1 Appendix 1 Emergency Situation Assessment Emergency Situation Assessment In-coming mains electricity failure sites with generator backup Useful Information: Severity 2 Risk Rating Low / 10 Likelihood 5 and score Failure of the electricity supply has happened on a number of occasions with durations lasting up to a few days. Minor inconvenience as some areas may lose power and high electrical demand areas such as the laundry facility at Northgate may have to be partially shut down. The failure of the in-coming electricity supply will result in a short duration where complete lack of power will occur. This will last for around 10-15s until the backup emergency generation has started, during the power outage some systems will revert to a battery backup, this includes fire alarms, intruder alarms, staff attack system, emergency lights, phones, some IT equipment. The following areas have emergency generation: Northgate Hospital St Nicholas Hospital Ferndene Monkwearmouth Hospital Hopewood Park. Maintain the condition of the emergency generators. Ensure sufficient fuel is maintained on-site to power the generator for a sustained period of up to 5 days. Ensure staff are trained in starting the generators manually in the event of a start failure. Maintain battery backup systems to sensitive equipment. Attend site during a power failure. Have capability and a contract in place to bring on site a mobile generator if necessary. Under normal circumstances the failure of the in-coming mains electrical supply is not an emergency situation for those sites where the backup generator functions. For incoming mains power failures contact Northern Power grid on For backup emergency generator contact Aggreko on

2 Risk Assessment: In-coming mains electricity failure sites without generator backup Severity 3 Risk Rating Likelihood 5 and score Moderate / 15 Failure of the electricity supply has happened on a number of occasions with durations lasting up to a few days. This will cause significant disruption to a service. Impact Assessment: The failure of the in-coming electricity supply will result in a loss of mains electricity within a building. This will impact on heating and hot water systems, power for catering and washing equipment etc. Some emergency services will revert to a battery backup, this includes fire alarms, intruder alarms, staff attack system, emergency lights, phones, some IT equipment. It should be noted that the emergency lights will fail after 3 hours and other systems will last for up to 24 hours. There is little that can be done to predict the location and duration of the mains failure. Properties will have their battery backup systems tested and maintained in accordance with good practice. Under normal circumstances a short term failure of the in-coming mains electrical supply is unlikely to create an immediate emergency situation. However, depending on a range of factors including type of occupancy, duration, time of year etc the building or service manager may wish to declare an emergency. For potentially long term power failure (determined after taking advice from Northern Power Grid) consider installation of a portable generator. Useful Information: For incoming mains power failures contact Northern Power grid on For backup emergency generator contact Aggreko on

3 Risk Assessment: Local electricity failure to an individual building or part of a site Severity 3 Risk Rating Likelihood 3 and score Low / 9 A local failure of the electricity supply can happen, however the frequency is rare. Disruption could last for a few days. This will cause significant disruption to a service. Impact Assessment: Useful Information: The local failure of the in-coming electricity supply will result in a loss of mains electricity within a building or area of a site. This will impact on heating and hot water systems, power for catering and washing equipment etc. Some emergency services will revert to a battery backup, this includes fire alarms, intruder alarms, staff attack system, emergency lights, phones, some IT equipment. It should be noted that the emergency lights will fail after 3 hours and other systems will last for up to 24 hours. Safe systems of work will be in place to ensure accidental damage to cables is minimised. Properties will have their battery backup systems tested and maintained in accordance with good practice. Ring systems provide a greater degree of power resilience in the event of a cable fault. A local failure will not activate the emergency generator. Under normal circumstances a local failure of the mains electrical supply is an emergency situation that needs to be dealt with to prevent the escalation of the incident. The severity of the emergency depends on a range of factors including type of occupancy, duration, time of year etc the building or service manager may wish to declare an emergency at an early stage. The factors leading to the power failure may also create an emergency situation, e.g. damage to a cable, theft etc. For potentially long term power failure (determined after taking advice from Northern Power Grid) consider installation of a portable generator. For backup emergency generator contact Aggreko on

