ERF. Models ERF 01 ERF 02 ERF 03 ERF 04. Models ERF 01 R ERF 02 R ERF 03 R ERF 04 R
|
|
- Brendan Miles
- 5 years ago
- Views:
Transcription
1
2
3 For refrigerating cabinets,and small cold rooms, in high and low temperature applications. Casing and fan cover from recyclabe ABS, without sharp or cutting edges. ERF Easy removable casing with plastic clips, to facilitate installation and maintenance Finned coils from corrugated aluminum fins with 4mm spacing and cooper tubes 3/8". On demand coils with anticorrosion treatment, certified for use in a food area. Nominal Capacity R404A (Watt) Models ERF 01 ERF 02 ERF 03 ERF 04 SC1 Δt=10K SC2 Δt=8K V/50 Hz 230V/50 Hz 230V/50 Hz 230V/50 Hz 1300 rpm 1300 rpm 1300 rpm 1300 rpm 1 x x x x 230 Power consumption Watt Air flow m 3 / h Air throw m 3,9 3,9 5,4 5,4 Defrost 230V Watt Ø Ø Ø Ø Exchange surface m² 2,40 2,50 4,20 4,30 Internal volume dm 3 0,44 0,60 0,76 1 Inlet 3/8" O.D. 3/8" O.D. 3/8" O.D. 3/8" O.D. Outlet 3/8" O.D. 3/8" O.D. 3/8" O.D. 3/8" O.D. Nominal Capacity R404A (Watt) Models ERF 01 R ERF 02 R ERF 03 R ERF 04 R SC3 Δt=7K SC4 Δt=6K V/50 Hz 230V/50 Hz 230V/50 Hz 230V/50 Hz 1300 rpm 1300 rpm 1300 rpm 1300 rpm 1 x x x x 230 Power consumption Watt Air flow m 3 / h Air throw m 4,0 4,0 5,5 5,5 Defrost 230V Watt Exchange surface m² 2,40 2,50 4,20 4,30 Internal volume dm 3 0,44 0,60 0,76 1 Inlet 3/8" O.D. 3/8" O.D. 3/8" O.D. 3/8" O.D. Outlet 3/8" O.D. 3/8" O.D. 3/8" O.D. 3/8" O.D. ER1017 2
4 ERF R 02R ERF R 04R Standard Conditions Standard Conditions Air Inlet Temperature C Evaporating Temperature C RH % SC SC SC SC Refrigerant Correction Factor Refrigerant R404A R134a R507A R407A R407C R407F SC1 1 0,93 0,97 1,19 1,21 1,19 SC2 1 0,91 0,97 1,24 1,26 1,24 SC3 1 0,85 0,97 1,28 1,31 1,29 SC4 1 0,97 1,32 1,36 1,35 Elvicon 4 Lefktron St Peristeri Athens Greece Tel : Fax: e mail : elvicon@elvicon.gr ER1017 3
5
6 For refrigerating cabinets,and small cold rooms, in high and low temperature applications. Casing and fan cover from recyclabe ABS, without sharp or cutting edges. DFE Fast installation without removing the plastic cover. Easy removable casing with 4 screws M4, for maintenance. Finned coils from corrugated aluminum fins with 4mm spacing and cooper tubes 3/8". On demand coils with anticorrosion treatment, certified for use in a food area. Nominal Capacity R404A (Watt) Models DFE DFE DFE DFE DFE DFE DFE SC1 Δt=10K SC2 Δt=8K V/50 Hz 230V/50 Hz 230V/50 Hz 230V/50 Hz 230V/50 Hz 230V/50 Hz 230V/50 Hz 1300 rpm 1300 rpm 1300 rpm 1300 rpm 1300 rpm 1300 rpm 1300 rpm 1 x x x x x x x 250 Power Input Watt Air flow m 3 / h Air throw m 2 x 3 2 x 3 2 x 2,8 2 x 4,3 2 x 4 2 x 6,4 2 x 5,5 Defrost 230V Watt Ø Ø Ø Ø Ø Ø Ø Exchange surface m² 3,5 3,6 4,5 8,2 10,3 12,3 18,6 Internal volume dm 3 0,51 0,85 1,02 1,8 2,44 2,7 4,4 Inlet 1/2" SAE 1/2" SAE 1/2" SAE 1/2" SAE 1/2" SAE 1/2" SAE 1/2" SAE Outlet 1/2" O.D. 1/2" O.D. 1/2" O.D. 18mm O.D. 18mm O.D. 18mm O.D. 18mm O.D. Nominal Capacity R404A (Watt) Models DFE DFE DFE DFE DFE DFE DFE 02 R 03 R 04 R 05 R 06 R 07 R 08 R SC3 Δt=7K SC4 Δt=6K V/50 Hz 230V/50 Hz 230V/50 Hz 230V/50 Hz 230V/50 Hz 230V/50 Hz 230V/50 Hz 1300 rpm 1300 rpm 1300 rpm 1300 rpm 1300 rpm 1300 