Legionella Awareness
|
|
- Ezra Bruce
- 6 years ago
- Views:
Transcription
1 Presents Legionella Awareness Presented by Matt Round M.W.M.Soc, TechIOSH
2 HISTORICAL REVIEW The first outbreak occurred following a convention of American Legionnaires (hence the name), in the Bellevue-Stratford Hotel in Philadelphia, USA. 182 people confirmed infected 29 people died
3 HISTORICAL REVIEW Legionella Pneumophila was identified as the causative agent for the first time
4 HISTORICAL REVIEW The oldest known case of legionnaires disease, following retrospective analysis of isolates
5 HISTORICAL REVIEW The oldest isolated case identified in the UK from Nottingham
6 HISTORICAL REVIEW The first case identified as Legionnaires Disease in the UK was in Corby
7 HISTORICAL REVIEW First recognised UK hospital outbreak in Kingston
8 HISTORICAL REVIEW The WHO recommend screening for Legionella infection in all admitted cases of pneumonia
9 HISTORICAL REVIEW Major outbreak at Stafford Hospital 175 confirmed cases 28 deaths
10 HISTORICAL REVIEW Major outbreak at BBC Broadcasting House, increasing public awareness 70 confirmed cases 3 deaths
11 HISTORICAL REVIEW Copthorne Hotel, Cardiff 70 confirmed cases 3 deaths
12 HISTORICAL REVIEW Westfriese Flower Show Netherlands 242 confirmed cases 22 deaths
13 HISTORICAL REVIEW Murcia in Spain 449 confirmed cases 6 deaths
14 HISTORICAL REVIEW Barrow in Furness 131 confirmed cases 7 deaths Design Services Manager charged with negligence
15 HISTORICAL REVIEW Merthyr Tydfil, Wales 22 confirmed cases 2 deaths
16 HISTORICAL REVIEW Playboy Mansion 200 confirmed cases 0 deaths
17 HISTORICAL REVIEW Edinburgh 50 confirmed cases 3 deaths Stoke-on-Trent 19 confirmed cases 1 death
18 LEGIONNAIRES OCCURRENCE Legionella bacteria are common and can be found naturally in environmental water sources Typically 200 to 250 cases reported annually (underestimated!) Around 50% of cases associated with travel abroad Cases of Legionnaires disease have occurred among staff in the workplace (factories, offices, shops and hospitals); visitors (delivery drivers) and members of the public (patients, hotel guests or passers-by) people die annually due to Legionnaires Disease However, there are approximately 180,000 pneumonia cases each year in the UK
19 TRANSMISSION The primary route of infection is the inhalation of aerosols contaminated with legionella bacteria. So for legionnaires disease to develop, the bacteria needs to get into the lungs. Anything that may aid in that process (eg. smoking) will increase that persons susceptibility to legionnaires disease. Legionnaires disease cannot be contracted from another person infected with the disease. A second method has been described recently called "Aspiration. Aspiration is the inhalation of secretions in the mouth into the lung instead of to the stomach which is normally due to decreased or absent gag reflex.
20 SUSCEPTIBILITY Patients with increased susceptibility Diabetes Respiratory Disease Cancer Kidney Disease Immunosuppressant Drugs (steroids etc) Alcoholism Patients with very high susceptibility Head/Neck Cancer Bone Marrow Transplant Renal Dialysis Leukaemia Organ Transplant AIDS Smokers Over 45s
21 WHAT LEGIONELLA NEEDS Before legionella becomes a problem, it needs some of the following to help it proliferate and to spread; Stagnation Nutrients Temperature between o C Oxygen Protective Environments Aerosolisation The 6 faces of the cube When looking at any water system, look at it for the potential for any of the above to occur.
22 CONFIRMED SOURCES Domestic Water Systems Cooling towers Spa Baths Humidifiers Dental Chairs Drilling/grinding machines Misting machines Ornamental fountains
23 EFFECT OF FAILIURE
24 UK LAW AND WHERE L8 FITS IN LAW MUST DO EVIDENCE BASED BEST PRACTICE INFO GUIDANCE
25 UK LAW AND WHERE L8 FITS IN There are 4 main statutes which are relevant to the control of legionella bacteria; All of the above have been considered by the Health and Safety Commission when writing the Approved Code of Practice L8, along with what practices have proven efficacy (i.e. best practice). The L8 is not however legislation. If you were to be prosecuted, it would probably be under HSWA as it is this which gives the ACoP L8 it s bite.
