAD PAR PAD PAU6 PAD PAR5 PAD PAR PAD PAR PAD PAR PAJ PAR PAJ PAR PAR5 PAS PAR6 PAS PAR PAU PAR6 PAR7 PAU6 PAR PAU9 PAC5 PAR6 PATP5 PAUAB PAUB PAJ PAR PATP PAUAC PAUB5 PAJ PAR5 PAU PAJ PAR PATP PAUAD PAUB8 PAJ PAR6 PAU PAC PAR5 PATP PAUAC PAUB6 PAC PAJ PAR PAU PAU5 PAC PAC PAR PAUAA PAUB PAC PAR PAR PAR PAS PAS PATP PAUAB PAUB PAD PAU

12 CO PAB COB PAC PAC COC PACA PACA COCA PACB PACB COCB PACC PACC COCC PACD PACD COCD PAC PAC COC PACA PACA COCA PACB PACB COCB PACC PACC COCC PACD PACD COCD PAC PAC COC PAC PAC COC PAC5 PAC5 COC5 PAC6 PAC6 COC6 PAC PAC COC PAC PAC COC PAC PAC COC PAC PAC COC PAC PAC COC PAC PAC COC PAC PAC COC PAC PAC COC PAC5 PAC5 COC5 PAD PAD PAD PAD COD PAD PAD PAD PAD COD PAD PAD COD PAJA PAJA COJA PAJB PAJB COJB PAJC PAJC COJC PAJD PAJD COJD PAJ PAJ PAJ PAJ COJ PAJMH PAJ PAJ PAJPAJPAJ5 COJ PAJ PAJ COJ PAJ PAJ PAJ PAJ COJ PAR PAR COR PARA PARA CORA PARB PARB CORB PARC PARC CORC PARD PARD CORD PAR PAR COR PARA PARA CORA PARB PARB CORB PARC PARC CORC PARD PARD CORD PAR PAR COR PARA PARA CORA PARB PARB CORB PARC PARC CORC PARD PARD CORD PAR PAR COR PARA PARA CORA PARB PARB CORB PARC PARC CORC PARD PARD CORD PAR5 PAR5 COR5 PAR6 PAR6 COR6 PAR7 PAR7 COR7 PAR PAR COR PAR PAR COR PAR PAR COR PAR PAR COR PAR5 PAR5 COR5 PAR6 PAR6 COR6 PAR7 PAR7 COR7 PAR PAR COR PAR PAR COR PAR PAR COR PAR PAR COR PAR PAR COR PAR5 PAR5 COR5 PAR6 PAR6 COR6 CORef PAS PAS PAS COS PAS PAS PAS COS PATPA COTPA PATPB COTPB PATPC COTPC PATPD COTPD PATPA COTPA PATPB COTPB PATPC COTPC PATPD COTPD PATPA COTPA PATPB COTPB PATPC COTPC PATPD COTPD PATPA COTPA PATPB COTPB PATPC COTPC PATPD COTPD PATP7 COTP7 PATP8 COTP8 PATP COTP PATP COTP PATP COTP PATP COTP PATP COTP PATP5 COTP5 PATP6 COTP6 PATP7 COTP7 PATP8 COTP8 PATP9 COTP9 PAUAD PAUAD PAUADPAUAD PAUAC PAUAC PAUACPAUAC PAUAB PAUAB PAUABPAUAB PAUAA PAUAA PAUAAPAUAA COUA PAUB PAUB PAUB PAUB PAUB5 PAUB6 PAUB7 PAUB8 PAUB6 PAUB5 PAUB PAUB PAUB PAUB PAUB PAUB9 COUB PAU5 PAU6 PAU7 PAU8 PAU9 PAU PAU PAU PAU PAU PAU5 PAU6 PAU7 PAU8 PAU PAU PAU PAU PAU PAU9 PAU8 PAU7 PAU6 PAU5 PAU PAU PAU PAU COU PAU PAU5 PAU PAU PAU PAU6 COU PAU PAU PAU PAU PAU5 PAU6 PAU7 PAU8 PAU9 COU PAX PAX PAX PAX COX PAJ PAR PAR PATP6 PAC PAC PAC PAC PAC PAC PAJ PAR6 PAR PAR PAR PAR PAR5 PAR6 PATP8 PAU PAU PAU8 PAX PAC PAD PATP7 PAU PAU PAU PAC6 PAR7 PATP PAUAC PAUB7 PAR PAX PAC5 PAD PAJ PAR PAU PAR PAU6 PAR PAU5 PAB PAC PACA PACB PACC PACD PAC PACA PACB PACC PACD PAC PAC PAC5 PAC6 PAJ PAR7 PAS PAS PATP7 PATP8 PAUAB PAUB PAC PAC PAC PAC PAC PAC PAC PAC5 PAJ5 PAJ PAJ PAR PAR5 PAR7 PATP9 PAU8 PAU PAU9 PAU PAU PAU PAU9 PAX PAD PAU PACA PARA PATPA PAUAA PAUB6 PACA PARA PATPA PAUAA PAUB5 PAJA PARA PARA PARA PATPA PAJA PARA PARA PARA PATPA PACB PARB PATPB PAUAA PAUB PACB PARB PATPB PAUAB PAUB PAJB PARB PARB PARB PATPB PAJB PARB PARB PARB PATPB PACC PARC PATPC PAUAD PAUB PACC PARC PATPC PAUAC PAUB PAJC PARC PARC PARC PATPC PAJC PARC PARC PARC PATPC PACD PARD PATPD PAUAD PAUB9 PACD PARD PATPD PAUAD PAUB PAJD PARD PARD PARD PATPD PAJD PARD PARD PARD PATPD PAC PAU7 PAD PAR PAD PAU6 PAD PAR5 PAD PAR PAD PAR PAD PAR PAJ PAR PAJ PAR PAR5 PAS PAR6 PAS PAR PAU PAR6 PAR7 PAU6 PAR PAU9 PAC5 PAR6 PATP5 PAUAB PAUB PAJ PAR PATP PAUAC PAUB5 PAJ PAR5 PAU PAJ PAR PATP PAUAD PAUB8 PAJ PAR6 PAU PAC PAR5 PATP PAUAC PAUB6 PAC PAJ PAR PAU PAU5 PAC PAC PAR PAUAA PAUB PAC PAR PAR PAR PAS PAS PATP PAUAB PAUB PAD PAU

