EnerVal. Technical data litre storage capacity. Buffer storage vessels
|
|
- Branden Cross
- 6 years ago
- Views:
Transcription
1 EnerVal Buffer storage vessels Technical data litre storage capacity
2 Contents Title Page number EnerVal ( ) Description 3 Part No. 4 Technical data 6 Dimensions 7 EnerVal G ( ) Description 10 Part No. 11 Technical data 12 Dimensions 13 Notes
3 Description Buffer storage vessels EnerVal (200,300) Energy buffer storage vessel constructed of steel for hydraulic integration with heating boilers, heat pumps and solar energy systems Nominal content: 200, 300l 4 No. connection sockets Rp 1½ 1 No. socket Rp 1½ for screw-in electrical immersion heater 3 No. sockets Rp 1½ for sensor/thermometer Thermal insulation made of polyurethane soft foam with foil casing, colour red Buffer storage vessel with insulation and foil casing completely fitted and packed. Buffer storage vessel EnerVal (500) Energy buffer storage vessel constructed of steel for hydraulic integration with boilers, heat pumps and solar installations Nominal content 500l Inspection flange for solar heat exchanger, 225mm dia opening (not for EnerVal (2000)) 9 No. connection sockets Rp 1½ 5 No. sockets Rp ½ for screw-in type electrical immersion heater (not on EnerVal (2000) Thermal insulation made of polyurethane soft foam with foil casing, colour red Buffer storage vessel with insulation and foil casing completely fitted and packed. Buffer storage vessels EnerVal ( ) Energy buffer storage vessel constructed of steel for hydraulic integration with boiler, solid fuel boiler, heat pumps and solar installations Nominal content l 11 connection sleeves Rp 1½, on EnerVal ( ) as Rp 2 5 sleeves Rp ½ for sensor/thermometer 1 sleeve Rp ½ for screw-in electrical immersion heater Perforated separating plate in the central area for separation of the temperature zones Thermal insulation made of polyurethane soft foam with foil casing, colour red C C C Range EnerVal type Nominal content litres (200) 222 (300) 278 (500) 474 (800) 765 (1000) 956 (1500) 1365 (2000) 2039 Screw-in electrical immersion heater type EP-3 to EP-9 (optional item) Made of Incoloy 825 Heat input 3.0 to 9.0kW Including temperature control and overheating protection Not suitable for continuous electrical heating Delivered separately packed On site Installation and wiring of the optional electrical immersion heater by others Buffer storage vessel with insulation and foil casing completely fitted and packed
4 Part No. Buffer storage vessels EnerVal ( ) EnerVal ( ) completely insulated, steel vessel. Bare finish internally, exterior with coloured plastic coating Nominal EnerVal content Ø raw Ø insulated Height type l mm mm mm (200) (300) (500) (800) (1000) (1500) (2000) Accessories Connection hose with T-piece for EnerVal (800,1000) for the hydraulic parallel connection of two energy buffer storage vessels EnerVal Consisting of: flexible hose included insulation and a T-piece 1½ Connection hose with T-piece for EnerVal (1500, 2000) for the hydraulic parallel connection of two energy buffer storage vessels EnerVal Consisting of: flexible hose included insulation with a T-piece 2 Connection hose for EnerVal (800,1000) for the hydraulic parallel connection of two energy buffer storage vessels EnerVal Consisting of: flexible hose included insulation 1½ Connection hose for EnerVal (1500, 2000) for the hydraulic parallel connection of two energy buffer storage vessels EnerVal Consisting of: flexible hose included insulation Screw-in injection sparge pipe For horizontal installation in the energy buffer storage vessel. For the decrease of turbulence of the water within the EnerVal. Type Screw-in depth [mm] For EnerVal type Rp 1½ , Rp ,
5 Part No. Accessories Double thermostat ATH-22 Suitable for low temperature thermostat to start the loading pump. Suitable for high temperature thermostat to limit the flow. Bottom part of the casing made of die-cast aluminium with plastic cover, with rigid shaft 1 separate temperature adjustment each in the casing Type of protection IP54 Switching capacity: 230V/10A cos=1 Control range 1.2 : 0 C +100 C Switching differential 1.2 : 3-4% of the scale range Sensor pocket: G 1/2,L=150mm, D=15mm Sensor pocket brass nickel-plated Version according to DIN EN Immersion thermostat RAK-TW1000.S SB 150 Thermostat with sensor pocket ½ - depth of probe 150mm, brass nickel-plated Thermometer type TMOV including sensor pocket ½ C Protective sensor pocket SB150 ½ brass nickel-plated PN10-150mm Protective sensor pocket SB280 ½ brass nickel-plated PN10-280mm Screw-in electrical immersion heater Immersion heater made of Incoloy alloy 825, with temperature control and overheating protection. Delivered separately, installation and wiring on site by others. For Output Voltage Installation EnerVal Type kw V mm type EP x ( ) EP x ( ) EP-4, x ( ) EP x ( )