26 UK LAW AND WHERE L8 FITS IN 2013 ACoP L8 (revised)..and supporting guidance HSG274 in early 2014
27 LEGALLY WHAT YOU MUST DO Identify & Assess Risks Write a Scheme of Precautions Keep a Record Implement Precautions
28 RESPONSIBILITY AND COMMUNICATION Key Responsibilities Statutory Duty Holder Responsible Person Nominated Deputy Competent Help Person in control of the premises and water systems. Typically a Chief Executive, Managing Director or General Manager. They have ultimate responsibility for health and safety matters. Manager, Director or someone who has similar status and sufficient authority, competence and knowledge who has been delegated managerial responsibility for the control of legionella Someone of sufficient competence and knowledge so that someone can always be contacted The Legionella Control Association is a voluntary organisation and consists of both product suppliers and independent consultants. Potential conflict of interest should be considered when choosing a contractor. It is essential that there are clearly defined responsibilities in writing which are understood by all those involved.
29 RISK MANAGEMENT A foreseeable risk of exposure to Legionella Bacteria therefore exists in: cooling towers evaporative condensers hot and cold water systems humidifiers, air washers, softeners, emergency showers, sprinklers / hose reels, lathe coolants, spas, horticultural misting, dentistry, car washes & indoor water features any other water system where the water temperature may exceed 20 C and a spray or aerosol be released during operation or maintenance.
30 RECORD KEEPING Schematics
31 Design & Construction COLD WATER SYSTEMS Cold water storage systems should be designed to avoid the conditions favouring growth of Legionella and to allow easy cleaning and disinfection and inspection. Tanks should comply with the Water Supply (Water Fittings) Regulations 1999 (old byelaw 30) and should therefore have; Storage capacity of less than 24 hours A tight fitting lid with inspection hatch allowing inspection without damaging the insulation Insect screens fitted to the vent, overflow and warning pipe preventing foreign objects and debris entering the system. Important note : A great way to eliminate the risks presented by cold water storage in open tanks and large volumes, is by moving to mains pressure systems, with Reduced Pressure Zone (RPZ) valves replacing tanks. The inlet opposite the outlet, ensuring a good flow of water through the tank preventing stagnation hotspots. Insulation all over to prevent greater than 2 C heat gain A good working drain fitted
32 COLD WATER SYSTEMS Operation & Monitoring Cold water should be below 20 o C at all times The incoming cold water inlet temperature should be measured at least once in the winter and once in the summer. Cold water storage tanks should be visually inspected annually and should be cleaned and disinfected if necessary and any faults rectified. See slide on cleaning & disinfection later Record the total water consumption over a typical day and whenever the building use changes, this should be repeated. Check nearest and furthest cold water outlet temperatures are below 20 o C within 2 mins. flow on a monthly basis. A representative number of cold water outlets should also be tested on a rotational basis once a year. Install high use outlets upstream of lower use outlets to maintain flow. Review cold water circuit plans annually and remove redundant outlets
33 Operation & Monitoring HOT WATER SYSTEMS Calorifiers on standby use or out of service for >7 days should be thermally disinfected at 60 o C for on hour AVOID TEMPERATURES BETWEEN 20 o C AND 50 o C Store hot water >60 o C and distribute >50 o C Where scalding is a risk, use thermostatic mixing valves Remove dead-legs and cut back redundant outlets Infrequently used outlets and particularly showers, should be flushed weekly for several minutes to prevent stagnation Calorifiers should be drained and inspected annually. The system should then be cleaned and disinfected Flow and return temperatures should be logged monthly. Building Management Systems (B.M.S.) may be used to automate this task Check that the nearest and furthest hot water outlet temperatures are above 50 o C within 1 min flow on a monthly basis and a representative number of other outlets once a year
34 If it s not logged, it s not done! RECORD KEEPING Record systems should include the following information: Details of the risk assessment this must be current, including schematics and clearly defined lines of communication Details of precautionary measures implemented this is the information detailed in the written scheme Monitoring, inspection, test and check results a record of all results including signatures, dates and what was actioned when out of specification a record of analyses (as appropriate) an asset inspection record, including subsequent remedial actions a record of cleaning and disinfection, including details of chlorination levels, temperatures (during pasteurisation) and certification personnel training records - including this course! Risk assessments & control schemes should be kept whilst current & for 2 years after that period. Monitoring results should be retained for 5 years.
35 COOLING PROCESS Types of Cooling Tower Forced Draught Moist Air Moist Air drift eliminators reduce the aerosol spray released to atmosphere The hot water falls through the packing & cools in the air stream distribution system ensures even flow of water over the tower AIR IS FORCED THROUGH THE TOWER BY THE FAN After cascading through the packing the water is collected in a sump or pit
36 COOLING PROCESS Types of Cooling Tower Induced Draught Moist Air THE FAN SUCKS AIR THROUGH THE TOWER The hot water falls through the packing & cools in the air stream The hot water falls through the packing & cools in the air stream
37 Types of Cooling Tower Evaporative Condensers COOLING PROCESS Medium to be cooled The volume of cooling water in this type of system is very small as it is only in the sump and pipework. Air in Evaporative condensers do not have any packing inside them. Instead they have tubes which carry a secondary medium which requires cooling.