4 Risk Assessment: Impact Assessment: Failure of a backup emergency generator during a mains failure. Severity 5 Risk Rating Low / 10 Likelihood 2 and score A failure of the electricity supply coupled with a failure of the backup emergency generator is possible but the occurrence is deemed to be rare. Disruption could last for just a few minutes or a few hours until either the generator is started or a replacement is brought to site. This will cause significant disruption to a service. A full site failure of the electricity supply will result in a loss of mains electricity within a site. This will impact on heating and hot water systems, power for catering and washing equipment etc. Some emergency services will revert to a battery backup, this includes fire alarms, intruder alarms, staff attack system, emergency lights, phones, some IT equipment. It should be noted that the emergency lights will fail after 3 hours and other systems will last for up to 24 hours. Maintain the condition of the emergency generators. Ensure sufficient fuel is maintained on-site to power the generator for a sustained period of up to 5 days. Ensure staff are trained in starting the generators manually in the event of a start failure. Maintain battery backup systems to sensitive equipment. Attend site during a power failure. Have capability and a contract in place to bring on site a mobile generator if necessary. Many buildings have direct generator connection points. This will be an emergency situation and prompt action is necessary. The factors leading to the power failure may also create an emergency situation, e.g. damage to a cable, fire, theft etc. For potentially long term power failure (determined after taking advice from Northern Power Grid) consider installation of a portable generator. Useful Information: For incoming mains power failures contact Northern Power grid on For backup generator contact Aggreko on

5 In-coming mains water failure Severity 4 Risk Rating Low / 8 Likelihood 2 and score Failure of the water supply has happened on a number of occasions with durations typically lasting a few hours, although a failure at Northgate Hospital lasted 3 days. Minor inconvenience in the short term as all hospital sites and most of the smaller community properties have at least 8 hours of water storage, which can be extended with water rationing. Some areas such as the laundry facility at Northgate may have to be partially shut down to conserve water. A mains water failure will have a delayed impact due to the storage capacity on site. When the stored water runs out this will escalate to an emergency situation as the impact will be on toilet flushing, hand washing, bathing, food preparation, cleaning, steam systems, drinking water etc. The details of the failure should be ascertained from Northumbrian water at the earliest opportunity and the details passed up the chain of command. Maintain the condition of the site water storage tanks and ensure sufficient capacity is retained for emergency use. Maintain access for emergency tanker deliveries direct into water storage tanks, Useful Information: Northumbrian water have the details of all hospital sites. In an emergency situation they will prioritise tanker deliveries of water to hospital sites. They can also arrange for bottles of water for drinking to be delivered to drop off points on the hospital. For problems with water or sewerage contact Northumbrian Water Leaks Sewerage system floods

6 Local mains water failure Severity 3 Risk Rating Low / 9 Likelihood 3 and score Localised failure of the water supply has happened on a number of occasions with durations typically lasting a few hours. Minor inconvenience in the short term, however this will escalate to a major inconvenience within a few hours. A localised mains water failure will have an immediate impact due to limited storage within buildings. This will escalate to an emergency situation as the impact will be on toilet flushing, hand washing, bathing, food preparation, cleaning, steam systems, drinking water etc. The estates department can repair leaks / fractured pipes. The details of the failure should be ascertained at the earliest opportunity and the details passed up the chain of command. Monitor site water consumption on an on-going basis and trend night time flow rates to determine if leaks exist and repair as necessary. Maintain equipment on site to fix burst mains or fractured pipes. The Trust can purchase bottles water relatively easily from suppliers for drinking purposes. Useful Information: For major failure Northumbrian water have the details of all hospital sites and in an emergency situation they will prioritise tanker deliveries of water to hospital sites. They can also arrange for bottles of water for drinking to be delivered to drop off points on the hospital. For problems with water or sewerage contact Northumbrian Water. Leaks Sewerage system floods

7 Water contamination Severity 5 Risk Rating Likelihood 1 and score Low / 5 Contamination of the incoming water supply is unlikely The details of the failure should be ascertained from Northumbrian water at the earliest opportunity and the details passed up the chain of command. Maintain the condition of the site water storage tanks and ensure sufficient capacity is retained for emergency use. Maintain access for emergency tanker deliveries direct into water storage tanks, If the Water Authority advises that the supply has been seriously contaminated or the tanks have been contaminated on site, it is important to: Isolate at the outgoing side of the storage tanks Drain the water supply mains via the fire hydrants Whilst informing all concerned in 5(a) above. If necessary delegate various staff to different telephones to inform all Wards/Departments concerned by working through the internal telephone directory as appropriate. Use bottled water for drinking Catering Manager to arrange additional supplies of bottled water Take advice on the nature of the contamination from the Water Authority and liaise with medical, nursing and control of infection staff. Samples from the storage tanks may be required for immediate analysis. If a contaminant can be identified and the manufacturer is known take advice from the manufacturer, preferably by . It may be necessary isolating the incoming and outgoing pipework of the storage tanks by disconnection and verifying the water quality before use. Take appropriate measures to decontaminate tanks and pipework and ensure quality tests are satisfactory before restoring the supply in conjunction with the advisory and statutory authorities. Northumbrian water have the details of all hospital sites. In an emergency situation they will prioritise tanker deliveries of water to hospital sites. They can also arrange for bottles of water for drinking to be delivered to drop off points on the hospital. 7