13 R5 RA RA CA CA C.uF S SW- SPDT TP SDA VI O.V TP SCL TP VI O TP5 PDN TP ADDR TP6.V TP SL OW TP7 TP8 TPA IN+ TPA IN- TPA IN_P TPA IN_N JA CON IN- IN+ RB RB CB CB TPB IN+ TPB IN- TPB IN_P TPB IN_N JB CON IN- IN+ RC RC CC CC TPC IN+ TPC IN- TPC IN_P TPC IN_N JC CON IN- IN+ RD RD CD CD TPD IN+ TPD IN- TPD IN_P TPD IN_N JD CON IN- IN+ ADDR PDN SLOW.V SDA SCL VIO IN_P IN_N IN_P IN_N IN_P IN_N IN_P IN_N RA m RA RB m RB RC m RC RD m RD J Dongle Header SCL SDA.V VDD VI O PDN SCL 5 SL OW 6 ADDR 7 SDA 8 INP 9 INN INP INN INN INP INN 5 INP 6 UB SM9- TSSOP IN+ A IN- A IN+ A VDD A IN- B VI O B PDN B B IN- C ADDR C SL OW C SCL C IN+ D IN- D IN+ D SDA D UA MAX7 R6 S SW- SPDT C R.k R.k R VIO SDA SCL ADDR SLOW PDN IN+ IN- IN+ IN- IN+ IN- IN+ IN- VIO SDA SCL ADDR SLOW PDN VDD IN+ IN- IN+ IN- IN- IN+ IN- IN+ R VDD VDD C.uF VIO C C5 C6 B R7

14 J Vbus D- D+ I.D. 5 USB_5PI N VBUS R R R 56 D- D+ DA Red C uf 6 5 U FL AG IN ON MAX995A OUT SETI R k 5V' C uf Green 5V DB R5 56 U IN OUT BYP EN FB GS POK MAX89B C.uF.V'.V R6 5.k C R7 uf k ' TP9.V' X INH J VCC OUT OSC_CMOS_pin ' R.7k C5.V' CL K C R ed R.uF R DA COM Green R DB C nf.v' OSC R.k D VPP HB COM U MCL R P,HB COM_L ED,BOOT P P RCV P6, CS OSC OSC P UOE PS_VAR VUSB PI Cf or DS9 P8,W_PU P7,W_DQ P5 USB_DET VPO VMO P,SCK,SCL P,SDI,SDA VDD P9,SDO ENUM D+,VP D-,VM SCL ' SDA' D+ D-.V' R5 R6.V' C C uf.uf ' IC DONGL E J ' x Header is the only connection between programming board and MAX9 demo. ' ' USB to IC Programming Board

Oxygen Meter User Manual

Oxygen Meter User Manual Oxygen Meter User Manual Monday, July 23, 2007 1. Outline...2 2. Program...3 2.1. Environment for program execution...3 2.2. Installation...3 2.3. Un installation...3 2.4. USB driver installation...3 2.5.

More information

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel DTLS Manual This document contains proprietary information. Copyright 2015 Scientific Data Systems, Inc. All rights reserved. 1 Depth Tension

More information

Evaluates: MAX MAX14748 Evaluation Kit. General Description. Detailed Description of Hardware. Features. Jumper Descriptions

Evaluates: MAX MAX14748 Evaluation Kit. General Description. Detailed Description of Hardware. Features. Jumper Descriptions MAX78 Evaluation Kit Evaluates: MAX78 General Description The MAX78 evaluation kit (EV kit) is a fully assembled and tested circuit for evaluating the MAX78 USB Type-C charger. Refer to the MAX78 IC data

More information

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock Eliminator Competition Stand Alone Mode - Instruction Manual Main Menu: After startup, the Eliminator Competition will enter the Main Menu. Press the right/left arrow buttons to move through the menu.

More information

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120 MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120 QUICK START GUIDE P/N 6006154, REVISION C MAY 2013 Model 8120 Mask Integrity Tester is patented under U.S. Patent No. 8,312,761. Additional patents are pending.