38 If in doubt The HSE Approved Code of Practice L8 and HSG274 provides detailed guidance on the operation and management of wet cooling systems and hot and cold water systems - please consult this document for further guidance. IF IN DOUBT - SEEK EXPERT ADVICE
LEGIONELLA MANAGEMENT PROCEDURE
LEGIONELLA MANAGEMENT PROCEDURE This procedure sets out the aims and objectives of the school and outlines responsibilities for managing the risk of exposure to legionella. General Statement of Intent
More informationIntroduction. Legal Duties. Risk Assessment
All Hampstead Hill School Policies are always to be read and considered in conjunction with Equal Opportunities, Race Equality and Inclusion Policies. This Policy of Hampstead Hill School applies to all
More informationLegionella Guidance. Property managers specialising in residential, apartment, block and estate management
Legionella Guidance Legionnaires disease is a potentially fatal lung infection - pneumonia, that is caused by the legionella bacteria. It can be caught by breathing in small droplets of contaminated water.
More informationInfection is caused by breathing in small droplets of water contaminated by the bacteria. The disease cannot be passed from one person to another.
DCH05 - Legionella Policy and Procedure Page: 1 of 6 Purpose Scope Policy Protect staff and patients from the risks from legionella. Service Provider and Registered Manager. What is Legionnaires disease?
More informationIHEA HFMC Stuart Lloyd. Managing Legionella: Achieving Best Practice. Legionella background
Stuart Lloyd worked in the industry since 1986 worked for 7 years with the water treatment arm of a Maintenance Contractor undertaking Legionella Risk Assessments including costing of any associated remedial
More informationThe Control of Legionella Bacteria in Water Systems. The Approved Code of Practice & Guidance L8.
The Control of Legionella Bacteria in Water Systems The Approved Code of Practice & Guidance L8. Contents 1. Background to Legionnaires Disease & Risk Systems 2. Requirements of The Approved Code of Practice
More informationLegionella Policy. Policy Ref: PS08. Prepared By. Georgina Kent, Operations Director. Date of Current Review August 2018
Legionella Policy Policy Ref: PS08 Prepared By Georgina Kent, Operations Director Date of Current Review August 2018 Date of Next Review August 2021 Reviewed By PHA Board 1. Introduction 1.1 The aim of
More informationControl of Legionella
OHSS Control of Legionella Guidance 103.1 Control of Legionella This guidance supports the Control of Legionella Health and Safety Management Standard. Contents 1 Introduction 2 2 Responsible and Appointed
More informationLegionella Management Policy
December 2017 Contents 1. Introduction 1 2. Policy Statement 1 3. Purpose and Scope 1 4. Management and Responsibilities 2 4.1 Duty Holder 2 4.2 Responsible Person 2 4.3 Jointly Accountable Responsible
More informationGUIDE TO LEGIONELLOSIS - Risk Assessment
Application Guide AG 20/2000 GUIDE TO LEGIONELLOSIS - Risk Assessment R G Brown M A Roper Application Guide AG 20/2000 GUIDE TO LEGIONELLOSIS - Risk Assessment R G Brown M A Roper Old Bracknell Lane West,
More informationHealth & Safety Policy HSP 07 Legionella Management Version Status Date Title of Reviewer Purpose/Outcome
Health & Safety Policy HSP 07 Legionella Management Version Status Date Title of Reviewer Purpose/Outcome 1.0 Draft 07.03.2016 David Maine 1 st Draft for consultation/review 1.1 Approved 22.12.2016 David
More informationLegionnaires disease
Legionnaires disease A guide for employers Health and Safety What is this leaflet about? Legionnaires disease A guide for employers This short and simple guide is written to help you, as an employer, understand
More informationWATER SAFETY / LEGIONELLA POLICY (2018)
1.0 INTRODUCTION WATER SAFETY / LEGIONELLA POLICY (2018) In order to be fully compliant with the Control of Substances Hazardous to Health (COSHH) Regulations as they apply to legionella, the Association
More informationCooling Tower Legionella Risk Assessment Checklist
Cooling Tower Legionella Risk Assessment Checklist Introduction This cooling tower legionella risk assessment checklist template is designed to help the responsible person audit the arrangements in place
