No./DMER/Tender Notice/ CORRIGENDUM/Equip.Pur/17-18/7M Date :-11/08/2017. E-Tender Notice CORRIGENDUM REGARDING SPECIFICATIONS FOR

Size: px
Start display at page:

Download "No./DMER/Tender Notice/ CORRIGENDUM/Equip.Pur/17-18/7M Date :-11/08/2017. E-Tender Notice CORRIGENDUM REGARDING SPECIFICATIONS FOR"

Transcription

1 No./DMER/Tender Notice/ CORRIGENDUM/Equip.Pur/17-18/7M Date :-11/08/2017 E-Tender Notice CORRIGENDUM REGARDING SPECIFICATIONS FOR Sr. E-Tender No. Name of Instruments/ Equipments No. 01 EQC-25(17-18) Transport Portable Ventilator 02 EQC-26(17-18) Mobile Digital Radiography System 03 EQC-27(17-18) Automate Follicular Transplant Machine 04 EQC-28(17-18) Auto Strainer (Automatic Staining Machine) 05 EQC-29(17-18) Operating Microscope 06 EQC-32(17-18) 4-D Color Doppler Ultrasound Sonography Machine 07 EQC-34(17-18) Ventilator Adult/Pediatric Intensive Ventilator with ET 1. Directorate of Medical Education & Research, Mumbai, invited e-tender in two envelope systems from the manufacturers / authorized dealers and suppliers to supply instruments/ equipments for the Government Medical and Dental Colleges. This notice is available on the e-tender site i.e & govt. in and also notified in Maharashtra Govt. Gazette supplement - II 2. All the tenderers are hereby informed that modifications made in the specifications after the Pre-Bid meeting held on 10 August 2017 at a.m & 11 August 2017 at a.m are as follows. 1. e-tender- EQC-25(17-18)Transport Portable Ventilator Sr.No. Previous Specifications Revised Specifications 3 Technicial Specification a)ventilation Mode :- CPAS,S, S/T,PC,T & AVAPS-AE IPAP;4-40cmH2O Spontaneous, Pressure support, Spontaneous /time pressure a)ventilation Mode :- CPAP, S, S/T, PC, T & VAPS-AE IPAP;2-40cmH2O Spontaneous, Pressure support, Spontaneous /time pressure support, Time pressure support, Pressure Control support, Time pressure support, Pressure Support and Hybrid Ventilation mode ( Volume assure pressure support ) Control Support and Ventilation mode ( Volume assure pressure support ) b) EPAP cm H20 b) EPAP cm H20 e) Target Tidal voulme : ml e) Target Tidal volume : ml i) Bi Flex Pressure Relief : 0-3 i) Pressure Relief : 0-3 Should automatic EPAP and automatic respiratory rate to airway resistance. i) Should have detachable battery backup of at least 4 hrs or more. ii) Should have options of nurse call connector. iii) Must have USFDS and CE. Additional Points Should have automatic EPAP and automatic respiratory rate to airway resistance. i) Should have detachable battery backup of at least 4 hrs or more. ii) Should have options of nurse call connector (optional) iii) Must have USFDA and CE. n) FI02 monitoring Kit inbuilt

2 4 Accessories ( optional with additional cost) a) FlO2 monitoring kit b) Oxygen Enrich port for supply supplement oxygen c) System one integrated heated humidifier d) Oximetory device for monitor SpO2 and Heart Rate e) Nurse Call Cable. f) Full face Mask Large, Small and medium each 2 units g)whisper swivel port for exhalation - 2 units. h)flexing tube 2 units. i) Bacterial filter 2 units j) A-40 Stand Rest of the specification are same o) NIV Face Mask Large, small & medium - 2 units each. a) Oxygen Enrich port for supply supplement oxygen b) System one integrated heated humidifier c) Oximetry device for monitor SpO2 and Heart Rate d)whisper swivel port for exhalation - 2 units. e) Flexing tube - 2 units. f) Bacterial filter units g) Stand 2. e-tender- EQC-26(17-18)/Mobile Digital Radiography System Sr.No. Previous Specifications Revised Specifications A) Generator: A) Generator: 4) It should have an electronic timer with shortest exposure time 1 ms or less. 4) It should have an electronic timer with shortest exposure time 2 ms or less. B) X Ray Tube: B) X Ray Tube: 1) Output should match the output of the 1) Output should match the output of the generator. 3) Dual Focal spot X Ray tube with 1 mm or less for small focus and 2 mm or less for large focus. 3. e-tender- EQC-27(17-18) Automate Follicular Transplant Machine generator.(please Specify) 3) Dual Focal spot X Ray tube with 0.6 mm or less for small focus and 1.2 mm or less for large focus is preferable.(please specify) Hand piece Extraction, Implantation Minimal Acceptable Suction 800 mbar Minimal Acceptable Pressure 3 bar/40 psi Rotation per minute Max 10,000 to 20,000/minute Vacuum 650Mbar Pressure (to be used for implantation) KBar Electrical consumption watts Display LCD Touch Screen Power Supply AC Volt,50/60 Hz Harvesting Punches 0.8 mm,0.9 mm,1 mm,1.25 mm (2 each) Implantor 2 hand pieces Implantar Heads 0.8 mm,1mm,1.25mm (2 each) Foot pedals 2 warranty 2 years + 3 years CMC service FDA Classification Class 1 or class 2 UPS 1 Power stabilizer 1 Harvesting speed 600 to 2200 grafts per hour Patient Date Recording System Inbuilt Sterilization Autoclavable Depth Control of grafts (Adjustable options by surgeon's choice)

