Gas Mixing System (GMS)
|
|
- Priscilla Hopkins
- 1 years ago
- Views:
Transcription
1 Gas Mixing System (GMS) Installation and Operation Manual Version: (September 12, 2017)
2 ii Disclaimer The information in this publication is provided for reference only. Every effort has been made to make this manual as complete and as accurate as possible. However, in no event shall the publisher and author of this document be liable for errors contained herein nor for incidental or consequential damages or injuries in connection with the furnishing, performance or use of this material. All product specifications, as well as the information contained in this publication, are subject to change without notice. This publication may contain or reference information and products protected by copyrights or patents and does not convey any license under our patent rights, nor the rights of others. We do not assume any liability arising out of any infringements of patents or other rights of third parties. We make no warranty of any kind with regard to this material, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Customers are ultimately responsible for validation of their systems Loligo Systems ApS. All rights reserved. No part of this publication may be stored in a retrieval system, transmitted, or reproduced in any way, including but not limited to photocopy, photograph, magnetic or other record, without our prior written permission. BOBS is a registered trademark of Loligo Systems All rights reserved. All trademarks within are the property of their respective owners.
3 iii Technical Support Loligo Systems ApS Toldboden 3, 2nd floor DK-8800 Viborg Denmark Phone
4 iv Safety notes Please follow these safety guidelines to protect yourself from potential hazards. Please note that this list is not exhaustive and careful handling of the device is required at all times. Loligo Systems is not liable for any injuries arising from inappropriate operation of the device. Please follow these general guidelines: Read all instructions prior to installing, operating and servicing this product Install your equipment as specified in the instruction manual. The GMS must not be installed and operated by unqualified personnel. Connect the product to the specified electrical, gas and pressure sources. Ensure that all power cables and gas tubing are in proper condition and securely connected. Disconnect all power sources when maintenance is being performed, to prevent electrical shock and personal injury. Do not operate this instrument in excess of the specifications marked on and supplied with this product. Failure to heed this warning can result in serious personal injury and/or damage to the equipment. Do not operate the GMS with gases other than oxygen, nitrogen and carbon dioxide to avoid risk to health and damage of the device Only use the GMS in well aerated spaces to avoid depletion of oxygen or harmful levels of carbon dioxide. Do not use the product if it is damaged or defective. References should always be made to the Health and Safety data supplied with any chemicals used. Generally accepted laboratory procedures for safe handling of chemicals should be employed.
5 v Symbols Follow all CAUTION and WARNING notes marked on and supplied with this product to avoid serious injury or damage to the device. Symbol Meaning A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met. Danger from electrical voltage. Failure to head this warning may lead to serious injury or death. Information about any essential requirements or actions to operate the instrument. Helpful information that may improve the usability of the instrument. CE mark indicating that the product has been assessed to meet safety and health requirements for products sold in the EEA. According to the directive 2002/96/EG (WEEE), any product labelled with this WEEE symbol must not be disposed of with the domestic waste.
6 vi Intended use of the product The Loligo Systems Gas Mixing System (GMS) is a scientific instrument and exclusively designed to mix oxygen (O 2 ), carbon dioxide (CO 2 ) and nitrogen (N 2 ) gas in research laboratories. Only use gases and apply chemicals with the GMS as specified in Table 1. Loligo Systems will not be liable for any use of gases and chemicals not contained therein. Table 1: Use and application of chemicals approved for the GMS. Chemical/Agent Deionized water Ethanol N 2 gas O 2 gas CO 2 gas Application Cleaning, gas humidification Cleaning Gas mixing The GMS instruments may not be retrofitted by users. Only original parts and accessories as well as pressure rated tubing and connectors must be used for operation and maintenance the GMS instruments. Do not operate the GMS in damp and wet areas or outdoors. The GMS is not designed for medical applications. Any other use as specified in this manual is not permitted.