8 Useful Information: For problems with water or sewerage contact Northumbrian Water Leaks Sewerage system floods Emergency Situation Assessment Failure of the sewerage and drainage systems Severity 4 Risk Rating Likelihood 2 and score Low / 8 Failure of the sewerage supply has happened on a number of occasions with durations typically lasting a few hours, although off site failures could potentially last longer. Minor inconvenience in the short term A sewerage system failure will have a delayed impact due to the small storage capacity within the drainage system on site. When the system reaches capacity this will escalate to an emergency situation as the impact could be on localised flooding, toilets / sanitary facilities unable to drain etc. The details of the failure should be ascertained from site investigations and if an off site problem is ascertained contact Northumbrian water at the earliest opportunity and the details passed up the chain of command. A foul drain failure could lead to land or river contamination from raw sewerage. Maintain the condition of the site drainage infrastructure ensuring gulley s are cleared. Carry out periodic CCTV surveys and ensure remedial work is undertaken. In an emergency situation such as a collapsed drain, consider bringing in a tanker to pump the sewerage away until the drain is repaired. For a site based issue in an emergency situation such as a collapsed drain, consider bringing in a tanker to pump the sewerage away until the drain is repaired. Useful Information: For problems with water or sewerage contact Northumbrian Water Sewerage system floods

9 In-coming mains gas failure sites with partial backup Severity 3 Risk Rating Low / 3 Likelihood 1 and score Failure of the in-coming gas main in a major conurbation is rare, consequently the risk of this occurring is low. For Hopewood Park and St Nicholas Hospital the main boilerplant can run on oil and sufficient storage of oil is maintained on site. St Nicholas Hospital has an interruptible gas contract which means the supply to the main boilers can be isolated with 4 hours notice. In these circumstances switchover to oil is necessary. At Ferndene heating can be provided by the air source heat pumps, however, there will be no hot water. A gas main failure is rare. In the context of SNH, Hopewood Park and Ferndene the impact will be minimised due to the backup systems. However, in each case their coverage is limited as follows: SNH Main boilerplant covers around 75% of the site, with many of the peripheral buildings having no backup HP Main boilerplant covers most of the Hopewood Park part of the site but not the Ryhope buildings such as the Grove etc Ferndene backup provides heating only. The details of the failure should be ascertained from National Grid at the earliest opportunity and the details passed up the chain of command. Test the oil firing capabilities on a regular basis of the backup systems Retain sufficient fuel on site 9

10 Useful Information: Contact National Grid for gas emergencies on Emergency Situation Assessment In-coming mains gas failure sites / buildings without backup Severity 5 Risk Rating Low / 5 Likelihood 1 and score Failure of the in-coming gas main in a major conurbation is rare and consequently the risk of this occurring is low. With the exception of those sites with oil backup on central plant or those with heat pumps a gas main failure will impact on all sites, although due to the spread out nature of the Estate not all at once. A gas main failure is rare. In the context of SNH, Hopewood Park and Ferndene the impact will be minimised due to the backup systems. However, in each case their coverage is limited. A gas main failure will have significant impact on the running of the building, the scale of this will be dependant on factors such as the time of year and duration of the failure. The major impact will be no heating or hot water. The details of the failure should be ascertained from National Grid at the earliest opportunity and the details passed up the chain of command. A small amount of local electric heaters could be used in an individual building. However, this strategy is not suitable for large scale deployment as the electrical infrastructure would be overloaded. Useful Information: Contact National Grid for gas emergencies on

