VRF. Technical Data Book. DVM S ECO for Europe (R410A, 50Hz, HP) Model : AM***KXMDGH/EU

Size: px
Start display at page:

Download "VRF. Technical Data Book. DVM S ECO for Europe (R410A, 50Hz, HP) Model : AM***KXMDGH/EU"

Transcription

1 VRF Technical Data Book DVM S ECO for Europe (R410A, Hz, HP) Model : AM***KXMDGH/EU

2 History Version Modification Date Remark 1 Newly Release the TDB

3 Nomenclature Outdoor Units Model Names AM 080 K X M D G H EU (1) (2) (3) (4) (5) (6) (7) (8) Buyer (1) Classification (5) Feature1 AM DVM V Inverter M DVM S Eco (2) Capacity x 1/10 HP (3 digits) (6) Feature2 A Standard + General Temp.+ MODULE (3) Version F 2013 H D High EER + Low Temp + Module STANDARD+GENERAL Temp.+NON MODULE H 2014 J 2015 K 2016 (7) Rating Voltage E 1Ø, 220~240V, Hz G 3Ø, 380~415V, Hz H 3Ø, 380V, 60Hz (4) Product Type X N Outdoor Unit Indoor Unit (8) Mode H Heat Pump R Heat Recovery

4 Outdoor 1 Specifications 2 Operation limit 3 Dimensional drawing 4 Electrical wiring diagram 5 Sound pressure level 6 Sound power level 7 Cycle diagram

5 1 Specifications Outdoor Type Model Name Power Supply Ø, #, V, Hz Mode - HP HP kw Cooling Performance Capacity Btu/h (Nominal) kw Heating Btu/h Power Input Cooling 1) kw (Nominal) Heating 2) kw Power Current Cooling 1) A Input (Nominal) Heating 2) A MCA A MFA A EER (Nominal Cooling) - COP COP (Nominal Heating) - Energy Grade - - Type - DVM S Eco(NEW) DVM S Eco(NEW) DVM S Eco(NEW) AM100KXMDGH/EU AM120KXMDGH/EU AM140KXMDGH/EU 3,4, , 3,4, , 3,4, , HP HP HP ,0 114, , ,0 128, , (MCA) 23. (MCA) (MCA) ESEER 7.09 ESEER 6.94 ESEER SSC Scroll x 1 SSC Scroll x 1 SSC Scroll x 1 Output kw x n (5.18) (6.39) (6.76) Compressor Model Name - Oil Type - Type - DS-GB052FAVB x 1 DS-GB066FAVB x 1 DS-GB070FAVA x Propeller Propeller Propeller Fan Piping Connections Output x n Air Flow Rate External Static Liquid Pipe Gas Pipe Max. Discharge Gas Pipe W CMM l/s mmaq Pa Ø, mm Ø, inch Ø, mm Ø, inch Ø, mm Ø, inch 244 x x x ,7.00 2, , /8" 1/2" 1/2" /8" 1 1/8" 1 1/8" Field Wiring Refrigerant Sound Installation Limitation Max. Length Max. Height Power Source Wire mm² Transmission Cable mm² Type - Factory Charging kg Pressure Power dba m m 160 (185) 160 (185) 160 (185) (40) (40) (40) ~ ~ ~ 1. R410A R410A R410A New Weight kg Shipping Weight kg External Dimension Net Dimensions (WxHxD) mm 940 x 1,630 x x 1,630 x x 1,630 x 460 Shipping Dimensions (WxHxD) mm 1,020 x 1,820 x 575 1,020 x 1,820 x 575 1,020 x 1,820 x 575 Operating Temp. Cooling ºC Heating ºC -5.0 ~ ~ ~ ~ ~ ~ 24.0 * Specifications may be subject to change without prior notice. 1) Nominal cooling capacities are based on; 2) Nominal heating capacities are based on; 3) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions. 4) These products contain R410A which is fluorinated greenhouse gas.

6 2 Operation limit Cooling Heating Outdoor temperature ( DB) Continuous Operation Range Outdoor temperature ( WB) Warming Up Operation Range Continuous Operation Range Indoor temperature( WB) Indoor temperature( DB) Defrosting correction factor On heating operation, frost can be formed on heat exchanger according to outdoor temperature. (Frost on heat exchanger results in decreasing the performance.) To remove frost on heat exchanger of outdoor unit, defrost operation is carried out periodically. During defrost operation, capacity of outdoor unit may decrease. The decrement is not considered to the individual capacity tables.

