Hydraulic Damper (HB) 07/2011
|
|
- Ilene Watts
- 5 years ago
- Views:
Transcription
1 e l b a t adjus Hydraulic Damper (HB)
2 EL2 = 2x + 40 M5x5 Ø15 Ø6 M5x5 Size 6/15 : (Extension and compression force 20N to 800N) size EL1 V0 V0 A * V0 = Thread V0 = Thread 6 = 6/ * S2 = S2 = * B3 = B3 = * G5 = G5 = * 350 N R7 = R7 = 340* 300 N J3 = Ball socket J3 = Ball socket S2 Technical advices: * the length of chosen s has to be added EL1 = EL2 + s B3 G5 R7 Ball socket J3 force = 50N. Please indicate in case of an order. EL2 = 2.45 x + 47 Chosen s have to be secured
3 EL2 = 2x + 50 M8x8 Ø22 Ø8 M8x9 Size 8/22 : (Extension and compression force 30N to 1.800N) B0 N0 A * size EL1 B0 = Thread N0 = Thread 1 = 8/22 50 * S3 = S3 = * A3 = A3 = 350* C5 = C5 = * N 1. A7 = A7 = * N 1. S3 Technical advices: * the length of chosen connecting parts has to be added EL1 = EL2 + s A3 C5 A7 Ball socket P3 force = 100N. Please indicate in case of an order. EL2 = 2.38 x + 55 Chosen s have to be secured
4 EL2 = 2x + 60 M8x8 Ø28 Ø10 M8x9 Size 10/28 : (Extension and compression force 30N to 3.000N) H0 N0 A * size EL1 H0 = Thread S3 = A3 = C5 = A7 = N0 = Thread S3 = A3 = C5 = A7 = 3 = 10/ * 360* 460* 560* 660* 760* 860* 1060* N N N N S3 Technical advices: * the length of chosen s has to be added EL1 = EL2 + s A3 C5 A7 Ball socket P3 force = 100N. Please indicate in case of an order. EL2 = 2.35 x + 60 Chosen s have to be secured
5 EL2 = 2x + 75 MF14x15 Ø40 Ø14 MF14x15 Size 14/40 : (Extension and compression force 30N to N) Z0 Z0 A B * size EL1 Z0 = Thread S5 = B4 = L5 = C8 = Z0 = Thread S5 = B4 = L5 = C8 = B = 14/ * 375* 475* 675* 875* 1.075* 1.275* 1.475* 1.675* N N N * the length of chosen s has to be added EL1 = EL2 + s S5 B4 L5 C8 Technische Hinweise: force = 200N. Please indicate in case of an order. EL2 = 2.32 x + 82 Chosen s have to be secured
6 Hydraulic damper (HB) Technical advices / installation recommendations To consider: The maximum loads and pull direction may not be exceeded. There must be a mechanical limit stop approx. 1-2 mm before end of. Mounting of the dampers is in any position possible. The s should be secured against rotation. Due to constructional reasons, Type has a free travel of approx. 20 % For a function without free travel, Type has to be chosen. Adjustment of the dampers: - An adjustment is only possible in completely inserted or extended position - The force can be adjusted by turning the piston as described below. Thereby, the length EL2 will be extended by max. 6 mm. Please take care during the adjustment that you don't damage the adjustment segment by turning it too strong against the limit stop. In case of considerable resistance, please stop the adjustment. The dampers of Type can be adjusted either in completely inserted or extended position. The dampers of Type can be adjusted in completely extended position. 1. Hold the. 2. Adjust the damper by turning the. In case of adjustment with extended, please pull the slightly during the turning process until the piston locks. In case of adjustment with inserted, the has to be pushed slightly until it locks. Turning to the right: Damping will be increased, speed will be reduced Turning to the left: Damping will be reduced, speed will be increased
DICTATOR "DIREKT" Gate Closer
DICTATOR "DIREKT" Gate Closer For Access Gates in Boundary Fences The DICTATOR gate closer DIREKT is the economic solution for the reliable and controlled closing of outside gates, such as admission gates
More informationDICTATOR "DIREKT" Gate Closer
DICTATOR "DIREKT" Gate Closer For Access Gates in Boundary Fences The DICTATOR gate closer DIREKT is the economic solution for the controlled closing of outside gates, such as admission gates to kinder
More informationSplitting cylinder C20
Splitting cylinder C20 Product abbreviation C20 HN C20 = Size of splitting cylinder N or L = Wedge set length H / V / J / C = Mounting version Purpose of application Horizontal splitting (+/- 45 to the
