Catalogue November PPSU PUSH-FIT pipe connection system for plomypex and plomylayer pipes

Size: px
Start display at page:

Download "Catalogue November PPSU PUSH-FIT pipe connection system for plomypex and plomylayer pipes"

Transcription

1 Catalogue November 2009 PPSU PUSH-FIT pipe connection system for plomypex and plomylayer pipes Drinking water supply Hot and cold water supply SHW Heating Gas supply

2

3 Supplies the market with the widest range: Building and installation Civils Infrastructure Soil and waste Telecommunications ducting Gas supply Sanitary Cable ducting 50 years of tradition The Group finds its origins back in 1957 with the foundation of the company Plomífera Castellana s.a. Diversification, innovation and growth have been our drivers ever since thanks to state-of-the-art manufacturing equipment, in-house R&D and professionalism. 50 years of innovation Lead pipes PVC PE PP PP-R Multilayered PEX PPSU years IMPROVING THE ENVIRONMENT

4 Product Range Summary plomyclick plomypress plomyair PPSU PUSH-FIT pipe connection system for plomypex (PE-Xa) and plomylayer (PE-RT/AL/PE-RT) pipes. Applications: Drinking water supply, hot and cold water supply, SHW, Radiator Heating, Air Conditioning and Gas supply. PPSU PUSH-FIT pipe connection system for plomypex (PE-Xa) and plomylayer (PE-RT/AL/PE-RT) pipes. Pressing profiles type: RF, TH and U. Applications: Drinking water supply, hot and cold water supply, SHW, Radiator Heating, Air Conditioning and Gas supply. PUSH-FIT pipe connection system for plomyair (PE-RT/ AL/PE-RT) pipes. Applications: Compressed air systems and inert gas supply systems. plomyfloor Underfloor heating and cooling system. Applications: housing, industrial and agricultural. Technical manuals of all applications Technical manuals and software of underfloor heating system

5 Application fields plomyclick system has been designed for drinking water supply, hot and cold water supply, SHW, heating by radiators and Gas supply. Drinking water Heating by radiators SHW Cold water Gas supply

6 PPSU PUSH-FIT pipe fittings for plomypex (PE-Xa) and plomylayer (PE-RT/AL/PE-RT) pipes for Hot and Cold water supply, Gas supply, Compressed Air and Air Conditioning applications. This fitting has three different pre assembled elements (body, grip ring and sleeve) so that the connection between two or more plastic pipes is carried out naturally, by no further operations than applying the pipes a light axial pressure. Hence, no mechanical tools are required. Furthermore, another advantage of the installed fitting is its size, slightly larger than the respective pipe dimension. It makes this system suitable for either classic in-wall installations and new ones (synthetic, pladur, etc). Also, all plomyclick fittings have the property of allowing the pipe rotation even when the joint has been made. INSTALLING plomyclick FITTINGS IS EASY AND SIMPLE Cut pipe square PPSU polyphenylsulfone: a techno-polymer of high performance Thermal resistant Maximum service temperature of C Light-weight Seven times lighter than other brass or copper fittings Smooth inner surface Less pressure loss than metallic fittings Health-friendly All system components comply with the most stringent toxicological and hygienic requirements and are suitable for transporting drinking water. Toxicity is avoided and no smells or flavours can be brought to water Thermal sealant (0,26 W/m 0 C) 400 times less thermal conductivity than brass fittings and 1,400 times less than copper fittings Elongation at break Length increases from 50% to 100% before breaking Chemical resistance Can be used for industrial applications, such as with inorganic acids, base, salt solutions and alcohols. No galvanic corrosion or oxidation. Not being affected by regular construction materials. Not being affected by low Ph water (acid water) Calibrate and bevel No noise nuisance No noise nuisance originates due to the liquid flow. Reduced size / slim profile It makes this system suitable for either classic in-wall installations and new ones (synthetic, pladur, etc). Insert the pipe into the fitting. Visually check correct connection High profitability 80% installation time reduction. Inspection windows to check the pipe is fully homed

7 Fitting design PPSU Sleeve This element aims to prevent the pipe and grip ring from being removed. It is assembled on the BODY. PPSU Grip Ring This element grabs the pipe once inserted and acts as a blockade when interacting with the Sleeve. It is mounted on the BODY. Special sealing element (patented) PPSU Body This element reproduces different shapes in order to perform its respective functions. All plomyclick fittings are supplied already mounted and are not demountable. Water tightness assured from inside the pipe, thanks to technology coming from the gas supply installation wise. Because This way any malfunctioning responsibility relays on the Producer. This way most likely manipulation mistakes can be avoided. Several domestic installation codes, in different countries, indicate that only not demountable fittings are recommended for built-in installations without inspection CABINET. Why systems from a SINGLE producer should be used? Warranty from a SINGLE producer. Responsibility of a SINGLE producer. A SINGLE producer to deal with insurance companies. Designing and manufacturing carrying out by a SINGLE producer. Tested quality. System manufactured, tested and certified in a SINGLE manufacturing plant. Manufacturing standards ISO 21003: Multilayer piping systems for hot and cold water installations inside buildings. NTC1746 thermoplastic pipes and fittings for pressurised gas supply. ISO FDIS Multilayer pipe Systems for indoor gas installations. UNE EX. Multilayer pipes for hot and cold water supply. Polymer /AL/PE-RT pipes. UNE-EN ISO 15875: Plastic piping systems for hot and cold water installations cross linked polyethylene (PE-X). RP AENOR particular rules for plastic materials. Common requisites. RP 01.49: AENOR particular rues for hot and cold water supply. Polymer /AL/PE-RT pipes. RP 01.52: AENOR particular rules for plastic material canalisation systems for hot and cold water installations. RP 01.54: AENOR conformity certificate for mechanical joining of pipe canalisations (PE-X or PE-RT) for hot and cold water installations.

8 plomyclick PUSH-FIT connectors range PLOMYCLICK PPSU CONNECTION WITH MALE THREAD K /2 40 / 480 K /2 25 / 300 K /4 25 / 300 K /4 20 / 240 K / 120 PLOMYCLICK PPSU CONNECTION WITH FEMALE THREAD K /2 35 / 420 K /2 25 / 300 K /4 20 / 240 K /4 15 / 180 PLOMYCLICK PPSU COUPLING K / 480 K / 300 K / 180 K / 96 PLOMYCLICK PPSU REDUCER K / 300 K / 240 K / 240 K / 120 PLOMYCLICK PPSU ELBOW 90 O K / 300 K / 240 K / 120 K / 60

9 PLOMYCLICK PPSU TEE WITH FEMALE THREAD K /2 15 / 180 K /2 10 / 120 PLOMYCLICK PPSU ELBOW 90 O WITH FEMALE THREAD K /2 20 / 240 K /2 20 / 240 K /4 15 / 180 K /4 10 / 120 PLOMYCLICK PPSU WALL PLATE ELBOW K /2 15 / 180 K /2 15 / 180 PLOMYCLICK PPSU TEE K / 180 K / 120 K / 72 K / 36 PLOMYCLICK PPSU TEE WITH REDUCER T = 14 mm K / 180 K / 180 K / 180 K / 180 K / 120 K / 108 K / 108 K / 96 K / 60 plomyclick threaded fittings threads are GAS TYPE or straight type. plomyclick range female threaded sections length / depth is 14 mm. Hence, no male fittings with threaded part exceeding 14 mm can be used.