7 3 Dimensional drawing Outdoor AM100KXMDGH/EU, AM120KXMDGH/EU, AM140KXMDGH/EU

8 4 Electrical wiring diagram Outdoor AM100KXMDGH/EU, AM120KXMDGH/EU

9 4 Electrical wiring diagram Outdoor AM140KXMDGH/EU

10 5 Sound pressure level Outdoor Unit: db(a) Model Cooling AM100KXMDGH/EU 58 AM120KXMDGH/EU 59 AM140KXMDGH/EU 62 Note * Specifications may be subject to change without prior notice 1) These operation values were obtained in an anechoic room. 2) Sound pressure level will vary depending on a range of factors such as the construction of the particular room 3) Operation sound level may differ depending on operation and ambient conditions. NC curve 1) AM100KXMDGH/EU 80 2) AM120KXMDGH/EU Cooling NC 65 Cooling NC 65 Sound pressure level(db) NC 60 NC 55 NC NC 45 NC 40 Sound pressure level(db) NC 60 NC 55 NC NC 45 NC 40 NC 35 NC NC NC NC NC Octave band center frequency(hz) Octave band center frequency(hz) 3) AM140KXMDGH/EU Sound pressure level(db) Cooling NC 65 NC 60 NC 55 NC NC 45 NC 40 NC NC NC Octave band center frequency(hz)

11 6 Sound power level Outdoor Note * Specifications may be subject to change 1) dba = A-weighted sound power level. 2) Reference power : 1pW. 3) Measured according to ISO Unit: db(a) Model Power AM100KXMDGH/EU 74 AM120KXMDGH/EU 76 AM140KXMDGH/EU 79 1)AM100KXMDGH/EU 90 2)AM120KXMDGH/EU Sound power level(db) 60 Sound power level(db) Octave band center frequency(hz) Octave band center frequency(hz) 3)AM140KXMDGH/EU Sound power level(db) Octave band center frequency(hz)

12 7 Cycle diagram Outdoor AM100KXMDGH/EU, AM120KXMDGH/EU, AM140KXMDGH/EU E E v Service Valve (Gas) N Φ7.8 o M Φ6.8 j R E Q L K 5/8 1/4 O s 6A Φ7.8 u IPM F Φ6.8 H t Φ6.8 J g 7 mm e A Φ4.76x240mm 2A s X D Y Φ7.8 i ES P 6A Service Valve (Liquid) Name Name A INV comp R EEV bp check v/v B - S EVI EEV D L/P sensor X Hot gas bypass E,E OD Fan Motor Y Accum F Sub-cooler Z - H O/S E Disc. Sensor J H/P S/W G Comp Top sensor K Disc. check v/v I Liquid tube sensor L H/P Sensor J Suction sensor M 4Way V/V O Cond out sensor N OD HX t SC in sensor O EVI bypass V/V u SC out sensor P EVI V/V v Ambient air sensor Q Main EEV

13 DVM Capacity 1 Capacity table 2 Capacity correction

14 1 Capacity table AM100KXMDGH/EU Cooling Combination, % (Capacity index) Outdoor Air Temp. TC : Total Capacity, PI : Power Input Indoor temperature 20 (ºC, DB) 23 (ºC, DB) 26 (ºC, DB) 27 (ºC, DB) 28 (ºC, DB) 30 (ºC, DB) 32 (ºC, DB) 14 (ºC, WB) 16 (ºC, WB) 18 (ºC, WB) 19 (ºC, WB) 20 (ºC, WB) 22 (ºC, WB) 24 (ºC, WB) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) * Capacity table may be subject to change without prior notice. 1) Capacity table comply with EN ) Nominal cooling capacities are based on; 3) Nominal heating capacities are based on;

15 1 Capacity table AM100KXMDGH/EU Cooling Combination, % (Capacity index) Outdoor Air Temp. TC : Total Capacity, PI : Power Input Indoor temperature 20 (ºC, DB) 23 (ºC, DB) 26 (ºC, DB) 27 (ºC, DB) 28 (ºC, DB) 30 (ºC, DB) 32 (ºC, DB) 14 (ºC, WB) 16 (ºC, WB) 18 (ºC, WB) 19 (ºC, WB) 20 (ºC, WB) 22 (ºC, WB) 24 (ºC, WB) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) * Capacity table may be subject to change without prior notice. 1) Capacity table comply with EN ) Nominal cooling capacities are based on; 3) Nominal heating capacities are based on;

16 1 Capacity table AM100KXMDGH/EU Heating Combination, % (Capacity index) Outdoor Air Temp. DB WB TC : Total Capacity, PI : Power Input Indoor temperature 16 (ºC, DB) 18 (ºC, DB) 20 (ºC, DB) 22 (ºC, DB) 24 (ºC, DB) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) * Capacity table may be subject to change without prior notice. 1) Capacity table comply with EN ) Nominal cooling capacities are based on; 3) Nominal heating capacities are based on;

17 1 Capacity table AM100KXMDGH/EU Heating Combination, % (Capacity index) Outdoor Air Temp. DB WB TC : Total Capacity, PI : Power Input Indoor temperature 16 (ºC, DB) 18 (ºC, DB) 20 (ºC, DB) 22 (ºC, DB) 24 (ºC, DB) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) * Capacity table may be subject to change without prior notice. 1) Capacity table comply with EN ) Nominal cooling capacities are based on; 3) Nominal heating capacities are based on;