6 Technical data EnerVal ( ) Type (200) (300) (500) (800) (1000) (1500 (2000) Nominal content litres Working pressure/test pressure bar 3/4 3/4 3/4 3/4 3/4 3/4 3/4 Working temperature maximum C Thermal insulation PU soft foam mm Thermal conductance λ W/mK Standing loss qb at 60 C W Weight with insulation (dry) kg Weight without insulation (dry) kg Dimensions see table of dimensions Screw-in electrical immersion heater Immersion heater made of Incoloy alloy 825 with temperature control and overheating protection, connection. Not suitable for continuous electrical heating. Type Output Voltage Installation depth For EnerVal kw [V] mm Type EP-2 2,0 1 x ( ) EP-3 3,0 3 x ( ) EP-4,5 4,5 3 x ( ) EP-6 6,0 3 x ( ) EP-9 9,0 3 x ( )
7 Dimensions (Dimensions in mm) EnerVal (200,300) EnerVal (500) 1 Heating connection Rp 1½ 2 Connection for screw-in electrical immersion heater Rp 1½ (positioning depending on the schematic) 3 Sensor pocket, thermostat or thermometer Rp ½ 4 Cable trunking 5 only EnerVal (300) Length of all sockets: 50mm Possible variance because of production tolerance Dimension +/- 10mm EnerVal type L1 L2 a b c d D e f g h j k l m (200) (300) (500)
8 Dimensions EnerVal ( ) (Dimensions in mm) 1 Heating connection type (800,1000) Rp 1½ type (1500,2000) Rp 2 2 Sleeve for electric immersion heater boiler socket Rp 1½ 3 Sensor pocket, thermostat or thermometer Rp ½ Length of all sockets: 120mm Possible variance because of production tolerance Dimension +/- 10mm EnerVal type a b c c1 d D e f g h j k l m n (800) (1000) (1500) (2000)
9 Dimensions Connection set for EnerVal thermal storage vessels (Dimensions in mm) Connection of 2 EnerVal ( ) EnerVal type A B D D1 R (500) ( ) Connection of 2 EnerVal ( ) EnerVal type A B D D1 R Q (1500) (2000) Illustration: connection of 2 EnerVal thermal storage vessels with connection set Flow from boiler Flow to heating Flow from boiler Flow to heating EnerVal thermal storage vessel EnerVal thermal storage vessel
10 Description Buffer storage vessel EnerVal G (1000) Steel buffer storage vessel for the hydraulic integration with heating boilers, heat pumps and solar energy systems 8 connection nozzles 3 OT 3 connections Rp 2 2 connections Rp ½ for sensor/thermometer 2 sensor channels ¼ - Ø 17.2mm x Ø 13.2mm With detachable polyurethane soft foam thermal insulation, insulation thickness: 120mm Plastic outer shell with integrated zipper, colour red Fully insulated buffer storage vessel Buffer storage vessel EnerVal G (1500,2500) Steel buffer storage vessel for the hydraulic integration of heating boilers, solid fuel boilers, CHP plants, heat pumps and solar energy systems 10 connection nozzles 3 OT 4 sleeves Rp ½ for sensor / thermometer With detachable polyurethane soft foam thermal insulation, insulation thickness: 120mm Plastic outer shell with integrated zipper, colour red Fully insulated buffer storage vessel (1500) Buffer storage vessel (2500), thermal insulation supplied separately for fitting by the installer Buffer storage vessel EnerVal G (4000) Steel buffer storage vessel for the hydraulic integration of heating boilers, solid fuel boilers, CHP plants, heat pumps and solar energy systems 10 connection nozzles 3 OT 4 sleeves Rp ½ for sensor / thermometer Buffer storage vessel, packed, without thermal insulation Thermal insulation to be provided on site by others Buffer storage vessel EnerVal G (6000) Steel buffer storage vessel for the hydraulic integration of heating boilers, solid fuel boilers, CHP plants, heat pumps and solar energy systems 10 connection flanges DN sleeves Rp ½ for sensor / thermometer Buffer storage vessel, packed, without thermal insulation Thermal insulation to be provided on site by others Series EnerVal G type Nominal content l (1000) 904 (1500) 1420 (2500) 2361 (4000) 4021 (6000) 5897 (8000) 8000 (10000) Buffer storage vessel EnerVal G (8000) Steel buffer storage vessel for the hydraulic integration of heating boilers, solid fuel boilers, CHP plants, heat pumps and solar energy systems 4 connection flanges DN sleeves Rp ½ for sensor / thermometer Buffer storage vessel, packed, without thermal