10 plomyclick PUSH-FIT connectors range PLOMYCLICK BRASS ELBOW 90 O WITH FEMALE THREAD LK / 240 LK / 240 LK / 180 LK / 120 LK / 60 PLOMYCLICK BRASS WALL PLATE ELBOW LK / 180 LK / 180 LK / 60 PLOMYCLICK BRASS BALL VALVE (BUILD-IN) K / 84 K / 72 K / 60 K / 36 PLOMYCLICK BRASS U-TYPE BALL VALVE (BUILD-IN) K / 60 K / 48 K / 36 BALL VALVE HANDLES MANDOP Chromed 5 / 60 MANDOM Chromed lever 10 / 120 MANDOO Chromed hidden 10 / 120 ALARGADOR Extension 100 / 1200 PLOMYCLICK TRANSITION FITTINGS (GAS COPPER PIPE) KCu1516 Cu12.70 Ø / 420 PLOMYCLICK BRASS BALL VALVE K / 84 K / 72 PLOMYCLICK BRASS BALL VALVE FEMALE THREAD K / 120 K / 96

11 4-DIMENSION BEVELLING TOOL K / 60 PLASTIC PIPE CUTTER to 25 (mm) 1 INSIDE BENDING SPRING 2516 Ø 16 mm. 0.6 m Ø 18 mm. 0.6 m Ø 20 mm. 0.6 m Ø 25 mm. 0.6 m Ø 32 mm. 0.6 m 1 OUTSIDE BENDING SPRING E2516 Ø 16 mm. 0.6 m 1 E2518 Ø 18 mm. 0.6 m 1 E2520 Ø 20 mm. 0.6 m 1 PLOMYCLICK PPSU PLUMBING MANIFOLD CODE INPUT OUTPUT QTY PACK A / B K M K M K M K M PLUMBING AND HEATING MANIFOLD BOX CODIGO INPUT OUTPUT QTY PACK A / B FC x 332 x 86 1 to 6 1 FC x 412 x 86 7 to 8 1 FC x 512 x 86 9 to 10 1 L Packaging All packs are labelled, including information on code, item description, quantity and EAN code. H label B A A Dimensions Pack type (LxWxH) mm QTY PACK A / B European pallet A 180 x 120 x B 390 x 385 x units of A type 800 x units of B type 504 units of B type

12 plomylayer PE-RT/AL/PE-RT Multilayer pipes Pipes manufactured according to standards ISO 21003, UNE 53960, ISO Head-to-head butt welding, allowing a perfect pipe concentricity. 100% oxygen tight pipe. This makes the pipe an ideal option for Heating and Gas supply installations. For drinking water supply, hot and cold water supply, SHW, heating and Gas supply. Installing plomylayer pipes spares a big number of elbow 90 o fittings in installations. Standard pipes without oxygen diffusion barrier may allow oxygen molecules (O2) get inside the pipe. plomylayer pipes plomylayer GAS pipes plomylayer pipes, due to their middle aluminium layer, do not allow oxygen molecules to get inside the pipe. plomylayer pipe CODE DESCRIPTION LENGHT (COIL /PALLET) (BAR/PACK/PALLET) MUL x 2 mm 50 / 1300 MUL x 2 mm 100 / 1600 MUL x 2 mm 200 / 2800 MUL x 2 mm 50 / 1300 MUL x 2 mm 100 / 1400 MUL x 2 mm 200 / 2400 MUL x 2.5 mm 25 / 350 MUL x 2.5 mm 50 / 650 MUL x 3 mm 25 / 325 MUL x 3 mm 50 / 550 MUL16B 16 x 2 mm A4 / B148 / C2812 MUL20B 20 x 2 mm A4 / B112 / C2128 MUL25B 25 x 2.5 mm A4 / B68 / C1292 MUL32B 32 x 3 mm A4 / B44 / C836 plomylayer GAS pipe CODE DESCRIPTION LENGHT (COIL /PALLET) (BAR/PACK/PALLET) COLOUR GA x 2 mm 100 / 1600 YELLOW GA x 2 mm 200 / 2800 YELLOW GA x 2 mm 100 / 1400 YELLOW GA x 2 mm 200 / 2400 YELLOW GA x 2.5 mm 50 / 650 YELLOW GA x 3 mm 25 / 325 YELLOW GA16B 16 x 2 mm A4 / B148 / C2812 YELLOW GA20B 20 x 2 mm A4 / B112 / C2128 YELLOW GA25B 25 x 2.5 mm A4 / B68 / C1292 YELLOW GA32B 32 x 3 mm A4 / B44 / C836 YELLOW A = straight lenght / B = Pack / C = Pallet plomylayer pipe. PRE-INSULATED A = straight lenght / B = Pack / C = Pallet CODE DESCRIPTION INSULATION THICKNESS COLOUR COIL LENGHT AMUL x 2 mm 6 mm GREY 25 AMUL x 2 mm 6 mm GREY 25 AMUL x 2.5 mm 9 mm GREY 25 plomylayer pipe. PIPE-IN-PIPE CODE DESCRIPTION COLOUR COIL LENGHT CAMUL x 2 mm BLUE 25 CRMUL x 2 mm RED 25 CAMUL x 2 mm BLUE 25 CRMUL x 2 mm RED 25 CAMUL x 2.5 mm BLUE 25 CRMUL x 2.5 mm RED 25

13 plomypex PE-Xa Cross-linked polyethylene pipes Linear chains of polymerized polyethylene by addition (2 Hydrogen atoms per each Carbon atom). By means of our Infra Red system, the O-O links of the peroxide molecule break. In order to get stabilised, it brings Hydrogen atoms from the polyethylene chain, producing free radicals. The numbers of polyethylene chains plus the Hydrogen free radicals react in order to make the system stable. Hence, a molecular mesh / network is produced, bringing the special pressure and temperature resistance to the PE-Xa pipe. Pipes manufactured according to standards ISO (Peroxide method, PE-Xa). Cross-inked polyethylene PEX, by Peroxide Xa system. Due to the special manufacturing process Peroxide Xa, the pipe is highly flexible and its crosslinking degree is truly homogenised. For drinking water supply, hot and cold water supply, SHW, and Heating. CODE DESCRIPTION SERIES DIMENSION TYPE XA x 2 mm 3.5 C 50 / 1300 XA x 2 mm 3.5 C 100 / 1600 XA x 2 mm 3.5 C 200 / 2800 XA x 2 mm 4.5 C 50 / 1300 XA x 2 mm 4.5 C 100 / 1400 XA x 2 mm 4.5 C 200 / 2400 XA x 2.3 mm 5 A 50 / 650 XA x 2.3 mm 5 A 100 / 1100 XA x 2.9 mm 5 A 25 / 325 XA x 2.9 mm 5 A 50 / 550 XA16B 16 x 2 mm 3.5 C A4 / B148 / C2812 XA20B 20 x 2 mm 4.5 C A4 / B112 / C2128 XA25B 25 x 2.3 mm 5 A A4 / B68 / C1292 XA32B 32 x 2.9 mm 5 A A4 / B44 / C836 plomypex pipe. PRE-INSULATED CODE DESCRIPTION INSULATION THICKNESS COLOUR COIL LENGTH AXA x 2 mm 6 mm GREY 25 AXA x 2 mm 6 mm GREY 25 AXA x 2.3 mm 9 mm GREY 25 LENGHT (COIL /PALLET) (BAR/PACK/PALLET) A = straight lenght / B = Pack / C = Pallet plomypex pipe. PIPE-IN-PIPE CODE DESCRIPTION COLOUR COIL LENGTH CAXA x 2 mm BLUE 25 CRXA x 2 mm RED 25 CAXA x 2 mm BLUE 25 CRXA x 2 mm RED 25 CAXA x 2.3 mm BLUE 25 CRXA x 2.3 mm RED 25

