Shock Absorber Accessories M5 to M25

Size: px
Start display at page:

Download "Shock Absorber Accessories M5 to M25"

Transcription

1 Shock Absorber Accessories M to M Selection Chart for Shock Absorber Accessories 1 / 2 Side Load Adaptor Shock Absorber Type KM AH MB RF UM BV Thread Size Mx0. MCEUM KM AH MBSC2 Thread Size Mx0. MC9EUM KM AH MBSC2 RF Thread Size Mx1 MA0EUM KM AH MBSC2 RF BV MCEUM KM AH MBSC2 RF BVA MC0EUM KM AH MBSC2 RF BV Thread Size Mx1 FA0VD-B KM AH MBSC2 RF UM MA0EUM KM AH MBSC2 RF UM BV MCEUM KM AH MBSC2 RF UM BV SCEUM KM AH MBSC2 RF UM BVSC Thread Size Mx1 MAEUM KM AH MB RF UM BV MC7EUM KM AH MB RF UM BV SC7EUM KM AH MBSC2 RF UM BVSC Thread Size MA0EUM KM AH MB RF UM BV MC0EUM KM AH MB RF UM BV SC190EUM0-4 KM AH MB RF UM BVSC SC190EUM-7 KM AH MBSC2 RF UM BV Thread Size Mx1. MA2EUM KM AH MB RF UM BVSC MC2EUM KM AH MB RF UM BV SC00EUM0-4 KM AH MB RF UM BVSC SC00EUM-9 KM AH MBSC2 RF UM BVSC Thread Size Mx1. MA00EUM KM AH MB RF UM BVSC MA900EUM KM AH MB RF UM MC00EUM KM AH MB RF UM BV SC0EUM0-4 KM AH MB RF UM BVSC SC0EUM-9 KM AH MBSC2 RF UM BVSC SC9EUM KM AH MB RF UM 1 Use a locknut for protection if a clamp mount MB...SC2 is installed. 2 Only mountable on units without button. Remove the button from the shock absorber, if there s one fitted. See page. Issue 1.1 Specifications subject to change Stoßdämpfer GmbH PO Box DE Langenfeld Tel Fax info@ace-int.eu

2 Shock Absorber Accessories M to M 2 Switch Nylon PB SP AS PS BP PP Page Thread Size Mx0. Thread Size Mx0. Thread Size Mx1 PB PB-A PB Thread Size Mx1 PB AS PS PB AS PS PBSC Thread Size Mx1 PB AS PS PB AS PS PBSC SP AS PSSC Thread Size PB SP AS PS included PB SP AS PS PP0 PBSC AS included BP PB SP AS PS Thread Size Mx1. PBSC AS included BP PB SP AS PS PP2 PBSC AS included BP PBSC AS included Issue 1.1 Specifications subject to change Thread Size Mx1. PBSC AS included BP AS included BP PB SP AS PS PP00 PBSC AS included BP PB AS included AS included BP 2 Only mountable on units without button. Remove the button from the shock absorber, if there s one fitted. See page. Dimensions see pages to. Stoßdämpfer GmbH PO Box DE Langenfeld Tel Fax info@ace-int.eu

3 Shock Absorber Accessories M to M Selection Chart See Pages to Mx0. KM 2. Mx0. AF AH Mx0. 7 MBSC2 Mx0. M Mx0. KM Mx0. AF AH Mx0. MBSC2 Mx0. M RF Mx0. Mx Mx1 KM AH MBSC2 RF Mx1 AF Mx1 M4 Mx1. M4x 1 Mx1 BV AF9 AF Mx1 BVA AF9 AF Mx1 PB PB-A Mx1 KM 4 BV Mx1 AF AH 4 Mx1. AF AF 1 Mx1. Dimensions BVSC on request PB MBSC2 M4.2 Mx1 4. PBSC RF M4x AS 17 Mx1 2 Mx1 Switch 2 2 UM Mx1 4. PS..2 Issue 1.1 Specifications subject to change Mounting, installation... see pages 7 to 9. Stoßdämpfer GmbH PO Box DE Langenfeld Tel Fax info@ace-int.eu

4 Shock Absorber Accessories M to M Selection Chart See Pages to Mx1 KM AH MB MBSC2 RF Mx1 AF Mx1 M Mx1 4. M Mx1 4. Mx Mx1 UM 4. Mx1 BV AF1 AF Mx1 7 1 BVSC AF1 AF Mx1 7 1 PB.2 2 PBSC SP AS PS PSSC Mx1 AF 19 Mx1 Switch KM AH MB MBSC2 RF 17 AF M 4. M 4. Mx 2 Issue 1.1 Specifications subject to change UM 4. 4 PBSC SP BV 1 1 AF 9. AF. AS 21 Switch 17 BVSC 1 AF PS BP PB 1 4. PP Nylon W max = Nm Mounting, installation... see pages 7 to 9. Stoßdämpfer GmbH PO Box DE Langenfeld Tel Fax info@ace-int.eu