7 vii Table of Contents DISCLAIMER... II TECHNICAL SUPPORT... III SAFETY NOTES... IV SYMBOLS... V INTENDED USE OF THE PRODUCT... VI TABLE OF CONTENTS... VII TABLE OF FIGURES... IX 1 INTRODUCTION PRODUCT OVERVIEW INSTRUMENT SPECIFICATIONS SHIPMENT COMPONENTS INSTALLATION SYSTEM REQUIREMENTS SOFTWARE Overview Installation Settings HARDWARE Overview GMS installation EXPERIMENT OVERVIEW RUNNING AN EXPERIMENT Choose experiment mode End of experiment TROUBLESHOOTING APPENDIX MAINTENANCE Cleaning Change of fuse... 14
8 viii Calibration service GMS WARRANTY Warranty policy Limitation of Warranty Limitation of Remedies: DISPOSAL DECLARATION OF CONFORMITY INDEX... 17
9 ix Table of Figures Figure 1: GMS rear view... 1 Figure 2: GMS & accessories Figure 3: Software settings Figure 4. Rear of the GMS Figure 5: Experiment overview... 8 Figure 6: Experiment checklist... 9 Figure 7: Manual mode Figure 8: Experiment summary Figure 9: Automated experiment Figure 10: Automated protocol Figure 11: Automated experiment Figure 12: Change of fuse
10 Introduction 1 1 Introduction 1.1 Product overview The Gas Mixing System (GMS) by Loligo Systems performs automated fine-scale mixing of oxygen (O 2 ), carbon dioxide (CO 2 ) and nitrogen (N 2 ) gas using in-built mass flow controllers. The GMS can be readily connected and operated with the Loligo Systems Blood Oxygen Binding System (BOBS ) or customized to any other application, which requires precise mixing of gases. Features Broad and fine-scaled range of O 2 mixtures (0.01% - 100%) CO 2 mixing from 0.03% to 6% Software controlled automated gas mixing Customizable to different gas ranges and gas types Figure 1: GMS rear view
11 Introduction Instrument specifications Type gas flow controller Recommended input pressure* Maximum input pressure Brooks Instruments SLA5850 Rev B Mass Flow Controller 2 bar (± 0.3 bar) 2.5 bar Permitted gas types** N 2, O 2, CO 2 Gas ranges O %, CO % Gas connector type Maximum flow rate*** 6 mm push-in O 2 : 500 ml / min N 2 : 500 ml / min CO 2 : 15 ml / min Communication interface USB 2.0 Flow Accuracy**** Repeatability & Reproducibility Response Time Zero stability Power supply Dimensions Weight ±0.9% of set point (S.P.) (20-100% F.S.), ±0.18% of F.S. (2-20% F.S., 1-20% F.S. from 1-50 lpm) 0.20% S.P. 2 s < ± 0.2% F.S. per year VAC 50/60Hz Height 194 mm, Width 199 mm, Depth 227 mm 11 kg Operating temperature C ( F) *Other input pressures may lead to inaccurate gas mixing **Other gas types on request ***Other flow rates on request **** Flow accuracy N 2 equivalent typical
12 Introduction Shipment components Please check for completeness of the listed components when unpacking. Figure 2: GMS & accessories. Gas mixing system Power cable USB cable USB stick with GMS software and product documentation Two meters 6 mm PU tubing T-piece push-in fitting 3 x push-in hose adapter 4 mm 3 x push-in hose adapter 6 mm
13 Installation 4 2 Installation This chapter outlines how to perform the initial set-up of the GMS software and hardware. 2.1 System requirements One free USB ports on your PC Windows 7 or higher PC with minimum Pentium IV processor of 2,4 GHz and 4GB RAM or better Recommended monitor resolution of 1024x768 pixels 2.2 Software Overview The GMS can be operated as standalone device using the GMS software or as part of the Loligo System`s Blood Oxygen Binding Systems (BOBS ) using the BOBS software (for details see BOBS manual). Both software enable automated and customizable gas mixing experiments. The software setup installs all drivers und the user interface required to operate the GMS Installation To install the GMS software you need to be logged in as administrator or start the installation as administrator. 1. Turn on the PC. 2. Verify that the monitor display is set to a minimum of 1024 x Insert the supplied USB stick into a USB port of your PC. 4. Open the folder of the USB stick. 5. Go to the GMS folder and double-click on GMS.exe. If not logged in as administrator right-click on GMS.exe and select `Run as administrator` from the pop-up menu. 6. Setup now guides you through the installation procedure. Follow the on-screen instructions as they appear.
14 Installation 5 7. After installation is complete restart your PC Settings 1. Double-click on the GMS icon on your desktop. 2. Go to Settings (Figure 3) 3. Adjust the user interface to your preferred graph background or language. Figure 3: Software settings. The GMS software identifies the COM ports allocated to the in-built mass flow controllers automatically. However, communication may fail if two digit COM ports were allocated by Windows. In this case, change the GMS COM ports to one digit numbers in the Windows device manager. 2.3 Hardware Overview Please follow these instructions to connect the GMS to your PC GMS installation You must install the GMS software prior to connecting the GMS to the PC.
15 Installation 6 The GMS weighs 11kg. Please consult help from another person if you are unable to safely lift the device alone. Only install and operate the GMS in well aerated spaces to avoid depletion of O 2 or harmful levels of CO Unpack the GMS and place the device safely on an even and stable surface. Leave approximately 20 cm space at each site to allow for sufficient air circulation at the ventilation slots. Keep the packaging for future transport. 2. Connecting the GMS with gas supplies a. Cut the 6 mm tubing to the required length. b. Push the 6 mm tubing into one of the blue fittings at the rear of the GMS (Figure 4). c. Connect the other end of the tubing to the corresponding gas supply as indicated by the gas type label (Figure 4). d. To connect O 2 gas you may branch the O 2 gas supply into two tubes using the supplied T-piece. The two ends are then connected to the two O 2 gas fittings at the rear of the GMS (Figure 4). Figure 4. Rear of the GMS.
16 Installation 7 Only connect O 2, N 2 and CO 2 gas supplies to the GMS. 3. Connect one end of the provided 6 mm tubing with the orange push-in fitting located at the top-rear of the GMS labelled as `GAS OUT (Figure 4) and the other end with the gas input port of your experimental device. 4. Connect the provided power cable first to the rear of the device and then to a VAC 50/60 Hz power supply. To avoid electrical shock, use a grounded receptacle. Do not connect the GMS to AC power mains without an earthed ground connection. Always connect the AC power cable to the device first and then to the power source. Operation at AC input levels outside of the specified operating voltage range may damage the GMS. 5. Connect the supplied USB cable between the USB port at the rear of the GMS with the USB port of your PC. 6. Check if all tubing is connected tightly and safely. Do not turn on the gas supply until you are certain that all tubing and gas connections are fitted tightly. Failure to heed this warning can result in serious personal injury. 7. Turn the pressure regulator of all gas sources to the lowest level. Then, open the gas supply and slowly increase the pressure till you reach 2 bar for all three gas types. Carefully evaluate tubing and connections for any gas leaks. The GMS will only operate accurately if the input pressure matches the specified calibration pressure of 2 bar. Do not exceed the specified maximum input pressure of 2.5 bar as this may result in serious personal injury and damage to the device. 8. Switch on the red power button at the rear of the GMS. 9. Start the GMS software. 10. The GMS is now ready to use.