More informationLEGIONELLA CONTROL POLICY
LEGIONELLA CONTROL POLICY Originator: Policy and Strategy Team Approval date: August 2018 Review date: August 2019 1 Introduction 1.1 1.2 1.3 1.4 Pine Court Housing Association (PCHA) treats the health
More informationLegionnaires disease: Technical guidance Part 3: The control of legionella bacteria in other risk systems
Legionnaires disease: Technical guidance Part 3: The control of legionella bacteria in other risk systems This guidance for dutyholders, including employers, those in control of premises and those with
More informationPrevention and Control of Legionella Policy
Prevention and Control of Legionella Policy Core Cover Page Prevention and Control of Legionella Policy Version number Dates produced and approved (include committee) Reason for production/ revision Author
More informationDomestic Hot & Cold Water Services Log Book
Domestic Hot & Cold Water Services Log Book Please ensure that a copy of the current building s Risk Assessment along with the Schematic is kept with this log book. This log book is NOT issued as part
More informationWATER MANAGEMENT & CONTROL OF LEGIONELLA POLICY Policy PROV 53 July 2010
WATER MANAGEMENT & CONTROL OF LEGIONELLA POLICY Policy PROV 53 July 2010 Document Management Title of document Water Management and Control of Legionella Policy Type of document Policy PROV 53 Description
More informationCODE OF PRACTICE AND GUIDELINES RELATING TO PREVENTION OR CONTROL OF LEGIONELLOSIS INCLUDING LEGIONNAIRES DISEASE
CODE OF PRACTICE AND GUIDELINES RELATING TO PREVENTION OR CONTROL OF LEGIONELLOSIS INCLUDING LEGIONNAIRES DISEASE THIS CODE OF PRACTICE AND GUIDELINES MUST BE READ IN CONJUNCTION WITH THE APPROVED CODE
More informationLegionnaires disease The control of legionella bacteria in water systems
The control of legionella bacteria in water systems Approved Code of Practice and guidance on regulations This book is aimed at dutyholders, including employers, those in control of premises and those
More informationHot tubs for Business why you need the PWTAG publication. Janice Calvert MSc,CChem,FRSC,FRSPH,FPWTAG Chair PWTAG
Hot tubs for Business why you need the PWTAG publication Janice Calvert MSc,CChem,FRSC,FRSPH,FPWTAG Chair PWTAG This book includes more practical guidance than HSG282 on how to assess and control the risks
More informationWILTSHIRE POLICE FORCE PROCEDURE. Control of Bacteria in Water Systems
WILTSHIRE POLICE FORCE PROCEDURE Control of Bacteria in Water Systems Date of Publication: June 2017 Version: 10.0 Next Review Date: June 2018 TABLE OF CONTENTS PROCEDURE... 3 PROCEDURE OVERVIEW... 3 GLOSSARY
More informationPolicy No: 45. Legionella Emergency Action Plan
Policy No: 45. Legionella Emergency Action Plan Coordinator Review Frequency Executive Operations Manager Annually Policy First Issued 2014 Last Reviewed Autumn Term 2017 Date policy considered by External
More informationPolicy and Guidelines for the Management and Control of Legionella
Policy and Guidelines for the Management and Control of Legionella 2017-20 1 P olicy for the Management and Control of Legionella 2017-2020 1. Introduction and Policy Statement This Policy and Guidelines
More informationTHE CONTROL OF LEGIONELLA BACTERIA IN WATER SYSTEMS
Safety Code of Practice 03 THE CONTROL OF LEGIONELLA BACTERIA IN WATER SYSTEMS Author: Andy Lucas / Mark Evans Issue Date: November 2017 Review Date: November 2018 Version Control Version Author/Changes
More informationLEGIONELLA POLICY OUR LADY & ST JOSEPH CATHOLIC PRIMARY SCHOOL
LEGIONELLA POLICY OUR LADY & ST JOSEPH CATHOLIC PRIMARY SCHOOL PREPARED BY: APPROVED BY: DATE: REVIEW DATE: This policy sets out the control of legionella in hot and cold water systems in school, including
More informationadministered by RC63: Recommendations for minimising the impact of legionella in firefighting systems
administered by RC63: Recommendations for minimising the impact of legionella in firefighting systems Version 1 Published 2015 IMPORTANT NOTICE This document has been developed through RISCAuthority and
More informationCONTROL OF LEGIONELLA POLICY
