1 BREATHING CIRCUIT 019

2 Table of contents Breathing Circuit 01 Neonatal Care 1 Anesthesia Circuit 9 Accessories 7

3 Breathing Circuit Device - Heated Respiratory Humidifier - Humidification Chamber - Expiratory Filter Heater Reusable Breathing Circuit Disposable Breathing Circuit - Heated Wire - Ventilator Circuit - IPPB Breathing System - Breathing System with Water Trap - Flow Sensor - Accessories

4 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES Auto Respiratory Humidifier Feature a. A friendly turn-on button to choose NIV or IV. b. Press down the panel to slide in the chamber on the heat-plate. c. Prevention for mis-connection. d. Alarm indicators. e. Multi-functional LED display. f. Compatible with all device. Specification Supply Voltage Heater Plate Temperature Range Heater Plate Temperature Weight Dimension Standards Compliance HC-700 HC-700 Specification Supply Voltage Heater Plate Heat Control Heater Plate Temperature Weight Dimension Standards Compliance 110VAC/60 Hz; 0VAC/50 Hz 150W Invasive Mode 5 O C - O C Non-Invasive Mode 8 O C - 6 O C 10 O C - 70 O C Approx..Kg 10 (L) x 170 (W) x 18 (H) mm IEC , IEC , ISO 8185 AC 100V-10V, 50/60Hz AC 0V-0V, 50/60Hz Manual Respiratory Humidifier 110VAC/60 Hz; 0VAC/50 Hz 85W Level O C ~ 7 O C Approx. 1.Kg 10 (L) x 170 (W) x 18 (H) mm IEC , IEC Temperature Probe HC-70 HC-7017 HC-7018 d b e a For Use with Circuits 1.1m (") in Length For Use with Circuits 1.m (5") in Length For Use with Circuits 1.5m (60") in Length c Device HC-7100 HC-700 AC 100V-10V, 50/60Hz AC 0V-0V, 50/60Hz Besmed Best Choice for Care.

5 Device Humidification Chamber Feature of HC-7600 a. -in-1 solution, eliminate tissue for moisture absorption. b. Retain Humidity is above level. c. Additional connector is provided for different application. Specification Type Inlet/Outlet (mm) Compressible Volume (ml) Maximum Water Capacity (ml) Maximum Peak Flow (L/min) Resistance (cmh O/L/S) Compliance (ml/cmh O) Chassis Diameter (mm) Material IV line (cm) Autoclavable Weight (g) Heater Wire Adaptor For use with the MR850 & MR70, HC-700 & HC-700 Humidifier Single Dual F&P Connector Molex Connector LEMO Connector HC-701 For RT,CT Series disposable heated breathing circuits. HC-701 For RT,CT Series disposable dual heated breathing circuits. HC-7600 Reusable Manual Feeding / PSF - 1 C 08 HC-7010 For CT Series disposable heated breathing circuits with Molex connector. HC-701 For CT Series disposable dual heated breathing circuits with Molex connector. HC-7 Disposable Manual Feeding / PS HC-710 Disposable Manual Feeding / PS HC-7011 For HC Series reusable heated breathing circuits with LEMO connector. HC-7015 For HC Series reusable dual heated breathing circuits with LEMO connector. HC-7600 Reusable HC-718 Disposable Auto-Feeding / PS BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES info@besmed.com

6 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES Expiratory Filter Heater and Accessories Expiratory Filter Heater FL FL-7000 WT WT NA AC 100V-10V, 50/60HZ AC 0V-0V, 50/60HZ Durable Water Trap Kit Bacterial Filter with Luer lock port Dead Space (ml) Resistance (cmho) Weight (g) BFE Efficiency VFE Efficiency Water Trap, Y Type, OD: mm Silicone Straight Connector / /15F FL-7011 ml 0 L/min L/min g >99.999% > % /15F FL-701 7ml 0 L/min L/min g >99.999% > % Expiratory Bacteria Filter, / BFE Efficiency VFE Efficiency WT WT NA HEPA Reusable Durable Water Trap Kit Disposable FL-7000 Reusable FL Disposable >99.99% >99.99% Water Trap, OD: mm Silicone T Connector / /15F FL-7011(W/ Luer) FL-701(W/O Luer) Tidal Volume range (ml) Dead Space (ml) Moisture Output Resistance (cmho) ml mg/l at TV 500ml 0 L/min L/min 1.5 Weight (g) BFE Efficiency VFE Efficiency 9.51g >99.99% >99.99% 9.g >99.99% >99.99% Device Besmed Best Choice for Care.

7 Device Accessories Test Lung, 1000ml Specification Compliance 0ml/cmH O (ref) Resistance 5.0cmH O/L/sec (ref) Tidal Volume 0-600mL (with 1L bag) Weight 05 grams Dimension 9 X 100 X mm Connector 15mm O.D. TL-9100 TL-910 BR-61 Test Lung, 1000ml Test Lung, 1000ml Silicone Bag For Test Lung, 1000ml Test Lung, 50ml Specification Compliance <1 Vt=0mL Resistance <0 mbar/l/s Tidal Volume 0 ml Weight 5 grams Dimension 0 X 50 X 50 mm Connector 15mm O.D. TL-900 Test Lung, 50ml Test Lung, 0ml, for Neopuff Specification Tidal Volume 10mL TL-900 Test Lung, 0ml, for T-piece for Infant Resuscitator for Neopuff Aluminum Mount for device HC-7001 Aluminum Mount with two slide in for device TL-9100 TL-910 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES info@besmed.com 5

8 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES Reusable Breathing Circuit VENTILATOR Inspiration LEMO Heated Expiratory System Expiratory filter heater is a device to heat and remove microbiological and particles from the gases in the expiratory limb of breathing circuit. And prevent water condensation in expiratory limb of ventilator. Expiration Reusable Breathing Circuit Expiratory Filter Heater Page Durable Water Trap Air leakage free design. Standard or connector for adult, pediatric circuits. Durable material for resuage. 6 Besmed Best Choice for Care.

9 Reusable Breathing Circuit Reusable Breathing Circuit - Adult Ømm 1 Adult Ømm 5 60cm Type Non-Heated Wire Single Heated Wire Dual Heated Wire 1 15F/ Feature Silicone tube is applied for a smooth airflow for patient s safety Durable water trap for free leakage. Universal Catheter Mount for endotracheal tube or suction Two additional ports for pressure and temperature monitoring Silicone Circuit Anti-Slip design for easy attachment. Reusable Heated Wire Assembly Available for adult (Tube: ). * 1 * Reusable Y connector Two additional ports for pressure and temp monitoring or air delivery: 6M & 7.6F. Universal Fitting Universal Catheter Mount with endotracheal tube or closed suction catheter. 6 15F/ Patient Y Piece Chamber Tube NON-HEATED WIRE Inhale Exhale Water Trap SINGLE HEATED WIRE Inhale (Heated) Exhale (Non-Heated) Water Trap DUAL HEATED WIRE Inhale (Heated) Exhale (Heated) Water Trap 5 6 * * * * 1 * * 1 m W/ Port 60 cm cm cm Pcs 10 cm cm 1 Pc 10 cm 10 cm N/A CT-1 CT- CT-5 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES info@besmed.com 7

10 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES Accessories Reusable Catheter Mounts Silicone Tubing Reusable Water Traps WT-961 WT-96 A Tubing OD: 15mm OD: mm B 15F/ A B C CU CU CT-109 CT-108 CT o Swivel Reusable Y Piece Connectors CT-110 CT-10 /15F,, /15F,, W/ 7.6mm Port Reusable Heated Wire Assembly HC-7610 HC-760 HC-760 HC-760 Length: 1.0m Length: 1.m Length: 1.8m Length:.0m Suction Cap 60 o Swivel /15F C 15F/ /15F Reusable Breathing Circuit Tube CU CU-6850 CU-6850 CU CU-6860 CU mm Port LEMO Chamber 8 Besmed Best Choice for Care.

11 Reusable Breathing Circuit Accessories & Tubes Reusable Straight Connectors CT-18 CT-11 CT-17 Reusable Silicone Tubing, ID: mm CT-1000 CT-1000 CT CT-1006 CT CT-1001 CT CT m 0.0m 0.60m 0.60m (Elbow connector) 0.90m 1.m 1.5m 1.8m PVC Smoothbore ID: 15mm CT-1085 CT CT CT CT Length 1.0m 1.m 1.5m 1.8m.0m Reusable CPAP Tubing with TPR Cuffs, ID: mm CT-1085 CT-1087 CT CT , 15F/, 15F/, 15F/ ID: mm CT-1087 CT CT CT CT m 1.5m 1.8m.0m 15F/ 15F/ 15F/ 1 CT-1006 Elbow connector BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES info@besmed.com 9

12 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES Heated Wire - Neonate Ø10mm Infant Ø1mm 60cm 1 5cm M 6M Patient Y Piece 180cm M 6M 15F W/Suction Port Pressure Line 180cm 5cm 110cm SINGLE HEATED WIRE 15F 1F Inhale (Heated) cm 90cm 60cm Exhale (Non-Heated) cm 5 Chamber Tube 60 cm Water Trap 1 Pc Component Packet 1M 1F 15F/ 1F 7.6M /15F 10F 7 1M 1F M 6M 1F 7.6M /15F 10F 6 Limb Type Single Neonate Ø10mm CT-191 CT-19 Infant Ø1mm CT-191 CT-19 60cm 1 5cm M 6M 180cm M 6M Patient Y Piece 15F W/Suction Port Pressure Line 180cm 5cm 110cm 1F DUAL HEATED WIRE 15F Inhale (Heated) cm 150cm 5 Exhale (Heated) 150 cm Chamber Tube 60 cm 7 Component Packet 1M 1F 15F/ 1F 7.6M /15F 10F 1M 1F M 6M 1F 7.6M /15F 10F Disposable Breathing Circuit 6 Limb Type CT-19 Neonate Ø10mm CT-19 Dual CT-19 Infant Ø1mm CT Besmed Best Choice for Care.