17 Experiment 8 3 Experiment 3.1 Overview Title bar Tool bar Graph The title bar displays the experimental time and an arrow to return to the main menu. The tool bar contains a gas unit selector and a STOP EXPERIMENT button to terminate the experiment. The graph window displays the setpoints and actual percentage/flow readings of all three gas types. Graph legend Gas settings Data The graph legend explains the symbols and lines of the current graph display. It further displays data values that are currently selected by the vertical selection bar, which appears when you move over the graph. The display of data can activated/deactivated by clicking on the check mark adjacent to the corresponding data type. In the gas settings, concentration/flow of O 2 and CO 2 can be changed. Under data, concentration and flow of gases are displayed. Figure 5: Experiment overview.
18 Experiment Running an experiment Choose experiment mode 1. Start the GMS software 2. Click on `Experiment 3. In the Experiment checklist choose `Manual or `Automated experiment type from the drop down field (1, Figure 6). 4. Choose a location for the log file to be saved (2, Figure 6). 5. START the experiment (3, Figure 6) Figure 6: Experiment checklist Manual Choose this option if you want flexibility and be able to change gas concentrations manually during the experiment. This mode is most appropriate for establishing new protocols. Afterwards, the settings may then be transferred to the automated protocol. 1. Select a gas unit (1, Figure 7). 2. Set the O 2 concentration/flow in the gas setpoints field (2, Figure 7). 3. Set the carbon dioxide concentration/flow in the gas setpoints field (3, Figure 7). 4. Stop the experiment upon completion (4, Figure 7).
19 Experiment 10 The nitrogen gas concentration is set automatically to obtain a cumulative gas concentration of 100%. Figure 7: Manual mode. 5. Choose to open or save the log file (1, Figure 8) and return to the main menu by clicking on the arrow (2). Figure 8: Experiment summary. Automated
20 Experiment 11 This mode combines flexibility with automation. You can upload your own customized protocol, which the GMS software will run automatically. This mode is most appropriate for established experiments that do not fit the standard protocol. 1. In the Experiment checklist choose `Automated experiment type from the drop down field (1, Figure 9). Figure 9: Automated experiment 2. Select an automated protocol (2). You can create an automated protocol in a standard spread sheet software according to the format in Figure 10, saved as tab delimited txt file. Figure 10: Automated protocol. 3. Choose a location for the log file to be saved (2, Figure 9).
21 Experiment START the experiment (3, Figure 9). 5. The experiment will now run and terminate automatically according to the automated protocol. The timer (1, Figure 11) displays the remaining time for each step and the whole experiment. You may also abort the experiment before automatic completion (2). Figure 11: Automated experiment Once the experiment completes, all gas flows are set to zero to preserve gas supplies End of experiment 1. Once experiments are completed close the GMS software. 2. Turn off all gas supplies. 3. Switch off the GMS using the power button at the rear.
22 Troubleshooting 13 4 Troubleshooting This chapter gives advice and tips to solve problems that may occur while operating the BOBS. Symptom Cause Remedy No gas flow GMS not switched on Switch on GMS No gas flow Gas supply turned off Turn on gas supply No gas flow Gas tubing blocked Assure all tubing is connected tightly to all push-in fittings and connectors No gas flow Leaky gas connection Check for any gas leaks in tubing or connections Low gas flow Insufficient input pressure Assure input pressure of all supply gases is 2 bar GMS software runs slow or stops unexpectedly Insufficient RAM Use a PC with minimum 4 GB RAM * Always contact Loligo Systems ApS prior to shipping the instrument for service.
23 Appendix 14 5 Appendix 5.1 Maintenance Cleaning Use a moist cloth to clean the surfaces of the GMS device. Only use water, ethanol, non-aggressive, non-corrosive and non-abrasive cleaning agents for cleaning. Do not use solvents. Disconnect the GMS from the AC power source before cleaning. Do not wet electrical contacts. Failure to head this warning may lead to death or serious injury Change of fuse The GMS is secured with a fuse to protect the device from high currents. Follow these steps to replace the fuse if blown. 1. Disconnect the power cord at the rear of the GMS. Always disconnect the GMS from the AC power source during any maintenance work. Failure to head this warning may lead to death or serious injury. 2. Carefully lift up the fuse holder using a slotted electrical screw driver (Figure 12A). Figure 12: Change of fuse. 3. Replace the blown fuse with a new one with the exact power rating as specified on the fuse label below (Figure 12B). 4. Replug the fuse holder into the power socket with the plastic clip facing right (Figure 12C).
