Domestic and Commercial LPG cylinders instalations
|
|
- Gabriel Mason
- 6 years ago
- Views:
Transcription
1 Domestic and Commercial LPG cylinders instalations Kosan Crisplant offers a wide range of high quality products for propane and butane domestic and commercial networks, such as: Automatic Switches, Pressure Regulators The range Kosan Crisplant is offering is complete and matches several specifications and different demands from various markets. Nevertheless, if you do not find what you need on the following pages, we kindly ask you to contact us. We will do our best to provide the best solution for your need. For proper support contact one of the KC offices closest to your location. and Pressure Limiters These types of products are typically necessary for cylinder installations for domestic / recreational use as well as for commercial use. There is available a range for Butane and other range for Propane. Please keep in mind that for a correct selection, the composition of LPG mixture and necessary pressures to be delivered should be known. All laws and local standards should always be kept in min before installation. LPG equipments failures or improper use may cause dangerous situations such as: Too high a pressure downstream the regulator Regulator gas leak Too low a pressure downstream the regulator Damage or accident as consequence of previous situations.
2 Automatic Change Over with Indicator and Accessories The automatic change-over ensures a continuous supply of gas to cylinder installations (more than one) switching automatically from an empty cylinder to a full one. An indicator shows when this happens. It assure also the first stage pressure reduction. Automatic Change Over for Propane kg/h Cylinder 1,5 bar 20 x 1,5 ISO kg/h 1,5 bar (MxMxM) bar kg/h 1,5 bar Service indicator Service indicator for Automatic Change Over 8Kg/h Propane Manometer for Automatic Change Over Manometer 0-1,5 bar for Propane Automatic Change Over Manometer 0-3 bar for Propane Automatic Change Over 20 x 1,5 ISO Æ 13 Toric joint & igh and Fix Pressure Regulators The high and fix pressure regulators are usually installed downstream the cylinders or tank. It ensures the first stage pressure regulation. igh and Fix Pressure Regulators 1st stage regulation kg/h Cylinder or tank 1,5 bar 20 x 1,5 ISO Kg/h kg/h 3/4 x 3/ kg/h 3/4 x 20x1,5 ISO - V
3 Pressure Limiters The pressure limiters are safety devices installed downstream the 1st stage regulation. It protects the installation from excessive pressure if the first stage fails. Pressure Limiters kg/h Downstream the 1st Kg/h stage regulation 1,75 bar 20 x 1,5 ISO Kg/h 3/4 x 3/ Safety Regulators The safety regulators are normally installed after the 1st stage regulator and immediately before the gas meters or burners. They have three different functions: valve, pressure reduction, safety device and cutting the gas supply to the network if the pressure becomes lower than normal due a gas leakage. Safety Regulators kg/h 0,5 to 1,75 bar x 1,5 ISO - (20x1,5 ISO) x 7/8 Floating Flange kg/h x 1,5 ISO kg/h /07 12 kg/h 3/4 x 3/
4 Low and Fix Pressure Regulators The low and fix pressure regulators should be installed downstream the 1st stage regulation. They have the function of making the final gas pressure regulation to the appliance conditions & Low and fix pressure regulators 2nd Stage regulation Kg/h Downstream 1st stage regulation x 1,5 ISO x 1,5 ISO Kg/h x 1,5 ISO x 1,5 ISO kg/h 3/4 x 3/ & 18507/07 igh and Adjustable Pressure Regulators with Manometer The high and adjustable pressure regulator with manometer allows the end user to regulate the pressure from 0 to 3 bars. igh and adjustable pressure regulator with manometer Part Number Flow kg/h Cylinder Kg/h or tank 0-3 bar 20 x 1,5 ISO An incorporated manometer permanently shows the pressure value setting. 8785/2 & 13260/34 106
5 Low and Adjustable Pressure Regulators with Manometer The low and adjustable pressure regulator with manometer allows the end user to regulate the pressure from 0 to 0,6 bar. An incorporated manometer permanently shows the pressure value setting. Low and adjustable pressure regulator with manometer Kg/h Garrafa ou 14585/02 Reservatório 0-0,6 bar 0-0,3 bar 20 x 1,5 ISO 12610/07 12 Kg/h 0-0,3 bar 3/4 x 3/ _01 107