More information

Wire Buddy Manual IOpath Software

Wire Buddy Manual IOpath Software Wire Buddy Manual IOpath Software Wire Buddy is a calculation reference tool for Electricians and Maintenance personnel. Wire Buddy was created for the Maintenance Electrician. There are many occasions

More information

Microsoft Windows Software Manual for FITstep Stream Version 4

Microsoft Windows Software Manual for FITstep Stream Version 4 Thank you for purchasing this product from Gopher. If you are not satisfied with any Gopher purchase for any reason at any time, contact us and we will replace the product, credit your account, or refund

More information

Blackwave Dive Table Creator User Guide

Blackwave Dive Table Creator User Guide Blackwave Dive Table Creator User Guide Copyright 2002-2009 Blackwave. All rights reserved. These materials (including without limitation all articles, text, images, logos, compilation, and design) are

More information

Stand-Alone Bubble Detection System

Stand-Alone Bubble Detection System Instruction Sheet P/N Stand-Alone Bubble Detection System 1. Introduction The Bubble Detection system is designed to detect air-bubble induced gaps in a bead of material as it is being dispensed. When

More information

Instruction Manual. BZ7002 Calibration Software BE

Instruction Manual. BZ7002 Calibration Software BE Instruction Manual BZ7002 Calibration Software BE6034-12 Index _ Index Index... 2 Chapter 1 BZ7002 Calibration Software... 4 1. Introduction... 5 Chapter 2 Installation of the BZ7002... 6 2. Installation

More information

TR Electronic Pressure Regulator. User s Manual

TR Electronic Pressure Regulator. User s Manual TR Electronic Pressure Regulator Page 2 of 13 Table of Contents Warnings, Cautions & Notices... 3 Factory Default Setting... 4 Quick Start Procedure... 5 Configuration Tab... 8 Setup Tab... 9 Internal

More information

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS WARNING THE WARRANTIES MADE BY MSA WITH RESPECT TO THE PRODUCT ARE VOIDED IF THE PRODUCT IS NOT USED AND MAINTAINED IN ACCORDANCE

More information

D-OptoLogger Dissolved Oxygen Logger Operation Manual

D-OptoLogger Dissolved Oxygen Logger Operation Manual D-OptoLogger Dissolved Oxygen Logger Operation Manual Software version 3.4 Contents 1. Introduction..... 1 Optical Sensor Technology.....1 Features...... 1 2. D-OptoLogger Specifications.2 Specifications...

More information

SHIMADZU LC-10/20 PUMP

SHIMADZU LC-10/20 PUMP SHIMADZU LC-10/20 PUMP Clarity Control Module ENG Code/Rev.: M091/70C Date: 24.10.2017 Phone: +420 251 013 400 DataApex Ltd. Fax: +420 251 013 401 Petrzilkova 2583/13 clarity@dataapex.com 158 00 Prague

More information

Technology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer.

Technology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer. NXT Main Menu My Files Files are automatically placed into the appropriate folders. When you download a program using a Sound file to the NXT, the program will be placed under Software files while the

More information

Software Manual for FITstep Pro Version 2

Software Manual for FITstep Pro Version 2 Thank you for purchasing this product from Gopher. If you are not satisfied with any Gopher purchase for any reason at any time, contact us and we will replace the product, credit your account, or refund

More information

D-Opto Dissolved Oxygen Sensor Operation Manual

D-Opto Dissolved Oxygen Sensor Operation Manual D-Opto Dissolved Oxygen Sensor Operation Manual Software version 2.6 Contents 1. Introduction..... 1 Optical Sensor Technology.... 1 Features...... 1 2. D-Opto Specifications. 2 Specifications... 2 3.

More information

Technology. Using Bluetooth

Technology. Using Bluetooth Bluetooth is a communication technology that makes it possible to send and receive data without using wires. Using the Bluetooth features, you can set up a wireless connection between your NXT and other

More information

Steltronic StelPad User Guide

Steltronic StelPad User Guide StelPad User Guide Steltronic StelPad User Guide Contents Contents... 1 About StelPad and its Features... 3 StelPad System Elements... 3 StelPad Computer Integration with Focus... 4 Enable Custom Graphic

More information

Perfect Golf Quick Start Guide

Perfect Golf Quick Start Guide Quick Start Guide Perfect Golf Quick Start Guide To play Perfect Golf you must first have purchased the following: 1. A SkyTrak Launch Monitor 2. Have an active Play and Improve Package 3. Have purchased

More information

PC Configuration software for Discovery MkVI v 1.03 User guide

PC Configuration software for Discovery MkVI v 1.03 User guide PC Configuration software for Discovery MkVI v 1.03 User guide This user guide describes the different features included in PC Config software, version 1.03, and how they are used. When referring to this

More information

AMS 6915 Board mount pressure sensor with digital output (I²C)

AMS 6915 Board mount pressure sensor with digital output (I²C) Board mount pressure sensor with digital output (I²C) FEATURES Calibrated and temperature compensated pressure sensor with digital output (I²C) Differential, relative (gage), bidirectional differential,

More information

MIDI Lighted Rocker Tab Installation Manual

MIDI Lighted Rocker Tab Installation Manual MIDI Lighted Rocker Tab Installation Manual 00-0- MLRT- LRT-A LIMITED WARRANTY Classic Organ Works warrants the MDKC and LRT-A to be free from defects in materials and workmanship under normal use for

More information

Figure SM1: Front panel of the multipatcher software graphic user interface (GUI) at the beginning of multipatcher operation.

