1 Elcometer 2060 English ISO Groove Depth Checker Operating Instructions
2 English The Elcometer 2060 ISO Groove Depth Checker has been tested in accordance with EU regulations governing electro-magnetic compliance and meets the required directives. Note: Gauge readings may be affected if the unit is operated within a radio frequency electromagnetic strength of greater than 3 V/m. is a registered trademark of Elcometer Instruments Ltd. All other trademarks acknowledged. Copyright Elcometer Instruments Ltd All rights reserved. No part of this Document may be reproduced, transmitted, transcribed, stored (in a retrieval system or otherwise) or translated into any language, in any form or by any means (electronic, mechanical, magnetic, optical, manual or otherwise) without the prior written permission of Elcometer Instruments Ltd. Doc.No. TMA-0366 Issue 01 Text with Cover No: 19809
3 CONTENTS Section Page 1 About your depth checker Using your instrument Connecting to a PC Maintenance Technical specification Accessories Related equipment
4 Thank you for your purchase of this Elcometer 2060 ISO Groove Depth Checker. Welcome to Elcometer. Elcometer are world leaders in the design, manufacture and supply of inspection equipment for coatings and concrete. Our products cover all aspects of coating inspection, from development through application to post application inspection. The Elcometer 2060 is a world beating product. With the purchase of this gauge you now have access to the worldwide service and support network of Elcometer. For more information visit our website at 1 ABOUT YOUR DEPTH CHECKER The Elcometer 2060 ISO Groove Depth Checker is a precision instrument used to determine the accuracy of fineness of grind gauges in accordance with ISO standards. The instrument is set to zero and then placed on the fineness of grind gauge with the measuring needle resting on the bottom of the tapered groove. The depth of the groove at that point is shown on the display. Three readings are taken to provide an average depth at each graduation point along the tapered groove. The average depth must not differ by more than 3 µm (0.12 mils) from the nominal value at each graduation point. 1.1 STANDARDS The Elcometer 2060 ISO Groove Depth Checker can be used in accordance with the following standards: DIN EN ISO NF ISO
5 1.2 WHAT THE BOX CONTAINS Elcometer 2060 ISO Groove Depth Checker Glass zero plate Storage case Calibration certificate Digital gauge instructions a Operating instructions The Elcometer 2060 ISO Groove Depth Checker is packed in a cardboard and foam package. Please ensure that this packaging is disposed of in an environmentally sensitive manner. Consult your local Environmental Authority for further guidance. To maximise the benefits of your new Elcometer 2060 ISO Groove Depth Checker please take some time to read these Operating Instructions. Do not hesitate to contact Elcometer or your Elcometer supplier if you have any questions. a. The instruction leaflet provided by the manufacturer of the digital gauge explains how to fit the battery and other features and functions of the digital gauge. 3
6 PRESET R TOL. 2 USING YOUR INSTRUMENT When using the instrument, take care not to damage the V-shaped edge of the rule or the surface of the glass zero plate. When taking a measurement, always hold the instrument by the plastic thermal insulation strips either side of the rule. 2.1 ZERO THE INSTRUMENT 1. Press the ON/OFF button to switch on the instrument. 2. Place the glass zero plate on a flat surface. 3. Hold the instrument on the glass plate perpendicular to the surface of the glass. 4. Press the ZERO button and check that the display shows ZERO/ABS 0.000mm ON/OFF 4
