ERF. Models ERF 01 ERF 02 ERF 03 ERF 04. Models ERF 01 R ERF 02 R ERF 03 R ERF 04 R

Size: px
Start display at page:

Download "ERF. Models ERF 01 ERF 02 ERF 03 ERF 04. Models ERF 01 R ERF 02 R ERF 03 R ERF 04 R"

Transcription

1

2

3 For refrigerating cabinets,and small cold rooms, in high and low temperature applications. Casing and fan cover from recyclabe ABS, without sharp or cutting edges. ERF Easy removable casing with plastic clips, to facilitate installation and maintenance Finned coils from corrugated aluminum fins with 4mm spacing and cooper tubes 3/8". On demand coils with anticorrosion treatment, certified for use in a food area. Nominal Capacity R404A (Watt) Models ERF 01 ERF 02 ERF 03 ERF 04 SC1 Δt=10K SC2 Δt=8K V/50 Hz 230V/50 Hz 230V/50 Hz 230V/50 Hz 1300 rpm 1300 rpm 1300 rpm 1300 rpm 1 x x x x 230 Power consumption Watt Air flow m 3 / h Air throw m 3,9 3,9 5,4 5,4 Defrost 230V Watt Ø Ø Ø Ø Exchange surface m² 2,40 2,50 4,20 4,30 Internal volume dm 3 0,44 0,60 0,76 1 Inlet 3/8" O.D. 3/8" O.D. 3/8" O.D. 3/8" O.D. Outlet 3/8" O.D. 3/8" O.D. 3/8" O.D. 3/8" O.D. Nominal Capacity R404A (Watt) Models ERF 01 R ERF 02 R ERF 03 R ERF 04 R SC3 Δt=7K SC4 Δt=6K V/50 Hz 230V/50 Hz 230V/50 Hz 230V/50 Hz 1300 rpm 1300 rpm 1300 rpm 1300 rpm 1 x x x x 230 Power consumption Watt Air flow m 3 / h Air throw m 4,0 4,0 5,5 5,5 Defrost 230V Watt Exchange surface m² 2,40 2,50 4,20 4,30 Internal volume dm 3 0,44 0,60 0,76 1 Inlet 3/8" O.D. 3/8" O.D. 3/8" O.D. 3/8" O.D. Outlet 3/8" O.D. 3/8" O.D. 3/8" O.D. 3/8" O.D. ER1017 2

4 ERF R 02R ERF R 04R Standard Conditions Standard Conditions Air Inlet Temperature C Evaporating Temperature C RH % SC SC SC SC Refrigerant Correction Factor Refrigerant R404A R134a R507A R407A R407C R407F SC1 1 0,93 0,97 1,19 1,21 1,19 SC2 1 0,91 0,97 1,24 1,26 1,24 SC3 1 0,85 0,97 1,28 1,31 1,29 SC4 1 0,97 1,32 1,36 1,35 Elvicon 4 Lefktron St Peristeri Athens Greece Tel : Fax: e mail : elvicon@elvicon.gr ER1017 3

5

6 For refrigerating cabinets,and small cold rooms, in high and low temperature applications. Casing and fan cover from recyclabe ABS, without sharp or cutting edges. DFE Fast installation without removing the plastic cover. Easy removable casing with 4 screws M4, for maintenance. Finned coils from corrugated aluminum fins with 4mm spacing and cooper tubes 3/8". On demand coils with anticorrosion treatment, certified for use in a food area. Nominal Capacity R404A (Watt) Models DFE DFE DFE DFE DFE DFE DFE SC1 Δt=10K SC2 Δt=8K V/50 Hz 230V/50 Hz 230V/50 Hz 230V/50 Hz 230V/50 Hz 230V/50 Hz 230V/50 Hz 1300 rpm 1300 rpm 1300 rpm 1300 rpm 1300 rpm 1300 rpm 1300 rpm 1 x x x x x x x 250 Power Input Watt Air flow m 3 / h Air throw m 2 x 3 2 x 3 2 x 2,8 2 x 4,3 2 x 4 2 x 6,4 2 x 5,5 Defrost 230V Watt Ø Ø Ø Ø Ø Ø Ø Exchange surface m² 3,5 3,6 4,5 8,2 10,3 12,3 18,6 Internal volume dm 3 0,51 0,85 1,02 1,8 2,44 2,7 4,4 Inlet 1/2" SAE 1/2" SAE 1/2" SAE 1/2" SAE 1/2" SAE 1/2" SAE 1/2" SAE Outlet 1/2" O.D. 1/2" O.D. 1/2" O.D. 18mm O.D. 18mm O.D. 18mm O.D. 18mm O.D. Nominal Capacity R404A (Watt) Models DFE DFE DFE DFE DFE DFE DFE 02 R 03 R 04 R 05 R 06 R 07 R 08 R SC3 Δt=7K SC4 Δt=6K V/50 Hz 230V/50 Hz 230V/50 Hz 230V/50 Hz 230V/50 Hz 230V/50 Hz 230V/50 Hz 1300 rpm 1300 rpm 1300 rpm 1300 rpm 1300 rpm 1300 rpm 1300 rpm 1 x x x x x x x 250 Power Input Watt Air flow m 3 / h Air throw m 2 x 3,1 2 x 3,1 2 x 2,8 2 x 4,5 2 x 4,1 2 x 6,6 2 x 5,7 Defrost 230V Watt Exchange surface m² 3,5 3,6 4,5 8,2 10,3 12,3 18,6 Internal volume dm 3 0,51 0,85 1,02 1,8 2,44 2,7 4,4 Inlet 1/2" SAE 1/2" SAE 1/2" SAE 1/2" SAE 1/2" SAE 1/2" SAE 1/2" SAE Outlet 1/2" O.D. 1/2" O.D. 1/2" O.D. 18mm O.D. 18mm O.D. 18mm O.D. 18mm O.D. DFE 02 DFE 03 DFE 04 DFE 05 DFE 06 DFE 07 DFE 08 Dimensions A mm B mm C mm D mm E mm F mm DF1017 2