18 1 Capacity table AM100KXMDGH/EU Heating Combination, % (Capacity index) Outdoor Air Temp. DB WB TC : Total Capacity, PI : Power Input Indoor temperature 16 (ºC, DB) 18 (ºC, DB) 20 (ºC, DB) 22 (ºC, DB) 24 (ºC, DB) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) * Capacity table may be subject to change without prior notice. 1) Capacity table comply with EN ) Nominal cooling capacities are based on; 3) Nominal heating capacities are based on;

19 1 Capacity table AM120KXMDGH/EU Cooling Combination, % (Capacity index) Outdoor Air Temp. TC : Total Capacity, PI : Power Input Indoor temperature 20 (ºC, DB) 23 (ºC, DB) 26 (ºC, DB) 27 (ºC, DB) 28 (ºC, DB) 30 (ºC, DB) 32 (ºC, DB) 14 (ºC, WB) 16 (ºC, WB) 18 (ºC, WB) 19 (ºC, WB) 20 (ºC, WB) 22 (ºC, WB) 24 (ºC, WB) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) * Capacity table may be subject to change without prior notice. 1) Capacity table comply with EN ) Nominal cooling capacities are based on; 3) Nominal heating capacities are based on;

20 1 Capacity table AM120KXMDGH/EU Cooling Combination, % (Capacity index) Outdoor Air Temp. TC : Total Capacity, PI : Power Input Indoor temperature 20 (ºC, DB) 23 (ºC, DB) 26 (ºC, DB) 27 (ºC, DB) 28 (ºC, DB) 30 (ºC, DB) 32 (ºC, DB) 14 (ºC, WB) 16 (ºC, WB) 18 (ºC, WB) 19 (ºC, WB) 20 (ºC, WB) 22 (ºC, WB) 24 (ºC, WB) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) * Capacity table may be subject to change without prior notice. 1) Capacity table comply with EN ) Nominal cooling capacities are based on; 3) Nominal heating capacities are based on;

21 1 Capacity table AM120KXMDGH/EU Heating Combination, % (Capacity index) Outdoor Air Temp. DB WB TC : Total Capacity, PI : Power Input Indoor temperature 16 (ºC, DB) 18 (ºC, DB) 20 (ºC, DB) 22 (ºC, DB) 24 (ºC, DB) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) * Capacity table may be subject to change without prior notice. 1) Capacity table comply with EN ) Nominal cooling capacities are based on; 3) Nominal heating capacities are based on;

22 1 Capacity table AM120KXMDGH/EU Heating Combination, % (Capacity index) Outdoor Air Temp. DB WB TC : Total Capacity, PI : Power Input Indoor temperature 16 (ºC, DB) 18 (ºC, DB) 20 (ºC, DB) 22 (ºC, DB) 24 (ºC, DB) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) * Capacity table may be subject to change without prior notice. 1) Capacity table comply with EN ) Nominal cooling capacities are based on; 3) Nominal heating capacities are based on;

23 1 Capacity table AM120KXMDGH/EU Heating Combination, % (Capacity index) Outdoor Air Temp. DB WB TC : Total Capacity, PI : Power Input Indoor temperature 16 (ºC, DB) 18 (ºC, DB) 20 (ºC, DB) 22 (ºC, DB) 24 (ºC, DB) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) * Capacity table may be subject to change without prior notice. 1) Capacity table comply with EN ) Nominal cooling capacities are based on; 3) Nominal heating capacities are based on;

Contents. Introduction Part 1 General Information Part 2 General Instruction Part 3 Outdoor Units Part 4 Installation...

Contents. Introduction Part 1 General Information Part 2 General Instruction Part 3 Outdoor Units Part 4 Installation... MHVAC-DTSM-2012-07 Contents Contents Introduction... 1 Part 1 General Information... 2 Part 2 General Instruction... 13 Part 3 Outdoor Units... 17 Part 4 Installation... 316 Part 5 Control System... 356

More information

Part 1 General Information Part 2 Outdoor Units... 8

Part 1 General Information Part 2 Outdoor Units... 8 Contents Part 1 General Information... 1 Part 2 Outdoor Units... 8 Part 3 Installation... 71 Part 4 Part 5 Trouble shooting 99 Control system. 126 Manufacture reserves the right to discontinue, or change

More information

FMU4X, FMC4X FMU4P, FMC4P

FMU4X, FMC4X FMU4P, FMC4P ENVIRONMENTALLY SOUND REFRIGERANT FMU4X, FMC4X FMU4P, FMC4P Product Specifications HORIZONTAL FAN COILS FMU4P and FMC4P 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2 and 2 1/2 Tons ALL MODELS Horizontal

More information

Compresor lg de BTU modelo QP325KCB

Compresor lg de BTU modelo QP325KCB Compresor lg de 24000 BTU modelo QP325KCB Compresor lg de 24000 BTU modelo QP325KCB Ref. No. LGETA-140115-1576 Issued Date 2014.01.15 0.Revision History Rev. No. Rev. 0 Rev. Date - Data Rev. No Rev. description