7 R 2.2 TAKING A READING 1. Having set the instrument to zero, place the instrument on the surface of the fineness of grind gauge at the deepest end. 2. Align the measuring needle with a graduation mark on the scale of the fineness of grind gauge and the centre line of the groove (position B). 3. Check that the instrument is perpendicular to the surface of the fineness of grind gauge with the measuring needle touching the bottom of the tapered groove. 4. Record the depth of the groove from the display. 5. Repeat steps 1 to 4 above at each side of the groove (positions A and C). 6. Calculate the average of the three readings. When taking a reading, always hold the gauge here. If the average groove depth differs by more than 3 µm (0.12 mils) from the nominal value at the graduation point, the fineness of grind gauge is faulty and must be repaired or replaced. 7. Repeat steps 1 to 6 above at each graduation point of the fineness of grind gauge. 2.3 AFTER USE When you have finished taking readings, replace the instrument and glass zero plate in the protective case provided. ZERO/ABS A 0.030mm PRESET B Fineness of Grind Gauge TOL. C ON/OFF 5
8 3 CONNECTING TO A PC Your gauge can be connected to a PC to allow measurement data to be saved as it is collected. To connect to a PC, the following accessories will be required: Computer connection cable Dataputer 1CHM Multiplexer (Signal converter) DATA-XL software See Accessories on page 7 for ordering information. 4 MAINTENANCE The Elcometer 2060 ISO Groove Depth Checker is designed to give many years reliable service under normal operating and storage conditions. Regular calibration checks over the life of the gauge are a requirement of quality management procedures e.g. ISO 9000 and other standards. For checks and certification contact Elcometer or your local Elcometer supplier. Details of Elcometer offices around the world are given on the outside cover of these Operating Instructions. Alternatively visit the Elcometer website, 6
9 5 TECHNICAL SPECIFICATION Range: 0 mm to 6.48 mm (0" to 0.26") Resolution: 1 µm (0.04 mils) Accuracy: 3 µm (0.12 mils) Width of 60 mm (2.36") measuring edge: Battery: 1.5 V, SR44 button cell b 6 ACCESSORIES The following optional items are available from your local supplier or direct from Elcometer: Computer connection cable: KT002060P004 Dataputer 1CHM Multiplexer: M001CHM (Signal converter) DATA-XL software: M500DXL b. Batteries must be disposed of carefully to avoid environmental contamination. Please consult your local environmental authority for information on disposal in your region. Do not dispose of any batteries in fire. 7
10 7 RELATED EQUIPMENT In addition to the Elcometer 2060 ISO Groove Depth Checker, Elcometer produces a wide range of other equipment for measuring the physical characteristics of surface coatings. Users of the Elcometer 2060 may also benefit from the following Elcometer products: Elcometer 2000 Muller Laboratory Grinder Elcometer Fineness of Grind Gauges Elcometer Viscosity Cups and Rotational Viscometers For further information contact Elcometer, your local supplier, or visit our website at 8
Elcometer 123. Surface Profile Gauge. Operating Instructions
Elcometer 123 English Surface Profile Gauge Operating Instructions English is a registered trademark of Elcometer Limited. All other trademarks acknowledged. Copyright Elcometer Limited. 2009. All rights
More informationElcometer Viscosity Cup. Operating Instructions
Elcometer 2350 2351 2352 2353 2354 English Viscosity Cup Operating Instructions English is a registered trademark of Elcometer Limited. All other trademarks acknowledged. Copyright Elcometer Limited. 2009/2010.
More informationElcometer 125. Surface Profile Comparator. Operating Instructions
Elcometer 125 English Surface Profile Comparator Operating Instructions English is a registered trademark of Elcometer Limited. All other trademarks acknowledged. Copyright Elcometer Limited. 2009. All
More informationElcometer 138. Bresle Kit and Patches. Operating Instructions
Elcometer 138 English Bresle Kit and Patches Operating Instructions R English The Conductivity Meter model B-173 has been tested in accordance with EU regulations governing Electro-magnetic compliance
More informationElcometer 138. Bresle Kit and Patches. Operating Instructions
Elcometer 138 English Bresle Kit and Patches Operating Instructions R English This product meets the Electromagnetic Compatibility Directive. The product is Class B, Group 1 ISM equipment according to
More informationElcometer 406L. Statistical Glossmeter. Operating Instructions
Elcometer 406L English Statistical Glossmeter Operating Instructions English The Elcometer 406L Statistical Glossmeter has been tested in accordance with EU regulations governing Electro-magnetic compliance
More informationPressure Calibrators. Series PC..., PM...