Figure SM1: Front panel of the multipatcher software graphic user interface (GUI) at the beginning of multipatcher operation. APPENDIX 2. Multipatcher Software Setup and Operation. The multipatcher program is organized into four panels. There are controls that allow the user to specify various parameters into the system. The

More information

DIVE MEET SCORING INSTRUCTIONS. Day before meet

DIVE MEET SCORING INSTRUCTIONS. Day before meet DIVE MEET SCORING INSTRUCTIONS Day before meet Physical set up Set up registration/scoring table #1 on 1 meter side and scoring table #2 on 3 meter side of diving well, judges chairs, and award stand as

More information

HyperSecureLink V6.0x User Guide

HyperSecureLink V6.0x User Guide HyperSecureLink V6.0x User Guide Note: This software works with the LS-30 Version (06.0x or later) 1, Hardware Installation: 1-1, Connection Diagram for USB or RS-232 Computer Interface To LS-30 CM1 To

More information

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408) RACEAMERICA T i m i n g S y s t e m s Demo Tree Controller Owner s Manual Models 3204D, 3204DW & 3204DX Rev D RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA 95055-3469 (408) 988-6188 http://www.raceamerica.com

More information

STAND alone & p.c. VERSION

STAND alone & p.c. VERSION STAND alone & p.c. VERSION ECONOMY TRACK SYSTEMS 1/4 & 1/8 Mile Asphalt Track Dirt / Sand Track Mud Track Snowmobile Track R/C Car Track Custom Track Systems Timing to.001 Accuracy Time Slip Printer Optional

More information

Using the Lego NXT with Labview.

Using the Lego NXT with Labview. Using the Lego NXT with Labview http://www.legoengineering.com/component/content/article/105 The Lego NXT 32-bit ARM microcontroller - an Atmel AT91SAM7S256. Flash memory/file system (256 kb), RAM (64

More information

Setting up the Ingenico isc250 Pinpad via USB in Windows 8

Setting up the Ingenico isc250 Pinpad via USB in Windows 8 One Blue Hill Plaza, 16 th Floor, PO Box 1546 Pearl River, NY 10965 1-800-PC-AMERICA, 1-800-722-6374 (Voice) 845-920-0800 (Fax) 845-920-0880 Setting up the Ingenico isc250 Pinpad via USB in Windows 8 The

More information

Previous Release Notes

Previous Release Notes Release Notes Shearwater Desktop 3.1.5 Support for NERD 2. Previous Release Notes Version 3.1.4 Improved Bluetooth Reliability with the initial connection. Bug Notes: dded software workaround to allow

More information

Track and Field Interface

Track and Field Interface Track and Field Interface Quick Guide ED-14511 Rev 4 5 June 2007 ED-14511 P-1173 Rev 4 5 June 2007 Please fill in the information below for your display; use it for reference when calling Daktronics for

More information

The ICC Duckworth-Lewis Calculator. Professional Edition 2008

The ICC Duckworth-Lewis Calculator. Professional Edition 2008 The ICC Duckworth-Lewis Calculator Professional Edition 2008 (Version 1.1) Installation and operating instructions Any queries about operating the program should be sent to steven.stern@anu.edu.au 2008

More information

AUTOMATIC GAS MANIFOLDS

AUTOMATIC GAS MANIFOLDS AUTOMATIC GAS MANIFOLDS Phoenix Pipeline Products Limited. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com

More information

AX5000 Operational Manual

AX5000 Operational Manual MIYACHI AMERICA CORPORATION The World Leader in Hermetic Sealing Systems AX5000 Operational Manual 0 Document #107-00092-001 Dec, 2013 AX5000 Operational Manual Miyachi America Corporation 1820 S. Myrtle

More information

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11 ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11 The Portatree Eliminator Super 2000 Competition Track Timer can be used with an IBM Compatible Personal Computer connected through Com Port

More information

Domino DUEMMEGI. Domino. Communication Interface DFTS User s Manual. Release September 2007

Domino DUEMMEGI. Domino. Communication Interface DFTS User s Manual. Release September 2007 Domino Domino Communication Interface DFTS User s Manual Release 2.3 - September 2007 srl Via Longhena 4-20139 MILANO Tel. 02/57300377 - FAX 02/55213686 Domino - DFTS: User s Manual R.2.3 Index 1- INTRODUCTION...3

More information

The ICC Duckworth-Lewis-Stern calculator. DLS Edition 2016

The ICC Duckworth-Lewis-Stern calculator. DLS Edition 2016 The ICC Duckworth-Lewis-Stern calculator DLS Edition 2016 (DLS2-2016) Installation and operating instructions Queries about program operation should be sent to: Steven.Stern@qut.edu.au 2016 International

More information

Technology. Using Bluetooth

Technology. Using Bluetooth Bluetooth is a communication technology that makes it possible to send and receive data without using wires. Using the Bluetooth features, you can set up a wireless connection between your NXT and other