6 BUTANE RANGE Automatic Change Over with indicator and Accessories See the description of automatic change-over to Propane. The difference is related to the capacity (flow) and regulation pressures. Automatic Change Over for Butane (Butane) ,6 Kg/h Cylinder x 1,5 ISO (MxMxM) Manometer for Butane Automatic Change Over 13 Toric joint Fix Pressure Regulators See the description of high and fix pressure regulators, safety regulators and low and fix pressure regulators. The difference is related to the capacity (flow) and regulation pressures.. Fix pressure regulators Safety regulators 14570/03 2,6 Kg/h Cylinder x 1,5 ISO Or tank 14380/ ,1 to 0,6 20 x 1,5 ISO bar - (20x1,5 ISO) x 7/8 Floating Flange Kg/h 3/4 x 3/ / /
7 Kosan Crisplant a/s P.O. Pedersens Vej 22 DK-8200 Aarhus N Denmark Tel Fax sales@kosancrisplant.com service@kosancrisplant.com Worldwide sales of high-quality gas components ProSupply Centre Denmark: Tel ProSupply Centre Portugal: Tel prosupply@kosancrisplant.com Rev. 0 // March 2013
Unlimited possibilities. Get started in no time
Unlimited possibilities The patented KCFiLL machine is designed by Kosan Crisplant s engineers for easy, safe and accurate LPG filling, and offers the best value for money on the market for low-capacity
More informationISO INTERNATIONAL STANDARD. Small craft Liquefied petroleum gas (LPG) systems
INTERNATIONAL STANDARD ISO 10239 Second edition 2008-02-15 Small craft Liquefied petroleum gas (LPG) systems Petits navires Installations alimentées en gaz de pétrole liquéfiés (GPL) Reference number ISO
More informationThe only high-speed filling system for LPG cylinders in the world
GENERAL DESCRIPTION The only high-speed filling system for LPG cylinders in the world www.flexspeed.info All position numbers in the following description refer to the drawing FLEX- SPEED LAYOUT. The core
More informationAbout. providing superior performance and reliability. Bromic regulators are AGA or UL144 approved.
REGULATORS 1 About Bromic Plumbing & Gas provide a wide variety of regulators to suit applications from recreational to professional, in both Natural Gas & LPG (propane). Our range of regulators includes
More informationOIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply
OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply 4.1.1 General The primary function of a system for handling fuel oil is to transfer oil from the storage tank to the oil burner at specified conditions
More informationVaporizer Technique. FAS Flüssiggas-Anlagen GmbH
Cover_Booklet_Premium_ Poland Folder\Links\Cover_ Poland.psd One of the best assorted and largest stock of equipments of any kind destined for all industrial LPG applications within Europe. With more than
More informationRE: PROPANE SYSTEM & REGULATOR TESTING/INSPECTION PROCEDURE
March 22, 2013 RE: PROPANE SYSTEM & REGULATOR TESTING/INSPECTION PROCEDURE Regulators: Symptom: Pressure Drop Cause: External leaks detected at pigtail hose MPT fitting connection(s) to regulator body
More informationTB132. Gas Conversion Kits for NV & NVS Heaters. Issue 1.0 May Applies to models: NV & NVS
TB132 Issue 1.0 May 2018 Applies to models: NV & NVS Gas Conversion Kits for NV & NVS Heaters www.powmatic.co.uk +44 (0) 1460 53535 info@powrmatic.co.uk General Information Heater conversion between gases
More informationG196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve
Installation Instructions Issue Date August 19, 2008 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied
More informationOPERATING INSTRUCTIONS AND PARTS LIST FOR ELECTRIC VAPOURISERS TYPES ADCENG 200E/250E
OPERATING INSTRUCTIONS AND PARTS LIST FOR ELECTRIC VAPOURISERS TYPES ADCENG 200E/250E P O BOX 5413, JOHANNESBURG 2000 TEL: (011) 493-8209 FAX: (011) 493-1459 E.MAIL : info@adceng.co.za P O BOX 37208, CHEMPET
More informationG196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve
Installation Instructions Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied
More informationSummary of the MRA LPG Codes of Practice