7 Standard Conditions Standard Conditions Air Inlet Temperature C Evaporating Temperature C RH % SC SC SC SC Refrigerant Correction Factor Refrigerant R404A R134a R507Α R407Α R407C R407F SC1 1 0,93 0,97 1,19 1,21 1,19 SC2 1 0,91 0,97 1,24 1,26 1,24 SC3 1 0,85 0,97 1,28 1,31 1,29 SC4 1 0,97 1,32 1,36 1,35 Elvicon 4 Lefktron St Peristeri Athens Greece Tel : Fax: e mail : elvicon@elvicon.gr DF1017 3

8

9 Designed for Refrigerated Counters. For high temperature applications. White aluminium casing. cover and drain pan from ABS EBF Easy removable front casing, for easy cleaning and maintenance. Very fast installation. Finned coils from corrugated aluminum fins with 4mm spacing and cooper tubes 3/8", with anti corrosion treatment certified for use in a food area. Models EBF 01 EBF 02 EBF 11 EBF 12 Nominal Capacity SC1 Δt=10K R404A (Watt) SC2 Δt=8K V/1/50Hz 230V/1/50Hz 230V/1/50Hz 230V/1/50Hz 2400 rpm 2400 rpm 2700 rpm 2700 rpm 1 x Ø 60mm 1 x Ø 60mm 2 x Ø 120mm 2 x Ø 120mm Power consumption W A 0,37 0,37 0,26 0,26 Air flow m 3 / h Air throw m 5,7 5,7 2 x 2,2 2 x 2,2 Exchange surface m² 3,3 3,4 3,3 3,4 Internal volume dm 3 0,60 0,80 0,60 0,80 Inlet 3/8" O.D. 3/8" O.D. 3/8" O.D 3/8" O.D Outlet 3/8" O.D. 3/8" O.D. 3/8" O.D 3/8" O.D EBF 01 EBF 02 EBF 11 EBF 12 Standard Conditions Air Inlet Temperature C Evaporating Temperature C RH % SC SC Refrigerant R404A R134a R507A R407A R407F R407C SC1 1 0,93 0,97 1,19 1,21 SC2 1 0,91 0,97 1,24 1,26 Elvicon Standard Conditions Refrigerant Correction Factor 4Lefktron Str Peristeri, Athens Greece Tel : Fax: e mail : elvicon@elvicon.gr EB1017 2

10

11 Designed for patisseries display cases. Low air velocity for high temperature applications. Casing and fan cover from recyclabe ABS, without sharp or cutting edges. SLE Easy removable casing with 4 screws M4,to facilitate installation and maintenance. motor accesible by removing the plastic fan cover. Finned coils from corrugated aluminum fins with 4mm spacing and cooper tubes 3/8". On demand coils with anticorrosion treatment, certified for use in a food area. Models SLE 01 SLE 02 Nominal Capacity R404A (Watt) SC1 Δt=10K SC2 Δt=8K V/50 Ηz 230V/50 Ηz 1300 rpm 1300 rpm 1 x x 200 Power consumption Watt Air flow m 3 / h Air throw m 2 x 2,9 2 x 2,9 Exchange surface m² 3,9 4,0 Internal volume dm 3 0,62 0,83 Inlet 3/8" O.D. 3/8" O.D. Outlet 1/2" O.D. 1/2" O.D. Standard Conditions Standard Conditions Air Inlet Temperature C Evaporating Temperature C RH % SC SC Refrigerant Correction Factor Refrigerant R404A R134a R507A R407A R407F R407C SC1 1 0,93 0,97 1,19 1,21 SC2 1 0,91 0,97 1,24 1,26 Elvicon 4 Lefktron St Peristeri Athens Greece Tel : Fax: e mail : elvicon@elvicon.gr SL1017 2