14 Sanitary installations application Manifold system installation Heating by radiators installations Branch system installation Branch system installation Cross-radiator installation Manifold system installation

15

16 Ingeniería Plástica del Sur s.l. PLOMYPLAS Group INTERNATIONAL LIMITED WARRANTY (10 years, ) Valid for plomypex pipes, plomylayer pipes, plomyair pipes, plomyclick fittings and plomypress fittings for Potable Water, Sanitary Hot Water, Heating systems and compressed air systems To Property Owners and Succeeding Owners During Warranty Period. Limited Warranty: INGENIERÍA PLÁSTICA DEL SUR s.l. warrants by means of its Liability Insurance Policy to the property owners and succeeding owners that the Products above mentioned shall be free from defects in material and workmanship, under normal conditions of use and for the applications stated in the respective manufacturing regulations. This limited warranty shall expire in: Ten (10) years. Ingeniería Plástica del Sur s.l. must receive written notification of a believed failure within the applicable warranty period, and within thirty (30) days of the believed breach. Emergency repairs may be carried out by the Property Owners and / or respective installer without notification. Should this occur, Ingeniería Plástica del Sur s.l., does not acknowledges any responsibility in relation to what might have originated the mentioned emergency repairs. Documentation on failures and likely causes must be provided to Ingeniería Plástica del Sur s.l. including components and acceptable length of pipe claimed to be defective. In the case of pipes, provided samples shall show all original marking on the pipe surface. In the case of fittings, protective bags will be provided if possible. LIMITED WARRANTY IIngeniería Plástica del Sur, s.l. PLOMYPLAS Group Autovía A92 Km. 209, E Moraleda de Zafayona, Granada (Spain) Tel Fax: ips@plomyplas.com Document: Limited Warranty OCTOBER 09 Also, Ingeniería Plástica del Sur shall pay, for consequential damages proved to be caused by any defective product of the ones listed above, up to a maximum of three million Euro ( ) per incident. This limited warranty applies only as per stated in this document and if the articles sold hereunder: (a) are not exposed to temperatures, pressures or temperatures and pressures that exceed the limitations printed on the pipe, or limitations stated in the manufacturers specification or limitations stated in the product regulations, (b) remain in their originally installed location, (c) show no evidence of mishandling, or accidental damage as a result of water freezing in the pipes, or use of chemicals other than those acceptable for potable use or listed by Ingeniería Plástica del Sur, s.l. (d) are installed in accordance with Ingeniería Plástica del Sur s.l. s instructions or its technical manuals or technical literature. (e) are installed and a valid, fully filled in and singed in Pressure Test Record form is provided. (f) the Limited Warranty Declaration jointly with the valid Pressure Test Record Form are submitted to Ingeniería Plástica del Sur s.l. via fax ( ) or via (garantia.ips@plomyplas.com). This must have occurred before the date specified on the installer s own installation report / form / bulletin. This warranty does not extend to parts, materials or equipment not manufactured by Ingeniería Plástica del Sur, s.l.

17 PRESSURE TESTS INSTRUCTIONS All installations must be pressure tested accordingly to DIN The procedure consists of two parts: Introductory test. Main test. Prior to carrying out the test: 1. A visual check must be carried out prior to pressure testing. 2. Flushing of the system should occur prior and after pressure testing. 3. Pressure gauges which can measure a pressure difference of 0,1 bar must be used. 4. The pressure gauge must be fitted at the lowest point of the installation. 5. Pipes must be filled up with filtered water without any air pocket. Introductory test: 30 minutes + 30 minutes. The introductory test involves applying a test pressure equal to 1.5 times the permissible operating pressure. This pressure must be re-stored twice within the space of 30 minutes at intervals of 10 minutes. Following a test period of a further 30 minutes, the test pressure must not have fallen by more than 0,6 bar. The installation must remain 100% watertight: no leakage. Main test: 120 minutes. The main test must be conducted immediately after the introductory test. The test takes 2 hours. At the end of this period, the test pressure recorded after the introductory test must not have fallen by more than 0,2 bar. The installation must remain 100% watertight: no leakage. Comments (if any):

18 Name / Identification: PROJECT Location / Address: Completion date: Owner or representative details: CONTRACTOR / BUILDER Name / Identification: Address: Tel.: VAT nº or Company Reg. nº: Fax: INSTALLER Name / Identification: Address: Tel.: VAT nº or Company Reg. nº: Fax: Description of products installed in the above-mentioned construction project: PRESSURE TEST RECORD FORM AND INSTRUCTIONS Ingeniería Plástica del Sur, s.l. PLOMYPLAS Group Autovía A92 Km. 209, E Moraleda de Zafayona, Granada (Spain) Tel Fax: ips@plomyplas.com Document: PTRF Sanitary October 09) 16 x 2.0 plomylayer: 16 x 2.0 plomypex: plomyclick fittings: 20 x 2.0 plomylayer: 20 x 2.0 plomypex: plomypress fittings: 25 x 2.5 plomylayer: 25 x 2.3 plomypex: 32 x 3.0 plomylayer: 32 x 2.9 plomypex: Total pipe length:...m. Test date:.../.../... Installation of test equipment:... Height of final water outlet above pressure indicator:... Person for the test / Name and contact details: Test pressure is 15 bar. Filling water was filtered and the pipeline system was fully vented: Yes No Water temperature:...ºc Ambient temperature:...ºc Pressure at test start: bar Time:... :... Test pressure 30 min. after start of the test:... bar Time:... :... Pressure loss:...bar Test pressure 60 min. after start of the test:... bar Time:... :... Pressure loss:...bar Test pressure 180 min. after start of the test:... bar Time:... :... Pressure loss:...bar Visual inspection carried out: Yes No Any leaking?: Yes No Test result: Signature date :... /... /... Place:... Installer signature: Others (pipes and/or fittings) Use separate sheet if needed: Person for the test signature:

19 1. General: Hereinafter purchaser ( Purchaser ) means an entity purchasing Products and services ( Products ) from Ingeniería Plástica del Sur s.l. ( Supplier ) or whose order for the Products is accepted by the Supplier These International Sales and Delivery Terms shall apply to all Products supplied by the Supplier to the Purchaser. They shall also apply to all future business even when no express reference is made to them Any deviating or supplementary conditions, especially Purchaser s general conditions of purchase and verbal agreements, shall only be applicable if accepted in writing by Supplier The written form shall be deemed to be fulfilled by all forms of transmission, evidence in the form of text, such as fax or Tenders: Tenders shall only be binding if they contain a specifically stated period of acceptance. 3. Scope of Delivery: Supplier s product range is subject to change The confirmation of order shall govern the scope and execution of the contract. 4. Data and documents: Technical documents such as drawings, descriptions, illustrations and data on dimensions, performance and weight as well as the reference to standards are for information purposes only. They are not warranted characteristics and are subject to change All technical documents shall remain the exclusive property of the Supplier and may only be used for the agreed purposes or as Supplier may consent. 5. Confidentiality: Each party shall keep in strict confidence all commercial or technical information relating to the business of the other party, of which it has gained knowledge in the course of its dealing with the other party. Such information shall neither be disclosed to third parties nor used for other purposes than those for which the information has been supplied. 6. Local Laws and Regulations: The Purchaser shall bring to the attention of the Supplier all local laws and regulations at the place of destination which bear connection with the execution of the contract and the adherence to relevant safety regulations and approval procedures. 7. Price of Products: The price of the Products shall be the price specified in separate written agreement or, if none, on the Supplier s order acknowledgement or, if none, on the Supplier s quotation or, if none, on the Supplier s price list. All prices quoted are valid for 14 days only or until earlier acceptance by the Purchaser Unless agreed otherwise, the prices shall be deemed quoted EXW (Incoterms 2000 basis) including standard packing. All supplementary costs such as the cost of carriage, insurance, etc., shall be borne by the Purchaser. The Purchaser shall also bear the costs of taxes, fees, duties, etc., connected with the contract If the cost of packing, carriage, insurance, fees and other supplementary costs are included in the tender price or contract price or are referred to specifically in the tender or confirmation of order, the Supplier reserves the right to revise their prices accordingly should any change occur in the relevant tariffs. 8. Terms of Payment: The Purchaser shall make payment in Euros and in the manner agreed by the parties without any deductions such as discounts, costs, taxes or dues. 9. Retention of Title: The Products shall remain the property of the Supplier until the Purchaser shall have settled all claims, present and future, which the Supplier may have against him. 10. Delivery: Terms of delivery shall be EXW, Incoterms The term of delivery shall commence as soon as the contract has been entered into, all official formalities such as import and payment permits have been obtained and all essential technical issues have been settled. The term of delivery shall be deemed duly observed when, upon its expiry, the Products are ready for despatch Any dates quoted for delivery of the Products are approximate only and the Supplier shall not be liable for any delay in delivery of the Products unless being in delay more than two weeks from the agreed approximate delivery date and having received the Purchaser s written notification. INTERNATIONAL SALES AND DELIVERY TERMS

20 Delivery is subjected to the following conditions, i.e. the term of delivery shall be reasonably extended: 11. Packing: a) If the Supplier is not supplied in time with the information necessary for the execution of the contract or if subsequent changes causing delays are made by the Purchaser. b) if the Supplier is prevented from performing the contract by force majeure. Force majeure shall equally be deemed to be any unforeseeable event beyond the Supplier s control which renders the Supplier s performance commercially unpractical or impossible, such as delayed or defective supplies from sub contractors labour disputes, governmental orders or regulations, shortages in materials or energy, serious disturbances in the Supplier s works, such as the total or partial destruction of plant and equipment breakdown of essential facilities, serious disruptions in transport facilities, e.g. impassable roads. c) if the Purchaser is in delay with the fulfilment of his obligations under the contract, in particular, if he does not adhere to the agreed conditions of payment or if he has failed to timely provide the agreed securities. If the Products are provided with additional packing over and above the standard packing, such packing shall be charged additionally. 12. Risk and property: Risk of damage to or loss of the Products shall pass to the Purchaser at the time of delivery. The Purchaser should insure the Products accordingly The property in the Products shall pass to the Purchaser upon the payment in full of the price of the Products Until the property in the Products passes to the Purchaser, the Purchaser shall hold the Products as the Supplier s fiduciary agent, and shall keep the Products separate and properly stored, protected and insured and identified as the Supplier s property, and shall not be entitled to dispose of the Products Until such time as the property of the Products passes to the Purchaser, the Supplier may at any time require the Purchaser to deliver up the Products to the Supplier and, if the Purchaser fails to do so forthwith, enter upon any premises of the Purchaser or any third party where the Products are stored and repossess the Products. 13. Carriage and Insurance: Unless agreed otherwise, the Purchaser shall bear the cost of carriage The Purchaser shall be responsible for transport insurance against damage of whatever kind. Even when such insurance is arranged by Supplier it shall be deemed taken out by the order of and for the account of the Purchaser and at his risk. 14. Inspection, Notification of Defects and Damages: The Products will be subject to normal inspection by the Supplier during manufacture. Additional tests required by the Purchaser shall be agreed upon in writing and shall be charged to the Purchaser It shall be a condition of the Supplier s obligation under the warranties stated hereinafter that Supplier be notified in writing by the Purchaser of any purported defect immediately upon discovery. Notice concerning weight, numbers or apparent defects is to be given latest within eight days from receipt of the Products, notice of other defects immediately latest within seven working days after discovery, in any event within 12 months of delivery Purchaser shall not dispose of allegedly defective Products until all warranty and/or damage claims are finally settled. At its request, defective Products are to be placed at Supplier s disposal At its request, the Supplier shall be given the opportunity to inspect the defect and/or damage, prior to commencement of remedial work, either itself or by third party experts In case of claimed defective Products, the Supplier may, at its option, replace or repair the Products free of charge or 15. Warranty: refund the price of the Products, but the Supplier shall have no further liability to the Purchaser. All Products manufactured by the Supplier are covered under a Liability Insurance Policy which shall be provided by the Supplier upon request. 16. Place of Performance and Jurisdiction: Place of performance for the Products shall be the Supplier s works from which the Products are dispatched Any civil action based upon any alleged breach of this contract shall be filed and prosecuted exclusively in the Courts of Granada, Spain. Supplier however reserves the right to file actions in any court having jurisdiction over controversies arising out of or in connection with the present contract The contract shall be governed by and constructed in accordance with the laws of Spain excluding UN Convention of International Sale of Products Without prejudice to clause 16.3 above, the Supplier reserves the right, at its own choice, to sue the Purchaser at the Purchaser s general place of jurisdiction. Ingeniería Plástica del Sur S.L.

21 Notes

22 Certificates LNEC Certificate

23 plomyclick fittings

24 Certificates plomyclick fittings + plomylayer pipe System

25 plomyclick fittings + plomypex pipe System

26 Certificates plomylayer pipes

27 plomypex pipes

28 Certificates plomyfloor underfloor heating system 16mm

29 plomyfloor underfloor heating system 20mm

30 Certificates plomypex-eval pipes

31 Ukrainian Certificates

32 Certificates Ukrainian Certificates

33 South African Certificates

34 ER ER Building Solutions, meeting expectations INGENIERÍA PLÁSTICA DEL SUR, S.L. Autovía A-92, Km. 209 E MORALEDA DE ZAFAYONA GRANADA SPAIN Tel Fax IM

Flexible & Intelligent

Flexible & Intelligent Flexible & Intelligent The flexible copper tube cuprotherm CTX tubes are copper tubes with a firmly adherent coating. Due to their structure they can be easily processed and are characterized by a flexibility

More information

METHODS TO PREVENT THE PREMATURE ACTIVATION OF RELIEF DEVICES ON TRANSPORT TANKS

METHODS TO PREVENT THE PREMATURE ACTIVATION OF RELIEF DEVICES ON TRANSPORT TANKS METHODS TO PREVENT THE PREMATURE ACTIVATION OF RELIEF DEVICES ON TRANSPORT TANKS IGC Doc 184/14/E EUROPEAN INDUSTRIAL GASES ASSOCIATION AISBL AVENUE DES ARTS 3-5 B 1210 BRUSSELS Tel: +32 2 217 70 98 Fax:

More information

MATERIALS FOR PLUMBING SYSTEMS FITTING AND INSTALLATION GUIDE

MATERIALS FOR PLUMBING SYSTEMS FITTING AND INSTALLATION GUIDE MATERIALS FOR PLUMBING SYSTEMS FITTING AND INSTALLATION GUIDE THINK GLOBALLY, ACT LOCALLY CONTENTS Propex DZR fittings and pex 2 Why depend on Propex hot and cold piping system 3 Cross linked polyethylene

