Technical Manual. Barge System OPTILEVEL

Size: px
Start display at page:

Download "Technical Manual. Barge System OPTILEVEL"

Transcription

1 Barge System OPTILEVEL Technical Manual SAS au Capital de R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton Bourges - France

2 Barge System Technical Manual OPTILEVEL 1 st Edition Released February 2013

3 INTRODUCTION This manual is issued specifically for the OPTILEVEL system. It contains instructions detailed for functioning and operation of this system. To use it in an optimal way, we advise you TO READ CAREFULLY THESE INSTRUCTIONS and to respect them throughout the life of the equipment. Keep this manual to hand so that you can refer to it at any time. Ensure that it is complete and kept close to the equipment. The OPTILEVEL HLS 6010 probe, OPTILEVEL Supply, T901-P transmitter and LOG3840 indicator are integrated in the system for processing the barges/inland vessels liquid cargo. This system is intended for professional use, it must be used by operators who are qualified and well-versed in the operating rules and safety instructions set out in this manual. We also draw your attention to the fact that the connection of equipments or the use of products other than those recommended by Honeywell Marine may present risks for which we will not be liable. This manual must not be reproduced in any form whatsoever without the prior written approval of Honeywell Marine who cannot be held responsible for any use of the information contained in this manual. As we want you to take advantage of the most of the latest technology and new equipment, as well as to benefit from our experience, our equipments may undergo technical or design changes. As a result, some of the features and information in this manual may change without prior notice and without any obligation to up-date it. Pictures of this document are not contractual. Should you encounter any problems or have any questions about your EMx40 system, please do not hesitate to contact your nearest Honeywell Marine customer service. Other documents The description and operation of the racks TA3840C/R and TA3840S for measuring data collection are described in the MT5008E technical manual. SAFETY PRECAUTIONS: Current regulations and legislation applicable to hazardous areas must imperatively be known and followed by personnel responsible for commissioning and operating intrinsically safe equipment. Take care to switch the power off before proceeding to any disconnection or removal of the transmitters.

4 WARNING: Our equipments are designed and manufactured in accordance with local safety regulations, and in particular European directives relative to reconciling member states' legislation: 89/336/EEC and 2004/108/EC "Electromagnetic compatibility", ATEX 94/9/EC "Equipment and protective systems intended for use in potentially explosive atmospheres", 96/98/EC "Marine equipment". The OPTILEVEL HLS 6010 / OPTILEVEL Supply and associated transmitters are certified for use in hazardous area according to the intrinsic safety protection type. Examination certificates are supplied in appendix. They are intended for professional use and must be installed, used and maintained by competent staffs that are qualified in this type of equipment. In particular we wish to draw your attention to the fact that we cannot be held responsible if: Any technical alterations are made to our appliances without our written authorisation, Our equipments are damaged by being operated in conditions other than the intended usage of their technical classification (power supply, temperature, environment, etc.). The safety instructions given in this manual are merely given for guidance purposes to protect you and all those using and working on our equipments. Honeywell Marine cannot foresee all dangerous situations that might arise. This is why the owner and/or the operator is responsible for the operating safety of the system. Regulations of the ship classification society may impose procedures (health and safety, fire prevention, handling of hazardous substances, etc.) which are stricter than those given in this manual. In this case, the regulations must be followed.

5 TABLE OF CONTENTS 1. GENERAL DESCRIPTION OPTILEVEL HLS 6010 probe OPTILEVEL Supply INSTALLATION Potential equalization Ex-technical information HLS 6010 probe Ex-technical information OPTILEVEL Supply Laying the cables Installation of the probe Connection of OPTILEVEL Supply START-UP Preparations Start Terminal program (Configuration) Assign address / product (tank) COMMUNICATION Communication settings Commands for installation and service Standard commands Structure of $-Commands CERTIFICATES / APPROVALS Probe HLS Optilevel Supply... 25

6 1. GENERAL DESCRIPTION TA3840R Monitoring computer RS232 / RS485 / RS422 Loading computer +24 Vdc power supply 3 dry contact outputs: - data alarm, - system fault, - power supply failure. Monitoring computer when fitted with CPU board, as option 24 Vdc + RS232 / RS485 / RS422 TA3840C Up to ma inputs or On / Off inputs or On / Off outputs RS232 / RS485 Special applications Configuration software 230 / 115 Vac 50 / 60 Hz Power supply OPTILEVEL Supply LOG3840 (optional) or OPTILEVEL HLS 6010 gauge T901-PxxC Up to 3 temperature sensors and 1 inert gas pressure sensor Pressure sensor OPTILEVEL Technical Manual 6