3 4. e-tender- EQC-28(17-18) Revises Spec.Auto Strainer (Automatic Staining Machine) All bidders should quote as per revised specification as follows Autostainer (Automatic Multi Staining Machine)Technical/Locking Specifications for Autostainer Consistent, high quality results for both routine and special stains and can perform single or multiple protocols at the same time. Safer staining process. Significantly reduce the potential for user errors as it automatically/alternate method to identify the desired stain protocol for individual racks and automatically/ alternetively starts the correct process. Simple programming Operational safety is enhanced by the smart graphical user interface featuring intuitive software visualization with a color TFT touch-screen, multilingual software and context sensitive online help. Match your Laboratory s needs Enjoy flexibility with multiple bath layout with 40 stations including 5-6 wash stations and 2-4 ovens/slide drying stations Saves costs and energy Significantly reduce fume exposure with the easy load and unload draws that hold up to 120 slides. Consistent quality and convenience The reagent management system (RMS) helps to monitor reagent expiration, reagent rotation and stain quality. As a result, reagent changes minimize disruptions to workflow and reduce delays. The RMS in conjunction with validated surgipath reagents and protocols, ensures superior staining and coverslipping quality. CodeRack technology Racks are automatically/alternate method, assigned to the correct staining protocol. Robotics Arms The innovative and patented robotic arm moves the slides through the staining cabinet precisely according to the staining protocol. It is possible to process up to 12 racks simultaneously with multiple staining applications. Capapcity Data Loading capacity : max 12 slide racks with 25 different protocols Slide rack capacity : 30 specimen slides Total no. of stations : reagent station & 5 6 Wash station oven Total no of reagent station : Reagent container volume : 450 ml Number of wash station : 5 6 Staining stations : Container volume : ml Water stations : 5 6 Oven stations : 2 4 Oven temperatures : 40 to 70 degree Celsius (104 F to 158 F) Load stations : 2-4 Unload stations : 2 4 1) It must be upgradable/attachable to cover slippers. 2) It must have CE / FDA certification. 3) Company must have atleast 10 yrs. of standing & service backup facility (with qualified engineers) for servicing & maintaining the machine regularly. 4) Satisficatory performance/demonstration of machine is mandatary. User can reject the manchine on this basis alone even if specification are matching.

4 5. e-tender- EQC-29(17-18) Revised Specification of Operating Microscope All bidders should quote as per revised specification as follows 1. MICROSCOPE BODY: Motorized zoom 1:6 magnification system with apochromatic optics, 2 x 16 and manual override facility working distance from 207 mm to 470mm without exchange of objective lens, integrated continuously variable illumination field from 60mm-155mm or less. 2. BINOCULAR TUBE: degree tilt able binocular tube with focal length mm or higher Graduated knob for continuous adjustment of interpupillary distance from 55 mm to 75mm. 3. EYEPIECES: 12 x magnification, diopter setting from- 5D to +5D, also suitable for spectacles wearers. 4. ILLUMINATION SYSTEM: Coaxial xenon, illumination 300W with back up of 300W xenon lamp 5. HANDGRIPS: Easily maneuverable handgrips with adjustable keys for zoom and focus illumination & magnetic brakes. Programming for magnetic brake for control of stand & Microscope body brakes. 6. FLOOR STAND: Roll able floor stand on base with lockable castors, carrier and swivel arms with large reach of 1.40m or higher, should have free float magnetic system with six magnetic brakes. Three brakes for microscope body & three for microscope stand with, release of magnetic brakes by handgrips. Weight of microscope should be kgs. 7. BALANCE SYSTEM FOR MICROSCOPE: Intra operative balancing system for microscope with user prompt, quick set up of different parameters and their activation at press of a button such as automatic speed adjustment or automatic brightness setting depending on magnification. 8. VIDEO CAMERA SYSTEM: C mounted CMOS camera of same company full HD video camera with LED display and appropriate recording systems 9. USER PROGRAMMING: Programming for starting illumination, Magnification, working distance, zoom speed & focus speed for at least 8-9 different users. 10. STEREO CO OBSERVER ATTACHMENT: Apart from the main surgeon. 11. Field diameter automatically adjusted to the field of vision & manually Adjustable 12. Zoom & working distance (Focus should be motorized & manual control in case of malfunction of electrical motor. i.e. Manual over ride facility should be must for an emergency.) 13. At least one or more installation report of government of Maharashtra along with the performance certificate should be submitted. 14. Should have completely integrated beam splitter and face-to-face attachment. 15. Should have integrated electronically controllable diaphragm to adjust depth of field. 16. Should have system for data exchange with the hospital network. 17. Should have Back up UPS system for power supply

5 6. e-tender- EQC-32(17-18) 4-D Color Doppler Ultrasound Sonography Machine Sr.No. Previous Specifications Revised Specifications 3 System must have Convex transducer with High Density crystal technology or pure wave technology or matrix technology for excellent grayscale Image quality on Difficult to image patients ( Kindly Specify).Please mention the High Density crystal technology or pure wave technology or matrix technology being used in the transducer. Original technical data sheet should be enclosed in technical bid to support the technology ( Kindly Specify). System must have Convex transducer with High Density crystal technology or pure wave technology or matrix technology for excellent grayscale Image quality on or equivalent technology. Difficult to image patients ( Kindly Specify).Please mention the High Density crystal technology or pure wave technology or matrix technology being used in the transducer. Original technical data sheet should be enclosed in technical bid to support the technology ( Kindly Specify). 15 System must be offered with user friendly high resolution user interface touch panel which is minimum 11 inch.user friendliness will be given priority. SYSTEM MUST BE THE FOLLOWING COMPULSORY TRANSDUCERS 1 to 5 MHz Convex Transducer for General Imaging, Renal, OB/GYN, abdominal imaging with capabilities of CEUS and ARFI or equivalent Elastography imaging for assessing diffused liver and its stiffness. Must have Tissue Harmonic Imaging. Field of view should be 100 degree. This transducer should have either single crystal technology or purewave or matrix technology for excellent graysclale Image quality on difficult to image patients. Please mention the crystal or matrix technology used in the transducer by attaching technical data sheet of trasducer.( Kindly Specify) SYSTEM MUST BE THE FOLLOWING COMPULSORY TRANSDUCERS 1 to 6 MHz Broadband Mechinical/ motorised Volume or Matrix Transducer for General Imaging, Abdomen, Renal. OB/GYN imaging with minimum 5000 plus crystals.this probe must simultaneous display two orthogonal real t ime 2D live high quality image planes. Must have Tissue Harmonic Imaging and minimum 100 volume per second. Should attach technical data sheet of transducer to specify and the vendor must supply the probe with the widest field of view in the above frequency range.among the above Transducers lighter weight transducers will be prederred.(kindly Specify) System must be offered with user friendly high resolution user interface touch panel which is minimum should be 10 inch. & above. User friendliness will be given priority. SYSTEM MUST BE THE FOLLOWING COMPULSORY TRANSDUCERS 1 to 5 MHz Convex Transducer for General Imaging, Renal, OB/GYN, abdominal imaging with capabilities of CEUS and ARFI or equivalent Elastography imaging for assessing diffused liver and its stiffness. Must have Tissue Harmonic Imaging. This transducer should have either single crystal technology or purewave or matrix technology for excellent graysclale Image quality on difficult to image patients. Please mention the crystal or matrix technology used in the transducer by attaching technical data sheet of trasducer.( Kindly Specify) SYSTEM MUST BE THE FOLLOWING COMPULSORY TRANSDUCERS 1 to 6 MHz Broadband Mechinical/ motorised Volume or Matrix Transducer for General Imaging, Abdomen, Renal. OB/GYN imaging with minimum 5000 plus crystals.this probe must simultaneous display two orthogonal real t ime 2D live high quality image planes. volume per second. Should attach technical data sheet of transducer to specify and the vendor must supply the probe with the widest field of view in the above frequency range.among the above Transducers lighter weight transducers will be prederred.(kindly Specify)