More information

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC 157-20067 1 PURPOSE 1.1 The purpose of this standard is to establish an acceptable standard

More information

SPECIFICATIONS & INSTALLATION GUIDE ANOTHER QUALITY PRODUCT BY FORZA GLOBAL WATER CRIMP EDITION: 0001

SPECIFICATIONS & INSTALLATION GUIDE ANOTHER QUALITY PRODUCT BY FORZA GLOBAL WATER CRIMP EDITION: 0001 WATER CRIMP TM SPECIFICATIONS & INSTALLATION GUIDE ANOTHER QUALITY PRODUCT BY FORZA GLOBAL EDITION: 0001 2 WATER CRIMP FORZA GLOBAL are the manufacturers and distributors of FORZA PE-Xa PIPING Systems

More information

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL Company Registered Office: Crown House, Stockport, Cheshire, SK13RB No. 850 0700 67 Registered in England and Wales No. 05058855

More information

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures MINT-0289-XX TABLE OF CONTENTS Limited Warranty... 3 User Responsibility... 3-4 General Service... 4 Safety Precautions.... 5 Physical Dimensions..

More information

AIRMASTER SERIES RF AUTOMATIC DEWATERING VALVES. For the purging of water from compressed air systems WHERE DO YOU NEED AUTOMATIC DEWATERING VALVES

AIRMASTER SERIES RF AUTOMATIC DEWATERING VALVES. For the purging of water from compressed air systems WHERE DO YOU NEED AUTOMATIC DEWATERING VALVES R SERIES RF AUTMATIC DEWATERING VALVES For the purging of water from compressed air systems The series RF is a high capacity automatic dump valve specifically designed to continuously purge water from

More information

M03 WUNDATRADE. Heat Pump Manifold. Before you start: Check the contents. Optional. ...a division of WUNDA GROUP PLC

M03 WUNDATRADE. Heat Pump Manifold. Before you start:  Check the contents. Optional. ...a division of WUNDA GROUP PLC Before you start: Check the manifold box contents against the list below. Check the contents Flow gauges 1. Bar assembly with manual return valves 2. 2 x Auto air vent & drain hose attachments Optional

More information

STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL)

STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL) STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL) TEE (HOT TAPPING MATERIAL) S-04-02-040 Page 1 of 7 1.0 SCOPE This specification covers the basic requirements for the design, manufacture and supply

More information

453 Series Steam Heated Vaporizing Regulator

453 Series Steam Heated Vaporizing Regulator ADI 0453A Certified ISO 9001:2000 453 Series Steam Heated Vaporizing Regulator INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls Corporation

More information

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO Instructions for Use Plug connection for medical gas and vacuum acc. to DIN 13260-2 / 2004 DIN EN ISO 9170-1 Table of Contents Page 1. MANUFACTURER S DATA... 3 2. INTRODUCTION... 4 3. APPLICATION... 5

More information

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2) UN-GTR PART A INSERTION Stand 09.02.2011, 17:20 Uhr A.3.3 HYDROGEN STORAGE SYSTEM The hydrogen storage system consists of all components that form the primary pressure boundary of the stored hydrogen in

More information

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions PLAQUE MFM0680 UNDERWATER LIGHT Operating Instructions CONTENTS Preface... 3 Features... 3 Precautions... 3 Controls and Connectors... 4 Underwater Light PLAQUE MFM0680... 4 Power Supply Unit MPS021000

More information

FLANGED TWO-PIECE BALL VALVES

FLANGED TWO-PIECE BALL VALVES INTRODUCTION This instruction manual includes installation, operation, and maintenance information for FNW flanged split-body ball valves. This manual addresses lever operated ball valves only. Please

More information

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar Instruction manual for high purity gas pigtails 200 bar / 300 bar Contents Contents... 2 1. Preface... 3 1.1 Overview... 3 1.2 General... 3 1.3 Intended use... 4 1.4 Personnel requirements... 4 2. For

More information

MODEL CALIBRATION GAS DELIVERY SYSTEM

MODEL CALIBRATION GAS DELIVERY SYSTEM MODEL 1200-26 CALIBRATION GAS DELIVERY SYSTEM Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 MODEL 1200-26 CALIBRATION GAS DELIVERY SYSTEM APPLICABILITY & EFFECTIVITY This

More information

D Series Air and Water Kit Part# 02550

D Series Air and Water Kit Part# 02550 D Series Air and Water Kit Part# 02550 Unpacking Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you undamaged.

More information

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL Company Registered Office: Crown House, Stockport, Cheshire, SK13RB No. 850 0700 67 Registered in England and Wales No. 05058855

More information

Series 8500 Expansion Compensators. Catalog 674H

Series 8500 Expansion Compensators. Catalog 674H Series 8500 Expansion Compensators Catalog 674H 500 Laminated Bellows Expansion J Series 8500 on Joints Expansion Compensators Sizes 3/4" through 4" Threaded, welded, flanged and grooved steel pipe joints

More information

SPECIFICATIONS & INSTALLATION GUIDE ANOTHER QUALITY PRODUCT BY FORZA GLOBAL WATER CRIMP EDITION: 0001

SPECIFICATIONS & INSTALLATION GUIDE ANOTHER QUALITY PRODUCT BY FORZA GLOBAL WATER CRIMP EDITION: 0001 WATER CRIMP TM SPECIFICATIONS & INSTALLATION GUIDE ANOTHER QUALITY PRODUCT BY FORZA GLOBAL EDITION: 0001 2 WATER CRIMP FORZA GLOBAL are the manufacturers and distributors of FORZA PE-Xa PIPING Systems

More information

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS THIS BOOKLET CONTAINS PROPRIETARY INFORMATION OF ADVANCED SPECIALTY GAS EQUIPMENT CORP. AND IS PROVIDED TO THE PURCHASER SOLELY FOR USE IN CONJUNCTION WITH MODEL

More information

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR S S F U SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR MACHINERY DIVISION OWNER S MANUAL UNIT INSTRUCTIONS Please follow all SSFU Safety Instructions. Contact your Duro Dyne Tech Service if you have

More information

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

Installation, Operation and Maintenance Instructions Buffer Vessel OM006 Installation, Operation and Maintenance Instructions Buffer Vessel OM006 Calorifiers Heat Exchangers Pressurisation Units Sales Tel: 01457 835700 Sales Fax: 01457 832700 E-mail: sales@gmsthermal.co.uk

More information

Instrument Operating Manual

Instrument Operating Manual Instrument Operating Manual INDEX NO. SUBJECT PAGE 1 INFORMATION 3 2 SAFETY 4 3 INTENDED USE 4 4 COMMISSIONING & OPERATION 5 5 MAINTENANCE 6 2 INFORMATION The pressure gauges described in the operating

More information

Standard Terms and Conditions

Standard Terms and Conditions Standard Terms and Conditions Introduction 1. In these terms: 'MIDWICH LIMITED' means Midwich Limited ABN 82 082 281 543; 'Products' means the products and / or services supplied, or proposed to be supplied,

More information

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions Compact Triple Cabinet Outlet Station Model 6258-1 Installation and Operating Instructions The Porter Compact Triple Outlet Station (6258-1) provides a quick, safe, and reliable method of connection to