Summary of the MRA LPG Codes of Practice COP A1 DESIGN and INSTALLATION Code COP A1 deals with above ground installations where LPG is stored under pressure at ambient temperatures in fixed vessels larger
More informationWhat is LPG? Released Energy in the narrowest area. Clean and sure in the practise
since 1975 The company FAS (Flüssiggas-Anlagen GmbH, Salzgitter) was established in 1975 as commercial enterprise for LPG equipment (propane/butane). At the end of the seventies the safety idea gained
More informationOverview EUSSAM12. Carry out tightness testing and direct purging of gas installations
Overview This standard covers tightness testing and direct purging of low or medium pressure gas, in accordance with approved procedures and practices. It covers the standards required to meet the requirements
More informationACS.CoNGLP1 SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC NATURAL GAS TO LPG GENERIC
ACS.CoNGLP1 SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC NATURAL GAS TO LPG GENERIC Issue 4.2 ACS. SMB 1 CoNGLP1 INITIAL & RE-ASSESSMENT Range All LPG fittings. Comprises: 2. Gas emergency
More informationPerformance Literature for J48. Gas Pressure Regulators 2½ 6 Sizes. Catalogue
Catalogue and Performance Literature for J48 Gas Pressure Regulators 2½ 6 Sizes Catalogue General Information CS4807C Regulating Capacity Flow Capacity Figures 2½ & 3 DS4819A Flow Capacity Figures 4 &
More informationNorth American Orifice Metering System
Combustion North American Orifice Metering System 8697 and M8697 Metering Orifices accurately measure gas flows to industrial burners. They are compact, inexpensive, and can be installed in individual
More informationUsing propane cylinders safely
Using propane cylinders safely This leaflet is for the safe use of Calor Gas propane cylinders. If you have any queries please contact your local retailer. Calor supplies Liquefied Petroleum Gas (LPG)
More informationLNVx Gas Conversion Kit Instructions
TB134 Issue 1.0 Nov 2018 Applies to models: LNVx LNVx Gas Conversion Kit Instructions +44 (0) 1460 53535 info@powrmatic.co.uk www.powrmatic.co.uk General Information Heater conversion between gases will
More informationGas Conversion Kits CERAMIC HEATER SERIES (1, 2, 3, 4 Burner Units)
DESCRIPTION These kits are designed to convert from one gas type to another (eg. from NATURAL to PROPANE or from PROPANE to NATURAL) only for new heaters (5 years or newer) by replacing the gas valve spring
More informationG96 Series BASOTROL Dual Operator Valve
Installation Instructions 9. Issue Date February 22, 2013 G96 Series BASOTROL Dual Operator Valve Applications The G96 valves are combination, dual operator, automatic valves available with or without
More informationFirst Stage Regulators
DOMESTIC First stage regulators are typically used to reduce tank pressure to an intermediate pressure, usually 5 to 10 PSI for further pressure reduction by a second stage regulator located closer to
More informationDouble Stage Low Pressure Regulator JUMBO KOSAN Type 584
JUMBO KOSAN Type 584 The Type 584 is a double-stage low-pressure regulator, with inlet connection for automatic valves 35 mm in diameter. The Type 584 is a double-stage regulator constructed to control
More informationGrundfos GT TANK Keep it safe
GRUNDFOS GT TANK Grundfos GT TANK Keep it safe Long-life tanks for all needs Grundfos pressure tanks are all ideally suited and approved for use with drinking water. The material used ensures that there
More informationOperational Settings:
instrucalc features more than 70 routines associated with control valves, ISO flow elements, relief valves and rupture disks, and calculates process data at flow conditions for a comprehensive range of
More informationPressure ranges and accuracy classes for outlet pressure and safety devices
M2R Two Stage Regulator Applications Pressure reduction for: - Domestic use - Small industrial applications Brief information The two stage pressure regulator M2R is available in various capacity stages,
More informationRESIDENTIAL REGULATORS
RESIDENTIAL REGULATORS Type B NG Process Management TM B NG Regulators Description! BODY RESISTANT TO HIGHER PRESSURES Various Springs Adaptable to various fluids (Natural Gas, LPG, Manufactured Gas, etc.)!