6 7. e-tender- EQC-34(17-18) Revised Specs Adult/Pediatric Intensive Ventilator with ETCO2 All bidders should quote as per revised specification as follows Should be suitable for use in Adult & Paediatric patients in all critical care areas Ventilator should have integrated mainstream EtCO2 monitoring. The ventilator should be user friendly, easy to handle and have flexibility in operation Should have both invasive and non invasive ventilation modes. Ventilator should have screen with minimum 12 display of waveforms (pressure, flow and volume) & loops (PV, FP & loop) with freeze and reference capability Ventilator should have multiple screen to view 1. 3 waveforms + monitoring parameters 2. 2 loops + monitoring parameters 3. 1 loop + 3 waveforms + parameters Ventilator should have an inbuilt turbine or compressor based delivery system from the same manufacturer. The ventilator should have minimum internal battery backup of 4 hours with onscreen battery power indication. Machine should have following ventilation modes: 1. Pressure Supported Ventilation (PSV) 2. Volume controlled Ventilation (VCV) 3. Pressure controlled Ventilation (PCV) 4. Volume controlled assist control (VC-A/C) 5. Pressure controlled Assist control (PC-A/C) 6. Duo Level/Bi Level/Biphasic Positive Airway Pressure or Equivalent. 7. Synchronized Intermittent Mandatory Ventilation (SIMV) in both Volume Control and pressure control mode with pressure support 8. APRV (Airway pressure release ventilation mode) 9. PRVC (Pressure regulated volume control mode) in both volume controlled & SIMV 10. Non invasive Ventilation (NIV) 11. Apnea ventilation in both volume controlled and pressure controlled with automatic return to support mode on patient triggering. Ventilator should have visual guide to aid in carry out self test Ventilator should have ideal Body weight setting for fast ventilation Ventilator should have an inlet for low pressure oxygen source Both Inspiratory and Expiratory valve of ventilator should be easily detachable w/o tool and support autoclave sterilization to reduce the chance of cross-contamination Monitoring and display of following parameters: 1. Oxygen concentration; 2. Tidal Volume (inspired and expired) and spont 3. Pressure peak and plateau and mean airway pressure; 4. Respiratory rate-mandatory and spont. 5. PEEP; 6. Minute ventilation (MV, MVspn, MVleak); 7. Compliance both static and Dynamic 8. Resistance- Ri and Re Machine should have following procedures: 1. Insp and Exp Hold 2. Auto PEEP 3. NIF (Negative Inspiratory Force) The equipment should provide at least the following controls and ranges: 1. Tidal volume (20ml 2000ml) 2. Inspiration time ( sec)

7 3. Ventilation rate (1-100 bpm) 4. Flow trigger (0.5 to 15 lt/min) 5. Pressure trigger (-10 to 0.5 cm H20) 6. Oxygen concentration (21 100%) 7. Inspiration/ Expiration ratio (1:104:1); 8. Exp termination criteria (Auto, 10% to 85%) 9. Apnea alarm time (5s-60s) 10. Tpause (5%-60%, off) The Equipment should provide at least the following audiovisual alarms: 1. Sensitive alarms with adjustable high and low limits a) Peak airway high pressure; b) High/low Tidal Volume; c) Low/high Minute Volume; d) High/low Oxygen concentration; e) Low PEEP/CPAP; 2. Other alarms a) Low airway pressure; b) Power loss; c) Low oxygen pressure; d) Apnea; e) Battery low; f) Sustained pressure. Should have a facility to view trended and graphical data up to 24 hrs. Should have integrated Oxygen therapy or equivalent to enhance recovery phase, avoid reintubate and PONV Should have facility to compensate tube resistance with settings of Tube type, I. D. & compensation. Ventilator should have integrated port for jet nebulisation with inspiratory synchronized and setting of duration of nebulisation time. Ventilator should have facility for communication via RS232, Ethernet, USB Port. Ventilator should have facility to export screen shots, patient demographics, trends and logbook via USB, Machine should be European CE and US FDA approved. The equipment should be supplied with following parts/accessories 1. Inbuilt Trolley 2. O 2 sensors Flow sensor - 2 (reusable) 4. ETCO 2 sensors 2 reusable 5. Expiratory valve 6. Inbuilt tube-holder arm Reusable patient circuit 2 no each (Adult and pediatric) Nebulizer Instruction for use Face and Nasal Mask for NIV Two sets of disposable masks of all sizes (Small, medium and large) Disposable patient circuit: Adult - 50, Paediatric - 20 HEPA filters - 50 UPS: True on line ups with isolation transformer for complete system including air source for complete protection against all types of input supply variations Literature: Operating Manual, Service Manual and list of installations in state & country should be given. Past record: User friendly with good past record for after sales service. Demonstration: Physical demonstration of complete system with all accessories as quoted

