ThermaSkirt A N E C O R E V O L U T I O N I N R O O M H E A T I N G
|
|
- Mervyn Johnston
- 5 years ago
- Views:
Transcription
1 DOUBLE TRV TEMPLATE (Sheet 1 of 2) Through floor pipework (Left and right feed) mm 1 Relieve plaster/ surface finish to a depth of in this shaded area to allow for Tectite fittings 4 Relieve plaster/surface finish to a depth of 2 in this dark shaded area to allow feed pipe to go behind Tectite fitting 1 60mm 9 Cut/fold along here for Urban LT template Cut/fold along here for Regency OG template (See sheet 2 for location) TM I N S TA L L AT I O N Page 1 1. P O S I T I O N F E E D P I P E S ISSUE 14 / November 2009 (Download further copies at ThermaSkirt A N E C O R E V O L U T I O N I N R O O M H E A T I N G These instructions are intended as a guide only. Your installation & design may vary - if in doubt ask for help. DiscreteHeat Co. Ltd. accept no liability for any errors or omissions. If you have any tips or suggestions them to: toptips@discreteheat.co.uk TOOLS YOU WILL NEED: A suitable metal cutting saw, preferably a chop saw (only if cutting lengths on site) / A DiscreteHeat rotary de-burring tool / An accurate quality tape measure (Stanley, DeWalt etc.) / String line and chalk or laser level / A Stanley knife and/or plasterboard saw / Power drill with hammer action / Power driver / Size 10 screws (50-) / Plastic or timber faced mallet / Rawlplugs and\or plasterboard fixings / Pipe cutting tool (10mm/1/16mm) / Various push fit connectors / Your plan and cutting list (if purchased as a room kit). ALL EXAMPLES SHOWN ARE CLOCKWISE S. THE SAME DIMENSIONS AND SPACINGS APPLY TO ANTI-CLOCKWISE S. Remember to allow for carpet or tiles if NOT Finished Floor Level REGENCY OG (8in / 200mm) URBAN LT (6in / 150mm) DECO PR (5in / 12) 4 1 Feed and Return pipes tight to wall CLOCKWISE SHOWN PIPE FITTINGS NEED TO BE SET INTO THE SINGLE TRV Relieve plasterwork x to a depth of BI-DIRECTIONAL TRV Relieve plasterwork 150mm x to a depth of 150mm Feed 1 (16mm to order) Return 1 (16mm to order) FOR TEMPLATES VISIT
2 TM Page 2 2. CUTTING SKIRTING TO LENGTH (when not supplied pre-cut) RF L 1 50mm L 9 = (L 9-150mm) = (L 1-150mm) = (L 2-60mm) = (L 3 -) L 2 Archway, patio, door obstruction, etc. (Threshold Kit) CLOCKWISE SYSTEM SHOWN = (L 4-0~) L 4 L 3 L 5 = (L 5 -) L 8 = (L 8-1) = (L 7-60mm) = (L 6-60mm) L 6 24 TPI minimum L 7 (5") (1 1 / 4 ") 0~ (0.0") 50mm (2") 50mm (2") (4") 50mm (2") 20mm ( 3 / 4 ") Deburring tool (Part No. STOOL) Bell Mouth deburr DEBURR Keep parallel x10 Remove all chaff and debris
3 TM Page 3 3. MOUNTING CHANNEL - LT AND OG PROFILE ONLY? Make sure you allow for uneven/unlevel floors. Bottom cover should be trimmed first. Pencil Line C C L L STRING LINE & CHALK Push in 60mm Chalk Line 8 Chalk Line 90 Click down URBAN LT REGENCY OG URBAN LT & REGENCY OG ONLY 150mm 600 ~ 1,000mm ± Insulating foil, if required (Part No. INSRL LT or INSRL OG) (older, solid walls without cavity) DECO PR Minimum active length = 50mm (2") Mounting brackets can be cut for smaller sections
4 = = TM Page 4 4. SEQUENCE CLOCKWISE SHOWN View on back of TRV showing fixings DO NOT OVERTIGHTEN Feed Return Internal Corner 40mm External Corner 20mm 20mm CLICK 30 ~ 40mm ENSURE BOTH SIDES ARE LEVEL WITH EACH OTHER PUSH CLICK, CLICK, CLICK 20mm max. STAINLESS STEEL C/SUNK FIXING SCREW RECOMMENDED
5 TM Page 5 5. CORNERS AND COVERS Trim 1 Spraying channel with water or furniture polish can help fitting 2 ENSURE BOTH SIDES ARE LEVEL WITH EACH OTHER Peel off Super Velcro backing Cover can be warmed on the back to adjust the angle and ease fitting (Overheating will cause damage) 1 Pz x 2 Check back of cover is clean and free from grease Pz1 Position holes in knob as shown to access 2 fixing screws for TRV controls 2 6. FINAL CHECKS 1 ~ 2 bar 2 1 Clockwise Installation OFF AIR OFF OFF TRV Unit Anti-clockwise Installation Return Manifold A pressure test of the system before connecting to the central heating system is recommended. (See part no. TTEST) TECHNICAL SPECIFICATION Material Output (per dt50 C) Feed & Return Weight Capacity Corrosion Min. Flow Surface Complies Recommended BTU / W Pipe Kg per m Litres per m Resistance Rate Finish with Max. Operating Temp. Unique Polymer & LT > 500BTU / 150W 1 1.4kg LT 0.5 l/m Excellent 10 c.c. per sec Epoxy Powder BS-EN 80 C Aluminium Alloy OG > 700BTU / 210W 16mm to order 1.7kg OG See Section litre/min to BS-EN PR > 450BTU / 135W 1.2kg PR Running your system