CONTROL OF LEGIONELLA POLICY DATE OF REVIEW: April 2017 DATE OF NEXT REVIEW: Summer 2020 TO BE REVIEWED BY: Finance Personnel and Premises The school also refers to the guidance laid down in Devon County
More informationGuide to Legionellosis
A BSRIA Guide www.bsria.co.uk Guide to Legionellosis Operation and maintenance By Reginald Brown and Mark Roper AG 19/2000 All rights reserved. No part of this publication may be reproduced, stored in
More informationApproved By H&S Forum
Staffordshire County Council Reference Number HR124 Policy Title HR Policy Handbook Issue 3 Approved By H&S Forum Date September 2016 Review Date September 2017 Glascote Academy WATER SYSTEM SAFETY Control
More informationWater Hygiene Chlorination Water Treatment Legionella Control
www.whs-ltd.com Water Hygiene Chlorination Water Treatment Legionella Control WATER STORAGE TANK DISINFECTION Cleaning and Chlorination Procedure A clean and chlorination has recently been carried out
More informationWarm Water Systems A Practical Guide. Based on over 24 years experience
Warm Water Systems A Practical Guide Based on over 24 years experience TMV Systems Circulate hot water Use TMVs at POU to lower temperature of water Centralised Systems Generate warm water in the plant
More informationTHE UNIVERSITY OF READING CONTROL OF LEGIONELLA BACTERIA WITHIN WATER SYSTEMS POLICY
Estates and Facilities THE UNIVERSITY OF READING CONTROL OF LEGIONELLA BACTERIA WITHIN WATER SYSTEMS POLICY Page 1 of 103 February 2016 review Legionella Control University of Reading This Document sets
More informationQualification Specification HABC Level 2 Award in Legionella Awareness (QCF)
www.highfieldabc.com Qualification Specification HABC Level 2 Award in Legionella Awareness (QCF) Qualification Number: 601/2972/4 Highfield House Heavens Walk Lakeside Doncaster South Yorkshire DN4 5HZ
More informationControl of Legionella Policy. July 2017 ORCHARD ACADEMY TRUST. Control of Legionella Policy -Page 1
Control of Legionella Policy July 2017 Control of Legionella Policy -Page 1 ORCHARD ACADEMY TRUST Control of Legionella Policy This policy sets out the control of legionella in hot and cold water systems
More informationEURO. ENVIRONMENTAL Compliance, Protection, Peace of Mind. Occupational Hygiene Safety Consultants
EURO ENVIRONMENTAL Compliance, Protection, Peace of Mind Occupational Hygiene Safety Consultants Water Hygiene (Legionella) Site Name: Site Address: Management Pathway Statutory duty holder Name PosiAon
More informationE PGN-11. Part of NTW (O)32 Estates Operations and Maintenance Policy Paul McCabe Head of Estates and Facilities-NTW Solution Ltd
Estates Operations and Maintenance Practice Guidance Note Management of Pressure Systems V01 Date Issued Planned Review PGN No: Issue 1 - Nov 2015 Issue 2 Nov 2017 Author / Designation Responsible Officer
More informationLEGIONELLA POLICY & MANAGEMENT PLAN UNIVERSITY OF ESSEX HUMAN RESOURCES / ESTATE MANAGEMENT SERVICE
LEGIONELLA POLICY & MANAGEMENT PLAN UNIVERSITY OF ESSEX HUMAN RESOURCES / ESTATE MANAGEMENT SERVICE VERSION 10.10.17. ISSUE1.2 (Updated 20.01.2018) 0 ISSUE 1 APPROVED BY USG 19.07.17 CONTENTS SECTION 1:
More informationSPATEX 2015 SPA OPERATOR SEMINAR
SPATEX 2015 SPA OPERATOR SEMINAR Water Treatment of Display Spas PRESENTER: Colin Jenkinson DATE: 3 rd February 2015 COLIN JENKINSON ISPE Endorsed Training Provider MIISRM Member of ISPE CMIOSH ACIEH &
More informationIssue date: April 2017
NSF Guide to commissioning, inservice testing and frequency of testing of Thermostatic Mixing Valves (TMV) for use in Healthcare premises as Type 3 valves (TMV3 approved). Issue date: April 2017 1. Introduction
More informationOperation and Maintenance manual Issue No: 1 Issue Date: 4th September 2007
Operation and Maintenance manual Document Title: Purewater CWST O&M Issue No: 1 Issue Date: 4th September 2007 This manual is to be used in conjunction with the following products manufactured by Purewater
More informationIssue date: July 2012 Issue 1
Guide to commissioning, in-service inspection, in-service test and frequency of testing Thermostatic Mixing Valves (TMV) for use in health and social care establishments as Type 3 valves (TMV3 approved).