Evaporator (DX) Freon Applications 1 12 Tons MHF

Evaporator (DX) Freon Applications 1 12 Tons MHF Evaporator (DX) Freon Applications 1 12 Tons > > Used For small to medium freon applications The Global Leader In Heat Exchange Technology With seven decades of experience and commitment to total client

More information

Crankcase pressure regulator, type KVL REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Crankcase pressure regulator, type KVL REFRIGERATION AND AIR CONDITIONING. Technical leaflet Crankcase pressure regulator, type KVL REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction.......................................................................................

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

LGR 7000XLi Dehumidifier

LGR 7000XLi Dehumidifier LGR 7000XLi Dehumidifier F412 Revision B Part# Part Description Qty Uom 02-01612 BLOWER ASSY - MOTORIZED IMPELLER 115V 200W 2775 RPM 1 EACH 02-01613 CABLE ASSY - JACKETED RJ45 7FT 1 EACH 02-01614 POWER

More information

market leading commercial and domestic ventilation with heat recovery Nilan VPM Active heat recovery and cooling (air/air)

market leading commercial and domestic ventilation with heat recovery Nilan VPM Active heat recovery and cooling (air/air) market leading commercial and domestic ventilation with heat recovery Nilan VPM 120-560 Active heat recovery and cooling (air/air) Nilan VPM 120-560 Industrial ventilation with heat recovery and cooling

More information

Solenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Solenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet Solenoid valves, two-step on/off PMLX REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3

More information

MAINLINE MLA14 AIR CONDITIONERS

MAINLINE MLA14 AIR CONDITIONERS FORM NO. AML-220 Supersedes Form No. PTZ-789 MAINLINE AIR CONDITIONERS Efficiencies up to 16 /13 Nominal Sizes 1.5-5 Ton [5.28 TO 17.6 KW] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured

More information

NLE10CN V/50Hz 1~

NLE10CN V/50Hz 1~ nle10cn_105h6175_r290_2v_50hz_06-18_ds.xlsx Sales code: 105H6175 NLE10CN 2-240V/50Hz 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 10,09cm³ / 0,62cu.in Oil quantity

More information

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No.

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No. FORM NO. AFJ-220 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*14C SERIES Efficiencies up to 16 S/13 Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7

More information

VRF. Technical Data Book. DVM S ECO for Europe (R410A, 50Hz, HP) Model : AM***KXMDGH/EU

VRF. Technical Data Book. DVM S ECO for Europe (R410A, 50Hz, HP) Model : AM***KXMDGH/EU VRF Technical Data Book DVM S ECO for Europe (R410A, Hz, HP) Model : AM***KXMDGH/EU History Version Modification Date Remark 1 Newly Release the TDB 15.12.15 Nomenclature Outdoor Units Model Names AM 080

More information

NLE11CNL V/60Hz 1~

NLE11CNL V/60Hz 1~ nle11cnl_105h5981_r290_115v_60hz_11-18_ds.xlsx Sales code: 105H5981 NLE11CNL 115-7V/60Hz 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 11,15cm³ / 0,68cu.in Oil quantity

More information

Part 1 General Information Part 2 Outdoor Units... 8

Part 1 General Information Part 2 Outdoor Units... 8 Contents Part 1 General Information... 1 Part 2 Outdoor Units... 8 Part 3 Installation... 71 Part 4 Part 5 Trouble shooting 99 Control system. 126 Manufacture reserves the right to discontinue, or change

More information

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet Overflow valves Type OFV 20-25 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction....................................................................................... 3 Features...........................................................................................