More information

market leading commercial and domestic ventilation with heat recovery Nilan VPM Active heat recovery and cooling (air/air)

market leading commercial and domestic ventilation with heat recovery Nilan VPM Active heat recovery and cooling (air/air) market leading commercial and domestic ventilation with heat recovery Nilan VPM 120-560 Active heat recovery and cooling (air/air) Nilan VPM 120-560 Industrial ventilation with heat recovery and cooling

More information

AIR CONDITIONERS WA14 SERIES

AIR CONDITIONERS WA14 SERIES FORM NO. A66-220 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light

More information

AIR CONDITIONERS WA14**W SERIES

AIR CONDITIONERS WA14**W SERIES FORM NO. A66-225 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light

More information

Heat pumps for swimming pools

Heat pumps for swimming pools Heat pumps for swimming pools Full range of heat pumps for indoor and outdoor swimming i pools The best heating for your pool Reliable and effective Made in Europe www.calorex.com THE CHALLENGE: To provide

More information

4HP15 PRODUCT SPECIFICATIONS 15 SEER SPLIT SYSTEM HEAT PUMP

4HP15 PRODUCT SPECIFICATIONS 15 SEER SPLIT SYSTEM HEAT PUMP 4HP15 PRODUCT SPECIFICATIONS 15 SPLIT SYSTEM HEAT PUMP FORM NO. 4HP15-100 (12/2017) FEATURES AND BENEFITS R410A Refrigerant High-quality condenser coil with copper tubing and enhanced louvered fin for

More information

LIEBERT DS TOP VIEW FRONT VIEW. This document has been generated on 22 September :18 PM (EST). Dry Weight (approximate) lb.

LIEBERT DS TOP VIEW FRONT VIEW. This document has been generated on 22 September :18 PM (EST). Dry Weight (approximate) lb. " 88mm 5" 889mm CBINET DIMENSIONL DT DS DOWNFLOW IR COOLED 5-77kW (15-22 TONS) W/ SCROLL OR DIGITL SCROLL COMPRESSOR MODELS Secondary Refrigerant Piping Entrance 80" 202mm Opening IR INLET OPENING 2 /8"

More information

How to Select High Pressure and Gas Bypass

How to Select High Pressure and Gas Bypass Application Guide How to Select High Pressure and Gas Bypass Valves This Application Guide provides a theoretical explanation of how to select the optimum high pressure valves and gas bypass valves for

More information

DLE7.5CN V/50Hz 1~

DLE7.5CN V/50Hz 1~ dle75cn_102h4856_r290_2v_50hz_06-18_ds.xlsx Sales code: 102H4856 DLE7.5CN 2-240V/50Hz 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 7,48cm³ / 0,46cu.in Oil quantity

More information

NLE10CN V/50Hz 1~

NLE10CN V/50Hz 1~ nle10cn_105h6175_r290_2v_50hz_06-18_ds.xlsx Sales code: 105H6175 NLE10CN 2-240V/50Hz 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 10,09cm³ / 0,62cu.in Oil quantity

More information

DLE5.7CN V/60Hz 1~

DLE5.7CN V/60Hz 1~ dle57cn_102h3682_r290_115v_60hz_06-18_ds.xlsx Sales code: 102H3682 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 5,7cm³ / 0,35cu.in Oil quantity 221cm³ / 7,5fl.oz

More information

Ducted Reverse Cycle Air Conditioning of Distinction

Ducted Reverse Cycle Air Conditioning of Distinction Ducted Reverse Cycle Air Conditioning of Distinction Transforming global energy-efficiency into an art form! The Braemar advantage Braemar ducted reverse cycle air conditioners are brought to you by Seeley

More information

DLE6.5CN V/60Hz 1~

DLE6.5CN V/60Hz 1~ dle65cn_102h3792_r290_115v_60hz_06-18_ds.xlsx Sales code: 102H3792 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 6,5cm³ / 0,4cu.in Oil quantity 221cm³ / 7,5fl.oz s

More information

RP series Rotor Pumps

RP series Rotor Pumps ontact etails RP series Rotor Pumps Nomenclature Features Low noise Substantial reduction of the operation noise, by to db (comparison with aikin products), and improved sound quality are achieved by adopting

More information

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype (R744) Service Station Presentation Contents Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype Page 1 (R744) Service Station Goals Usability Full automatic

More information

NLE11CNL V/60Hz 1~

NLE11CNL V/60Hz 1~ nle11cnl_105h5981_r290_115v_60hz_11-18_ds.xlsx Sales code: 105H5981 NLE11CNL 115-7V/60Hz 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 11,15cm³ / 0,68cu.in Oil quantity

More information

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

VARIABLE SPEED AIR CONDITIONERS

VARIABLE SPEED AIR CONDITIONERS FORM NO. AFJ-224 Supersedes Form No. AFJ-222 VARIABLE SPEED AIR CONDITIONERS FO*20C SERIES Efficiencies up to 20 SEER/13 EER Nominal Sizes 2, 3, 4 & 5 Ton [7.03, 10.6, 14.06 & 17.6 kw] Cooling Capacities

More information

Page - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302

Page - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302 CONTENTS. Page - SPECIFICATIONS 200 SPECIFICATION 200 SELECTION CHART PFC 201 SELECTION CHART 202 TYPE KEY AND CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 2 204 PERFORMANCE CURVE 3 205 PERFORMANCE CURVE

More information

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42 Data sheet Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42 The CCMT is an electrically operated valve designed specifically for operation in CO 2 systems. The CCMT valve concept is

More information

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No.