Pressure Calibrators Series PC..., PM... SIKA-Precision Pressure Calibrators, Series PC..., PM... We help you, if you are under pressure! Pneumatic pressure calibrators PM 25 A, PM 25 D, PM 110 PIC pressure
More informationElcometer 2300 Rotational Viscometers. elcometer.com
elcometer.com 1 Available in four versions with a choice of low to medium or medium to high viscosity ranges, either manually or PC controlled, the range of rotational viscometers can be used to measure
More informationPneumatic service kit Model CPG-KITP
Calibration technology Pneumatic service kit Model CPG-KITP WIKA data sheet CT 93.01 Applications Oil and gas industry Maintenance and service facilities Calibration service companies and service industry
More informationSTARLOG. Capacitive Water Depth Probe
STARLOG Capacitive Water Depth Probe Model 6521 User Manual Supplement 6219 Revision D July 10. 1998 Copyright Notice Copyright Unidata Australia 1998. All rights reserved. No part of this publication
More informationDigital pressure gauge Model CPG500
Calibration technology Digital pressure gauge Model CPG500 WIKA data sheet CT 09.01 Applications Calibration service companies and service industry Measurement and control laboratories Quality assurance
More informationUser Manual PTW-DensiX. D / Di/Zi
User Manual PTW-DensiX D148.131.0/3 2005-05 Di/Zi General Information General Information The product bears the CE-mark "CE-0124" in accordance with the Council Directive 93/42/EEC about Medical Devices
More informationWATERPROOF DIGITAL DEPTH GAGES
WATERPROOF DIGITA DEPTH GAGES ATTENTION: NO ATTENTION: IT IS NECESSARY TO SET ZERO AFTER POWER ON EACH TIME IP ust/waterproof Button function: zero, on/off, mm/inch, ABS/RE, hol Meet DIN82 Mae of stainless
More informationBD Cytopeia Fluidic Kit User s Guide
BD Cytopeia Fluidic Kit User s Guide For Research Use Only 23-17618-00 9/2015 Becton, Dickinson and Company BD Biosciences 2350 Qume Drive San Jose, CA 95131 USA BD Biosciences European Customer Support
More informationTarget disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version
Target disk flowmeter Series DP Instructions manual DP65 DP500 R-MI-DP Rev.: 4 English version PREFACE Thank you for choosing the flowmeter series DP from Tecfluid S.A. This instruction manual allows the
More informationGAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE
GAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE www.helantec.de Gas filling - visibly better! 2 Managing partners Jochen Weiß and Gregor Witrofsky Advantage for you Worldwide, HELANTEC is the
More informationAbout us. Try us to trace your network!
About us Company KOMPLEX was founded in 1994 by Mr. Stefan Sivak in Zilina, Slovakia. KOMPLEX focuses on development and production of Radio Frequency Identification Systems assigned for underground networks.
More informationCadence Sensor W.I.N.D. User Manual
Cadence Sensor W.I.N.D. User Manual Polar Cadence Sensor W.I.N.D. is designed to measure cadence, i.e. crank revolutions per minute when cycling. No other use is intended or implied. Please follow the
More informationDigital Melting Point Apparatus
Digital Melting Point Apparatus Heating Plateau Ramping Start/Stop Plateau set Ramp stop Hold User Guide Version 1.1 Heating Viewing tube Sample Chamber IEC power inlet socket Power on/off Temperature
More informationPeak Pressure Indicator MSI-3
Peak Pressure Indicator MSI-3 Operating Instructions Cylinder Pressure Monitoring Digital Pressure Indicator DPI No installation Ready to use High quality sensor Large memory Easy handling Cost effective.com
More informationBS ml Bottle Sampling Unit
BS500 500ml Bottle Sampling Unit User Guide www.mpfiltri.co.uk 200.307-EN Covers Model Numbers BS500 SAFETY WARNING Hydraulic systems contain dangerous fluids at high pressures and temperatures. Installation,
More informationIDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05
IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger
More informationAccurate, easy to use and reliable: Easy to use control panel. Clear, backlit LCD display:
Elcometer 2300 Rotational Viscometers The Elcometer 2300 range of rotational viscometers measures the viscosity of liquids in accordance with several standards. Using a rotational viscometer, the properties
More informationWe measure it. For gas and water installers. testo hpa. bar
Pressure measuring instruments For gas and water installers testo 312-2 hpa testo 312-3 testo 312-4 bar C testo 312-2 / testo 312-3 Pressure meters for gas and water fitters testo 312-2 testo 312-2, fine
More information973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS
Precise and Stable SF 6 Gas Analyzer Simultaneous measurement of humidity, SF 6 purity and SO 2 concentration Integrated gas recovery system with automatic pump back Fully automated SF 6 gas testing Fundamental
More information130 SSP Soluble Salt Profiler
130 SSP Soluble Salt Profiler Conforms to: SSPC Guide 15, Bresle Equivalent ISO 8502-9 Test Method Page 1 of 6 The Elcometer 130 Soluble Salt Profiler provides fast and accurate measurement of the level
More informationWSN: XXXXXX 101 ROME COURT FORT COLLINS, CO, PHONE #: (970) FAX #: (970) TO-Clean Manual
WSN: XXXXXX 101 ROME COURT FORT COLLINS, CO, 80524 PHONE #: (970) 221-9179 FAX #: (970) 221-9364 TO-Clean Manual Copyright 2008 by Wasson ECE Instrumentation, Inc. (SJC 02/05/2008) All rights reserved
More informationDigital pressure gauge Model CPG500
Digital pressure gauge Model CPG500 WIKA data sheet CT 09.01 for further approvals see page 3 Applications Calibration service companies and service industry Measurement and control laboratories Quality
More informationASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation
ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS 2000 Dionex Corporation Document No. 031277 Revision 03 April 2000 2000 Dionex Corporation All rights reserved worldwide. Printed in the United States of
More informationMS-500. User Manual. MS-500 (500g x 0.1g) Copyright 2010 Fast Weigh Scales All rights reserved. Rev. 2.0
User Manual MS-500 (500g x 0.1g) Copyright 2010 Fast Weigh Scales All rights reserved. Rev. 2.0 Thank you for purchasing the Fast Weigh MS-500 digital pocket scale. Please read all operating instructions
More informationSAUTER FK Version /2016 GB
Sauter GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@sauter.eu Tel: +49-[0]7433-9933-199 Fax: +49-[0]7433-9933-149 Internet: www.sauter.eu Instruction Manual Digital Force Gauge SAUTER FK Version 1.4 12/2016
More informationAccurate, easy to use and reliable: Easy to use control panel. Clear, backlit LCD display: Quick connect spindles:
Elcometer 2300 Rotational Viscometers The Elcometer 2300 range of rotational viscometers measures the viscosity of liquids in accordance with several standards. Using a rotational viscometer, the properties
More informationPM105 PRESSURE METER USER S MANUAL
PM105 PRESSURE METER USER S MANUAL Manual revision: 15 March, 2001 SCSMANP015 Copyrighted 2001 Thank you for purchasing a Tek Know pressure meter. The Tek Know products are manufactured by Scan-Sense AS
More informationDFX II Series. Digital Force Gauge
DFX II Series Digital Force Gauge Functions and Features Simple Operation User friendly four button operation for; Peak, Units, Zero and Info. PEAK- change from Normal to Peak mode UNITS- select desired
More informationDM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More informationInstruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.