More information

DLE7.5CN V/50Hz 1~

DLE7.5CN V/50Hz 1~ dle75cn_102h4856_r290_2v_50hz_06-18_ds.xlsx Sales code: 102H4856 DLE7.5CN 2-240V/50Hz 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 7,48cm³ / 0,46cu.in Oil quantity

More information

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Displacement 12, , Maximum flow rate (at 1450 rpm) bar. 00/07 ED PVD VARIABLE DISPLACEMENT VANE PUMPS SERIES 0 OPERATING PRINCIPLE The PVD pumps are variable displacement vane pumps with a mechanical type of pressure compensator. They allow instantaneous adjustment

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION TECHNICAL DESCRIPTION Exhaust Hose Reel ser. 865, electric motor driven No. 981118101 Description Limit switches, for hose coiling and uncoiling integrated in drive unit. Motor turns drum via a planetary

More information

DLE5.7CN V/60Hz 1~

DLE5.7CN V/60Hz 1~ dle57cn_102h3682_r290_115v_60hz_06-18_ds.xlsx Sales code: 102H3682 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 5,7cm³ / 0,35cu.in Oil quantity 221cm³ / 7,5fl.oz

More information

DISPOSABLE GAS EQUIPMENT

DISPOSABLE GAS EQUIPMENT REGULATORS AND ACCESSORIES The disposable cylinders have different valving requirements to those cylinders that are designed to be refilled. As a result, there are dedicated regulators and other accessories

More information

DLE6.5CN V/60Hz 1~

DLE6.5CN V/60Hz 1~ dle65cn_102h3792_r290_115v_60hz_06-18_ds.xlsx Sales code: 102H3792 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 6,5cm³ / 0,4cu.in Oil quantity 221cm³ / 7,5fl.oz s

More information

Modulating liquid level regulators, direct-controlled, type SV 1 and 3 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Modulating liquid level regulators, direct-controlled, type SV 1 and 3 REFRIGERATION AND AIR CONDITIONING. Technical leaflet Modulating liquid level regulators, direct-controlled, type SV 1 and 3 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction...3 Technical data...3 Approvals...3 Identification...3

More information

Float valves Types SV 1 and SV 3

Float valves Types SV 1 and SV 3 Data sheet Float valves s SV 1 and SV 3 The SV 1 and 3 can be used separately as a modulating liquid level regulator in refrigerating, freezing and air conditioning systems for ammonia or fluorinated refrigerants.

More information

CHECK VALVES APPLICATIONS

CHECK VALVES APPLICATIONS 45 APPLICATIONS The check valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive 97//EC, Article 1, Section 2.1.4 and are subject of Article

More information

Model 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33.

Model 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33. EVAPORATOR COILS A COIL UNCASED R 22 or R 410A SYSTEMS 1 5 Tons WEAU Certification applies only when the complete system is listed with ARI ISO 9001:2000 REGISTERED R 410A R 22 Size Shipping Weight Size

More information

LindabSolus. Supply air beam. lindab we simplify construction

LindabSolus. Supply air beam. lindab we simplify construction lindab we simplify construction Lindab 03.2016 Lindab Ventilation. All forms of reproduction without written permission are forbidden. is the registered trademark of Lindab AB. Lindab's products, systems,

More information

AIR CONDITIONERS WA14**W SERIES

AIR CONDITIONERS WA14**W SERIES FORM NO. A66-225 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light

More information

Nordic Model CCM0330, 0430, 0530, 0630 Service Parts Manual (Includes 50Hz. Units)

Nordic Model CCM0330, 0430, 0530, 0630 Service Parts Manual (Includes 50Hz. Units) IMI CORNELIUS INC. www.cornelius.com Nordic Model CCM0330, 0430, 0530, 0630 Service Parts Manual (Includes 50Hz. Units) Publication Number: 631806058 Revision Date: October 13, 2009 Revision: E Visit the

More information

4HP15 PRODUCT SPECIFICATIONS 15 SEER SPLIT SYSTEM HEAT PUMP

4HP15 PRODUCT SPECIFICATIONS 15 SEER SPLIT SYSTEM HEAT PUMP 4HP15 PRODUCT SPECIFICATIONS 15 SPLIT SYSTEM HEAT PUMP FORM NO. 4HP15-100 (12/2017) FEATURES AND BENEFITS R410A Refrigerant High-quality condenser coil with copper tubing and enhanced louvered fin for

More information

Solenoid valve type EVR for Hydrocarbons

Solenoid valve type EVR for Hydrocarbons MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid valve type EVR for Hydrocarbons EVR for Hydrocarbons is a direct or servo operated solenoid valve especially designed for liquid, suction, and

More information

North American Orifice Metering System

North American Orifice Metering System Combustion North American Orifice Metering System 8697 and M8697 Metering Orifices accurately measure gas flows to industrial burners. They are compact, inexpensive, and can be installed in individual

More information

AIR CONDITIONERS WA14 SERIES

AIR CONDITIONERS WA14 SERIES FORM NO. A66-220 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light

More information

Shut-off valve Type QDV

Shut-off valve Type QDV Data sheet Shut-off valve Type QDV QDV is a shut-off valve, designed particularly for draining oil from systems containing refrigerant (ammonia) under pressure. The valve will close immediately on release

More information

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No.