13 Disposable Breathing Circuit Heated Wire - Adult Ømm 15F Limb Single 15F cm 1 60cm 1 0cm Type Adult Ømm 0cm cm 150cm 10cm cm 150cm 150cm 75cm Feature Spiral heated wire provides proper distribution of air. Auto-feeding chamber with high efficiency without disconnection while the patient is under treatment. Single patient use, up to 7 days application. Resistance, compliance and leakage conform to ISO-567 for breathing circuit. Humidity output of circuit and chamber conforms to ISO Patient Y Piece Pressure Line SINGLE HEATED WIRE Inhale (Heated) 150 cm Exhale (Non-Heated) cm Chamber Tube 60 cm Water Trap 1 Pc Patient Y Piece Pressure Line DUAL HEATED WIRE Inhale (Heated) Exhale (Heated) Chamber Tube 15F 00cm CT-190 CT F 00cm 150 cm cm 60 cm BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES Limb Type Dual Adult Ømm CT-1901 CT-190 info@besmed.com 11

14 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES Ventilator Circuit Feature mm Breathing System for Dräger Oxylog 000, 000, 000 Plus. Universal catheter mount with suction tube, flower sensor, exhalation valve with double-function-port for monitoring oxygen or press with a convertor. IPPB Breathing System for Adult 15cm 100cm 180cm 150cm 110cm Indication IPPB is designed for use with Intermittent Positive Pressure Breath machines for spontaneously breathing system to assist lung expansion, deliver aerosol medication or to assist ventilation. Feature Ideal for most common IPPB treatment. Manifold with effective valve to get response. Nebulizer delivers aerosol particle size <5 MMAD. Disposable Breathing Circuit CODE CT-111 Patient Y Piece 15F/ Manifold -Way W/ 6mm L Port Flow Sensor 1 Pc Disposable Tubing Main Limb Cuff 150cm Pressure Line 180cm CODE CT-115 Mouthpiece & Tube 15 cm Manifold -Way W/ 6mm L Port Nebulizer 0cc Disposable Tubing Main Limb Cuff 100cm Control Line 110 cm 1 Besmed Best Choice for Care.

15 Disposable Breathing Circuit Ventilator Circuit Single Breathing System 1.8m with Exhalation Tube, Exhale Elbow Control Line Single Breathing System 1.8m with Exhalation Tube, Pressure Line, Exhale Elbow Control Line Pressure Monitoring Line Single Breathing System 1.8m with Exhalation Tube, Pressure Line, Exhale Elbow Control Line Pressure Monitoring Line CODE CT-110 Patient Y Piece 15F/ Manifold -Way Single Limb Disposable Circuit Main Limb 150cm Control Line 180cm CODE CT-11 Patient Y Piece 15F/ Manifold -Way Dual Limb Disposable Circuit Main Limb 150cm Pressure Line 180cm Control Line 180cm CODE CT-110 Patient Y Piece 15F/ Manifold -Way W/ 6mm L Port Dual Limb Disposable Circuit Main Limb 150cm Pressure Line 180cm Control Line 180cm BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES info@besmed.com 1

16 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES Breathing System with Water Trap 1 Adult Ømm Type Adult Ømm Child Ø15mm 1 Patient Elbow Water Trap * 1 * 1 * * 1 * 1 * 1 * 1 * 1 * 1 * * 1 * 1 * 1 * 1 * 1 * 1 * 1 * * 1 * 1 * 1 * 1 * 1 * 1 * * 1 * 1 * 1 * 1 * 1 1. Elbow Connector. Parallel Connector. Bi-Wya Connector. 75cm Tube 5. Water Trap 6. Chamber: 5cm Tube cm Tube 8. CT-18 Straight Connector ; /15F 9. Hanging (PO / PO ) 10. Connector / Type Child Ø15mm 1 * 1 * 1 * * * 1 * 1 * 1 * * * 1 * 1 * 1 * * * 1 * 1 * 1 * * * 1 * 1 * 1 * * * 1 * 1 * 1 * * * 1 * 1 * 1 * * * 1 * 1 * 1 * * * Patient Elbow Water Trap 10 * * * * * 1 * 1 * * 1 * 1 * * 1 * 1 * 1 * 1 * * 1 * 1 * 1 * 1 * * 1 * 1 * * 1 * 1 * * 1 * 1 * 1 * 1 * * 1 * 1 * 1 * 1 * 15F/ Parallel or Bi-Wye 1 Pc CT-10 CT-50 CT-1710 CT F/ Parallel or Bi-Wye Pcs CT-90 CT-790 CT-91 CT-791 CT-1790 CT CT-1791 CT Elbow Connector. Parallel Connector. Elbow Connector W/Luer-Lock. Bi-Wya Connector 5. 75cm Tube 6. Water Trap 7. Chamber: 5cm Tube 8. CT-18 Straight Connector ; /15F 9. Hanging (PO / PO ) 10. FL-7011 Filter 11. HC-718 Chamber (Auto-feeding) 1. Connector / Disposable Tubing Inhale Exhale Chamber Tube Disposable Tubing Inhale Exhale Chamber Tube Disposable Breathing Circuit 150 cm cm 5 cm cm cm 5 cm 1 Besmed Best Choice for Care.

17 Disposable Breathing Circuit Flow Sensor for Hamilton Ventilator Indication Flow Sensor is the centerpiece of ventilator device which provides a better assessment with precise tide volume, flow and pressure of patient s lung condition for professional s evaluation. Function Compatible with breathing circuit in use of Hamilton intensive care Ventilators, Hamilton-G5, GALILEO, Hamilton-C, RAPHAEL, AMADEUS, VEOLAR device. Feature Roundish structure of pressure-flow location to assure the proximal flow measurement. Tested with Hamilton-G5 Flow Sensor Calibration, Tightness P/V tool <150ml. Sensor Connector: /15F, in accordance with ISO Single patient use to reduce risk of Ventilator Associated Pneumonia (VAP). Applicable for Adult. PO-8579 Flow Sensor for Hamilton Ventilator Application 1 - Breathing Circuit Application - Heated Wire Application - Dual Limb Circuit Patent no.tm M56799 / DE U1 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES info@besmed.com 15

18 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES Disposable Catheter Mounts A Tubing Smoothbore Tubing 15F Extensible Tubing 15F B 15F/ A B C CU-6800 CU-6800 CU-6810 CU-680 CT-109 CT-108 CT o Swivel Suction Cap 60 o Swivel C 15F/ Disposable Breathing Circuit CU-6807 CU-6808 CU-6809 CU-6807 CU-6808 CU-6809 CU CU CU CU CU CU CU CU CU CU-680 CU-6805 CU-6806 CU-680 CU-6805 CU-6806 CU-6800 CU CU CU-6890 CU CU CU-6880 CU CU Besmed Best Choice for Care.

19 Disposable Breathing Circuit Disposable Catheter Mounts A Tubing Corrugated Tubing B CU-6800 CU-6800 CU-6810 CU-680 CT-109 CT-108 CT o Swivel B 15F/ Suction Cap 60 o Swivel Manifold Exhalation Valve CT-110 W/ m Exhale Port CT-110 W/ Exhale Cap A C C 15F/ W/ 6mm L Port W/O 6mm L Port CT-1150 W/ m Exhale Port CU-6801 CU-680 CU-680 CU-6801 CU-680 CU-680 CU CU-6800 CU-6800 CU CU-6890 CU-6890 CT Way Manifold Exhalation Valve BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES info@besmed.com 17

20 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES Disposable Water Traps Bi-Wye Water Traps WT-9611 OD: 15mm WT-961 OD: mm Parallel Water Traps WT OD: 15mm WT-9611 OD: mm Parallel Water Traps WT OD: 10mm WT-9651 OD: 1mm Tracheal HME with Oxygen Port 15F 6mm FL-7015 Tidal Volume range (ml) Dead Space (ml) 1.5ml Moisture Output 9mg/L at TV 500ml Resistance (cmho) 0 L/min 0.6 Weight (g) 6.8g Tracheal HME with Suction Port Suction Port 6mm FL-7016 Tidal Volume range (ml) Dead Space (ml) ml Disposable Breathing Circuit Tracheal HME with Suction Port Suction Port 6mm FL-7018 Suction port 5.0mm (White Cap) FL-7019 Suction port.0mm (Blue Cap) FL-7010 Suction port.0mm (Yellow Cap) 18 Besmed Best Choice for Care.

