bathroom design Playtime shower column integrated head Any queries? Call:

Size: px
Start display at page:

Download "bathroom design Playtime shower column integrated head Any queries? Call:"

Transcription

1 bathroom design Playtime shower column integrated head Any queries? Call:

2 3 2 pers. SDK654 (2x) SDK660 PLT216 SOL226 (4x) SOL227 (6x) SOL651 (2x) SDK659 This part is pre assembled on the water pipe for packaging. Please disassemble. 1/2 outher thread PLT211 PLT206 SOL098 (4x) SOL501 (2x) Installation 4mm SOL661 Please make sure that any debris is flushed out of the pipe work before installation as it can damage the shower. PLT212 Attention: Always start with the installation of your shower enclosure according to the manual. But keep in mind that the outside of the glass must be 858 mm till 888 mm from the wall. 1 2 Attention: The shower crossbeam is only 40 mm thick. Please keep this in mind when tiling around the water outlet. 130 mm 1/2 B H - 10mm H 40 mm mm 1/2 B mm B H =...mm 1 of 3

3 3 4 1/2 Attention: Please use PTFE tape or similar to ensure a waterproof connection. A SOL501 PLT216 6 SOL651 B C SDK660 SDK659 5 Attention: loosely connect the pipe to the water 6 outlet, this will be tightened in step 8 A B A B PLT206 PLT212 C B 7 8 Attention: tighten the water connection and slide the cover over. 3 SDK654 (2x) A B 2 of 3

4 Technical data Bar L/min Maximum operating pressure: 9 Bar Recommended operating pressure: 2-9 Bar Minimum operating pressure: 0.2 Bar When flow rate is 14.1 L/min, the pressure is 3 Bar Hot water temperature max : 75 C Hot water temperature recommended: 65 C Guidelines for cleaning the Playtime shower Please remove all shampoo and soap. Then dry the showerhead. If the showerhead is calcified, you can remove calcification by gently rubbing the silicone nozzles of the showerhead. For cleaning, we recommend to use a very soft, non-abrasive cloth combined with a non-aggressive cleaning agent. Only use cleaning agents suited for sanitary showers and taps. Please use according to the product s instructions. Don t use cleaning agents that contain acids, chlorine or bleach. Neither use abrasive cleaning products. After cleaning, please use water to remove all remaining cleaning agent. Then dry the showerhead. 3 of 3 V03_ _PLT797

5 shower enclosure PlayTime walk-in shower Any queries? Call: D

6 SET 01 SET 02 SET 03 SET /10/20 1x 1x 1x 1x x* 2x* x - 1x x 2x x 2x PLT099 SOL401 (4x) SOL651 (4x) SOL501 (4x) SOL226 (3x) SOL227 (6x) SOL653 (5x) SOL664 (3mm) SOL505 (4x) PLT098 (3x) PLT092 SOL501 (5x) PLT098 SOL651 SOL653 (3x) PLT097 PLT096 PLT062 SOL501 (4x) SOL101 (100cm) SOL102 (120cm) SOL103 (140cm) PLT110 PLT061 PLT091 PLT064 SOL661 (4mm) SOL664 (3mm) /10/

7 SET 01 + side screen* (p. 4-7) SET 02 + side screen* (p. 8-11) Select your shower configuration and proceed to the corresponding pages of this manual. Check the table on the left for the required packaging units. * With SET 01 en SET 02 the side screen is optional. 5 Max. 275cm Max. 275cm SET 03 (p ) SET 04 (p )

8 SET 01 + Side screen* 1a PLT061 2cm 90 / 100cm 100 / 120 / 140cm 1b PLT061 max. 100cm 2 Ø6mm (4x) 3 SOL501 (4x) SOL651 (4x) 4 T s

9 mm (100cm) 1000mm (120cm) 1200mm (140cm) SOL501 Ø6mm 2050mm m 6 7 PLT mm 200mm SOL227 SOL651 8 SOL227 The rubber pads SOL227 may be stacked to level the screen and overcome irregularities of the (tiled) floor. PLT062 SOL101 (100cm) SOL102 (120cm) SOL103 (140cm) 5

10 Ø3,5mm (4x) SOL401 (4x) 25mm (* 32mm) L - 5mm * L PLT SOL664 (3mm) * PLT092 PLT099 SOL661 (4mm) 6

11 15 16 IMPORTANT: Silicone must be applied to both sides of the screen as it will be the sole means of fixation to the floor. * + Side screen *18 *17 SOL227 PLT mm *19 *20 7

12 SET 02 + Side screen* 1a SOL / 120 / 140cm 90 / 100cm 200mm 200mm T s 1b SOL / 120 / 140cm max. 100cm 200mm 200mm When installing directly on to the bathroom floor there are two possibilities: 1b. Placement on the rubber pads SOL227. Silicone has to be applied to the bottom edge with this option. 1c. Placement on blocks PLT098. The bottom edge of the screen will not be sealed off (steps 10 & 11 are cancelled). A gap will remain between the floor and the screen. 1c max. 100cm 100 / 120 / 140cm 200mm 200mm 2x SOL226 NOTE: The blocks PLT098 are mounted to the floor with screws. In case of floor heating we strongly advise against this installation option. SOL501 (2x) Ø6mm (2x) SOL653 8 PLT098