rpm 1300 rpm 1 x x x x x x x 250 Power Input Watt Air flow m 3 / h Air throw m 2 x 3,1 2 x 3,1 2 x 2,8 2 x 4,5 2 x 4,1 2 x 6,6 2 x 5,7 Defrost 230V Watt Exchange surface m² 3,5 3,6 4,5 8,2 10,3 12,3 18,6 Internal volume dm 3 0,51 0,85 1,02 1,8 2,44 2,7 4,4 Inlet 1/2" SAE 1/2" SAE 1/2" SAE 1/2" SAE 1/2" SAE 1/2" SAE 1/2" SAE Outlet 1/2" O.D. 1/2" O.D. 1/2" O.D. 18mm O.D. 18mm O.D. 18mm O.D. 18mm O.D. DFE 02 DFE 03 DFE 04 DFE 05 DFE 06 DFE 07 DFE 08 Dimensions A mm B mm C mm D mm E mm F mm DF1017 2
7 Standard Conditions Standard Conditions Air Inlet Temperature C Evaporating Temperature C RH % SC SC SC SC Refrigerant Correction Factor Refrigerant R404A R134a R507Α R407Α R407C R407F SC1 1 0,93 0,97 1,19 1,21 1,19 SC2 1 0,91 0,97 1,24 1,26 1,24 SC3 1 0,85 0,97 1,28 1,31 1,29 SC4 1 0,97 1,32 1,36 1,35 Elvicon 4 Lefktron St Peristeri Athens Greece Tel : Fax: e mail : elvicon@elvicon.gr DF1017 3
8
9 Designed for Refrigerated Counters. For high temperature applications. White aluminium casing. cover and drain pan from ABS EBF Easy removable front casing, for easy cleaning and maintenance. Very fast installation. Finned coils from corrugated aluminum fins with 4mm spacing and cooper tubes 3/8", with anti corrosion treatment certified for use in a food area. Models EBF 01 EBF 02 EBF 11 EBF 12 Nominal Capacity SC1 Δt=10K R404A (Watt) SC2 Δt=8K V/1/50Hz 230V/1/50Hz 230V/1/50Hz 230V/1/50Hz 2400 rpm 2400 rpm 2700 rpm 2700 rpm 1 x Ø 60mm 1 x Ø 60mm 2 x Ø 120mm 2 x Ø 120mm Power consumption W A 0,37 0,37 0,26 0,26 Air flow m 3 / h Air throw m 5,7 5,7 2 x 2,2 2 x 2,2 Exchange surface m² 3,3 3,4 3,3 3,4 Internal volume dm 3 0,60 0,80 0,60 0,80 Inlet 3/8" O.D. 3/8" O.D. 3/8" O.D 3/8" O.D Outlet 3/8" O.D. 3/8" O.D. 3/8" O.D 3/8" O.D EBF 01 EBF 02 EBF 11 EBF 12 Standard Conditions Air Inlet Temperature C Evaporating Temperature C RH % SC SC Refrigerant R404A R134a R507A R407A R407F R407C SC1 1 0,93 0,97 1,19 1,21 SC2 1 0,91 0,97 1,24 1,26 Elvicon Standard Conditions Refrigerant Correction Factor 4Lefktron Str Peristeri, Athens Greece Tel : Fax: e mail : elvicon@elvicon.gr EB1017 2
10
11 Designed for patisseries display cases. Low air velocity for high temperature applications. Casing and fan cover from recyclabe ABS, without sharp or cutting edges. SLE Easy removable casing with 4 screws M4,to facilitate installation and maintenance. motor accesible by removing the plastic fan cover. Finned coils from corrugated aluminum fins with 4mm spacing and cooper tubes 3/8". On demand coils with anticorrosion treatment, certified for use in a food area. Models SLE 01 SLE 02 Nominal Capacity R404A (Watt) SC1 Δt=10K SC2 Δt=8K V/50 Ηz 230V/50 Ηz 1300 rpm 1300 rpm 1 x x 200 Power consumption Watt Air flow m 3 / h Air throw m 2 x 2,9 2 x 2,9 Exchange surface m² 3,9 4,0 Internal volume dm 3 0,62 0,83 Inlet 3/8" O.D. 3/8" O.D. Outlet 1/2" O.D. 1/2" O.D. Standard Conditions Standard Conditions Air Inlet Temperature C Evaporating Temperature C RH % SC SC Refrigerant Correction Factor Refrigerant R404A R134a R507A R407A R407F R407C SC1 1 0,93 0,97 1,19 1,21 SC2 1 0,91 0,97 1,24 1,26 Elvicon 4 Lefktron St Peristeri Athens Greece Tel : Fax: e mail : elvicon@elvicon.gr SL1017 2