More informationControl of Legionella and Pseudomonas Policy
Control of Legionella and Pseudomonas Policy Classification: Policy/Procedures Lead Author: Paul Chadwick Additional author(s): Dave Handley (Authorising Engineer Water), Sid Swindells Authors Division:
More informationScalding Now a Healthcare Worry Legionella Cases on the Rise Aging Population Safety Issues Hidden Costs of Status Quo ASSE 1016 Update
Scalding Risk Legionella Aging Population Hidden Costs Codes & Standards The Rising Need for Advanced Shower Valve Technology Scalding Now a Healthcare Worry Legionella Cases on the Rise Aging Population
More informationWater Safety Policy. Lead Manager. Corporate General Manager Facilities. & Infection Control Manager
Water Safety Policy Lead Manager Corporate General Manager Facilities & Infection Control Manager Responsible Director Approved By Director of Facilities Board Infection Control Committee & SCART Steering
More informationThe control of legionella and other infectious agents in spa-pool systems
The control of legionella and other infectious agents in spa-pool systems Spa-pool systems are a recognised source of diseases caused by infectious agents including the organism that causes legionnaires
More informationLegionella, Pseudomonas and general pathogen control in water systems
Legionella, Pseudomonas and general pathogen control in water systems Dr Tom Makin Makin & Makin Consultancy Ltd info@makinandmakin.co.uk Formerly, Directorate Manager Department of Medical Microbiology
More informationPressure Systems Safety Regulation
Pressure Systems Safety Regulation Introduction This document informs Faculty of the key requirements of the UK and Chinese Pressure Systems Safety regulations. The aim of these regulations is to prevent
More informationPRESSURE SYSTEMS POLICY
PRESSURE SYSTEMS POLICY PRESSURE SYSTEMS POLICY 1. Introduction 2. Policy Statement 3. Scope 4. Background 5. Roles & Responsibilities 6. Training 7. Contractors 8. Policy Review 1. Introduction The Kilmarnock
More informationInstallation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel
OM006 Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel The operating and maintenance instructions contained within this package are for standard mild steel buffer vessels
More informationGas Safety Management Policy
Date approved: 1 April 2014 Approved by: Audit and Risk Committee 1. Introduction 1.1 Every year people die and many others suffer ill-health from carbon monoxide poisoning caused by gas appliances and
More informationBCGA GUIDANCE NOTE 17
BCGA GUIDANCE NOTE 17 BCGA POLICY AND GUIDANCE FOR THE SAFE FILLING OF THIRD-PARTY OWNED AND / OR MAINTAINED TANKS Revision 2: 2013 BCGA GUIDANCE NOTE 17 BCGA POLICY AND GUIDANCE FOR THE SAFE FILLING OF
More informationQuest Operations 4 Health and Safety Declaration Guidance Notes Issue 10 - October 2016
Quest 2016 - Operations 4 Health and Safety Declaration Issue 10 - October 2016 Outcomes The signatory of the current health and safety policy will confirm that the facility being assessed meets: Health
More informationInstallation, Operation and Maintenance Instructions Buffer Vessel OM006
Installation, Operation and Maintenance Instructions Buffer Vessel OM006 Calorifiers Heat Exchangers Pressurisation Units Sales Tel: 01457 835700 Sales Fax: 01457 832700 E-mail: sales@gmsthermal.co.uk
More informationCall: Visit: LEGIONELLA (WATER HYGIENE) Control and Management. Training Prospectus Version 14
Call: 0333 121 1215 Visit: www.ppltraining.co.uk LEGIONELLA (WATER HYGIENE) Control and Management Training Prospectus Version 14 Legionella (Water Hygiene) Training Courses Introduction Introduction to
More informationConstruction Water Safety Plan
Construction Water Safety Plan Date Reason for update Date Approved Issued Construction WSP is a June 2013 further requirement the management of water systems TBC Update as a result of Dec2013 feedback
More informationWork Equipment: LOCAL EXHAUST VENTILATION
Health & Safety Services Safety Code of Practice 46: Part 4 2 nd Edition, September 2014 Work Equipment: LOCAL EXHAUST VENTILATION University of Reading 2015 Page 1 Contents 1 Scope... 3 2 Introduction...
More informationTMV3 Requirements IMPORTANT Installer:
TMV3 Requirements IMPORTANT Installer: This Manual is the property of the customer and must be retained with the product for maintenance and operational purposes. 1 1173533-W2-C General The information
More informationThe control of legionella and other infectious agents in spa-pool systems
Health and Safety Executive The control of legionella and other infectious agents in spa-pool systems The control of legionella and other infectious agents in spa-pool systems Health and Safety Executive
More informationSMV-001 Thermostatic Shower Mixer Valve Installation Instructions & Adjustment Settings
SMV-001 Thermostatic Shower Mixer Valve Installation Instructions & Adjustment Settings 38 READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. LEAVE THIS BOOKLET WITH THE END USER FOR FUTURE REFERENCE
More informationInstallation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve
Installation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve TMV3 / TMV2 Combined Valve C85079 C85081 C85080 C85082 It is important that these guidance notes are read and fully understood
More informationHealth and Safety Policy
Snowflake School Policy Reviewed September 2018 To be reviewed September 2019 Roy English Health and Safety Policy 1. STATEMENT OF INTENT The Trustees of Snowflake School will take steps to meet their
More informationHealth and Safety Executive and Local Authorities
Health and Safety Executive and Local Authorities Inspection topic pack to deliver Legionella Intervention Programme 2012 2014: Controlling the risks from Legionella in cooling towers and evaporative condensers
More informationINFORMATION NOTE No 353: MICROBIOLOGICAL TESTING
INFORMATION NOTE No 353: MICROBIOLOGICAL TESTING First issued: January 2007 Updated: June 2010 ABOUT ISRM This is one of a series of Information Notes produced by the Institute of Sport and Recreation
More informationInstallation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels
OM003 Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels The operating and maintenance instructions contained within this package are for standard storage vessels
More informationJuly 2017 Issue 12 Operations 4 Compliance Declaration Guidance Notes Page 1 of 10
Quest 2016 - Operations 4 Compliance Declaration Issue 12 - July 2017 Outcomes The signatory of the current health and safety policy will confirm that the facility being assessed meets: Health and Safety
More informationMAINTENANCE AND SAFETY OF CNG REFUELLING STATIONS
ISSN 1172-3416 NZ GCP 2 : 1993 NEW ZEALAND GAS CODE OF PRACTICE for MAINTENANCE AND SAFETY OF CNG REFUELLING STATIONS Issued by the Secretary of Commerce in accordance with the Gas Act 1992 THE GAS ACT
More informationEssential Chemical Safety & Hygiene Training 2015
Essential Chemical Safety & Hygiene Training 2015 Introduction What does this training cover? Knowledge of working with cleaning chemicals Forms part of induction training Forms part of on-going job training
More informationOverview EUSDSG3.12. Install gas meters and regulators (2.5 to 16.0m3/hr)
Overview This national occupational standard is for gas engineerswho are required to install and exchange meters and regulators (2.5 to 16.0m3/hr) on low pressure and medium pressure gas systems. This
More informationInstallation Instructions and User Guide
Installation Instructions and User Guide 15mm & 22mm In-Line Thermostatic Mixing Valve-TMV3 Model P402 It is important that these guidance notes are read and fully understood prior to product installation
More informationThe Management of Legionella in Air Washers, Wet Scrubbers, Particle and Trivial Gas Scrubbers
THE WATER MANAGEMENT SOCIETY The Management of Legionella in Air Washers, Wet Scrubbers, Particle and Trivial Gas Scrubbers Guidance produced by Water Management Society Working Party First published July
More informationSafe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant
Health and Safety Executive Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant Background Accidents involving
More informationCONTROL OF SUBSTANCES HAZARDOUS TO HEALTH PROCEDURE
CONTROL OF SUBSTANCES HAZARDOUS TO HEALTH PROCEDURE 1. INTRODUCTION The University uses substances hazardous to health in many of its operations, and accepts that it has a duty of care to reduce exposure
More informationSafety Management System. Initial Revision Date: Version Revision No. 02 GENERAL SAFETY HEALTH PROVISION
Revision Preparation: Safety Mgr Authority: President Issuing Dept: Safety Page: Page 1 of 5 Purpose This program is written to be in compliance with local regulatory requirements and provide directives
More informationInstallation Instructions and User Guide
Installation Instructions and User Guide 15mm & 22mm In-Line Thermostatic Mixing Valve-TMV2 Model P404 It is important that these guidance notes are read and fully understood prior to product installation
More informationPOLICY FOR THE CONTROL OF SUBSTANCES HAZARDOUS TO HEALTH (COSHH)
POLICY FOR THE CONTROL OF SUBSTANCES HAZARDOUS TO HEALTH (COSHH) INTRODUCTION & LEGISLATION Using chemicals or other hazardous substances at work can put people s health at risk. The law requires employers
More informationDeluge Optimo Shower valve and kit 10032CP
Deluge Optimo Shower valve and kit 10032CP Installation, Operation and Maintenance Please leave these instructions with the user Intatec Limited Airfield Industrial Estate, Hixon, Staffordshire, ST18 0PF
More informationPOTENTIAL HEALTH & SAFETY HAZARDS
Number: OH&S 18.09.1 Revision Date: 2011.06 Confined Space 1. PURPOSE 2. SCOPE 1.1. To properly designate Confined Spaces (CS) at Thompson Rivers University (TRU), to provide guidance to ensure the safety
More informationEmergency Situation Assessment
Appendix 1 Emergency Situation Assessment Emergency Situation Assessment In-coming mains electricity failure sites with generator backup Useful Information: Severity 2 Risk Rating Low / 10 Likelihood 5
More informationFIRST AID POLICY NOVEMBER 2017
HENRY CHADWICK PRIMARY SCHOOL HILL RIDWARE FIRST AID POLICY NOVEMBER 2017 TO BE REVIEWED YEARLY UNLESS CHANGES TO LAW, PERSONNEL OR SITE PRECIPITATE AN EARLIER REVIEW EPBULL NOV 2017 REVIEW DATE REVIEWER