13 2 200mm 200mm 2050mm SOL227 The rubber pads SOL227 may be stacked to level the screen and overcome irregularities of the (tiled) floor. 3 4 SOL501 (2x) Ø6mm (2x) SOL651 (2x) 5 6 L - 5mm L PLT092 (2x) 9

14 7 8 PLT092 (2x) * SOL101 (100cm) SOL102 (120cm) SOL103 (140cm) PLT099 (2x) 9 SOL664 (3mm) 10 * SOL661 (4mm) 11 IMPORTANT: Silicone must be applied to both sides of the screen as it will be the sole means of fixation to the floor. * 10

15 * + Side screen *12b SOL226 2x *12a SOL653 SOL227 SOL501 (2x) Ø6mm (2x) PLT mm 250mm *13 *14 PLT110 (2x) *15 11

16 SET 03 1a PLT061 2cm Max. 275cm 1b 90 / 100cm 100 / 120 / 140cm PLT061 max. 100cm 2 Ø6mm (4x) 3 SOL501 (4x) SOL651 (4x) 12

17 m 4 200mm 200mm SOL227 SOL227 The rubber pads SOL227 may be stacked to level the screen and overcome irregularities of the (tiled) floor. 5 6 PLT062 SOL101 (100cm) SOL102 (120cm) SOL103 (140cm) 32mm 7 8 Ø3,5mm (4x) SOL401 (4x) 13

18 9 10 h - 23mm 1 h PLT091 PLT064 h mm PLT097 4x 1 PLT PLT097 Ø6mm (4x) 1 PLT064 2 SOL501 (4x) PLT091 14

19 15 SOL664 (3mm) 16 1 SOL653 (4x) 2 SOL505 (4x) 17 IMPORTANT: Silicone must be applied to both sides of the screen as it will be the sole means of fixation to the floor. 15

20 SET 04 1a 100 / 120 / 140cm PLT098 25mm 35mm Max. 275cm 1b 100 / 120 / 140cm PLT098 25mm 35mm When installing the screen directly on to the bathroom floor there are two possibilities: 1c 1b. The block PLT098 is mounted with double sided adhesive tape which is already applied to the block. 1c. The block PLT098 is screwed directly into the bathroom floor. In case of floor heating we strongly advise against this installation option. 25mm 35mm SOL653 NOTE: 16 In both cases the mounting of the floor block is merely an installation help to keep the profile PLT091 in place. The final fixation of the screen will be realized by the application of the silicone seal (step 17). SOL501 (2x) Ø6mm (2x) PLT098

21 2 3 h - 23mm h PLT091 (2x) PLT064 (2x) h mm 4 PLT x PLT PLT PLT097 Ø6mm (4x) 1 PLT064 2 SOL501 (4x) PLT091 17

22 8 SOL664 (3mm) SOL653 (4x) 2 SOL227 SOL505 (4x) 10 1 SOL227 SOL101 (100cm) SOL102 (120cm) SOL103 (140cm) The rubber pads SOL227 may be stacked to level the screen and overcome irregularities of the (tiled) floor. 11 PLT x PLT

23 13 14 PLT097 Ø6mm (4x) PLT064 1 SOL501 (4x) 2 PLT SOL664 (3mm) 16 2 SOL653 (4x) 1 SOL505 (4x) 17 IMPORTANT: Silicone must be applied to both sides of the screen as it will be the sole means of fixation to the floor. 19

24 v D

shower enclosure PlayTime walk-in shower Any queries? Call:

shower enclosure PlayTime walk-in shower   Any queries? Call: shower enclosure PlayTime walk-in shower D www.bathstore.com Any queries? Call: 08000 3 3 3 SET 0 SET 0 SET 03 SET 04 5000030700/0/0 x x x x 5000030800 x* x* - - 500003080 x - x - 500003080 x x - - 5000030830

More information

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web: EZI-DRY Pty Limited ABN: 98 114 507 443 PO Box 370 Phone: 0249711993 Swansea NSW 2281 Fax: 0249135490 AUSTRALIA Mobile: 0427587900 Web: www.ezi-dry.com.au Email: ezidry@exemail.com.au INSTRUCTION MANUAL

More information

3.5 litr es per INSTALLATION INSTRUCTIONS. Avon 21 Self-closing taps (Push button) B0992AA Self-closing basin pillar tap

3.5 litr es per INSTALLATION INSTRUCTIONS. Avon 21 Self-closing taps (Push button) B0992AA Self-closing basin pillar tap Avon 21 Self-closing taps (Push button) INSTALLATION INSTRUCTIONS B0992AA Self-closing basin pillar tap WaterMark AS/NZS 3718 WMK 25822 SAI Global The more stars the more water efficient WATER RATING www.waterrating.gov.au

More information

Ligature Resistant Head

Ligature Resistant Head Ligature Resistant Head PRODUCT MANUAL IMPORTANT INSTALLER: This product manual is the property of the customer and must be retained with the product for maintenance and operational purposes. 1 Contents

