1 AEi Systems is an electrical engineering services company, with a primary focus on providing Worst Case Circuit Analysis. Other analysis services we provide include Electrical SDRLs such as FMECA, MTBF, Stress & Derating analysis, as well as, Hardware Failure Resolution, Trouble-shooting, and Component and Circuit Test and Characterization. We also are experts in SPICE Modeling and make, or have made the majority of Power IC models for Linear Technology, National s Webench, Texas Instruments, ON Semiconductor, Analog Devices, as well as many others. We know that the Worst Case scenario can happen when you least expect it. As a result, we end up reviewing a lot of the WCCA performed by other companies to make sure it is up to industry standards. Our desire to see the level of analysis improved across the aerospace industry has motivated us to write this paper. Shown above are some WC examples. At the top right is a picture of the Large Hadron Collider at CERN. AEi Systems analyzed and fixed the power supply for the Atlas Experiment and then designed a new supply for the challenging environment (300Gauss Magnetic field, High TID and Neutron Radiation). AEi Systems, LLC 1

2 Is worst case analysis a thought process?? We re often asked Why do you guys always take such a pessimistic view of everything? Our response is Why do engineers find this process so uncomfortable? No one likes to be told their baby is ugly. But the objective of WCCA is to look for potential issues in an effort to improve product quality and reliability with the added bonus of saving the current program money while making future products more robust. In 17 years, we have not analyzed a design that has passed a WCCA with 100% compliance. On the other hand, every WCCA has resulted in an superior end product and a good deal of time and money saved. AEi Systems, LLC 2

3 AEi Systems reviews a lot of worst case analysis. So we thought we d hit some key points related to the issues and problems we ve encountered. This presentation looks at two aspects; Lessons Learned from HOW we do WCCA and Lessons Learned from actually DOING WCCA. On AEi Systems web site there is a white paper on WHY you might want to do a WCCA. In addition, Aerospace Corporation has put out a TOR guideline which covers similar territory, as well as some details on what to analyze for different types of circuits. AEi Systems, LLC 3

4 Analyses that we review from all types of companies, from prime contractors to their smallest subcontractors, suffer from the same issue LACK OF RIGOROUSNESS. Two factors are clearly evident; insufficient analyses and insufficient detail in the analyses that are performed. The selection of the parameters to be analyzed should NOT be generated by the circuit designer. Mistakes in the design will often be repeated in the analysis. Circuits that the designer believes are too simple, obvious, or heritage may be ignored. This is often where problems lie. In fact, we often look for which analyses were NOT presented in order to determine where to look for design problems. Finally, is the documentation complete. Each analysis must be explained in a comprehensive and organized fashion complete with the functional description, methodology of analysis, detailed assumptions, model correlation, analysis results and conclusions such that it can be easily reviewed and referred to later in the product s life cycle. AEi Systems, LLC 4

5 Companies should not do their own WCCA. If they do, it should be done by an independent group. Independence puts checks and balances into the analysis. The project engineer is often under great schedule pressure, the program budget pressure and the company political pressure. When was the last time you walked into your boss s office and said, wow, look how I can bring my circuit to its knees. Thinking worst case is not normal for most engineers. WCCA is the last line of defense for assessing whether the design will perform properly throughout its lifetime. Its just too important. There are just too many biases and we should not let our egos or budgets rule this critical analysis. The worst situation is when a WCCA is bid before the circuitry is defined and/or there is schedule pressure. Both will lead to inadequate and often erroneous results. A WCCA should be bid by someone that both knows the details of the circuitry that will be built AND has performed a WCCA in the past. The availability, or lack thereof, of test data, accurate models, tolerance information, radiation data, and the scope of the analyses that should be performed, all factor into the cost and time needed to properly perform a WCCA. The selection of personnel is also a factor. Its one thing to have a junior engineer working along side a seasoned veteran, but its not enough to simply have the review done by senior engineers. It must be performed by experienced personnel. If they are not available, you need to call AEi Systems because we have the experience and the resources. AEi Systems, LLC 5

6 An engineer from a prime satellite manufacturer once told us that correlating and verifying models from a vendor should be the exception not the rule and that its ok to assume that vendor models are accurate. WHAT A DISASTER! With a little bit of investigation its clear that the exact opposite is true. There are two aspects to verify with EVERY SPICE model; does the model emulate the particular characteristic that the analysis requires and second, how accurately is the characteristic emulated over the operating range that the model will see in the simulation. AEi Systems, LLC 6

7 The models available from IC vendors, or in your SPICE package, are generally NOT tested against hardware. Most are made from data sheet information. Data sheets are not technical documents, they are marketing tools. Much of the data is misleading and from conflicting operating conditions, making model generation from a coherent set of data that covers the entire operating range of the part difficult if not impossible. Without correlating your own models you don t know what level of accuracy and fidelity you have. Recently, we tested a linear regulator model from an IC vendor for output impedance. We also tested the real part. The data was not in the data sheet. The results didn t match. Without the right output impedance, what characteristics are not correct? Stability, step load, ripple rejection; not much right? You must test and validate every single model you use for every characteristic that has to be right. AEi Systems, LLC 7

8 Yes, its true. With SPICE its garbage in, garbage out. But with high quality/high fidelity models in, the results can be dead on accurate. In this simulation of the power bus in the Space Station, AEi predicted, two years ahead of time, that a master computer reset would be triggered via a bus dropout every time the spacecraft went through an eclipse. Sure enough, as the picture on the right shows, that s just what preliminary circuitry did. Using the accurate model, AEi was able to confirm a fix for the circuit error. Investment in your models is required to built up a library that you have confidence in. The investment is well worth it and will save you time and schedule on the next program. Accurate WCCA relies to a large degree on accurate SPICE models and modeling capabilities, and AEi Systems is the number one source in the world in terms of custom SPICE modeling. AEi Systems has proprietary agreements and relationships with all the key component manufacturers, including TI, Linear Technology, Analog Devices, Microsemi, Intersil and National Semiconductor. That means that AEi Systems has or is able to obtain proprietary information that is not easily available to others. This information is critical to getting key performance assumptions correct and enables AEi to perform WCCA faster than other resources. AEi Systems, LLC 8