More information

92831 TEL: (714) FAX:

92831 TEL: (714) FAX: Document No. 1800-75 Respiration Test Chamber Copyright 2010 Terra Universal Inc. All rights reserved. Revised September 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA

More information

FLANGED TWO-PIECE BALL VALVES

FLANGED TWO-PIECE BALL VALVES INTRODUCTION This instruction manual includes installation, operation, and maintenance information for FNW flanged split-body ball valves. This manual addresses lever operated ball valves only. Please

More information

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company Installation and Operating Instructions DANGER: DO NOT MIX CHEMICALS! The Acid-Rite ph Adjustment System is designed for use with Axiall

More information

Price Schedule # Effective: MAy 5, 2014

Price Schedule # Effective: MAy 5, 2014 INTERNATIONAL Malleable Pipe s & Unions Schedule #514 Effective: MAy 5, 2014 90 ELBOWS 45 ELBOWS 1/8 50 600 7 9.29 12.12 1/4 35 420 11 8.85 12.12 3/8 90 360 16 8.85 12.12 1/2 50 200 26 6.63 8.01 3/4 35

More information

REFERENCE SPECIFICATION FOR END

REFERENCE SPECIFICATION FOR END TITLE SPECIFICATION FOR END CONNECTORS AND INSULATING DATE: DECEMBER 2003 SLEEVES PAGE: 1 OF 18 TABLE OF CONTENTS Page FOREWORD... 2 INTRODUCTION... 3 1 SCOPE... 3 2 CONSTRUCTIONAL REQUIREMENTS... 3 2.1

More information

ASSE International Product (Seal) Listing Program

ASSE International Product (Seal) Listing Program ASSE International Product (Seal) Listing Program ASSE 1070-2015 / ASME A112.1070-2015 / CSA B125.70-15 Performance Requirements for Water Temperature Limiting Devices Manufacturer: Contact Person: E-mail:

More information

b) Submission of Crew list and arrival details (no later than 2 weeks prior to charter)

b) Submission of Crew list and arrival details (no later than 2 weeks prior to charter) 1) The Contract By signing this contract you agree to these conditions. A contract exists as soon as Simpson Yacht Charter has received the completed booking form, duly signed by the Charterer, and the

More information

J Air and Water Kit Instructions Part# 02584

J Air and Water Kit Instructions Part# 02584 J Air and Water Kit Instructions Part# 02584 Unpacking Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you

More information

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual 8 Executive Drive P.O. Box 2105 Toms River, NJ 08754 (732) 244-0010 (800) 337-3762 fax (732) 244-8140 www.permapure.com info@permapure.com

More information

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions PORTER Parker Hannifin Corporation Porter Instrument Division 245 Township Line Rd. P.O. Box 907 Hatfield, PA 19440-0907 USA (215) 723-4000 / fax (215) 723-5106 Compact Triple Cabinet Outlet Station Model

More information

The Duopex Gas. to make every job quick and easy. it provides a revolutionary alternative for the professional plumber and 02_DUOPEX GAS GAS MANUAL

The Duopex Gas. to make every job quick and easy. it provides a revolutionary alternative for the professional plumber and 02_DUOPEX GAS GAS MANUAL duopex gas manual The Duopex Gas pipe and fitting system is designed to make every job quick and easy. it provides a revolutionary alternative for the professional plumber and gasfitter. 02_DUOPEX GAS

More information

The balance of the charter fee will be paid to Cloud Nine Yacht Charters not less than 28 days before the start of the period of charter.

The balance of the charter fee will be paid to Cloud Nine Yacht Charters not less than 28 days before the start of the period of charter. Terms And Conditions 1. CONDITIONS OF PAYMENT 1.1 The Charter Owner / Operator (Cloud Nine Yacht Charters) will let the yacht and the Charter Customer (B) will hire the Vessel(s) (C) for the Period of

More information

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES THIS BOOKLET CONTAINS PROPRIETARY INFORMATION OF ADVANCED SPECIALTY GAS EQUIPMENT CORP. AND IS PROVIDED TO THE PURCHASER SOLELY FOR USE

More information

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804

3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804 Model 3801 Model 3804 3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains

More information

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions VS18/26 with PROFINET and EtherNet/IP Interface ATEX Installation Instructions INDEX 1. INTENDED USAGE 3 2. OPERATING MANUAL ATEX 4 2.1 General conditions 4 2.2 Installation 5 2.3 Operating 5 2.4 Failures

More information

92831 TEL: (714) FAX:

92831 TEL: (714) FAX: Document N0. 1800-03 Copyright 2010 Terra Universal Inc. All rights reserved. Revised Sept. 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX:

More information

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger OM008 Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger The operating and maintenance instructions contained within this package are for Pacific water/water

More information

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

3 UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC. 3" UC-3000 (76.2 mm) Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual DOUBLE E COMPANY, INC. 319 Manley Street, West Bridgewater, MA 02379 U.S.A. Tel: (508) 588-8099 /

More information

Gas plug-in hose, straight-through form. Instructions for Use. suitable for gas socket model G2019T, G2016T. G2023 from 01/1990.

Gas plug-in hose, straight-through form. Instructions for Use. suitable for gas socket model G2019T, G2016T. G2023 from 01/1990. Gas plug-in hose, straight-through form Instructions for Use suitable for gas socket model G2019T, G2016T Model Year built: G2023 from 01/1990 en_int Gas plug-in hose, straight-through form 2 from 12 Table

More information

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician. USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. RECEIVING / INSPECTION Remove the Precision Medical,

More information

NIT LIMITED NO. NC-105-P-SCS-NOCB CYLINDERS & REGULATORS

NIT LIMITED NO. NC-105-P-SCS-NOCB CYLINDERS & REGULATORS NIT LIMITED NO. CYLINDERS & REGULATORS NATIONAL INSTITUTE OF SCIENCE EDUCATION & RESEARCH JATNI CAMPUS, P.O.: JATNI, Khurdha-752050 Tender Notice No. NIT Limited NO. Sealed Tenders are invited on behalf

More information

BCGA GUIDANCE NOTE 17

BCGA GUIDANCE NOTE 17 BCGA GUIDANCE NOTE 17 BCGA POLICY AND GUIDANCE FOR THE SAFE FILLING OF THIRD-PARTY OWNED AND / OR MAINTAINED TANKS Revision 2: 2013 BCGA GUIDANCE NOTE 17 BCGA POLICY AND GUIDANCE FOR THE SAFE FILLING OF

More information

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1. Spilt body Flange ball valve TC-205MFF-PN1640 Series PED Category I,II TC-205MFF-PN1640 User Manual English Version Use for company in Europe who will place the product on the market, please amend which

More information

GX SYSTEM. Technical documentation 0756EN

GX SYSTEM. Technical documentation 0756EN GX SYSTEM Technical documentation 0756EN GX System SUMMARY 1 GX System 1 Advantages and features 1 Technical features - GX connection 2 Technical features - Pipes 6 Technical features - Fittings 8 Technical

More information

Geopress. Instructions for Use. Year built: from 01/2004 en_int

Geopress. Instructions for Use. Year built: from 01/2004 en_int Geopress Instructions for Use Year built: from 01/2004 en_int Geopress 2 from 26 Table of contents Table of contents 1 About these instructions for use 4 1.1 Target groups 4 1.2 Labelling of notes 4 1.3

More information

Declaration of Conformity as per Directive 97/23/EC

Declaration of Conformity as per Directive 97/23/EC Declaration of Conformity as per Directive 97/23/EC The manufacturer declares that:, 47906 Kempen, Germany Continuous, inline sampling valves Series 27f, with packing Operate with either; Star lever, or