Evaporator (DX) Freon Applications 1 12 Tons MHF
Evaporator (DX) Freon Applications 1 12 Tons > > Used For small to medium freon applications The Global Leader In Heat Exchange Technology With seven decades of experience and commitment to total client
More informationCrankcase pressure regulator, type KVL REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Crankcase pressure regulator, type KVL REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction.......................................................................................
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationLGR 7000XLi Dehumidifier
LGR 7000XLi Dehumidifier F412 Revision B Part# Part Description Qty Uom 02-01612 BLOWER ASSY - MOTORIZED IMPELLER 115V 200W 2775 RPM 1 EACH 02-01613 CABLE ASSY - JACKETED RJ45 7FT 1 EACH 02-01614 POWER
More informationmarket leading commercial and domestic ventilation with heat recovery Nilan VPM Active heat recovery and cooling (air/air)
market leading commercial and domestic ventilation with heat recovery Nilan VPM 120-560 Active heat recovery and cooling (air/air) Nilan VPM 120-560 Industrial ventilation with heat recovery and cooling
More informationSolenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Solenoid valves, two-step on/off PMLX REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3
More informationMAINLINE MLA14 AIR CONDITIONERS
FORM NO. AML-220 Supersedes Form No. PTZ-789 MAINLINE AIR CONDITIONERS Efficiencies up to 16 /13 Nominal Sizes 1.5-5 Ton [5.28 TO 17.6 KW] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured
More informationNLE10CN V/50Hz 1~
nle10cn_105h6175_r290_2v_50hz_06-18_ds.xlsx Sales code: 105H6175 NLE10CN 2-240V/50Hz 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 10,09cm³ / 0,62cu.in Oil quantity
More informationAIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No.
FORM NO. AFJ-220 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*14C SERIES Efficiencies up to 16 S/13 Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7
More informationVRF. Technical Data Book. DVM S ECO for Europe (R410A, 50Hz, HP) Model : AM***KXMDGH/EU
VRF Technical Data Book DVM S ECO for Europe (R410A, Hz, HP) Model : AM***KXMDGH/EU History Version Modification Date Remark 1 Newly Release the TDB 15.12.15 Nomenclature Outdoor Units Model Names AM 080
More informationNLE11CNL V/60Hz 1~
nle11cnl_105h5981_r290_115v_60hz_11-18_ds.xlsx Sales code: 105H5981 NLE11CNL 115-7V/60Hz 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 11,15cm³ / 0,68cu.in Oil quantity
More informationPart 1 General Information Part 2 Outdoor Units... 8
Contents Part 1 General Information... 1 Part 2 Outdoor Units... 8 Part 3 Installation... 71 Part 4 Part 5 Trouble shooting 99 Control system. 126 Manufacture reserves the right to discontinue, or change
More informationOverflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Overflow valves Type OFV 20-25 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction....................................................................................... 3 Features...........................................................................................