9 In order to perform a WCCA you need to be able to get reliable test data. Correlation of early hardware to test data is essential for model correlation and a successful WCCA. This takes a great deal of skill AND experience, as well as the right test equipment. We often find inadequate test equipment (insufficient bandwidth) and poor interconnects and probes at the heart of bad data. In this case, the circuit designer didn t test their regulator with sufficient bandwidth (left). AEi s model revealed a problem with the output impedance and ESR (in the nominal case). Further testing confirmed the finding. AEi worked interactively with the product manufacturer and customer to assess the impact of the poor stability and implement a fix. AEi Systems, LLC 9

10 Correct computation of EOL tolerances and good models are not the only hurdles to using SPICE. Applying the tolerances can be tricky. One mistake and your simulation results will be incorrect. It takes experience and a deep knowledge of SPICE parameters to get this right. The first thing to check is that your models behave correctly over the entire range of tolerances. Are the tolerances you applied correlated or uncorrelated. Does the SPICE simulator you use truncate the distribution? Datasheet parameters rarely correspond to a specific SPICE parameter, especially in subcircuit macro-models. Take this simple example of the forward voltage tolerance on a diode; its not as straightforward as it seems. How do you get the model to give you the right Vf min-max variation during a Monte Carlo analysis given there isn t a VF SPICE parameter (diodes use two parameters, IS and N to define the forward voltage)? You can t just apply the EVA tolerance on the N and/or IS parameters. The knowledge of how to accurately apply tolerances to SPICE models can only be obtained over years of experience in doing WCCA something that AEi Systems brings to the table. AEi Systems, LLC 10

11 Most analysts perform Monte Carlo analysis incorrectly. They mistakenly believe that you can simply chose an arbitrary number of runs and use the worst simulation results (end-points) as the worst case performance. This should scare those of you that do this as you have been making design decisions based on an erroneous assumption. Monte Carlo results must be embedded in a valid statistical framework (normally a confidence interval plus probability/population coverage). Without one you are not assessing the results correctly. You basically don t know what you have as a result. AEi Systems uses two proven methods; Tolerance Intervals for Normal Distribution and Distribution Free Tolerance Intervals (next slide); the only correct way to determine the number of runs such that you can use the simulation family s end-points. AEi Systems, LLC 11

12 The Distribution Free Tolerance Interval method provides a basis for the selection of the number of runs necessary for the simulation end-points to be used as the worst case result given a specific confidence interval and population coverage. AEi Systems, LLC 12

13 People often find reasons to not perform a WCCA that don t quite make sense when you think about them. AEi Systems, LLC 13

14 A large commercial space hardware manufacturer once told us that they only do Stress & Derating analysis, not WCCA. I told them that is a part based analysis, stress doesn t check circuit functionality. They countered with the fact that their missions were short. When asked whether that short mission life made it any less important that their product perform successfully they countered with the argument that heritage, testing and budgetary constraints prohibited WCCA. They didn t seem to understand that the only way to know, even over BOL tolerances, if a circuit is going to function properly is WCCA. They also didn t understand that compared to additional testing beyond specification required parameters WCCA can REDUCE costs. There is a reason a majority of the WCCA performed is based on derived requirements, many of which can not easily be tested. Simply put, you can t verify performance with test alone and most mission anomalies are due to flaws in the design. They also didn t understand that WCCA provides benefits beyond the analysis, improving future product generations and lowering insurance costs. AEi Systems, LLC 14

15 Many of the problems we see during the course of analysis are in the simplest circuits, which are often given little attention. These also tend to be the most critical circuits. Some of the most common analysis findings are shown above. In addition to EOL issues, WCCA is extremely valuable during the initial stages; when we correlate the nominal models and BOL tolerances with unit test data. This is where product quality and confirmation of circuit fixes occur. AEi Systems, LLC 15

16 While there are many lessons to be learned from WCCA, one of the biggest is loop stability. The popular multi-winding Flyback power supply, with its outputs post regulated, is a common configuration for power generation in satellites. While often used, its complexities are frequently misunderstood and underestimated. This topology is one of the hardest to analyze for EOL performance due to the complexity of the power transformer. The actual flight configuration magnetic must be measured in order for a model to be derived. Without the data you can not make a valid model and will, therefore, not get most of the analysis (stability, cross-regulation, CS, step load, etc.) of your power supply correct. Prediction of leakage tolerances is even less understood. An example of AEi s power transformer modeling technique can be found on the AEi website in the paper AEi Systems Component Test and Model Summary. AEi Systems, LLC 16

17 While most WCCA guidelines documents specify only a phase/gain margin stability assessment, it is possible that such an assessment does not actually quantify the stability of the power supply or regulator under investigation. In the picture (left) we see the phase margin as 50 degrees. But the step load response has a Q of 4 or 5, clearly not corresponding to 50 degrees. The stability of this power supply would not be properly assessed if only left up to the phase/gain margin compliance. AEi Systems has developed special test equipment to test for stability and performs testing as a service. Again, like incorrectly applying Monte Carlo methods, inexperienced users can stub their toe on one of the many pitfalls associated with testing and modeling for WCCA. AEi Systems has published a paper on this topic in the June 2012 Issue of Power Electronics Technology entitled When Bode Plots Fail Us. AEi Systems, LLC 17

18 What does poor stability mean? It can be difficult to quantify. But without an accurate assessment of every control loop, both in terms of test data and EOL performance, which can be drastically different than the typical performance, you will never know. Given capacitor tolerances, EOL performance can be over 20 to 30 degrees worse than initial/bol performance. This is why WCCA guidelines specify that ALL control loops must be assessed, even those that are not exposed outside the IC. For those, output impedance/step load testing (BOL) and simulation (EOL) are the only mechanisms available for the assessment. Performing WCCA on all your regulators is right way to go and leads to clean system power. Poor stability leads to degraded system performance. AEi Systems, LLC 18

19 Shown above are the results of a survey taken by AEi Systems. You can review and take the survey, as well as see the results at : Based on WCCA reviews we have done, based on known issues with data sheets, based on poor test data and methods, based on poor models that we know to be out there - that we have done hardware correlations on, based on incorrect Monte Carlo analysis techniques, based on who is doing the analysis, and based on this survey, its clear that the level and quality of WCCA being performed by most companies is inadequate and often used to drawn erroneous conclusions. AEi Systems, LLC 19