21 Disposable Breathing Circuit HMEF & HME /15F / /15F / /15F / /15F Tidal Volume range (ml) Dead Space (ml) Moisture Output Resistance (cmho) Weight (g) BFE Efficiency VFE Efficiency Tidal Volume range (ml) Dead Space (ml) Moisture Output Resistance (cmho) Weight (g) BFE Efficiency VFE Efficiency Tidal Volume range (ml) Dead Space (ml) Moisture Output Resistance (cmho) Weight (g) BFE Efficiency VFE Efficiency Tidal Volume range (ml) Dead Space (ml) Moisture Output Resistance (cmho) Weight (g) BFE Efficiency VFE Efficiency HMEF FL-7011 HMEF W/Luer lock port ml 9mg/L at TV 500ml 0 L/min.6 60 L/min g >99.999% > % FL-701 HMEF ml 8mg/L at TV 500ml 0 L/min L/min g >99.999% > % FL-701 HMEF W/Luer lock port ml 8mg/L at TV 500ml 0 L/min L/min g >99.999% > % FL-70 HMEF ml 9mg/L at TV 500ml 0 L/min L/min..50g >99.999% > % HME FL HME W/Luer lock port ml 9mg/L at TV 500ml 10 L/min g FL-7011 HME ml 8mg/L at TV 500ml 0 L/min L/min.0 7.0g FL-7011 HME W/Luer lock port ml 8mg/L at TV 500ml 0 L/min L/min g FL-701 HME ml 9mg/L at TV 500ml 0 L/min L/min 1..0g BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES info@besmed.com 19

22 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES HMEF & HME / /15F / /15F F 15F Tidal Volume range (ml) Dead Space (ml) Moisture Output Resistance (cmho) Weight (g) BFE Efficiency VFE Efficiency Tidal Volume range (ml) Dead Space (ml) Moisture Output Resistance (cmho) Weight (g) BFE Efficiency VFE Efficiency Volume (ml) Vt up to Resistance (cmho) Weight (g) HMEF FL-701 HMEF W/Luer lock port ml 9mg/L at TV 500ml 0 L/min L/min.5.50g >99.999% > % FL-701 Angled HMEF W/Luer lock port ml 8mg/L at TV 500ml 0 L/min L/min g >99.99% >99.99% FL-701 Artificial Nose 85ml 1500ml 0.5 L/min L/min g HME Disposable Breathing Circuit FL-7011 HME W/Luer lock port ml 9mg/L at TV 500ml 0 L/min L/min 1..50g FL Angled HME W/Luer lock port ml 8mg/L at TV 500ml 0 L/min L/min g 0 Besmed Best Choice for Care.

23 Neonatal Care Bubble CPAP System Air-Bubbler TM Bubble CPAP Kit inflow TM Hi-iNFLOW TM Infant Interface T-piece for Infant Resuscitator Accessories

24 REPLACE IF WATER LEVEL ABOVE THIS LINE FU LO BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES Bubble CPAP System Air-Bubbler 1 Aluminum Mount for device Heated Wire Circuit Inhale (Heated) 110 cm Exhale (Non-Heated) 150 cm CT-1950 For inflow CT-190 FU LO 1 Pressure Manifold Humidification Chamber Auto Respiratory Humidifier Besmed Best Choice for Care.

25 WT-966 Indication provides CPAP to spontaneously breathing neonates and infants who require breathing support because of prematurity or any other conditions CPAP prescribed by doctors. allows airway pressure to be set easily with bubble CPAP devices. Function provides a proven method of delivering -10cm H O for bubble CPAP for use with infants weighing<10kg. The CPAP is adjustable from to 10cm H O with gas flow from 1 to 1L/PM Transparent bottle allows the water level to be observed without disruption. Feature Most unique and compact bubble generator with patent pending. Vertical swivel button to fix up the pressure as per patient s demand by doctors/nurses. Specific indication to avoid any improperly operational risk Automatic Min/Max water line assures appropriate water being filled up. Specification Gas Inlet Connector Gas Flow Range Adjustable Range Accuracy Low Water Capacity Medium High Size Weight Vertical swivel from to10 to fix up the pressure as per patient s demand. / connector -15 LPM -10cm H O ±1cm H O 50ml 80ml 00ml 11.5 x 11.5 x 5 cm 157 g 60 o swivel 60 o swivel to connect expiratory circuit with 15F/ connector. Water adjustment port enables users without disconnecting circuit. Patent Pending US, EU, TW, CN Automatic Min/Max water line assures appropriate water being filled up. BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES info@besmed.com

26 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES Bubble CPAP Kit Bonnet Nasal Prongs Sampling Line Connector Kit Collapsible Tubing XS XS S S M M M XS XS S S M M M Bonnet net Nasal Prongs Type Sampling Line Bonnet Collapsible Tubing Nasal Prongs CA-6000 CA-6001 CA-600 CA CA CA CA-0011 CA-0011 CA-0011 CA Size XS S M <700 grams grams grams Less than 600 grams Less than 700 grams 700 to 100 grams 100 to 000 grams 000 to 000 grams over 000 grams over 5000 grams Single patient use device intended for use with neonates, infants and children under 10Kg requiring a nasal prong interface during intermittent or continuous gas flow therapy in the hospital critical care unit. Corrugated Tubing CA-600 CA-610 CA-611 CA-61 CA-61 CA-61 CA-615 CA-600 CA-610 CA-611 CA-61 CA-61 CA-61 CA-615 Bubble CPAP Kit Includes: Bonnet Nasal Prongs Sampling Line Connector Kit Collapsible Tubing Corrugated Tubing 10cm Besmed Best Choice for Care.

27 Bubble CPAP Kit - inflow TM inflow TM Tube CA-6700 Inspiration Expiration inflow TM with Nasal Mask Medical grade soft silicone ensures comfort. Optimize anatomical shape. Ideal contour of nasal size to fit the patient s nose. Single patient use. Available sizes: S/M/L. inflow TM with Nasal Prongs Medical grade silicone, soft-touch on nares. Anatomical curvature snugly fits patient s nares. Septum cut-away design to help prevent septum injury. Single patient use. Available sizes: XS/S/M/L/XL Heated Wire for inflow 5cm M 6M 180cm M 6M 10M 10M 10F 10F 110cm 150cm Besmed inflow TM provides a complete solution for infant CPAP system. It can be compatible with all flow driver and humidifier in the neonatal ICU. It consists of the Nasal Prongs, Mask, Nasal tubing and Bonnet. Feature Low dead space. Easy to use. Light weight and flexible tubing. Compatible with nasal prongs or mask. Two positive angles for prongs or masks placement. CODE Inhale (Heated) Exhale (Non-Heated) Pressure Line Type 5 o 60 o CT cm 150 cm 180 cm BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES info@besmed.com 5

28 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES Nasal CPAP Kit - Hi-iNFLOW TM Hi-iNFLOW TM Tube CA-670 Heated Wire for Hi-iNFLOW 5cm 5cm Pressure Line Drive Line Exhaust Tube Hi-iNFLOW TM with Nasal Mask Medical grade soft silicone ensures comfort. Optimize anatomical shape. Ideal contour of nasal size to fit the patient s nose. Single patient use. Available sizes: S/M/L. 110cm 180cm 56cm Besmed Hi-iNFLOW TM provides a complete care solution for infant CPAP. It fits SiPAP device in the neonatal ICU. It consists of the Nasal Prongs or Mask, Nasal tubing and Bonnet. It is intended to be used for the administration of continuous positive airway pressure (CPAP) on continuously monitored neonatal and infant patients in the hospital/institutional environment. Indication Abnormalities on physical examination Deteriorating arterial/capillary blood gas valves Atelectasis Weaning/post-extubation support Feature Low dead space. Light weight and flexible tubing. Compatible with nasal prongs or masks. Hi-iNFLOW TM with Nasal Prongs Medical grade silicone, soft-touch on nares. Anatomical curvature snugly fits patient s nares. Septum cut-away design to help prevent septum injury. Single patient use. Available sizes: XS/S/M/L/XL CODE Inhale (Heated) Pressure Line Type CT-19 W/O Chamber CT-195 W/ Chamber 110 cm 180 cm 6 Besmed Best Choice for Care.

29 Infant Interface Besmed develops the infant interface for use with the Bubble CPAP System, Nasal CPAP and non-invasive support system. Feature Medical grade silicone material. BPA Free, DEHP Free, Phthalate Free and Latex Free Material. Anatomically designed. Ideal size and depth for selection. Available five sizes of prongs and three sizes of mask. Interchangeable with prongs or masks. Bonnet Type XS S M L Nasal Prongs Nasal Mask Correct Size Size XS S M L XS S M L XL S M L <700grams ( cm) grams (17.6-0cm) grams (0-5cm) grams (>5cm) Medical grade silicone Medical grade silicone Medical grade silicone Medical grade silicone Medical grade silicone Medical grade silicone Medical grade silicone Medical grade silicone Size indication Prong & Mask Size Guide CA-6006 Use size meter to select right size to promote ideal fit to optimize therapy delivery. CA-6701 CA-670 CA-670 CA-670 CA-6800 CA-6810 CA-680 CA-680 CA-680 CA-6811 CA-681 CA-681 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES info@besmed.com 7

30 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES T-piece for Infant Resuscitator for Neopuff 15F #00 # cm Feature Designed PEEP Valve to provide a comfortable and controlled hold of the circuit. A duckbill port is also incorporated for appropriate application, such as suctioning and surfactant delivery. Mask size 000, 00 packed for easy selection. Heated Wire for Dräger Babylog F 10F 10F 5cm 1F 60cm Accessories Pressure Manifold CT-150 Relief Valve 1.5cmH O, Tube, T-connector, Cap 90cm 10F 110cm Relief Valve RE cmH O 60cm 10M 10M 10F 10F CODE CT (without mask) CT (with masks size000, 00) Patient 15F Length 1.5m CODE Patient Y Piece SINGLE HEATED WIRE 15F W/Suction Port Inhale (Heated) cm Exhale (Non-Heated) cm Water Trap Disposable High Flow Connector CT-160 1M 1F/ Orange restrictor for use with 1mm disposable circuit for SLE5000. CT Pc Disposable Water Trap WT WT-9651 OD:10mm OD:1mm 8 Besmed Best Choice for Care.