More information

PRODUCT MANUAL. Diver-Mobile for Android

PRODUCT MANUAL. Diver-Mobile for Android PRODUCT MANUAL Diver-Mobile for Android Contact details: Van Essen Instruments B.V. Van Essen Instruments - Canada Delftechpark 20 630 Riverbend Drive, Suite 100 2628 XH Delft Kitchener, ON, The Netherlands

More information

Version 3.1.0: New Features/Improvements: Improved Bluetooth connection on Windows 10

Version 3.1.0: New Features/Improvements: Improved Bluetooth connection on Windows 10 Version 3.1.0: Improved Bluetooth connection on Windows 10 ***Important notice for Mac Users: Upgrading from Shearwater Desktop 3.0.8 to 3.1.0 will not cause issues. Upgrading from any 2.X.X to any 3.X.X

More information

Digi Connect ME 9210 Linux: 2 nd serial over FIM

Digi Connect ME 9210 Linux: 2 nd serial over FIM Digi Connect ME 9210 Linux: 2 nd serial over FIM Document History Date Version Change Description 09/04/2009 Initial entry/outline Table of Contents Document History... 2 Table of Contents... 2 1 Problem

More information

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com Operating Manual Software for Fire and Gas Warning Units Order No.: 10154656/01 MSAsafety.com MSA Europe GmbH Schlüsselstrasse 12 8645 Rapperswil-Jona Switzerland info.ch@msasafety.com www.msasafety.com

More information

SWIM MEET MANAGER 5.0 NEW FEATURES

SWIM MEET MANAGER 5.0 NEW FEATURES SWIM MEET MANAGER 5.0 NEW FEATURES Updated January 24, 2014 1 ABOUT SWIMMING MEET MANAGER 5.0 MEET MANAGER 5.0 for ming (SWMM) is HY-TEK's 6th generation of Meet Management software. Provides the very

More information

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012 JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012 UNIVERSITY OF TEXAS AT ARLINGTON Nanofabrication Research and Teaching Facility TABLE OF CONTENTS 1. Introduction....2 1.1 Scope of Work.....2

More information

AMS 2710 PCB pressure sensor module with V output

AMS 2710 PCB pressure sensor module with V output FEATURES Universal pressure sensor module with 0.. 10 V voltage output Fully calibrated and temperature compensated sensor module Variants for (bidirectional) differential, gage, absolute and barometric

More information

Diver-Pocket Diver-Pocket Premium

Diver-Pocket Diver-Pocket Premium User s Manual Diver-Pocket Diver-Pocket Premium Copyright Information 2011 Schlumberger Water Services. All rights reserved. No portion of the contents of this publication may be reproduced or transmitted

More information

01 TM SuperModified Testing with RS485 <> USB

01 TM SuperModified Testing with RS485 <> USB Testing with RS485 USB 1. Preinstalled cables The Supermodified controller comes with several wires soldered. By default the power and RS485 cables are soldered. I2C and legacy RC servo interface cables

More information

Setting Up the Ingenico isc250 Pinpad via USB

Setting Up the Ingenico isc250 Pinpad via USB One Blue Hill Plaza, 16 th Floor, PO Box 1546 Pearl River, NY 10965 1-800-PC-AMERICA, 1-800-722-6374 (Voice) 845-920-0800 (Fax) 845-920-0880 Setting Up the Ingenico isc250 Pinpad via USB The following

More information

XC2 Client/Server Installation & Configuration

XC2 Client/Server Installation & Configuration XC2 Client/Server Installation & Configuration File downloads Server Installation Backup Configuration Services Client Installation Backup Recovery Troubleshooting Aug 12 2014 XC2 Software, LLC Page 1

More information

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA Software version 2.6 Table of contents 1 Introduction...3 1.1 Optical Sensor Technology...3 1.2 Installation...4 1.3 Operation...5

More information

The Complete 100 Day Dash Guide Updated May 7, 2013

The Complete 100 Day Dash Guide Updated May 7, 2013 The Complete 100 Day Dash Guide Updated May 7, 2013 This guide covers the following topics (click the links to read more): Official Rules Frequently Asked Questions (FAQs) How to Register for the Dash

More information

User manual CF8-D/W-IN

User manual CF8-D/W-IN User manual CF8-D/W-IN General The sensor CF8-D/W-IN is used to measure the carbon dioxide concentration inside incubators. All functions can be modified from a PC with the communication cable. UMA 48

More information

RM-80 respiration monitor

RM-80 respiration monitor RM-80 respiration monitor User Manual September 18, 2015 0025-003M 950 North Hague Avenue Columbus, Ohio 43204-2121 USA Sales: sales@colinst.com Service: service@colinst.com Phone: (614) 276-0861 Fax:

More information

NEULOG OXYGEN LOGGER SENSOR GUIDE

NEULOG OXYGEN LOGGER SENSOR GUIDE NeuLog oxygen logger sensor NUL-205 The oxygen sensor can be used for any science experiment or activity where oxygen levels, dissolved or gaseous, are required. Some fields of study include Chemistry,