20 Thanks for reading through this presentation. Hopefully you ve discovered some areas for improvement in your own attempts at WCCA. Next time, you might consider letting the experts at AEi Systems handle the WCCA and other SDRLs for you. WCCA is what we do for a living and as such we can confidently say we know exactly what organizations like the Aerospace Corporation, NASA, as well as all the prime satellite manufacturers want from a WCCA. That s because we are an official SME (Subject Matter Expert) on WCCA and helped to set the guidelines as part of the MAIW 2012 (Mission Assurance Improvement Workshop) initiative. Because of our years of experience, vast library of SPICE models, and large database of tolerances, we are able to give clients a TOR compliant WCCA faster and for a lot lower cost than in-house resources. If you have any questions, please feel free to contact us at any time. AEi Systems, LLC 20

Analog Engineering Solutions

Analog Engineering Solutions Analog Engineering Solutions When your goal is mission success Worst Case Circuit Analysis (WCCA) is not an after-the-fact exercise but a cost-effective, integral part of the design process. When a WCCA

More information

3. Real-time operation and review of complex circuits, allowing the weighing of alternative design actions.

3. Real-time operation and review of complex circuits, allowing the weighing of alternative design actions. PREFERRED RELIABILITY PAGE 1 OF 5 PRACTICES VOLTAGE & TEMPERATURE MARGIN TESTING Practice: Voltage and Temperature Margin Testing (VTMT) is the practice of exceeding the expected flight limits of voltage,

More information

Spacecraft Simulation Tool. Debbie Clancy JHU/APL

Spacecraft Simulation Tool. Debbie Clancy JHU/APL FSW Workshop 2011 Using Flight Software in a Spacecraft Simulation Tool Debbie Clancy JHU/APL debbie.clancy@jhuapl.edu 443-778-7721 Agenda Overview of RBSP and FAST Technical Challenges Dropping FSW into

More information

Purpose. Scope. Process flow OPERATING PROCEDURE 07: HAZARD LOG MANAGEMENT

Purpose. Scope. Process flow OPERATING PROCEDURE 07: HAZARD LOG MANAGEMENT SYDNEY TRAINS SAFETY MANAGEMENT SYSTEM OPERATING PROCEDURE 07: HAZARD LOG MANAGEMENT Purpose Scope Process flow This operating procedure supports SMS-07-SP-3067 Manage Safety Change and establishes the

More information

Notes on Risk Analysis

Notes on Risk Analysis Notes on Risk Analysis MAXIMIZING THE CHANCES OF SUCCESS AERO 401 D. B. KANIPE MARCH, 2016 Focus of Design process Design of Spacecraft Getting the design to work as planned Accomplishing the mission objectives

More information

The IEC61508 Inspection and QA Engineer s hymn sheet

The IEC61508 Inspection and QA Engineer s hymn sheet The IEC61508 Inspection and QA Engineer s hymn sheet A few key points for those inspectors and QA engineers involved with a project using the IEC61508 group of standards by the 61508 Association SAFETY

More information

Integrating Best of Breed Outage Management Systems with Mobile Data Systems. Abstract

Integrating Best of Breed Outage Management Systems with Mobile Data Systems. Abstract Integrating Best of Breed Outage Management Systems with Mobile Data Systems Donald Shaw Partner ExtenSys Inc. 31 Plymbridge Crescent North York, ON M2P 1P4 Canada Telephone: (416) 481-1546 Fax: (416)

More information

Safety assessments for Aerodromes (Chapter 3 of the PANS-Aerodromes, 1 st ed)

Safety assessments for Aerodromes (Chapter 3 of the PANS-Aerodromes, 1 st ed) Safety assessments for Aerodromes (Chapter 3 of the PANS-Aerodromes, 1 st ed) ICAO MID Seminar on Aerodrome Operational Procedures (PANS-Aerodromes) Cairo, November 2017 Avner Shilo, Technical officer

More information

Recent changes in workplace safety regulations have heightened the awareness of hazards associated with electrical arcs.

Recent changes in workplace safety regulations have heightened the awareness of hazards associated with electrical arcs. Recent changes in workplace safety regulations have heightened the awareness of hazards associated with electrical arcs. The hazard level must be quantified and workers properly protected before entering

More information

Application Note AN-107

Application Note AN-107 SPEC Sensor TM Characterization & Calibration Considerations Scope This document is provided to describe the considerations needed to characterize, calibrate, verify and validate the measurement performance

More information

OIL & GAS. 20th APPLICATION REPORT. SOLUTIONS for FLUID MOVEMENT, MEASUREMENT & CONTAINMENT. Q&A: OPEC Responds to SHALE BOOM

OIL & GAS. 20th APPLICATION REPORT. SOLUTIONS for FLUID MOVEMENT, MEASUREMENT & CONTAINMENT. Q&A: OPEC Responds to SHALE BOOM Process VARIABILITY & Equipment RELIABILITY Are PROCESS SAFETY & CYBERSECURITY Related? Q&A: OPEC Responds to SHALE BOOM 20th 1995-2015 SOLUTIONS for FLUID MOVEMENT, MEASUREMENT & CONTAINMENT special section

More information

GUIDE TO RUNNING A BIKE SHARE. h o w t o p l a n a n d o p e r a t e a s u c c e s s f u l b i k e s h a r e p r o g r a m

GUIDE TO RUNNING A BIKE SHARE. h o w t o p l a n a n d o p e r a t e a s u c c e s s f u l b i k e s h a r e p r o g r a m GUIDE TO RUNNING A BIKE SHARE h o w t o p l a n a n d o p e r a t e a s u c c e s s f u l b i k e s h a r e p r o g r a m 20150209 The bicycle is the most loved form of transportation. No other machine

More information

Non Invasive Stability Measurements vs. Bode Plots

Non Invasive Stability Measurements vs. Bode Plots Comparisons of Non Invasive Stability Measurements vs. Bode Plots AEi Systems 5777 W. Century Blvd. Suite 285, Los Angeles, CA 945 3 26 44 info@aeng.com More Information: https://www.picotest.com/non invasive