31 Anesthesia Circuit Duo-Limb Circuit Anesthesia Circuit - Mapleson Circuit - Child Ø15mm - Adult Ømm - Extensible Circuit - Entonox Circuit with Mouthpiece Accessories

32 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES Duo-Limb Circuit Feature Inspiration + Expiration in one tube reduces its weight. Light weight reduces torque on the patient s airway while transporting. Applicable for all anesthetic and breathing devices. Single Patient Use, Latex Free. Length 1.5m 15F/ Inspiration.0m.0m 1 Length L Expiration 90cm 1 Latex Free Bag, /15F 1. Expandable Extra Limb 0.9m. Breathing Bag L, Latex Free. Straight Connector, /15F Patient Y Piece Available for Accessories Duo-Limb Tubing, Cuff Main Tube 150cm / 00cm 00cm Exhale Extendable Tubing 15F/ W/Luer Lock Adult / Child Option 5cm CT CT CT-1170 CT-1171 CT CT Besmed Best Choice for Care.

33 Anesthesia Circuit - Child 15F/ Anesthesia Circuit - Adult Mapleson C 15F/ Mapleson D Basic & Deluxe Bain Coaxial System 15F/ 0.5L Mapleson F Jackson Rees Modification 15F/ Inspiration 0.5m L Expiration 1.8m 15F L 15F 15F 1.8m 0.5L Open Tail 15F CODE Patient APL Valve 15F/ 0cm H O Length 1.8m Reservoir Bag 0.5L CODE Patient APL Valve CT-150 CT F/ 0cm H O Length 1.8m Reservoir Bag 0.5L W/ Open Tail CODE Patient APL Valve 15F/ 60cm H O Length 1.8m Reservoir Bag L CODE Patient APL Valve CT-1500 CT (1.5m) CT (.0m) 15F/ 60cm H O Length 1.5m,.0m Reservoir Bag L BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES info@besmed.com 1

34 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES Child Ø15mm Patient Parallel Elbow 1 Bi-Wye 1L 1L Latex Bag Latex Free Bag Type Length 1 1.m 1.5m Parallel 1.8m.m 1.m Bi-Wye 1.5m 1.8m.m 1. Breathing Bag 1L, Latex Bag (Gray). Breathing Bag 1L, Latex Free Bag (Green) 15F/ W/ Luer CT-171 CT-17 CT-17 CT-171 CT-17 CT-17 CT-171 CT-17 CT-17 CT-1751 CT-175 CT-175 CT CT-1770 CT-1770 CT CT-1771 CT-1771 CT-1771 CT-177 CT-177 CT-1771 CT-177 CT-177 Besmed Best Choice for Care.

35 Adult Ømm Patient Parallel Elbow 1 Bi-Wye L L Latex Bag Latex Free Bag Type Length 1 1.m Parallel 1.5m 1.8m 1.m Bi-Wye 1.5m 1.8m 1. Mask #5. Breathing Bag L, Latex Bag (Gray). Breathing Bag L, Latex Free Bag (Green). Bacterial Filter 15F/ W/ Luer CODE CT-0 CT-08 CT-1 CT-6 CT-8 CT-50 CT-5 CT-5 CT-60 CT-6 CT-70 CT-7 CT-06 CT-78 CT-80 CT-711 CT-71 CT-71 CT-7 CT-717 CT-71 CT-70 CT-7 CT-75 CT-76 CT-71 CT-7 CT-7 CT-76 CT-77 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES info@besmed.com

36 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES Extensible Circuit - Adult Ømm Patient Elbow 1 1.5m L Latex Bag 15F/ Type Length 1 1.8m Parallel.0m.0m 1. Tubing 1.5m. Breathing Bag L, Latex Bag (Gray). Straight Connector 15F/ Extensible Circuit - Child Ø15mm Patient Elbow 1 90cm 1L Latex Bag 15F/, Type Length 1 1.8m Parallel.0m.0m 1. Tubing 0.9m. Breathing Bag 1L, Latex Bag (Gray). Straight Connector 15F/, 15F/ W/ Luer CT-009 CT-010 CT-011 CT-01 CT-01 CT-01 CT-015 CT-0 CT F/ W/ Luer CT-1711 CT-1715 CT-1717 CT CT CT CT CT CT Besmed Best Choice for Care.

37 Entonox Circuit with Mouthpiece Low Resistance Extensible Tube with One Way Valve and Detachable Scavenging Tube Valve ID: mm Valve Accessories APL Valve CT-1550 CT CT-1560 CT cm H O 60cm H O 0cm H O with T connector 60cm H O with T connector Expiration Inspiration 15F/,, CODE Patient Inspiratory HMEF Disposable Tubing Inhale Exhale 0cm H O 60cm H O CT-019 Valve Tee with Mouth Piece 1Pc 00 cm 00 cm 0cm H O with T connector 60cm H O with T connector BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES info@besmed.com 5

38 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES Accessories Silicone Breathing Bag BR L BR L BR-650.0L BR-650.0L Latex Free Rubber Bag BR L BR L BR-60.0L BR-60.0L Latex Rubber Bag BR L BR L BR-610.0L BR-610.0L Latex Rubber Bag With Open Tail BR L BR L OPEN 6 Besmed Best Choice for Care.

39 Accessories Y Piece Connectors T Spring Connectors Elbow Connectors Straight Connectors Tubing & Accessories BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES

40 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES Y Piece Connectors Parallel - mm 15F/ W/ 7.6mm Port W/ Port & L Connector Swivel Swivel W/ Port 7.6mm CT-110 CT-11 CT-11 CT-110 CT-11 Parallel - 15mm CT-1110 Bi-Wye - mm CT-10 Bi-Wye - 15mm CT F/ 6mm W/ 7.6mm Port W/ Port & L Connector 15F/ CT mm CT-111 6mm W/ 7.6mm Port W/ Port & L Connector 15F/ CT-1 7.6mm CT-1 6mm W/ 7.6mm Port W/ Port & L Connector CT mm CT-11 6mm 8 Besmed Best Choice for Care.

41 Y Piece Connectors For Heating Wire ID: 10mm ID: 1mm CT-110 CT-11 T Spring Connectors W/ Valve mm 18F 18F CT-1 CT-1 W/ Port /15F 18F 18F CT-16 CT-15 15mm W/ Port 15F 15F 18F 18F CT-11 CT-1 ID: 1mm HC-7008 Straight Connectors Adjustable Cap for Anesthesia Circuit W/ mm Port CT-15 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES info@besmed.com 9

42 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES Elbow Connectors Tubing: mm W/O Port Luer Lock 15F/ 15F/ CU-6810 CU-6806 Tubing: 15mm W/O Port Luer Lock 15F/ 15F/ CU-6810 CU-680 Tubing: 15mm 10M 6M 10M 6M 15F/ 15F/ CU-6809 CU-6811 Straight Connectors Stripe W/ Port CU M W/ Luer Lock 15F/ CU-681 Grip CT-110 CT-110 CT-1106 CT Besmed Best Choice for Care.

43 Straight Connectors 15F/, 15F/ W/Port, 15F/ W/O Port 6mm/15F Swivel Connector (/15F) /15F CT-110, CT-151 W/ 6mm Port W/ 10mm Port 15F/ CT-17 CT-18 CT-10 CT-105 CT-159, 15F/ W/ 6mm Port W/ 10mm Port 6mm 6mm CT-111 CT-15 /15F /15F /15F /15F 10mm 10mm CT-11 6mm Port W/ Luer Lock CT-155 6mm Port W/ Luer Lock BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES CT-15 CT-15 CT

44 BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES Straight Connectors 1 15F 15F 10M 15F 15F Tubing: 15mm 7.6M CT-111, 15F CT-11, 15F CT-11 10M, 7.6M 1M 10M 8.5M 6.0M 1M 10M 10M 10M / /15F /15F 8M CT-100, CT-101, 1M CT-10, 10M CT-10, 8.5M CT-10, 6.0M 1.9M 1.9M 1M 10M 7.6M 6M 15F 15F 15F 15F 15F 15F CT-106, 1.9M CT-105, 1.9M CT-1, 1M CT-10, 10M W/ 7.6mm Port CT-1, CT-1 15F, CT-1,1M CT-1, CT-115, CT-119, / CT-11, /15F CT-10, /15F 1M 10M 15F 15F 1M 10M 7.6M 6M CT-1501, 10M CT F, 10M CT-150, 10M CT-16 15F, CT-15 15F, 15F CT-1 15F, 1M CT-1 15F, 10M.8M CT-1, CT-1, 1M CT-1, 10M CT-117, 15F/ CT-118 8M,.8M 5 CT-101, 7.6M 5 CT-1 15F, 7.6M 6 CT-100, 6M 6 CT-11 15F, 6M Besmed Best Choice for Care.