insulation Thermal insulation to be provided on site by others Buffer storage vessel EnerVal G (10000) Steel buffer storage vessel for the hydraulic integration of heating boilers, solid fuel boilers, CHP plants, heat pumps and solar energy systems 4 connection flanges DN sleeves Rp ½ for sensor / thermometer Buffer storage vessel, packed, without thermal insulation Thermal insulation to be provided on site by others Thermal insulation for buffer storage vessel EnerVal G ( ) Made from polyurethane soft foam With foil casing, colour red Thermal insulation in separate packaging (2500) Fully insulated buffer storage vessel (1000,1500), packaged On site Fitting of the thermal insulation by the installer
11 Part No. Buffer storage vessel EnerVal G ( ) EnerVal G (1000,1500) fully insulated; EnerVal G (2500), thermal insulation supplied separate for fitting by the installer; EnerVal G ( ) supplied without thermal insulation. Thermal insulation to be provided on site by others; steel vessel un-coated internally. EnerVal G Nom. content Ø uninsulated Ø insulated Height type l mm mm mm (1000) (1500) (2500) (4000) (6000) (8000) (10000) Thermal insulation Made from polyurethane soft foam with foil casing, colour red. Delivered separately packed, for fitting by the installer. EnerVal G type (2500) 120 Insulation thickness mm Accessories Protective pipe immersion sleeve SB150 ½ brass nickel-plated PN10-150mm Protective pipe immersion sleeve SB280 ½ brass nickel-plated PN10-280mm Immersion thermostat RAK-TW1000.S SB C, setting (externally visible) under the casing cover. Including immersion sleeve ½ - immersion depth 150mm, made from nickel-plated brass. Thermometer type TMOV including immersion sleeve ½ C
12 Technical data EnerVal G ( ) Type (1000) (1500) (2500) (4000) (6000) Nominal content l Operating/test pressure bar 3/4 3/4 3/4 3/4 3/4 Maximum operating temperature C Thermal insulation PU soft foam mm Thermal conductance λ W/mK Standby losses qb at 60 C W Weight without insulation (dry) kg Dimensions EnerVal G ( ) Type (8000) (10000) Nominal content l Operating/test pressure bar 3/4 3/4 Maximum operating temperature C Thermal insulation PU soft foam mm - - Thermal conductance λ W/mK - - Standby losses qb at 60 C W - - Weight without insulation (dry) kg Dimensions see dimensional drawing see dimensional drawing
13 Dimensions (Dimensions in mm) EnerVal G (1000) EnerVal G (1500,2500) 1 Heating connection ( ): R 3 (OT), nozzle length: 140mm 2 Sensor pocket, thermostat or thermometer Rp ½ 3 Connection nozzle Rp 2 4 Sensor channel ¼ 5 Perforated plate Possible variance because of production tolerance Dimension +/- 10mm EnerVal G type a b c d D e f g h k m L1 L2 (1000) (1500) (2500)
14 Dimensions (Dimensions in mm) EnerVal G (4000) EnerVal G (6000) 1 Heating connection (4000): R 3 (OT), nozzle length: 200mm (6000): prewelded flange DN 100 PN 6 flange, nozzle length: 200mm 2 Sensor pocket, thermostat or thermometer Rp ½ Possible variance because of production tolerance Dimension +/- 10mm EnerVal G type a b c d e f g h k m (4000) (6000)
15 Dimensions EnerVal G (8000) (Dimensions in mm) 1 Heating connection DN 150 / PN 16 2 Air vent socket Rp 1½ 3 Sensor pocket, thermostat or thermometer Rp ½ 4 Removable inspection flange DN 250 / PN 6 5 Drain connection Rp 1½ Possible variance because of production tolerance Dimension +/- 10mm EnerVal 8000 a b c c1 d D e h j k l m n o p q (8000) r s t u v
16 Dimensions EnerVal G (10000) (Dimensions in mm) 1 Heating connection DN 150 / PN 16 2 Air vent socket Rp 2 3 Sensor pocket, thermostat or thermometer Rp ½ 4 Removable inspection flange DN 250 / PN 6 5 Drain connection Rp 2 Possible variance because of production tolerance Dimension +/- 10mm EnerVal a b c d D h j k l m n o p q r s (10000) t u v
17 Notes
18 An expert partner One-stop shopping With us you can easily incorporate gas, oil, heat pump, solar, CHP, or biomass energy solutions into your heating system. Technical advice We are happy to assist you and your planning partners in developing intelligent systems, allowing you to take advantage of our expertise and the experience of our specialists. After sales For specialist commissioning and maintenance of your Hoval equipment, contact our service and spares department. Hoval Ltd Northgate Newark-on-Trent Nottinghamshire NG24 1JN United Kingdom Phone Fax /15 Responsibilty for energy and environment Hoval follows a policy of continued improvement and reserves the right to change specifications without notice.
Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps
Airfix D-E 6442.eps GB Installation and operating instructions 1999, Exclusion of liability All operation and maintenance related technical information, data and instructions contained in these installation
More informationbetter measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis
More information50Hz. water solutions. O SerieS DGO DRO
Hz water solutions O SerieS DGO DRO D a t a b o o k l e t EN water solutions O SerieS DGO DRO Hz D a t a b o o k l e t O SERIES O Series General characteristics AISI stainless steel lifting and carrying
More informationPressVal Pressurisation Units. Packaged Pressurisation Units with expansion vessels for heating systems.
PressVal Packaged with expansion s for heating systems. lamco Basepak LEXILLER lamco Basepak LEXILLER POWER AULT MUTE/ RESET SYSTEM OK lamco ON / O lamco Basepak LEXILLER PressVal SM skid mounted units
More informationMonitoring device NTS 30
P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit
More informationTechnical Data Sheet T 2025
Self-operated emperature Regulators emperature Regulator ype 4 Valve closes when the temperature rises. emperature Regulator ype 4u Valve opens when the temperature rises. Balanced single-seated globe
More informationTwo-port valves, male threaded, PN25
4 379 Two-port valves, male threaded, PN25 VVG55... Two-port valves, externally threaded, PN25 Bronze Rg5 DN15... 25 mm (½"... 1") k vs 0.25... 6.3 m 3 /h Stroke 5.5 mm Suitable for type SQS35... or SQS65...
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationV5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet
V5001P Kombi-Auto Differential Pressure Control Valve Product specification sheet Content Application...1 Special Features...1 Valve Efficiency...1 Technical Data...2 Construction...2 Materials...2 Method
More informationFlamco Flamco-Fill STA Flamco-Fill STM
STA STM Typ STA 5936 Typ STM 5937 GB Installation and operating instructions 1999, 2 Contents GB UK Limited P.O. Box 9, Washway Lane, St. Helens, Merseyside WA10 6FE United Kingdom Telephone: 01744 744744
More informationVERTICAL BLADDER TANK
Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure
More informationSIHI LPH-X - Liquid Ring Compressors
- Liquid Ring Compressors LPH 50523 LPH 60527 Pressure range: Suction volume range: 0.2 to 1.5 bar 260 to 780 m³/h CONSTRUCTION Sterling SIHI liquid ring compressors are displacement compressors with a
More informationBlowdown vessels Meeting the requirements of HSE PM60
Blowdown vessels Meeting the requirements of HSE PM60 BDV60 blowdown vessels A complete range of equipment for the safe disposal of boiler blowdown Boiler blowdown Steam boilers must be blown down to remove
More informationRadiator valves VDN1.. VEN1..
2 105 EN 215 Straight valves VDN1.. Angle valves VEN1.. ACVATIX TM Radiator valves VDN1.. VEN1.. DIN-norm, for 2-pipe heating systems Valve bodies made of brass, mat nickel-plated DN 10, DN 15 and DN 20
More informationHORIZONTAL BLADDER TANK
Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure
More informationHDPE. Dredging Pipeline
HDPE Dredging Pipeline R Ace Flowtech Co., Ltd Office address: No.2, 2-1601, Rongyuan Road, Huayuan Industrial Park, Tianjin Binhai Hi- Tech Area, Tianjin City, China, 300384 Factory address: No.51 Lutai
More informationRemeha Quinta Cascade guide
Technical information Remeha Quinta Cascade guide Cascade guide Cascade systems 2 Remeha Quinta Cascade guide TABLE OF CONTENTS FOREWORD 4 1 GENERAL DESCRIPTION OF CASCADE SYSTEMS 4 1.1 Optimum number
More informationWORCESTER GREENSTORE. Indirect Unvented Cylinder with Solar Coil FOR USE WITH WORCESTER GREENSTORE SYSTEM HEATPUMP ONLY GB/IE
WORCESTER GREENSTORE Indirect Unvented Cylinder with Solar Coil FOR USE WITH WORCESTER GREENSTORE SYSTEM HEATPUMP ONLY GB/IE WORCESTER GREENSTORE 180 CYLINDER SOLAR COMPATIBLE WORCESTER GREENSTORE 280
More informationFeatures. Up to 6 switch points Minimum degree of protection IP65 Optional temperature sensor PT1000 or thermostat Potted electrical contacts
FLOAT LEVEL SWITCH The label Trafag Industrial Components extends the Trafag brand name to instruments manufactured by qualified partner companies. Trafag Industrial Components complement the genuine Trafag
More informationMounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6
Series 43 Temperature Regulators Type 43-5 and Type 43-7 Type 43-6 Type 43-6 Type 43-7 with flanged valve body, DN 32 to 50 Type 43-5 Type 43-7 with welding ends Mounting and Operating Instructions EB
More informationMass Flow Meter (MFM) for Gases
873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital
More informationFlat roof drainage 1
Flat roof drainage 1 F Ü R D I E ZU K U N FT G E DAC HT. alwitra waterproofing system Flat roof drainage systems are part of the proven alwitra waterproofing system. This system comprises: 1 Waterproofing
More informationUNVENTED HOT WATER SYSTEMS HAVE BECOME EXTREMELY POPULAR FOR BUILDING APPLICATIONS. WITH ALL THE MANDATORY
Unvented Packages Contents UNVENTED HOT WATER SYSTEMS 1 SYSTEM SCHEMATICS 2 PACKAGED EQUIPMENT 3 UNVENTED PACKAGES 4 DESIGNING UNVENTED SYSTEMS 5-7 CONVERSION FACTORS 8 EXPANSION VESSEL SELECTION TABLES
More information2-Port Seat Valves with Flange, PN 16
4 40 2-Port Seat Valves with Flange, PN 6 VVF4... Grey cast iron EN-GJL-250 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SQX- electromotoric or SKD...-, SKB...- or SKC...- electrohydraulic
More informationWater Safety Shut-off Valve HON 790
Water Safety Shut-off Valve HON 790 790.20 OPERATING AND MAINTENANCE INSTRUCTIONS/ SPARE PARTS EDITION 01/2017 Serving the Gas Industry Worldwide Contents Page 1. General information 3 1.1 Safety information
More informationLMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.
LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mho up to 0... 50 mho Output signals -wire: 4... 0 ma -wire: 0...
More informationGENO -Flushing Compressor Product Data Sheet F 02
GENO -flushing compressor 1988 K Fig. 1: GENO -flushing compressor 1988 K Designated application is suitable for the following fields of application: Flushing of pipes with water/air mix prior to the start-up
More informationHot Water Stationary Unit
S 312 E-VA Hot Water Stationary Unit Technical Data S 312 E-VA (18 kw) Flow rate max. 620 l/h Unloading pressure 190 bar Working pressure max. 30-170 bar Water temperature max. 45 C Water inlet 3/4 Power
More informationSafety Shut-Off Valve HON 720
Safety Shut-Off Valve HON 70 Product information serving the gas industry worldwide Application, Characteristics, Technical Data Application main safety device for gas pressure regulating stations suitable
More informationInstallation, Operation and Maintenance Instructions Buffer Vessel OM006
Installation, Operation and Maintenance Instructions Buffer Vessel OM006 Calorifiers Heat Exchangers Pressurisation Units Sales Tel: 01457 835700 Sales Fax: 01457 832700 E-mail: sales@gmsthermal.co.uk
More information2-Port Seat Valves with Flange, PN 16
4 45 2-Port Seat Valves with Flange, PN 6 VVF45... dular cast iron EN-GJS-400-5 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SKB...- or SKC...- electrohydraulic actuators Use For use in
More informationExpansion Vessels for Potable Installations
4. Expansion Vessels for Potable Installations Domestic installations lose millions of litres of potable water due to expansion water leaking from the vent and expansion pipe. Flamco s Airfix diaphragm
More informationSLEEVED PLUG VALVES 2-WAY
Specialty Valves 2-WAY ANSI/ASME CLASS 150 LBS Dimensions to ANSI B16.5 & B16.10 1 Six (6) top holes * 2 1/2 valves are made from 3 casting, but flanges are machined to 2 1/2 dimensions 1/2 4.25 108.00
More informationSLEEVED PLUG VALVES 2-WAY
Specialty Valves 2-WAY ANSI/ASME CLASS 150 LBS Dimensions to ANSI B16.5 & B16.10 1 Six (6) top holes * 2 1/2 valves are made from 3 casting, but flanges are machined to 2 1/2 dimensions 1/2 4.25 108.00
More informationInstallation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger
OM008 Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger The operating and maintenance instructions contained within this package are for Pacific water/water
More informationMagnetic Level Gauges
Bulletin B 03 04 Magnetic Level Gauges Remote Reading Systems Magnetic Level Switches Magnetic level gauges OPERATING PRINCIPLE The operation of the magnetic level gauge is based on some elementary physical
More informationUCA-UVO-UCB. SUBMERSIBLE PUMPS Lifting of polluted water Commercial use 2 pole - 50 Hz OPERATING LIMITS APPLICATIONS CHARACTERISTICS ADVANTAGES
OPERATING LIMITS Flow rates up to: 24 m 3 /h Head up to: 62 m Maximum immersion depth: 12.5 m Max. particle size: Ø 5 to 8* ND discharge port: 8/1 mm IP : 68 *depending on model SUBMERSIBLE PUMPS Lifting
More information2-port seat valves PN25 with externally threaded connections
4 379 2-port seat valves PN25 with externally threaded connections VVG55.. Valve body bronze CC491K (Rg5) DN 15...25 (½...1 ") kvs 0.25...6.3 m3/h Stroke 5.5 mm Sets of ALG.. with threaded and ALS.. with
More informationInstallation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel
OM006 Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel The operating and maintenance instructions contained within this package are for standard mild steel buffer vessels
More informationPressure maintenance systems up to 10 MW with pumps
Pressure maintenance system with pumps Transfero T_ Pressure maintenance systems up to 10 MW with pumps Pressurisation & Water Quality alancing & Control Thermostatic Control ENGINEERING ADVANTAGE Pneumatex
More informationSpare parts list ( ) Spare parts list HDS 990
Spare parts list (5.952-855.0) Spare parts list HDS 990 13.10.2014 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list HDS 990 (5.952-855.0)... 6 10 Individual parts... 7 49 Spare
More informationRadiator valves VDN2.. VEN2.. VUN2..