More information

Chapter 5: Methods and Philosophy of Statistical Process Control

Chapter 5: Methods and Philosophy of Statistical Process Control Chapter 5: Methods and Philosophy of Statistical Process Control Learning Outcomes After careful study of this chapter You should be able to: Understand chance and assignable causes of variation, Explain

More information

Gravity Probe-B System Reliability Plan

Gravity Probe-B System Reliability Plan Gravity Probe-B System Reliability Plan Document #P0146 Samuel P. Pullen N. Jeremy Kasdin Gaylord Green Ben Taller Hansen Experimental Physics Labs: Gravity Probe-B Stanford University January 23, 1998

More information

POWER Quantifying Correction Curve Uncertainty Through Empirical Methods

POWER Quantifying Correction Curve Uncertainty Through Empirical Methods Proceedings of the ASME 2014 Power Conference POWER2014 July 28-31, 2014, Baltimore, Maryland, USA POWER2014-32187 Quantifying Correction Curve Uncertainty Through Empirical Methods ABSTRACT Christopher

More information

Application Notes. Aluminium Electrolytic Capacitors

Application Notes. Aluminium Electrolytic Capacitors Application Notes Aluminium Electrolytic Capacitors , now part of the Evox Rifa Group, is one of Europe s leading manufacturers of Large Can Aluminium Capacitors. The Evox Rifa Group is a major global

More information

DATA ITEM DESCRIPTION Title: Failure Modes, Effects, and Criticality Analysis Report

DATA ITEM DESCRIPTION Title: Failure Modes, Effects, and Criticality Analysis Report DATA ITEM DESCRIPTION Title: Failure Modes, Effects, and Criticality Analysis Report Number: Approval Date: 20160106 AMSC Number: N9616 Limitation: No DTIC Applicable: Yes GIDEP Applicable: Yes Defense

More information

IBIS Modeling for IO-SSO Analysis. Thunder Lay and Jack W.C. Lin IBIS Asia Summit Taipei, Taiwan Nov. 19, 2013

IBIS Modeling for IO-SSO Analysis. Thunder Lay and Jack W.C. Lin IBIS Asia Summit Taipei, Taiwan Nov. 19, 2013 IBIS Modeling for IO-SSO Analysis Thunder Lay and Jack W.C. Lin IBIS Asia Summit Taipei, Taiwan Nov. 19, 2013 Agenda What is IO-SSO? Missing Components in Traditional IO-SSO Analysis Accurate On-die and

More information

Understanding safety life cycles

Understanding safety life cycles Understanding safety life cycles IEC/EN 61508 is the basis for the specification, design, and operation of safety instrumented systems (SIS) Fast Forward: IEC/EN 61508 standards need to be implemented

More information

MIL-STD-883G METHOD

MIL-STD-883G METHOD STEADY-STATE LIFE 1. PURPOSE. The steady-state life test is performed for the purpose of demonstrating the quality or reliability of devices subjected to the specified conditions over an extended time

More information

ATION TITLE. Survey QC, Decision Making, and a Modest Proposal for Error Models. Marc Willerth, MagVAR

ATION TITLE. Survey QC, Decision Making, and a Modest Proposal for Error Models. Marc Willerth, MagVAR 1 a Modest Proposal for Error Models ATION TITLE Marc Willerth, MagVAR Speaker Information Marc Willerth VP of Survey Technologies April 11, 2018 MagVAR 2 Speaker Bio Marc Willerth Magnetic Variation Services,

More information

Software Reliability 1

Software Reliability 1 Software Reliability 1 Software Reliability What is software reliability? the probability of failure-free software operation for a specified period of time in a specified environment input sw output We

More information

Advanced Test Equipment Rentals ATEC (2832) OMS 600

Advanced Test Equipment Rentals ATEC (2832) OMS 600 Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OMS 600 Continuous partial discharge monitoring system for power generators and electrical motors Condition monitoring

More information

The IEC61508 Project Manager's & Project Engineer's hymn sheet

The IEC61508 Project Manager's & Project Engineer's hymn sheet The IEC61508 Project Manager's & Project Engineer's hymn sheet A few key points for those project managers and project engineers undertaking a project using the IEC61508 group of standards by the 61508

More information

So it s Reliable but is it Safe? - a More Balanced Approach To ATM Safety Assessment

So it s Reliable but is it Safe? - a More Balanced Approach To ATM Safety Assessment So it s Reliable but is it Safe? - a More Balanced Approach To ATM Safety Assessment ATM R&D Seminar Barcelona 2 nd to 5 th July 2007 Derek Fowler, Gilles Le Galo, Eric Perrin EUROCONTROL Stephen Thomas

More information

Every things under control High-Integrity Pressure Protection System (HIPPS)

Every things under control High-Integrity Pressure Protection System (HIPPS) Every things under control www.adico.co info@adico.co Table Of Contents 1. Introduction... 2 2. Standards... 3 3. HIPPS vs Emergency Shut Down... 4 4. Safety Requirement Specification... 4 5. Device Integrity

More information

Ch.5 Reliability System Modeling.

Ch.5 Reliability System Modeling. Certified Reliability Engineer. Ch.5 Reliability System Modeling. Industrial Engineering & Management System Research Center. - 1 - Reliability Data. [CRE Primer Ⅵ 2-6] Sources of Reliability Data. Successful

More information

Bhagwant N. Persaud* Richard A. Retting Craig Lyon* Anne T. McCartt. May *Consultant to the Insurance Institute for Highway Safety

Bhagwant N. Persaud* Richard A. Retting Craig Lyon* Anne T. McCartt. May *Consultant to the Insurance Institute for Highway Safety Review of The Impact of Red Light Cameras (Photo-Red Enforcement) on Crashes in Virginia by Nicholas J. Garber, John S. Miller, R. Elizabeth Abel, Saeed Eslambolchi, and Santhosh K. Korukonda Bhagwant

More information

Verification of Peening Intensity

Verification of Peening Intensity academic study by Dr. David Kirk Coventry University Verification of Peening Intensity INTRODUCTION Verification of peening intensity is described in SAE J443 using just the three paragraphs of section

More information

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1* Safety Manual Process pressure transmitter IPT-1* 4 20 ma/hart Process pressure transmitter IPT-1* Contents Contents 1 Functional safety 1.1 General information... 3 1.2 Planning... 4 1.3 Instrument parameter