More information

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM Valve Model No's: 1-741, 1-742, 1-743, 1-744 1-741 1-742 1-743 1-744 2001 CARNEGIE AVE, SANTA ANA CA 92705 (949) 417-5207 WWW.NEWPORTBRASS.COM

More information

INSTALLATION GUIDELINES

INSTALLATION GUIDELINES STYLE No. UNWD10 Universal Traditional One Hole Instant Hot and Filtered with Metal STYLE No. UNWD30 Universal Industrial One Hole Instant Hot and Filtered cold Water Dispenser with Metal STYLE No. UNWD50

More information

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer 955751.book : t95575.fm Seite 1 Mittwoch, September 20, 2000 10:10 AM Avensys Exposed Single Lever Mixer 33 389 33 396 Installation Instructions and Operating Guide Please leave this document with the

More information

INSTALLATION GUIDELINES

INSTALLATION GUIDELINES STYLE No. UNWD11 Universal Traditional One Hole Instant Hot Water Dispenser with Metal Lever Handle STYLE No. UNWD31 Universal Industrial One Hole Instant Hot Water Dispenser with Metal Lever Handle STYLE

More information

WHERE TO INSTALL THIS MIRROR

WHERE TO INSTALL THIS MIRROR ROUND LED MIRRORS 3003-L-60 3005-L-60 BEFORE YOU START, HERE IS SOME IMPORTANT INFORMATION. 1) General Information Please inspect this product upon delivery. Any missing parts or manufacturing defects

More information

Jet Swim Installation instruction

Jet Swim Installation instruction Jet Swim 2000 Jet Swim 2000 Liner pool 1. Remove the stainless steel front plate and cut out the pool wall according to the hole pattern. The center of the Jet Swim housing must be a minimum of 170 mm

More information

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER Installation, Operating & Maintenance Instructions EW1050 I00232_Mar 2016 NOTE: THIS DOCUMENT IS TO BE LEFT ONSITE WITH FACILITY MANAGER AFTER INSTALLATION

More information

Pressure Balance Trim

Pressure Balance Trim P24015, P24016, P24115, P24116, P24215, P24216, P24415, P24416 1 of 5 IMPORTANT INSTRUCTIONS READ AND SAVE FOR THE CONSUMER WARNING: Risk of scalding or other severe injury. Before completing installation,

More information

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION This Fitting Guide is designed to assist in the Installation of your Reverse Osmosis System. Some of the parts that are supplied with each system may

More information

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents bathrooms.com Concentric Thermostatic Shower Mixers Contents Page 3 - General Information & Safety Page 4 - Installation Page 5 - Concentric Valve Set-up Page 6 - Exposed fitting of Concentric Mixer Valves

More information

HORNE 20 THERMOSTATIC MIXING VALVE TYPE H-2003

HORNE 20 THERMOSTATIC MIXING VALVE TYPE H-2003 PO Box 7, Rankine Street Johnstone, Renfrewshire Scotland. PA5 8BD Tel: 01505 321 455 Fax: 01505 336 287 Email: technical@horne.co.uk Web: www.horne.co.uk HORNE 20 THERMOSTATIC MIXING VALVE TYPE H-2003

More information

PRODUCT CARD WALL MOUNTED FIXED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,00 TO 2,25 M

PRODUCT CARD WALL MOUNTED FIXED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,00 TO 2,25 M PRODUCT CARD WALL MOUNTED FIXED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,00 TO 2,25 M I. List of components... 2 II. Complimentary products... 2 III. Product description... 3 IV. Product Purpose... 3

More information

PRODUCT CARD WALL MOUNTED SIDE FOLDED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,2 TO 2,45 M

PRODUCT CARD WALL MOUNTED SIDE FOLDED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,2 TO 2,45 M PRODUCT CARD WALL MOUNTED SIDE FOLDED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,2 TO 2,45 M I. List of components... 2 II. Complimentary products... 2 III. Product description... 3 IV. Product Purpose...

More information

GV Standard X-Vent. Setup, Commissioning & Installation Guide

GV Standard X-Vent. Setup, Commissioning & Installation Guide GV Standard X-Vent Setup, Commissioning & Installation Guide Technical experts in the design, manufacture and supply of precision engineered, architectural rooflights for residential and commercial buildings.

More information

INSTRUCTION MANUAL. Gas Salamander

INSTRUCTION MANUAL. Gas Salamander INSTRUCTION MANUAL Gas Salamander This manual contains important information regarding your unit. Please read this manual thoroughly prior to equipment set-up, operation and maintenance. Failure to comply

More information

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL ATD-8402 90LB PRESSURE BLASTER INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS SAFETY INSTRUCTIONS FOR SANDBLASTER 1. Before opening the tank release the air pressure on the sand tank. To do this, turn off

More information

APP pumps APP and APP Disassembling and assembling

APP pumps APP and APP Disassembling and assembling Service guide APP pumps APP 11-13 and APP 16-22 Disassembling and assembling hpp.danfoss.com Table of Contents Contents 1. Introduction... 2 2. Disassembling the pump... 3 3. Assembling the pump... 6 4.