More informationCost effective. Smooth. Reliable. LOG Internal Hole Gripper
LOG Cost effective. Smooth. Reliable. LOG Internal Hole Gripper Light gripper made of very resistant polyamide with closed diaphragm system Field of Application Particularly suited to highly dynamic applications
More informationWide opening parallel grippers Series CGLN
CATALOGUE > s 202 Wide opening parallel grippers Series CGLN > Grippers Series CGLN Magnetic Sizes: ø 0-6 - 20-25 - 32 mm» High flexibility during mounting» High grip force» Rack and pinion synchronized
More informationACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS
ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS READ ALL INSTRUCTIONS PRIOR TO INSTALLATION AND OPERATION TO AVOID POSSIBLE INJURY Warning: Always consider any accumulator to contain pressure until proven
More informationSupplementary instructions. Rod and cable components. for VEGAFLEX series 80. Document ID: 44968
Supplementary instructions Rod and cable components for VEGAFEX series 80 Document ID: 44968 Contents Contents 1 Product description 1.1 Extensions... 3 2 Mounting 2.1 General instructions... 6 2.2 Rod
More informationCylinder Controls. Operating information. For ATEX specific products contact Sales Office. 2/2 Blockers. PDE2600PNUK Parker Pneumatic
A range of speed controls, flow controls and back pressure sensors designed to be mounted directly onto the cylinder in the optimum position for maximum performance. "Push-in" or threaded connection Multifunction
More informationTechnical Data Sheet TI-F50 Locking Units series KFH
English translation of German original Locking Units series KF Further important practical advice is given in Operating Manual BA-F50., Rod diameter 18 mm 50 mm øz 8 L 2 6 x 6 0 min. 4x30 KF 18 to KF 32,
More informationPressure regulator for water
Pressure regulator for water rass version with VGW and international drinking water approvals Stainless steel version with VGW approval Compact plastic version Manometer port at pressure output The water
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationK0709 Quick-fit couplings
Joints 1067 K0709 Quick-fit couplings with radial offset compensation external thread D1 SW SW1 application example: X max. D D 3 4 internal thread SW 3 4 2 SW1 D D Coupling part and claw in steel. Nut
More informationPressure regulators Manually operated Fine setting valves. Brochure
Pressure regulators Manually operated s Brochure Pressure regulators Manually operated s Qn = 9 l/min Actuating element: Push button Internal thread Poppet valve Qn = 9 l/min Actuating element: Push button
More informationTANDEM plus BLUMOTION 563H/563. installation instructions
56H/56. installation instructions inside Full extension concealed runners Basic components ocking devices New side adjustment New rear side adjustment otate side adjustment left or right equally on both
More informationLeak-Free Load-Control Valve SAE ½ psi flange
Leak-Free Load-Control Valve SE ½ - 6000 psi flange Q max = 150 l/min [40 gpm], p max = 420 bar [6000 psi] leak-proof, two-stage hydraulic, SE-flange design 12--S... 1 Description Two-stage load-control
More informationFixed Displacement Plug-In Motor A2FE
www.phphyds.com Series 6, axial tapered piston, bent axis design for mounting in mechanical gearboxes Sizes 28...355 Nom. Pressure up to 400 bar Peak Pressure up to 450 bar he fixed displacement plug-in
More informationBUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-
BUTTERFLY VALVES 1. General HyrdoWer is a globally recognized manufacturer of power unit accessories. They have become specialists in the design of Butterfly Valves and Hydraulic Compensators. The shut
More informationPRO1030 Bi-Directional Assembly Replacement
PRO1030 Bi-Directional Assembly Replacement 1. Remove both side covers using the Crank and Cover Removal procedure. Fig. 1 2. Disconnect both brake cables (not shown) from the brake (S3611). (Fig. 1) 3.