More informationYour local gas generation partner. Precision series Modular gas generation solution for GC.
Your local gas generation partner Precision series Modular gas generation solution for GC www.peakscientific.com Perform with Precision Specifically designed and engineered for GC laboratory applications,
More informationValve Proving System VDK 200 A S02
Valve Proving System VDK 200 A S02 Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter
More informationValve Proving System VDK 200 A S06*
Valve Proving System VDK 200 A S06* Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter
More informationBottled Gas. Using LPG safely. for the way you want to live
Bottled Gas www.jsygas.com Using LPG safely for the way you want to live Using LPG safely An introduction This guidance is aimed at small-scale users of LPG in cylinders. It does not apply to LPG from
More informationCPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL
CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL Company Registered Office: Crown House, Stockport, Cheshire, SK13RB No. 850 0700 67 Registered in England and Wales No. 05058855
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS HIGH ALTITUDE APPLICATION CONVERSION INSTRUCTION HIGH EFFICIENCY GAS FURNACES 1PS0306 / 1PS0307 / 1PS0308 / 1PS0309 / 1PS0901 / 1PS0902 / 1PS0903 FOR USE WITH MODELS:
More informationISO INTERNATIONAL STANDARD. Gas cylinders Specifications and testing of LPG cylinder valves Self-closing
INTERNATIONAL STANDARD ISO 14245 First edition 2006-02-15 Gas cylinders Specifications and testing of LPG cylinder valves Self-closing Bouteilles à gaz Spécifications et essais pour valves de bouteilles
More informationCFD Modelling of LPG dispersion
CHAM Limited Pioneering CFD Software for Education & Industry CFD Modelling of LPG dispersion Demonstration example The following describes the numerical analysis of the dispersion of gas release from
More informationImportant for you: Please fill in and send back your GUARANTEE CARD straight away!!
ROHDE RAKU TOPLOADING KILNS up to 1150 C Our ROHDE RAKU Toploading Kilns are the result of intense further development of smaller and medium-sized ceramic kilns. The result is a 1150 C kiln with reduction-resistant
More informationArt PRESSURE REDUCER
FUNCTION ICMA pressure reducers are devices that reduce and stabilize the incoming pressure from the water supply. Pressure reducers allow correct use on domestic systems, reducing malfunctions due to
More informationPropane Conversion Kit Instruction
Propane Conversion Kit Instruction Condensing gas boiler Required Input Rates Logamax plus GB62-80 kw 270,000 btu/hr Logamax plus GB62-00 kw 35,000 btu/hr This kit and instructions are for converting the
More informationInstallation and maintenance of twin 45kg LPG cylinder systems
LPG Association Code of Practice LPGA COP No 2 Installation and maintenance of twin 45kg LPG cylinder systems July 2014 LPG Association of New Zealand Inc PO Box 1776 Wellington New Zealand 2 Foreword
More informationSerie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection
Flanged back flow preventer with controllable reduced pressure zone made in Application fields WATER FIRE FIGHTING DRINKING WATER 64 www.brandoni.it The ECO 3F flanged backflow preventers, which have a
More informationPressure Regulators. Operating Instructions. Instrumentation
Pressure Regulators Operating Instructions FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THIS PRODUCT CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from the
More informationBGA158 Series CE Approved Class A Shutoff Gas Valve
Installation Instructions BGA158 Issue Date August 24, 2011 BGA158 Series CE Approved Class A Shutoff Gas Valve Applications The BGA158 Series shutoff gas valve is an electrically operated gas valve that