More information

MyControl Bathing System Signature Series

MyControl Bathing System Signature Series MyControl Bathing System Signature Series Touch Assist Touch Pad and CM Technologies Seal Pressure Regulation Instructions Acceptable seal inflation pressure setting must be varified, and adjusted if necessary,

More information

TEMPERATURE STABILISED THERMOSTATIC SHOWER PANEL

TEMPERATURE STABILISED THERMOSTATIC SHOWER PANEL Product Support Guarantee This product is guaranteed against faulty materials and workmanship for 12 months from date of purchase. For the guarantee to be valid, the unit must be installed by a competent

More information

CentriFlow Meter Integrated Air Entrainment System

CentriFlow Meter Integrated Air Entrainment System CentriFlow Meter Integrated Air Entrainment System INSTALLATION & OPERATION MANUAL January 2004 Revision 021-4 EASTERN INSTRUMENTS 416 LANDMARK DR. WILMINGTON, NC 28412 910-392-2490 Fax: 910-392-2123 website:

More information

Chemical Injection Technologies Installation/Service Bulletin

Chemical Injection Technologies Installation/Service Bulletin Bulletin 4002 Chemical Injection Technologies Installation/Service Bulletin SUPERIOR Series CL-16/26/56 Automatic Switchover Gas Chlorinator - Installation & Operation IMPORTANT!! READ THESE PRECAUTIONS

More information

Thank you for choosing Xuma.

Thank you for choosing Xuma. WPC-150 WPC-160 Waterproof Pouch for iphone 6, iphone 6 Plus, and other Smartphones User Manual 1 Welcome Thank you for choosing Xuma. This Xuma Waterproof Pouch keeps your smartphone protected and dry

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS TYPE BV2-LD

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS TYPE BV2-LD INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS TYPE BV2-LD 1. Storage & Protection 1.1. Storage The valves stay in the open position during the transportation. For incoming QC must check: a. Packing

More information

F776 IM_v4_ F776 INSTRUCTIONS. Liberty Security Gate Kit. With Stay-Open Feature & Additional 9cm Extension

F776 IM_v4_ F776 INSTRUCTIONS. Liberty Security Gate Kit. With Stay-Open Feature & Additional 9cm Extension F776 IM_v4_022016 INSTRUCTIONS F776 Liberty Security Kit With Stay-Open Feature & Additional 9cm Extension IMPORTANT! READ AND FOLLOW THESE INSTRUCTIONS CAREFULLY AND KEEP FOR FUTURE REFERENCE If you sell

More information

OPERATING MANUAL. Contents. Bottom outlet ball valve Type ecoline

OPERATING MANUAL. Contents. Bottom outlet ball valve Type ecoline OPERATING MANUAL Bottom outlet ball valve Type ecoline Contents 1 General Information 2 Safety 3 Packing, Handling, Storing 4 Product description 5 Preparation, Assembly 6 Commissioning 7 Handling 8 Attendance

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Instrument Supply Pressure System Model WIC The information in this manual has been carefully checked for accuracy and is intended to be used as a

More information

M03 WUNDATRADE. Heat Pump Manifold. Before you start: Check the contents. Optional. ...a division of WUNDA GROUP PLC

M03 WUNDATRADE. Heat Pump Manifold. Before you start:  Check the contents. Optional. ...a division of WUNDA GROUP PLC Before you start: Check the manifold box contents against the list below. Check the contents Flow gauges 1. Bar assembly with manual return valves 2. 2 x Auto air vent & drain hose attachments Optional

More information

Solar panel. C ground profile (N-S) Omega ballast plate

Solar panel. C ground profile (N-S) Omega ballast plate Instruction Manual AvaSolar -Roof (patent: 1018790 A3) 1 Parts 8 4 3 1 2 7 9 5 6 1 Mounting brackets AvaSolar -Roof 4 Solar panel 7 L-profile 2 AvaSolar -cover 5 C ground profile (N-S) 8 Clamps 3 AvaSolar

More information

Model 405 &407 Small Animal Ventilator. User Manual v3.5

Model 405 &407 Small Animal Ventilator. User Manual v3.5 Model 405 &407 Small Animal Ventilator User Manual v3.5 First of all, sincerely thanks for selecting the RWD405 or RWD407 small animal ventilator made by RWD company. Please read this instruction manual

More information

Twin & Triple Control Concealed Thermostatic Shower Valve

Twin & Triple Control Concealed Thermostatic Shower Valve Twin & Triple Control Concealed Thermostatic Shower Valve Installation & Operating Guide Please leave this installation & user guide with the end user CONTENTS: 1. Introduction & Safety 1 2. Dimensions

More information

COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL

COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL SPECIFICATIONS: The CARD series air valves are available in 3 pipe sizes, 1, 2 and 4 NPT or socket. Maximum inlet pressure

More information

Shifting Lever. RAPIDFIRE Plus 11-speed

Shifting Lever. RAPIDFIRE Plus 11-speed (English) DM-SL0005-04 Shifting Lever Dealer's Manual RAPIDFIRE Plus 11-speed MTB XTR SL-M9000 DEORE XT SL-M8000 CONTENTS IMPORTANT NOTICE... 3 TO ENSURE SAFETY... 4 LIST OF TOOLS TO BE USED... 7 INSTALLATION...