5 Shock Absorber Accessories M to M Selection Chart See Pages to Mx1. KM AH MB MBSC2 RF Mx1., Mx1., AF M 2 40 Mx1. M 0 Mx1. 1 Mx 4 Mx1. UM BV BVSC. Mx1. AF Mx1. AF Mx1. PB PBSC SP AS PS BP PP Mx1. AF1.4 2 Mx1. Switch Nylon W max = Nm Mx1. KM AH MB MBSC2 RF Mx1. AF0 0 Mx1. M 4 Mx1. M 2 Mx1. Mx 42 2 Mx1. UM BV BVSC.. 47 PBSC Mx SP 0 0 Mx1..4 AF0 Mx1. 44 AS Mx1. Switch 2 0 AF0 Mx1. 44 PS 2.4 BP PB PP Nylon W max = Nm Issue 1.1 Specifications subject to change Mounting, installation... see pages 7 to 9. Stoßdämpfer GmbH PO Box DE Langenfeld Tel Fax info@ace-int.eu

Damao Range. Single & Double Line Pressure Regulator - 4 or 8 bar

Damao Range. Single & Double Line Pressure Regulator - 4 or 8 bar Damao Range Single & Double Line Pressure Regulator - 4 or 8 bar Single and Double line pressure regulator for double stage medical gas distribution systems. 10 to 4 bar pressure regulator for all medial

More information

3/4 MPT w/ MHT Flush & Cap (80 psi) (A2)

3/4 MPT w/ MHT Flush & Cap (80 psi) (A2) 4E PLASTIC FILTERS Debris Basin Typical Filter Components Shown 3/4 MPT w/ MHT Flush & Cap (80 psi) (A2) Note: All Plastic Filter models available drilled and tapped for 1/8 schrader valve. Contact customer

More information

Universal Gage. Multimar 844 T

Universal Gage. Multimar 844 T Universal Gage Multimar 844 T Operating Instructions 3722483 0315 Mahr GmbH Standort Esslingen Reutlinger Str. 48, 73728 Esslingen Tel. +49 711 9312-600, Fax +49 711 9312-756 mahr.es@mahr.de, www.mahr.com

More information

Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Two normally closed automatic shutoff valves in one housing.

More information

Flow control valves Series RFU - RFO 2/

Flow control valves Series RFU - RFO 2/ CATALOGUE > Release 8.5 > Valves Series RFU - RFO Flow control valves Series RFU - RFO Unidirectional and bidirectional flow control valves Ports: M5, G1/8, G1/4, G3/8 and G1/ Nominal diameter: M5 = 1,5

More information

TBi RM 50 G. RoboMIG 1.1. Technical data. Robot welding torch TBi RM 50 G

TBi RM 50 G. RoboMIG 1.1. Technical data. Robot welding torch TBi RM 50 G RoboMIG TBi RM 50 G Technical data Robot welding torch TBi RM 50 G Short gas nozzle for better accessibility Rating at 60% duty cycle (10 min. cycle) - Mixed gas: 8.8 kw (approx. 250-280 A) Cooling method

More information

ARI-DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP

ARI-DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP ARI-DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 ARI-DP32 / DP33 Pneumatic actuator Page 2 DP-Actuator Extended stem on air failure ARI-DP34 Pneumatic actuator Page 2 ARI-DP34T Pneumatic actuator Page 6

More information

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1. > Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to

More information

Description Total stroke Maximum Recommended Page in mm gripping force in N workpiece weight in kg

Description Total stroke Maximum Recommended Page in mm gripping force in N workpiece weight in kg Overview parallel gripper Description Total stroke Maximum Recommended Page in mm gripping force in N workpiece weight in kg Version 1 2 1 2 1 2 RRP-A 64 12 6 240 450 1,2 2,2 26 80 16 8 380 700 1.9 3.5

More information

Mechanical Wind Recorder

Mechanical Wind Recorder THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021186/11/06 Mechanical Wind Recorder 4.3900.20.000 ADOLF THIES GmbH & Co. KG Hauptstraße 76 37083

More information

Diaphragm Valve, Metal

Diaphragm Valve, Metal Diaphragm Valve, Metal Construction The GEMÜ pneumatically operated 2/2-way diaphragm valve has a low maintenance membrane actuator which can be controlled by inert gaseous media. Features? Suitable for