Hach LDO Sensor Instruction Sheet 00745589 Safety Precautions Please read this entire instruction sheet before operating this sensor. Pay particular attention to all danger and caution statements. Failure
More informationTest pumps. Pressure sources. Good reasons for proper and reliable calibration
Test pumps Pressure is one of the most commonly measured quantities in engineering, which is why exact and reliable pressure measurement is especially important. However, the characteristics of the even
More informationETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More informationPRESSURE COMPARATOR 10000PSI 700bar. Operator Instructions CRYSTAL. engineering corporation
PRESSURE COMPARATOR GauGeCaLXP 10000PSI 700bar Operator Instructions Page 2 GaugeCalXP Operator Instructions PRESSURE is Our BUSINESS Introduction Thank you for purchasing a GaugeCalXP Pressure tor from
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationGeneral Accreditation Guidance. User checks and maintenance of laboratory balances
General Accreditation Guidance User checks and maintenance of laboratory balances January 2018 Copyright National Association of Testing Authorities, Australia 2010 All intellectual property rights in
More informationEC214 EC215 - EC215R Bench Conductivity Meters
Instruction Manual EC214 EC215 - EC215R Bench Conductivity Meters http://www.hannainst.com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments
More informationOPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051
NOT SCALE / IF IN DOUBT ASK* DIVE CALIPER OPERATION MANUAL *THIS INFORMATION IS THE PROPERTY OF ZEBRA-TECH LTD. ALL RIGHTS RESERVED.* *ALL UNITS IN MM/DEGREES UNLESS SPECIF SURFACE F 3.2 Ra UNLESS S Part
More informationBCM-Series. User Manual. American Weigh Scales. BCM-100 (100g x 0.01g) BCM-650 (650g x 0.1g)
American Weigh Scales BCM-Series User Manual BCM-100 (100g x 0.01g) BCM-650 (650g x 0.1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 1.2 BCM-Series Manual Thank you for purchasing
More informationQ2: Which instruments are necessary for monitoring the groundwater level?
Micro-Diver 1. Q: What do Divers actually do? 2. Q: Which instruments are necessary for monitoring the groundwater level? 3. Q: Can I place the Diver close to an electrical pump? 4. Q: How should I install
More information12V MINI AIR COMPRESSOR
12V MINI AIR COMPRESSOR STOCK No.65958 PART No.DA12/250A INSTRUCTIONS IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS TOOL. 08/2001 GENERAL INFORMATION
More informationDM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø
More informationOperating manual for the pressure transducer unit CCS 1000
Operating manual for the pressure transducer unit CCS 1000 Please read the operating manual before using the device. 1 Content: 1. General description 2. Technical data 3. Operation 4. Scope of supply
More informationAgilent Flowmeter ADM1000
Agilent Flowmeter ADM1000 Operating Instructions Notices Agilent Technologies, Inc. 2003 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval
More informationVLI Visible Level Interface Operation & Maintenance Manual
VLI Visible Level Interface Operation & Maintenance Manual All rights reserved. Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted
More informationAA GWR Water Retention Meter for Accurate Measurement of Water Retention
AA GWR Water Retention Meter for Accurate Measurement of Water Retention Principle of Measurement: Coating color is poured into a test cell and separated from a blotting paper with a filter. The cell is
More informationSensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual
Sensor for Air Bubble Detection at Liquid Filled Tubes SONOCHECK Type ABD06.xx Operating Manual Manufacturer: Model: Type: SONOTEC Ultraschallsensorik Halle GmbH Air Bubble Detector ABD06.xx SONOTEC Ultraschallsensorik
More informationAXIS. User Manual. American Weigh Scales. AXIS-100 (100g x 0.01g) AXIS-650 (650g x 0.01g)
American Weigh Scales AXIS User Manual AXIS-100 (100g x 0.01g) AXIS-650 (650g x 0.01g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 1.0 AXIS Manual Thank you for purchasing the