2 106 EN 215 Straight valves VDN2.. Angle valves VEN2.. Reverse angle valves VUN2.. ACVATIX TM Radiator valves VDN2.. VEN2.. VUN2.. NF norm, for 2-pipe heating systems Valve bodies made of brass, mat nickel-plated
More informationTransfero TI. Pressure maintenence systems with pumps Pressure maintenance systems up to 40 MW with pumps
Transfero TI Pressure maintenence systems with pumps Pressure maintenance systems up to 40 MW with pumps IMI PNEUMATEX / Pressurisation / Transfero TI Transfero TI Transfero TI is a precision pressure
More informationBrewery Vessels. #Britishmade #Britishbeer
Brewery Vessels Custom Quality Equipment stainless steel for Quality vesselsbeer #Britishmade #Britishbeer Brewery Vessels 55 years experience in stainless steel product design and manufacture. Fabdec
More informationWE SAY: REFILL PLEASE!
multicontrol autofill MCA WE SAY: REFILL PLEASE! MULTICONTROL AUTOFILL SOLO MCA-S Ver.03/208-en OPERATING PRINCIPLE Operating principle Make-up Losses within the system are mostly unavoidable. To ensure
More informationMV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:
MV-01 2/2-way Solenoid Valve for Fluids Description: Features / Nominal diameters 1/4-2 / Pressure up to 10 bar / 24 V DC and all common AC variants / Forced-lifting The pilot-controlled full-way valve
More informationALUMINIUM TANK AND COMPENSATOR - SERIES 09
ALUMINIUM TANK AND Series 09 has been extended with the addition of an air/oil compensator. The Ø100 air/oil compensator consists of two aluminium flanges and an anodized jacket with an ISO profile, all
More informationTechnical Information Cleanfit CUA451
TI00369C/07/EN/13.13 71238305 Products Solutions Services Technical Information Cleanfit CUA451 Manually operated retractable assembly for water, wastewater and process media Application Drinking water
More informationInstallation and commissioning instructions 255 series and 256 series
Installation and commissioning instructions 255 series and 256 series Table of contents 1 General information... 3 1.1 About these instructions... 3 1.2 About this product... 3 1.3 Appropriate usage...
More informationsafety Shut-Off Valve HON 721
safety Shut-Off Valve HON 7 product information serving the gas industry worldwide safety shut-off valve HON 7 safety shut-off valve HON 7 Application, Characteristics, Technical Data Application safety
More informationRenewables. Tribune HE Unvented Hot Water Cylinders Installation and Maintenance Instructions. Issue 17 July 2012
Renewables Tribune HE Unvented Hot Water Cylinders Installation and Maintenance Instructions Issue 17 July 2012 IMPORTANT NOTE TO THE INSTALLER Read these instructions before commencing installation. Unvented
More informationSTAD Series. Balancing and control valves. Technical Data Sheet. WattsIndustries.com
STAD Series Balancing and control valves Technical Data Sheet WattsIndustries.com Description STAD Series variable-orifice threaded valves are designed for flow control and monitoring in climate control
More informationAirfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E
AIRFIX EXPANSION VESSELS Flamco Airfix Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX AIRFIX -E Flamco Edition 2005 / EXP Flamco Flamco offers you a wide choice
More informationPressure maintenance systems with compressors
Pressure maintenance systems with compressors Compresso Pressure maintenance systems with compressors Pressurisation & Water Quality alancing & Control Thermostatic Control ENGINEERING AVANTAGE Compresso
More informationArmatures for analytical probes
Armatures for analytical probes For many different types of installations and applications Large range of probe holders General purpose, water treatment, food & beverage, pharmaceutical applications Type
More informationASYBCO 90 O ELBOW LONG RADIUS O.D. I.D.