More informationDLE7.5CN V/50Hz 1~
dle75cn_102h4856_r290_2v_50hz_06-18_ds.xlsx Sales code: 102H4856 DLE7.5CN 2-240V/50Hz 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 7,48cm³ / 0,46cu.in Oil quantity
More informationDisplacement 12, , Maximum flow rate (at 1450 rpm) bar.
00/07 ED PVD VARIABLE DISPLACEMENT VANE PUMPS SERIES 0 OPERATING PRINCIPLE The PVD pumps are variable displacement vane pumps with a mechanical type of pressure compensator. They allow instantaneous adjustment
More informationTECHNICAL DESCRIPTION
TECHNICAL DESCRIPTION Exhaust Hose Reel ser. 865, electric motor driven No. 981118101 Description Limit switches, for hose coiling and uncoiling integrated in drive unit. Motor turns drum via a planetary
More informationDLE5.7CN V/60Hz 1~
dle57cn_102h3682_r290_115v_60hz_06-18_ds.xlsx Sales code: 102H3682 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 5,7cm³ / 0,35cu.in Oil quantity 221cm³ / 7,5fl.oz
More informationDISPOSABLE GAS EQUIPMENT
REGULATORS AND ACCESSORIES The disposable cylinders have different valving requirements to those cylinders that are designed to be refilled. As a result, there are dedicated regulators and other accessories
More informationDLE6.5CN V/60Hz 1~
dle65cn_102h3792_r290_115v_60hz_06-18_ds.xlsx Sales code: 102H3792 1~ design Oil type Polyolester Refrigerant(s) R290 Oil viscosity 32cSt Displacement 6,5cm³ / 0,4cu.in Oil quantity 221cm³ / 7,5fl.oz s
More informationModulating liquid level regulators, direct-controlled, type SV 1 and 3 REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Modulating liquid level regulators, direct-controlled, type SV 1 and 3 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction...3 Technical data...3 Approvals...3 Identification...3
More informationFloat valves Types SV 1 and SV 3
Data sheet Float valves s SV 1 and SV 3 The SV 1 and 3 can be used separately as a modulating liquid level regulator in refrigerating, freezing and air conditioning systems for ammonia or fluorinated refrigerants.
More informationCHECK VALVES APPLICATIONS
45 APPLICATIONS The check valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive 97//EC, Article 1, Section 2.1.4 and are subject of Article
More informationModel 26.5 WEAU242AA WEAU244BA 29.0 WEAU242BA 29.0 WEAU304AA 33.0 WEAU302AA WEAU304BA 33.0 WEAU302BA 33.
EVAPORATOR COILS A COIL UNCASED R 22 or R 410A SYSTEMS 1 5 Tons WEAU Certification applies only when the complete system is listed with ARI ISO 9001:2000 REGISTERED R 410A R 22 Size Shipping Weight Size
More informationLindabSolus. Supply air beam. lindab we simplify construction
lindab we simplify construction Lindab 03.2016 Lindab Ventilation. All forms of reproduction without written permission are forbidden. is the registered trademark of Lindab AB. Lindab's products, systems,
More informationAIR CONDITIONERS WA14**W SERIES
FORM NO. A66-225 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light
More informationNordic Model CCM0330, 0430, 0530, 0630 Service Parts Manual (Includes 50Hz. Units)
IMI CORNELIUS INC. www.cornelius.com Nordic Model CCM0330, 0430, 0530, 0630 Service Parts Manual (Includes 50Hz. Units) Publication Number: 631806058 Revision Date: October 13, 2009 Revision: E Visit the
More information4HP15 PRODUCT SPECIFICATIONS 15 SEER SPLIT SYSTEM HEAT PUMP
4HP15 PRODUCT SPECIFICATIONS 15 SPLIT SYSTEM HEAT PUMP FORM NO. 4HP15-100 (12/2017) FEATURES AND BENEFITS R410A Refrigerant High-quality condenser coil with copper tubing and enhanced louvered fin for
More informationSolenoid valve type EVR for Hydrocarbons
MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid valve type EVR for Hydrocarbons EVR for Hydrocarbons is a direct or servo operated solenoid valve especially designed for liquid, suction, and
More informationNorth American Orifice Metering System
Combustion North American Orifice Metering System 8697 and M8697 Metering Orifices accurately measure gas flows to industrial burners. They are compact, inexpensive, and can be installed in individual
More informationAIR CONDITIONERS WA14 SERIES
FORM NO. A66-220 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light
More informationShut-off valve Type QDV
Data sheet Shut-off valve Type QDV QDV is a shut-off valve, designed particularly for draining oil from systems containing refrigerant (ammonia) under pressure. The valve will close immediately on release
More informationAIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No.