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No. FORM NO. AFJ-222 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*16C SERIES Efficiencies up to 16 SEER/13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to

More information

Electric expansion valves Types AKV 10, AKV 15 and AKV 20

Electric expansion valves Types AKV 10, AKV 15 and AKV 20 Data sheet Electric expansion valves Types AKV 10, AKV 15 and AKV 20 AKV are electrically operated expansion valves designed for refrigerating plants. The AKV valves are normally controlled by a controller

More information

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz.

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz. SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz. Units ICE-O-Matic 11100 East 45th Ave Denver, Colorado 80239

More information

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8 and 1/4 PTF Port Sizes. Air line equipment. Air line equipment R Miniature Brass Body Regulator Water and Compressed Air Service 1/" and 1/" PTF Port Sizes Compact design, corrosion resistant construction Brass body with choice of plastic or brass

More information

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10 / ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications

More information

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Standard Operating and Maintenance Instructions for Pumping System Model PS-150 Standard Operating and Maintenance Instructions for Pumping System Model PS-150 High Pressure Equipment Company, LLC 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075

More information

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS GENERAL CHARACTERISTICS CONSTRUCTION FEATURES ENCLOSURE OPERATING TEMPERATURE 20 C/+60 C COVER Diecast aluminium (anodised) WEIGHT CSN 5 3.5 kg CSN 8 5 kg CSN

More information

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No.

AIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No. FORM NO. AFJ-221 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*13C SERIES Efficiencies 13-15.5 SEER/11.5-13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7

More information

Contents. Introduction Part 1 General Information Part 2 General Instruction Part 3 Outdoor Units Part 4 Installation...

Contents. Introduction Part 1 General Information Part 2 General Instruction Part 3 Outdoor Units Part 4 Installation... MHVAC-DTSM-2012-07 Contents Contents Introduction... 1 Part 1 General Information... 2 Part 2 General Instruction... 13 Part 3 Outdoor Units... 17 Part 4 Installation... 316 Part 5 Control System... 356

More information

Gas Pressure Regulator RMG 201

Gas Pressure Regulator RMG 201 Product information serving the gas industry worldwide Application, characteristics, technical data Application application in industrial stations for small flowrate regulating lines in gas pressure regulating

More information

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18 The Bray Simple Set Max is a flanged pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SSM Series combines high rangeability

More information

D A T A S H E E T. Technical Data. Maximum Working Gauge Pressure (bar) Capillary Tube Length (m) 1.5 (5Ft) Burst Gauge Pressure (bar) 234.

D A T A S H E E T. Technical Data. Maximum Working Gauge Pressure (bar) Capillary Tube Length (m) 1.5 (5Ft) Burst Gauge Pressure (bar) 234. TRAE Stretch series of Thermal Expansion Valves are designed predominantly for AC, heat pumps, close control, industrial process cooling applications, and transportation AC with HP demand. The new TRAE

More information

smartdraft TM Tap & One-way beer line Infosheet

smartdraft TM Tap & One-way beer line Infosheet smartdraft TM Tap & One-way beer line Infosheet smartdraft Tap & One-Way Beer Line Infosheet Dimensions: Tap: One-way beer line: Weight: Tap: One-way beer line: Pressure: Standard: Tolerance: Other on

More information

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80589-02 Table of Contents Components... 2 Test... 4 Recovery/Recycling... 5 Evacuation... 7 Charging...

More information

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz.

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz. SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz. Units Date 1/09 Table Of Contents This parts list contains

More information

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet Gas powered stop valves, type GPLX 80-150 REFRIGERATION AND AIR CONDITIONING Technical leaflet Technical leaflet Gas powered stop valves, type GPLX 80-150 Contents Page Introduction........................................................................................3

More information

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design Brueninghaus Hydromatik Series 1, for open circuits Axial piston - swashplate design, Back to back - design RE 93100/02.97 Sizes 60...260 Nominal Pressure up to 350 bar Peak Pressure up to 400 bar Preliminary

More information

UltraLo 1800 Alpha Particle Counter

UltraLo 1800 Alpha Particle Counter XIA LLC UltraLo 1800 Alpha Particle Counter Site Requirements & Planning Version: 0.4 Friday, February 15, 2013 Table of Contents I. Site Preparation Tasks... 3 A. Instrument Overview... 3 B. Installation