More information

PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH

PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH Installation, Operating & Maintenance Instructions EEE180 EEE210 EFE360 EFE390 ENBE180 ENBE210 ENBE360 ENBE390 I00011_Apr 18 NOTE: THIS DOCUMENT IS TO BE

More information

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer Inflatable Packer Single & Double Single & Double Packer Dimension Wireline Packer Water Testing Packer (WTP) Packer Packer Working Pressure & Depth Chart Packer Water Hand Pump Packer Air Driven Pump

More information

Instrument Operating Manual

Instrument Operating Manual Instrument Operating Manual INDEX NO. SUBJECT PAGE 1 INFORMATION 3 2 SAFETY 4 3 INTENDED USE 4 4 COMMISSIONING & OPERATION 5 5 MAINTENANCE 6 2 INFORMATION The pressure gauges described in the operating

More information

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text. SECTION 10185 SHOWER AND BATH ENCLOSURES Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES A. Bathtub wall enclosures. B. Shower wall

More information

5to: 4-600, 1000, 1200 psi. User s Guide. Phoenix Vessel Technology Limited. End port pressure vessels Model numbers: 1386, 1384, 1703, 1707.

5to: 4-600, 1000, 1200 psi. User s Guide. Phoenix Vessel Technology Limited. End port pressure vessels Model numbers: 1386, 1384, 1703, 1707. User s Guide 5to: Phoenix Vessel Technology Limited 4-600, 1000, 1200 psi End port pressure vessels Model numbers: 1386, 1384, 1703, 1707. Phoenix Vessel Technology Limited Unit 2, The Old Bakery, Lower

More information

Booster Pump PB4-60 Replacement Kits

Booster Pump PB4-60 Replacement Kits Booster Pump PB4-60 Replacement Kits FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product

More information

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15 ASSEMBLING PROCEDURE AND VALVE MAINTENANCE 1.0.... Safety Information 2.0.. INTRODUCTION 3.0 VARIATIONS 4.0..ASSEMBLING PROCEDURE FOR THE STEM 5.0 ASSEMBLING PROCEDURE FOR OUTLET CONNECTIONS 6.0 PROCEDURE

More information

These instructions are to be left with the user

These instructions are to be left with the user MIRA ENERGISE AND MIRA L10 SHOWER FITTINGS INSTALLATION & USER GUIDE These instructions are to be left with the user 1 CONTENTS Introduction 2 General 2 Design Registration 2 Pack Contents 3 Specifications

More information

Design Requirements for Eyewash and Safety Shower Units

Design Requirements for Eyewash and Safety Shower Units Design Requirements for Eyewash and Safety Shower Units Application: Eyewash Stations must be provided in the following areas. Laboratories Plumbed emergency eyewash equipment shall be installed in every

More information

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max Table of Contents Introduction 1. Description of Functions 2. Putting into Operation 3. Instructions for

More information

Horne Engineering Ltd

Horne Engineering Ltd Horne Engineering Ltd Po Box 7, Rankine Street Johnstone, Renfrewshire Scotland, PA5 8BD Tel: 01505 321455 Fax: 01505 336287 Email: technical@horne.co.uk Web: www.horne.co.uk HORNE T105A/106A/107A/108A

More information

3190A NEO-ANGLE DOOR INSTALLATION INSTRUCTIONS. Series MODEL NO

3190A NEO-ANGLE DOOR INSTALLATION INSTRUCTIONS. Series MODEL NO NEO-ANGLE DOOR INSTALLATION INSTRUCTIONS Series 30A Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation sequences. The Exploded Diagram

More information

STAINLESS STEEL OVERFLOW VALVE TYPE 417

STAINLESS STEEL OVERFLOW VALVE TYPE 417 MAIN CHARACTERISTICS The 417 valve is intended for the discharge of fluids overflow when an upstream limitation of pressure is looked for, for example downstream to a pump. This valve also works in presence

More information

275 RID Assembly Instructions

275 RID Assembly Instructions 75 RID Assembly Instructions Part No. 0003003 v. Lscsep0 PARTS LIST (Specifications and contents subject to change without notice) Description Part # A. RID Track...0000050 B. Capacity Plate...0053 C.

More information

Duo/Trio Office Bike Owner s Manual

Duo/Trio Office Bike Owner s Manual Duo/Trio Office Bike Owner s Manual Welcome Congratulations on choosing to enhance your productivity and wellness with LifeSpan. You ve made a healthy decision, as the need for increased amounts of daily

More information

Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Dump Valve Service Kit for Series 2300 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit

More information

SLIPPER & ROLL-TOP FREESTANDING BATHS

SLIPPER & ROLL-TOP FREESTANDING BATHS SLIPPER & ROLL-TOP FREESTANDING BATHS JINS0051 PLEASE NOTE THIS PRODUCT REQUIRES 2 PERSONS OR MORE TO LIFT AND MANOUEVRE THIS PRODUCT INTO POSITION. The installation of freestanding baths will necessitate

More information

SEAGULL IV X-1F Drinking Water Purification System

SEAGULL IV X-1F Drinking Water Purification System supersedes 200712Ax-1f-i&o SEAGULL IV X-1F Drinking Water Purification System INSTALLATION AND PRODUCT USE GUIDE Installation Instructions NOTE: Read instructions completely before starting. General Ecology

More information

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) THE BP-301 SERIES Operating and Service Manual Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) Issue B October 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation...