FORM NO. AFJ-222 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*16C SERIES Efficiencies up to 16 SEER/13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to
More informationElectric expansion valves Types AKV 10, AKV 15 and AKV 20
Data sheet Electric expansion valves Types AKV 10, AKV 15 and AKV 20 AKV are electrically operated expansion valves designed for refrigerating plants. The AKV valves are normally controlled by a controller
More informationSERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz.
SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz. Units ICE-O-Matic 11100 East 45th Ave Denver, Colorado 80239
More informationALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.
Air line equipment R Miniature Brass Body Regulator Water and Compressed Air Service 1/" and 1/" PTF Port Sizes Compact design, corrosion resistant construction Brass body with choice of plastic or brass
More informationVPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10
/ ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications
More informationStandard Operating and Maintenance Instructions for Pumping System Model PS-150
Standard Operating and Maintenance Instructions for Pumping System Model PS-150 High Pressure Equipment Company, LLC 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075
More informationMECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET
CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS GENERAL CHARACTERISTICS CONSTRUCTION FEATURES ENCLOSURE OPERATING TEMPERATURE 20 C/+60 C COVER Diecast aluminium (anodised) WEIGHT CSN 5 3.5 kg CSN 8 5 kg CSN
More informationAIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No.
FORM NO. AFJ-221 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*13C SERIES Efficiencies 13-15.5 SEER/11.5-13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7
More informationContents. Introduction Part 1 General Information Part 2 General Instruction Part 3 Outdoor Units Part 4 Installation...
MHVAC-DTSM-2012-07 Contents Contents Introduction... 1 Part 1 General Information... 2 Part 2 General Instruction... 13 Part 3 Outdoor Units... 17 Part 4 Installation... 316 Part 5 Control System... 356
More informationGas Pressure Regulator RMG 201
Product information serving the gas industry worldwide Application, characteristics, technical data Application application in industrial stations for small flowrate regulating lines in gas pressure regulating
More informationSimple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18
The Bray Simple Set Max is a flanged pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SSM Series combines high rangeability
More informationD A T A S H E E T. Technical Data. Maximum Working Gauge Pressure (bar) Capillary Tube Length (m) 1.5 (5Ft) Burst Gauge Pressure (bar) 234.
TRAE Stretch series of Thermal Expansion Valves are designed predominantly for AC, heat pumps, close control, industrial process cooling applications, and transportation AC with HP demand. The new TRAE
More informationsmartdraft TM Tap & One-way beer line Infosheet
smartdraft TM Tap & One-way beer line Infosheet smartdraft Tap & One-Way Beer Line Infosheet Dimensions: Tap: One-way beer line: Weight: Tap: One-way beer line: Pressure: Standard: Tolerance: Other on
More informationOPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N
OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80589-02 Table of Contents Components... 2 Test... 4 Recovery/Recycling... 5 Evacuation... 7 Charging...
More informationSERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz.
SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A5-T5-W5, ICE0400A4-T4-W4 MODEL - ICE0500A4-T4-W4-R5, ICE0606A4-T4-W4-R5 Includes 50Hz. Units Date 1/09 Table Of Contents This parts list contains
More informationGas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Gas powered stop valves, type GPLX 80-150 REFRIGERATION AND AIR CONDITIONING Technical leaflet Technical leaflet Gas powered stop valves, type GPLX 80-150 Contents Page Introduction........................................................................................3
More informationVariable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design
Brueninghaus Hydromatik Series 1, for open circuits Axial piston - swashplate design, Back to back - design RE 93100/02.97 Sizes 60...260 Nominal Pressure up to 350 bar Peak Pressure up to 400 bar Preliminary
More informationUltraLo 1800 Alpha Particle Counter
XIA LLC UltraLo 1800 Alpha Particle Counter Site Requirements & Planning Version: 0.4 Friday, February 15, 2013 Table of Contents I. Site Preparation Tasks... 3 A. Instrument Overview... 3 B. Installation
More informationTurbo Blowers. Combustion Excellence Since Features. Benefits
Turbo Blowers Features Integral molded scroll design Turbine bladed impeller Steel inlet guard Precisely balanced impellers eliminate vibration Complete line of available accessories for adapting to any
More informationAccessories for BHD Linear Drive Systems Series OSP-E..BHD
for BHD Linear Drive Systems Series -..BHD Contents Description Page nd Cap Mountings 36 Mid-Section Support 37 Adaptor Profile 38 T-Nut Profile 39 Motor Mountings Coupling Housing 40 Profile Mountings
More informationsafety Shut-Off Valve HON 721
safety Shut-Off Valve HON 7 product information serving the gas industry worldwide safety shut-off valve HON 7 safety shut-off valve HON 7 Application, Characteristics, Technical Data Application safety
More informationResearch of Variable Volume and Gas Injection DC Inverter Air Conditioning Compressor
Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2016 Research of Variable Volume and Gas Inection DC Inverter Air Conditioning Compressor
More informationSeries SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100
Clean Air Filter Variations SFD SFD SFD SFD Made to Order Type Disposable (non-replaceable element) Cartridge (replaceable element) Flow rate L/min (ANR) (at inlet pressure.7 MPa) Up to 6 Up to 8 Up to
More information2-Port Seat Valves with Flange, PN 16
4 45 2-Port Seat Valves with Flange, PN 6 VVF45... dular cast iron EN-GJS-400-5 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SKB...- or SKC...- electrohydraulic actuators Use For use in
More informationQuick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING Technical leaflet Introduction QDV is a quick closing oil drain valve, designed particularly for draining oil from systems
More informationFSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities
TECHNICAL SPECIFICATIONS FSH1BG Series FEATURES and BENEFITS Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities 1 The iq Drive heat pump system features modulating compressor
More informationDucted Reverse Cycle Air Conditioning of Distinction
Ducted Reverse Cycle Air Conditioning of Distinction Transforming global energy-efficiency into an art form! The Braemar advantage Braemar ducted reverse cycle air conditioners are brought to you by Seeley
More informationAir Differentail Pressure Switch
Page 1 of 5 PA-DPS-8x Air Differentail Pressure Switch Features: Benefits: Close switching differential Duct fixing kit included Switching point easily adjusted with scale in Pascals Conduit entry can
More informationOverflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Overflow valves Type OFV 20-25 Type OFV-SS 20-25 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction.......................................................................................
More informationBL68 - Olympian Plus, plug-in system Filter/regulators and lubricators
>> Port size: 3/4... /2 (ISO G/ PTF) >> Complete air processing units pre-assembled, ready to install Technical features Medium: Compressed air only Maximum operating pressure: 7 bar (246 psi) Pressure
More informationE SERIES. Specification. E Series. Relief and Flow Control Valves O M O M EIC-H Model No. Description
4 Ω-1 Ω Series Proportional Electro-ydraulic This relief and flow control valve is an energy-saving valve that supplies the minimum pressure and flow necessary for actuator drive. Since this valve controls
More informationFlow control valves Series RFU - RFO 2/
CATALOGUE > Release 8.5 > Valves Series RFU - RFO Flow control valves Series RFU - RFO Unidirectional and bidirectional flow control valves Ports: M5, G1/8, G1/4, G3/8 and G1/ Nominal diameter: M5 = 1,5
More informationLiquid level regulating valves Types PMFL / PMFH and SV
Data sheet Liquid level regulating valves Types / PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant, a system comprising a liquid level regulating valve
More informationV46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings
Installation Instructions V46 Issue Date 11//1 V46 Series -Way Pressure-Actuated Water-Regulating Valves With Union Fittings Application IMPORTANT: The V46 Series -Way Pressure-Actuated Water-Regulating
More informationShut-off Liquid level and regulating valves for for Industrial Refrigeration
Catalogue Shut-off Liquid level and regulating valves for for Industrial Refrigeration Contents Page Float valve, type HFI... 3 Float valves, types SV 1 and 3... 17 Float valves, types SV 4, SV 5 and SV
More informationTECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)
Page 1 of 8 1. DESCRIPTION The Viking Model F-1 Deluge Valve is a quick opening, differential diaphragm, flood valve with one moving mechanism. The Deluge Valve is used to control water flow in Deluge
More information2-Port Seat Valves with Flange, PN 16
4 40 2-Port Seat Valves with Flange, PN 6 VVF4... Grey cast iron EN-GJL-250 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SQX- electromotoric or SKD...-, SKB...- or SKC...- electrohydraulic
More informationRTG 25. Introduction
Introduction RTG 25 pressure regulator is included within the direct acting and balanced valve regulator class. These regulators have a large range of applications both in industrial and domestic installations.