More information

Pressure regulators Manually operated Fine setting valves. Brochure

Pressure regulators Manually operated Fine setting valves. Brochure Pressure regulators Manually operated s Brochure Pressure regulators Manually operated s Qn = 9 l/min Actuating element: Push button Internal thread Poppet valve Qn = 9 l/min Actuating element: Push button

More information

Opening Angle 76º 30º [337] 45º 76º 30º [213] 45º 76º 30º [169] 45º 76º 30º [337] 45º 76º 30º [337] 45º 76º 30º [128] 45º 76º 30º [404] 45º 76º 30º

Opening Angle 76º 30º [337] 45º 76º 30º [213] 45º 76º 30º [169] 45º 76º 30º [337] 45º 76º 30º [337] 45º 76º 30º [128] 45º 76º 30º [404] 45º 76º 30º 17.22 Picture Force N [lbs] Opening Angle Weight Opening/closure time min 84A3-310000000 84A3X310000000 84A3Y310000000 84A3Z310000000 60º 1,35 84A3-0000000 84A3X0000000 950 84A3Y0000000 [213] 84A3Z0000000

More information

1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits

1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits /-Way Angle-Seat Valve Type 000 to - NPT; 0 to 30 Advantages / Benefits Spring return closed or open, double-acting Materials: bronze, stainless steel High flow rate Self-adjusting packing glands with

More information

CONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint

CONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint Super-rapid fittings for plastic tubes Series 6000 Sprint Tube external diameters: 3,, 5, 6, 8, 10, 12, 1, 16 mm Fittings threads: metric (M3, M5, M6, M7), BSP (G1/8, G1/, G3/8, G1/2, G3/), BSPT (R1/8,

More information

Gas Appliance Pressure Regulators and. Line Pressure Regulator. FRS 7../6 Series FRS 5... Series

Gas Appliance Pressure Regulators and. Line Pressure Regulator. FRS 7../6 Series FRS 5... Series Gas Appliance Pressure Regulators and Line Pressure Regulators FRS../6 Series FRS 5... Series CSA Certified ANSI Z21.18 CSA 6.3 as a Gas Appliance Pressure Regulator ANSI Z21.80 CSA 6.22 (FRS/6 series

More information

Pressure decay sensor Pressure decay sensor Flow at 90 psi (6 bars) Tripping point at 90 psi (6 bar) supply Connection Mechanical life Relay C

Pressure decay sensor Pressure decay sensor Flow at 90 psi (6 bars) Tripping point at 90 psi (6 bar) supply Connection Mechanical life Relay C Position Detectors Order/Technical Support Tel: (800) 6773 / FAX: (800) 677386 / www.crouzetusa.com / Pressure decay sensor Pressure decay sensor 8 04 02 Flow at 90 psi (6 bars) Tripping point at 90 psi

More information

// ADapters GUIDelines

// ADapters GUIDelines // ADapters GUIDelines ADAPTER SELECTION Selection of an appropriate ALFAGOMMA adapter for a given application depends on the fluid system operating parameters listed below and the tube material and wall

More information

Easy to operate even for biginners. Set up the number of test. Possible to select from 1 to times

Easy to operate even for biginners. Set up the number of test. Possible to select from 1 to times With a force gauge and attachments, compression/tensile/peeling tests are possible up to 1000N/2500N. It provides consistent testing speed and direction, offering highly accurate test results. MX2-2500N

More information

THE EXPERT IN LEVEL AND FLOW

THE EXPERT IN LEVEL AND FLOW Magnetic Multi-Float-Switch Type: ITA-T1R Technical Information 01/2018 THE EXPERT IN LEVEL AND FLOW LEVEL ITA-T1R Technical Information Intra-Automation Intra-Automation Technical Information 01/2018

More information

Meta-MEC Manual Motor Starters

Meta-MEC Manual Motor Starters www.lsis.biz Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LS Meta-MEC Manual Motor Starters deliver more

More information

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

SV - Safety Shutoff Valve with Proof of Closure 1/2 NPT - 2 NPT. SV/614 Series SV-DLE/614 Series SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT SV/614 Series SV-DLE/614 Series Normally closed automatic shutoff valve with proof of closure and the following approvals. CSA Certified

More information

Pressure maintenance valve SDV-P / SDV-P-E

Pressure maintenance valve SDV-P / SDV-P-E Translation of the original manual Pressure maintenance valve SDV-P / SDV-P-E Assembly and Operating Manual Superior Clamping and Gripping Imprint Imprint Copyright: This manual remains the copyrighted

More information

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid R133 Brass high pressure regulator, suitable for compressed air, gas and liquid HELYON 5 Chemin du Jubin 6957 DARDILLY Tél. +33 () 7 5 16 7 - Fax +33 () 7 5 16 71 FEATURES High pressure regulator for cylinder

More information

3-Way Safety Block DSV

3-Way Safety Block DSV 3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with

More information

RL2 AA 247 AA 246 RL2. Standard type Standard type Switch Set. type. With guide. With guide Type. Standard type. Model.