More informationHI 2314 HI 2315 HI 23151
Instruction Manual HI 2314 HI 2315 HI 23151 Multi-Range Conductivity Meters for Laboratories www.hannainst.com Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction
More information12V Mini Air Compressor
INSTRUCTIONS FOR 12V Mini Air Compressor Stock No.80999 Part No.DA12/250B IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS PRODUCT. GENERAL INFORMATION This
More informationTEMPERATURE GRADIENT PLATE MFFT 10 / MFFT 20 VF9700 / VF9600
TEMPERATURE GRADIENT PLATE MFFT 10 / MFFT 20 VF9700 / VF9600 PRODUCT DESCRIPTION The new designed temperature gradient plate for measuring the Minimum Film Forming Temperature, MFFT BUSINESS Laboratories,
More informationAlpha Series. Main Features > Data displayed Selected speed r.p.m Selected spindle SP
Viscosímetros rotacionales Alpha series viscometers allow fast and accurate viscosity readings. They are low budget and easy to use. Alpha Series > Data displayed Selected speed r.p.m Selected spindle
More informationProgrammable pressure and temperature transmitters PTM/RS485
Programmable pressure and temperature transmitters PTM/RS485 Version: 03-28-2012 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x
More informationDigital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN
Data Sheet: DFP.418.R4.EN www.ntt.dk Digital Pressure Gauge PRESSURE FORCE The DFP series digital gauges are made according to the more modern technologies in order to provide a high level of reliability,
More informationEPSILON. User Manual. EP-5KG (5000g x 1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0
User Manual EP-5KG (5000g x 1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0 Thank you for purchasing the American Weigh EPSILON digital kitchen scale. Please read all operating
More informationCÜBE. User Manual. American Weigh Scales. CUBE-100 (100g x 0.01g) CUBE-650 (650g x 0.1g)
American Weigh Scales CÜBE User Manual CUBE-100 (100g x 0.01g) CUBE-650 (650g x 0.1g) Copyright 2014 American Weigh Scales, Inc. All rights reserved. Rev. 1.0 CUBE Manual Thank you for purchasing the American
More informationTensiometer For the measurement of surface and interfacial tension
Tensiometer For the measurement of surface and interfacial tension Precise measuring instruments for research and industry Precision, flexibility, and reliability LAUDA Scientific offers proven solutions
More informationTABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 3 PACKAGE CONTENTS 4 DEVICE OVERVIEW 4 BUTTON OPERATION SUMMARY 5 BASIC OPERATION 6
TABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 3 PACKAGE CONTENTS 4 DEVICE OVERVIEW 4 BUTTON OPERATION SUMMARY 5 BASIC OPERATION 6 CURRENT TIME MODE 7 FUNCTIONAL DISPLAY 7 WEATHER FORECAST FEATURE
More informationTensiometer For the measurement of surface and interfacial tension
Tensiometer For the measurement of surface and interfacial tension Precise measuring instruments for research and industry Precision, flexibility, and reliability LAUDA Scientific offers proven solutions
More informationGetting to know your Sureshotgps micro V3
Getting to know your Sureshotgps micro V3 Battery State Symbol Satellite Signal Shows distance to front, centre and rear of each green Hole Number Real Time Power on and Enter Key Down (backward) Key 1
More information_ pressure transducers. User Manual
_ pressure transducers User Manual summary introduction DescriPTION preliminary checks Installation taking measurements data management Troubleshooting maintenance Appendix 1 Page 4 Page 5 Page 6 Page
More informationCourseware Sample F0
Electric Power / Controls Courseware Sample 85303-F0 A ELECTRIC POWER / CONTROLS COURSEWARE SAMPLE by the Staff of Lab-Volt Ltd. Copyright 2009 Lab-Volt Ltd. All rights reserved. No part of this publication
More informationOxyCheq Expedition-X Oxygen Analyzer. Operator s Manual
OxyCheq Expedition-X Oxygen Analyzer Operator s Manual OxyCheq 3528 Russell Road Marianna, Florida 32446 USA Tel: 850.482.0385 Email: oxy@oxycheq.com Web: http://oxycheq.com CONTENTS 1.0 Introduction..