More information

ROPV R40 E Series User Manual

ROPV R40 E Series User Manual HARBIN ROPV INDUSTRY DEVELOPMENT CENTER ROPV R40 E Series User Manual For Use with the Following ROPV Pressure Vessel Models: R40 300E R40 450E Headquarters Tel:(+86)451-82267301 Fax:(+86)451-82267303

More information

623 Series Dome Load Regulators

623 Series Dome Load Regulators ADI 3202C Certified ISO 9001 623 Series Dome Load Regulators INSTALLATION AND OPERATION INSTRUCTIONS This Equipment is intended to be installed and operated by trained personnel. Before Installing or Operating,

More information

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar EN - english Instructions for installation and operation Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar Dear customer, Thank you for deciding in favour of the METPOINT

More information

Medical Gas Solutions

Medical Gas Solutions WHN YOU ND from OKRING okring Technology, C offers a patented, permanent, axially swaged tube fitting. This technology for medical gas applications has been approved by NFP 99-005 (Paragraph 5..0.7 (4)).

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

Gas Welding Hoses and connections, the weak link

Gas Welding Hoses and connections, the weak link Gas Welding Hoses and connections, the weak link By Leif Andersen, Technical Product Manager Welding, WSS Regulators with flashback arrestors and the shank with its welding or cutting attachment are made

More information

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers MASS-STREAM TM Instruction Manual D-6200 Analog Mass Flow Meters / Controllers Doc. No.: 9.17.112A Date: 17-03-2017 ATTENTION Before installing and operating the instrument it is strongly recommended that

More information

Installation Instructions JATCO Environmental Protection Tank Model J-7000

Installation Instructions JATCO Environmental Protection Tank Model J-7000 Installation Instructions JATCO Environmental Protection Tank Model J-7000 The JATCO Environment Tank must be installed at a level which will allow the waste liquids to be disposed of to gravity flow into

More information

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914 Installation, Operating and Maintenance Instructions V914 Cast Iron Flanged Swing Check Valve V914 THE PRESSURE EQUIPMENT DIRECTIVE 97/23/EC and CE MARKING The Pressure Equipment Regulations 1999 (SI 1999/2001)

More information

REFER TO AQUATHERM TECHNICAL BULLETIN A-AQTTB FOR ADDITIONAL INFORMATION AND SAFETY PRECAUTIONS

REFER TO AQUATHERM TECHNICAL BULLETIN A-AQTTB FOR ADDITIONAL INFORMATION AND SAFETY PRECAUTIONS Aquatherm Standard Pressure Testing Procedure Aquatherm offers an extensive warranty to protect against damages caused by failure from manufacturer s defect. Aquatherm requires that all installations be

More information

Modular skylight warranty

Modular skylight warranty Modular skylight warranty Specific limited product warranty 10 year limited warranty (a) (b) (c) VELUX insulating glass For a period of (10) ten years from the date of purchase, VELUX warrants to the end-user

More information

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15 ASSEMBLING PROCEDURE AND VALVE MAINTENANCE 1.0.... Safety Information 2.0.. INTRODUCTION 3.0 VARIATIONS 4.0..ASSEMBLING PROCEDURE FOR THE STEM 5.0 ASSEMBLING PROCEDURE FOR OUTLET CONNECTIONS 6.0 PROCEDURE

More information

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel OM006 Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel The operating and maintenance instructions contained within this package are for standard mild steel buffer vessels

More information

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES PRESSURE REGULATORS ALL MEDICAL GASES In this section we propose our pressure regulators (FM series, MU and MERCURY ) and our Rs flowmeters for applications other than oxygen therapy (presented in the

More information

Operating Instruction Manual for Liquid Nitrogen Containers. CRY/CRYC Series. Hagavish st. Israel Tel: , Fax:

Operating Instruction Manual for Liquid Nitrogen Containers. CRY/CRYC Series. Hagavish st. Israel Tel: , Fax: Operating Instruction Manual for Liquid Nitrogen Containers CRY/CRYC Series Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.12.14 TO USER Thank You! You have just purchased

More information

for the of and the EM55-1

for the of and the EM55-1 Operating Manua al for the Tapping Points of the EM55-1/EM55-2/EM55-3/ /EM55-4 series and the EE55-1/EE55-2/EE55-3/EE55-4 series EM55-1 Contents Contents... 2 1. Introduction... 3 1.1 General... 3 1.2

More information

Installation, operation & maintenance manual - original version

Installation, operation & maintenance manual - original version Installation, operation & maintenance manual - original version AVK gate valves for water and wastewater Series 01, 02, 06, 12, 15, 18, 20, 26, 32, 33, 36, 38, 50, 55 and 636 COPYRIGHT AVK GROUP A/S 2018

More information

tubepress press procedure

tubepress press procedure tubepress press procedure tubepress 15mm up to 35mm tubepress 15 mm up to 35 mm 1. The tube ends must be clean with no scratches or grooves. Remove end caps. Cut tube to length. 2. Deburr tube inside and

More information

Model Portable Eyewash

Model Portable Eyewash INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 7601.37 Portable Eyewash

More information

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number 3M Water Filtration Products FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number 56123-06 Installer: Please leave this manual with owner/operator. End User: Please retain for

More information

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions PLAQUE MFM18240 UNDERWATER LIGHT Operating Instructions CONTENTS Preface... 3 Features... 3 Precautions... 3 Controls and Connectors... 4 Underwater Light PLAQUE MFM18240... 4 Power Supply Unit MPS061000

More information

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX Installation Instructions JATCO Environmental Protection Tank Model J-5000CX The JATCO Environment Tank must be installed at a level which will allow the waste liquids to be disposed of to gravity flow

More information

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems Oxygen Concentrator Installation and Operation Manual ClearWater Tech, LLC. Integrated Ozone Systems 850-E Capitolio Way, San Luis Obispo, Ca 93401 805-549-9724 Fax: 805-549-0306 E-mail: service@cwtozone.com

More information

Declaration of Conformity as per Directive 97/23/EC

Declaration of Conformity as per Directive 97/23/EC Declaration of Conformity as per Directive 97/23/EC The manufacturer declares that:, 47906 Kempen, Germany Multi-way diverting valves Series 29a and Series 29b, with packing with lever 1. The valves are

More information

HYDROSTATIC LEAK TEST PROCEDURE

HYDROSTATIC LEAK TEST PROCEDURE This information is proprietary and shall not be disclosed outside your organization, nor shall it be duplicated, used or disclosed for purposes other than as permitted under the agreement with Kinetics

More information

4-in-1 Professional Inflator Kit

4-in-1 Professional Inflator Kit 4-in-1 Professional Inflator Kit Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644 Technical Services: Tel: (00) 31-9312 / Fax: (00) 791-5500 Model C Pipe Line Strainer 6, & 10 Inch (150, & 250) 250 psi (17,2) General Description The welded steel body Model C Pipe Line Strainers (Ref.

More information

Accu-Tab PowerBase 3012AT by Axiall Corporation

Accu-Tab PowerBase 3012AT by Axiall Corporation Accu-Tab PowerBase 3012AT by Axiall Corporation Installation and Operating Instructions DANGER: DO NOT MIX CHEMICALS! The PowerBase 3012AT chlorinator system is designed for use with Axiall Corp. approved

More information

Nitrogen Supply System

Nitrogen Supply System ATMOSCOPE Nitrogen Supply System NS500 Users Guide Copyright 2001 EDSYN, INC. ATMOSCOPE Nitrogen Supply Systems TABLE OF CONTENTS Introduction............................. 3 General Information.......................