More information

Beamex. Calibration White Paper. Weighing scale calibration - How to calibrate weighing instruments

Beamex. Calibration White Paper.  Weighing scale calibration - How to calibrate weighing instruments Beamex Calibration White Paper info@beamex.com Weighing scale calibration - How to calibrate weighing instruments Weighing scale calibration - How to calibrate weighing instruments Weighing scales, weighing

More information

New Thinking in Control Reliability

New Thinking in Control Reliability Doug Nix, A.Sc.T. Compliance InSight Consulting Inc. New Thinking in Control Reliability Or Your Next Big Headache www.machinerysafety101.com (519) 729-5704 Control Reliability Burning Questions from the

More information

THE CANDU 9 DISTRffiUTED CONTROL SYSTEM DESIGN PROCESS

THE CANDU 9 DISTRffiUTED CONTROL SYSTEM DESIGN PROCESS THE CANDU 9 DISTRffiUTED CONTROL SYSTEM DESIGN PROCESS J.E. HARBER, M.K. KATTAN Atomic Energy of Canada Limited 2251 Speakman Drive, Mississauga, Ont., L5K 1B2 CA9900006 and M.J. MACBETH Institute for

More information

Ultima. X Series Gas Monitor

Ultima. X Series Gas Monitor Ultima X Series Gas Monitor Safety Manual SIL 2 Certified " The Ultima X Series Gas Monitor is qualified as an SIL 2 device under IEC 61508 and must be installed, used, and maintained in accordance with

More information

Safety Critical Systems

Safety Critical Systems Safety Critical Systems Mostly from: Douglass, Doing Hard Time, developing Real-Time Systems with UML, Objects, Frameworks And Patterns, Addison-Wesley. ISBN 0-201-49837-5 1 Definitions channel a set of

More information

Queue analysis for the toll station of the Öresund fixed link. Pontus Matstoms *

Queue analysis for the toll station of the Öresund fixed link. Pontus Matstoms * Queue analysis for the toll station of the Öresund fixed link Pontus Matstoms * Abstract A new simulation model for queue and capacity analysis of a toll station is presented. The model and its software

More information

ZIN Technologies PHi Engineering Support. PHi-RPT CFD Analysis of Large Bubble Mixing. June 26, 2006

ZIN Technologies PHi Engineering Support. PHi-RPT CFD Analysis of Large Bubble Mixing. June 26, 2006 ZIN Technologies PHi Engineering Support PHi-RPT-0002 CFD Analysis of Large Bubble Mixing Proprietary ZIN Technologies, Inc. For nearly five decades, ZIN Technologies has provided integrated products and

More information

Best Practices for Developing IBIS-AMI Models

Best Practices for Developing IBIS-AMI Models Best Practices for Developing IBIS-AMI Models Walter Katz, SiSoft wkatz@sisoft.com Mike Steinberger, SiSoft msteinb@sisoft.com Todd Westerhoff, SiSoft twesterh@sisoft.com DAC 2010 IBIS Summit Anaheim,

More information

Electrical Equipment Failures Cause & Liability. Prepared by: Robert Abend, PE on 11 August 2014

Electrical Equipment Failures Cause & Liability. Prepared by: Robert Abend, PE on 11 August 2014 Electrical Equipment Failures Cause & Liability Prepared by: Robert Abend, PE on 11 August 2014 About the Author Robert (Bob) Abend gained his initial career experience in the semiconductor component industry

More information

Hydraulic (Subsea) Shuttle Valves

Hydraulic (Subsea) Shuttle Valves SIL SM.009 0 Hydraulic (Subsea) Shuttle Valves Compiled By : G. Elliott, Date: 11/3/2014 Contents Terminology Definitions......3 Acronyms & Abbreviations..4 1. Introduction 5 1.1 Scope 5 1.2 Relevant Standards

More information

Eutectic Plug Valve. SIL Safety Manual. SIL SM.015 Rev 0. Compiled By : G. Elliott, Date: 19/10/2016. Innovative and Reliable Valve & Pump Solutions

Eutectic Plug Valve. SIL Safety Manual. SIL SM.015 Rev 0. Compiled By : G. Elliott, Date: 19/10/2016. Innovative and Reliable Valve & Pump Solutions SIL SM.015 Rev 0 Eutectic Plug Valve Compiled By : G. Elliott, Date: 19/10/2016 Contents Terminology Definitions......3 Acronyms & Abbreviations...4 1. Introduction..5 1.1 Scope 5 1.2 Relevant Standards

More information

NASA AEROSPACE PRESSURE VESSEL SAFETY STANDARD

NASA AEROSPACE PRESSURE VESSEL SAFETY STANDARD NSS/HP-1740.1 This Standard was CANCELLED on Jul 30 2002 22 FEBRUARY 1974 NASA AEROSPACE PRESSURE VESSEL SAFETY STANDARD OFFICE OF SAFETY AND RELIABILITY AND QUALITY ASSURANCE NATIONAL AERONAUTICS AND

More information

Remote sensing standards: their current status and significance for offshore projects

Remote sensing standards: their current status and significance for offshore projects Remote sensing standards: their current status and significance for offshore projects Peter J M Clive Technical Development Consultant SgurrEnergy Ltd 225 Bath Street Glasgow G2 4GZ E: peter.clive@sgurrenergy.com

More information

Leakage Current Testing Is it right for your application?

Leakage Current Testing Is it right for your application? Leakage Current Testing Is it right for your application? Introduction The Leakage Current test (LCT for short) is most often specified to be performed as a type test in a design or engineering laboratory

More information

Questions & Answers About the Operate within Operate within IROLs Standard

Questions & Answers About the Operate within Operate within IROLs Standard Index: Introduction to Standard...3 Expansion on Definitions...5 Questions and Answers...9 Who needs to comply with this standard?...9 When does compliance with this standard start?...10 For a System Operator

More information

TPM TIP. Oil Viscosity

TPM TIP. Oil Viscosity TPM TIP Oil Viscosity TIP #1 Classification according to viscosity is the most prevalent method of describing oils, and the most common classification systems are those of the SAE, AGMA, and ISO. Each

More information

Reliability predictions in product development. Proof Engineering Co

Reliability predictions in product development. Proof Engineering Co Reliability predictions in product development Proof Engineering Co Contents Review of reliability theory Ways to predict part reliability Converting parts reliability into a system reliability Ways to

More information

Elimination of Percent Level H 2 S Calibration Gas from Flare Gas Monitoring Systems Measuring Total Sulfur, H 2 S and BTU.