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No. FORM NO. AFJ-222 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*16C SERIES Efficiencies up to 16 SEER/13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to

More information

RS 2-75 D 109 D RSF 87 D 127 D with direct drive

RS 2-75 D 109 D RSF 87 D 127 D with direct drive Screw compressors RS 2-75 D 109 D RSF 87 D 127 D with direct drive Made in Germany Motor size: 75 127 kw RENNER GmbH Kompressoren Success Rooted in Tradition. RENNER GmbH Kompressoren have been known for

More information

System Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner

System Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner System Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner Mohammad Khawaldeh Director, Unitary & Applied Product Units Presentation Outline Objectives Challenges Base

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

Automatic Control Unit. Controlmatic E. Type Series Booklet

Automatic Control Unit. Controlmatic E. Type Series Booklet Automatic Control Unit Controlmatic E Type Series Booklet Legal information/copyright Type Series Booklet Controlmatic E All rights reserved. The contents provided herein must neither be distributed, copied,

More information

Accessories. Valves. Adjustable Pressure Relief Valves

Accessories. Valves. Adjustable Pressure Relief Valves Valves djustable Pressure Relief Valves djustable pressure relief valves allow for variable operating pressures anywhere between PSI ( bar). In order to prevent overloading of the motor, however, the maximum

More information

RS D RSF D with direct drive

RS D RSF D with direct drive Screw compressors RS 2-75 109 D RSF 87 127 D with direct drive Made in Germany Motor power: 75 127 kw RENNER GmbH Kompressoren success rooted in tradition. RENNER GmbH Kompressoren have been known for

More information

Differential pressure switch MP 54, MP 55 and MP 55A

Differential pressure switch MP 54, MP 55 and MP 55A Data sheet Differential pressure switch MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors against low lubricating

More information

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No.

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No. FORM NO. AFJ-221 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*13C SERIES Efficiencies 13-15.5 SEER/11.5-13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7

More information

Automatic Control Unit. Controlmatic E.2. Type Series Booklet

Automatic Control Unit. Controlmatic E.2. Type Series Booklet Automatic Control Unit Controlmatic E.2 Type Series Booklet Legal information/copyright Type Series Booklet Controlmatic E.2 All rights reserved. The contents provided herein must neither be distributed,

More information

MAINLINE MLA14 AIR CONDITIONERS

MAINLINE MLA14 AIR CONDITIONERS FORM NO. AML-220 Supersedes Form No. PTZ-789 MAINLINE AIR CONDITIONERS Efficiencies up to 16 /13 Nominal Sizes 1.5-5 Ton [5.28 TO 17.6 KW] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured

More information

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No.

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No. FORM NO. AFJ-220 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*14C SERIES Efficiencies up to 16 S/13 Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7

More information

erc-o 2 -tech Ò innovative gas systems Markwerbener Str Weißenfels Germany

erc-o 2 -tech Ò innovative gas systems Markwerbener Str Weißenfels Germany Compart Umwelttechnik GmbH erc-o 2 -tech Ò innovative gas systems Markwerbener Str. 24 06667 Weißenfels Germany Phone: 0049 (0) 3443/2901-0 Fax: 0049 (0) 3443/2901-12 Mail: compart-weissenfels@t-online.de

More information

Pressure switch KP-E. Data sheet

Pressure switch KP-E. Data sheet Data sheet Pressure switch KP-E KP-E pressure switches for use in refrigeration and air conditioning systems are equipped with SPDT gold plated contacts and stainless steel bellows. The high pressure switches

More information

Soft-optimization test of R-410A alternative refrigerant R-32 in a split condensing unit - Phase II

Soft-optimization test of R-410A alternative refrigerant R-32 in a split condensing unit - Phase II Soft-optimization test of R-410A alternative refrigerant R-32 in a split condensing unit - Phase II Stephen Li Daikin / Goodman Manufacturing Jan. 2016 1 2 Test objectives See the impact of R-32 on air

More information

Oil-injected rotary screw compressors GA (VSD + )

Oil-injected rotary screw compressors GA (VSD + ) Oil-injected rotary screw compressors GA 90 + 160 (VSD + ) Highest reliability, lowest operating costs The shortest route to maximize your profitability is to minimize your operational costs. With up to

More information

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners M/MR Modulating Valves design certified For Atmospheric, Infrared, and Direct Fired urners TALE OF CONTENTS Description/Specifications... 1 Introduction... 2 Direct Fired Applications (Negative Pressure)...