45 Tubing & Accessories Corrugated Tubing CT m, ID: mm CT m, ID: 10mm CT m, ID: 1mm CT m, ID: 15mm Extensible Tubing Length 0.5m 0.90m 1.m 1.5m 1.8m.0m ID: 10mm CT-1068 CT CT CT CT CT-1069 ID: 15mm CT-1065 CT CT-1066 CT CT CT ID: mm CT CT-106 CT-106 CT-1068 CT-106 CT-1065 Tube Hanger PO F PO F PO F Tube Clip Tube Ring PO cm/CUFF BREATHING CIRCUIT NEONATAL CARE ANESTHESIA CIRCUIT ACCESSORIES PO-8571 PO-857 PO-8570 PO

46 Besmed Best Choice for Care.

47 5 Index Page Page Page CA CA CA CA-0011 CA-0011 CA-0011 CA CT-1000 CT-1000 CT CT CT-1001 CT CT CT-1006 CT CT-1080 CT-1080 CT-1071 CT CT-106 CT-106 CT-1068 CT-106 CT-1065 CT-1065 CT CT-1066 CT CT CT CT-1068 CT CT CT CT CT-1069 CT-1085 CT-1087 CT-1080 CT-1085 CT CT CT CT CT CT-110 CT CT-111 CT-11 CT-115 CT-110 CT-110 CT-1150 CT-1170 CT CT CT CT CT-1170 CT-1171 CT CT CT-1110 CT-111 CT-111 CT-110 CT-11 CT-11 CT-110 CT-11 CT-110 CT-10 CT-110 CT-11 CT-11 CT-10 CT-1 CT-1 CT-110 CT-11 CT-11 CT-1 CT-1 CT-1 CT-15 CT-16 CT-150 CT-110 CT-110 CT-110 CT-1106 CT-100 CT-101 CT-10 CT-105 CT-106 CT-110 CT-111 CT-11 CT-11 CT-11 CT-1 CT-1 CT-1 CT-15 CT-16 CT-17 CT-18 CT-10 CT-1 CT-100 CT-101 CT-10 CT-10 CT-10 CT-105 CT-111 CT-11 CT-11 CT-11 CT-115 CT-1 CT-117 CT-118 CT-119 CT-10 CT-1 CT-1 CT-1 CT-17 CT-18 CT-1 CT-1 CT-1 CT-15 CT-151 CT-15 CT-15 CT-15 CT-155 CT-156 CT-159 CT-160

48 Besmed Best Choice for Care. 6 Index Page Page Page CT-1501 CT-150 CT-150 CT CT-1500 CT CT-150 CT-150 CT-1550 CT CT-1560 CT CT-009 CT-010 CT-011 CT-01 CT-01 CT-01 CT-015 CT-0 CT-017 CT-019 CT-10 CT-06 CT-08 CT-1 CT-0 CT-6 CT-8 CT-50 CT-5 CT-5 CT-60 CT-6 CT-70 CT-7 CT-78 CT-80 CT-90 CT-91 CT-1 CT- CT-5 CT-50 CT-70 CT-711 CT-71 CT CT-7 CT-717 CT-71 CT-7 CT-75 CT-76 CT-71 CT-7 CT-7 CT-76 CT-77 CT-790 CT-791 CT-1710 CT-1711 CT-1715 CT-1717 CT CT CT CT CT CT CT-171 CT-17 CT-17 CT-171 CT-17 CT-17 CT-171 CT-17 CT-17 CT-1751 CT-175 CT-175 CT-1790 CT-1791 CT-1750 CT CT-1770 CT-1770 CT CT-1771 CT-1771 CT-1771 CT-177 CT-177 CT-1771 CT-177 CT-177 CT CT CT-1901 CT-190 CT-190 CT-190 CT-191 CT-19 CT-19 CT-19 CT-190 CT-19 CT-1950 CT-195 CT-191 CT-19 CT-19 CT-19 CT-190 RE-105 BR-6105 BR-6110 BR-610 BR-610 BR-605 BR-610 BR-60 BR-60 BR-61 BR-6505 BR-6510 BR-650 BR-650 BR-6805 BR-6810 CA-6000 CA-6001 CA-600 CA-6006 CA-600 CA-610 CA-611 CA-61 CA-61 CA-61 CA-615

49 7 Index Page Page Page CA-600 CA-610 CA-611 CA-61 CA-61 CA-61 CA-615 CA-6700 CA-6701 CA-670 CA-670 CA-670 CA-670 CA-6800 CA-6810 CA-6811 CA-680 CA-681 CA-680 CA-681 CA-680 CU CU-6800 CU-6800 CU-6800 CU CU CU CU CU CU-6810 CU-6810 CU-680 CU-6806 CU-6808 CU-6809 CU-6811 CU-681 CU-6801 CU-680 CU-680 CU-680 CU-6805 CU-6806 CU-6807 CU-6808 CU-6809 CU CU-680 CU-680 CU-680 CU-6805 CU-6806 CU-6807 CU-6808 CU-6809 CU CU-6850 CU-6850 CU CU-6860 CU-6860 CU-6880 CU CU CU CU CU CU CU-6890 CU-6890 CU-6890 CU CU CU CU CU FL FL-7000 FL FL-7011 FL-7011 FL-7011 FL FL-7011 FL-701 FL-701 FL-701 FL-7015 FL-7016 FL-7018 FL-7019 FL-7010 FL-7011 FL-701 FL-7011 FL-701 FL-701 FL-701 FL-701 FL-70 FL-7000 FL HC-7001 HC-7008 HC-7010 HC-7011 HC-701 HC-701 HC-701 HC-7015 HC-70 HC-7017 HC-7018 HC-7100 HC-7 HC-718 HC-710 HC-700 HC-700 HC-700 HC-7600 HC-7610 HC-760 HC-760 HC-760 PO PO-8570 PO PO PO PO-8571 PO PO-8579 PO-857 TL-9100 TL-910 TL-900 TL-900 WT WT-9611 WT-9611 WT-961 WT-961

50 Index Page Page WT-96 8 WT WT-9600 WT WT-9600 WT-966 7WT NA 7WT NA Page 8 Besmed Best Choice for Care.

51

52 BESMED HEALTH BUSINESS CORP. Headquarters No., Lane 106, Wu-Kong rd Rd, Wu-Ku District, New Taipei City, Taiwan. 888 Tel: Fax: Web-site: Factories New Taipei City No. 5, Lane 1, Wu-Kong nd Rd, Wu-Ku District, New Taipei City, Taiwan. 888 Tel: Chiayi No., Dapumeiyuanqu rd Rd., Dalin Township, Chiayi County, Taiwan. 6 China No. 51 Mogan Shan Rd., Beilun, Ningbo, 15800, China Tel: Fax: nbo.sales0@besmed.com Copyright 018 Besmed Health Business Corp. All rights reserved Rev.1

Heated Wire - Neonate Ø10mm Infant Ø12mm

Heated Wire - Neonate Ø10mm Infant Ø12mm BREATHING CIRCUIT 01 Breathing Circuit Heated Wire Breathing Circuit Ventilator Circuit Breathing System Extensible Breathing System Coaxial Anesthesia Circuit Breathing System with Water Trap Anesthesia

More information

Neonatal Care. Besmed products are manufactured under international quality standards for medical device and marked with CE.

Neonatal Care. Besmed products are manufactured under international quality standards for medical device and marked with CE. NEONATAL CARE 01 Neonatal Care Besmed provides a solution for those patients with respiratory problems due to underdeveloped lungs and require breathing support because of prematurity or any other conditions

More information

CATALOGUE. Adult and Infant Respiratory Care Catalogue

CATALOGUE. Adult and Infant Respiratory Care Catalogue CATALOGUE Adult and Infant Respiratory Care Catalogue TABLE OF CONTENTS F&P 850 System Adult Care Adult Invasive Ventilation Adult Noninvasive Ventilation Adult Optiflow and Oxygen Therapy 6 F&P 850 System

More information

System Flow Chart. ventilation patient connection

System Flow Chart. ventilation patient connection System Flow Chart ventilation patient connection PATIENT CONNECTION VENTILATION STARTER KIT CONSUMABLES One selected kit may be ordered with every ventilator Note! Not all products listed here are available

More information

LISTADO DE CIRCUITOS DE PACIENTE

LISTADO DE CIRCUITOS DE PACIENTE CIRCUITOS DE ANESTESIA TIPO BAIN 8570073 ADU BAIN CIRCUIT, COAXIAL MAPLESON D CIRCUIT (1.5 M) 8570074 8570076 M1007452 8570075 M1035988 8570085 AESTIVA BAIN CIRCUIT, COAXIAL MAPLESON D CIRCUIT (1.5 M),

More information

Anesthesia Breathing Circuit

Anesthesia Breathing Circuit Anesthesia Breathing Circuit Instructions For Use: Peel off the bag, take out the product. Check all the connection parts of product, and tighten all the connection. Avoid leakage or loose when the product

More information

Hamilton accessories CONTENT

Hamilton accessories CONTENT Hamilton accessories CONTENT 2 I Breathing circuit set 3 I Breathing circuit set for HAMILTON-H900 3 I Flowsensor 4 I Expiratory valve & membrane 5 I CO2 6 I SpO2 6 I Nebulisering 7 I Masks 8 I High Flow

More information

DAR History page Anaesthesia Breathing Circuits page

DAR History page Anaesthesia Breathing Circuits page Breathing Circuits CONTENTS DAR History page 4 Anaesthesia Breathing Circuits page 8 Intensive Care Systems page 20 Breathing Systems for portable ventilators (single limb) page 36 Breathing Tubes page

More information

DAR: Our History page Anaesthesia Breathing Circuits page

DAR: Our History page Anaesthesia Breathing Circuits page Breathing Circuits CONTENTS DAR: Our History page 4 Anaesthesia Breathing Circuits page 8 Intensive Care Systems page 18 Breathing Systems for portable ventilators (single limb) page 34 Breathing Tubes

More information

Breathing Circuits. Product training

Breathing Circuits. Product training Breathing Circuits Product training Agenda Introduction to Breathing Circuits Anaesthesia Circuits Intensive Care Circuits Accessories 2 Covidien Introduction 3 Covidien What is a breathing circuit? In

More information

Advanced nasal CPAP system www.hamilton-medical.com/arabella Noninvasive, low-cost, effective and safe Neonatal nasal CPAP therapy Nasal CPAP therapy aims to support neonates, especially pre-term and