24 Appendix 15 The use of fuses with power ratings other than specified may damage the device and will void the warranty Calibration service GMS To assure continued accuracy of the GMS we recommend to re-calibrate the GMS every 1-3 years (depending on the frequency of use) using Loligo Systems` gas flow meters or by returning the instrument to Loligo Systems. 5.2 Warranty Warranty policy We offer a 2 year warranty against defects in material or workmanship from date of purchase. If a problem develops during that period, please contact Loligo Systems with a detailed description. If the problem cannot be solved at a distance, we will issue you with a Return of Materials Authorization number (RMA). Loligo Systems cannot accept responsibility for goods returned without an RMA number. Contact Loligo Systems prior to shipping the product to arrange shipping, payment and documentation. Loligo Systems will at its discretion repair or replace the instrument. The warranty specifically excludes damages caused by misuse, abuse or unauthorized modifications or repairs Limitation of Warranty In no event shall Loligo Systems be responsible for any damages suffered by buyer arising out of buyer s own negligence or willful acts or failure to act in connection with the storage, handling or use of Loligo Systems Instruments by buyer or its transferee of risk of loss or damage thereto. After the warranty period has expired Loligo Systems offers a repair, update, and retro-fit service at a fee Limitation of Remedies: Loligo Systems shall not be liable under any circumstances for any special, consequential, incidental, punitive or exemplary damages arising out of or in any way connected with this agreement to sell goods to buyer of the goods, including, but not limited to, damages for lost profits, loss of use, lost data, or for any damages or sums paid by buyer to third parties, even if Loligo Systems has been advised of the possibility of such damages. The foregoing limitation of liability shall apply whether the claim is based upon principles of contract, warranty, negligence, or other tort, breach of any statutory duty, principles of indemnity or contribution, the failure of any limited or exclusive remedy to achieve its essential purpose, or otherwise.
25 Appendix Disposal Before disposal, the device must be decontaminated and cleaned to protect people, the environment and property. Always observe the statutory requirements when disposing the product. According to the directive 2002/96/EG (WEEE), any devices supplied after August 13, 2005, to the business-to-business area this product is assigned to, must not be disposed of with the domestic waste. Because disposal regulations may differ from one country to another, please contact your supplier if necessary. This symbol of the crossed out garbage bin points out that the unit must not be disposed of with the domestic waste.
26 Appendix Declaration of Conformity
27 Index 18 6 Index C Calibration service Cleaning Components... 2 D Declaration of Conformity Disposal E Experiment Experiment mode... 9 Running an experiment... 9 F Fuse I Installation Hardware... 5 Software... 4 Instrument overview... 1 Instrument specifications... 2 M Maintenance S Safety notes... iv Safety symbols... v Settings... 5 System requirements... 4 T Technical support... iii Troubleshooting W Warranty... 15
Model SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA
Calibration Guide Model SM/PL Series Precision Loads Anritsu Company 490 Jarvis Drive Morgan Hill, CA 95037-2809 USA Part Number: 10100-00056 Revision: B Published: January 2010 Copyright 2009-2010 Anritsu
PPS PORTABLE POWER SUPPLY
PPS User Manual Rev 1-2015 ENG MASTER PPS PORTABLE POWER SUPPLY Disclaimer About ActSafe Safety messages and warnings Product safety System description Pre-use inspection and connection General safety
MODEL 100 NITROGEN INFLATION CART
MODEL 100 NITROGEN INFLATION CART Installation & Operation Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV120106 P/N: 81-0113 TABLE OF CONTENTS SAFETY
Agilent Auxiliary Gas Module AGM 2. User s Guide
Agilent Auxiliary Gas Module AGM 2 User s Guide Notices Agilent Technologies, Inc. 1992, 1996, 1999, 2010 No part of this manual may be reproduced in any form or by any means (including electronic storage
Agilent Dimension Software for ELSD User Manual
Agilent Dimension Software for ELSD User Manual Agilent Dimension Software for ELSD User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2011 No part of this manual may be reproduced in
Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.
Advanced Calibration Designs, Inc. Calibration Gas Instrument INSTRUCTION MANUAL Release I www.goacd.com Instruction Manual Gas Generator Release I TABLE OF CONTENTS I. General Description Page 2 II. Start-Up
SDM-2012 Docking Station Standalone Configuration Operator s Manual
SDM-2012 Docking Station Standalone Configuration Operator s Manual Part Number: 71-0254RK Revision: P5 Released: 10/5/12 www.rkiinstruments.com Warranty RKI Instruments, Inc. warrants gas alarm equipment
LC-SPE. Organizer 3.0 User Manual. Innovation with Integrity. Version 001 NMR
LC-SPE Organizer 3.0 User Manual Version 001 Innovation with Integrity NMR Copyright by Bruker Corporation All rights reserved. No part of this publication may be reproduced, stored in a retrieval system,
Model AUTOMATIC UPPER ARM Blood Pressure Monitor
AUTOMATIC UPPER ARM Blood Pressure Monitor Model 1130 Real Fuzzy t e c h n o log y Features: Real Fuzzy Technology Automatic 60 sets of memory One-Touch Operation Easy-to-read Display Table of Contents:
Model ASSEMBLY and OPERATING INSTRUCTIONS
QUICK CHANGE AIR BRUSH KIT Model 93506 ASSEMBLY and OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd.,
OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument
OxyScan Graphic Operating Instructions UMS Micro-oxygen sensor 501 Microprocessor instrument Introduction Thank you for choosing the UMS Micro Oxygen Sensor 501 - a highly advanced product! Please read
PRODUCT MANUAL. Diver Smart Interface Cable AS346
PRODUCT MANUAL Diver Smart Interface Cable AS346 Contact details: Van Essen Instruments B.V. Van Essen Instruments - Canada Delftechpark 20 630 Riverbend Drive, Suite 100 2628 XH Delft Kitchener, ON, The
BGA244 Binary Gas Analyzer
Quick Start Guide Revision 1.0 Certification Warranty Service certifies that this product met its published specification at the time of shipment. This product is warranted against defects in materials
Getting to know your Sureshotgps micro V3
Getting to know your Sureshotgps micro V3 Battery State Symbol Satellite Signal Shows distance to front, centre and rear of each green Hole Number Real Time Power on and Enter Key Down (backward) Key 1
Stirring Water Bath. Instruction Manual
Stirring Water Bath Instruction Manual Catalog Nos. SWB-10L-1-110 / 220 SWB-10L-2-110 / 220 SWB-20L-1-110 / 220 SWB-20L-3-110 / 220 www.majorsci.com service@majorsci.com Version 01A October 20, 2009 Un
Pressure Relief Valve Instruction Manual
CVR3-M0_062017 Pressure Relief Valve Instruction Manual MODEL: CVR3 SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 Tel: 888-332-6419 * Fax: 816-448-2142 E-mail: sales@bvahydraulics.com Website:
E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)
Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless
USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.
USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. RECEIVING / INSPECTION Remove the Precision Medical,
AIR INLINE METAL SHEAR
AIR INLINE METAL SHEAR ASSEMBLY and OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd. / Camarillo, CA 93011 Copyright 1997 by Harbor Freight Tools. All rights reserved. No portion of this manual or any artwork
6 digital caliper with case
6 digital caliper with case Model 98563 Set up And Operating Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly
Read this first. Zetasizer nano series Self installation and Quick start guide MRK825-02
! Read this first Zetasizer nano series Self installation and Quick start guide I N S T R U M E N T S MRK825-02 Zetasizer Nano series Self installation and Quick start guide MAN0383 Issue 1.1 July 2007
AND OPERATION INSTRUCTIONS
ADI 2111-D Certified ISO 9001 MEDICAL FLOWMETER (Back Pressure Compensated Thorpe Tube) INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls
STAGE, STADIUM & X-TREME SHOT.
USER AND INSTALLATION MANUAL ENGLISH STAGE, STADIUM & X-TREME SHOT. CONFETTI & STREAMER FX PART01339 rev 01-00 DISCLAIMER WARNING Read this manual carefully before installing and/or using this product.
NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE
NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com
HoverJack. Air Patient Lift. Equipment Manual. From HoverTech International. Issued: June 1,
HoverJack Air Patient Lift From HoverTech International Equipment Manual Issued: June 1, 2008 www.hovermatt.com HOVERJACK AIR PATIENT LIFT EQUIPMENT MANUAL TABLE OF CONTENTS Instructions for Use Page 1&
453 Series Steam Heated Vaporizing Regulator
ADI 0453A Certified ISO 9001:2000 453 Series Steam Heated Vaporizing Regulator INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls Corporation
Golf Performance Monitors. PureContact Operating Guide. Version of 9
PureContact Operating Guide Version 5.1 www.zelocity.com 1 of 9 PureContact Metrics: Measured Ball Velocity Carry Distance Other PureContact Features: Instantly, Accurately Displays & Records Critical
GasLab SAN-102 Micro Oxygen Monitor User Manual
GasLab SAN-102 Micro Oxygen Monitor User Manual The GasLab SAN-102 is a wearable, personal safety meter designed to monitor ambient oxygen levels in real time. It is designed to protect workers in confined
E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information
Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.
Manual. FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator. Where Imagination Meets Innovation
FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator For inflating aircraft tires and all types of other vehicle tires and air operated devices Manual The Fresh Aero Group Where Imagination Meets
U S E R M A N U A L. Model: PM4300 Series SAVE THESE INSTRUCTIONS
U S E R M A N U A L Model: PM4300 Series (PM4351 Shown) SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090
TMP. PepperBall User Manual
TMP PepperBall User Manual WARNING THIS LAUNCHER IS NOT A TOY AND IS INTENDED FOR USE BY MILITARY, LAW ENFORCEMENT, CORRECTIONAL OFFICERS, PRIVATE SECURITY GUARDS, BAIL ENFORCEMENT AGENTS AND OTHER AUTHORIZED
Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.
FANs 216, 1628.3 Technical Bulletin CDS4000 Issue Date 0797 CDS4000 CO 2 Sensor Calibration and Troubleshooting Table of Contents Introduction 1 Handling Information 1 Calibration 2 Preparation 2 Cautions
Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems
Oxygen Concentrator Installation and Operation Manual ClearWater Tech, LLC. Integrated Ozone Systems 850-E Capitolio Way, San Luis Obispo, Ca 93401 805-549-9724 Fax: 805-549-0306 E-mail: service@cwtozone.com
USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified
USER MANUAL Model: PM4300 Series (PM4351 Shown) SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090 Northampton,
ACRYLIC FLOW METERS 0-30, 0-70 & LPM
ACRYLIC FLOW METERS 0-30, 0-70 & 0-120 LPM ASSEMBLY INSTRUCTIONS & INSTRUCTIONS FOR USE R219P86 (0-120LPM) R219P87 (0-70LPM) R219P88 (0-30 LPM) R138P11 Rev. D TABLE OF CONTENTS: 1.0 PRODUCT OVERVIEW...1
NovelBright LED Illuminator
NovelBright LED Illuminator Instruction Manual version NS01_11 Instruction Manual This LED illuminator is suitable for research use only. It must be used by specialized personnel that know the health risks
WSN: XXXXXX 101 ROME COURT FORT COLLINS, CO, PHONE #: (970) FAX #: (970) TO-Clean Manual
WSN: XXXXXX 101 ROME COURT FORT COLLINS, CO, 80524 PHONE #: (970) 221-9179 FAX #: (970) 221-9364 TO-Clean Manual Copyright 2008 by Wasson ECE Instrumentation, Inc. (SJC 02/05/2008) All rights reserved
USER'S GUIDE. Digital Barometers with Analog Output PTB210 Series M210670EN-B
USER'S GUIDE Digital Barometers with Analog Output PTB210 Series M210670EN-B PUBLISHED BY Vaisala Oyj Phone (int.): +358 9 8949 1 P.O. Box 26 Fax: +358 9 8949 2227 FIN-00421 Helsinki Finland Visit our
accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS
18 GAUGE 1-1/4 INCH BRAD NAILER Model: 7611 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.
Lap Count Display Owner s Manual
Lap Count Display Owner s Manual Model 6673AW -Rev A Model 6673AX -Rev A RaceAmerica Corporation 105 Bonaventura Drive San Jose, CA 95134 (408) 988-6188 www.raceamerica.com info@raceamerica.com Copyright
WELCOME TO THE REVOLUTION
USER GUIDE WELCOME TO THE REVOLUTION THANK YOU FOR CHOOSING THE GCQUAD We listened to what you wanted - and created the most accurate, versatile and game-enhancing ball and club analysis solution available
1 METRON MANIPULATION TABLES - WARRANTY STATEMENT
1 METRON MANIPULATION TABLES - WARRANTY STATEMENT Metron Medical Australia Pty Ltd. will warrant this table, for parts only against defects in manufacture for a period of two (2) years for structural integrity,
AUTOMATIC FILM APPLICATOR MICROPROCESSOR CONTROLLED. Operating Instructions for the
TQC AUTOMATIC FILM APPLICATOR AB3120, AB3220, AB3320, AB3125, AB3225, AB3325 IMPORTANT! Before taking this instrument in use we strongly advise you to read this manual carefully. Operating Instructions
Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17
Operation Manual O2 Quickstick Oxygen Analyzer 08.17 If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: 805-815-4044 FAX:
Operation Manual. O2 Quickstick. Oxygen Analyzer
Operation Manual O2 Quickstick Oxygen Analyzer 01.11 www.nuvair.com If you have any questions on this equipment please contact Technical Support at: Nuvair 2949 West 5 th St. Oxnard, CA 93030 Phone: 805-815-4044
Psyclone TM. Protimeter Thermo-Hygrometer. GE Sensing. Operating Manual. INS7800, Rev. A (September 2007)
GE Sensing Psyclone TM Protimeter Thermo-Hygrometer Operating Manual INS7800, Rev. A (September 2007) Psyclone is a Protimeter product. Protimeter has joined other GE high-technology sensing businesses
Accu-Tab PowerBase 3012AT by Axiall Corporation
Accu-Tab PowerBase 3012AT by Axiall Corporation Installation and Operating Instructions DANGER: DO NOT MIX CHEMICALS! The PowerBase 3012AT chlorinator system is designed for use with Axiall Corp. approved
Portable Compressed CO 2 Regulator
Portable Compressed CO 2 Regulator 99901 Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com
ODOROMETER. Portable Gas Odorant Tester Part Number Operation and Maintenance Manual Instruction P/N: Rev. 17 June 2011 WARNING!
Portable Gas Odorant Tester Part Number 5110-0200 Operation and Maintenance Manual Instruction P/N: 0023-9125 Rev. 17 June 2011 WARNING! Because this instrument is used to detect and monitor materials
Installation and Operating Manual
Safety Instructions Important Information Please read prior to installation ATTENTION! ELECTRICAL HAZARD FOR INGROUND POOLS AND ABOVEGROUND POOLS Installation and Operating Manual IMPORTANT Pool Owner,
accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS
18 GAUGE 2 INCH BRAD NAILER Model: 7555 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.
Portable Gas Monitor GX User Maintenance Manual (H4-0050)
H4E-0050 Portable Gas Monitor GX-8000 User Maintenance Manual (H4-0050) Need of Maintenance and Servicing This gas monitor must be maintained in a normal state at all times to prevent accidents due to
HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions
HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions For the following Models: 40A00-1 HAI 15A Relay Switch (referred to as HAI UPB Wall Switch, in this document), and
FPD20 Series. Gear wheel flow sensor
. FPD20 Series Gear wheel flow sensor Series FPD20-2 - M-5455/0315 Series FPD20 Table of contents page 0 About this operating manual... 4 1 Device description... 5 1.1 Intended use... 5 1.2 Exclusion of
file:///users/samuel/documents/delft/masters/4th%20year%20su... APCO AVIATION USER MANUAL High-Rise Rescue Chute
APCO AVIATION USER MANUAL High-Rise Rescue Chute INDEX Introduction Disclaimer & Warranty Use Introduction The High-Rise Rescue Chute was developed after the tragic events of September 11 2001 in New York,
U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified
U S E R M A N U A L AIR FLOWMETER MODELS: 1MFA2001 (shown) 1MFA9001 ISO 13485 Certified Authorized Your EU local Representative: distributor: EMERGO EUROPE, INC. Molenstraat 15 2513866 BH -624 The -3952
Operator s Manual 701 Test Kit for Static Control Surfaces (Megohmmeter)
Operator s Manual 71 Test Kit for Static Control Surfaces (Megohmmeter) INTENDED USE The 3M Model 71 Megohmmeter is designed to measure the resistance of static control work surfaces and flooring. This
Agilent 490 Micro GC Natural Gas Analyzer
Agilent 490 Micro GC Natural Gas Analyzer User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2012 No part of this manual may be reproduced in any form or by any means (including electronic
WARRANTY, QUICK START GUIDE
WARRANTY, QUICK START GUIDE ONE-YEAR LIMITED PRODUCT WARRANTY BABOLAT warrants to the original purchaser that the BABOLAT PLAY PURE DRIVE (the Product ) is free from defects in material or workmanship,
120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank
120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank PART NO. 20003 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of
RPS900W Redundant Power Supply. Installation Guide.