7 System description The OPTILEVEL HLS 6010 probe, OPTILEVEL Supply, T901-P temperature/pressure transmitters and LOG3840 deck digital indicator are parts of the OPTILEVEL system, dedicated to monitor the Barges/Inland vessels liquid cargo parameters such as level, temperature and pressure, as well as all associated measurements. They are installed in hazardous area. The OPTILEVEL HLS 6010 probe measure the liquid level inside the tank and the temperature and transmit the information to the TA3840C communication unit by means of the OPTILEVEL Supply located in Safe area. The T901-P temperature / pressure transmitters measure the liquid cargo temperature (if more than 1 temperature is requested) and the inert gas pressure. Each T901-P transmitter is directly connected to TA3840C analogue input board. (Already Marine certified). The LOG3840 deck digital indicator displays locally the level, temperatures, pressure measured by transmitters. It is powered by the TA3840S safety unit and communicates on a RS485 bus. (Already Marine certified). General synopsis The general synopsis of the system is shown on the previous page. TA3840C, TA3840S, TA3840R T901-P and LOG3840 are part of EMx40 system (see MI5016, MT5016 & MM5016). 2. OPTILEVEL HLS 6010 probe The probe consists of the head housing with the electronics, a screw thread to fasten it to the tank and the measuring tube. The measuring tube varies in length depending on the tank height. Important ordering information: To produce a probe we always need the following information: LL = Tank height LG = Probe length Standard lengths (in mm): Tank height. (LL) Probe length (LG) Segment length Special lengths (minimum/maximum lengths in mm): Tank height. (LL) Probe length (LG) Segment length OPTILEVEL Technical Manual 7

8 3. OPTILEVEL Supply The OPTILEVEL Supply provides the power to the connected probes. Depending on the number of probes to be connected there are different versions available. Up to 4 Supplies can be operated parallely, so that a maximum number of 32 probes can be connected. Superior systems can be connected to the RS232 standard interface. At the same time the Supply takes over the galvanic separation of each individual probe and offers thereby a safe explosion prevention. 4. INSTALLATION 4.1 Potential equalization As the intrinsically safe circuit is operationally earthed, a common potential equalisation must be provided within the intrinsically safe circuit (within and outside the explosion hazardous area). The probe must be connected to the same potential equalisation (earthing) as the tank. See also paragraph: Connect the 4 mm² cable for potential equalisation to the ground clamp on the housing and link it to the tank lid Galvanic separation by OPTILEVEL Supply: The Level Sensor (HLS 6010) is galvanically separated by the ex-barrier (OPTILEVEL Supply). The shield of the connection cable must be connected to the probe head (housing) and to the E terminal clamp on the Supply. Installation regulations: The earthing of the tank, its cables, etc., resides with the installation engineer or the planning office and is normally examined and adjusted on-site. The probe s earthing must also be connected to the tank. OPTILEVEL Technical Manual 8

9 4.2 Ex-technical information HLS 6010 probe Ex-Classification SEV 09 ATEX 0109 IECEx SEV Rating data Supply and signal circuit II 1/2 G Ex ia IIB T4 Ga/Gb Ignition protection type intrinsic safety Ex ia IIB Only for connection to an acknowledged intrinsically safe circuit. Maximum values: Ui 15,9 V Ii 250 ma Pi 1,2 W The supply and signal circuits are operationally earthed. Ci = 210 nf Li is neglectably small Remarks The tank level probe type HLS 6010 belongs to equipment of group II, category 1/2 G according to regulation 94/9/EG (ATEX 95) Appendix I, and can - according to RL 99/92/EG (ATEX 137) - be used in danger areas 0/1 or 0/2 as well as in gas groups IIA and IIB which are potentially explosive by flammable substances within temperature classes T1 to T4. The requirements according to EN must be adhered to during use and installation. The approved environmental temperature range is 20 C to +60 C. Special conditions X None Type label OPTILEVEL Technical Manual 9

10 4.3 Ex-technical information OPTILEVEL Supply Ex - Classification II (1) G [Ex ia Ga] IIB EPL (Ga) TÜV 98 ATEX 1382 Rating data The approved environmental temperature range is 20 C to +60 C for the OPTILEVEL Supply and 20 C to +70 C for the OPTILEVEL Supply TA. Supply circuit (Terminal clamps PH, N) Output and signal circuit(s) (Terminal clamps +, -, Shd) Maximum values per circuit RS232 interface: (Terminal clamps RXD, TXD, GND) Interface circuit Master-Slave (Terminal clamps In, Out) U = 230V AC, +-10%, 50Hz, Umax 253V Ignition protection type intrinsic safety Ex ia IIB Uo = 14.3 V Io = 221 ma P = 1.2 W R = 190 Ω Characteristic curve trapeze-shaped Active inner capacitance: 145 nf The active inner inductances are neglectable small. Maximum permissible outer inductance: 1 mh Maximum permissible outer capacitance: 562 nf +-15 V 5V The output and signal circuits are galvanically separated from the non-intrinsically safe circuits up to a crest voltage of 375V. Special conditions X None Type label OPTILEVEL Technical Manual 10