More information

Turbo Blowers. Combustion Excellence Since Features. Benefits

Turbo Blowers. Combustion Excellence Since Features. Benefits Turbo Blowers Features Integral molded scroll design Turbine bladed impeller Steel inlet guard Precisely balanced impellers eliminate vibration Complete line of available accessories for adapting to any

More information

Accessories for BHD Linear Drive Systems Series OSP-E..BHD

Accessories for BHD Linear Drive Systems Series OSP-E..BHD for BHD Linear Drive Systems Series -..BHD Contents Description Page nd Cap Mountings 36 Mid-Section Support 37 Adaptor Profile 38 T-Nut Profile 39 Motor Mountings Coupling Housing 40 Profile Mountings

More information

safety Shut-Off Valve HON 721

safety Shut-Off Valve HON 721 safety Shut-Off Valve HON 7 product information serving the gas industry worldwide safety shut-off valve HON 7 safety shut-off valve HON 7 Application, Characteristics, Technical Data Application safety

More information

Research of Variable Volume and Gas Injection DC Inverter Air Conditioning Compressor

Research of Variable Volume and Gas Injection DC Inverter Air Conditioning Compressor Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2016 Research of Variable Volume and Gas Inection DC Inverter Air Conditioning Compressor

More information

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100 Clean Air Filter Variations SFD SFD SFD SFD Made to Order Type Disposable (non-replaceable element) Cartridge (replaceable element) Flow rate L/min (ANR) (at inlet pressure.7 MPa) Up to 6 Up to 8 Up to

More information

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16 4 45 2-Port Seat Valves with Flange, PN 6 VVF45... dular cast iron EN-GJS-400-5 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SKB...- or SKC...- electrohydraulic actuators Use For use in

More information

Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING Technical leaflet Introduction QDV is a quick closing oil drain valve, designed particularly for draining oil from systems

More information

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities TECHNICAL SPECIFICATIONS FSH1BG Series FEATURES and BENEFITS Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities 1 The iq Drive heat pump system features modulating compressor

More information

Ducted Reverse Cycle Air Conditioning of Distinction

Ducted Reverse Cycle Air Conditioning of Distinction Ducted Reverse Cycle Air Conditioning of Distinction Transforming global energy-efficiency into an art form! The Braemar advantage Braemar ducted reverse cycle air conditioners are brought to you by Seeley

More information

Air Differentail Pressure Switch

Air Differentail Pressure Switch Page 1 of 5 PA-DPS-8x Air Differentail Pressure Switch Features: Benefits: Close switching differential Duct fixing kit included Switching point easily adjusted with scale in Pascals Conduit entry can

More information

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet Overflow valves Type OFV 20-25 Type OFV-SS 20-25 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction.......................................................................................

More information

BL68 - Olympian Plus, plug-in system Filter/regulators and lubricators

BL68 - Olympian Plus, plug-in system Filter/regulators and lubricators >> Port size: 3/4... /2 (ISO G/ PTF) >> Complete air processing units pre-assembled, ready to install Technical features Medium: Compressed air only Maximum operating pressure: 7 bar (246 psi) Pressure

More information

E SERIES. Specification. E Series. Relief and Flow Control Valves O M O M EIC-H Model No. Description

E SERIES. Specification. E Series. Relief and Flow Control Valves O M O M EIC-H Model No. Description 4 Ω-1 Ω Series Proportional Electro-ydraulic This relief and flow control valve is an energy-saving valve that supplies the minimum pressure and flow necessary for actuator drive. Since this valve controls

More information

Flow control valves Series RFU - RFO 2/

Flow control valves Series RFU - RFO 2/ CATALOGUE > Release 8.5 > Valves Series RFU - RFO Flow control valves Series RFU - RFO Unidirectional and bidirectional flow control valves Ports: M5, G1/8, G1/4, G3/8 and G1/ Nominal diameter: M5 = 1,5

More information

Liquid level regulating valves Types PMFL / PMFH and SV

Liquid level regulating valves Types PMFL / PMFH and SV Data sheet Liquid level regulating valves Types / PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant, a system comprising a liquid level regulating valve

More information

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings Installation Instructions V46 Issue Date 11//1 V46 Series -Way Pressure-Actuated Water-Regulating Valves With Union Fittings Application IMPORTANT: The V46 Series -Way Pressure-Actuated Water-Regulating

More information

Shut-off Liquid level and regulating valves for for Industrial Refrigeration

Shut-off Liquid level and regulating valves for for Industrial Refrigeration Catalogue Shut-off Liquid level and regulating valves for for Industrial Refrigeration Contents Page Float valve, type HFI... 3 Float valves, types SV 1 and 3... 17 Float valves, types SV 4, SV 5 and SV

More information

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50) Page 1 of 8 1. DESCRIPTION The Viking Model F-1 Deluge Valve is a quick opening, differential diaphragm, flood valve with one moving mechanism. The Deluge Valve is used to control water flow in Deluge

More information

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16 4 40 2-Port Seat Valves with Flange, PN 6 VVF4... Grey cast iron EN-GJL-250 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SQX- electromotoric or SKD...-, SKB...- or SKC...- electrohydraulic

More information

RTG 25. Introduction

RTG 25. Introduction Introduction RTG 25 pressure regulator is included within the direct acting and balanced valve regulator class. These regulators have a large range of applications both in industrial and domestic installations.