More information

KOALA. Disposable Adult Anaesthetic Circuits for Low Flow Anaesthesia KO.S5.22MM. Adult Anaesthetic Circuits. Medical Pty Ltd

KOALA. Disposable Adult Anaesthetic Circuits for Low Flow Anaesthesia KO.S5.22MM. Adult Anaesthetic Circuits. Medical Pty Ltd KOALA Disposable Adult Anaesthetic Circuits for Low Flow Anaesthesia Swivel wye Adult Anaesthetic Circuits KO.S5.22MM Adaptors for the Datex Ohmeda and GE Healthcare S/5 ADU Anaesthetic Machines Reusable

More information

INTENSIVE CARE VENTILATORS

INTENSIVE CARE VENTILATORS INTENSIVE CARE VENTILATORS iternis ADV INTENSIVE CARE VENTILATION FOR ALL PATIENT CATEGORIES Design Features HEYER iternis ADV s 12-inch touch-screen display combines comprehensive, easy-to-follow user

More information

Oxygen Therapy Devices

Oxygen Therapy Devices Oxygen Therapy Devices Oxygen Flow Meters with Heyer (SANS 1409) Connection Stock X0038 O2 Flow Meter Single with Heyer connection, ball and tube type (0-15 Litre) (Brass Base) X0039 O2 Flow Meter Double

More information

Respiratory. Products by Galemed

Respiratory. Products by Galemed Respiratory Products by Galemed MANUAL SILICONE RESUSCITATORS RESUSCITATION SETS DISPOSABLE RESUSCITATORS CPR POCKET RESUSCITATOR SILICONE MASKS GUEDEL AIRWAYS AEROSOL MASKS OXYGEN AND HI-OXYGEN OXYGEN

More information

Technical Data and Specifications

Technical Data and Specifications Technical Data and Specifications INTENDED USE Ventilator designed to provide Invasive and Non-invasive ventilation for the critical care management of adult, pediatric and neonate-infant (including premature)

More information

respiratory care aerosol therapy

respiratory care aerosol therapy ISSUE 2.0 respiratory care aerosol therapy & manual silicone resuscitators resuscitation sets disposable resuscitators cpr pocket resuscitator silicone masks guedel airways AEROSOL, OXYGEN & HI-OXYGEN

More information

INTRODUCTION. EN ISO 13485: AC:2012, EN ISO 9001:2008

INTRODUCTION.   EN ISO 13485: AC:2012, EN ISO 9001:2008 RESPIRATORY CARE ANESTHESIA CRITICAL CARE OXYGEN & AEROSOL THERAPY INTRODUCTION R-Vent Medical was founded in 15 with confidence and value. Located in Izmir, Turkey, R-Vent is a professional enterprise

More information

AUTOVENT 4000 VENTILATOR

AUTOVENT 4000 VENTILATOR OVERVIEW AUTOVENT 4000 Only properly trained and approved Escambia County Bureau of Public Safety Paramedics are to use the AutoVent 4000 ventilator manufactured by LSP to transport patients already on

More information

Mechanical Ventilation. Breathing Circuit and Accessories

Mechanical Ventilation. Breathing Circuit and Accessories Mechanical Ventilation Breathing Circuit and Accessories Breathing Circuit can be best described as the lifeline between the patient and the mechanical ventilator. It consists of various combinations of

More information

Oxygen Delivery Systems:

Oxygen Delivery Systems: Oxygen Delivery Systems: Oxygen Flow Meters with Heyer (SANS 1409) Connection: Stock Image X0038 O2 Flow Meter Single with Heyer connection, ball and tube type (0-15 Litre) (Brass Base) X0039 O2 Flow Meter

More information

General Anaethesia Airway

General Anaethesia Airway General Anaethesia Airway Breathing Systems Catalogue Breathing Circuits Face Masks Circuit Accessories Contents I Expandable Length Dual-Limb Circuits... 4 I Fixed Length Dual-Limb Circuits... 7 I Fixed

More information

PRODUCT CATALOG. Every Breath Matters. ARC Medical, Inc. circuitguard ThermoFlo PneumoniaCheck Cowan Road Tucker, GA 30084

PRODUCT CATALOG. Every Breath Matters. ARC Medical, Inc. circuitguard ThermoFlo PneumoniaCheck Cowan Road Tucker, GA 30084 PRODUCT CATALOG Every Breath Matters ARC Medical, Inc. circuitguard ThermoFlo PneumoniaCheck 4296 Cowan Road Tucker, GA 30084 Order Number: 800.950.ARC1 (2721) Fax: 404.373.8385 General Information Voice

More information

Intersurgical Product List

Intersurgical Product List Part# IS-0024030 IS-0028030 IS-0031030 IS-0035030 IS-0040030 IS-0060030 IS-0070030 IS-00996000 IS-00996001 IS-121040 IS-121045 IS-121050 IS-121055 IS-121060 IS-121065 IS-121070 IS-121075 IS-121080 IS-121085

More information

(Delivery System) Pocket Guide. Series 3 software

(Delivery System) Pocket Guide. Series 3 software (Delivery System) Pocket Guide Series 3 software Automated Pre-Use Procedure Integrated Pneumatic Backup INOMAX Delivery Transport Regulator/Cap Assembly Oxygen Dilution Chart INOMAX Cylinder Duration

More information

CPAP Devices - Masks - Accessories for respiratory assistance in CPAP

CPAP Devices - Masks - Accessories for respiratory assistance in CPAP Devices - Masks - Accessories for respiratory assistance in HAROL is one of the Italian companies leader in developing and selling systems, determining the most appropriate solutions for all your needs.

More information

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters SLE4000 Infant Ventilator with touch-screen operation When the smallest thing matters SLE4000 - The Total Solution for Conventional Infant Ventilation SLE is a world leader in the design and manufacture

More information

ANAPOD. The Perfect Solution in the O.R. Easy and Effective Management of Core Temperature. Heated Humidification System for Anesthesia

ANAPOD. The Perfect Solution in the O.R. Easy and Effective Management of Core Temperature. Heated Humidification System for Anesthesia ANAPOD TM Heated Humidification System for Anesthesia The Perfect Solution in the O.R. Easy and Effective Management of Core Temperature Improve Patient Comfort Minimize PONV Westmed_Anapod_prod_sht_133941.9.indd

More information

MANUAL RESUSCITATOR. EDM AN Eng. V

MANUAL RESUSCITATOR. EDM AN Eng. V MANUAL RESUSCITATOR 1 Fortune Manual Resuscitator Features: Equipped with pressure relief valve at 40 cmh 2 O with overridden mechanism. 2 different materials of Silicone, and PVC for reuse or disposable

More information

Aespire 7100 Essential performance Compact design

Aespire 7100 Essential performance Compact design GE Healthcare Aespire 7100 Essential performance Compact design Features Enhanced monitor integration capabilities with our Datex-Ohmeda Anesthesia Monitor and Compact Anesthesia monitor Lightweight and

More information

Sterile product catalogue

Sterile product catalogue Sterile product catalogue S Respiratory products and systems Quality, innovation and choice product catalogue sterile product range For over twenty five years Intersurgical has been supplying a wide range

More information

Straight & Straight-Tee

Straight & Straight-Tee Straight & Straight-Tee Adult 22mm Pediatric 15mm Neonate 10mm & 7.6mm Straight Connectors by Function ET Connectors Straight Tee Temp. Port Straight Tee 6M Port Straight Tee 4.3F Port Other Straight Tee

More information

First and Only Disposable Infant T-Piece Resuscitator. Because they are not miniature adults...

First and Only Disposable Infant T-Piece Resuscitator. Because they are not miniature adults... First and Only Disposable Infant T-Piece Resuscitator In-Line PIP Controller New Override Button Easier to Read Manometer New PIP Controller with Override Button allows clinicians to reach higher pressures

More information

(Delivery System) Pocket Guide Series 3 software

(Delivery System) Pocket Guide Series 3 software (Delivery System) Pocket Guide Series 3 software Automated Pre-Use Procedure Integrated Pneumatic Backup INOMAX Delivery Transport Regulator/Cap Assembly Oxygen Dilution Chart INOMAX Cylinder Duration

More information

Anesthesia Products & Circuits

Anesthesia Products & Circuits Anesthesia Products & Circuits Anesthesia Products & Circuits The world of anesthesia is the mysterious interplay of machinery, medicine and humanity, and the suspension of consciousness that allows the

More information

Operation and Maintenance of the EPV200 Portable Ventilator

Operation and Maintenance of the EPV200 Portable Ventilator Operation and Maintenance of the EPV200 Portable Ventilator 1 Applications of the EPV200 The EPV200 Portable Ventilator is a gas powered electronically controlled mechanical ventilator, designed to provide

More information

Giving neonates a future

Giving neonates a future Giving neonates a future Comprehensive respiratory support solutions Our heart beats for premature infants and newborns Our full commitment and knowledge are focused on lung-protective solutions for respiratory

More information

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR: PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: 1. **Identify and name the filters on the 7200ae. 2. **Explain how each filter is sterilized. 3. **Trace the gas flow through the ventilator

More information

Respiratory Care. and Aerosol Therapy

Respiratory Care. and Aerosol Therapy Respiratory Care and Aerosol Therapy MANUAL SILICONE RESUSCITATORS RESUSCITATION SETS DISPOSABLE RESUSCITATORS CPR POCKET RESUSCITATOR SILICONE MASKS GUEDEL AIRWAYS AEROSOL MASKS OXYGEN & HI-OXYGEN OXYGEN

More information

SLE5000 Infant Ventilator with HFO

SLE5000 Infant Ventilator with HFO SLE5000 Infant Ventilator with HFO When the smallest thing matters SLE5000 - The Total Solution for Infant Ventilation Shown on optional roll stand. Ventilator may be mounted either way round on stand.