11 4.4 Laying the cables General Use screened blue polyurethane cable (3x0, 75 mm²) with a diameter of 5 9 mm, which is resistant to oil and petrol products and has a maximum length of 250 meters. THESE CABLES MUST BE LAID SEPARATELY, i.e. they must be isolated from power cables. The valid high voltage current regulations must be observed! CABLE CAPACITY: Please note that the cable capacity together with the probe s inner capacity Ci must not exceed the maximum outer capacity of the Supply (562nF). NEVER LEAVE A CABLE END IN THE LIQUID! Due to the capillary effect the liquid might penetrate the cable and cause a short circuit. 4.5 Installation of the probe Preconditions Procedure All cables are laid A G1½ -inch or NPT female thread has been installed on the dome cover 1. Wind Teflon tape or hemp yarn around the nipple of the compression fitting 2 Untighten the compression fitting gland of the probe (2 x 60mm jaw spanners) are required 3 Slide the compression fitting down to the welding points and tighten it slightly 4 Place the probe in the tank and tighten the nipple 5 Untighten the PVC gland 6 Place the probe on the bottom of the tank 7 Put the sensor adjusting tool on the dome lid and move the slide upwards to the lower edge of the sensor head. Block the slide with the fixing screw 8 Lift the probe slightly and remove the sensor adjusting tool 9 Move the slide of the sensor adjusting tool 10 mm upwards and block it again by means of the fixing screw OPTILEVEL Technical Manual 11

12 10 Place the sensor adjusting tool back on the dome lid in the same position as before 11 Lower the probe until the lower edge of the probe head rests on the slide again 12 Tighten the compression fitting of the HLS (Working thoroughly will ensure that the probe end will be placed exactly 10 mm above the bottom of the tank) To guarantee the density of the installation the compression fitting must be tightened to 70Nm min. Taking a spanner with 500mm length equals a weight of 15 kg! 13 Write down the tank number and medium on the test report (will be needed for commissioning). Mention on the test report if the probe cannot be mounted in parallel to the tank axis OPTILEVEL Technical Manual 12

13 4.5.1 Dimensions LPG gauge (in mm) Electrical connection Laying the cables 1. Connect the 4 mm² cable for potential equalization to the ground clamp on the housing and link it to the tank lid 2. Remove the housing lid of the probe head 3. Untighten the PG gland 4. Skin the probe cable and provide it with cable end sleeves 5. Guide the probe cable through the PG gland 6. Tighten the PG gland until the rubber seal forms a small bulge 7. This cable gland meets the tightness requirements according to IP 66/67, i.e. among others that if the probe is immersed permanently into water, no water may penetrate the electronics. Therefore, this work must be carried out with utmost care! CAUTION! The screening of the probe cable must be provided with an insulating hose. Wire or cable residuals must not remain in the probe head! OPTILEVEL Technical Manual 13

14 4.5.4 Connection of power supply and signals 1 Connect the grounding braid 1 in the housing lid to a free E - terminal clamp on the electronics. 1 2 Connect the probe cable to the terminal clamps on the head electronics The screening of the probe cable is connected directly to the second E - terminal clamp or the additional screw in the head housing! Probe head with grounding braid Electronics with terminal clamps Close probe head housing lid CAUTION! The probe head housing lid must be tightened cross-wisely so that thightness according to ip66/67 is guaranteed. 1. Start by tightening screws 1 and 3 slightly. 2. Then, tighten screws 2 and 4 slightly. 3. Check if the housing lid fits the bottom parallel. 4. Tighten screws 1 and 3 completely. 5. Tighten screws 2 and 4 completely. 6. Note down tank, product and mechanics number (important for probe initialisation). OPTILEVEL Technical Manual 14

15 4.6 Connection of OPTILEVEL Supply Variants Variant 1 (Stand alone) This variant is used if a Supply is used without OPTILEVEL Controller. Variant 2 (Slave) Master and Slave are mounted next to each other (mounting version 1). If there is not enough space Master and Slave can also be mounted above each other (mounting version 2). The OPTILEVEL supply must be mounted outside the ex area! Mounting 1. Open the upper lid of the Supply The picture at the bottom shows a Supply 8. The Supplies 1, 4 and 5 are the same size, but there are less channels assembled. 2. Fasten OPTILEVEL Supply to the wall with 4 screws. ATTENTION! ELECTROSTATICALLY CHARGEABLE COMPONENTS! Reduce electrostatic charge before touching the board. There might be tension on the solder points of the transformers that have not been OPTILEVEL Technical Manual 15