More information

Glass tube flowmeters Series 2000

Glass tube flowmeters Series 2000 Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases Short mounting length and compact construction, especially indicated for control panels Easy installation. No

More information

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in

More information

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids No contact with the product Compact design with polycarbonate housing (electronics and display).

More information

FMU4X, FMC4X FMU4P, FMC4P

FMU4X, FMC4X FMU4P, FMC4P ENVIRONMENTALLY SOUND REFRIGERANT FMU4X, FMC4X FMU4P, FMC4P Product Specifications HORIZONTAL FAN COILS FMU4P and FMC4P 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2 and 2 1/2 Tons ALL MODELS Horizontal

More information

TF- & DM-Series. Turbineflowmeter

TF- & DM-Series. Turbineflowmeter Turbineflowmeter .. are the ideal solution for measuring applications in liquids when high accuracy, very fast response times, compact design, high reliability are also required in continuous operation

More information

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE SIT Group SIT -3- SIGMA MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE 9.955. Subject to change without notice Application Domestic gas appliances: central heating boilers, combi boilers, instantaneous

More information

System Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner

System Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner System Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner Mohammad Khawaldeh Director, Unitary & Applied Product Units Presentation Outline Objectives Challenges Base

More information

Modulating liquid level regulators, servo-controlled PMFL / PMFH and SV

Modulating liquid level regulators, servo-controlled PMFL / PMFH and SV MAKING MODERN LIVING POSSIBLE Technical brochure Modulating liquid level regulators, servo-controlled / PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant,

More information

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings Installation Instructions V48 Issue Date 08/30/01 V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings Application IMPORTANT: The V48 Series 3-Way Pressure-Actuated Water-Regulating

More information

PORTABLE GAS FREEING FAN

PORTABLE GAS FREEING FAN PORTABLE GAS FREEING FAN TYPE MPV APPLICATIONS Typical application for this fan is mechanical ventilation of hazardous zones and cargo tanks onboard ships. To be mounted into tank openings on deck. DESIGN

More information

THE COMPACT LINE. Mobile power packs in convincing BAUER quality l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED

THE COMPACT LINE. Mobile power packs in convincing BAUER quality l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED THE COMPACT LINE Mobile power packs in convincing BAUER quality 100 140 l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED COMPACT LINE mobile breathing air compressors for high demands Due to its legendary

More information

Uniflair LE TDAR-TUAR

Uniflair LE TDAR-TUAR Uniflair LE TDAR-TUAR Direct Expansion air-cooled units with backward-curved fans 20-100kW > Perimeter cooling for medium/large data center > Refrigerant R-410A Available Versions: > Downflow (TDAR) >

More information

RMP/PSM WEBINAR SERIES

RMP/PSM WEBINAR SERIES RMP/PSM WEBINAR SERIES Webinar Starts at 08:00 PT Please call (877) 532-0806 if you are having technical issues. The background music may be used to adjust your audio volume. IIAR STANDARDS AND HOW THEY

More information

All technical data may be changed MADE IN ITALY BY NARDI COMPRESSORI

All technical data may be changed MADE IN ITALY BY NARDI COMPRESSORI PACIFIC MX NITROX BREATHING AIR according to DIN EN 12021 MAX OXYGEN 40% DELIVERY l/min 600 m 3 h 36 PRESSURE BAR 225 PSI 3250 Quality system certified to iso 9001 BREATHING AIR is a product line that

More information

Sales Office: Danfoss Expansion Valves. T*2 Range Order valve and orifice separately Range N -40 C to +10 C Without MOP

Sales Office: Danfoss Expansion Valves. T*2 Range Order valve and orifice separately Range N -40 C to +10 C Without MOP Danfoss Expansion Valves T*2 Range Order valve and orifice separately Range N -40 C to +10 C Without MOP Code Model Connections Danfoss No Internally Equalised F500 TX2 R22 3/8 x 1/2 flare 068Z3206 F502