90 O ELBOW LONG RADIUS Standard weight Extra strong Schedule 160 Double extra strong ASTM A-234 ASME / ANSI B16.9 Carbon and ferritic alloy steel Produced from X-rayed, stress-relieve welded pipe. Welds
More informationFunction. size 1-¼ inch: 9-¾" size 1-½ inch: 11-¼" size 2 inch: 12-¾" A A A A A/96A A/99A
Hydro separator CLEI 0076/6 N CCREDITED Replaces 0076/4 N ISO 900 No. 000 ISO 900 M 2654 unction The Caleffi 548 and N hydraulic separator creates a zone with a low pressure loss, which enables connected
More informationElectronic Turbine Meter TERZ 94
Electronic Turbine Meter TERZ 9 PRODUT INFORMTION Reliable Measurements of Gas EETRONI TURINE METER TERZ 9 Methode of operation, construction 2 Methode of operation The TERZ 9 electronic turbine meter
More informationCALEFFI. Ball zone valves. series /03 GB
all zone valves series cert. n ISO / Function Zone valves are used to automatically shut-off the flow of carrier fluid distributed to a system. Specifically: -In central heating systems, they support the
More informationBOSS PULISCI PROVA IMPIANTI MEDIA
BOSS PULISCI PROVA IMPIANTI MEDIA Pump for power flushing operations and removal of impurities, suitable for hydraulic, solar, floor systems and for cooling circuits of medium size. Suitable for buildings,
More informationExpert Hydrostatic Level Transmitters
Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level
More informationInstruction Manual Contact Pressure Gauge
MS11 Instruction Manual Contact Pressure Gauge Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance 7.
More informationSeries 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28
Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) and balanced Type 2422 Valve Type 42-24 Type 42-28 Application Differential pressure regulators
More informationDifferential Pressure Control Valve. Passim
Differential Pressure Control Valve Passim 2 Table of contents Chapter Nexus Valve Passim DN 15-50, DN 65-80 1. Safety instructions 4 1.1 Rules/regulations 4 1.2 Intended use 5 1.3 Initial operation 5
More informationTANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR
SIT Group 836-837 TANDEM MULTIFUNCTIONAL GAS CONTROL MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR ALL ADJUSTMENTS ACCESSIBLE FROM ABOVE
More informationC-Flow Coriolis Mass Flow Meters
Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM
More informationInstallation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels
OM003 Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels The operating and maintenance instructions contained within this package are for standard storage vessels
More informationProcess Solutions. Electronic Turbine Meter TERZ 94 PROVEN TECHNOLOGY. SUPERIOR PERFORMANCE.
Process Solutions Electronic Turbine Meter TERZ 9 PROVEN TEHNOOGY. SUPERIOR PERFORMNE. Electronic Turbine Meter TERZ 9 Method of Operation The TERZ 9 electronic turbine meter is a flow meter which directly
More informationvacon nx ac drives hxl040 cooling unit, ss-piping commissioning and maintenance manual
vacon nx ac drives hxl040 cooling unit, ss-piping commissioning and maintenance manual WARNING HOT SURFACE! NOTE WARNING HOT SURFACE! NOTE 11571_uk WARNING ! NOTE! NOTE WARNING! NOTE Additional
More informationvacon nx ac drives hxm120 cooling unit, ss-piping commissioning and maintenance manual
vacon nx ac drives hxm120 cooling unit, ss-piping commissioning and maintenance manual WARNING HOT SURFACE! NOTE WARNING HOT SURFACE! NOTE 11571_uk WARNING ! NOTE! NOTE WARNING! NOTE Secondary
More informationRMG Meßtechnik GmbH. Publication No E
Electronic Turbine Meter TERZ 94 RMG Meßtechnik GmbH Publication No. 3.174-E P.O.ox 280 35502 utzbach (Germany) Tel.: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Internet: http://www.rmg.de
More informationFlamco Flexcon M-P Pump automat
Flexcon M-P Pump automat 0664 Flex MP-eps GB Installation and operating instructions 1999, Flamco 2 Installation and operating instructions Flexcon M-P pump automat Dear customer, GB With the purchase
More informationPneumatic spool valve islands
Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their
More informationModel MTB-ASME Vertical Bladder Tanks
DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationCALEFFI. Flow rate metering device. 683 series 01040/10 GB. Function
low rate metering device 683 series CCRI 040/ GB ISO 900 M 64 ISO 900 No. 0003 unction he flow rate metering device is used to measure the flow rate within a circuit. When used for central heating purposes,
More informationDatasheet IEC & ANSI Miniature or Standard Quick Wire Thermocouple Connector Plug & Socket Type K in IEC or ANSI Colour code
Datasheet IEC & ANSI Miniature or Standard Quick Wire Thermocouple Connector Plug & Socket Type K in IEC or ANSI Colour code ENGLISH These quick connect versions allow rapid termination Miniature connector
More informationTwo-port seat valves
4 345 Two-port seat valves with flange, PN16 VVF45... Two-port seat valves with flange, PN16 Spheroidal cast iron GGG-40 DN50...150 mm k vs 19...300 m 3 /h Stroke 20 or 40 mm Can be equipped with actuators
More informationModel MTB-ASME Vertical Bladder Tanks
DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationMechanical Pressure Measurement
Mechanical Pressure Measurement Differential Pressure Gauges Model GDP, Universal Version, with Diaphragm Element High Overpressure Safety PN 40, 100, 250 or 400 Applications Differential pressure measurement
More informationThree-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils
4 440 Three-port valves with flange, PN6 VXF4... Three-port valves with flange, PN6 Can be used as mixing or diverting valves Grey cast iron GG-25 DN5...50 mm k vs.9...300 m 3 /h Stroke 20 or 40 mm Can
More informationGas Pressure Regulator HON 502
Gas Pressure Regulator HON 502 Product information serving the gas industry worldwide Gas Pressure regulator HON 502 Application, Characteristics, Technical Data Application for offtake stations in gas
More informationvalves Total Control.