8 must be given to technical committee well within the time limit prescribed. Warranty: Comprehensive Warranty for 2 years Comprehensive Maintenance Contract: Should include comprehensive maintenance contract for 8 years. Installation Base: 1. Should have at least 20 installation of quoted model in use for last one year in India 2. Cost of the consumables should be quoted separately and will be frozen for 05 years. 3. Scope of supply should be written in details otherwise tender document remain incomplete. The same will be sent to the user with purchase order. 4. For all imported equipment the bidder has to submit bill of entry copy for equipment imported in last 2 years. 5. Successful bidder will be required to submit custom duty clearance copy along with supplies of equipment or else payment will not be released. 5. All the tenderer should note the above modifications in the Specification and do accordingly. 6. The Directorate of medical Education & Research reserves the right to increase or decrease the quantity of tendered equipments and reserves the right to reject the tender without any reason thereto. For e-tendering help/information, please contact. Website:- Contact No.: (Ext. 338 / 339 / 340 ) Sd/- Director Medical Education & Research, Mumbai

No./DMER/Tender Notice/Equip.Pur/14-15/Corri./7M Date :- 20/09/2014

No./DMER/Tender Notice/Equip.Pur/14-15/Corri./7M Date :- 20/09/2014 No./DMER/Tender Notice/Equip.Pur/14-15/Corri./7M Date :- 20/09/2014 E-Tender Notice CORRIGENDUM REGARDING SPECIFICATIONS FOR 1. EQ-C-66 Bubble C PAP 2. EQ-C-68 Neonatal High frequency ventilator 3. EQ-C-70

More information

Technical Data and Specifications

Technical Data and Specifications Technical Data and Specifications INTENDED USE Ventilator designed to provide Invasive and Non-invasive ventilation for the critical care management of adult, pediatric and neonate-infant (including premature)

More information

Panther 5 Acute Care Ventilator

Panther 5 Acute Care Ventilator 1 HIGHLIGHTS High performance and advanced features target the ICU environment Utilizes an internal blower with a specially designed flow control valve removing the need for using compressed air without

More information

INTENSIVE CARE VENTILATORS

INTENSIVE CARE VENTILATORS INTENSIVE CARE VENTILATORS iternis ADV INTENSIVE CARE VENTILATION FOR ALL PATIENT CATEGORIES Design Features HEYER iternis ADV s 12-inch touch-screen display combines comprehensive, easy-to-follow user

More information

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR: PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: 1. **Identify and name the filters on the 7200ae. 2. **Explain how each filter is sterilized. 3. **Trace the gas flow through the ventilator

More information

V8800 Ventilator System. Your healthcare, we care.

V8800 Ventilator System. Your healthcare, we care. V8800 Ventilator System Your healthcare, we care. V8800 Ventilator System V8800 is a critical care ventilator for infants, children and adults. It has comprehensive functionality, a user-friendly design,

More information

Milestones of Aeonmed Ventilators

Milestones of Aeonmed Ventilators Aeonmed Development History Milestones of Aeonmed s 2003 More than 1000 Aeonmed ventilators contributed to save lives during SARS 2008 Aeonmed nominated emergency ventilator supplier for 2008 Beijing Olympic

More information

Airox Supportair Ventilator

Airox Supportair Ventilator Airox Supportair Ventilator A versatile hospital ventilator with a titration platform that enables a smooth transition to the patient s home care ventilator Titration Platform The Supportair ventilator

More information

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV VENTIlogic LS VENTIlogic plus 100 % Mobility and Reliability in IV and NIV VENTIlogic VENTIlog LS Your Requirements for Reliability and Mobility are Our Benchmark. VENTIlogic LS and VENTIlogic plus are

More information

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations GE Healthcare Centiva/5 Critical Care Ventilator Meet a new level of expectations Intergrating performance and value Marry form and function In an environment where time and space are tight, the design

More information

WILAmed INTENSA. Intensive Care Ventilator System

WILAmed INTENSA. Intensive Care Ventilator System EN WILAmed INTENSA Intensive Care Ventilator System 0197 WILAmed INTENSA Ventilator System The WILAmed INTENSA is a full invasive and non-invasive life-support ventilator, solely designed for the ventilation

More information

Department of Paediatrics

Department of Paediatrics KASTURBA HEALTH SOCIETY'S MAHATMA GANDHI INSTITUTE OF MEDICAL SCIENCES, P.O. SEVAGRAM, WARDHA (DISTT.) MAHARASHTRA STATE - 442 102 Specifications for Equipment Department of Paediatrics 1. A) Ventilator

More information

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters SLE4000 Infant Ventilator with touch-screen operation When the smallest thing matters SLE4000 - The Total Solution for Conventional Infant Ventilation SLE is a world leader in the design and manufacture

More information

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients Expanding versatility The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients Trilogy Series is a family of remarkably versatile life support ventilators that simplifies

More information

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation V8600 Ventilator Integrated Invasive & Noninvasive Ventilation 0123 V8600 Ventilator Invasive Ventilation With state-of-the-art turbine technology, V8600 helps achieve sequential ventilation in various

More information

A9600 Anesthesia Workstation. Your healthcare, we care.

A9600 Anesthesia Workstation. Your healthcare, we care. A9600 Anesthesia Workstation Your healthcare, we care. A9600 is an advanced yet easy to use anesthesia workstation that provides accurate, pneumatically driven and electronically controlled ventilation.

More information

SLE5000 Infant Ventilator with HFO

SLE5000 Infant Ventilator with HFO SLE5000 Infant Ventilator with HFO When the smallest thing matters SLE5000 - The Total Solution for Infant Ventilation Shown on optional roll stand. Ventilator may be mounted either way round on stand.