More informationInfo Counting chamber (haemacytometer)
Info Counting chamber (haemacytometer) 1. What is a counting chamber and what is it used for? A counting chamber is a precision measuring instrument made of special optical glass. It is used to count cells
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationVibrating Wire Load Cell (3, 4, 5 And 6 Gauge Cells) User Manual
Vibrating Wire Load Cell (3, 4, 5 And 6 Gauge Cells) User Manual Man 188 1.1.0 06/08/2014 Chris Rasmussen Philip Day Chris Rasmussen Manual No. Revision Date Originator Checked Authorised for Issue User
More informationTQC Bresle Chloride test 2008
TQC Bresle Chloride test 2008 SP7310 MANUAL See also : ISO8502-6 ISO8502-9 1 DETERMINATION OF SOLUBLE CONTAMINANTS ON SURFACES IN CONFORMITY WITH ISO 1.1 PREPARATION With this system very low concentrations
More informationHydraulic hand test pump Models CPP700-H and CPP1000-H
Calibration technology Hydraulic hand test pump Models CPP700-H and CPP1000-H WIKA data sheet CT 91.07 for further approvals see page 2 Applications Simple test pressure generation on site, in the laboratory
More informationUniversal Gage. Multimar 844 T
Universal Gage Multimar 844 T Operating Instructions 3722483 0315 Mahr GmbH Standort Esslingen Reutlinger Str. 48, 73728 Esslingen Tel. +49 711 9312-600, Fax +49 711 9312-756 mahr.es@mahr.de, www.mahr.com
More informationFeltest AirSpeed/2 Instruction manual
Feltest AirSpeed/2 Instruction manual 2 1. Table of contents 3 2. Safety instructions 4 2.1 Intended use 4 2.2 Safety precautions 4 3. About the instrument 6 3.1 Names of parts 6 3.2 Working principle
More informationInstrumentation & Data Acquisition Systems
Instrumentation & Data Acquisition Systems Section 3 -Level Robert W. Harrison, PE Bob@TheHarrisonHouse.com Made in USA 1 Level Section Question Which level measuring technology is the best solution when
More informationThermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.
Display Thermo, Inc. Instruction Manual English TP-5 Display TP-7 Display TP-8 1-1 Thermo, Inc. Instructions for use- Models TP-5, TP-7, and TP-8 The manual describes basic function and use of Thermo instruments
More informationSEMEM3-78 Testing and calibrating instrumentation and control equipment and circuits
Testing and calibrating instrumentation and control equipment and Overview This unit identifies the competences you need to carry out tests and calibration of instrumentation and control equipment and,
More informationBest Practice for Calibrating LTH Conductivity Instruments
Application Note Best Practice for Calibrating LTH Conductivity Instruments As accurate process measurement becomes an everyday requirement it is vital to be able to calibrate conductivity instruments
More informationElectronic gas volume corrector model DGVC-04
Electronic gas volume corrector model DGVC-04 1. Introduction The following user s manual gives information about the installation, configuration, usage and storage of the electronic gas volume corrector
More informationFPG8601 Force Balanced Piston Gauge
FPG8601 Force Balanced Piston Gauge Reference Level Calibration System for very low pressure Pressure range: 0 to 15 kpa gauge, absolute and absolute differential Standard resolution: 0.010 Pa, high resolution
More informationGMC-I Service GmbH Calibration Center
2016 GMC-I Service GmbH Calibration Center DAkkS, ISO & Factorycalibration www.gmci-service.com From spare parts, reparation, rental service, maintenance of industrial health and safety standards, calibration
More informationPRODUCT MANUAL. Diver Smart Interface Cable AS346
PRODUCT MANUAL Diver Smart Interface Cable AS346 Contact details: Van Essen Instruments B.V. Van Essen Instruments - Canada Delftechpark 20 630 Riverbend Drive, Suite 100 2628 XH Delft Kitchener, ON, The
More informationRigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0
Rigel 601 CHECKBOX Instruction Manual 348A551 Issue 2.0 April 2006 2006 Seaward Electronic Ltd. Issue 2.0 Limited Warranty & Limitation of Liability Rigel Medical guarantees this product for a period of
More informationEasy with a modular concept for future expansion
AVS 37 ViscoSystem AVS 370 makes maximum precision... Well equipped for every viscosity determination With the ViscoSystem AVS 370 we have created a measuring device, which not only measures as precisely
More informationI N N O V A T I O N C O N T I N U E S... International Patent Filed in 45 Leading Countries
I N N O V A T I O N C O N T I N U E S... Quick Check International Patent Filed in 45 Leading Countries World's First Single Piece Multi-Function Check Standard for Calibration or Verification of Various
More informationProgrammable pressure and temperature transmitters PTM/RS485
Programmable pressure and temperature transmitters PTM/RS485 Version: 26.06.2014 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x
More informationTSE Blood Pressure Monitor Invasive series
TSE Blood Pressure Monitor Invasive 209100series For Invasive Measurements in Laboratory Animals 2 Specifications subject to change without notice USA / Canada / Mexico Phone 1-989-698-3067 Fax 1-989-698-3068
More informationsafety Shut-Off Valve HON 721
safety Shut-Off Valve HON 7 product information serving the gas industry worldwide safety shut-off valve HON 7 safety shut-off valve HON 7 Application, Characteristics, Technical Data Application safety
More informationAqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.