RL2 AA 247 AA 246 RL2. Standard type Standard type Switch Set. type. With guide. With guide Type. Standard type. Model. 26 27 Model Standard type With guide Type Standard type Standard type Switch Set Cylinder bore (mm) 2532 Working fluid Air Lubrication Unnecessary (Cylinders with strokes of mm or more must be lubricated.)

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

Note: the lock-out circuit must be in accordance with Section 8.7 of DIN/VDE Twin thermostats ATH.-SW-2020 ATH.-SW-2070 ATH.

Note: the lock-out circuit must be in accordance with Section 8.7 of DIN/VDE Twin thermostats ATH.-SW-2020 ATH.-SW-2070 ATH. M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 3603 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-60 E-mail: mail@jumo.net Internet: www.jumo.net

More information

Easy to operate. Wide space

Easy to operate. Wide space With a force gauge and attachments, compression/tensile/pealing tests are possible up to 1000N/2500N. It provides consistent testing speed and direction, offering highly accurate test results. MX2-2500N

More information

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES P0170E-1.DOCX/08.16/MG CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES With a Central Gas Supply System, individual work places or gas take-off stations are supplied with gas through

More information

ComEx Actuating elements

ComEx Actuating elements ComEx Actuating elements for Zone and 2 ComEx Actuating elements Features Easy installation Certified for Zone and 2 High IP degree of protection A large number of variants and versions of actuating elements

More information

L3 Pressure and Level transmitter

L3 Pressure and Level transmitter SENSORS FOR AND BIOPHARMA. Product Information L3 L3 Pressure and Level transmitter Range of applications Hydrostatic Level measurement in dynamic temperature environments Pressure measurement in pipes

More information

TeSys protection components

TeSys protection components Presentation, description -pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively

More information

Level 1. Certificate of Conformity. Australian Certification Services Pty Ltd grants to the WaterMark User: Uponor GmbH. Trading as UPONOR Q & E

Level 1. Certificate of Conformity. Australian Certification Services Pty Ltd grants to the WaterMark User: Uponor GmbH. Trading as UPONOR Q & E Level 1 Certificate of Conformity Australian Certification Services Pty Ltd grants to the WaterMark User: Uponor GmbH Trading as UPONOR Q & E the right to use the WaterMark as shown above in conjunction

More information

Instructions Manual. Variable area flowmeter 60 M-1. Series. instrumentation for fluids. Technical Data. C-MI-60M1 Rev.: 0 English Version

Instructions Manual. Variable area flowmeter 60 M-1. Series. instrumentation for fluids. Technical Data. C-MI-60M1 Rev.: 0 English Version instrumentation for fluids Variable area flowmeter Series 60 M-1 Instructions Manual Technical Data Accuracy: ± 2,5% of full scale value. Based on VDE/VDI 3513 Scales: In l/h, l/min, m³/h, kg/h, %, mm.,

More information

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm Inductive Linear Displacement Transducers Model IW 260 Measuring strokes 80, 170, 240, 360 Document no. IW 100 HE Date 1.07.201 Contactless, robust sensor system Infinite resolution, no hysteresis Calibrated

More information

Shock absorbers Series MC-SC. Catalogue : PDE2524TCUK-ab

Shock absorbers Series MC-SC. Catalogue : PDE2524TCUK-ab Series Catalogue : PE2524TCUK-ab WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PROUCTS AN/OR SYSTEMS ESCRIE HEREIN OR RELATE ITEMS CAN CAUSE EATH, PERSONAL INJURY AN PROPERTY AMAGE. This

More information

Bike holder with three-point-support for mounting stand

Bike holder with three-point-support for mounting stand Bike holder with three-point-support for mounting stand Ref.no. 589 4726 Translation of the original manual Issued: 07 / 2010 Keep this manual for future reference! Manufacturer: Weilnhammer Maschinenbau

More information

Valves, manually operated

Valves, manually operated Valves, manually operated Valves, manually operated Key features VHEM-P K/O-3-PK-3 H-3-¼-B KH/O-3-PK3 TH/O-3-PK3 F-3-¼-B Innovative Versatile Reliable Easy to mount Small and compact for a wide range of