16 Key: A Blind cover on connection hole F Terminal clamp RS232 B Fixing holes G Terminal clamp Master / Slave C Fixing holes for lid H Blind cover on connection hole for further Supplies D Terminal clamp for connection of power supply I Cable gland E Control light power supply K Terminal clamps for probes 1 Separate power supply for each probe 2 Opto coupler for galvanic separation Up to 8 probes can be connected to the Supply in any order. However, we recommend you connect the probe of tank no. 1 to the first connector, the probe of tank no. 2 to the second connector, a.s.o. This will help you identify the probes in case of any error. OPTILEVEL Technical Manual 16

17 4.6.3 Connection plan OPTILEVEL Technical Manual 17

18 5. START-UP Terminal program: You may configure the probe with a terminal program using the corresponding commands. This procedure is described on the following pages 5.1 Preparations General: Requirements: Connect your PC to the Supply via serial interface PC with a Terminal program (e.g. Hyperterminal, OC Console) Connection cable for the serial interface to OPTILEVEL Supply: RS 232 terminal Supply Laptop (9-pole D-Sub) RES Reserve GND GND (Pin 5) RxD TxD (Pin 3) TxD RxD (Pin 2) Make sure that you have the probe mechanics number, the medium as well as the tank number at hand. 5.2 Start Terminal program (Configuration) 1. Start the Terminal program 2. Baud rate: 9600 (standard with delivery) 3. Parity: N (none) 4. Data bits: 8 5. Stop bits: 1 6. Port: depends on the port that is used 7. no handshake 8. local echo on OPTILEVEL Technical Manual 18

19 5.3 Assign address / product (tank) In order to allow the interpreting device to communicate with the single probes, a unique address must be allocated to each probe Commands Entries via Terminal program We recommend you use the tank number as the probe s address, so that each probe can be assigned clearly to a tank. Should you wish to assign different probe and tank numbers, you must create a thorough documentation! Communication with the probes is effected by certain commands. The assignment of probe address and product is carried out by entering the command: *A <probe number> 1. All other commands are described separately in chapter 5. Monitor: Enter the probe s ID number (can be found on type label). In this example it is: A probe address will be requested. Enter a number (two digits). Normally, the tank number is used. The probe will confirm your entry. The probe address is 01. Specify the product which will be in the tank. This entry helps the probe to reach a relatively high accuracy immediately after switch-on and before adjusting itself to the new medium. Remarks: - Enter 4 (Diesel) if the medium is unknown - Enter 8 for products with an Er 2 - value > 3, such as water, AdBlue, E85 The probe will confirm you entry. Done! 1 = <CR> or <Enter> or <Return> 2 Er stands for εr = dielectric constant OPTILEVEL Technical Manual 19

20 6. COMMUNICATION 6.1 Communication settings General Check if the following settings have been made: Baud rate: depending on probe settings (see footnote) Parity: N (none) Data bits: 8 Stop bits: 1 COM Port: depends on the port used Local echo: on 6.2 Commands for installation and service Command Answer Description Syntax Syntax Description Set address and medium *A< probe ID ><CR> Dialogue Set address and medium in dialogue. Change baud rate1 *B<adr>bbbb2 ><CR> <Value><CR> Confirmation H-protocol (description see page 37) *J<adr><Value<CR> <Values> Fill level data transferred to POS system. Set medium *M<adr> Selection list Set medium in dialogue with probe Set Offset (absolute) *O<adr><Value><CR> #0<Value><CR > Internal Offset <Value>=Offset [mm] Replace *R<ID> Electronics><CR> Dialogue Adjustment of electronics, offset and reprogramming of wet and dry values. Dry value adjustment *U<ID> Electronics><CR> Dialogue HF Upgrade Offset adjustment *Y<adr<Value><CR> #Value Enter the value of a manual dipstick reading. The probe will then calculate a new offset value and adjust the old value. Request service data $S<adr><CR> Text Service data Request service data in $I<adr><CR> Text Service data in English English Request extended service data $E<adr><CR> Text Service data extended Special command (usually used if you are not sure about a probe s address) $S99<CD> Text Each probe connected will reply to this command. Therefore, only one probe must be connected when carrying out this command. 1 Please note: after having changed the baud rate you must also change the baud rate of the terminal program. 2 bbbb: baud rate (300 baud (= default), 1200, 2400, 4800, 9600 or baud) OPTILEVEL Technical Manual 20