More informationComponents for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.
Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using
More informationDifferential pressure control and flow limiter AVPB/AVPB-F, PN 16
Data sheet Differential pressure control and flow limiter AVPB/AVPB-F, PN 16 Application AVPB is a self-acting differential pressure control and flow limiter primarily for use in district heating systems.
More information09 - Choosing /sizing a cylinder and valve
- Choosing /sizing a cylinder and valve - Pipe flow resistence - Valve sizing - Cylinder sizing LII PIPE FLOW RESISTENCE Flow rate Qn Flow rate is calculated as the volume at normal conditions ( atmospheric
More informationCalibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New
> Series MD regulators Series MD pressure regulators New Ports with interchangeable cartridges: threaded (1/8, 1/4, /8) or integrated with super-rapid fitting for tube with Ø 6, 8 and 10 mm Versions: single,
More informationTBV-CM. Combined control & balancing valves for small terminal units For modulating control
TBV-CM Combined control & balancing valves for small terminal units For modulating control IMI TA / Control valves / TBV-CM TBV-CM Designed for use in terminal units in heating and cooling systems, the
More informationDescription Supply pressure Pressure range Connection Device Page max. bar bar thread
Pressure Regulators Supply pressure Pressure range onnection Device Page max. bar bar thread Maxi -Series, robust, interlockable 1 0. 1.8 / 17 G¼ - G1 R0, R1.0 made of plastic, also for liquids 1,5 0 4
More informationINDUSTRIAL PNEUMATICS - air treatment units. FIL filter
Due to its metal construction, the entire range of NEW DEAL elements is resistant to heavy duty working conditions. Designed for high pressure application (up to 18 bar). FIL filter Degree of filtration:
More informationPressure Dump Valve Service Kit for Series 2300 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit
More informationBores: ø 10, 16, 20, 25, 32 mm
> Series CGLN wide opening parallel grippers CATALOGUE > Release 8.8 Series CGLN wide opening parallel grippers New version Bores: ø 0, 6, 20, 25, 32 mm»» High installation versatility»» Rack and pinion
More informationGENUINE CARGO NET INSTALLATION AND USER S INSTRUCTIONS
GENUINE CARGO NET INSTALLATION AND USER S INSTRUCTIONS Thank you for purchasing a genuine Mazda accessory. Before removal and installation, be sure to thoroughly read these instructions. Please read the
More informationFilter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with pressure gauge suitable for ATEX
Filter regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with gauge suitable for ATEX 1 00119372 Version Parts Mounting orientation Working min./max. Medium Medium temperature
More informationOPTIPOW 105 OPTIPOW 105 ; MAIN PARTS. Our Ref: PSE, Bernt Andersson
Page 1 (6) Our Ref: PSE, Bernt Andersson OPTIPOW 105 OPTIPOW 105, the compact pulse valve for the Optipulse fabric filters of different types: is a result of many years of experiences within the fabric
More informationFixed Displacement Motor A4FM
Fixed Displacement Motor 4FM RE 91 12/4. replaces: 3.95 and RE 91 1 for open and closed circuits Sizes 22...5 Series 1, Series 3 Nominal pressure up to bar Peak pressure up to 45 bar Index Features 1 Ordering
More informationTapped Hole (.375) Tapped hole 15 (.594) (.391±.004) Frame 19±0.2 (.750±.008) 12.7±0.2 (.500±.008) 19±0.2 (.750±.008) R S 4 x Ø 5.4 (.
434 Lift-off In-line Zinc can also be 31.5 19.1 (.750) For Lift-Off For on Lift-Off 1300 (300 lbf) 2200 (500 lbf) 56 T.P.I. (2.21) 31.5 19.1 (.750) Tapped hole Ø 9.5 (.375) ultimate 3300 (750 lbf) 9300
More informationControllers DR, DP, FR and DFR
Controllers DR, DP, FR and DFR RE 9060 Edition: 04.014 Replaces: 10.006 For variable pump A4VSO series 1 and 3 Open circuit Features Control of pressure and flow Remote controlled optional Pressure controller
More informationLeak free Pipe Rupture Valve for Excavators
Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................