6 TM Page 6 7. RUNNING YOUR SYSTEM Run the system at fully open, maximum temperature for 1 hour, to expel any air in the system. Release any air that may be trapped at appropriate radiator bleed points and return manifold bleed point. Turn off TRV/flow manifold and allow to cool. Set to desired room setting and run normally. NOTE: DiscreteHeat recommend flushing the system with ThermaSkirt Cleanser TS3 or alternatively Scalemaster SM3 (check dosage carefully) and running with ThermaSkirt corrosion inhibitor TS5 or alternatively Scalemaster SM1 (check dosage carefully) to ensure maximum longevity and reliability. Hard water areas may require additional precautions. Chemically softened water must NOT be used. This is a standard precaution for ALL wet heating systems. Contact DiscreteHeat for specific application advice. 8. TROUBLE SHOOTING PROBLEM CAUSE SOLUTION Leak at joint. Faulty / incorrect installation Drain and replace fitting or O ring from spares kit. ThermaSkirt not hot. Check boiler. Is heating ON and pressure OK? Lockshield valve closed. Open Lockshield valve ( ). TRV valve closed / off. Open TRV valve ( ). Air trapped in pipework. See 9 below. Water from Manifold not closed fully. Turn to OFF position. Return Manifold. 9. BLEEDING YOUR SYSTEM As ThermaSkirt acts like a pipe, in normal operation air does not get trapped. However, on existing systems, to which ThermaSkirt is added, air may get trapped in the existing pipework to and from the skirting. Follow these simple steps if you discover cold sections of the ThermaSkirt which do not heat up. CLOSE 1. Existing System with Conventional Radiators. Turn off all radiators and ThermaSkirt thermostatic and lockshield valves. Make sure your system is fully pressurised and the pump is set to max. Run the system for a few minutes, and, starting from the lowest point in the house, open each radiator/thermaskirt system, one at a time. Run for a further 2 minutes (approx), close again and move to the next ThermaSkirt or radiator, moving upwards in the house. Any air will be expelled through the boiler or trapped in a conventional radiator. Bleed the radiator as normal. Trapped air expelled through boiler Existing System with Conventional Radiators TRV Unit CLOSE 2. New Installation with ThermaSkirt Only. On installation, in a convenient place at the highest point of the system, T off into a vertical leg 600mm high and install an automatic/manual air vent. Following the procedure above, close and open each ThermaSkirt system in turn. Any air forced round the system will be expelled through the boiler or through the air vent. Air can also be bled from the bleed screw on top of the return manifold (A). 600mm (min) Trapped air expelled through boiler New Installation with ThermaSkirt Only A
7 LH END LH END clockwise installation Cut along dotted line SINGLE TRV TEMPLATE) (Through floor pipework) Fax: web: mm RH END anti-clockwise installation 9 Fold along here for Deco PR template Fold along here for Urban LT template Relieve plaster/ surface finish to a depth of in this hatched area to allow for Tectite fittings (PR) 4 (LT) (OG) (PR) (LT) touching wall surface 1 (OG) Fold along here for Regency OG template touching wall surface Plan view for drilling feed and return pipe holes in floor DOUBLE TRV TEMPLATE (Sheet 1 of 2) Through floor pipework (Left and right feed) mm 1 Relieve plaster/ surface finish to a depth of in this shaded area to allow for Tectite fittings 4 Relieve plaster/surface finish to a depth of 2 in this dark shaded area to allow feed pipe to go behind Tectite mm Cut/fold along here for Urban LT template Cut/fold along here for Regency OG template (See sheet 2 for location) STICK TO TO USE fitting Cut/fold along here (Place on end of wall or doorway architrave) Cut/fold along here (Place on end of wall or doorway architrave)