More informationLiquefied Petroleum Gas Market Regulations S.L
Liquefied Petroleum Gas Market Regulations S.L. 423.31 INSPECTION & RISK ASSESSMENT REPORT ON LPG SECONDARY STORAGE INSTALLATIONS i Fill-In Instructions: (i) This LPG Secondary Storage Inspection report
More informationBRIEF IDEA ON LPG SAVINGS IN DOMESTIC CYLINDERS, TO BE ACHIEVED NOW:-
GOVT CAN SAVE RS.5000 CRORES ANNUALLY BY LPG SAVINGS IN DOMESTIC CYLINDER GOVT CAN PROMOTE DOMESTIC LPG 25 % BY RETROFITTING ON CYLINDER AT RS.500/- BRIEF IDEA ON LPG SAVINGS IN DOMESTIC CYLINDERS, TO
More informationThis system is installed throughout Japan, where our market share is more than 90%. Note
Events such as massive earthquakes can cause gas pipes and tanks to break and the leaking gas can cause fires and explosions. The sensor and the shut-off valve are installed with the LP-gas cylinders to
More informationSV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series
SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT SV/614 Series SV-DLE/614 Series Normally closed automatic shutoff valve with proof of closure and the following approvals. CSA Certified
More informationDANGER WARNING IMPORTANT
BWC Series Instructions for Field Conversion From: Natural Gas to LP LP to Natural Gas D E S I G N E D T O L E A D DANGER These instructions include a procedure for adjusting the air-fuel mixture on this
More informationSAFETY POLICY AND PROCEDURE MANUAL All Euramax Subsidiaries. Number K-3.0 Welding Safety Procedures
Number K-3.0 Issued: 1/2009 Revised: 3/2016 Page 1 of 3 1.0 PURPOSE: To standardize procedures associated with production and maintenance welding and to minimize the potential risk of accident or injury
More informationWelcome to Flogas. Metered Estates. You would never know you were off the grid. Metered Estates Welcome Pack.indd 1 18/01/ :48
Welcome to Flogas Metered Estates You would never know you were off the grid. Metered Estates Welcome Pack.indd 1 18/01/2016 16:48 Welcome to Flogas Metered Estates Why Flogas is the right choice A leading
More informationFlanged pressure reducer/stabilizer VRCD
Flanged pressure reducer/stabilizer VRCD 2 This unit reduces and stabilizes the upstream pressure by operating on its load losses with a constant downstream pressure irrespective of the rate of flow value.
More informationPRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL
PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL Company Registered Office: Crown House, Stockport, Cheshire, SK13RB No. 850 0700 67 Registered in England and Wales No. 05058855
More informationTEST SPECIFICATION NYT-909-C
748 Starbuck Ave, Watertown, NY 13601 Phone: +1-315-786-5200 Engineering Fax: +1-315-786-5673 TEST SPECIFICATION NYT-909-C CODE OF TESTS FOR TESTING "AB" TEST RACK P/N 702546 & 702612 ISSUE NO. 5 1.0 THE
More informationUSE A RELIABLE A INNOVATIVE A COST EFFICIENT GAS EQUIPMENTS AND GAS SYSTEMS
USE A RELIABLE A INNOVATIVE A COST EFFICIENT GAS EQUIPMENTS AND GAS SYSTEMS Air & Opp. Pudumjee Paper Mills, Thergaon, Chinchwad, Pune, Maharashtra State, India-411033 Telephone. ++91 20 27273809 Telefax
More informationSCIENCE LAB UTILITY CONTROLS
SCIENCE LAB UTILITY CONTROLS INCORPORATING GAS PRESSURE PROVING GAS PRESSURE PROVING EQUIPMENT - ENGINEERED TO DELIVER EXCEPTIONAL LEVELS OF SAFETY THE MERLIN RANGE DESIGNED FOR EDUCATIONAL LABORATORIES
More informationUSE AND ASSEMBLY INSTRUCTIONS
USE AND ASSEMBLY INSTRUCTIONS Model: HSQ-A213S; HSQ-B213S; HSQ-A214S; HSQ-B214S; HSQ-A215S; HSQ-B215S; HSQ-A216S; HSQ-B216S HSQ-A213S HSQ-A214S HSQ-A215S HSQ-A216S FOR OUTDOOR USE ONLY PLEASE READ INSTRUCTIONS
More informationThe conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.