More informationPressure Dump Valve Service Kit for Series 3000 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 000 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00, 400, 500, and 700 applicator
More informationCompact Pressure Switch
Compact Pressure Switch Series ZSE1 (For Vacuum)/SE1 (For Positive Pressure) For General Pneumatics Can be integrated with ZM ejector system. RoS Variable hysteresis 1 to 10% of set pressure (Variable)
More informationAuxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998
Auxiliary valve Sequence valve, 3-way Catalogue 9129 8542-02 (GB) 9129 8542-06 (US) October 1998 Sequence valve, 3-way Applications The sequence valve is designed to open or close a hydraulic pilot signal
More informationExpansion Thermometers Stainless Steel Series, Model 70
Mechanical Temperature Measurement Expansion Thermometers Stainless Steel Series, Model 70 WIKA Data Sheet TM 81.01 Applications General-purpose temperature measuring instruments for gaseous, liquid and
More informationNautique Triton Clamping Board Rack V2
w w w.ro swe l l marine.co m Nautique Triton Clamping Board Rack V2 Installation & Usage Instructions Part # C917-180045 Information: info@roswellmarine.com If you have any questions please call : 1-21-68-11
More informationAccessories for Progressive Systems
1-0107-6-EN Accessories for rogressive Systems Cycle switches, cycle indicators, crossporting bars, overpressure indicators, spray nozzles rogressive feeder with cycle switch Electric overpressure indicator
More informationChuck Size. Chuck Model. Chuck Dia. 5 N N N N N
CHUCK JAWS MACHINE VISES N-200A SERIES CHUCKS-3 JAW 1.5mm x 60 Serrations Power s With Adaptor Plate IN THIS SECTION: CNC Lathe s...66-72 Hydraulic s...73 Manual/Scroll s...74-86 Collet s...87-92 Live
More informationVariable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design
Brueninghaus Hydromatik Series 1, for open circuits Axial piston - swashplate design, Back to back - design RE 93100/02.97 Sizes 60...260 Nominal Pressure up to 350 bar Peak Pressure up to 400 bar Preliminary
More informationMicro grippers HGPM/HGWM
HGPM/HGWM Miniaturised and optimised for assembly tasks Versatile 2004/10 Subject to change Products 2004/2005 1 / 1 HGPM/HGWM Key features HGWM HGPM 1 2 3 4 1 2 3 4 System product for handling and assembly
More informationOperating instruction for the quick-change tap holders type:
type: HF 20 HF 30 Date of edition: 15.07.2008 Stage of alteration: 4 Please keep this for future use! Contents: 1 Application range, safety instructions and technical data... 3 1.1 Application range,
More informationBladder Accumulators High pressure
Bladder Accumulators High pressure 1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas (nitrogen) is utilised in
More informationModel A Sleeve Valve Cement Retainer
Ret. O.D. Model A Sleeve Valve Cement Retainer DIMENSIONAL DATA A B C D E F G H J K L M N P Q R 3.593 3.593 3.500 2.500 3.531 3.531 1.345 3.375.750.437 2.437 2.187 7.062 2.437 5.312 11.685 20.093 3.937
More informationFlow control valves Series RFU - RFO 2/
CATALOGUE > Release 8.5 > Valves Series RFU - RFO Flow control valves Series RFU - RFO Unidirectional and bidirectional flow control valves Ports: M5, G1/8, G1/4, G3/8 and G1/ Nominal diameter: M5 = 1,5
More informationInverse Proportional Pressure-Relief Cartridge, Size 10
Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size
More informationMODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL
MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL Index 1. List of components / General arrangement 2. Description 3. Handling 4. Installation 5. Actuators / Operation 6. Maintenance a. Changing
More informationVPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10
/ ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications
More information1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits
/-Way Angle-Seat Valve Type 000 to - NPT; 0 to 30 Advantages / Benefits Spring return closed or open, double-acting Materials: bronze, stainless steel High flow rate Self-adjusting packing glands with