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

Danfoss scroll compressors DSH

Danfoss scroll compressors DSH Application guidelines Danfoss scroll compressors DSH 090-184 50 Hz - 60 Hz - R410A http://cc.danfoss.com Content... 4... 5 Features... 5 Overview...5 How do IDVs work?...5 Compressor model designation...

More information

Standard 1/4 compressor chiller/heat pump with heating recovery Manual version: /02/97

Standard 1/4 compressor chiller/heat pump with heating recovery Manual version: /02/97 Application program for Macroplus II Standard 1/4 compressor chiller/heat pump with heating recovery Manual version: 2.2-06/02/97 Program code: EP000EPDC0 Rif.: 17EM INDEX MAIN FEATURES...2 Hardware Description...2

More information

STAINLESS STEEL GRAND SERIES

STAINLESS STEEL GRAND SERIES STAINLE STEEL GRAND SERIES STAINLE STEEL GRAND SERIES DEEPWELL SUBMERSIBLE PUMPS STAINLE STEEL - GRAND SERIES C.R.I. Always equips itself in advance to face the exponentially growing technological challenges

More information

Accessories. Valves. Adjustable Pressure Relief Valves

Accessories. Valves. Adjustable Pressure Relief Valves Valves Adjustable Pressure Relief Valves Adjustable pressure relief valves allow for variable operating pressures anywhere between PSI ( bar). In order to prevent overloading of the motor, however, the

More information

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2 The Bray Simple Set is a threaded pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SS Series combines high rangeability control

More information

Automatic Control Unit. Cervomatic EDP.2. Type Series Booklet

Automatic Control Unit. Cervomatic EDP.2. Type Series Booklet Automatic Control Unit Cervomatic EDP.2 Type Series Booklet Legal information/copyright Type Series Booklet Cervomatic EDP.2 All rights reserved. The contents provided herein must neither be distributed,

More information

Earlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System.

Earlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System. 17 1 Earlier Lecture In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System. Collins system is an extension of the Claude system to reach lower

More information

Technical Instructions Document No. CA2N4721E-P25 Rev. 1, February, Modulating Control Valve for Hot Gas Control.

Technical Instructions Document No. CA2N4721E-P25 Rev. 1, February, Modulating Control Valve for Hot Gas Control. Document No. CAN7E-P MFB LX Series Modulating Control Valve Description Valves with magnetic actuator for modulating capacity control of refrigeration units and for heat recovery. Features Quick positioning

More information

Differential pressure switch / Lube oil protection control MP 54 and MP 55

Differential pressure switch / Lube oil protection control MP 54 and MP 55 Data sheet Differential pressure switch / Lube oil protection control MP 54 and MP 55 MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors

More information

Differential Pressure Control Types MP 54, MP 55 and MP 55A

Differential Pressure Control Types MP 54, MP 55 and MP 55A MAKING MODERN LIVING POSSIBLE Data sheet Differential Pressure Control Types MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure controls are used as safety switches to protect refrigeration

More information

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic Pharmaceutical SRL Series Oil-less Scroll Air Compressors Research & Development Food & Beverage Chemical Electronic Hitachi Industrial Equipment Product Brochure Hitachi SRL Series scroll compressors

More information

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT CAUTION!

More information

Solenoid valve type EVR for Hydrocarbons

Solenoid valve type EVR for Hydrocarbons MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid valve type EVR for Hydrocarbons EVR for Hydrocarbons is a direct or servo operated solenoid valve especially designed for liquid, suction, and

More information

Refrigeration and Air Conditioning Technical leaflet

Refrigeration and Air Conditioning Technical leaflet Refrigeration and Air Conditioning Technical leaflet Technical leaflet Injection valve type 2 Introduction Danfoss has developed a injection valve type 2 for desuperheating in 2-stage refrigeration systems

More information

Model 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33.

Model 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33. EVAPORATOR COILS A COIL UNCASED R 22 or R 410A SYSTEMS 1 5 Tons WEAU Certification applies only when the complete system is listed with ARI ISO 9001:2000 REGISTERED R 410A R 22 Size Shipping Weight Size

More information

Ruud Achiever Series Heat Pump

Ruud Achiever Series Heat Pump Heat Pumps Ruud Achiever Series Heat Pump RP14**F Series Efficiencies: 14-15 SEER/11.5-12.5 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper

More information

GasSense NDIR User Manual

GasSense NDIR User Manual INDEX INDEX... 1 1. OVERVIEW... 2 2. TECHNICAL DATA... 3 3. SPECIFICATIONS... 4 4. PRODUCT DESCRIPTION... 5 4.1 Mechanical details... 5 4.2 Piping... 7 4.3 Connections... 7 5. INSTALLATION... 10 6. CALIBRATION

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure

More information

Monitoring device NTS 30

Monitoring device NTS 30 P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit

More information

DATA & FACTS Compressor-Condensing Unit GLCU BC1/2(.SL) Air-Cooled Compressor Condensing Unit for Outdoor Installation

DATA & FACTS Compressor-Condensing Unit GLCU BC1/2(.SL) Air-Cooled Compressor Condensing Unit for Outdoor Installation DATA & FACTS Compressor-Condensing Unit GLCU 2015-4060 BC1/2(.SL) Air-Cooled Compressor Condensing Unit for Outdoor Installation Table of contents GLCU 2015-4051 BC1 Table of Contents... 2 Unit type code...