Elimination of Percent Level H 2 S Calibration Gas from Flare Gas Monitoring Systems Measuring Total Sulfur, H 2 S and BTU. Elimination of Percent Level H 2 S Calibration Gas from Flare Gas Monitoring Systems Measuring Total Sulfur, H 2 S and BTU. Control Analytics, Inc 6017 Enterprise Dr Export, PA 15632 (724) 387 CEMS (2367)

More information

Reliability engineering is the study of the causes, distribution and prediction of failure.

Reliability engineering is the study of the causes, distribution and prediction of failure. Reliability engineering: Reliability is the probability that a system or component will perform without failure for a specified period of time under specified operating conditions. Reliability engineering

More information

Risk Management Series Article 8: Risk Control

Risk Management Series Article 8: Risk Control Risk Management Series Foreword MEDIcept presents this ongoing series of articles focused on the implementation and practical conduct of risk management in the medical device industry to provide practitioners

More information

Helicopter Safety Recommendation Summary for Small Operators

Helicopter Safety Recommendation Summary for Small Operators Helicopter Safety Recommendation Summary for Small Operators Prepared by the International Helicopter Safety Team September 2009 Introduction This document is intended to provide a summary of the initial

More information

Looking Beyond Relief System Design Standards

Looking Beyond Relief System Design Standards Looking Beyond Relief System Design Standards M. Reilly & T. Craddock Introduction A correctly designed relief system is key to safe plant design and operation, ensuring the ability to handle any potential

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Solenoid Drivers KFD2-SL2-(Ex)1.LK.vvcc KFD2-SL2-(Ex)*(.B).vvcc Customer: Pepperl+Fuchs GmbH Mannheim Germany Contract No.: P+F 06/09-23 Report No.:

More information

Addressing DDR5 design challenges with IBIS-AMI modeling techniques

Addressing DDR5 design challenges with IBIS-AMI modeling techniques Addressing DDR5 design challenges with IBIS-AMI modeling techniques Todd Westerhoff, SiSoft Doug Burns, SiSoft Eric Brock, SiSoft DesignCon 2018 IBIS Summit Santa Clara, California February 2, 2018 Agenda

More information

Freak Waves: A Suggested Definition and Possible Consequences for Marine Structures

Freak Waves: A Suggested Definition and Possible Consequences for Marine Structures Freak Waves: A Suggested Definition and Possible Consequences for Marine Structures 1. What is the target safety level of offshore structures? 2. Are rogue waves a problem? A) What is a rogues wave? B)

More information

Hitting The Driver Made Easy

Hitting The Driver Made Easy Table of Contents Introduction 3 Equipment 4 The Golf Shaft 4 The Golf Grip 5 The Club Head 6 Equipment Summary 7 The Setup And Swing 9 The Grip 10 Ball Position 12 Alignment 12 Posture 14 The Take-Away

More information

FP15 Interface Valve. SIL Safety Manual. SIL SM.018 Rev 1. Compiled By : G. Elliott, Date: 30/10/2017. Innovative and Reliable Valve & Pump Solutions

FP15 Interface Valve. SIL Safety Manual. SIL SM.018 Rev 1. Compiled By : G. Elliott, Date: 30/10/2017. Innovative and Reliable Valve & Pump Solutions SIL SM.018 Rev 1 FP15 Interface Valve Compiled By : G. Elliott, Date: 30/10/2017 FP15/L1 FP15/H1 Contents Terminology Definitions......3 Acronyms & Abbreviations...4 1. Introduction...5 1.1 Scope.. 5 1.2

More information

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS APPLICATION NOTE LC-136 Introduction Specialized spaces often times must

More information

A quantitative software testing method for hardware and software integrated systems in safety critical applications

A quantitative software testing method for hardware and software integrated systems in safety critical applications A quantitative software testing method for hardware and software integrated systems in safety critical applications Hai ang a, Lixuan Lu* a a University of Ontario Institute of echnology, Oshawa, ON, Canada

More information

Bespoke Hydraulic Manifold Assembly

Bespoke Hydraulic Manifold Assembly SIL SM.0003 1 Bespoke Hydraulic Manifold Assembly Compiled By : G. Elliott, Date: 12/17/2015 Contents Terminology Definitions......3 Acronyms & Abbreviations..4 1. Introduction 5 1.1 Scope 5 1.2 Relevant

More information

IMCA DP Station Keeping Bulletin 04/18 November 2018

IMCA DP Station Keeping Bulletin 04/18 November 2018 DP STATION KEEPING BULLETIN IMCA DP Station Keeping Bulletin 04/18 November 2018 The following event trees have been compiled from recent reports received by IMCA. The originators granted IMCA permission

More information

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications Application Description AG/266PILD-EN Rev. C 2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic Pressure Measurement Engineered solutions for all applications Increase plant productivity

More information

Solenoid Valves For Gas Service FP02G & FP05G

Solenoid Valves For Gas Service FP02G & FP05G SIL Safety Manual SM.0002 Rev 02 Solenoid Valves For Gas Service FP02G & FP05G Compiled By : G. Elliott, Date: 31/10/2017 Reviewed By : Peter Kyrycz Date: 31/10/2017 Contents Terminology Definitions......3

More information

Using STPA in the Design of a new Manned Spacecraft

Using STPA in the Design of a new Manned Spacecraft Using STPA in the Design of a new Manned Spacecraft Japan Aerospace Exploration Agency (JAXA) Ryo Ujiie 1 Contents Abstract Purpose JAXA s Manned Spacecraft (CRV) JAXA s Experience of STPA STPA in CRV

More information

Adaptability and Fault Tolerance

Adaptability and Fault Tolerance Adaptability and Fault Tolerance Rogério de Lemos University of Kent, UK Context: self-* and dependability; Focus: adaptability and fault tolerance; State of the art; Conclusions; Rogério de Lemos ICSE

More information

PSM I PROFESSIONAL SCRUM MASTER

PSM I PROFESSIONAL SCRUM MASTER PSM I PROFESSIONAL SCRUM MASTER 1 Upon What kind of process control is SCRUM based? a) IDEAL b) SCRUM enterprise c) Empirical d) Agile 2 If burndown charts are used to visualize progress, what do they

More information

Service & Support. Questions and Answers about the Proof Test Interval. Proof Test According to IEC FAQ August Answers for industry.