8 80mm mm (Through floor pipework) THRESHOLD KIT PIPE TEMPLATE 80mm 50mm LH END 50mm RH END (PR) 80mm 80mm Fold along here for Regency OG template touching wall surface Plan view for drilling feed and return pipe holes in floor touching wall surface 32mm 32mm Cut/fold along here (Place on end of wall or doorway) Cut/fold along here (Place on end of wall or doorway) LH and RH installation Relieve plaster/surface finish to a depth of in this hatched area to allow for Tectite fittings Fax: info@discreteheat.co.uk web: Fold along here for Deco PR template Fold along here for Urban LT template 1 (OG) (OG) (LT) 4 (LT) (PR) DOUBLE TRV TEMPLATE (Sheet 1 of 2) Through floor pipework (Left and right feed) mm 1 4 Relieve plaster/ surface finish to a depth of in this shaded area to allow for Tectite fittings Relieve plaster/surface finish to a depth of 2 in this dark shaded area to allow feed pipe to go behind Tectite fitting mm Cut/fold along here for Urban LT template Cut/fold along here for Regency OG template (See sheet 2 for location) STICK TO TO USE
M03 WUNDATRADE. Heat Pump Manifold. Before you start: Check the contents. Optional. ...a division of WUNDA GROUP PLC
Before you start: Check the manifold box contents against the list below. Check the contents Flow gauges 1. Bar assembly with manual return valves 2. 2 x Auto air vent & drain hose attachments Optional
More informationSEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER
SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER CONTENTS 1. INTRODUCTION & SAFETY 1 2. DIMENSIONS 2 3. TECHNICAL DATA 3 4. OPERATION 4 5. COMPONENTS 5 6. SITE INSTALLATION
More informationSystem Pressure Manager Standard & System Pressure Manager Plus
System Pressure Manager Standard & System Pressure Manager Plus Installation, Commissioning & Servicing Instructions Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,
More informationBASIN AND WALL MIXER INSTALLATION INSTRUCTIONS
BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION IMPORTANT All tapware and showers to be installed by a licensed plumber and to Australian Standards. Fit tempering and pressure reduction
More informationSTAP. Differential pressure controller DN 15-50
Differential pressure controller 15-50 Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE is a high-performing differential pressure controller that keeps the
More informationElectronic Single and Twin Pump System Pressure Managers
Electronic Single and Twin Pump System Pressure Managers Installation, Commissioning & Servicing Instructions Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING, OPERATING
More informationambiente Installation Guide AmbiPlate more than underfloor Customer: Project: Project Reference: Date:
ambiente more than underfloor Customer: Project: Project Reference: Installation Guide AmbiPlate 0 0 Date: Ambiplate installation guide AmbiPlate Series Contents Designed for joisted/battened floors Maximum
More informationDatasheet liniled Handrail 48.3 V1017 IK10 IP68. F RoHS IP40/IP65 FROST CLEANING AGENTS RESISTANT UV RESISTANT
Datasheet liniled Handrail 4 V1017 F RoHS IP40/IP65 IP68 IK10 AISI 316 UV RESISTANT FROST CLEANING AGENTS RESISTANT Handrail 4 Product information Technical specifications Product specifcations Required
More informationDeluge Optimo Shower valve and kit 10032CP
Deluge Optimo Shower valve and kit 10032CP Installation, Operation and Maintenance Please leave these instructions with the user Intatec Limited Airfield Industrial Estate, Hixon, Staffordshire, ST18 0PF
More informationTwin & Triple Control Concealed Thermostatic Shower Valve
Twin & Triple Control Concealed Thermostatic Shower Valve Installation & Operating Guide Please leave this installation & user guide with the end user CONTENTS: 1. Introduction & Safety 1 2. Dimensions
More informationOWNER S GUIDE DUAL CONTROL THERMOSTATIC SHOWER VALVE. Shower Control. may differ depending on choice of Model. Concealing Plate. Handles and ISSUE 01
DUAL CONTROL THERMOSTATIC SHOWER VALVE Shower Control Handles and Concealing Plate may differ depending on choice of Model OWNER S GUIDE ISSUE 01 These instructions cover all exposed or concealed versions
More informationHORNE T109A/306A/307A THERMOSTATIC SHOWER VALVE FOR SURFACE MOUNTING WITH TIMED FLOW CONTROL INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS
Horne Engineering Ltd PO Box 7, Rankine Street Johnstone, PA5 8BD Tel: +44 (0)1505 321455 Fax: +44 (0)1505 336287 Email: Technical@horne.co.uk Web: www.horne.co.uk HORNE T109A/306A/307A THERMOSTATI SHOWER