21 6.3 Standard commands Command Answer Description Syntax Syntax Description Retrieve all level values $A<adr><CR> <Values><CR> Command for Controller3 Retrieve all volume values $B<adr><CR> <Values><CR> Volume command with strapping table on probe only Retrieve all ullage values $C<adr><CR> <Values><CR> Ullage command with strapping table on probe only Retrieve water level $G<adr><CR> #=<Value><CR> Water level in mm Retrieve temperature $T<adr><CR> #[±]<Value><CR > Temperature in C/10 Retrieve fill level $V<adr><CR> #0<Value><CR> Fill level in mm 6.4 Structure of $-Commands $A-Command Syntax (ASCIIcharacters) Value Value Value Value Value Value > <CR> $B-Command Syntax (ASCIIcharacters) #< Value Value Value Value Value Value Value > <CR> 3 Not used Range of values (ASCII-characters) FF Range of values (ASCII-characters) FF Description Fill level in mm/10 Water level in mm Temperature in C/10 Probe offset in mm Software version Probe error Checksum Description Volume in litres Water level in mm Temperature in C/10 Probe offset in mm Software version Probe error Checksum OPTILEVEL Technical Manual 21

22 6.4.3 $C-Command Syntax (ASCIIcharacters) #< Value Value Value Value Value Value Value > <CR> *¹ Sensor errors 1 Wrong DIP Switch settings (only for old 5-segment and 9+1 probes) 2 No connection to EEPROM 3 No electronics adjustment done (usually carried out by Hectronic) 4 No dry and wet value adjustment done (usually carried out by Hectronic) 5 A field adjustment is being carried out (only with old HF Industry Software) 6 Temperature sensor error The following error message might be displayed in case of an error: *² Checksum calculation Range of values (ASCII-characters) FF Description Ullage in litres Water level in mm Temperature in C/10 Probe offset in mm Software version Probe error*¹ Checksum*² The checksum is the XOR link of all characters, checksum value and <CR> excluded. The checksum is displayed in HEX. OPTILEVEL Technical Manual 22

23 7. CERTIFICATES / APPROVALS 7.1 Probe HLS 6010 OPTILEVEL Technical Manual 23

24 OPTILEVEL Technical Manual 24

25 7.2 Optilevel Supply OPTILEVEL Technical Manual 25

26 OPTILEVEL Technical Manual 26

27

28 Honeywell Marine SAS 9, Rue Isaac Newton Bourges France Tel + 33 (0) Fax + 33 (0) contact.marine@honeywell.com MT5025E-rev03-ENG February Honeywell International Inc.

Magnetic level switch type MR783 Instruction Manual

Magnetic level switch type MR783 Instruction Manual Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2

More information

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature

More information

Technical Manual. Liquid Level Transmitter CT801-LB/S

Technical Manual. Liquid Level Transmitter CT801-LB/S CT801-LB/S Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual CT801-LB/S 1 st Edition Released

More information

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] 12th Edition 1 1. Introduction Thank you for purchasing the DPharp electronic pressure transmitter. This manual

More information

Maintenance Manual. Liquid Level Transmitter CT801-SI, CT801-TA

Maintenance Manual. Liquid Level Transmitter CT801-SI, CT801-TA CT801-SI, CT801-TA Maintenance Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Maintenance Manual CT801-SI, CT801-TA

More information

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.: Smart level probe type APC-2000ALW/L Programmable zero shift, range and damping ratio 4...20 ma output signal + HART protocol Accuracy 0,16% Local display Intrinsic safety certificate (ATEX, IECEx) II

More information

VG5 Supplementary instructions

VG5 Supplementary instructions VG5 Supplementary instructions 2-wire / 10 GHz Radar (FMCW) Level Meter Supplementary Instructions for ATEX applications HYCONTROL CONTENTS VG5 1 General safety information 4 1.1 Scope of the document...

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

DK46 - DK800 Supplementary instructions

DK46 - DK800 Supplementary instructions DK46 - DK800 Supplementary instructions Variable area flowmeter Device category II2G with electrical internals Additional Ex manual KROHNE CONTENTS DK46 - DK800 1 Safety instructions 3 1.1 General... 3

More information

Electronic gas volume corrector model DGVC-04

Electronic gas volume corrector model DGVC-04 Electronic gas volume corrector model DGVC-04 1. Introduction The following user s manual gives information about the installation, configuration, usage and storage of the electronic gas volume corrector

More information

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 XA01537F-A/00/EN/01.16 71333275 Products Solutions Services Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 0Ex ia IIC T6 Ga X Ga/Gb Ex ia IIC T6 X Document: XA01537F-A Safety instructions