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 2400 N 2400.15 ST.9 E Concept The diaphragm pumps from KNF arebased on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its

More information

Actuating elements for ComEx

Actuating elements for ComEx Description A large number of variants and versions of actuating elements are available for the ComEx control and indicator units. All actuating elements are made of high-quality thermoplastic and conform

More information

Armatures for analytical probes

Armatures for analytical probes Armatures for analytical probes For many different types of installations and applications Large range of probe holders General purpose, water treatment, food & beverage, pharmaceutical applications Type

More information

Local Solutions For Individual Customers Worldwide. Pressure Transmitter and Reader of the PT-RF Series. Product Catalogue

Local Solutions For Individual Customers Worldwide. Pressure Transmitter and Reader of the PT-RF Series. Product Catalogue Local Solutions For Individual Customers Worldwide Pressure Transmitter and Reader of the PT-RF Series Product Catalogue Series PT-RF Pressure Transmitter and Reader of the Series PT-RF Originating and

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Galvanized steel flanges

Size : Ends : Min Temperature : Max Temperature : Materials : Galvanized steel flanges Size : Ends : Min Temperature : Max Temperature : DN 32 to 600 Flanges ISO PN10/16-10 C + 100 C for EPDM and + 80 C for NBR Max Pressure : 16 Bars up to DN 300 Specifications : Absorb vibrations and noises

More information

F series Foot Switches

F series Foot Switches F series Foot Switches ITC presents a complete line of foot switches from Bernstein, designed to respond to the most stringent requirements for machine control and safety applications. The F series includes

More information

Valves, manually operated

Valves, manually operated Valves, manually operated Valves, manually operated Key features VHEM-P K/O-3-PK-3 H-3-¼-B KH/O-3-PK3 TH/O-3-PK3 VHEM-L F-3-¼-B Innovative Versatile Reliable Easy to mount Small and compact for a wide

More information

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Technical data sheet. Type overview. Technical data. Safety notes.   T5-R2.. Open-close en v Subject to changes 1 / 3 Technical data sheet R2.. Open-close ball valves, 2-way, with internal thread for open and closed cold and warm water systems for shut-off functions on the water side and 2-point controls in air-handling

More information

Gas Filters DN15 DN300. delta-elektrogas.com EE151 03/17

Gas Filters DN15 DN300. delta-elektrogas.com EE151 03/17 FG Gas Filters DN15 DN300 delta-elektrogas.com EE151 03/17 FG Gas Filters Contents Description.. 2 Features.. 2 Functioning and application. 3 Technical specifications 4 Gas flow chart (pressure drop)

More information

Instruction Manual Differential Pressure Transmitter

Instruction Manual Differential Pressure Transmitter DE61 Instruction Manual Differential Pressure Transmitter Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information

F Fittings with 24 cone as per DIN EN ISO Fitting accessories, plug-type connectors, hydraulic pipes, pipe clamps, pressure gauges

F Fittings with 24 cone as per DIN EN ISO Fitting accessories, plug-type connectors, hydraulic pipes, pipe clamps, pressure gauges Fittings with 24 cone as per DIN EN ISO 8434-1 Fitting accessories, plug-type connectors, hydraulic pipes, pipe clamps, pressure gauges Issue 8-17 E F 9.300 Advantages NNWorldwide spread high-pressure

More information

Safety Shut-Off Valve RMG 711

Safety Shut-Off Valve RMG 711 Safety Shut-Off Valve RMG 711 Product information serving the gas industry worldwide Application, Features, Technical Data Application safety device for gas pressure regulating stations suitable for natural

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 143 N 143 SP.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central

More information

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604 Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604 Two normally closed safety shutoff valves in one housing; each with the following approval. CSA Certified ANSI Z21.21

More information

RTA Series 1 4 Poles Coded Rotary Switches

RTA Series 1 4 Poles Coded Rotary Switches 1 4 Poles oded Switches Features/Benefits PB or hand soldering versions Bushing mounting Multiple poles Decimal and hexadecimal codes Screwdriver slot or extended actuator RoHS ompliant Typical Applications

More information

Compact Ejectors. Compact Ejectors SCPi / SMPi Suction rate from 75 l/min to 185 l/min

Compact Ejectors. Compact Ejectors SCPi / SMPi Suction rate from 75 l/min to 185 l/min Compact Ejectors Suitability for Industry-Specific Applications Applications Handling of air-tight as well as porous workpieces supply and vacuum monitoring in automated systems For use in sheet metal

More information

Modular Air Combination Units

Modular Air Combination Units ...... 12-25 NAC1 ~ 6 series.................................. 12-16 Filter + Regulator + Lubricator NAC11 ~ 41 series.................................. 17-18 Filter/Regulator + Lubricator NAC12 ~ 62 series..................................