More information

Steel Spring Driven Reel Instruction Manual

Steel Spring Driven Reel Instruction Manual Steel Spring Driven Reel Instruction Manual WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in

More information

These instructions are to be left with the user

These instructions are to be left with the user MIRA ECO SHOWER FITTINGS INSTALLATION & USER GUIDE These instructions are to be left with the user 1 CONTENTS Introduction 2 General 2 Pack Contents 3 Pack Contents 4 Specifications 5 Pressures 5 Dimensions

More information

Chlorinator. MODEL C-731 (Floor Mounted)

Chlorinator. MODEL C-731 (Floor Mounted) Chlorinator MODEL C-731 (Floor Mounted) CHLOROTECH Model C-731 is the advance technology Chlorinator designed to feed chlorine gas at a controlled rate. The flow rate of gas is maintained by constant positive

More information

MIL Dome Port with

MIL Dome Port with 5516.15 MIL Dome Port with Zoom - I n s t r u c t i o n M a n u a l The 5516.15 MIL Dome Port with Zoom is an optical-grade 6-inch diameter acrylic dome. A Zoom Sleeve (not included) is required to operate

More information

ULTRAMAGIC, S.A. MAINTENANCE MANUAL SUPPLEMENT NUMBER 14 INTRODUCTION OF A VAPOUR PILOT VALVE OPTION FOR THE ULTRAMAGIC MK 21 RANGE OF BURNERS

ULTRAMAGIC, S.A. MAINTENANCE MANUAL SUPPLEMENT NUMBER 14 INTRODUCTION OF A VAPOUR PILOT VALVE OPTION FOR THE ULTRAMAGIC MK 21 RANGE OF BURNERS S14.1 INTRODUCTION OF A FOR THE ULTRAMAGIC MK 21 RANGE OF BURNERS Section 1 1.0 Introduction This supplement defines the maintenance and inspection requirements for the range of Ultramagic MK 21 burners

More information

Regulators repair and maintenance. XS Compact 2nd stage. January 2014 Rev XSC /3 Ed. C /14 1

Regulators repair and maintenance. XS Compact 2nd stage. January 2014 Rev XSC /3 Ed. C /14 1 XS Compact 2nd stage January 2014 Rev XSC /3 Ed. C /14 1 XS Compact 2nd stage WARNING! This manual is intended for use by expert technicians who have already received training in equipment repairs and

More information

Balloon Gastrostomy (BG) Tube

Balloon Gastrostomy (BG) Tube Balloon Gastrostomy (BG) Tube Post insertion advice Please follow hospital/ Consultant advice for care of the tube and stoma site for the first 28 days (if the BG tube has been placed as a first gastrostomy

More information

Pressure Dump Valve Service Kit for Series 3000 Units

Pressure Dump Valve Service Kit for Series 3000 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 000 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00, 400, 500, and 700 applicator

More information

Pneumatic spool valve islands

Pneumatic spool valve islands Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their

More information

PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING!

PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING! PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING! Read and understand instructions before using Petersen Plugs. Failure to comply may result in property damage, serious

More information

INSTRUCTION MANUAL. Thanks for purchasing our airbrush compressor and please read this

INSTRUCTION MANUAL. Thanks for purchasing our airbrush compressor and please read this INSTRUCTION MANUAL AIRBRUSH COMPRESSOR AS-48A Thanks for purchasing our airbrush compressor and please read this Instruction Manual carefully and thoroughly before operating the tool to get best performance.

More information

Dual Pivot Caliper Brake

Dual Pivot Caliper Brake (English) DM-RBBR001-01 Dealer's Manual ROAD MTB Trekking City Touring/ Comfort Bike URBAN SPORT E-BIKE Dual Pivot Caliper Brake SORA BL-R3000 BR-R3000 CLARIS BL-R2000 BR-R2000 Brake cable BC-1051 CONTENTS

More information

k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax

k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax aylesbury k valve installation guide For valve sizes (DN): 2 (50)HF 2½ (65)SF 3 (80)RB IMPORTANT Please keep for future reference. PLEASE READ THESE INSTRUCTIONS CAREFULLY AND REFER TO ANY DIAGRAMS BEFORE

More information

Specialists in HTM Medical Gas Pipeline Equipment AVSU/Module Operating and Maintenance Instructions

Specialists in HTM Medical Gas Pipeline Equipment AVSU/Module Operating and Maintenance Instructions The Area Value Service Units and Module format (AVSU) provide a local gas isolation facility for use during normal installation and maintenance or in the event of an emergency. They are built in accordance

More information

2019 MADONE ASSEMBLY MANUAL

2019 MADONE ASSEMBLY MANUAL 2019 MADONE ASSEMBLY MANUAL 2019 MADONE Rim brakes and Di2 drivetrain Rim brakes and mechanical drivetrain Disc brakes and Di2 drivetrain Disc brakes and mechanical drivetrain TABLE OF CONTENTS Common