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

FTC130 Transmitter. Operating Manual

FTC130 Transmitter. Operating Manual Seite 1 von 11 FTC130 Transmitter Fast Thermal Conductivity Analyzer Operating Manual 1.09KD180724CWI1V05 Messkonzept GmbH Seite 2 von 11 1. Intended Use... 3 2. Description... 4 3. Measuring gases and

More information

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2. Introduction 1 Safety instructions 2 SITRANS Pressure transmitter SITRANS P, Z series for gauge and absolute pressure 7MF1564 Description 3 Assembly and connection 4 Technical data 5 Dimensional drawings

More information

Operating Instructions of BROSA tension load cells, types 0111, 0113

Operating Instructions of BROSA tension load cells, types 0111, 0113 Operating Instructions of BROSA tension load cells, types 0, 03. Description of BROSA tension load cells. Structure and function The BROSA type 0 and 03 tension load cells transmit and measure the tensile

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0. Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:

More information

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection

More information

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

Air Sensor. FCS Ex. Manual. AQ Elteknik AB Air Sensor FCS Ex Manual AQ Elteknik AB Air Sensor Model FCS Ex Manual version 2.0 Oct 2010 AQ Elteknik AB AQ Elteknik AB Air Sensor Manual 2 Table of contents 1. Manufacturer information... 4 Manufacture

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 9 5 14 40 35 11 9 5.4 M20 x 1.5 0102 S Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting Satisfies

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up

More information

Relative pressure transmitter type 520

Relative pressure transmitter type 520 Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the

More information

Intrinsically safe solenoid valves on/off controls - ATEX certification

Intrinsically safe solenoid valves on/off controls - ATEX certification www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 9 5 40 35 14 11 9 5.4 M20 x 1.5 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting Satisfies machinery

More information

Supplementary Installation and Operating Instructions. Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex. Category: II 2G Ex IIC II 3G Ex IIC

Supplementary Installation and Operating Instructions. Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex. Category: II 2G Ex IIC II 3G Ex IIC Supplementary Installation and Operating Instructions Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex Category: II 2G Ex IIC II 3G Ex IIC Contents 1 General safety directions...3 2 Main safety features...4

More information

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB Air Sensor SAC Ex Manual AQ Elteknik AB ATEX Air Sensor SAC Ex ATEX Certified model Manual version 2.1 April 2014 AQ Elteknik AB 2 Table of contents 1. Manufacturer information... 4 Manufacture Declaration

More information

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm Dimensions M30x1,5 5 40 37 0102 Model Number 36 LED Features Comfort series 10 mm embeddable Connection BN BU Accessories BF 30 Mounting flange, 30 mm L+ L- Technical Data specifications Switching element

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry Operating Instructions for Intrinsically Safe ressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry Contents 1. Introduction 2. Abbreviations, symbols 3. Important

More information

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6 P9000 High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESCRIPTION The P9000 Series is a range of advanced,

More information

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure

More information

Pressure switch KP-E. Data sheet

Pressure switch KP-E. Data sheet Data sheet Pressure switch KP-E KP-E pressure switches for use in refrigeration and air conditioning systems are equipped with SPDT gold plated contacts and stainless steel bellows. The high pressure switches

More information

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0. LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mho up to 0... 50 mho Output signals -wire: 4... 0 ma -wire: 0...

More information

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements

More information

Pressure switch, Differential pressure switch and Thermostat RT-E

Pressure switch, Differential pressure switch and Thermostat RT-E Data sheet Pressure switch, Differential pressure switch and Thermostat RT-E The RT-E series consist of pressure and differential pressure switches as well as thermostats. The units are designed for industrial

More information

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm Dimensions M18x1 37 40 4 0102 24 LED Model Number Features 5 mm embeddable Usable up to SIL2 acc. to IEC 61508 Connection BN BU Accessories L+ L- EXG-18 Quick mounting bracket with dead stop BF 18 Mounting

More information

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Supplementary Operator s Manual 42/24-14 EN Rev. 3 Advance Optima Continuous Gas Analyzers AO2000 Series with Uras26, Magnos206, Caldos25, Caldos27 Designed per Category 3G for Measurement of Flammable Gases ( Safety Concept ) and Non-flammable Gases Supplementary

More information

RTD temperature probes

RTD temperature probes RTD temperature probes Ex i for use in areas with an explosion hazard (Ex areas) Persons concerned: Experienced professional electricians as per EU Directive 1999/92/EC and trained personnel Operating

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 7 36 5 33.5 9 5.4 30 65 0102 Model Number Features Direct mounting on standard actuators Fixed setting Satisfies machinery directive Compact and stable housing EC-Type Examination Certificate