More information

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express AIR DRIVEN Gas Boosters & SYSTEMS Accepting VISA, MasterCard and American Express Gas Boosters AIR DRIVEN FROM 30 PSI TO 21,750 PSI MAXIMATOR Maximator gas boosters are an excellent alternative to high

More information

Certified Accuracy. Ring Force Gauge. Models and Capacities Available. Design and Principle of Operation

Certified Accuracy. Ring Force Gauge. Models and Capacities Available. Design and Principle of Operation Certified Accuracy Ring Force Gauge The accurate measurement of mechanical forces is required in hundreds of applications from a simple weighing procedure to the calibration of testing machines and load

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION Model No. Description RP2300FC, RP2301FC Router CONCEPT AND MAIN APPLICATIONS Models RP2300FC and RP2301FC are upgraded sister tools of our current plunge-type electronic router Model

More information

Industrial Products Catalog Tank Valves

Industrial Products Catalog Tank Valves Industrial Products Catalog Tank Valves Schrader International core competencies include high volume precision machining, assembly and testing of fluid control devices. Since developing the first pneumatic

More information

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Two normally closed automatic shutoff valves in one housing.

More information

EX-RECESSED CEILING LIGHT FITTINGS

EX-RECESSED CEILING LIGHT FITTINGS EX-RECESSED CEILING LIGHT FITTINGS RLF/RLF-INOX 250 18-58 W / RLF/RLF-INOX 250... N 18-36 W Metallic design for Zone 1 and Zone 21 The RLF... explosion-protected recessed ceiling light fittings with electronic

More information

Protection System AS-D

Protection System AS-D Protection System AS-D The safe protection against falling door systems and guards 1 D O O R S + FA Ç A D E S Field-proven Safety Technology Protection System AS-D Approved Safety - Universally Applied

More information

runner systems. At present, this feature is available for the Gacela (roller) runner systems, Cisne (ball bearing) runner systems,

runner systems. At present, this feature is available for the Gacela (roller) runner systems, Cisne (ball bearing) runner systems, F U R N I T U R E F I T T I N G S M A N U F A C TU R E R gradual closing Indamatic can now also be applied as an option to the more economical drawer and runner systems. At present, this feature is available

More information

Hydraulic Damper (HB) 07/2011

Hydraulic Damper (HB) 07/2011 e l b a t adjus Hydraulic Damper (HB) EL2 = 2x + 40 M5x5 Ø15 Ø6 M5x5 Size 6/15 : (Extension and compression force 20N to 800N) size EL1 V0 V0 A 6 100 240* V0 = Thread V0 = Thread 6 = 6/15 25 90* S2 = S2

More information

CLIMBING PROTECTION SYSTEM AL2 INSTALLATION GUIDE SYSTEM AL2

CLIMBING PROTECTION SYSTEM AL2 INSTALLATION GUIDE SYSTEM AL2 CLIMBING 0158 INSTALLATION GUIDE INSTALLATION GUIDE 0158 CLIMBING Climbing protection ladders / Climbing protection rail system FABA AL2 The climbing protection system is designed in accordance with EN

More information

Operating Instructions

Operating Instructions Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table

More information

CO2 Tank Conversion Kit P.N , P.N , and P.N

CO2 Tank Conversion Kit P.N , P.N , and P.N Foodservice Group Multiplex Beverage Equipment Installation Instructions for CO2 Tank Conversion Kit P.N. 002247, P.N. 0022505, and P.N. 0025099 Introduction The following instructions cover the installation

More information

Introduction INDEX. INTRODUCTION HSE

Introduction INDEX.  INTRODUCTION HSE Introduction INDEX SECTION PAGE INTRODUCTION ORDERING CODE GLOSSARY MOTOR OPTION TECHNICAL SE SE3 / SE5 SE7 / S7 SE9 / S9 SE12 / S12 SE14 / S14 SE14-2 / S14-2 SE17 / S17 SE17-2 / S17-2 SE21 / S21 SE21-2

More information

Airfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E

Airfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E AIRFIX EXPANSION VESSELS Flamco Airfix Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX AIRFIX -E Flamco Edition 2005 / EXP Flamco Flamco offers you a wide choice

More information

UCA2 Series. Bore size: 10, 16, 25, 32. UCA2 UCA2-L (with switch) Double acting Compressed air to 60 (no freezing)