RPS900W Redundant Power Supply Installation Guide www.edge-core.com Installation Guide RPS900W Redundant Power Supply Single DC Output Port with Dual Output Voltages RPS900W E10013-CS-R01 1500000081A
D90/91/92/93 Tyre Inflator Quick Start Manual
PART NUMBER SERIAL NUMBER D90/91/92/93 Tyre Inflator Quick Start Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100
MPS-1100 User Manual Mega Pool Saver Ltd PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100 For further up to date instructions on how to install Mega Pool Saver MPS 1100, please
SodaStream is the modern way to enjoy delicious bubbles. without the bottles. No more lugging or storing heavy
QUICK START GUIDE SPIRIT / FIZZY / EASY Please read this Quick Start Guide before using the Sparkling Water Maker. SMART SodaStream is the modern way to enjoy delicious bubbles without the bottles. No
2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL
2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL Model: 52024 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement,
SUUNTO ELEMENTUM AQUA USER GUIDE
SUUNTO ELEMENTUM AQUA USER GUIDE en A B SETTINGS MEMORY DIVE TIME Functions: _Time, date, alarm _Backlight _Auto dive mode _Depth, max. depth _Dive time _Surface time _Water temperature _Number of dives
Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520
Operating instructions Contents EN Pressure switch, heavy-duty version Model PSM-520 1. General information 2. Design and function 3. Safety 4. Transport, packaging and storage 5. Commissioning, operation
CONSERVATORY DIAGNOSTIC TOOLS TO MEASURE BUILDING PERFORMANCE
for the DG-700 Pressure and Flow Gauge The ENERGY CONSERVATORY DIAGNOSTIC TOOLS TO MEASURE BUILDING PERFORMANCE The Energy Conservatory 2801 21 st Ave. S., Suite 160 Minneapolis, MN 55407 Ph.: (612) 827-1117
Vessel Installation and Operating Manual
For In-ground and Aboveground Pools Vessel Installation and Operating Manual Important Safety Information Please read this manual prior to installation. Nature 2 Express is designed to sanitize in-ground
INSTRUCTION MANUAL. Microphone Type 4966 for Hand held Analyzer Types 2250, 2250 L and Supplement to Instruction Manual BE 1712
INSTRUCTION MANUAL Microphone Type 4966 for Hand held Analyzer Types 2250, 2250 L and 2270 Supplement to Instruction Manual BE 1712 BE 1897 11 English Microphone Type 4966 for Hand-held Analyzer Types
TC65M/15M TEMPERATURE CALIBRATOR USER S MANUAL
TC65M/15M TEMPERATURE CALIBRATOR USER S MANUAL Thank you for purchasing a Scan-Sense temperature calibrator. The products are manufactured by Scan-Sense AS in accordance with our high quality standards
The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.
The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is
OPERATION. Zinc Sprayer. For Maximum Working Pressure see page 2. Rev. E
OPERATION 309362 Rev. E U.S. Patent Pending Related manuals Zinc Sprayer....... 309340 List of Models, page 2 For Maximum Working Pressure see page 2....... 309092, 308438.. 307049.. 309342 INSTRUCTIONS
FLANGED TWO-PIECE BALL VALVES
INTRODUCTION This instruction manual includes installation, operation, and maintenance information for FNW flanged split-body ball valves. This manual addresses lever operated ball valves only. Please
IMPORTANT SAFETY INFORMATION
WARNING SYMBOLS AND DEFINITIONS This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury
PACKER OPERATING PROCEDURES
Inflatable Packer Manual Purchase Date: This manual belongs in Rig / Shop # Aardvark Packers LLC 450 California Street Grants Pass, OR 97526 Ph: 855-546-6488 Fax: 866-868-6665 Emergency Ph: 360-908-3283
Handi+N2 OPERATING MANUAL & INSTRUCTIONS FOR USE. R218M06 Industrial. R218M06 Rev. E
E N2 Handi+N2 OPERATING MANUAL & INSTRUCTIONS FOR USE R218M06 Industrial R218M06 Rev. E Maxtec TEL (801) 748. 5355 2305 S 1070 W FAX (801) 270. 5590 Salt Lake City, Utah 84119 www.maxtec.com USA CLASSIFICATION
Issue OWNER S MANUAL. GAMMA RACQUET SPORTS GAMMA Sports All Rights Reserved
OWNER S MANUAL CONTENTS PARTS LIST.. 2 ASSEMBLY INSTRUCTIONS.. 3 SWING WEIGHT TEST.. 4 RACQUET BALANCE TEST.. 5 RACQUET WEIGHT TEST.. 6 CALIBRATION - SWING WEIGHT.. 7 CALIBRATION - WEIGHT SCALE.. 8 MACHINE
RoVent Jr. Automatic Ventilator Volume & Pressure Controlled. User s Guide
RoVent Jr. Automatic Ventilator Volume & Pressure Controlled User s Guide TABLE OF CONTENTS Introduction... 1 System Components...1 Navigating RoVent Jr.... 2 Touchscreen... 2 Control... 2 Display Options...