More information

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE Critical Care SERVO-s 3 SERVO-s SIMPLY MAKES SENSE MAQUET THE GOLD STANDARD Leading the way: MAQUET is a premier international provider of medical products

More information

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV VENTIlogic LS VENTIlogic plus 100 % Mobility and Reliability in IV and NIV VENTIlogic LS VENTIlogic plus Your requirements for reliability and mobility are our benchmark. VENTIlogic LS and VENTIlogic plus

More information

EVE. The mobile Ventilation Concept from Emergency to Intensive Care. easy - light - smart. Ventilation

EVE. The mobile Ventilation Concept from Emergency to Intensive Care. easy - light - smart. Ventilation Ventilation EVE easy - light - smart The mobile Ventilation Concept from Emergency to Intensive Care + Ventilation at the push of a button + Cutting edge turbine technology + Critical care during transport

More information

Update to RS-232 commands. Changing patient from NIV to INVASIVE Vent Type. SNDF command

Update to RS-232 commands. Changing patient from NIV to INVASIVE Vent Type. SNDF command Changing patient from NIV to INVASIVE Vent Type Table 9 shows automatic settings changes that occur when changing the same patient from NIV to INVASIVE Vent Type. Table 9: Automatic settings changes NIV

More information

2015 Hamilton Medical AG. All rights reserved. Printed in Switzerland.

2015 Hamilton Medical AG. All rights reserved. Printed in Switzerland. HAMILTON-T1 Quick Guide This Quick Guide is intended as a useful reference for ventilation of adult and pediatric patients. It does not replace the clinical judgment of a physician or the content of the

More information

HAMILTON-MR1. Technical specifications HAMILTON-MR1

HAMILTON-MR1. Technical specifications HAMILTON-MR1 HAMILTONMR1 HAMILTONMR1 Technical specifications The HAMILTONMR1 guarantees uncompromised continuous ventilation care from the ICU to the MRI scanner and back. Its reliability and high performance, with

More information

Meet the changing needs of your patients. Trilogy Series, with advanced ventilator technology

Meet the changing needs of your patients. Trilogy Series, with advanced ventilator technology Meet the changing needs of your patients Trilogy Series, with advanced ventilator technology Trilogy100 and Trilogy200, unique features for unique patients The Trilogy Series, versatile life support ventilators

More information

fabian Therapy evolution Our 2-in-1 device

fabian Therapy evolution Our 2-in-1 device fabian Therapy evolution Our 2-in-1 device Ventilation Beyond Limits When It Comes to Life, There Is No Compromise Distributing worldwide ACUTRONIC is a privately held company that develops, manufactures,

More information

Dräger Savina Sub-Acute Care Ventilation

Dräger Savina Sub-Acute Care Ventilation Dräger Savina Sub-Acute Care Ventilation Maintain high standards of ventilation therapy for adult and paediatric patients of all acuity levels, even in challenging environments. MT-0030-2008 02 Dräger

More information

NEONATAL/INFANT VENTILATOR

NEONATAL/INFANT VENTILATOR n a!! i le ion b a a i l ve r s v w a lone o N d-a n sta FEATURES: MDES F VENTILATIN PRESSURE LIMITED/ CNTINUUS FLW FLW TRIGGERED VLUME VENTILATIN NENATAL/INFANT VENTILATR The Crossvent 2i+ ventilator

More information

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products Saturn Evo SATURN EVO COLOR A N A E S T H E S I A S Y S T E M i n t e l l i g e n t s i m p l i c i t y Manufacturer of high quality anaesthesia products SATURN EVO COLOR PATIENT SAFETY AND USER PATIENT

More information

fabian HFO Our 4-in-1 device

fabian HFO Our 4-in-1 device fabian HFO Our 4-in-1 device Ventilation Beyond Limits When It Comes to Life, There Is No Compromise Distributing worldwide ACUTRONIC is a privately held company that develops, manufactures, and distributes

More information

The anaesthesia workstation focused on you

The anaesthesia workstation focused on you by The anaesthesia workstation focused on you With the most advanced anaesthesia Accuracy and performance Equipped with the most advanced ventilation modes. Electronic rotameters with precise mass-flow

More information

The centerpiece of a comprehensive anaesthesia workstation

The centerpiece of a comprehensive anaesthesia workstation The centerpiece of a comprehensive anaesthesia workstation IntelliSave AX700 anaesthesia machine A slim design with rich functionality The IntelliSave AX700 is a comprehensive anaesthesia machine from

More information

State-of-the-art anesthesia technology

State-of-the-art anesthesia technology State-of-the-art anesthesia technology anesthesia system Get closer to the MRI scanner Superb certified performance in close proximity to strong magnetic fields. Our innovative machine provides benefits

More information

AUGUST ANESTHESIA MACHINES MEDICAL PRODUCTS ANESTHESIA MACHINES. Quality System Standard applied: ISO 9001, ISO 13485

AUGUST ANESTHESIA MACHINES MEDICAL PRODUCTS ANESTHESIA MACHINES. Quality System Standard applied: ISO 9001, ISO 13485 ANESTHESIA MACHINES AUGUST - 2008 MEDICAL PRODUCTS ANESTHESIA MACHINES Quality System Standard applied: ISO 9001, ISO 13485 CE Certification 93/42/EEC. Arsiconsult 38, Av. Guy de Maupassant 78400 Chatou

More information

Oxylog 3000 plus Emergency & Transport Ventilation

Oxylog 3000 plus Emergency & Transport Ventilation Oxylog 3000 plus Emergency & Transport Ventilation Offering high ventilation performance with features such as AutoFlow, integrated capnography and non-invasive Ventilation, the compact and robust Oxylog

More information

Automatic Transport Ventilator

Automatic Transport Ventilator Automatic Transport Ventilator David M. Landsberg, MD, FACP, FCCP, EMT-P Luke J. Gasowski, RRT, NPS, ACCS, CCP-C, FP-C Christopher J. Fullagar, MD, FACEP, EMT-P Stan Goettel, MS, EMT-P Author credits /

More information

Your patients, our primary focus. Siesta i Whispa anesthesia machine

Your patients, our primary focus. Siesta i Whispa anesthesia machine Your patients, our primary focus Siesta i Whispa anesthesia machine Functional, and flexible At Dameca we are not just committed to meeting the healthcare needs of today. We also think about tomorrow.