ACCESSORY KIT INSTALLATION INSTRUCTIONS HIGH ALTITUDE APPLICATION CONVERSION MID-EFFICIENCY SINGLE-STAGE INDUCED COMBUSTION FURNACES MODELS: P*HU/G8T-UH/L8T-UH/FL8 UPFLOW / HORIZONTAL P*DN/G8T-DN/L8T-DN
More informationMedical Oxygen Concentrator Systems. Generate gases on site generate savings
Medical Oxygen Concentrator Systems Medical Oxygen is a critical and important commodity to all Heath Care Facilities (HCF s) How is Oxygen Supplied? The supply of Oxygen to the HCF can typically be done
More informationPropane Conversion Kit Instruction
Propane Conversion Kit Instruction Condensing gas boiler Required Input Rates GB142-24 84,800 btu/hr GB142-30 106,000 btu/hr GB142-45 160,900 btu/hr GB142-60 214,800 btu/hr This kit and instructions are
More informationCopyright, 2005 GPM Hydraulic Consulting, Inc.
Troubleshooting and Preventive Maintenance of Hydraulic Systems Learning to Read the Signs of Future System Failures Instructed by: Al Smiley & Alan Dellinger Copyright, 2005 GPM Hydraulic Consulting,
More informationInstallation Instructions For Natural Gas Conversion
Installation Instructions For Natural Gas Conversion (Kit Part No. 1175405) This kit is designed to convert PGX4 and PX4 Two -Stage Gas units for use with Natural Gas. Table 1 Heating Value at Altitude
More informationSerie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E
Serie ECO T Threaded end back flow preventer with controllable reduced pressure zone BRANDONI made in E U R O P E Application fields WATER FIRE FIGHTING DRINKING WATER 74 www.brandoni.it Serie ECO T The
More informationAutomatic Changeover Regulator with Over Pressure Shut Off (OPSO)
For Gas Supplier and Gas Equipment Installers Automatic Changeover Regulator with Over Pressure Shut Off (OPSO) This instruction manual describes the correct way of operating and handling regulators. It
More informationOPERATION AND MAINTENANCE MANUAL
OPERATION AND MAINTENANCE MANUAL Skum Bladder Tank Type Vertical. Table of Contents Page General Description 2 1. Installation 1.1 Safety 2 1.2 Transporting 2 1.3 Inspection 2 1.4 Filling Instruction 3-7
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0501 FOR USE WITH 95% MODELS: TG9S, GG9S (130,000 BTU ONLY) FOR USE WITH 80% MODELS: TG(8,L)S, GG(8,L)S (130,000
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS 1NP0680 - PROPANE CONVERSION FOR USE WITH MODELS: PM8, PC8, PM9, PC9, FL9M, FL9C, FC9M, FC9C This conversion kit is to be installed by a qualified service agency
More informationINSTALLATION INSTRUCTIONS for Filling and Transfer Kits including 2nd cylinder Connection Hose
GASLOW REFILLABLE CYLINDER SYSTEMS INSTALLATION INSTRUCTIONS for Filling and Transfer Kits including 2nd cylinder Connection Hose Filling Kits 01-4100 1.5m Kit - WHITE 01-4150 1.5m Kit - BLACK 01-4106
More informationAnnual Report on Liquefied Petroleum Gas (LPG) Related Accidents
Annual Report on Liquefied Petroleum Gas (LPG) Related Accidents (2016 version) The High Pressure Gas Safety Institute of Japan (KHK) 1. Introduction This Annual Report describes accidents that occurred
More informationHOT SHOT OPERATING INSTRUCTIONS AND OWNER S MANUAL. Model SPC-500. (Propane Torch)
OPERATING INSTRUCTIONS AND OWNER S MANUAL Model # SPC-500 READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who
More informationIncorrect installation, adjustment, or misuse of this burner could result severe personal injury, or substantial property damage.