More informationHYDAC BLADDER ACCUMULATORS INDEX Page: 1. DESCRIPTION FUNCTION CONSTRUCTION MOUNTING POSITION TYPE OF MOUNTING 3 2. APPLIC
Bladder Accumulators HYDAC BLADDER ACCUMULATORS INDEX Page: 1. DESCRIPTION 3 1.1. FUNCTION 3 1.2. CONSTRUCTION 3 1.3. MOUNTING POSITION 3 1.4. TYPE OF MOUNTING 3 2. APPLICATIONS 4 2.1. TYPICAL APPLICATIONS
More informationMounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity
Type 4708-45 Supply Pressure Regulator with increased air capacity Translation of original instructions Mounting and Operating Instructions EB 8546-1 EN Edition March 2016 Note on these mounting and operating
More informationDirect Operated Precision Regulator Modular Style. Standard Specifications
1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com
More informationSECTION 2 RING MOUNT
SECTION 2 RING MOUNT Rotax aircraft engines are manufactured and supported by Rotax GmbH of Austria. Read and understand the Rotax manuals completely before starting with the engine installation, as they
More informationType Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN
Type 4708-45 Pressure Regulator for increased air capacity Fig. 1: Type 4708-45 Pressure Regulator Mounting and Operating Instructions EB 8546-1 EN Edition March 2010 Definition of the signal words used
More informationOperating manual for the pressure transducer unit CCS 1000
Operating manual for the pressure transducer unit CCS 1000 Please read the operating manual before using the device. 1 Content: 1. General description 2. Technical data 3. Operation 4. Scope of supply
More informationSeries MX pressure regulators 3/
CATALOGUE > Release 8.8 > Series MX regulators Series MX pressure regulators MX2 ports: G/8, G1/2, G/4 - MX ports: G/4, G1 Manifold ports: G1/2 (MX2 only) Modular - Available with built-in pressure gauges
More informationBladder Accumulators Standard model
Bladder Accumulators Standard model 1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydraulic
More informationInstallation, operation & maintenance manual - original version
Installation, operation & maintenance manual - original version AVK gate valves for water and wastewater Series 01, 02, 06, 12, 15, 18, 20, 26, 32, 33, 36, 38, 50, 55 and 636 COPYRIGHT AVK GROUP A/S 2018
More informationPush-in fittings NPQH
Key features Application Effortless selection of the right fitting. Quick Star offers a secure solution for every connection. The convenient push-in fitting system includes well over 1000 types of standard
More informationE 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm
Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when
More informationTechnical Information TI-S10 Safety Locks. 2 Function. Contents
English translation of German original TI-S1 Safety Locks high holding force by self-reinforcing clamping hydraulic or pneumatic actuation for static loads For further information on technical data please
More informationSeries ZFC. Air Suction Filter In-line Type with One-touch Fittings
CAT.E832- A Air Suction Filter In-line Type with One-touch Fittings Series ZFC An in-line type air suction filter that prevents trouble in vacuum equipment due to contaminants in the air IN/OUT straight
More informationE 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min
Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow
More informationPoollift Delphin. Version: February, 2015 MANUAL AND OPERATING INSTRUCTIONS
Poollift Delphin Version: February, 2015 MANUAL AND OPERATING INSTRUCTIONS Content 1. Introduction... 3 2. Technical Specifications... 3 Used materials... 3 3. Installation Instructions... 4 Fastening
More informationDI-DRO ADVANCED FORMING SYSTEMS
DI-DRO ADVANCED FORMING SYSTEMS WE PARTNER WITH YOU We partner with you to provide force-generating products and solutions to lower your costs and increase your productivity in the forming of manufactured
More informationPressure relief valve, direct operated
Pressure relief valve, direct operated RE 570/0.05 Replaces: 06.03 /8 Type DBD..K Size Component series X Maximum operating pressure 500 bar Maximum flow 0 l/min K9- Table of contents Contents Page Features
More informationDouble Pilot Operated Cartridge Check Valve, Size 8