More information

SERVO-s v8.0 Data sheet

SERVO-s v8.0 Data sheet Data sheet This document is intended to provide information to an international audience outside of the US. 2 Critical Care Key features For adult and pediatric patients A ventilator system designed to

More information

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES DATA ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES CRITICAL CARE HIGHLIGHTS! For all patient categories, from neonate and pediatric to adult! A platform for the future choose the level of system

More information

SLE5000 Neonatal Ventilator with High Frequency Oscillation

SLE5000 Neonatal Ventilator with High Frequency Oscillation SLE5000 Neonatal Ventilator with High Frequency Oscillation The SLE5000 is superb: the best High Frequency Ventilator I ve used When the smallest thing matters SLE5000 - The Total Solution for Infant Ventilation

More information

DATA SHEET. VENTILATION SERVO-s

DATA SHEET. VENTILATION SERVO-s DATA SHEET VENTILATION The Gold Standard Critical Care 3 PROVEN SERVO SIMPLICITY, RELIABILITY AND SENSITIVITY MAQUET THE GOLD STANDARD Leading the way: MAQUET is a premier international provider of medical

More information

Anesthesia Workstation

Anesthesia Workstation Your healthcare, we care. A9800 Anesthesia Workstation Technical Parameters A9800 Ventilation Modes Alarms Volume Control Pressure Control SIMV with Pressure Support (SIMV + PS) - with Volume or Pressure-type

More information

O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes

O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes O-Two Self-Study Guide e600 Transport Ventilator Ventilation Modes e600 VENTILATION MODES The e600 ventilator has 13 ventilation modes: Manual Ventilation, Controlled Mandatory Ventilation (CMV), Assist

More information

IEC C LASSIFICATIONS:

IEC C LASSIFICATIONS: Enrich life Introducing Astral Introducing the Astral 100 and Astral 150 life support ventilators. From initial setup to everyday use, Astral offers greater freedom, confident care and designed efficiency

More information

Intensa GO Alternate Care Ventilator

Intensa GO Alternate Care Ventilator EN Intensa GO Alternate Care Ventilator 0197 Intensa GO Versatility and simplicity The all new WILAmed Ventilator INTENSA Go offers great versatility and simplicity. It is designed to ventilate (invasive

More information

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring The Dräger Savina 300 Select combines the independence and power of a turbine-driven ventilation system with sofisticated ventilation

More information

INTENDED USE CLASSIFICATION PHYSICAL CHARACTERISTICS

INTENDED USE CLASSIFICATION PHYSICAL CHARACTERISTICS INTENDED USE The GraphNet ts ventilator was designed to be used with all types of patients: adult, pediatric, and neonatal infants (optionally with the NEO-INF module) requiring invasive and noninvasive

More information

fabian HFO: Modular, Powerful, Versatile.

fabian HFO: Modular, Powerful, Versatile. fabian HFO: Modular, Powerful, Versatile. Introducing the flagship of the ACUTRONIC FABIAN FAMILY. The FABIAN HFO, a ventilator developed specifically for the NICU and PICU needs, packed with many great

More information

The anaesthesia workstation focused on you

The anaesthesia workstation focused on you by The anaesthesia workstation focused on you The anaesthesia Accuracy and performance Equipped with the most advanced ventilation modes. Electronic rotameters with precise mass-flow sensors, allowing

More information

APUS Anesthesia Machines

APUS Anesthesia Machines APUS Anesthesia Machines APUS x1 Anesthesia Machine Breathing circuit applicable for complete range Autoclavable metal and plastic materials. Suitable for adult, pediatric and neonatal patients. Featured

More information

Dräger Savina 300 Classic ICU Ventilation and Respiratory Monitoring

Dräger Savina 300 Classic ICU Ventilation and Respiratory Monitoring Dräger Savina 300 Classic ICU Ventilation and Respiratory Monitoring The Dräger Savina 300 Classic (in this configuration) combines the independence and power of a turbine-driven ventilation system with

More information

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Fabius Tiro TM Designed for your environment Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Traditional hospital ORs have their needs... With more surgical procedures being performed

More information

Operation and Maintenance of the EPV200 Portable Ventilator

Operation and Maintenance of the EPV200 Portable Ventilator Operation and Maintenance of the EPV200 Portable Ventilator 1 Applications of the EPV200 The EPV200 Portable Ventilator is a gas powered electronically controlled mechanical ventilator, designed to provide

More information

Flight Medical presents the F60

Flight Medical presents the F60 Flight Medical presents the F60 Reliable Ventilation Across the Spectrum of Care Adult & Pediatric Pressure/Volume Control Basic/Advanced Modes Invasive/NIV High Pressure/Low Flow O2 Up to 12 hours batteries

More information

Understanding and comparing modes of ventilation

Understanding and comparing modes of ventilation Understanding and comparing modes of ventilation Löwenstein Medical GmbH & Co. KG Content Volume-Controlled Ventilation Modes VCV PLV VC-SIMV Optional VCV Flexible VCV Pressure-Controlled Ventilation Modes

More information

HAMILTON-G5. The modular high-end ventilation solution

HAMILTON-G5. The modular high-end ventilation solution HAMILTON-G5 The modular high-end ventilation solution We live for ventilation technology We live for ventilation technology. Technology that helps caregivers improve the lives of their critically ill patients.

More information

ekom Compressor for Medical Air Sonata with Ekom

ekom Compressor for Medical Air Sonata with Ekom Compressor for Medical Air The compressor A40 is an ideal accessory for the intensive ventilators elisa and sonata. The A40 can be used either as the main or as a back-up gas supply. In the event of a

More information

Dameca MRI 508. State-of-the-art MRI technology

Dameca MRI 508. State-of-the-art MRI technology Dameca MRI 508 State-of-the-art MRI technology The closer, the safer the better Hospitals have long awaited an anaesthesia machine that can be used close to their MRI scanner. The Dameca MRI 508 is it

More information

An intuitive and innovative answer to your anaesthesia challenges

An intuitive and innovative answer to your anaesthesia challenges An intuitive and innovative answer to your anaesthesia challenges Dameca AX500 anaesthesia machine Meeting your needs today and tomorrow As an expert in anaesthesia care, you are looking to continuously

More information

D Beyond essentials DRÄGER SAVINA 300 SELECT

D Beyond essentials DRÄGER SAVINA 300 SELECT D-13420-2016 Beyond essentials DRÄGER SAVINA 300 SELECT 2 D-12039-2016 D-11112-2010 The best possible patient care is your focus every day. That s why you need a ventilator you can rely on, in any situation.