Operating instructions GB VD Burners Incorrect installation, adjustment, or misuse of this burner could result severe personal injury, or substantial property damage. To the Equipment Owner: Please read
More informationINNOVATIVE & COMPLETE GAS SUPPLY SYSTEM FOR MEDICAL AND HOSPITAL APPLICATIONS
INNOVATIVE & COMPLETE GAS SUPPLY SYSTEM FOR MEDICAL AND HOSPITAL APPLICATIONS ALPI-LINE THE ADAPTED SOLUTION FOR MEDICAL GAS SUPPLY IN HOSPITALS Ceodeux Meditec is the medical range of the Rotarex Group
More informationCSO/STORMWATER MANAGEMENT. HYDROVEX FluidMoon Self-Adjusting Knife-Gate Regulator
CSO/STORMWATER MANAGEMENT HYDROVEX FluidMoon Self-Adjusting Knife-Gate Regulator HYDROVEX FLUIDMOON SELF-ADJUSTING KNIFE-GATE REGULATOR APPLICATION The Hydrovex FluidMoon Self-Adjusting Knife-Gate Regulator
More informationRegO Innovations - The Tradition Continues
See the Difference. RegO Innovations - The Tradition Continues From the company that pioneered propane regulators, you expect nothing less than products that lead the industry. For over 100 years, we have
More informationDraft. Not yet Approved
201178 Part 12.5.20 Recommended Safety Instructions for LP-Gas Winter Switch Protection Devices Revised 201178 (6 Pages) A. Purpose 1. This Manual Part recommends instructions for LP-Gas systems servicing
More informationDigester Processes. 1. Raw Sludge Pumping System
Digester Processes 1. Raw Sludge Pumping System Removes accumulated sludge from the primary clarifiers, pumped through 1 of 2 pipes either 150 or 200mm in diameter (Fig. 1.1). Fig 1.1 Pipes feeding Digesters
More informationDRAFT GUYANA STANDARD
2017-11-24 DRAFT GUYANA STANDARD Specification for Low Pressure Regulators for use with Liquefied Petroleum Gas (LPG) COMMENTS PERIOD: December 04, 2017- February 04, 2018 Guyana National Bureau of Standards
More informationWelcome to your new Firepod It will only work properly on Propane Gas (Also known as LPG and Patio Gas) with the special regulator supplied
Welcome to your new Firepod It will only work properly on Propane Gas (Also known as LPG and Patio Gas) with the special regulator supplied To enjoy your Firepod safely please read the instructions and
More informationSafety. Operating instructions Filter module VMF Measuring orifice VMO Fine-adjusting valve VMV DANGER. Contents WARNING CAUTION
..0. 0 Edition. D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Filter module VMF Measuring orifice VMO Fine-adjusting valve Translation from the German 00 00 Elster GmbH
More informationACS.CoNGLP1 SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC NATURAL GAS TO LPG GENERIC
ACS.CoNGLP1 SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC NATURAL GAS TO LPG GENERIC Issue 8.1 ACS. SMB April 2018 1 CoNGLP1 INITIAL & RE-ASSESSMENT Range All LPG fittings. Comprises: 2.
More informationTypes 749B and R130 Changeover Manifolds
Instruction Manual MCK-1179 Types 749B and R130 June 2012 Types 749B and R130 Changeover Manifolds TYPE HSRL-749B TYPE 64SR/122 TYPE R130/21 TYPE 749B/21 Figure 1. Changeover Manifolds and Regulator Assemblies
More informationUser Information Sheet 013
User Information Sheet 013 Formerly LPGA Technical Memorandum NO.81 Issue 2 September 2007 ACME threaded couplings 1 INTRODUCTION ACME threaded couplings/end fittings are widely used for LPG transfer operations
More informationFor use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY
For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum : FOR OUTDOOR USE ONLY Small Tank LP Kit (STLPK) Installation & Operation Instructions Installation We suggest
More informationCable Pressurization Buffering
Cable Pressurization Buffering What This Practice Is About Introduction This practice describes the various buffering practices that are used to protect the integrity of the pressurized cable network during
More information36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS
INLET PRESS TAP WTE-RODGERS 36E54-214 DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
More informationA rising main is a system of pipe work and valves that enables water to be delivered for fire fighting purposes to all floors in buildings over 18
Rising mains A rising main is a system of pipe work and valves that enables water to be delivered for fire fighting purposes to all floors in buildings over 18 metres high. It consists of a vertical pipe
More informationTHE INFLOW OF UNWANTED AIR
IN PRESSURIZED PIPES The main reason for the inflow of air in public water distribution systems is excessive water velocity. Air traveling with water in pressurized pipes can result in high turbulence
More informationfor Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity)
for Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity This is a Pilot operated pressure reducing valve. It is suitable to install in the steam lines with the
More informationDSEAR- Storage, Use and handling of gas cylinders guidance.