Service & Support. Questions and Answers about the Proof Test Interval. Proof Test According to IEC FAQ August Answers for industry. Cover sheet Questions and Answers about the Proof Test Interval Proof Test According to IEC 62061 FAQ August 2012 Service & Support Answers for industry. Contents This entry originates from the Siemens

More information

Dieter Krenz, Linde, Germany, Manel Serra, Inprocess, Spain, and. Theron Strange, Simplot Phosphates, USA, discuss dynamic process simulation

Dieter Krenz, Linde, Germany, Manel Serra, Inprocess, Spain, and. Theron Strange, Simplot Phosphates, USA, discuss dynamic process simulation Dieter Krenz, Linde, Germany, Manel Serra, Inprocess, Spain, and Theron Strange, Simplot Phosphates, USA, discuss dynamic process simulation in an ammonia plant startup. P rocess simulation is a technology

More information

Point level switches for safety systems

Point level switches for safety systems Point level switches for safety systems By: Bill Sholette Level Products Business Manager Northeast US - Endress+Hauser Point level switches are often used in applications designed to prevent accidents.

More information

Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST)

Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST) Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST) Application Positioner firmware for early detection of control valve faults giving maintenance recommendations. Valid

More information

Safety Manual OPTISWITCH series relay (DPDT)

Safety Manual OPTISWITCH series relay (DPDT) Safety Manual OPTISWITCH series 5000 - relay (DPDT) 1 Content Content 1 Functional safety 1.1 In general................................ 3 1.2 Planning................................. 5 1.3 Adjustment

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Temperature transmitter PR5337 / PR6337 / PR7501 with 4..20 ma output Customer: PR electronics A/S Rønde Denmark Contract No.: PR electronics A/S

More information

Unit 5: Prioritize and Manage Hazards and Risks STUDENT GUIDE

Unit 5: Prioritize and Manage Hazards and Risks STUDENT GUIDE : Prioritize and Manage Hazards and Risks STUDENT GUIDE Objectives By the end of this unit, students will be able to: Describe several techniques that can be used to prioritize hazards for mitigation,

More information

You Just Experienced an Electrical Failure, What Should You Do Next? By Don Genutis Hampton Tedder Technical Services

You Just Experienced an Electrical Failure, What Should You Do Next? By Don Genutis Hampton Tedder Technical Services You Just Experienced an Electrical Failure, What Should You Do Next? By Don Genutis Hampton Tedder Technical Services Why Failures Occur Insulation Failure - Every electrical component is comprised of

More information

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology: Title: Comparison of Chemical Sensor and NDIR Technologies TSN Number: 25 File:\\MII- SRV1\Metron\Bridge_Analyzers\Customer_Service_Documentation\White_Papers\25_G en EGA NDIR vs Chemical Sensor.docx Created

More information

Investigating the effects of interchanging components used to perform ripple assessments on calibrated vector network analysers

Investigating the effects of interchanging components used to perform ripple assessments on calibrated vector network analysers Abstract Investigating the effects of interchanging components used to perform ripple assessments on calibrated vector network analysers Andrew G Morgan and Nick M Ridler Centre for Electromagnetic and

More information

D-Case Modeling Guide for Target System

D-Case Modeling Guide for Target System D-Case Modeling Guide for Target System 1/32 Table of Contents 1 Scope...4 2 Overview of D-Case and SysML Modeling Guide...4 2.1 Background and Purpose...4 2.2 Target System of Modeling Guide...5 2.3 Constitution

More information

CALIBRATION SYSTEM REQUIREMENTS. ESCC Basic Specification No

CALIBRATION SYSTEM REQUIREMENTS. ESCC Basic Specification No Page 1 of 8 CALIBRATION SYSTEM REQUIREMENTS ESCC Basic Specification Issue 4 February 2014 Document Custodian: European Space Agency see https://escies.org PAGE 2 LEGAL DISCLAIMER AND COPYRIGHT European

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Surge Protective Devices D9324S Customer: G.M. International s.r.l Villasanta Italy Contract No.: GM 16/02-055 Report No.: GM 16/02-055 R005 Version

More information

Pneumatic QEV. SIL Safety Manual SIL SM Compiled By : G. Elliott, Date: 8/19/2015. Innovative and Reliable Valve & Pump Solutions

Pneumatic QEV. SIL Safety Manual SIL SM Compiled By : G. Elliott, Date: 8/19/2015. Innovative and Reliable Valve & Pump Solutions SIL SM.0010 1 Pneumatic QEV Compiled By : G. Elliott, Date: 8/19/2015 Contents Terminology Definitions......3 Acronyms & Abbreviations..4 1. Introduction 5 1.1 Scope 5 1.2 Relevant Standards 5 1.3 Other

More information

Reliability of Safety-Critical Systems Chapter 3. Failures and Failure Analysis

Reliability of Safety-Critical Systems Chapter 3. Failures and Failure Analysis Reliability of Safety-Critical Systems Chapter 3. Failures and Failure Analysis Mary Ann Lundteigen and Marvin Rausand mary.a.lundteigen@ntnu.no RAMS Group Department of Production and Quality Engineering

More information

Improve Process Reliability

Improve Process Reliability Convenient Conductivity Calibration to Meet Pharmacopeia Regulations Pharmacopeias require that conductivity measurement systems be periodically calibrated to ensure their precision. The range of accessories

More information

Data Sheet T 8389 EN. Series 3730 and 3731 Types , , , and. EXPERTplus Valve Diagnostic

Data Sheet T 8389 EN. Series 3730 and 3731 Types , , , and. EXPERTplus Valve Diagnostic Data Sheet T 8389 EN Series 3730 and 3731 Types 3730-2, 3730-3, 3730-4, 3730-5 and Type 3731-3 Electropneumatic Positioners EXPERTplus Valve Diagnostic Application Positioner firmware to detect potential