More information

Mac Software Manual for FITstep Pro Version 2

Mac Software Manual for FITstep Pro Version 2 Thank you for purchasing this product from Gopher. If you are not satisfied with any Gopher purchase for any reason at any time, contact us and we will replace the product, credit your account, or refund

More information

Connections The C20B can be connected either using the Molex locking socket, or by connection to four plated through holes. The plated through

Connections The C20B can be connected either using the Molex locking socket, or by connection to four plated through holes. The plated through E-MAIL: C20 Carbon Dioxide Sensor General Description The C20B is a carbon dioxide designed specifically for educational applications. The C20B provides fully temperature compensated readings of Carbon

More information

Datasheet: K-30 ASCII Sensor

Datasheet: K-30 ASCII Sensor Datasheet: K-30 ASCII Sensor The K30 ASCII sensor is a low cost, infrared and maintenance free transmitter module intended to be built into different host devices that require CO2 monitoring data. The

More information

Figure 2. Auxiliary table

Figure 2. Auxiliary table Voyage Recorder is an affordable, miniature black box for a yacht. A Digital Voyage data recorder (VDR) connected to the NMEA 2000 network on your boat serves to record and store boat data. It collects

More information

GV Standard X-Vent. Setup, Commissioning & Installation Guide

GV Standard X-Vent. Setup, Commissioning & Installation Guide GV Standard X-Vent Setup, Commissioning & Installation Guide Technical experts in the design, manufacture and supply of precision engineered, architectural rooflights for residential and commercial buildings.

More information

uemis CONNECT: Synchronisation of the SDA with myuemis

uemis CONNECT: Synchronisation of the SDA with myuemis uemis CONNECT: Synchronisation of the SDA with myuemis 1 What is myuemis? In myuemis, your private area on the Internet portal www.uemis.com, you can visualise your dives, manage your database and transfer

More information

J12 TICKET DISPENSER HOPPER ALL STOP STOP 1 STOP 2 STOP 3 BIG DOUBLE SMALL TAKE PLAY START CURRENT PRODUCTION BOARD TYPE

J12 TICKET DISPENSER HOPPER ALL STOP STOP 1 STOP 2 STOP 3 BIG DOUBLE SMALL TAKE PLAY START CURRENT PRODUCTION BOARD TYPE New Cherry 96 /Fruit Bonus 96 (Special Edition) NEW CHERRY 96 NEW FRUIT BONUS 96 NEW CHERRY 96 SPECIAL EDITION NEW FRUIT BONUS 96 SPECIAL EDITION PARTS SIDE SOLDER SIDE 1 VIDEO RED VIDEO GREEN 1 2 VIDEO

More information

Club s Homepage Use this feature to return the club s website.

Club s Homepage Use this feature to return the club s website. The first time the golfer logs into the Internet Golf Reservation System, the member # is the club assigned golfer number, the default password is 1234. The golfer will automatically be transferred to

More information

Integrate Riverbed SteelHead. EventTracker v8.x and above

Integrate Riverbed SteelHead. EventTracker v8.x and above EventTracker v8.x and above Publication Date: March 27, 2018 Abstract This guide provides instructions to configure a Riverbed SteelHead to send its syslog to EventTracker Enterprise Scope The configurations

More information

The easy, economical solution for Making wide-format Industrial Labels and Heat Shrink Tube Identification

The easy, economical solution for Making wide-format Industrial Labels and Heat Shrink Tube Identification The easy, economical solution for Making wide-format Industrial Labels and Heat Shrink Tube Identification K-Sun Corporation 1-800-622-6312 (x. 210) FAX 1-800-522-9108 www.ksun.com info@ksun.com 370 SMC

More information

FRDS GEN II SIMULATOR WORKBOOK

FRDS GEN II SIMULATOR WORKBOOK FRDS GEN II SIMULATOR WORKBOOK Trotter Control Inc 2015 Document# Revision Revised 9001-0038 FRDS GEN II Simulator Workbook E 02/15/2015 by DC FRDS GEN II Simulator Workbook This workbook is a follow-on

More information

AUTO PUMP STATUS CENTER

AUTO PUMP STATUS CENTER INSTRUCTION MANUAL AUTO PUMP STATUS CENTER PRESSURE ONLY MODEL #: 091-198-12-AP File: IM_091-198-12-AP_revD.indd Rev: D, pg 3 WD Revised By: PSS Date: 2-01-2016 3 YEAR WARRANTY INTRODUCTION The Auto Pump

More information

S-CURVE DOCUMENTATION AND TUTORIAL FOR THE S-CURVE ON THE COOL MUSCLE

S-CURVE DOCUMENTATION AND TUTORIAL FOR THE S-CURVE ON THE COOL MUSCLE S-CURVE DOCUMENTATION AND TUTORIAL FOR THE S-CURVE ON THE COOL MUSCLE 1. INTRODUCTION The s-curve function allows the user to define a smooth response yet still maintain a high acceleration. In many applications

More information

Quick Start Guide. For Gold and Silver Editions

Quick Start Guide. For Gold and Silver Editions Quick Start Guide For Gold and Silver Editions Table of Content Introduction... 3 Prerequisites... 3 Installation and Setup... 4 Download and Install QQEvolution 2... 4 Create Users... 8 Create Agent/CSR/Producer...