More informationGlass tube flowmeters Series 2000
Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases Short mounting length and compact construction, especially indicated for control panels Easy installation. No
More informationATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE
ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in
More informationLevel transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids
Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids No contact with the product Compact design with polycarbonate housing (electronics and display).
More informationFMU4X, FMC4X FMU4P, FMC4P
ENVIRONMENTALLY SOUND REFRIGERANT FMU4X, FMC4X FMU4P, FMC4P Product Specifications HORIZONTAL FAN COILS FMU4P and FMC4P 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2 and 2 1/2 Tons ALL MODELS Horizontal
More informationTF- & DM-Series. Turbineflowmeter
Turbineflowmeter .. are the ideal solution for measuring applications in liquids when high accuracy, very fast response times, compact design, high reliability are also required in continuous operation
More informationMULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE
SIT Group SIT -3- SIGMA MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE 9.955. Subject to change without notice Application Domestic gas appliances: central heating boilers, combi boilers, instantaneous
More informationSystem Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner
System Soft-optimization Tests of Refrigerant R-32 in a 6-ton Rooftop Packaged Air-Conditioner Mohammad Khawaldeh Director, Unitary & Applied Product Units Presentation Outline Objectives Challenges Base
More informationModulating liquid level regulators, servo-controlled PMFL / PMFH and SV
MAKING MODERN LIVING POSSIBLE Technical brochure Modulating liquid level regulators, servo-controlled / PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant,
More informationV48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings
Installation Instructions V48 Issue Date 08/30/01 V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings Application IMPORTANT: The V48 Series 3-Way Pressure-Actuated Water-Regulating
More informationPORTABLE GAS FREEING FAN
PORTABLE GAS FREEING FAN TYPE MPV APPLICATIONS Typical application for this fan is mechanical ventilation of hazardous zones and cargo tanks onboard ships. To be mounted into tank openings on deck. DESIGN
More informationTHE COMPACT LINE. Mobile power packs in convincing BAUER quality l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED
THE COMPACT LINE Mobile power packs in convincing BAUER quality 100 140 l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED COMPACT LINE mobile breathing air compressors for high demands Due to its legendary
More informationUniflair LE TDAR-TUAR
Uniflair LE TDAR-TUAR Direct Expansion air-cooled units with backward-curved fans 20-100kW > Perimeter cooling for medium/large data center > Refrigerant R-410A Available Versions: > Downflow (TDAR) >
More informationRMP/PSM WEBINAR SERIES
RMP/PSM WEBINAR SERIES Webinar Starts at 08:00 PT Please call (877) 532-0806 if you are having technical issues. The background music may be used to adjust your audio volume. IIAR STANDARDS AND HOW THEY
More informationAll technical data may be changed MADE IN ITALY BY NARDI COMPRESSORI
PACIFIC MX NITROX BREATHING AIR according to DIN EN 12021 MAX OXYGEN 40% DELIVERY l/min 600 m 3 h 36 PRESSURE BAR 225 PSI 3250 Quality system certified to iso 9001 BREATHING AIR is a product line that
More informationSales Office: Danfoss Expansion Valves. T*2 Range Order valve and orifice separately Range N -40 C to +10 C Without MOP
Danfoss Expansion Valves T*2 Range Order valve and orifice separately Range N -40 C to +10 C Without MOP Code Model Connections Danfoss No Internally Equalised F500 TX2 R22 3/8 x 1/2 flare 068Z3206 F502
More informationG SERIES METRIC MACHINE SCREW ACTUATOR
G SERIES METRIC MACHINE SCREW ACTUATOR kn to 0kN Duff-Norton metric actuators are manufactured to the same high quality standards and include all the same features and benefits as the standard line of