More information

Service and Repair Manual

Service and Repair Manual II stage R2 Ice/ Special, II stage R 1 Pro DOWNSTREAM 2 nd STAGE REGULATOR Service and Repair Manual Introduction Safety Precautions...4 General Procedures, Maintenance Schedules...5 Initial Inspection

More information

PENBERTHY SUBMERSIBLE AUTOMATIC SUMP DRAINER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

PENBERTHY SUBMERSIBLE AUTOMATIC SUMP DRAINER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Before installation, these instructions must be read carefully and understood. PRODUCT WARRANTY Emerson warrants its Penberthy products as designed and manufactured to be free of defects in the material

More information

Disassembling and assembling APP and APP 16-22

Disassembling and assembling APP and APP 16-22 MAKING MODERN LIVING POSSIBLE Instruction Disassembling and assembling APP 11-13 and APP 16-22 ro-solutions.com Table of Contents 1. Disassembling...3 2. Disassembling the pump...3 3. Assembling the pump....7

More information

Thermostatic Mixing Valves 61022CPB & 61028CPB Intamix Pro V

Thermostatic Mixing Valves 61022CPB & 61028CPB Intamix Pro V Thermostatic Mixing Valves 61022CPB & 61028CPB Intamix Pro V Installation and Maintenance Instructions 2 1 MIN MAX 7 In this procedure document we have endeavoured to make the information as accurate as

More information

VERTICAL SURFBOARD CARRIER READ ME! IMPORTANT WARNING!

VERTICAL SURFBOARD CARRIER READ ME! IMPORTANT WARNING! VERTICAL SURFBOARD CARRIER ENG RRAC09 30 min READ ME! Thank you for purchasing a Front Runner Vertical Surfboard Carrier. Before you start, take a moment to familiarize yourself with this Fitting Instruction

More information

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL Instruction for use Thank you for selecting an AVK product. With correct use, the product is guaranteed to deliver a long and reliable service. This manual has been prepared to assist you with the installation,

More information

Tripod Setup Guide (M-TPx)

Tripod Setup Guide (M-TPx) Items needed: 1/2 inch wrench, mast level (M-MLA), medium size wire cutters, crescent wrench, all-purpose grease, tape measure, tie wraps, redi-mix cement (optional), shovel (optional), sledge hammer (for

More information

Compact Ball Valves ASAHI AV VALVES. Contents. User s Manual. (Page) (1) Be sure to read the following warranty clauses of our product 1

Compact Ball Valves ASAHI AV VALVES. Contents. User s Manual. (Page) (1) Be sure to read the following warranty clauses of our product 1 Serial No. H-V030-E-5 Compact Ball Valves User s Manual Contents (Page) (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions

More information

NICROS-GRANITPANELS INSTALLATION MANUAL

NICROS-GRANITPANELS INSTALLATION MANUAL NICROS-GRANITPANELS INSTALLATION MANUAL NICROS, INC. 845 PHALEN BLVD. ST. PAUL, MN 55106 PHONE: 651.778.1975 FAX: 651.778.8080 THANK YOU FOR YOUR PURCHASE OF THIS NICROS PRODUCT Nicros-GranitPanels are

More information

PRO SINK -R 1 and 2. Dilution system CONTENTS

PRO SINK -R 1 and 2. Dilution system CONTENTS PRO SINK -R 1 and 2 Dilution system CONTENTS 1.0 Product description 2 2.0 Warnings.. 3 3.0 Installation procedure 4 4.0 Plumbing connections 4 5.0 Technical features.. 5 6.0 Maintenance... 6 7.0 Troubleshooting......6

More information

Installation Guide. buoy.ai

Installation Guide. buoy.ai Installation Guide buoy.ai Notes In the Box Buoy unit Battery and Charger assembly 3/4 meter couplings (2) Rubber gaskets (6) Also included: Buoy Quick Start Guide Buoy Installation Guide Buoy sticker

More information

INSTALLATION & MAINTENANCE INSTRUCTION

INSTALLATION & MAINTENANCE INSTRUCTION ARCHON Industries, Inc Liquid Level Gauges Models: BT-LLG ND-LLG INSTALLATION & MAINTENANCE INSTRUCTION Instruction No.: 1014.2 Revision Issued: 3/01/03 Approved: Engineering Manager Warning ONLY QUALIFIED

More information

Combination Air Valve

Combination Air Valve Combination Air Valve For Sewage and Wastewater Model C50 Installation, Operation and Maintenance Manual (IOM) Table of Contents General... Page 2 Safety... Page 2 Operational Data... Page 3 Materials

More information

Mooney * Noise Controller Installation, Operation, and Maintenance Manual

Mooney * Noise Controller Installation, Operation, and Maintenance Manual GE Oil & Gas Mooney * Noise Controller Installation, Operation, and Maintenance Manual imagination at work Scope This manual provides instructions for installation, operation and maintenance of the Mooney

More information

DM-RCWH (English) Dealer's Manual. ROAD MTB Trekking. City Touring/ Comfort Bike. Wheel Set. WH-RX31 SM-AX x12 SM-AX x12

DM-RCWH (English) Dealer's Manual. ROAD MTB Trekking. City Touring/ Comfort Bike. Wheel Set. WH-RX31 SM-AX x12 SM-AX x12 (English) DM-RCWH001-00 Dealer's Manual ROAD MTB Trekking City Touring/ Comfort Bike URBAN SPORT E-BIKE Wheel Set WH-RX31 SM-AX720-100x12 SM-AX720-142x12 CONTENTS IMPORTANT NOTICE... 3 TO ENSURE SAFETY...