More information

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9 BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9 Issue: 9 22 nd March 2013 2 CONTENTS 1. Description 2. Operation 3. Intrinsic Safety Certification 3.1 ATEX certificate

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073 Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up to SIL2 acc. to IEC 61508 Accessories

More information

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection SG36KTL-M Quick Installation Guide This guide provides a general instruction of the installation procedures of SG36KTL-M. In no case shall this guide substitute for the user manual or related notes on

More information

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection SG33KTL-M Quick Installation Guide This guide provides a general instruction of the installation procedures of SG33KTL-M. In no case shall this guide substitute for the user manual or related notes on

More information

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Installation, operating and maintenance Instructions for Seemag bypass level indicator Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates

More information

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor Precision- Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

Mass Flow Meter (MFM) for gases

Mass Flow Meter (MFM) for gases Mass Flow Meter (MFM) for gases Type can be combined with Inline MFM for nominal flow rates from 25 l N /min to 1,500 l N /min; 1/4 to 3/4 High accuracy Fast settling time Fieldbus option Special version

More information

ADVANTAGES DESCRIPTION MECHANICAL FITTINGS AND DIMENSIONS

ADVANTAGES DESCRIPTION MECHANICAL FITTINGS AND DIMENSIONS 03304 Float Gauge: Level measurement Application: LNG tanks Level 03304 E 1 ADVANTAGES - High level accuracy - Local mechanical counter read out. - High reliability - Suitable for 12 and 8 still well.

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

Pressure Switches Application Guideline

Pressure Switches Application Guideline Pressure Switches Application Guideline Product Overview The Fema Pressure Switch product portfolio provides devices suitable for many applications. The portfolio contains Special functions and equipment

More information

PH01 Perfusion Cannula Manual

PH01 Perfusion Cannula Manual PH01 Perfusion Cannula Manual Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted without the express written permission of Multi

More information

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review) Certificate Number: MASC MS/11-127X Issue: 09 October 2017 Expire: 09 October 2020 Page: 1 of 5 IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

More information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

STARLOG. Capacitive Water Depth Probe

STARLOG. Capacitive Water Depth Probe STARLOG Capacitive Water Depth Probe Model 6521 User Manual Supplement 6219 Revision D July 10. 1998 Copyright Notice Copyright Unidata Australia 1998. All rights reserved. No part of this publication

More information

Level transmitter LT 100

Level transmitter LT 100 KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

Further technical information is available on

Further technical information is available on 1 of 5 Manufacture address : Bartec Technor AS Dusavikveien 39 4007 Stavanger Norway Further technical information is available on www.bartec-technor.no Note on instructions When working in hazardous areas,

More information

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0. Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

Pressure control, differental pressure control and thermostat Type RT

Pressure control, differental pressure control and thermostat Type RT MAKING MODERN LIVING POSSIBLE Technical brochure Pressure control, differental pressure control and thermostat Type RT Hydrocarbons www.danfoss.com/hydrocarbons Contents Page Introduction...3 Approvals...3

More information

SDI mA Pressure Transducer (Submersible + Dry) Model WL2100 Operating Manual

SDI mA Pressure Transducer (Submersible + Dry) Model WL2100 Operating Manual SDI-12 + 4-20mA Pressure Transducer (Submersible + Dry) Model WL2100 Operating Manual (Submersible) WL2100W (Dry) WL2100D QUALITY SYSTEM ISO: 9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD 48-50 Scrivener St,

More information

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE 1 These instructions generally describe the installation, operation, and maintenance of subject equipment. The manufacturer reserves the right

More information

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition Depth sensor Product reference : 90-60-456 REV 1 USER GUIDE and INSTALLATION GUIDE nke Sailing competition Z.I. Kerandré Rue Gutenberg 56700 HENNEBONT- FRANCE http://www.nke.fr After sale service n 33

More information

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual Air Bubbler Depth Gauge DG2200 Installation and Reference Manual Rev. 3.2.2 06/2011 Installation and Reference Manual Page 2 Contents Chapter 1: Installation and Overview... 3 1.1 DG2200 Location Diagram...