UCA2 Series. Bore size: 10, 16, 25, 32. UCA2 UCA2-L (with switch) Double acting Compressed air to 60 (no freezing) SCP* CMK CM SC CKV C/OV CT MDC SMD JSK/M U STR SRL SM RCC Specifications Descriptions Bore size mm ctuation Working fluid Max. working pressure MPa Min. working pressure MPa Withstanding pressure MPa mbient

More information

DIRECTIONS OF USE. Version for printout TITAN 3 TITAN 6. Rößler Waffen GmbH

DIRECTIONS OF USE. Version for printout TITAN 3 TITAN 6. Rößler Waffen GmbH DIRECTIONS OF USE Version for printout TITAN 3 TITAN 6 Rößler Waffen GmbH Ing. Walther Simmer-Weg 11 A-6330 Kufstein Tel.: +43 (0) 5372 90810 Fax: +43 (0) 5372 90811 office@jagd-shop.at www.jagd-shop.at

More information

Operating Instructions for Flow Restrictors. Model: REG

Operating Instructions for Flow Restrictors. Model: REG Operating Instructions for Flow Restrictors Model: REG 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...

More information

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version 2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version Type 6624 Impulse can be combined with... 10mm width orifice DN 0.8 to 1.2 with pressure range vacuum to 5bar medium separation, for

More information

TECHNICAL SPECIFICATIONS CHASSIS» 76

TECHNICAL SPECIFICATIONS CHASSIS» 76 TECHNICAL SPECIFICATIONS CHASSIS» 76 CHASSIS 690 SUPERMOTO 2007 690 SUPERMOTO PRESTIGE 2007 Frame Fork Spring travel front Rear suspension Spring travel rear Front brake Rear brake Chromoly trellis frame,

More information

TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads

TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads TBV-CM Combined control & balancing valves for small terminal units For modulating control NPT threads IMI TA / Control valves / TBV-CM TBV-CM Designed for use in terminal units in heating and cooling

More information

Fuel Filters DN15 DN25. elektrogas.com DE

Fuel Filters DN15 DN25. elektrogas.com DE FF Fuel Filters DN15 DN25 elektrogas.com DE180 0914 FF Fuel Filters Contents Description.. 2 Features.. 2 Functioning and application. 3 Accessories and optionals 4 Technical specifications 4 Gas flow

More information

Pressure Switch for gas and air

Pressure Switch for gas and air Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. 13 and No. 0 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth

More information

SLEEVE AND COLLAR MOUNT FREESTALLS

SLEEVE AND COLLAR MOUNT FREESTALLS SLEEVE AND COLLAR MOUNT FREESTALLS FREESTALLS-1 FEATURES Hot dipped galvanized or pre-galvanized loop option. Heavy galvanized 3 1/2 post Easy installation Adjustable height Cow friendly loop profile to

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

OUTER RACE SHIM SPACERS METRIC OUTER RACE SHIM SPACERS. All Dimensions in Millimeters. Material:300 Series Stainless Steel

OUTER RACE SHIM SPACERS METRIC OUTER RACE SHIM SPACERS. All Dimensions in Millimeters. Material:300 Series Stainless Steel OUTER RACE SHIM SPACERS Material:300 Series Stainless Steel METRIC OUTER RACE SHIM SPACERS All Dimensions in Millimeters Material:300 Series Stainless Steel 6-16 INNER RACE SHAFT SPACERS 3 /32" To 1 /2"

More information

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series Gas Appliance Pressure Regulators with integrated gas filter FRI/6 Series CSA Certified ANSI Z21.18 / CSA 6.3 Gas Appliance Pressure Regulator File # 1135455 EU Gas Appliance Directive EN 88 CE-0087 AU

More information

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series Dual Modular Safety Shutoff Valves DMV-D/11 Series DMV-DLE/11 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked

More information

GB Full-lift safety valves with additional loading type PV 1509

GB Full-lift safety valves with additional loading type PV 1509 0-07. 09.1.GB Full-lift safety valves with additional loading type PV 1509-1- PV 1509 Full-lift safety valves with additional loading DN 65 x 100 to 50 x 600 Application The full-lift safety valve with

More information

TECHNICAL DATA - CHASSIS 179

TECHNICAL DATA - CHASSIS 179 TECHNICAL DATA - CHASSIS 179 Frame Fork Shock absorber Suspension travel (Supermoto) Front Rear Suspension travel (Supermoto R, Supermoto T) Front Rear Brake system Front Rear Brake discs - diameter Front