More information

Sequence of Operations

Sequence of Operations MAGNUM Condensing Unit Software 5580 Enterprise Pkwy. Fort Myers, FL 33905 Office: 239-694-0089 Fax: 239-694-0031 Sequence of Operations MAGNUM Chiller V8 software www.mcscontrols.com MCS Total Solution

More information

Advance Service & Troubleshooting

Advance Service & Troubleshooting Rev 2.1 Advance Service & Troubleshooting TOPICS Reference & General Information Troubleshooting & Service Modes Communication Errors Compressor Errors EEV Errors IPM/Inverter Errors Temperature Sensor

More information

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type. Process Pump Series 3/5 Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted

More information

Differential pressure controls, Type MP 54, 55 and 55A

Differential pressure controls, Type MP 54, 55 and 55A MAKING MODERN LIVING POSSIBLE Technical brochure Differential pressure controls, Type MP 54, 55 and 55A MP 54 and oil pressure controls are used as safety switches to protect refrigeration compressors

More information

MAINLINE MLP14**A HEAT PUMPS

MAINLINE MLP14**A HEAT PUMPS FORM NO. PML-806 REV. 2 Supersedes Form No. PTZ-789 MAINLINE HEAT PUMPS Efficiencies: 15 SEER/12.5 EER 9 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to

More information

ASERCOM guidelines for the design of multiple compressor racks using frequency inverters

ASERCOM guidelines for the design of multiple compressor racks using frequency inverters ASERCOM guidelines for the design of multiple compressor racks using frequency inverters Contents 1 SCOPE AND PURPOSE 2 SELECTION OF COMPRESSORS 3 DESIGN FEATURES 4 CONTROL FEATURES 5 STABILITY OF WORKING

More information

Semi-Hermetic compact screw compressors

Semi-Hermetic compact screw compressors CX Series Frascold CX compact screw compressors range has been designed to grant the maximum efficiency, reliability and flexibility. Currently the range consists of 566 models, which cover not only a

More information

Pilot valves for pilot operated servo valves

Pilot valves for pilot operated servo valves Data sheet Pilot valves for pilot operated servo valves The range of pilot valves consists of: Constant-pressure pilot valve, type CVP (LP) and CVP (HP) Differential-pressure pilot valve, type CVPP (LP)

More information

TRANSCRITICAL CO 2 IN AUSTRALIAN SUPERMARKETS. Mike Baker Baker Refrigeration M. IE Aust, C P ENG, M. AIRAH

TRANSCRITICAL CO 2 IN AUSTRALIAN SUPERMARKETS. Mike Baker Baker Refrigeration M. IE Aust, C P ENG, M. AIRAH TRANSCRITICAL CO 2 IN AUSTRALIAN SUPERMARKETS Mike Baker Baker Refrigeration M. IE Aust, C P ENG, M. AIRAH TRANSITION TO TRANSCRITICAL Drakes Angle Vale, SA First Generation Coles Coburg North, Vic Second

More information

Development of Large Capacity CO2 Scroll Compressor

Development of Large Capacity CO2 Scroll Compressor Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2008 Development of Large Capacity CO2 Scroll Compressor Kenji Yano Mitsubishi Electric

More information

Pressure transmitters EMP 2

Pressure transmitters EMP 2 Data sheet Pressure transmitters EMP 2 The high accuracy pressure transmitter EMP 2 is designed for monitoring and control in marine and industial applications and offers a reliable pressure measurement,

More information

Standard Chiller 1/4 compressors Manual version: /10/96

Standard Chiller 1/4 compressors Manual version: /10/96 Application program for Macroplus II Standard Chiller 1/4 compressors Manual version: 1.4-18/10/96 Program code: EP000ECH02 Rif.: 68EM Contents 0$,1)($785(6 HARDWARE...2 FUNCTIONS OF THE SYSTEM...3 PROTECTIONS...3

More information

Rheem Classic Series Heat Pump

Rheem Classic Series Heat Pump Heat Pumps Rheem Classic Series Heat Pump Efficiencies: up to 14 SEER/11.5 EER/8.2 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing

More information

Centriflow Plus High-pressure plug fan - Technical Data

Centriflow Plus High-pressure plug fan - Technical Data Centriflow Plus 3 High-pressure plug fan - Technical Data Contents General description...3 General survey chart...4 Design description Fan Impeller...5 Fan Inlet...5 base with base frame...5 Hub...5 Air