More informationPOP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS
POP Safety Valve POP Safety Valve INTRODUCTION The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both plant and personnel. Safety
More informationTECHNICAL DATA. Trimpac 244a. September 16, 2013
September 16, 2013 Trimpac 244a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-1 and B-1B is a factory-assembled trim package with an electric release module in a metal enclosure. The standard trim normally
More informationAREA VALVE SERVICE UNITS
AREA VALVE SERVICE UNITS. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com U.K., SK3 0SB www.p3-phoenix.com
More informationDatasheet liniled Handrail 42.4 V1017 IK10. F RoHS FROST CLEANING AGENTS RESISTANT UV RESISTANT
Datasheet liniled Handrail 42.4 V1017 F RoHS IP40 IP68 IK10 AISI 316 UV RESISTANT FROST CLEANING AGENTS RESISTANT Handrail 42.4 Product information Technical specifications Product specifcations Required
More informationExpansion Vessels for Potable Installations
4. Expansion Vessels for Potable Installations Domestic installations lose millions of litres of potable water due to expansion water leaking from the vent and expansion pipe. Flamco s Airfix diaphragm
More informationAutomatic balancing valves
Automatic balancing valves ASV DN 15-50 (4th gen.) ASV-PV ASV-BD ASV-M DN 15-50 DN 15-50 DN 15-50 Description ASV whiteboard animation ASV valves are automatic balancing valves. Together with Danfoss presetting
More informationSEries 29 Hydrant valves installation, operation & maintenance manual
Instruction for use Thank you for selecting an AVK product. With correct use, it will give long and reliable service. This manual has been prepared to assist you install, operate and maintain the valve
More informationSTAP. Differential pressure controller DN
STAP Differential pressure controller DN 65-100 Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE The flanged STAP is a high-performing differential pressure
More informationSeries IRV1000/2000/3000
CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one
More informationBar valve with fixed shower head Installation guide
Midas Plus Mono Bar valve with fixed shower head Installation guide Midas Plus Mono Midas Plus Mono Components Literature not shown Important information Introduction The Midas Plus Mono product is an
More informationTECHNICAL DATA. TRIMPAC Model B-5 & B-5B
September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on
More informationSIMPLAIR PIPING TOOL. JXT Company
SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.
More information776 Cryogenic Safety Valve
776 Cryogenic Safety Valve INTRODUCTION 776 Cryogenic Safety Valve The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both plant
More informationSelf-help Temperature Adjustment
Self-help Temperature Adjustment The Shower Valve temperature is pre-set to 42 C, but on certain installations the temperature may need to be adjusted. Note: The hot water supply must be above 60 C. Turn
More informationambiente Installation Guide AmbiScreedboard system more than underfloor Customer: Project: Project Reference: Date:
ambiente more than underfloor Customer: Project: Project Reference: Installation Guide AmbiScreedboard system Date: AmbiSCREEDBOARD installation guide AmbiSCREEDBOARD Series Contents Slimline 18mm board
More informationOUS31. Technical Information
Technical Information OUS Turbidity sensor Installation and immersion sensor for drinking water and industrial water according to the 90 scattered light method Application All phases of drinking water
More informationURINAL FLUSHING SYSTEM WITH MICROWAVE SENSOR
URINAL FLUSHING SYSTEM WITH MICROWAVE SENSOR Installation & Maintenance Instructions EMF303M I00013_Aug 15 Call 1300 369 273 www.enware.com Enware Australia Pty Limited 9 Endeavour Rd Caringbah NSW 2229
More informationTECHNICAL DATA. Trimpac 251a. Spetember 16, 2013
Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release
More informationThese instructions are to be left with the user
MIRA GEM 88 SHOWER CONTROL Installation & User Guide These instructions are to be left with the user CONTENTS Introduction... 3 Important Safety Information... 4 Pack Contents Checklist... 5 Dimensions...
More informationFILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS
FILTER REGULATORS MODEL NO: CAT155 & CAT156 PART NO: 3120169 & 3120170 FITTING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0117 INTRODUCTION Thank you for purchasing this CLARKE Filter/Regulator.
More information756 Safety Relief Valves
756 S a fe t y R e l i e f Va l ve s INTRODUCTION 756 Safety Relief Valves The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both
More informationSealed Systems Altecnic Ltd - Caleffi group. Sealed Systems. Heating vessel sizing guide
1.25 Sealed Systems Sealed Systems Sealed primary central heating systems are the most commonly used form of heating system throughout Europe and the rest of the developed world. Sealed central heating
More informationbook : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer
955751.book : t95575.fm Seite 1 Mittwoch, September 20, 2000 10:10 AM Avensys Exposed Single Lever Mixer 33 389 33 396 Installation Instructions and Operating Guide Please leave this document with the
More informationINSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM
INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM Valve Model No's: 1-741, 1-742, 1-743, 1-744 1-741 1-742 1-743 1-744 2001 CARNEGIE AVE, SANTA ANA CA 92705 (949) 417-5207 WWW.NEWPORTBRASS.COM
More informationLUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS
AIR FILTER, REGULATOR AND LUBRICATOR 4035 ASSEMBLY AND OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com Copyright 004 by Harbor Freight
More informationOverhead Irrigation Installation Guide DOM Copyright First Tunnels Ltd 2012.
www.firsttunnels.co.uk/quality Overhead Irrigation Installation Guide DOM Copyright First Tunnels Ltd 2012. Warnings General Please keep children and pets away from the work area. If any holes are not
More informationCalCheck. Instrument User Manual V1.8
CalCheck Instrument User Manual V1.8 Unrivalled Part number: 21518 Detection. Part number: 21518 Declaration of conformity Manufacturer:, The Way, Fowlmere, Cambridge, England. SG8 7UJ Product: CalCheck
More informationWelker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct
More informationMODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL
MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL Index 1. List of components / General arrangement 2. Description 3. Handling 4. Installation 5. Actuators / Operation 6. Maintenance a. Changing
More informationK13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS
K13 DOORS K13.12 FACE FIXED PANIC EXIT DEVICE 01.03.2018 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com CONTENTS 1. Base set n
More informationMainsboost Installation, Operation & Maintenance Instructions
mainsboost Mainsboost Installation, Operation & Maintenance Instructions Please leave this instruction booklet with the home owner as it contains important guarantee, maintenance and safety information
More informationBourdon tube pressure gauges for chemical applications EN 837-1
Application For aggressive gaseous and liquid media which are not highly viscous and do not crystallize. Suitable for use in corrosive atmospheres.! When measuring gas or vapour, the instruments must be
More informationCLEANROOM GEL GRID CEILING SYSTEM PRODUCT DATA Division
5023 HAZEL JONES ROAD, BOSSIER CITY, LA 71111 888.315.1561 800.877.8746 FAX SALES@GORDONCLEANROOM.COM GORDONCLEANROOM.COM AN EMPLOYEE OWNED COMPANY CLEANROOM GEL GRID CEILING SYSTEM PRODUCT DATA Division
More informationF13.11 PARALLEL HINGES F13 PROJECT-OUT WINDOWS AND TOP HUNG WINDOWS
F13 PROJECT-OUT WINDOWS AND TOP HUNG WINDOWS F13.11 01.06.2018 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com CONTENTS 1. General...F13.11.03
More informationPC3_ and PC4_ Pipeline Connectors
1283050/4 IM-P128-06 ST Issue 4 PC3_ and PC4_ Pipeline Connectors Installation and Maintenance Instructions 1. Safety information 2. Description PC30 shown 3. Installation 4. Welding of pipeline connector
More informationBourdon tube pressure gauges with glycerine filling, for chemical applications EN 837-1
Application For aggressive gaseous and liquid media which are not highly viscous and do not crystallize. Suitable for use in corrosive atmospheres. For measurement in areas subject to high vibration levels
More informationInternal Sealing of Masts
595-814-E 2007-02-15 Internal Sealing of Masts (Replaces the sealing instructions 595-551-SE) Vertical high line Kicker bracket Sec. sealing hole Drain hole Conventional masts This instruction is enclosed
More informationHorne Engineering Ltd
Horne Engineering Ltd Po Box 7, Rankine Street Johnstone, Renfrewshire Scotland, PA5 8BD Tel: 01505 321455 Fax: 01505 336287 Email: technical@horne.co.uk Web: www.horne.co.uk HORNE T105A/106A/107A/108A
More informationPLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions
PLAQUE MFM0680 UNDERWATER LIGHT Operating Instructions CONTENTS Preface... 3 Features... 3 Precautions... 3 Controls and Connectors... 4 Underwater Light PLAQUE MFM0680... 4 Power Supply Unit MPS021000
More informationHalsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!
Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4410FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY ARE LOCATED
More informationHalsey Taylor Owners Manual STOP!
Halsey Taylor Owners Manual 4710 Freeze Resistant Floor Mounted Steel Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4710FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY
More informationMainsflush Troubleshooting Guide
Mainsflush Troubleshooting Guide Problem Possible Causes Action Flush volume is either too low or too high. Flush causes splashing over front of pan. Flush volume/flow rate is insufficient to clear waste.
More information36H SERIES Combination Gas Valve
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION The 36H series combination gas valve is
More informationUltRo Dual Flow Reverse Osmosis Water System
UltRo Dual Flow Reverse Osmosis Water System Congratulations on this great investment to your health. **IMPORTANT NOTE BEFORE YOU BEGIN** We recommend you call your local friendly plumber to ensure proper
More informationAquor House Hydrant V2
Aquor House Hydrant V2 IN-WALL OUTDOOR FAUCET SYSTEM FLUSH-MOUNT QUICK-CONNECT SELF-DRAINING ANTI-SIPHON NON-FREEZE VBH-SERIES AQUOR HOUSE HYDRANT V2: WALL HYDRANT / FREEZELESS SILLCOCK Freezeless sillcock
More informationPO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:
EZI-DRY Pty Limited ABN: 98 114 507 443 PO Box 370 Phone: 0249711993 Swansea NSW 2281 Fax: 0249135490 AUSTRALIA Mobile: 0427587900 Web: www.ezi-dry.com.au Email: ezidry@exemail.com.au INSTRUCTION MANUAL
More informationTECHNICAL ACCESSORIES
A.R.I. VALVES S-050P AIR PLASTIC RELEASE 16 BAR Automatic Component A.R.I patent, Rolling Seal Mechanism: Dramatically reduces the possibility of obstruction by debris. Discharges high air flow rates upto
More informationTWO POST RAM PACKAGE 55 GALLON
OPERATOR S MANUAL TP1265S5XXXXXXXX INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE. INCLUDE MANUALS: AF1265SXXXXXX Extrusion Pump (97999-1528), RM552X-XXX-XX Two Post Lift / Ram (pn 97999-1445), & S-636
More informationUSG Ceiling Solutions. LOGIX Integrated Ceiling Systems INSTALLATION GUIDE
USG Ceiling Solutions LOGIX Integrated Ceiling Systems INSTALLATION GUIDE LOGIX Integrated Ceiling Systems INSTALLATION GUIDE Logix Brand Integrated Ceiling Systems integrated ceiling systems from USG
More informationSunrise Fountain Water Wonders Assembly & Mounting Instructions
Welcome to the Water Wonders family. A few simple steps will ensure that your Sunrise Fountain remains a soothing, enjoyable fountain that brings the sights and sounds of nature to you. Two important considerations
More informationOCEAN - Wellness Line
147 Modern and functional: The range for shower and sauna doors. CONTENTS Technical details 1-151 Materials and surface finishes 152 Product information Shower hinges 153 Connectors and shower door knobs
More informationSTA-F Description. STA-F Prefab insulation Measuring nipples
TA STA-F 5-5-1 5 Balancing valves September 1985 STA-F is a flanged balancing valve available in sizes DN 20-300, and has been designed with an oblique seat in order to give low resistance and large flows
More informationSteam Trap BK 15 (DN40, DN 50) Original Installation Instructions English
Steam Trap BK 15 (DN40, DN 50) EN English Original Installation Instructions 810682-03 1 Contents Page Important Notes Usage for the intended purpose... 4 Safety note... 4 Danger... 4 Attention... 4 Application
More informationPT 11 trouble-shooting and maintenance.
PT 11 trouble-shooting and maintenance. Does your rudder not stay down?...your back seat slip off?...your knobs tight and your leather pads loose? Maybe we can help. We have used our PT 11 s hard enough
More informationLatvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.