More informationRobLight FL 1500 B-2. User manual. Applies to: RobLight A/S Nordhavnsvej 1A DK Frederikshavn. Phone:
98082129 22-08-2018 Rev. 2.6 User manual FL 1500 B-2 A/S Nordhavnsvej 1A DK - 9900 Frederikshavn Applies to: + 0130 0058 FL 1500 B-2 3000K CRI 90+ + 0130 0068 FL 1500 B-2 4000K CRI 90+ + 0130 0658 FL 1500
More informationCO 2 radial piston compressor (transcritical)
CO 2 radial piston compressor (transcritical) At a glance Operating limits and performance data Technical data Dimensions and connections Scope of supply 124 126 129 130 131 Radial piston compressor (transcritical)
More informationVacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation
Cryogenics Vacuum Dry Turbo Pumping Stations Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators Hermetically Sealed Pumps for He3 Recirculation Oils, Filters and Traps Valves, Fittings and Adaptors
More informationMeasurement of Low GAS & Liquid Flows
Measurement of Low GAS & Liquid Flows The Measurement Measurement with a float in a tapered borosilicate glass tube. Series 2100 with a 100 mm flow tube Series 2150 with a 150 mm flow tube Series 2300
More informationDF-310E PROCESS ANALYSERS APPLICATIONS FEATURES
PROCESS ANALYSERS DF-310E The DF-310E is a Coulometric sensor based oxygen analyzer designed to measure trace and percent level oxygen in pure and multi-gas backgrounds for process and quality control
More informationVERTICAL TURBINE PUMPS Right Angle Gears. Shaft Guarding for Horizontal Mounted Spicer Universal Joint Drive Shafts
Peerless Pump Company Indianapolis, IN 46207-7026 VERTICAL TURBINE PUMPS Right Angle Gears SECTION 110 Page 1 January 2, 2007 Shaft Guarding for Horizontal Mounted Spicer Universal Joint Drive Shafts A
More informationPVQ 13 A2 R SE 1 S 20 C-11 D
PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard
More informationEvaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction...3 Features...3 Technical data...4 Ordering...4 Sizing...5 Valve selection...5
More informationA soft sealed atmospheric safety valve with large flow capacity and soft seat tightness for steam condenser and turbine applications
SAPAG A soft sealed atmospheric safety valve with large flow capacity and soft seat tightness for steam condenser and turbine applications Features The Sapag Series 1100 steam safety valve is used for
More informationINSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN
INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN Important: Read all instructions and refer to local codes prior to installation. l Local soil conditions may require more gravel for drainage. l
More informationGovernor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG
Governor with solenoid valve Air/gas ratio control with solenoid valve VAG All-purpose servo-governor for gaseous media with integrated safety valve Suitable for a max. inlet pressure of 500 mbar Outlet
More informationCapacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Capacity regulator (hot gas bypass), type TUH/TCHE/ REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3
More informationGEAR PUMPS. Displacement from 5 to 39 ccm Pressure up to 280 bar Speed from 400 to 3000 RPM
Displacement from 5 to 39 ccm Pressure up to 280 bar Speed from 400 to 3000 PM GEA PUMPS TABE OF CONTENTS DESCIPTION......................................................................................................................
More informationCoils Designed to Fit Your Requirements. Temtrol Manufacturing OEM & Replacement Coils Since 1955
Temtrol Manufacturing OEM & Replacement Coils Since 1955 Coils Designed to Fit Your Requirements Chilled & Hot Water Direct Expansion Steam Distributing Condenser Standard Steam Quick Ship Program with
More informationEarlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System.
17 1 Earlier Lecture In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System. Collins system is an extension of the Claude system to reach lower
More information