More information

Technical Specifications

Technical Specifications Technical Specifications 2 The appropriate device for every application. The bellavista model 1000 is available in two separate basic versions in order to accommodate varying ventilator applications bellavista

More information

HAMILTON-C2 HAMILTON-C2. The universal ventilation solution

HAMILTON-C2 HAMILTON-C2. The universal ventilation solution HAMILTON-C2 HAMILTON-C2 The universal ventilation solution The universal ventilation solution HAMILTON-C2 - The compact ventilation solution The HAMILTON-C2 mechanical ventilator is a universal ventilation

More information

MEDICAL EQUIPMENT IV MECHANICAL VENTILATORS. Prof. Yasser Mostafa Kadah

MEDICAL EQUIPMENT IV MECHANICAL VENTILATORS. Prof. Yasser Mostafa Kadah MEDICAL EQUIPMENT IV - 2013 MECHANICAL VENTILATORS Prof. Yasser Mostafa Kadah Mechanical Ventilator A ventilator is a machine, a system of related elements designed to alter, transmit, and direct energy

More information

SERVO-air ventilator. Datasheet for system version 2.1

SERVO-air ventilator. Datasheet for system version 2.1 SERV-air ventilator Datasheet for system version 2.1 This document is intended to provide information to an international audience outside of the US. Contents Technical specifications... 3 General... 3

More information

Inspiration 7i Ventilator

Inspiration 7i Ventilator Inspiration 7i Ventilator Clinician Focused Products is not just a tag line, rather a belief system. Low cost of ownership High performance PSOL and active exhalation Comprehensive graphics and trending

More information

Software enhancements

Software enhancements ADDENDUM Software enhancements Introduction.......................................... 1 Update to patient circuit ranges........................... 4 Patient circuit type selection............................

More information

HAMILTON-C1 neo. Technical specifications

HAMILTON-C1 neo. Technical specifications HAMILTON-C1 neo HAMILTON-C1 neo Technical specifications The HAMILTON-C1 neo is a versatile ventilator that combines invasive and noninvasive modes* with additional options of ncpap and high flow oxygen

More information

Mechanical Ventilation. Mechanical Ventilation is a Drug!!! is a drug. MV: Indications for use. MV as a Drug: Outline. MV: Indications for use

Mechanical Ventilation. Mechanical Ventilation is a Drug!!! is a drug. MV: Indications for use. MV as a Drug: Outline. MV: Indications for use Mechanical Ventilation is a Drug!!! Mechanical Ventilation is a drug I am an employee of Philips Healthcare Hospital Respiratory Care Group and they help me pay for my kids education Jim Laging, RRT, RCP

More information

Monnal T60. Touch and Breathe.

Monnal T60. Touch and Breathe. Monnal T60 Touch and Breathe www.airliquidemedicalsystems.com Close to the emergency Monnal T60 has been designed for mobile medical intervention in all intensive care environments, both inside and outside

More information

Operator s Manual Addendum

Operator s Manual Addendum Software Enhancements Table of Contents Introduction.............................................. 1 Update to patient circuit ranges............................... 4 Patient circuit type selection................................

More information

Introducing Astral. Greater freedom. Confident care. Designed efficiency

Introducing Astral. Greater freedom. Confident care. Designed efficiency Enrich life Introducing Astral From initial setup to everyday use, the Astral 100 and Astral 150 life support ventilators offer greater freedom, confident care and designed efficiency to enrich life for

More information

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features)

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features) The Crossvent 2i+ 1. How is this ventilator classified 2. Ventilator Concept (brief theory of operation and features) -Your Two Choices with this Ventilator 3. An overview of the device (an in-service)

More information

Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life

Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life D-9355-2009 Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM Dräger. Technology for Life 02 DRÄGER FABIUS GS PREMIUM One of the most challenging places D-9354-2009 on earth The modern hospital

More information

Blease900 Ventilator PATIENT CENTERED VENTILATION

Blease900 Ventilator PATIENT CENTERED VENTILATION Blease900 Ventilator PATIENT CENTERED VENTILATIN PATIENT CENTERED VENTILATIN From the first Blease/Manley ventilator sixty years ago, Spacelabs Healthcare has built a heritage of innovative and intuitive

More information

Your patients, our primary focus

Your patients, our primary focus Your patients, our primary focus Siesta i Whispa anesthesia machine Functional, fail-safe and flexible to your needs Take a good look, and you ll be surprised by the many forward-thinking features of the

More information

D Beyond essentials DRÄGER SAVINA 300 SELECT

D Beyond essentials DRÄGER SAVINA 300 SELECT D-13420-2016 Beyond essentials DRÄGER SAVINA 300 SELECT D-11112-2010 D-12039-2016 2 D-13512-2016 The best possible patient care is your focus every day. That s why you need a ventilator you can rely on,

More information

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring The Dräger Savina 300 Select (in this configuration) combines the independence and power of a turbine-driven ventilation system with

More information

Selecting the Ventilator and the Mode. Chapter 6

Selecting the Ventilator and the Mode. Chapter 6 Selecting the Ventilator and the Mode Chapter 6 Criteria for Ventilator Selection Why does the patient need ventilatory support? Does the ventilation problem require a special mode? What therapeutic goals

More information

EvitaXL. Excellence throughout the ventilation process. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

EvitaXL. Excellence throughout the ventilation process. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care EvitaXL Excellence throughout the ventilation process Emergency Care Perioperative Care Critical Care Perinatal Care Home Care EvitaXL is there At the bedside and throughout the hospital Ventilated patients

More information

Siesta i Whispa Integrated technology

Siesta i Whispa Integrated technology Siesta i Whispa Integrated technology Functional, fail-safe and flexible to your needs Take a good look, and you ll be surprised by the many forward-thinking features of the Siesta i Whispa anaesthesia

More information

Emergency Transport and Ventilation

Emergency Transport and Ventilation Emergency Transport and Ventilation When you get a call and the patient is not breathing, are you and your equipment ready? Can you make the difference? Pneupac portable gas powered ventilators (PGPVs)