TPS Australia - Quality hand-made instruments since 1968. Waterproof Dissolved Oxygen - ph -mv Temperature Meter Dual readout of Dissolved Oxygen and ph/mv Waterproof to IP65 Easy to use One-touch calibration
More informationVISCOMETER, OFI, 8-SPEED, MODEL 800 PART No
OFI Testing Equipment Viscometer, 8 Speed, Model 800 Instructions Part # 130-10 Page 1 of 4 VISCOMETER, OFI, 8-SPEED, MODEL 800 PART No. 130-10 The model 800 eight speed electronic viscometer is designed
More informationOPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.
English Lubrication Free Air Turbine Handpiece with Water Spray OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference. OM-T0286E 001 Thank you for purchasing
More informationAUTO RANGE Display of maximum measurable limits. Displayed Info Viscosity (cp or mpa s) % Torque Spindle Speed
Fungilab Quality + Low Budget = Viscolead Series Rotational Viscometers Viscolead One Original Fungilab Viscometer. Essential viscosity measurement. 2 years warranty Standard Delivery Viscometer head with
More informationDepth Micrometer Page 205. Depth Gauge Page 208. Depth Gauge Accessories Page 218
Depth Measuring Instruments Depth Micrometer Page 205 Depth Gauge Page 208 Depth Gauge ccessories Page 218 204 Measuring force Measuring span Spindle pitch Micrometer Head Feed (0-25 ) Flatness of reference
More informationRotational Viscometers RP1 RP2
INTENDED USE RAYPA viscometers, models RP1 and RP2, are rotational viscometers for the quick determination of viscosity as specified in ISO 2555 and other ASTM norms. Instrument offers a precise digital
More informationA i r c r a f t E l e c t r i c a l S y s t e m s ( 1 2 B )
8 5 4 9 A i r c r a f t E l e c t r i c a l S y s t e m s ( 1 2 B ) 40S/40E/40M An Aviation and Aerospace Technologies Course 8 5 4 9 : A i r c r a f t E l e c t r i c a l S y s t e m s ( 1 2 B ) 4 0
More informationDRYING TIME RECORDER AB3600. IMPORTANT! Before taking this instrument in use we strongly advise you to read this manual carefully.
DRYING TIME RECORDER AB3600 IMPORTANT! Before taking this instrument in use we strongly advise you to read this manual carefully. User Guide V1.5 0718 1 2 WARRANTY TQC Sheen will grant a warranty for a
More informationHand-held pressure calibrator with integrated pump Model CPH6600
Calibration technology Hand-held pressure calibrator with integrated pump Model CPH6600 WIKA data sheet CT 16.01 Applications Calibration service companies and service industry Measurement and control
More informationVWR UHP j :01 Page 1. ENGLISH 1 22 DEUTSCH FRANÇAIS ESPAπOL ITALIANO
VWR UHP 01.09.2010 5j 240.9001.0.09 1-09-10 16:01 Page 1 1 22 DEUTSCH 23 44 FRANÇAIS 45 66 ESPAπOL 67 88 ITALIANO 89 110 VWR UHP 01.09.2010 5j 240.9001.0.09 1-09-10 16:01 Page 2 Pipettors are equipped
More informationMTS Restan. Automatic System for Residual Stress Measurement by Hole-Drilling
Automatic System for Residual Stress The MTS3000 - Restan system for measuring residual stresses Fully automatic drilling and acquisition process ensuring high repeatability High speed drilling (400,000
More information