More information

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING Please Note: Ranges above 500mbar are designed and manufactured in accordance with sound engineering

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

MPM426W/436W Submersible Level Transmitter

MPM426W/436W Submersible Level Transmitter /436W Submersible Level Transmitter Features Full sealed stainless steel construction for submersible part; sensor and amplifier circuit are all in the sealed housing; protection class IP68; Aluminum-alloy

More information

Torque Tube TB300 Digital Transmitters

Torque Tube TB300 Digital Transmitters Page 1 of 7 7E.300-E Issue 4-2009 Description Series TB300 torque tube liquid level instruments utilize the buoyancy exerted on a displacer when immersed in a liquid. The buoyancy on the displacer is proportional

More information

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars. Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis

More information

Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable

Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable GEP-6075 Rev. B 101574 Ref. I.D.: 16973 Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable WARNING USER SHOULD READ AND THOROUGHLY UNDERSTAND THESE

More information

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration 4 Digit Display, 4-20mA Output Instruction Manual (Digital Differential Pressure Transmitter) 1. General Specification 2. Installation 3. Wiring 4. Function 5. Setting & Calibration 1 4 20 1 Differential

More information

Maintenance Manual. Electropneumatic Level Measuring System TYPE TN3801

Maintenance Manual. Electropneumatic Level Measuring System TYPE TN3801 TYPE TN3801 Maintenance Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Maintenance Manual TYPE TN3801 1 st Edition

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm non-flush Stainless steel housing Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching element function NAMUR, NC Rated operating

More information

Datasheet: K-30 ASCII Sensor

Datasheet: K-30 ASCII Sensor Datasheet: K-30 ASCII Sensor The K30 ASCII sensor is a low cost, infrared and maintenance free transmitter module intended to be built into different host devices that require CO2 monitoring data. The

More information

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

MANUAL KPS Pressure Control Valve

MANUAL KPS Pressure Control Valve TetraTec Instruments GmbH Gewerbestrasse 8 71144 Steinenbronn Deutschland E-Mail: info@tetratec.de Tel.: 07157/5387-0 Fax: 07157/5387-10 MANUAL Pressure Control Valve *** VERSION 1.0 *** Update: 17.11.2006

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication

More information

Coriolis Mass Flow Meter

Coriolis Mass Flow Meter Coriolis Mass Flow Meter TMFW Series Mini Type Coriolis Mass Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com;

More information

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant

More information

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant

More information

AMS 2710 PCB pressure sensor module with V output

AMS 2710 PCB pressure sensor module with V output FEATURES Universal pressure sensor module with 0.. 10 V voltage output Fully calibrated and temperature compensated sensor module Variants for (bidirectional) differential, gage, absolute and barometric

More information

Pneumatic pressure switch 20DD

Pneumatic pressure switch 20DD Sensor system: stainless steel 0,2 to 6 bar Microswitch with gold plated contacts (suitable for intrinsically safe operation) High accuracy (max. scattering < 1,5%) Excellent sealing properties (better

More information

Dual Solenoid Gas Valve Installation

Dual Solenoid Gas Valve Installation Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions

More information

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-12 Quick mounting bracket with dead stop BF 12 Mounting flange, 12 mm Technical Data specifications Switching

More information

HBLT-A1 LIQUID LEVEL SENSOR

HBLT-A1 LIQUID LEVEL SENSOR Instruction manual HBLT-A1 LIQUID LEVEL SENSOR for measuring liquid level in refrigerant vessels Instruction manual HBLT - A1 - Liquid level Transmitter (HBLT-A1-008-UK) 1 / 16 Contents Safety instructions...

More information

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520 Operating instructions Contents EN Pressure switch, heavy-duty version Model PSM-520 1. General information 2. Design and function 3. Safety 4. Transport, packaging and storage 5. Commissioning, operation

More information

Technical Explanation

Technical Explanation Technical Explanation for ESI Pressure Sensors Technical Explanation What is a pressure transmitter? A pressure transmitter (also called pressure transducer or pressure converter) is a component used to

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features Comfort series 30 mm non-flush Accessories MHW 0 Modular mounting bracket V-G Female connector, M, 4-pin, field attachable V-W-N-M-PUR Female cordset, M, -pin, NAMUR, PUR cable

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

Liquid level instruments BM 24 /BM 51

Liquid level instruments BM 24 /BM 51 KROHNE 09/2001 7.02362.21.00 GR/PRINTO Liquid level instruments / Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

TECHNICAL MANUAL DHR60 LED. Den Haan Rotterdam MED96/98/EC

TECHNICAL MANUAL DHR60 LED. Den Haan Rotterdam MED96/98/EC TECHNICAL MANUAL DHR60 LED MED96/98/EC SINCE 1922 Den Haan Rotterdam DISCLAIMER Despite constant care and attention DHR puts in its manuals it is still possible that information in this manual is incomplete

More information

NivuBar Plus II

NivuBar Plus II NivuBar Plus II Ceramic diaphragm Capacitive measuring cell 2-wire technology (output 4-20 ma) Integrated overload protection Extensive, almost front flush diaphragm Ex approval for zone 0 as standard

More information

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

D10S/D20S Wall/Post Mount Inflator Quick Start Manual PART NUMBER SERIAL NUMBER D10S/D20S Wall/Post Mount Inflator Quick Start Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product

More information