More information

Flow meter. bellow vaporizer. APL valve. Scavenging system

Flow meter. bellow vaporizer. APL valve. Scavenging system Introductory Lecture Series: The Anesthesia Machine PORNSIRI WANNADILOK Objectives Anesthesia Machine Ventilators Scavenging Systems System Checkout 1 Flow meter ventilator bellow vaporizer Corrugated

More information

Great products available through ROI!

Great products available through ROI! Great products available through ROI! AGREEMENT NUMBER Through May 31, 2019 DISP. FIBER OPTIC LARYNGOSCOPES Blades and handles completely disposable Blades constructed of surgical stainless steel, and

More information

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV VENTIlogic LS VENTIlogic plus 100 % Mobility and Reliability in IV and NIV VENTIlogic VENTIlog LS Your Requirements for Reliability and Mobility are Our Benchmark. VENTIlogic LS and VENTIlogic plus are

More information

Breathing Systems. Professor Khalid Bashir

Breathing Systems. Professor Khalid Bashir Breathing Systems Professor Khalid Bashir Introduction The devices that connect and deliver anaesthetic gases from anaesthetic machine to patient Spontaneous respiration / IPPV Ports for gas sampling,

More information

Complex Care Hub Manual: Pressure Ventilation on the LTV 1200

Complex Care Hub Manual: Pressure Ventilation on the LTV 1200 Complex Care Hub Manual: Pressure Ventilation on the LTV 1200 Table of Contents 1 Mechanical Ventilation... 3 2 Important information for support worker... 3 3 Commonly used terms... 3 3.1 Inspiration...

More information

1 of 9 10/20/2010 4:45 PM

1 of 9 10/20/2010 4:45 PM 1 of 9 10/20/2010 4:45 PM This is the ventilator you've been looking for - compact, lightweight, unsurpassed reliability, and self contained. Its comprehensive, versatile features meet the demands of almost

More information

Airways and Resuscitators. CRC 330 Cardiorespiratory Care University of South Alabama

Airways and Resuscitators. CRC 330 Cardiorespiratory Care University of South Alabama Airways and Resuscitators CRC 330 Cardiorespiratory Care University of South Alabama Causes of Upper Airway Obstruction CNS depressionanesthesia, drug overdose Cardiac arrest Loss of consciousness Foreign

More information

Confidence. in your patient s comfort Philips Respironics patient interfaces and circuits for noninvasive ventilation

Confidence. in your patient s comfort Philips Respironics patient interfaces and circuits for noninvasive ventilation Hospital respiratory care Confidence in your patient s comfort Philips Respironics patient interfaces and circuits for noninvasive ventilation Delivering exceptional NIV Philips Respironics masks are designed

More information

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE Critical Care SERVO-s 3 SERVO-s SIMPLY MAKES SENSE MAQUET THE GOLD STANDARD Leading the way: MAQUET is a premier international provider of medical products

More information

Oxylog VE300 Emergency & Transport Ventilation

Oxylog VE300 Emergency & Transport Ventilation Oxylog VE300 Emergency & Transport Ventilation The straightforward and user-friendly Dräger Oxylog VE300 is built to face your challenges in preclinical emergency services With reliable ventilation technology,

More information

Hallowell EMC Anesthesia WorkStation Operating Manual

Hallowell EMC Anesthesia WorkStation Operating Manual Hallowell EMC Anesthesia WorkStation Operating Manual PN 000a2770 Anesthesia WorkStation A compact (9" W x 9" D x 15" H), convenient system for use on animals under 7 kg (15 lb.) Hallowell Engineering

More information

Update to RS-232 commands. Changing patient from NIV to INVASIVE Vent Type. SNDF command

Update to RS-232 commands. Changing patient from NIV to INVASIVE Vent Type. SNDF command Changing patient from NIV to INVASIVE Vent Type Table 9 shows automatic settings changes that occur when changing the same patient from NIV to INVASIVE Vent Type. Table 9: Automatic settings changes NIV

More information

NEONATAL/INFANT VENTILATOR

NEONATAL/INFANT VENTILATOR n a!! i le ion b a a i l ve r s v w a lone o N d-a n sta FEATURES: MDES F VENTILATIN PRESSURE LIMITED/ CNTINUUS FLW FLW TRIGGERED VLUME VENTILATIN NENATAL/INFANT VENTILATR The Crossvent 2i+ ventilator

More information

Inspire rpap REVOLUTION FROM THE FIRST BREATH

Inspire rpap REVOLUTION FROM THE FIRST BREATH Inspire rpap TM REVOLUTION FROM THE FIRST BREATH The Inspire rpap The Inspire rpap is a revolutionary, non-invasive system for the initial stabilisation and resuscitation of infants. TM Its innovative,

More information

Provide Comfort to your Patients is our commitment PRODUCT CATALOGUE HOSPTIAL SUPPLIES. Copyright ReadMed Company Ltd

Provide Comfort to your Patients is our commitment PRODUCT CATALOGUE HOSPTIAL SUPPLIES. Copyright ReadMed Company Ltd Provide Comfort to your Patients is our commitment PRODUCT CATALOGUE HOSPTIAL SUPPLIES 1 Copyright ReadMed Company Ltd Introduction ReadMed Company Ltd. Specializes in manufacturing and exporting selected

More information

TUBINGS / CONNECTION PIECES

TUBINGS / CONNECTION PIECES SILICONE TUBINGS, smooth autoclavable, Color: transparent O.D. I.D. I.D. x C O.D. REF Box (mm) (mm) 0.5 x 0.4 1.3 68-005-04 25 m 1.0 x 0.5 2.0 68-010-05 25 m 1.0 x 1.0 3.0 68-010-10 25 m 1,5 x 0.75 3.0

More information

A9600 Anesthesia Workstation. Your healthcare, we care.

A9600 Anesthesia Workstation. Your healthcare, we care. A9600 Anesthesia Workstation Your healthcare, we care. A9600 is an advanced yet easy to use anesthesia workstation that provides accurate, pneumatically driven and electronically controlled ventilation.

More information

SLE5000 Neonatal Ventilator with High Frequency Oscillation

SLE5000 Neonatal Ventilator with High Frequency Oscillation SLE5000 Neonatal Ventilator with High Frequency Oscillation The SLE5000 is superb: the best High Frequency Ventilator I ve used When the smallest thing matters SLE5000 - The Total Solution for Infant Ventilation

More information

Infant Ventilators. Infant Ventilator with Touch-Screen Operation SLE4000

Infant Ventilators. Infant Ventilator with Touch-Screen Operation SLE4000 Infant Ventilators Infant Ventilator with Touch-Screen Operation SLE4000 SLE4000: Designed for Infants Sophisticated and Powerful To keep up with the latest in ventilation the SLE4000 has continually reinvented

More information

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare patient education program 4156 South 52 nd Street, Omaha, NE 68117 800-747-7334 402-734-6741 ChildrensOmaha.org/HomeHealthcare We know children CHILDREN S HOME HEALTHCARE Trilogy Ventilator Instructions

More information

Unit 15 Manual Resuscitators

Unit 15 Manual Resuscitators 15-1 Unit 15 Manual Resuscitators GOAL On completion of this unit, the student should comprehend the proper operation of self-inflating resuscitation bags, flow-inflating resuscitation bags and gas-powered

More information

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV VENTIlogic LS VENTIlogic plus 100 % Mobility and Reliability in IV and NIV VENTIlogic LS VENTIlogic plus Your requirements for reliability and mobility are our benchmark. VENTIlogic LS and VENTIlogic plus

More information

Welcome to Maxstar Medical

Welcome to Maxstar Medical Maxstar Medical Welcome to Maxstar Medical Maxstar Group of Companies is a group of three professional manufacturing companies with a focus on manufacturing and exporting of wide range of medical hospital

More information

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Narkomed MRI-2 A perfect fit for the MRI environment Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Because you care The complete anesthesia solution for the MRI environment A

More information

1st Response Disposable Manual Resuscitators. Safe Convenient Trusted

1st Response Disposable Manual Resuscitators. Safe Convenient Trusted 1st Response Disposable Manual Resuscitators Safe Convenient Trusted HELPING DELIVER PATIENT SAFETY IN-LINE WITH YOUR NEEDS Safe In-line color coded manometer guides clinician to accurate airway pressure

More information

Accessory Catalogues. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Accessory Catalogues. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care ccessory Catalogues Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Breathing Systems and ccessories OR/nesthesia breathing circuits/sets Breathing Systems. Breathing circuits/sets

More information

pneuton Transport Ventilator

pneuton Transport Ventilator The pneuton Ventilator is under US patent protection. (Patent # 6,591,835) pneuton is a Registered Trademark of the Airon Corporation Copyright 2012 by Airon Corporation pneuton Transport Ventilator mini

More information

Confidence. in your patient s comfort Philips Respironics patient interfaces and circuits for noninvasive ventilation

Confidence. in your patient s comfort Philips Respironics patient interfaces and circuits for noninvasive ventilation Hospital respiratory care Confidence in your patient s comfort Philips Respironics patient interfaces and circuits for noninvasive ventilation Delivering exceptional NIV Philips Respironics masks are designed

More information

FLOWMETER UNITS FLOWMETER DEVICES, BY-PASS SYSTEMS

FLOWMETER UNITS FLOWMETER DEVICES, BY-PASS SYSTEMS FLOWMETER UNITS The range of anesthesia flowmeter units series FM, SF and RM, available in different configurations, makes it possible to offer many options to meet various requirements in the operating