More information

G SERIES METRIC MACHINE SCREW ACTUATOR

G SERIES METRIC MACHINE SCREW ACTUATOR G SERIES METRIC MACHINE SCREW ACTUATOR kn to 0kN Duff-Norton metric actuators are manufactured to the same high quality standards and include all the same features and benefits as the standard line of

More information

RobLight FL 1500 B-2. User manual. Applies to: RobLight A/S Nordhavnsvej 1A DK Frederikshavn. Phone:

RobLight FL 1500 B-2. User manual. Applies to: RobLight A/S Nordhavnsvej 1A DK Frederikshavn. Phone: 98082129 22-08-2018 Rev. 2.6 User manual FL 1500 B-2 A/S Nordhavnsvej 1A DK - 9900 Frederikshavn Applies to: + 0130 0058 FL 1500 B-2 3000K CRI 90+ + 0130 0068 FL 1500 B-2 4000K CRI 90+ + 0130 0658 FL 1500

More information

CO 2 radial piston compressor (transcritical)

CO 2 radial piston compressor (transcritical) CO 2 radial piston compressor (transcritical) At a glance Operating limits and performance data Technical data Dimensions and connections Scope of supply 124 126 129 130 131 Radial piston compressor (transcritical)

More information

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation Cryogenics Vacuum Dry Turbo Pumping Stations Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators Hermetically Sealed Pumps for He3 Recirculation Oils, Filters and Traps Valves, Fittings and Adaptors

More information

Measurement of Low GAS & Liquid Flows

Measurement of Low GAS & Liquid Flows Measurement of Low GAS & Liquid Flows The Measurement Measurement with a float in a tapered borosilicate glass tube. Series 2100 with a 100 mm flow tube Series 2150 with a 150 mm flow tube Series 2300

More information

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES PROCESS ANALYSERS DF-310E The DF-310E is a Coulometric sensor based oxygen analyzer designed to measure trace and percent level oxygen in pure and multi-gas backgrounds for process and quality control

More information

VERTICAL TURBINE PUMPS Right Angle Gears. Shaft Guarding for Horizontal Mounted Spicer Universal Joint Drive Shafts

VERTICAL TURBINE PUMPS Right Angle Gears. Shaft Guarding for Horizontal Mounted Spicer Universal Joint Drive Shafts Peerless Pump Company Indianapolis, IN 46207-7026 VERTICAL TURBINE PUMPS Right Angle Gears SECTION 110 Page 1 January 2, 2007 Shaft Guarding for Horizontal Mounted Spicer Universal Joint Drive Shafts A

More information

PVQ 13 A2 R SE 1 S 20 C-11 D

PVQ 13 A2 R SE 1 S 20 C-11 D PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard

More information

Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING. Technical leaflet Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction...3 Features...3 Technical data...4 Ordering...4 Sizing...5 Valve selection...5

More information

A soft sealed atmospheric safety valve with large flow capacity and soft seat tightness for steam condenser and turbine applications

A soft sealed atmospheric safety valve with large flow capacity and soft seat tightness for steam condenser and turbine applications SAPAG A soft sealed atmospheric safety valve with large flow capacity and soft seat tightness for steam condenser and turbine applications Features The Sapag Series 1100 steam safety valve is used for

More information

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN Important: Read all instructions and refer to local codes prior to installation. l Local soil conditions may require more gravel for drainage. l

More information

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Governor with solenoid valve Air/gas ratio control with solenoid valve VAG All-purpose servo-governor for gaseous media with integrated safety valve Suitable for a max. inlet pressure of 500 mbar Outlet

More information

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet Capacity regulator (hot gas bypass), type TUH/TCHE/ REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3

More information

GEAR PUMPS. Displacement from 5 to 39 ccm Pressure up to 280 bar Speed from 400 to 3000 RPM

GEAR PUMPS. Displacement from 5 to 39 ccm Pressure up to 280 bar Speed from 400 to 3000 RPM Displacement from 5 to 39 ccm Pressure up to 280 bar Speed from 400 to 3000 PM GEA PUMPS TABE OF CONTENTS DESCIPTION......................................................................................................................

More information

Coils Designed to Fit Your Requirements. Temtrol Manufacturing OEM & Replacement Coils Since 1955

Coils Designed to Fit Your Requirements. Temtrol Manufacturing OEM & Replacement Coils Since 1955 Temtrol Manufacturing OEM & Replacement Coils Since 1955 Coils Designed to Fit Your Requirements Chilled & Hot Water Direct Expansion Steam Distributing Condenser Standard Steam Quick Ship Program with

More information

Earlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System.

Earlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System. 17 1 Earlier Lecture In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System. Collins system is an extension of the Claude system to reach lower

More information