valves Total Control. Contents Tempering Valves 2 Thermostatic Mixing Valves 4 Non-Return Isolating Valves 5 Pressure Reducing Valves 6 Pressure Limiting Valves 8 ackflow Prevention Valves 9 Pressure
More informationTechnical Datasheet. Rigid & Retractable Pendants. Rigid Pendant
Rigid & Retractable Pendants Rigid Pendant Description Rigid pendants are intended for use operating theatres, anaesthetic rooms and similar medical locations. They are an ergonomic solution for the provision
More informationBallorex Dynamic Description. Versions. Benefits. Balancing
Ballorex Dynamic Description The Ballorex Dynamic valve is a combined pressure independent flow limiter and control valve which maintains a constant flow independently of pressure changes in heating or
More informationLess power great performances
148 SMART SMART Less power great performances SMART is the answer to the increasing demand for both low energy consumption and high efficiency. Based on many years experience in road lighting, it offers
More informationBall valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany
Ball valve HKSF-W100 RMA Kehl GmbH & Co. KG Oststrasse 17 D-77694 Kehl / Germany info@rma-kehl.de www.rma-armaturen.de 1 Design Features: RMA-ball valves type HKSF-W are fully welded and completely maintenance-free
More informationTA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics
TA-FUSION-P Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics IMI TA / Control valves / TA-FUSION-P TA-FUSION-P These innovative
More informationGas Pressure Regulator HON 300
Product information serving the gas industry worldwide Applications, characteristics, technical data Applications direct acting gas pressure regulator, for systems in accordance with DVGW working instruction
More informationENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code)
ENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code) Miniature size in-line Thermocouple Socket with stainless
More informationProduct information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983
Product information Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69 Document ID: 29983 Contents Contents 1 Description of the measuring principle... 3 2 Type overview...
More information2-port and 3-port valves PN 16
OEM 2-port valves VVP459.10-0.63 to VVP459.25-6.3 3-port valves VXP459.10-0.63 to VXP459.25-6.3 3-port valves with bypass VMP459.10-0.63 to VMP459.20-4 2-port valves VVP459.25-6.3 to VVP459.40-25 3-port
More informationAutomatic balancing valves ASV
Automatic balancing valves ASV ASV-P ASV-PV ASV-PV ASV-PV ASV-I ASV-M 15-40 15-40 50 65-100 15-50 15-50 Description / Application ASV balancing valves are used for dynamic hydronic balance in heating and
More informationHorizontal Bladder Tanks
DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationV5434T/H THREE-WAY ROTARY VALVE PN10 AND H-EXTENSION
V544T/H THREE-WAY ROTARY VALVE PN10 AND H-EXTENSION FEATURES PRODUCT DATA Chrome-plated plug for long life-span Optimized characteristics for supply water temperature control All around changeable rotary
More informationVertical Bladder Tanks
DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationAutomatic balancing valves ASV
Automatic balancing valves ASV ASV-PV ASV-PV ASV-PV ASV-BD ASV-M DN 15-40 DN 50 DN 65-100 DN 15-50 DN 15-50 Description / Application ASV balancing valves are used for dynamic hydronic balance in heating
More informationAutomatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN
Data sheet Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN 40-100 Description AB-PM is ideal for staged installation and commissioning AB-PM is a combined
More informationDifferential pressure
Differential pressure 9 Overview Page 200 VEGADIF 65 Page 202 Chemical seal Page 204 Accessory Page 208 199 VEGADIF For differential pressure, level and flow measurements Measuring principle The sensor
More informationAdditional sheet to leaflet Pressure regulators with safety assemblies, Print No Inlet pressures up to max. 1 bar Page 2
Weishaupt Pressure regulators with safety assemblies for - Inlet pressures up to max. 1 bar - Inlet pressures greater than 4 bar - Outlet pressures 180 to 350 mbar Additional sheet to leaflet Pressure
More information