OHSS: Storage, Use and handling of gas cylinders guidance 202 DSEAR- Storage, Use and handling of gas cylinders guidance. Contents Introduction... 2 General recommendations for storage, use and handling....
More informationBGA158 Series CE Approved Class B Shutoff Gas Valve
Installation Instructions BGA158 Issue Date March 22, 2016 BGA158 Series CE Approved Class B Shutoff Gas Valve Applications The BGA158 Series shutoff gas valve is an electrically operated shutoff valve
More informationAuxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998
Auxiliary valve Sequence valve, 3-way Catalogue 9129 8542-02 (GB) 9129 8542-06 (US) October 1998 Sequence valve, 3-way Applications The sequence valve is designed to open or close a hydraulic pilot signal
More informationTHE FOLLOWING MATERIALS ARE FOUND IN THIS PACKET:
Date: Dear Customer: The following letter and enclosed information is VERY IMPORTANT. Please take the time to read ALL of the information presented. ***This form must be signed and returned as soon as
More informationInstallation and operation manual SUNWOOD MARINO LPG
Installation and operation manual SUNWOOD MARINO Version: Natural Gas LPG Specifications Manufacturer Sunderman Openhaarden V.O.F. / Sunwood Contact details Christiaan Huygensstraat 10 2665 KX Bleiswijk
More informationKOMPRESSOREN COMPRESSORS KAESER AIR SERVICE Our Services An Overview
KOMPRESSOREN Our Services An Overview Fully equipped 100% quality and service One of the key requirements for any compressed air application is maximum compressed air availability. This is achieved however
More informationSL G3. Warning
Important: If converting from Propane to Natural Gas - order the Natural Gas Conversion Parts Kit (IBC Part # P-307) from your authorized IBC Distributor. Use the Propane Gas conversion parts kit if the
More informationMANUAL GAS MANIFOLDS
MANUAL GAS MANIFOLDS Phoenix Pipeline Products Limited. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com
More informationSeptember 2017 Safety Meeting Conducting Regulator Performance Tests
September 2017 Safety Meeting Conducting Regulator Performance Tests When a gas appliance is turned on, gas flows through the line to the appliance where it is burned. The regulator ensures that the proper
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 10464 First edition 2004-08-15 Gas cylinders Refillable welded steel cylinders for liquefied petroleum gas (LPG) Periodic inspection and testing Bouteilles à gaz Bouteilles rechargeables
More informationUser Information Sheet 028
User Information Sheet 028 Revised: January 2014 Scope This Information Sheet gives general guidance for all users in domestic, small commercial and industrial applications who use LPG (Liquefied Petroleum
More informationDual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series
Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series Two normally closed automatic shutoff valves in one housing. Valve 1 (V1) incorporates
More informationUNIVERSAL GAS FRYER Instruction Manual Model #8065NS
Part No. 88847 Revised: August 2004 UNIVERSAL GAS FRYER Instruction Manual Model #8065NS Cincinnati, OH 45241-4807 USA GAS SAFETY PRECAUTIONS OPERATING INSTRUCTIONS UNPACKING AND ASSEMBLY After unpacking
More informationUNLOADING PROCEDURE OF AN AIRFLOW CONTAINER
UNLOADING PROCEDURE OF AN AIRFLOW CONTAINER LCO2 / LN2O 1-07.05.13 PHASE 1 : Preliminary check and first manipulations before the discharge 1. Security rules 1. Wear all required safety equipments for
More information