Product Specification ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.0 bar Latvin Luxury Shower Panel ~ Fixing Centres 150mm +/- 10mm ~ Outlet size 1/2" Bottom Outlet Always maintain a
More informationUSER INSTRUCTIONS. NAF Duball DL Ball Valves. Installation Operation Maintenance. Experience In Motion. flowserve.com
USER INSTRUCTIONS NAF Duball DL Ball Valves FCD NFENIM4167-01-A4 01/17 Installation Operation Maintenance 1 Experience In Motion Contents SAFETY 3 1 General 3 2 Lifting 4 3 Receiving Inspection 4 4 Installation
More informationImpeller Replacement -
10 www.jabsco.com Introduction Jabsco - The Original Impeller Jabsco flexible impellers can be fitted to most makes and models of bronze flexible impeller engine cooling, bilge, transfer and general purpose
More informationInstallation Guide - C01202 & C01203 Thermostatic Mixing Valve TMV2
The following information is required for use when the Saracen range of thermostatic mixing valves is used in a TMV2 Applications under the requirements of BS EN 1111: 1999 Sanitary tap ware Thermostatic
More informationREVERSE OSMOSIS INSTALLATION Watermark 4 Stage
REVERSE OSMOSIS INSTALLATION Watermark 4 Stage BRIEF TECHNICAL ASPECT OF THE WATER TREATMENT SYSTEM The Filter Systems Australia Water Treatment System utilizes a process called reverse osmosis (RO). As
More informationOperating Instructions
Operating Instructions Multifunction Valve Contents Page Safety Instructions... 2 Unpacking... 2 Introduction... 2 Dimensions... 4 Installation...2-3 Description of Controls & Operation... 3 Page Helpful
More informationINDUSTRIAL TRANSFER PUMPS
INDUSTRIAL TRANSFER PUMPS Diaphragm Transfer Pumps - Plastic Body Pumps - Metal Body Pumps - Hygienic Pumps - High Pressure Pumps - Powder Pumps PLASTIC BODY PUMPS Diaphragm pumps also run trouble-free
More informationMSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection
1170850/1 IM-P117-36 ST Issue 1 MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection Installation and Maintenance Instructions 1. Safety information 2. General product information
More informationDri-Line Mk3 Monnier Compressed Air Drain Trap
5044050/2 IM-P504-24 CH Issue 2 Dri-Line Mk3 Monnier Compressed Air Drain Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and Operation
More informationRotary Abreast Automatic Teat Sprayer User Manual. Technical Manual Revision 0.01
Rotary Abreast Automatic Teat Sprayer Technical Manual 006911 Revision 0.01 Contents Contents... 2 Important information - read this first... 3 Icons... 3 1. Introduction... 4 2. Intended Use... 4 3. General
More informationINSTALLATION, OPERATING & MAINTENANCE MANUAL WATER DRAIN VALVE
INSTALLATION, OPERATING & MAINTENANCE MANUAL WATER DRAIN VALVE Contents 1 Introduction 1. Introduction... 3 2. Specification... 4 3. Installation... 7 4. Operation...11 5. Maintenance...14 This Water Drain
More informationLigature Resistant Head
Ligature Resistant Head PRODUCT MANUAL IMPORTANT INSTALLER: This product manual is the property of the customer and must be retained with the product for maintenance and operational purposes. 1 Contents
More informationPressure Dump Valve Service Kit for Series 2300 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit
More informationambiente Installation Guide AmbiClip Systems more than underfloor Customer: Project: Project Reference: Date:
ambiente more than underfloor Customer: Project: Project Reference: Installation Guide AmbiClip Systems Date: AMBICLIP INSTALLATION GUIDE AMBICLIP FLOOR LAYING INSTRUCTIONS 1 Set up pipe decoiler and all
More informationPRODUCT CARD WALL MOUNTED SIDE FOLDED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,2 TO 2,45 M
PRODUCT CARD WALL MOUNTED SIDE FOLDED BASKETBALL CONSTRUCTION PROJECTION: FROM 1,2 TO 2,45 M I. List of components... 2 II. Complimentary products... 2 III. Product description... 3 IV. Product Purpose...
More informationPLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions
PLAQUE MFM18240 UNDERWATER LIGHT Operating Instructions CONTENTS Preface... 3 Features... 3 Precautions... 3 Controls and Connectors... 4 Underwater Light PLAQUE MFM18240... 4 Power Supply Unit MPS061000
More informationDS MB, MBF THREE PORT VALVES
DS 4.501 04/96, F THREE PORT VALVES Specification No. 617-X-XXX* F 618-X-XXX* and F valves are of the 3-port rotary-shoe type. They are characterised for use as mixing or diverting valves, with hot or
More informationProportional Throttle Cartridges, Size 16
Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact
More informationInstallation, commissioning and servicing instructions
488.03 www.reece.com.au Pressure reducing s Installation, commissioning and servicing instructions Function Pressure reducing s are installed in residential water systems to reduce and stabilise inlet
More informationTemperature Controllers
IM0004 April 2013 CONTENTS T-12 Thermostat PAGE Introduction 1 Scope 1 Description 1 Specification 1 Temperature Controllers 2 INTRODUCTION CAUTION Prior to installing, the instructions provided herein
More informationPressure and Flow Control Valves DBGM, German and European Patents
Pressure and Flow Control Valves DBGM, German and European Patents Absolutely Reliable Pressure and Flow Control In water mains of sizes DN 50 to DN 150, ERHARD Control Valves in straight or angle pattern
More informationbathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents
bathrooms.com Concentric Thermostatic Shower Mixers Contents Page 3 - General Information & Safety Page 4 - Installation Page 5 - Concentric Valve Set-up Page 6 - Exposed fitting of Concentric Mixer Valves
More informationDifferential pressure gauge For the process industry Model , all-metal media chamber
Pressure Differential pressure gauge For the process industry Model 732.51, all-metal media chamber WIKA data sheet PM 07.05 for further approvals see page 4 Applications For gaseous and liquid aggressive
More informationAPPROVED FOR USE IN SOUTH AFRICA STAINLESS STEEL STOVE
AUTOMATIC GAS COOKER TWO BURNER STAINLESS STEEL STOVE THIS IS A LOW PRESSURE APPLIANCE TO BE USED ONLY WITH A 2.8kPa APPROVED SANS 1237 REGULATOR. REGULATOR NOT INCLUDED. PLEASE READ THESE INSTRUCTIONS
More informationBall Valves for Heating and District Heating. Date 1
Ball Valves for Heating and District Heating Date 1 Underground Ball Valves DN 20 DN 600, PN25 Underground valves are installed in pre insulated pipe systems, transporting hot water from production to
More informationCRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES
CRP INSTALLATION, OPERATING AND MAINTENANCE INFORMATION FOR INLINE SAMPLING VALVES Sampling Valves Installation Commissioning and Operating Instructions SD IL 300 & SD IL 400 Inline Sampling Valve This
More informationPremium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.
Premium Series High Quality Forged Brass Body Rust-Resistant Nickel Plated Finish Long Life Corrosion Resistant Valve Seat Economical Price & Reliable Performance Tamper-Resistant locking Screw Reduces
More informationInstallation Instructions
48011HW NATURAL GAS TO PROPANE CONVERSION KIT 58HDX, 359AAV, PG9YAB, PG9YAA Installation Instructions SAFETY REQUIREMENTS Installing and servicing heating equipment can be hazardous due to gas and electrical
More informationEnerVal. Technical data litre storage capacity. Buffer storage vessels
EnerVal Buffer storage vessels Technical data 200-10000 litre storage capacity Contents Title Page number EnerVal (200-2000) Description 3 Part No. 4 Technical data 6 Dimensions 7 EnerVal G (1000-10000)
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated
More informationNEW TYPE M PRESSURE RELIEF DEVICE
NEW TYPE M PRESSURE RELIEF DEVICE M PRESSURE RELIEF DEVICE ACCORDING TO EN 50216-5/A2 PATENTED 2 PRESSURE RELIEF DEVICE TYPE 50 M Section A-A 170 139 Transformer tank F 41.5 3 ø48.3 ø166 A P.R.D. TAG A
More informationThese instructions are to be left with the user
MIRA EXCEL SHOWER CONTROL Installation & User Guide These instructions are to be left with the user 1 CONTENTS Introduction... 3 Important Safety Information... 4 Pack Contents Checklist... 5 Dimensions...
More informationMaximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications
Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range
More informationwater purification cylinders & accessories
water purification cylinders & accessories The exchange cylinder concept If you require purified water with low expenditure, then the SUEZ Cylinder Exchange Service is for you. Simply purchase the required
More information