More information

VENTILATION SERVO-i INSPIRATION IN EVERY BREATH

VENTILATION SERVO-i INSPIRATION IN EVERY BREATH VENTILATION SERVO-i INSPIRATION IN EVERY BREATH The Gold Standard Critical Care SERVO-i 3 PROVIDING THE HIGHEST LEVEL OF CLINICAL CARE MAQUET THE GOLD STANDARD Leading the way: MAQUET is a premier international

More information

D Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS

D Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS D-33257-2011 Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS 02 Rising up to the challenge D-33317-2011 D-33494-2011 D-33299-2011 ICU ventilation standard at all times Whether you re in

More information

Mechanical Ventilation

Mechanical Ventilation Mechanical Ventilation Understanding Modes Rob Chatburn, RRT-NPS, FAARC Research Manager Respiratory Therapy Cleveland Clinic Associate Professor Case Western Reserve University 1 Overview Characteristics

More information

Specification of ICU Ventilator (Respiratory Ventilator

Specification of ICU Ventilator (Respiratory Ventilator Specification of ICU Ventilator (Respiratory Ventilator 1. Should have facility for Invasive and Non-Invasive ventilation. 2. Microprocessor Control suitable for Pediatric and adult ventilation. 3. Electromagnetic

More information

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring The Dräger Savina 300 Select (in this configuration) combines the independence and power of a turbine-driven ventilation system with

More information

No./DMER/Tender Notice/Equip.Pur/16-17/Corri.(10)/7M Date :- 03/09/2016

No./DMER/Tender Notice/Equip.Pur/16-17/Corri.(10)/7M Date :- 03/09/2016 No./DMER/Tender Notice/Equip.Pur/16-17/Corri.(10)/7M Date :- 03/09/2016 E-Tender Notice CORRIGENDUM REGARDING SPECIFICATIONS FOR 1. EQ-C-256/16-17 SyringePump/Infusion Pump 2. EQ-C-257/16-17 Video Gastroscope

More information

Peter Kremeier, Christian Woll. 2nd. Understanding and comparing modes of ventilation. The Kronberg List of Ventilation Modes

Peter Kremeier, Christian Woll. 2nd. Understanding and comparing modes of ventilation. The Kronberg List of Ventilation Modes Extended Edition Revised and 2nd Peter Kremeier, Christian Woll Understanding and comparing modes of ventilation The Kronberg List of Ventilation Modes Contents Preface... 3 Comparison Table - Parameters...6

More information

Supporting you in saving lives!

Supporting you in saving lives! Minimum size maximum performance www.hamilton-medical.com/c1 Supporting you in saving lives! HAMILTON-C1 ventilators bring powerful features in a compact design that increases the availability of appropriate

More information

Biomedical Equipment for Indoor Section

Biomedical Equipment for Indoor Section KASTURBA HEALTH SOCIETY'S MAHATMA GANDHI INSTITUTE OF MEDICAL SCIENCES, P.O. SEVAGRAM, WARDHA (DISTT.) MAHARASHTRA STATE - 442 102 Specifications Biomedical Equipment for Indoor Section 1) Mechanical Ventilator

More information

CPAP Devices - Masks - Accessories for respiratory assistance in CPAP

CPAP Devices - Masks - Accessories for respiratory assistance in CPAP Devices - Masks - Accessories for respiratory assistance in HAROL is one of the Italian companies leader in developing and selling systems, determining the most appropriate solutions for all your needs.

More information

Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

Automatic Transport Ventilators. ICU Quality Ventilation on the Street. Automatic Transport Ventilators ICU Quality Ventilation on the Street. Kevin Bowden, March 20 th 2014 Ventilator Definition A ventilator is an automatic mechanical device designed to provide all or part

More information

ihope Series Ventilator Nov. 2017

ihope Series Ventilator Nov. 2017 ihope Series Ventilator Nov. 2017 ihope RS Series Super specialist in NIV Advisedly design on ihope series for all critical juncture ihope series is new state of art design in critical care ventilation

More information

Hospital and Transport for Controlled Breathing

Hospital and Transport for Controlled Breathing Hospital and Transport for led Breathing When transporting a critically ill patient you need a ventilator that can go anywhere in any situation. Smiths Medical Pneupac small portable gas powered ventilators

More information

Pre-Bid Minutes for E-193 Ventilator Dt

Pre-Bid Minutes for E-193 Ventilator Dt Pre-Bid Minutes for E-193 Ventilator Dt. 21.07.2014 Sr. 1 2 3 4 5 E-193 Ventilator M/s. Drag India Pvt. Ltd. M/s. Drag India Pvt. Ltd. M/s. Drag India Pvt. Ltd. M/s. Drag India Pvt. Ltd. M/s. Hamilton

More information

Fabius Tiro TM. Designed for your environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Fabius Tiro TM. Designed for your environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Fabius Tiro TM Designed for your environment Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Because you care Traditional hospital ORs have their needs... With more surgical procedures

More information

Patient Setup Information

Patient Setup Information VOCSN Out of Box Tips For temporary use before entering patient settings, VOCSN can be configured as follows to help ease the setup process: 1 Remove VOCSN from its shipping packaging. 2 Attach the circuit.

More information

MEDUMAT Standard a MEDUMAT Standard. The Ventilation Standard for Professionals

MEDUMAT Standard a MEDUMAT Standard. The Ventilation Standard for Professionals a The Ventilation Standard for Professionals a The Ventilation Standard for Professionals a offers you everything you need for reliable emergency ventilation. Users around the world are impressed by its

More information

Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS

Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS D-33257-2011 Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS 2 Rising up to the challenge D-33317-2011 D-33494-2011 D-33299-2011 ICU ventilation standard at all times Whether you re in

More information

Supporting your patients every breath

Supporting your patients every breath Supporting your patients every breath ResMed.com/Astral Stay informed of patient changes throughout the therapy journey Improve patient care through connectivity. Astral s connectivity to AirView gives

More information

Oxylog VE300 Emergency & Transport Ventilation

Oxylog VE300 Emergency & Transport Ventilation Oxylog VE300 Emergency & Transport Ventilation The straightforward and user-friendly Dräger Oxylog VE300 is built to face your challenges in preclinical emergency services With reliable ventilation technology,

More information