More information

Geotech 1.66 Reclaimer

Geotech 1.66 Reclaimer Geotech 1.66 Reclaimer Installation and Operation Manual Rev 7/1/18 Part # 66 Table of Contents DOCUMENTATION CONVENTIONS... Section 1: System Description... 3 Section : System Installation... 4 Section

More information

Final Assembly Instructions Bikes with 16 Wheel Size

Final Assembly Instructions Bikes with 16 Wheel Size Final Assembly Instructions Bikes with 16 Wheel Size Thank you for buying your new bicycle from L.L.Bean. Read these instructions carefully before beginning the final assembly. Prior to shipping, our expert

More information

SOLO TRIPOD SERIES Operator s Manual

SOLO TRIPOD SERIES Operator s Manual SOLO TRIPOD SERIES Operator s Manual #1630 Solo DV 75mm 2-Stage Alloy Tripod #1501 Solo DV 75mm 2-Stage Carbon Fibre Tripod #1505 Solo ENG 100mm 3-Stage Tripod Features and Controls 75mm Bowl (#1501 &

More information

SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER

SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER CONTENTS 1. INTRODUCTION & SAFETY 1 2. DIMENSIONS 2 3. TECHNICAL DATA 3 4. OPERATION 4 5. COMPONENTS 5 6. SITE INSTALLATION

More information

Versatile, user friendly all glass sliding revolving door w26-c Maintenance Instructions and Directions for Use

Versatile, user friendly all glass sliding revolving door w26-c Maintenance Instructions and Directions for Use Versatile, user friendly all glass sliding revolving door w26-c Maintenance Instructions and Directions for Use Important guidelines for specialist retailers and end users Please read carefully and bear

More information

Overhead Irrigation Installation Guide DOM Copyright First Tunnels Ltd 2012.

Overhead Irrigation Installation Guide DOM Copyright First Tunnels Ltd 2012. www.firsttunnels.co.uk/quality Overhead Irrigation Installation Guide DOM Copyright First Tunnels Ltd 2012. Warnings General Please keep children and pets away from the work area. If any holes are not

More information

PoolLock Easy Pool Cover

PoolLock Easy Pool Cover PoolLock Easy Pool Cover INSTALLATION MANUAL The packaging of the PoolLock Easy Cover contains: 1. PoolLock Easy cover (rolled up) 2. One or two manual cranks (according to the pool size) Plastic bag contains:

More information

American Flagpole & Flag Co. 1(800)

American Flagpole & Flag Co.   1(800) SENTRY CONCEALED HALYARD-REVOLVING TRUCK GROUND SET INSTALLATIONS INSTRUCTIONS 1. Dig foundation as detailed in SECTION A FOUNDATION SPECIFICATIONS, set sleeve in enter of hole with top 2 above grade.

More information

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION IMPORTANT All tapware and showers to be installed by a licensed plumber and to Australian Standards. Fit tempering and pressure reduction

More information

Bar valve with fixed shower head Installation guide

Bar valve with fixed shower head Installation guide Midas Plus Mono Bar valve with fixed shower head Installation guide Midas Plus Mono Midas Plus Mono Components Literature not shown Important information Introduction The Midas Plus Mono product is an

More information

INSTALLING THE PROWLER 13 RUDDER

INSTALLING THE PROWLER 13 RUDDER INSTALLING THE PROWLER 13 RUDDER Parts Included: Steering Parts: Foot Rail Parts: Rudder Parts: Retraction Parts: 4 Rubber 2 Rail Assemblies Rudder Body 1 Rudder Retraction Grommets (includes steering

More information

Technical Service Bulletin June 2015 TSB122.06

Technical Service Bulletin June 2015 TSB122.06 Technical Service Bulletin June 2015 TSB122.06 Element Loading Guidelines This bulletin provides general information and guidelines for installing Hydranautics elements in order to provide optimally reliable

More information

BIMBAR INFLATABLE PACKERS AND ACCESSORIES

BIMBAR INFLATABLE PACKERS AND ACCESSORIES BIMBAR INFLATABLE PACKERS AND ACCESSORIES Geopro supplies a complete range of inflatable packers in nine different diameters from 28 up to 170mm. All our packers made of BIMBAR rubber technology are reinforced

More information

INSTALLATION & MAINTENANCE INSTRUCTIONS

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The QBX series valve uses Proportion-Air closed loop technology for Pressure control. It gives an output pressure proportional to an electrical command signal input. The QB1X

More information

Tripod Series OPERATOR S MANUAL

Tripod Series OPERATOR S MANUAL Tripod Series OPERATOR S MANUAL #1630 - Solo 75 2-Stage Tripod (Alloy) #1501 - Solo 75 2-Stage Tripod #2001 - Solo 75 3-Stage Tripod #1505 - Solo 100 3-Stage Tripod Features and Controls 75mm Bowl or 100mm

More information