More information

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Pressure relief valve DHV 725 set range: 0,2-10,0 bar Pressure relief valve DHV 75 set range: 0, - 0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level

More information

Pull-rope emergency stop switch Type HENEX and SEGEX OPERATING INSTRUCTIONS

Pull-rope emergency stop switch Type HENEX and SEGEX OPERATING INSTRUCTIONS Pull-rope emergency stop switch Type OPERATING INSTRUCTIONS Legal Notice (Translation of the original) Document No.: 94.058 816.191 Pull-rope emergency stop switch, Type HENEX and SEGEX Product number:

More information

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series Gas Appliance Pressure Regulators with integrated gas filter FRI/6 Series CSA Certified ANSI Z21.18 / CSA 6.3 Gas Appliance Pressure Regulator File # 1135455 EU Gas Appliance Directive EN 88 CE-0087 AU

More information

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691 THE BP-690 SERIES Operating and Service Manual Series includes all variants of BP-LF/MF-690/691 Issue B April 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special

More information

ASB Accumulator Safety Blocks

ASB Accumulator Safety Blocks ASB Accumulator Safety Blocks For working pressures up to 350 bar Catalogue HY07-1241/UK Note: In line with our policy of continuing product improvement, specifications in this catalogue are subject to

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or user units. It complies with the relevant safety standards in accordance with

More information

57 Series Pg Pg Pg Pg Pg Pg Pg Pg Pg. 2.

57 Series Pg Pg Pg Pg Pg Pg Pg Pg Pg. 2. 57000 Pg. 2.5 57010 Pg. 2.5 57110 Pg. 2.5 57210 Pg. 2.5 57222 Pg. 2.6 57020 Pg. 2.6 57010 Pg. 2.6 57030 Pg. 2.6 57105 Pg. 2.7 57115 Pg. 2.7 57125 Pg. 2.7 57215 Pg. 2.8 57225 Pg. 2.8 57100 Pg. 2.8 57200

More information

Hand lever valves VHER

Hand lever valves VHER Hand lever valves VHER Hand lever valves VHER Key features Powerful Flexible Practical -M- Flow 170 3800 l/min 4/3-way valve mid-position closed mid-position exhausted mid-position pressurised Connections:

More information

GOST R CERTIFICATION SYSTEM FEDERAL AGENCY OF TECHNICAL REGULATION AND METROLOGY CERTIFICATE OF CONFORMITY

GOST R CERTIFICATION SYSTEM FEDERAL AGENCY OF TECHNICAL REGULATION AND METROLOGY CERTIFICATE OF CONFORMITY CERTIFICATE OF CONFORMITY No. ROSS US.GB05.V03061 Valid from 8/12/2010 through 8/12/2013 No. 0422555 CERTIFICATION AGENCY ROSS RU.0001.11GB05 NONPROFIT INDEPENDENT RESEARCH ORGANIZATION (), CERTIFICATION

More information

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I

More information

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min Pressure Filters D D 6 In-line mounting Operating pressure up to 1 bar Nominal flow rate up to 9 l/min Description Application In the pressure circuits of hydraulic and lubrication systems. Performance

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 9 S E R I E S Electropneumatically and pneumatically operated valves Series 9 Assembly with sub-base (ISO 5599/1 Standards) Sizes 1, 2 and 3 The Series 9 electropneumatically or pneumatically operated

More information

vacon nx ac drives hxl040 cooling unit, ss-piping commissioning and maintenance manual

vacon nx ac drives hxl040 cooling unit, ss-piping commissioning and maintenance manual vacon nx ac drives hxl040 cooling unit, ss-piping commissioning and maintenance manual WARNING HOT SURFACE! NOTE WARNING HOT SURFACE! NOTE 11571_uk WARNING ! NOTE! NOTE WARNING! NOTE Additional

More information

Radiator valves VDN1.. VEN1..

Radiator valves VDN1.. VEN1.. 2 105 EN 215 Straight valves VDN1.. Angle valves VEN1.. ACVATIX TM Radiator valves VDN1.. VEN1.. DIN-norm, for 2-pipe heating systems Valve bodies made of brass, mat nickel-plated DN 10, DN 15 and DN 20

More information

vacon nx ac drives hxm120 cooling unit, ss-piping commissioning and maintenance manual

vacon nx ac drives hxm120 cooling unit, ss-piping commissioning and maintenance manual vacon nx ac drives hxm120 cooling unit, ss-piping commissioning and maintenance manual WARNING HOT SURFACE! NOTE WARNING HOT SURFACE! NOTE 11571_uk WARNING ! NOTE! NOTE WARNING! NOTE Secondary

More information