More information

CSIR-NATIONAL GEOPHYSICAL RESEARCH INSTITUTE (COUNCIL OF SCIENTIFIC & INDUSTRIAL RESEARCH) Uppal Road, Hyderabad (Telangana.

CSIR-NATIONAL GEOPHYSICAL RESEARCH INSTITUTE (COUNCIL OF SCIENTIFIC & INDUSTRIAL RESEARCH) Uppal Road, Hyderabad (Telangana. CSIR-NATIONAL GEOPHYSICAL RESEARCH INSTITUTE (COUNCIL OF SCIENTIFIC & INDUSTRIAL RESEARCH) Uppal Road, Hyderabad - 500 007 (Telangana.) India FAX: +91-40-27012486, 27012533, e-mail: purchase@ngri.res.in

More information

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the The Silencer, connected to the exhaust port of a device, suppresses the exhaust noise. The Silencer displays an excellent noise suppression effect. Three types are available for your selection. The element

More information

>B< Push Technical Brochure

>B< Push Technical Brochure COPPER MULTILAYER PE-X PB CARBON STEEL >B< Push Technical Brochure Rev 1.15 Contents Abbreviation Key Overview...2 Key Benefits...4 Tube Compatibility...6 Installation Guide...8 Demounting Tool...9 EPDM

More information

AUTHENTIC IBN NAWAAL 50 Dunkard Church Road Stockton, NJ Tele: (609) Fax: (609)

AUTHENTIC IBN NAWAAL 50 Dunkard Church Road Stockton, NJ Tele: (609) Fax: (609) AUTHENTIC IBN NAWAAL 50 Dunkard Church Road Stockton, NJ 08559 Tele: (609) 577-1976 Fax: (609) 397-1369 Email: IBNNAAWAL@gmail.com COOLED SEMEN BREEDING AGREEMENT THIS COOLED SEMEN BREEDING AGREEMENT is

More information

SERVICE LETTER WARRANTY CONDITIONS FOR ROTAX

SERVICE LETTER WARRANTY CONDITIONS FOR ROTAX SERVICE LETTER WARRANTY CONDITIONS FOR ROTAX ENGINE TYPES 912 AND 914 (SERIES) AND 2-STROKE AIRCRAFT ENGINES Repeating symbols: Please, pay attention to the following symbols throughout this document emphasizing

More information

Type BBS-03, BBS-05, BBS-06, BBS-25

Type BBS-03, BBS-05, BBS-06, BBS-25 Type BBS-03, BBS-05, BBS-06, BBS-25 Sterile connection elements Sterile Verbindungselemente Raccords union stériles Operating Instructions Bedienungsanleitung Manuel d utilisation 1. THE OPERATING INSTRUCTIONS

More information

International Civil Aviation Organization DANGEROUS GOODS PANEL (DGP) MEETING OF THE WORKING GROUP OF THE WHOLE. Montreal, 18 to 22 April 2005

International Civil Aviation Organization DANGEROUS GOODS PANEL (DGP) MEETING OF THE WORKING GROUP OF THE WHOLE. Montreal, 18 to 22 April 2005 International Civil Aviation Organization WORKING PAPER 24/3/05 DANGEROUS GOODS PANEL (DGP) MEETING OF THE WORKING GROUP OF THE WHOLE Montreal, 18 to 22 April 2005 Agenda Item 2: Development of recommendations

More information

TENDER FOR THE SUPPLY OF MEDICAL OXYGEN AND NITROUS OXIDE GASES CYLINDERS FOR ONE YEAR.

TENDER FOR THE SUPPLY OF MEDICAL OXYGEN AND NITROUS OXIDE GASES CYLINDERS FOR ONE YEAR. L E S 1 Government of Karnataka BELGAUM INSTITUTE OF MEDICAL SCIENCES, BELGAUM AUTONOMOUS INSTITUTE (Registered Under Societies Registration Act) Dr. B. R. Ambedkar Road, Belgaum 590 001. Phone No: 0831-2420320,

More information

Media-Isolated Mag Plus Probe Low Pressure-ISO Kit

Media-Isolated Mag Plus Probe Low Pressure-ISO Kit Manual No: 577013-975 Revision: B Media-Isolated Mag Plus Probe Low Pressure-ISO Kit Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but

More information

CastCreations PRODUCT DESCRIPTION. Redwood Stump Fire Pit Item #: C1002. CastCreations Ph: Aurora, Utah

CastCreations PRODUCT DESCRIPTION. Redwood Stump Fire Pit Item #: C1002. CastCreations Ph: Aurora, Utah CastCreations PRODUCT DESCRIPTION Redwood Stump Fire Pit Item #: C1002 Manufactured by: Questions or Concerns? CastCreations Ph: 1-435-529-3350 PO Box 155 E-mail: info@ccfandw.com Aurora, Utah UNIT COMPONENTS

More information

453 Series Steam Heated Vaporizing Regulator

453 Series Steam Heated Vaporizing Regulator ADI 0453B Certifi ed ISO 9001 453 Series Steam Heated Vaporizing Regulator INSTALLATION AND OP ER A TION IN STRUC TIONS Before Installing or Operating, Read and Comply with These Instructions Controls

More information

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5 operating Instructions manual MUELLER Mega-Lite Drilling Machine table of contents PAGE Equipment 2 Operating Instructions 3-4 Parts Information 5 Travel Charts 6-11! WARNING: 1. Read and follow instructions

More information

Simple to install connection fails. The Talbot Pushfit fitting is pressure rated PN 16.

Simple to install connection fails. The Talbot Pushfit fitting is pressure rated PN 16. Talbot Pushfit Talbot Pushfit - Fittings for Water Pipe Talbot Grippa Universal Service Connector The Talbot Pushfit connection is a tried and tested method of connecting low, The Talbot Grippa is a universal

More information

Accu-Tab Systems 1000 Series by Axiall Corporation

Accu-Tab Systems 1000 Series by Axiall Corporation Accu-Tab Systems 1000 Series by Axiall Corporation Installation and Operating Instructions Model 1050 DANGER: DO NOT MIX CHEMICALS! The Accu-Tab chlorinator is designed for use with Axiall approved tablets

More information

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP LIMITED WARRANTY Getz Equipment Innovators warrants its products, and component parts of any product manufactured by

More information

Installation and Maintenance Instruction Manual

Installation and Maintenance Instruction Manual Installation and Maintenance Instruction Manual Bi-metal Thermometer Model A and E in a configuration - pursuant to ASME B40.200: ##=E#=### or ##=ERT#=### - pursuant to EN 13190: ###=A#=### or ##=ART#=###

More information

Giacomini Multigas System 0543EN November 2017 Multilayer pipe G999

Giacomini Multigas System 0543EN November 2017 Multilayer pipe G999 Multigas System General info Standards UNI 7129-1:2015 and UNI 11344:2014 (concerning the features of the multilayer gas pipe and its installation in homes) indicate that the multilayer system can be used

More information

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC # E X R A D I N Spherical Ion Chambers A3. A4 REF 92717. 92715 R DOC #80360-00 E X R A D I N Spherical Ion Chambers A3. A4 REF 92717. 92715 STANDARD IMAGING INC. 7601 Murphy Drive Middleton, WI 53562 TEL

More information