Double Pilot Operated Cartridge Check Valve, Size 8 Q max = 7 l/min (19 gpm), p max = 35 bar (5 psi) pilot operated, two-stage, spring-closed cartridge-type poppet valve Compact design for cavity type
More informationHEAVY DUTY PNEUMATIC
HEAVY DUTY PNEUMATIC Series A4 MEDIUM DUTY HYDRAULIC Series H4 PERMANENTLY LUBRICATED HEAVY DUTY PNEUMATIC Series L4 586.778.7680 SERIES A4/L4/H4 39 A4/L4/H4 FEATURES 1 1 9 9 12 8 7 5 12 3 13 4 10 2 11
More informationINSTALLATION GUIDE MODEL NUMBER X. UniMaxx-Plus-SC-500-AC-V3 UNIMAXX SOLAR PUMP STATION
INSTALLATION GUIDE UNIMAXX SOLAR PUMP STATION MODEL NUMBER X UniMaxx-Plus-SC-500-AC-V3 WWW.SUNMAXXSOLAR.COM Table of Contents 1 1.1 1.2 1.3 1.4 1.5 1.6 For Your Safety About This Manual Designated Use
More informationTHE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691
THE BP-690 SERIES Operating and Service Manual Series includes all variants of BP-LF/MF-690/691 Issue B April 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special
More informationFixed Displacement Motor A4FM
Industrial Hydraulics Electric Drives and Controls Linear Motion and ssembly echnologies Pneumatics Service utomation Mobile Hydraulics Fixed Displacement Motor 4FM RE 91 12/4. replaces: 3.95 and RE 91
More informationLeak-Free Load-Control Valve, Size 20
Leak-Free Load-Control Valve, Size 20 Qmax = 350 l/min [92 gpm], pmax = 420 bar [6000 psi] leak-proof, two-stage hydraulic, manifold mounting 20--P... 1 Description Whenever large loads are to be precisely
More informationSAFETY FIRST. Inspection Proper Set Up Proper Climbing & Use Proper Storage & Carrying Operating Instructions
SAFETY FIRST Inspection Proper Set Up Proper Climbing & Use Proper Storage & Carrying Operating Instructions Max weight on the 18 inch platforms 500 pounds SWL Certified at 2,000 pounds. Qualified under
More informationTA-COMPACT-P. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV)
Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV) IMI TA / Control valves / The pressure independent balancing and control valve ensures
More informationTANDEM plus BLUMOTION 563F installation instructions
56F installation instructions inside Full extension concealed runners Basic components ocking devices New side adjustment New rear side adjustment otate side adjustment left or right equally on both locking
More informationRelief Valves. Relief Valves. International, Inc. Company ACIRCOR. RS Differential NB 9.5mm. RVA In-line Differential NB 6 to 19mm
s s RS Differential NB 9.5mm RVA In-line Differential NB 6 to 19mm RV Direct Acting NB up to 9mm LPR Low Pressure Differential NB 8mm We design, machine, build and test all our products on one site in
More informationMaterials : Stainless steel ASTM A351 CF8M
Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 3/4" Male, hose coupling - 10 C + 150 C Max Pressure : 16 Bars Specifications : Anti blow-out stem Locking device With hose coupling Materials
More informationPressure Reducing Valve DMV 755
Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to
More informationSTIH) Technical Information Accessories for STIHL cut-off machines / drills. 1. New pressurized water tank
STIH) Technical Information 8.00 Accessories for STIHL cut-off machines / drills Contents. New pressurized water tank. Summary. New pressurized water tank The previous pressurized water tank 4 670 600
More informationWALLAS LEAD-THROUGHS 1066, 2460, 2466, 2467, 3467, 3468
Hull Picture Art.. (pipe) or combination Splash guard Stream resistance * Wind tolerance Temperature level of mounting surface Size and hight (mm) Sealable WALLAS LEAD-THROUGHS 1066, 2460, 2466, 2467,,
More informationTBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads
TBV-CM Combined control & balancing valves for small terminal units For modulating control NPT threads IMI TA / Control valves / TBV-CM TBV-CM Designed for use in terminal units in heating and cooling
More informationNerf N-Strike Elite Strongarm Spring Piston Chamber Replacement
Nerf N-Strike Elite Strongarm Spring Piston Chamber Replacement If your device isn t firing to its fullest capacity or even at all, there might be an issue with the spring piston chamber within your blaster.