More information

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz GRUNDFOS DATA BOOKLET Complete pressure boosting systems 5/6 z Contents Product data Performance range 3 Operating conditions Inlet pressure Type key Product range 5 Construction 5 Installation 5 Mechanical

More information

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2012 Gas Vapor Injection on Refrigerant Cycle Using Piston Technology Sophie

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

Model PDT Dewpoint Transmitter

Model PDT Dewpoint Transmitter Model PDT Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk

More information

LindabSolus. Supply air beam. lindab we simplify construction

LindabSolus. Supply air beam. lindab we simplify construction lindab we simplify construction Lindab 03.2016 Lindab Ventilation. All forms of reproduction without written permission are forbidden. is the registered trademark of Lindab AB. Lindab's products, systems,

More information

Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING. Technical leaflet Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction...3 Features...3 Technical data...4 Ordering...4 Sizing...5 Valve selection...5

More information

SP/ST/SA Models Pulse-input and Analog-input Control

SP/ST/SA Models Pulse-input and Analog-input Control SP/ST/SA Pulse-input and -input Control Smart and Intuitive Operation Simple key functions and user interface for ease of operation. Range can be set between 1 and 3 strokes per minute in 1-stroke units.

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication

More information

Crankcase pressure regulator, type KVL REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Crankcase pressure regulator, type KVL REFRIGERATION AND AIR CONDITIONING. Technical leaflet Crankcase pressure regulator, type KVL REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction.......................................................................................

More information

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners BULLETIN MT2035-07/05 Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners M/MR Series M411, M511, M611 M420, M520, M620, MR410, MR510, MR610 MR212D, MR212E, MR212G and MR212J (Flanged),

More information

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions. Oxford Instruments Plasma Technology www.oxford-instruments.com About this data sheet This data sheet provides basic information about the installation of a tool. Floor and wall loadings Table 1 lists

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MODEL GS2000 / GS2001 OIL-LESS REFRIGERANT RECOVERY UNIT NATIONAL REFRIGERATION PRODUCTS 985 WHEELER WAY LANGHORNE, PA 19047 (215) 638-8909 FAX (215) 638-9270 R01099 GS2000.DOC NRP-OM-GS2000

More information

2-step solenoid valve Type ICLX

2-step solenoid valve Type ICLX Data sheet 2-step solenoid valve ICLX 32-150 ICLX 2-step solenoid valves belong to the ICV family. ICLX are used in suction lines for the opening against high differential pressure, e.g. after hot gas

More information

Rheem Classic Series Heat Pump

Rheem Classic Series Heat Pump Heat Pumps Rheem Classic Series Heat Pump Efficiencies: 14 SEER/11.5 EER 8.2 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and

More information

Electric expansion valves Types AKV 10, AKV 15 and AKV 20

Electric expansion valves Types AKV 10, AKV 15 and AKV 20 Data sheet Electric expansion valves Types AKV 10, AKV 15 and AKV 20 AKV are electrically operated expansion valves designed for refrigerating plants. The AKV valves are normally controlled by a controller

More information

Electro Controls. Pressure WattsIndustries.co.uk

Electro Controls. Pressure WattsIndustries.co.uk Electro Controls Pressure - 07 WattsIndustries.co.uk PRESSURE AIR DIFFERENTIAL PRESSURE SWITCHES EDA.. EFS.. To monitor air flow, dirty filters, flue draught, frost on coils & level. For positive, negative,

More information

2-step solenoid valve Type ICLX

2-step solenoid valve Type ICLX Data sheet 2-step solenoid valve ICLX 32-150 ICLX 2-step solenoid valves belong to the ICV family. ICLX are used in suction lines to open against high differential pressure, e.g. after a hot gas defrost

More information

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Glycol Systems Engineering Manual 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Stulz Air Technology Systems, Inc. Table of Contents Section - 1 Table

More information

Tightness controls TC 1 3 and TC 4

Tightness controls TC 1 3 and TC 4 Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems

More information

RA-N radiator valves with integrated presetting and self-sealing tailpiece

RA-N radiator valves with integrated presetting and self-sealing tailpiece Data sheet RA-N radiator valves with integrated presetting and self-sealing tailpiece EN 215 Application Straight version Angle version Horizontal angle version All RA-N valve bodies can be used together

More information

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according

More information

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x Electrical Installation Requirements Care should be taken to separate the power and signal cables to prevent electrical interference and possible damage due to inadvertent connection. SUPPLY E L N LN2

More information

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide Pilot HON 62 Entwurf Product information serving the gas industry worldwide Pilot HON 62 Application, characteristics Application Pilot for the gas pressure regulator HON 02 Pilot for outlet pressure control

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability

More information

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet Gas powered stop valves, type GPLX 80-150 REFRIGERATION AND AIR CONDITIONING Technical leaflet Technical leaflet Gas powered stop valves, type GPLX 80-150 Contents Page Introduction........................................................................................3

More information