More information

WILAmed INTENSA. Intensive Care Ventilator System

WILAmed INTENSA. Intensive Care Ventilator System EN WILAmed INTENSA Intensive Care Ventilator System 0197 WILAmed INTENSA Ventilator System The WILAmed INTENSA is a full invasive and non-invasive life-support ventilator, solely designed for the ventilation

More information

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES DATA ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES CRITICAL CARE HIGHLIGHTS! For all patient categories, from neonate and pediatric to adult! A platform for the future choose the level of system

More information

Ventilator Training Module

Ventilator Training Module Ventilator Training Module LTV (Lap Top Ventilator) Teaching Script LTV User guides: http://www.carefusion.com/documents/guides/user-guides/rc_ltv-1000_ug_en.pdf http://www.carefusion.com/documents/guides/user-guides/rc_ltv-1100_ug_en.pdf

More information

Oxylog 3000 plus Emergency & Transport Ventilation

Oxylog 3000 plus Emergency & Transport Ventilation Oxylog 3000 plus Emergency & Transport Ventilation Offering high ventilation performance with features such as AutoFlow, integrated capnography and non-invasive Ventilation, the compact and robust Oxylog

More information

Anesthesia Workstation

Anesthesia Workstation Your healthcare, we care. A9800 Anesthesia Workstation Technical Parameters A9800 Ventilation Modes Alarms Volume Control Pressure Control SIMV with Pressure Support (SIMV + PS) - with Volume or Pressure-type

More information

We Warm Animals. User Manual For. Darvall Heated Smooth-Wall Circuits. Darvall Heated ZDS Qubes

We Warm Animals. User Manual For. Darvall Heated Smooth-Wall Circuits. Darvall Heated ZDS Qubes We Warm Animals User Manual For Warm Inspired Air Control Unit to use with Darvall Heated Smooth-Wall Circuits or Darvall Heated ZDS Qubes For Veterinary Use Only Warm Inspired Air Control Unit Use for

More information

Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

Automatic Transport Ventilators. ICU Quality Ventilation on the Street. Automatic Transport Ventilators ICU Quality Ventilation on the Street. Kevin Bowden, March 20 th 2014 Ventilator Definition A ventilator is an automatic mechanical device designed to provide all or part

More information

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products Saturn Evo SATURN EVO COLOR A N A E S T H E S I A S Y S T E M i n t e l l i g e n t s i m p l i c i t y Manufacturer of high quality anaesthesia products SATURN EVO COLOR PATIENT SAFETY AND USER PATIENT

More information

Air Flow & Gas Analysis Accessories

Air Flow & Gas Analysis Accessories AFT Series Air Flow & Gas Analysis Accessories AFT1 AFT2 AFT3 AFT4 AFT6 AFT7 AFT8 AFT 9 AFT10 Disposable Bacterial Filter 22mm ID/OD; designed to remove airborne bacteria; for use between the TSD117 and

More information

The Anesthesia Machine (con t) The primary cause of machine malfunction is failure to check Never start without the American Express items What is the

The Anesthesia Machine (con t) The primary cause of machine malfunction is failure to check Never start without the American Express items What is the Anesthesia Machine The Anesthesia Machine You are the master of the machine You are responsible for checking the machine prior to each case 1 The Anesthesia Machine (con t) The primary cause of machine

More information

2015 Hamilton Medical AG. All rights reserved. Printed in Switzerland.

2015 Hamilton Medical AG. All rights reserved. Printed in Switzerland. HAMILTON-T1 Quick Guide This Quick Guide is intended as a useful reference for ventilation of adult and pediatric patients. It does not replace the clinical judgment of a physician or the content of the

More information

State-of-the-art anesthesia technology

State-of-the-art anesthesia technology State-of-the-art anesthesia technology anesthesia system Get closer to the MRI scanner Superb certified performance in close proximity to strong magnetic fields. Our innovative machine provides benefits

More information

MEDICAL EQUIPMENT IV MECHANICAL VENTILATORS. Prof. Yasser Mostafa Kadah

MEDICAL EQUIPMENT IV MECHANICAL VENTILATORS. Prof. Yasser Mostafa Kadah MEDICAL EQUIPMENT IV - 2013 MECHANICAL VENTILATORS Prof. Yasser Mostafa Kadah Mechanical Ventilator A ventilator is a machine, a system of related elements designed to alter, transmit, and direct energy

More information

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features)

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features) The Crossvent 2i+ 1. How is this ventilator classified 2. Ventilator Concept (brief theory of operation and features) -Your Two Choices with this Ventilator 3. An overview of the device (an in-service)

More information

Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator

Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator 1 Applications of the MCV100(B) The MCV100 and MCV100-B Mass Casualty Ventilators are electronically controlled portable ventilators,

More information

Department of Paediatrics

Department of Paediatrics KASTURBA HEALTH SOCIETY'S MAHATMA GANDHI INSTITUTE OF MEDICAL SCIENCES, P.O. SEVAGRAM, WARDHA (DISTT.) MAHARASHTRA STATE - 442 102 Specifications for Equipment Department of Paediatrics 1. A) Ventilator

More information

Instructions for Use. OptiLife Nasal Lab Mask

Instructions for Use. OptiLife Nasal Lab Mask Instructions for Use OptiLife Nasal Lab Mask Intended Use The OptiLife Nasal Mask is intended to provide an interface for application of CPAP or bi-level therapy to patients. The mask is for multi-patient

More information

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Fabius Tiro TM Designed for your environment Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Traditional hospital ORs have their needs... With more surgical procedures being performed

More information

Anaesthetic and respiratory equipment Breathing sets and connectors

Anaesthetic and respiratory equipment Breathing sets and connectors Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 5367 Fifth edition 2014-10-15 Anaesthetic and respiratory equipment Breathing sets and connectors Matériel d anesthésie et de réanimation respiratoire

More information

V8800 Ventilator System. Your healthcare, we care.

V8800 Ventilator System. Your healthcare, we care. V8800 Ventilator System Your healthcare, we care. V8800 Ventilator System V8800 is a critical care ventilator for infants, children and adults. It has comprehensive functionality, a user-friendly design,

More information

Corporate Overview and Product Summary

Corporate Overview and Product Summary 2008 Corporate Overview and Product Summary Vapotherm Summary: Market leader and originator of High Flow Therapy Founded in 1999 Headquartered in Stevensville, MD Clinical and education leadership in High

More information

Your patients, our primary focus. Siesta i Whispa anesthesia machine

Your patients, our primary focus. Siesta i Whispa anesthesia machine Your patients, our primary focus Siesta i Whispa anesthesia machine Functional, and flexible At Dameca we are not just committed to meeting the healthcare needs of today. We also think about tomorrow.

More information

SySTEm Flow chart ANESTHESIA patient connection

SySTEm Flow chart ANESTHESIA patient connection System Flow Chart ANESTHESIA patient connection PATIENT CONNECTION ANESTHESIA STARTER KIT CONSUMABLES One selected kit may be ordered with every FLOW-i 10 mm Starter kit Anesthesia, adult, 66 96 810-1

More information

EasyFit Lite Nasal Mask, Silicone. Nasal Mask. EasyFit Lite Nasal Mask. Device Description and Instructions for Use. Caution:

EasyFit Lite Nasal Mask, Silicone. Nasal Mask. EasyFit Lite Nasal Mask. Device Description and Instructions for Use. Caution: EasyFit Lite Nasal Mask EasyFit Lite Nasal Mask, Silicone Nasal Mask Device Description and Instructions for Use Caution: Federal Law (U.S.A.) restricts this device to sale by or on the order of a physician.

More information

Puritan Bennett 840 Universal Ventilator

Puritan Bennett 840 Universal Ventilator Puritan Bennett 840 Universal Ventilator ne Ventilator for Every Area of Care Healthcare providers and patients throughout the world depend on Covidien for state-of-the-art ventilation therapy. Whether

More information

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting This is a quick reference for setting up, using, and troubleshooting the Hallowell EMC 2000 and 2002 Small Animal Ventilator.

More information

Mirage Vista Nasal Mask

Mirage Vista Nasal Mask English 60 50 40 30 20 10 0 4 6 10 12 14 16 1 20 ENGLISH Mirage Vista Nasal Mask Rx Only The Mirage Vista Nasal Mask is an accessory to a non-continuous ventilator (respirator) intended for multipatient

More information

Intensa GO Alternate Care Ventilator

Intensa GO Alternate Care Ventilator EN Intensa GO Alternate Care Ventilator 0197 Intensa GO Versatility and simplicity The all new WILAmed Ventilator INTENSA Go offers great versatility and simplicity. It is designed to ventilate (invasive

More information

The anaesthesia workstation focused on you

The anaesthesia workstation focused on you by The anaesthesia workstation focused on you The anaesthesia Accuracy and performance Equipped with the most advanced ventilation modes. Electronic rotameters with precise mass-flow sensors, allowing

More information

AirLife. International respiratory product catalogue

AirLife. International respiratory product catalogue AirLife International respiratory product catalogue Table of contents Arterial blood gas sampling 6-7... Reduced heparin samplers 8-11... Kits 10-11... Aspirators Bronchial hygiene 14... Incentive spirometers

More information

GE Healthcare. Aestiva/5. More than superior ventilation

GE Healthcare. Aestiva/5. More than superior ventilation GE Healthcare Aestiva/5 More than superior ventilation A balance of superior ventilation and award-winning design SmartVent the shape of superior ventilation At the heart of the Datex-Ohmeda Aestiva /5

More information