More information

TRAFFIC CHARACTERISTICS. Unit I

TRAFFIC CHARACTERISTICS. Unit I TRAFFIC CHARACTERISTICS Unit I Traffic stream Characteristics Overview Overview of Traffic Stream Components To begin to understand the functional and operational aspects of traffic on streets and highways

More information

Outside Air Nonresidential HVAC Stakeholder Meeting #2 California Statewide Utility Codes and Standards Program

Outside Air Nonresidential HVAC Stakeholder Meeting #2 California Statewide Utility Codes and Standards Program 1 Outside Air Nonresidential HVAC Stakeholder Meeting #2 California Statewide Utility Codes and Standards Program Jim Meacham, CTG Energetics Agenda 2 In Situ Testing Results Reduced Ventilation after

More information

OIL & GAS. MTS DP Committee. Workshop in Singapore Session 4 Day 2. Unwanted Thrust

OIL & GAS. MTS DP Committee. Workshop in Singapore Session 4 Day 2. Unwanted Thrust OIL & GAS MTS DP Committee Workshop in Singapore 2018 Session 4 Day 2 Unwanted Thrust Unwanted Thrust - Definition Unwanted Thrust Thrust magnitude not what has been ordered by DP (Particularly too high

More information

Advanced LOPA Topics

Advanced LOPA Topics 11 Advanced LOPA Topics 11.1. Purpose The purpose of this chapter is to discuss more complex methods for using the LOPA technique. It is intended for analysts who are competent with applying the basic

More information

Param Express. Param Sankalp December Newsletter winners. Key Activities Concluded. Watch Out For

Param Express. Param Sankalp December Newsletter winners. Key Activities Concluded. Watch Out For Param Express Param Sankalp December Newsletter winners Key Activities Concluded Based on RCM expert input Refinements incorporation is in progress for 1 st set of 10 equipment s. Notification generated

More information

The RCM Analyst - Beyond RCM

The RCM Analyst - Beyond RCM The RCM Analyst - Beyond RCM darylm@strategic-advantages.com About the Author: Daryl Mather was originally trained in RCM in 1991, after which he was involved in the application of the method through a

More information

30 April 2 May 2018 ICC Sydney Unlocking the Future through Systems Engineering. sete2018.com.au. Captain Ross Grafton

30 April 2 May 2018 ICC Sydney Unlocking the Future through Systems Engineering. sete2018.com.au. Captain Ross Grafton 30 April 2 May 2018 ICC Sydney Unlocking the Future through Systems Engineering sete2018.com.au Captain Ross Grafton Lessons Learned in Applying Efficient Test Design and Analysis Techniques to Aircraft

More information

Achieving Compliance in Hardware Fault Tolerance

Achieving Compliance in Hardware Fault Tolerance Mirek Generowicz FS Senior Expert (TÜV Rheinland #183/12) Engineering Manager, I&E Systems Pty Ltd Abstract The functional safety standards ISA S84/IEC 61511 (1 st Edition, 2003) and IEC 61508 both set

More information

Enbridge Pipelines Inc. PIPELINE INTEGRITY AXIAL CRACK THREAT ASSESSMENT

Enbridge Pipelines Inc. PIPELINE INTEGRITY AXIAL CRACK THREAT ASSESSMENT Enbridge Pipelines Inc. Line 9B Reversal and Line 9 Capacity Expansion Project Appendix A to Updated Pipeline Engineering Assessment PIPELINE INTEGRITY AXIAL CRACK THREAT ASSESSMENT Table of Contents 1.

More information

Presented to the Israel Annual Conference on Aerospace Sciences, 2009 RISK-ANALYSIS A SUPPLEMENT TO DAMAGE-TOLERANCE ANALYSIS

Presented to the Israel Annual Conference on Aerospace Sciences, 2009 RISK-ANALYSIS A SUPPLEMENT TO DAMAGE-TOLERANCE ANALYSIS RISK-ANALYSIS A SUPPLEMENT TO DAMAGE-TOLERANCE ANALYSIS Abraham Brot Engineering Division Israel Aerospace Industries Ben-Gurion Airport, Israel abrot@iai.co.il ABSTRACT Risk-analysis, based on probabilistic

More information

Understanding the How, Why, and What of a Safety Integrity Level (SIL)

Understanding the How, Why, and What of a Safety Integrity Level (SIL) Understanding the How, Why, and What of a Safety Integrity Level (SIL) Audio is provided via internet. Please enable your speaker (in all places) and mute your microphone. Understanding the How, Why, and

More information

Mitos Fluika Pressure and Vacuum Pumps Datasheet

Mitos Fluika Pressure and Vacuum Pumps Datasheet Unit 1, Anglian Business Park, Orchard Road, Royston, Hertfordshire, SG8 5TW, UK T: +44 (0)1763 242491 F: +44 (0)1763 246125 E: sales@dolomite-microfluidics.com W: www.dolomite-microfluidics.com Dolomite

More information

Basic STPA Tutorial. John Thomas

Basic STPA Tutorial. John Thomas Basic STPA Tutorial John Thomas How is STAMP different? STAMP Model (Leveson, 2003); (Leveson, 2011) Accidents are more than a chain of events, they involve complex dynamic processes. Treat accidents as

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Solenoid Valves SNMF 532 024 ** ** and SMF 52 024 ** ** Customer: ACG Automation Center Germany GmbH & Co. KG Tettnang Germany Contract No.: ACG

More information

Calculation of Trail Usage from Counter Data

Calculation of Trail Usage from Counter Data 1. Introduction 1 Calculation of Trail Usage from Counter Data 1/17/17 Stephen Martin, Ph.D. Automatic counters are used on trails to measure how many people are using the trail. A fundamental question

More information

Fail Operational Controls for an Independent Metering Valve

Fail Operational Controls for an Independent Metering Valve Group 14 - System Intergration and Safety Paper 14-3 465 Fail Operational Controls for an Independent Metering Valve Michael Rannow Eaton Corporation, 7945 Wallace Rd., Eden Prairie, MN, 55347, email:

More information