More informationWell Disinfection NONCOMMUNITY PUBLIC WATER SUPPLY PROGRAM
Well Disinfection MINNESOTA DEPARTMENT OF HEALTH NONCOMMUNITY PUBLIC WATER SUPPLY PROGRAM When to Disinfect Well disinfection can eliminate or reduce many kinds of harmful bacteria and viruses as well
More informationHazardous substance risk management
November 2017 H E A LT H & S A F E T Y AT WO R K HSWA AC T QUICK GUIDE Hazardous substance risk management KEY FACTS You must proactively manage the risks that come from having hazardous substances in
More informationYour water byelaws explained
Your water byelaws explained welcome to your water byelaws explained Scottish Water provides clean, safe and high quality drinking water to over 150,000 business premises across Scotland. Every day we
More informationTo comply with the OHS Act, the responsible manager must carry out and document the following:
Owner: Manager Health, Wellbeing and Safety Last Update: 10 January 2018 Contents 1. Purpose... 1 2. Minimum Compliance Requirements... 1 3. Definitions... 2 4. Legislative requirements under the OHS Act
More informationHEAT, COLD, SOLAR ULTRAVIOLET & INCLEMENT WEATHER
CONTRACTOR WHS HAZARD STANDARD HEAT, COLD, SOLAR ULTRAVIOLET & INCLEMENT WEATHER EXTERNAL USE ONLY Principles in the Optus Contractor WHS management process CONTRACTOR MANAGEMENT STAGES PRINCIPLES THIS
More informationTEMPERATURE STABILISED THERMOSTATIC SHOWER PANEL
Product Support Guarantee This product is guaranteed against faulty materials and workmanship for 12 months from date of purchase. For the guarantee to be valid, the unit must be installed by a competent
More informationMATERIAL SAFETY DATA SHEET G.P. RED OXIDE PRIMER
MATERIAL SAFETY DATA SHEET G.P. RED OXIDE PRIMER 1. PRODUCT AND COMPANY IDENTIFICATION: TRADE / COMMERCIAL NAME General Purpose Red Oxide Primer CHEMICAL FAMILY Alkyd resin & aliphatic hydrocarbons UN
More informationIN-SERVICE TESTING The purpose of in-service testing is to regularly monitor the thermal performance of the thermostatic mixing valve. Deterioration in performance can indicate the need for service work
More informationHS26 Working at Height Policy and Procedure
HS26 Working at Height Policy and Procedure HS26: Working at Height Policy and Procedure v2-0.jun 2016 Page 1 of 8 1. Scope This policy applies to all staff, students and visitors to The Shared Learning
More informationA MESSAGE FROM THE MD
A MESSAGE FROM THE MD The Life Saving Rules set out clear and simple dos and don ts covering activities with the highest potential safety risk and apply to all employees and contractors. The best-performing
More informationBermad Pressure Reducing. Model: 42T
Bermad Pressure Reducing Pilot Operated Pressure Control Valve Model: 42T Installation Operation Maintenance Manual (IOM) REV. 27.7.17 Page 1 of 12 Safety First BERMAD believes that the safety of personnel
More informationOxygen Dialflow Meter. Instructions for Use
Oxygen Dialflow Meter Instructions for Use 702-0031.9 May 2014 1. Symbols Warning! Caution! Indicates a potentially hazardous situation which, if not avoided, could result in personal injury to the user
More informationOverview EUSDSG3.6. Gas tightness testing and direct purging
Overview This national occupational standard is for gas engineers who will be carrying out tightness testing and direct purging of small(domestic) natural gas installations. This standard also covers the
More information2-1- Shipping Receiving Lifting Location on Site Installation Stages 6
NEUTRAL GROUNDING RESISTORS INSTALLATION, OPERATION & MAINTENANCE MANUAL Contents 1- SAFETY INSTRUCTIONS... 3 1-1- Compliance with Instructions in this Manual. 3 1-2- Guidance Notes Installation.... 3
More informationConfined Spaces Guide
1 P a g e Confined Spaces Guide It is the responsibility of every occupant, owner, tenant, contractor, employee & visitor and ALL users of this complex to ensure they take all reasonably practical steps
More informationLONE WORKING HEALTH AND SAFETY GUIDANCE
LONE WORKING HEALTH AND SAFETY GUIDANCE Revised March 2017: Version 3.1 Name of Policy: Purpose of the Policy: Policy Applies to: Approved by: Responsible for its Updating: Final Approval by: Lone Working
More informationA Checklist for a Health and Safety Risk Assessment
A Checklist for a Health and Safety Risk Assessment Business Information Factsheet BIF376 July 2016 Introduction All employers, and certain self-employed workers and contractors, are required to assess
More informationProcedure: Pressure equipment safety
Procedure: Pressure equipment safety Purpose The purpose of this procedure is to define the method for safe operation and inspection of pressure equipment and the collection and recording of associated
More information(2) but does not include a shaft, trench or tunnel that is a mine or is part of the workings of a mine.
Health and Safety Procedure - Confined Spaces Section 1 - Background and Purpose (1) Confined spaces are, for the purposes of this procedure, defined as the following which is the definition under the
More information