More information

SQL LiteSpeed 3.0 Installation Guide

SQL LiteSpeed 3.0 Installation Guide SQL LiteSpeed 3.0 Installation Guide Revised January 27, 2004 Written by: Jeremy Kadlec Edgewood Solutions www.edgewoodsolutions.com 888.788.2444 2 Introduction This guide outlines the SQL LiteSpeed 3.0

More information

Q2: Which instruments are necessary for monitoring the groundwater level?

Q2: Which instruments are necessary for monitoring the groundwater level? Micro-Diver 1. Q: What do Divers actually do? 2. Q: Which instruments are necessary for monitoring the groundwater level? 3. Q: Can I place the Diver close to an electrical pump? 4. Q: How should I install

More information

Wickets Administrator

Wickets Administrator Wickets Administrator Software For Managing Stored Value Wickets 01/08/2008 Product Details And Operating Instructions Overview This page describes each major function of Wickets Administrator in detail.

More information

1001ICT Introduction To Programming Lecture Notes

1001ICT Introduction To Programming Lecture Notes 1001ICT Introduction To Programming Lecture Notes School of Information and Communication Technology Griffith University Semester 2, 2015 1 4 Lego Mindstorms 4.1 Robotics? Any programming course will set

More information

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc. The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is

More information

DIY - PC - Interface for Suunto Cobra/Vyper/Mosquito

DIY - PC - Interface for Suunto Cobra/Vyper/Mosquito DIY - PC - Interface for Suunto Cobra/Vyper/Mosquito Summary This document is the distinct consequence of the Spyder/Stinger interface DIY. After having many e-mails concerning the application for the

More information

Microfluidic Demonstration

Microfluidic Demonstration Microfluidic Demonstration Co-flow of liquids across a microfluidic chip Create a microfluidic controller to flow liquids across a microfluidic chip. 1. Assemble fluidic circuits and attach to breadboard.

More information

CONSUMER MODEL INSTALLATION GUIDE

CONSUMER MODEL INSTALLATION GUIDE CONSUMER MODEL INSTALLATION GUIDE System requirements Windows System Requirements To use your TOMI and its software, your system should have: A Microsoft Windows compatible PC with a Pentium IV processor

More information

Introducing Version 7R2

Introducing Version 7R2 Introducing Version 7R2 CircuitCAM - A Tutorial Manufacturing OperationsSoftware [Type text] COPYRIGHTS AND TRADEMARKS Information in this document is subject to change without notice. Copyright 2009 Aegis

More information

Armfield Distillation Column Operation Guidelines

Armfield Distillation Column Operation Guidelines Armfield Distillation Column Operation Guidelines 11-2016 R.Cox Safety SAFETY GLASSES ARE REQUIRED WHEN OPERATING THE DISTILLATION COLUMN Wear gloves when mixing alcohol feedstock The column will become

More information

Digi Connect ME 9210 Linux: serial port 2 for JTAG modules

Digi Connect ME 9210 Linux: serial port 2 for JTAG modules Digi Connect ME 9210 Linux: serial port 2 for JTAG modules Document History Date Version Change Description 08/05/2009 Initial entry/outline Table of Contents Document History... 2 Table of Contents...

More information

REMOTE CLIENT MANAGER HELP VERSION 1.0.2

REMOTE CLIENT MANAGER HELP VERSION 1.0.2 VERSION 1.0.2 MERCHANT SALES: 800-637-8268 New Merchant Accounts PARTNER PROGRAMS: 800-637-8268 New and existing partnerships CUSTOMER CARE: 800-338-6614 Existing merchant account support Statements and

More information

RPS900W Redundant Power Supply. Installation Guide.

RPS900W Redundant Power Supply. Installation Guide. RPS900W Redundant Power Supply Installation Guide www.edge-core.com Installation Guide RPS900W Redundant Power Supply Single DC Output Port with Dual Output Voltages RPS900W E10013-CS-R01 1500000081A

More information

Page 2 of 46 Prepared by: Engr. Ram Sankar

Page 2 of 46 Prepared by: Engr. Ram Sankar Page 2 of 46 CHAPTER 1 GETTING STARTED Page 3 of 46 Establishing Communication with Relay: 1. Open MICOM S1 studio and click on NEW SYSTEM. 2. Name it and save on desired location and click on OK. Page

More information

Quick Guide. SGX-CA500 Cycle Computer SGY-PM Series Power Meters

Quick Guide. SGX-CA500 Cycle Computer SGY-PM Series Power Meters Quick Guide SGX-CA500 Cycle Computer SGY-PM Series Power Meters Easy Installation and Advanced Functionality Fast Facts: Pioneer Power Meter Cranksets and arms ship pre-set in the ANT+ Format Simply install

More information

OPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051

OPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051 NOT SCALE / IF IN DOUBT ASK* DIVE CALIPER OPERATION MANUAL *THIS INFORMATION IS THE PROPERTY OF ZEBRA-TECH LTD. ALL RIGHTS RESERVED.* *ALL UNITS IN MM/DEGREES UNLESS SPECIF SURFACE F 3.2 Ra UNLESS S Part

More information

Read this first. Zetasizer nano series Self installation and Quick start guide MRK825-02

Read this first. Zetasizer nano series Self installation and Quick start guide MRK825-02 ! Read this first Zetasizer nano series Self installation and Quick start guide I N S T R U M E N T S MRK825-02 Zetasizer Nano series Self installation and Quick start guide MAN0383 Issue 1.1 July 2007

More information

YSC-8330 USER MANUAL XI AN TYPICAL INDUSTRIES CO.,LTD.