COMPACT METAL bender 99826
COMPACT METAL bender 99826 Set up And Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com
PS-425 Pitot-Static/Air Data Tester
PS-425 Pitot-Static/Air Data Tester OPERATION AND MAINTENANCE MANUAL Preston Pressure LLC 580-286-3161 prestonpressure.com Revision 1, February 16, 2011 PRESTON PRESSURE LLC PS-425 USER AND MAINTENANCE
User Manual MFCS TM -EZ
User Manual MFCS TM -EZ Version 6A_December 2016 1. INTRODUCTION 5 2. GENERAL INFORMATION 6 2.1 General functioning 6 2.2 Different MFCS TM 6 3. PACKAGE CONTENT 8 4. MFCS TM -EZ DESCRIPTION 9 5. CONNECTIONS
UNIVERSAL TUBE HOLDER SYSTEM
UNIVERSAL TUBE for Constant Low Flow & Constant-Pressure (Multi-Flow) Operation INSTRUCTION MANUAL 16333 Bay Vista Dr. Clearwater, Florida 33760 (800) 451-9444 (727) 530-3602 (727) 539-0550 [FAX] Revision
U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.
U S E R M A N U A L 1600 SERIES OXYGEN REGULATOR 168715G (Shown) SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090
FRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System
FRESH AERO OneOP Model RC (Reservoir/tank) Tire Inflating System For inflating aircraft tires and all types of other vehicle tires and air operated devices Manual The Steelebrook Group Where Imagination
Model 4140/4143 General Purpose Thermal Mass Flowmeter
Mass Flowmeters Model 4140/4143 General Purpose Thermal Mass Flowmeter Operation and Service Manual 1980383, Revision C April 2003 TSI Model 4140/4143 General Purpose Thermal Mass Flowmeter Operation
ROPV R40 E Series User Manual
HARBIN ROPV INDUSTRY DEVELOPMENT CENTER ROPV R40 E Series User Manual For Use with the Following ROPV Pressure Vessel Models: R40 300E R40 450E Headquarters Tel:(+86)451-82267301 Fax:(+86)451-82267303
PM105 PRESSURE METER USER S MANUAL
PM105 PRESSURE METER USER S MANUAL Manual revision: 15 March, 2001 SCSMANP015 Copyrighted 2001 Thank you for purchasing a Tek Know pressure meter. The Tek Know products are manufactured by Scan-Sense AS
The Univentor 1250 Anaesthesia Unit
THE UNIVENTOR 1200/1250 ANAESTHESIA UNIT The Univentor 1250 Anaesthesia Unit TABLE OF CONTENTS EDITION 1 Section 1 - WARRANTY & SERVICE 1.1. WARRANTY 2 1.2. DAMAGED SHIPMENTS 2 1.3. SERVICE 2 Section 2
User Manual. Quantos Automated Dosing Liquid Module
User Manual Liquid Module 1 Safety Information 1.1 Definition of warnings and symbols Signal Words WARNING for a hazardous situation with medium risk, possibly resulting in severe injuries or death if
OPERATING INSTRUCTIONS FOR PRO HE HELIUM ANALYZER DANGER
OPERATING INSTRUCTIONS FOR PRO HE HELIUM ANALYZER P/N He Rev 1 DANGER This instrument is designed to monitor the helium concentrations in a gas mixing process. When processing gas mixtures intended for
Machine Cutting Torches Series 4700
ADI 1580-E Certified ISO 9000 Machine Cutting Torches Series 4700 INSTRUCTIONS Before Installing, Operating or Servicing Read and Comply With These Instructions This symbol on the product means the product
IMPACT WRENCH ASSEMBLY AND OPERATING INSTRUCTIONS
1 / 2 COMPACT AIR TWIN HAMMER IMPACT WRENCH 94802 ASSEMBLY AND OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission
2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS
Parker Hannifin Corporation Precision Fluidics Division Porter Instrument 245 Township Line Road Hatfield, PA 9440 Office 25-723-4000/Fax 25-723-506 www.porterinstrument.com 2 CYLINDER MOBILE CART USER
RGC-IR Remote Gas Calibrator for IR400
Remote Gas Calibrator for IR400 The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by
Certified ISO 9000 INSTALLATION AND OPERATION INSTRUCTIONS. Before Installing or Operating, Read and Comply with These Instructions
ADI 1219-M Certified ISO 9000 1600 Series Dual-Range Flowmeters INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls Corporation of America
10 DRIP NOZZLE WATERING DRIP KIT Model / Model 46095
10 DRIP NOZZLE WATERING DRIP KIT Model 93261 / Model ASSEMBLY AND OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission
Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions
Compact Triple Cabinet Outlet Station Model 6258-1 Installation and Operating Instructions The Porter Compact Triple Outlet Station (6258-1) provides a quick, safe, and reliable method of connection to
Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions
PORTER Parker Hannifin Corporation Porter Instrument Division 245 Township Line Rd. P.O. Box 907 Hatfield, PA 19440-0907 USA (215) 723-4000 / fax (215) 723-5106 Compact Triple Cabinet Outlet Station Model