More informationUnderwater Housing for Panasonic Lumix DMC-ZS60, DMC-TZ80
Underwater Housing for Panasonic Lumix DMC-ZS60, DMC-TZ80 Product Number 6170.60 Product Registration Please register your product at ikelite.com within 15 days of purchase. Our product registration database
More informationHeavy-duty three-point grippers HGDT
Key features At a glance The force generated by the linear motion is translated into the gripper jaw movement via a force-guided triple wedge mechanism. This also guarantees synchronous movement of the
More informationDiaphragm pressure switches, 42 V
0166 Diaphragm pressure switches, 42 V Zinc-plated steel body With push-on terminals Overpressure safe to 300 bar *) 0166 Diaphragm pressure switches Adjustment range Thread Normally open (no) : Normally
More informationPiloted Non-Return Valves
ed Non-Return Valves ed non-return valves are designed to protect installations: if the compressed air supply is removed, they lock the air supply to the cylinder, thus maintaining it in position. Product
More informationMin. Metered Flow Capacity L/min. Max. Oper. Pressure Kgf/cm (0.04)* F- FC G N -11 H01. Max. Metered Flow Capacity L/min.
Flow Control These are pressure and temperature compensating type valves and maintain a constant flow rate independent of change in system pressure (load) and temperature (Viscosity of the fluid). They
More informationSolid Roller stud mount
Solid Roller stud mount 60624 Material, urethane or neoprene bonded to a steel insert. Hardness from 20-80 durometer (Shore A). Technical Notes Bearings included (held in place with snap rings). For more
More information3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX
/-way valve, Series CD07 Version Spool valve, zero overlap Sealing principle soft sealing Working pressure min./max. -0.95 bar / 0 bar Ambient temperature min./max. -5 C / +80 C Medium temperature min./max.
More information- From 2005 year model, replacing with RM250 with 2-stroke engine, RM-Z450 with 4-stroke engine was introduced in the market. - From 2008 year model,
1 - From 2005 year model, replacing with RM250 with 2-stroke engine, RM-Z450 with 4-stroke engine was introduced in the market. - From 2008 year model, fuel injection system was introduced instead of carburetor
More information1000/13.02 KOBSERT. Thread inserts for metals
1000/13.02 KOBSERT Thread inserts for metals Contents KOBSERT Thread inserts for metals Page The principle 3 The benefits 3 Product types 3 Applications in the Automotive and General industry 4 Technical
More informationDWR6-205, DWR16-205, DWR6-206 Safety Pressure Limiters
Issue 2017-09-18 Datasheet 1.50-61.710-01-EN Safety Pressure Limiters pplication Safety pressure limiters with mechanical locking (switch lock) are used in steam and hot water plants in accordance with
More informationpipe connectors. General description of pipe connectors Development/Design Purpose Versions
Pipe connectors General description of pipe connectors 1 STFLEX pipe connectors, just like STFLEX rubber expansion joints, have been used for more than years as the preferred connection elements in appliance
More informationCompact pressure switches for gas and air
Compact pressure es for gas and air / 5.0 Printed in Germany Edition 0.8 Nr. 9 544 6 Technical description The pressure is an adjustable compact pressure according to EN 854 for combustion plants. The
More informationzkratka označení: PAL* technický list výrobku vytvořeno :13 1/6 pneumatický pohon série RE > tvrdý anodizovaný hliník NBR
pneumatický pohon série RE > tvrdý anodizovaný hliník zkratka označení: PAL* technický list výrobku Ausf Feder Modell Nm Port DW L B H kg RE161 RE1 RE043 RE6 RE161 RE1,1 bei 6 bar 35,5 bei 6 bar 70,6 bei
More informationoriginal operating manual Operating manual TankQuick 100 F2 Translation of the Item-No.:
Operating manual TankQuick 100 F2 Item-No.: 013895201 Translation of the original operating manual Important! Copyright The operating manual is always to be read before commissioning the equipment. No
More informationC 0G 00 N/US
G, GP, G, GP In-line flow regulators (block form) Uni-directional Ø /... / inch, Ø 4... mm High flow performance In-line or panel mounting Adjustment can be locked aptive regulator needle will not blow
More information