YSC-8330 USER MANUAL XI AN TYPICAL INDUSTRIES CO.,LTD. YSC-8330 USER MANUAL XI AN TYPICAL INDUSTRIES CO.,LTD. Contents 1 Notice 1.1 Work environment 1.2 Notice of installation 1.3 Notice of safety 2 Installation and Adjustment 2.1 Controll box 2.2 Speed controller

More information

KEM Scientific, Inc. Instruments for Science from Scientists

KEM Scientific, Inc. Instruments for Science from Scientists KEM Scientific, Inc. Instruments for Science from Scientists J-KEM Scientific, Inc. 6970 Olive Blvd. St. Louis, MO 63130 (314) 863-5536 Fax (314) 863-6070 E-Mail: jkem911@jkem.com Precision Vacuum Controller,

More information

CF8-W-Disp-CO. User manual. CO 2 / CO sensor with built-in general purpose controller

CF8-W-Disp-CO. User manual. CO 2 / CO sensor with built-in general purpose controller User manual CF8-W-Disp-CO CO 2 / CO sensor with built-in general purpose controller General The IAQ-sensor product CF8-W-Disp-CO is used to measure indoor air carbon dioxide and carbon monoxide concentrations.

More information

OMNISPORT 2000 SWIMMING QUICK REFERENCE

OMNISPORT 2000 SWIMMING QUICK REFERENCE Before During After OMNISPORT 2000 SWIMMING QUICK REFERENCE 1. Confirm that the timer is reset. 2. Set the timer to the correct event and heat. The right LCD, line 2 displays E:(event) H:(heat) R:(round)

More information

SECTION 2 SMART PAYOUT MANUAL SET FIELD SERVICE MANUAL

SECTION 2 SMART PAYOUT MANUAL SET FIELD SERVICE MANUAL SECTION 2 SMART PAYOUT MANUAL SET FIELD SERVICE MANUAL Innovative Technology assume no responsibility for errors, omissions, or damages resulting from the use of information contained within this manual.

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication

More information

OC508 Programmable mv Calibrator

OC508 Programmable mv Calibrator OC508_GBM_201609 OC508 Programmable mv Calibrator Owner s Manual Orbit Controls AG Zürcherstrasse 137 CH8952 Schlieren - ZH orbitcontrols.ch OC508 Programmable mv Calibrator Selection of DIN Thermocouples

More information

D-Opto. Dissolved Oxygen Sensor. Operation Manual (Software Version 1.0)

D-Opto. Dissolved Oxygen Sensor. Operation Manual (Software Version 1.0) D-Opto Dissolved Oxygen Sensor Operation Manual (Software Version 1.0) Table of contents 1 Introduction...3 1.1 Optical Sensor Technology...3 2 Software...4 2.1 Installation...4 2.2 Operation...4 3 Operation...9

More information

Fencing Time Version 4.3

Fencing Time Version 4.3 Fencing Time Version 4.3 Upgrading your Fencing Time Server October 2017 Copyright 2017 by Fencing Time, LLC. All rights reserved. Overview Periodically, a new version of Fencing Time is released. In most

More information

Quick Start Guide. A. Hardware installation B. Software installation C. Start the software for the first time D. Do your first measurement

Quick Start Guide. A. Hardware installation B. Software installation C. Start the software for the first time D. Do your first measurement Quick Start Guide This Quick Start Guide describes the hardware and software installation process and the Measurement feature in a simple way. Please follow the sequence of the steps to avoid problems

More information

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION 1 INFORMATION and TECNICAL DESCRIPTION 14 2 AIRLEADER Professional Compressor Management + Compressed Air Visualisation + Alarm Service Management + AIRLEADER - has been the effective answer for compressed

More information

For running only the scoresheet application without any video features only some very basic hardware / software requirements have to be fulfilled:

For running only the scoresheet application without any video features only some very basic hardware / software requirements have to be fulfilled: Digital Scoresheet user manual Requirements For running only the scoresheet application without any video features only some very basic hardware / software requirements have to be fulfilled: Laptop, preferably

More information

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure PPMS Service Note 1099-412 In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure Introduction: Loss of electricity to the PPMS EverCool II should not cause damage to

More information

OWNER S MANUAL. GLF-125 Golf GPS. The Whistler Group, Inc. - Corporate Offices 3604 NW Frontage Road Bentonville, AR

OWNER S MANUAL. GLF-125 Golf GPS. The Whistler Group, Inc. - Corporate Offices 3604 NW Frontage Road Bentonville, AR The Whistler Group, Inc. - Corporate Offices 3604 NW Frontage Road Bentonville, AR 72712 1-800-531-0004 OWNER S MANUAL GLF-125 Golf GPS The Whistler Group, Inc. - Customer Return Center 551 North 13th

More information