11 Useful Information: Heating / hot water System Failure Severity 4 Risk Rating Low / 8 Likelihood 2 and score Failure of a buildings heating / hot water system can happen due to a range of factors including: BMS failure Gas valve tripped Pump problem Boiler problem A heating / hot water system failure will have a delayed impact due to the stored energy within the system. However, as the failure is usually reported when occupants notice it is either becoming cold or the hot water has run out, this delay benefit is usually minimised. A heating / hot water system failure will have a significant impact on the running of the building, the scale of this will be dependant on factors such as the time of year and duration of the failure. The major impact will be no heating or hot water. The details of the failure should be ascertained from at the earliest opportunity and the details passed up the chain of command. Ensure plant is serviced and maintained in accordance with the PPM schedules and recognised good practice. Ensure relevant service contracts are in place. Ensure relevant spare parts are available. A small amount of local electric heaters could be used in an individual building. However, this strategy is not suitable for large scale deployment as the electrical infrastructure would be overloaded. Temporary mobile oil fired boilerplant could be utilised CWS Engineers Limited Empire Facilities Management Andrews Sykes (boiler hire) 11

12 Gas Leak Severity 5 Risk Rating Likelihood 1 and score Low / 5 Gas leaks are rare, however the severity under the right circumstances can be significant. Although gas is now typically piped underground to many wards on various site, there is normally only a limited amount of gas pipework inside a building. The procedure for a building with gas inside will be displayed on a notice. Gas can leak from underground pipes and into buildings. When this occurs and there is a smell of gas. Gas explosions, whilst rare, can be catastrophic causing both explosion and fire. The details of the failure should be ascertained from National Grid at the earliest opportunity and the details passed up the chain of command. Plant and equipment to be fully serviced by qualified contractors, in accordance with legislation, manufacturers guidelines and any other relevant documentation. Open all doors and windows and ventilate the area Extinguish all naked lights Do not allow power or lighting points to be switched on or off Evacuate the premises if considered necessary Go to a telephone (not in the premises) and contact the duty officer The duty officer will contact the on call engineer who will action the work on site NB Any smell of gas on this site must be reported as an EMERGENCY 12

13 Useful Information: Contact National Grid for gas emergencies on

Facilities and Estates. Natural Gas: Standard Operating Procedure. Document Control Summary. Contents

Facilities and Estates. Natural Gas: Standard Operating Procedure. Document Control Summary. Contents Facilities and Estates Natural Gas: Standard Operating Procedure Document Control Summary Status: Version: Author/Title: Owner/Title: Approved by: Ratified: Related Trust Strategy and/or Strategic Aims

More information

PRESSURE SYSTEMS POLICY

PRESSURE SYSTEMS POLICY PRESSURE SYSTEMS POLICY PRESSURE SYSTEMS POLICY 1. Introduction 2. Policy Statement 3. Scope 4. Background 5. Roles & Responsibilities 6. Training 7. Contractors 8. Policy Review 1. Introduction The Kilmarnock

More information

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant Health and Safety Executive Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant Background Accidents involving

More information

Best Practice Guideline EMERGENCY PROCEDURE FOR A QUARRY

Best Practice Guideline EMERGENCY PROCEDURE FOR A QUARRY Best Practice Guideline EMERGENCY PROCEDURE FOR A QUARRY www.aspasa.co.za February 2015 Aspasa has developed a draft procedure to provide the basis for an effective emergency procedure for a quarry. This

More information

METHODOLOGY RISK TABLES TABLE 1 - QUALITATIVE MEASURES OF CONSEQUENCE OR IMPACT TABLE 2 - QUALITATIVE MEASURES OF LIKELIHOOD

METHODOLOGY RISK TABLES TABLE 1 - QUALITATIVE MEASURES OF CONSEQUENCE OR IMPACT TABLE 2 - QUALITATIVE MEASURES OF LIKELIHOOD METHODOLOGY This Assessment has been performed as outlined in Australian Standard AS/NZS ISO 31000:2009 with reference to tables 1, 2 and 3 below, for the use of leased land for the purposes of performing

More information

IMMANUEL CHURCH, CHICHESTER HEALTH AND SAFETY POLICY

IMMANUEL CHURCH, CHICHESTER HEALTH AND SAFETY POLICY IMMANUEL CHURCH, CHICHESTER HEALTH AND SAFETY POLICY Approved by the Trustees: November 2016 Health and Safety Policy Introduction The main piece of health and safety legislation is the Health and Safety

More information

Operation and Maintenance manual Issue No: 1 Issue Date: 4th September 2007

Operation and Maintenance manual Issue No: 1 Issue Date: 4th September 2007 Operation and Maintenance manual Document Title: Purewater CWST O&M Issue No: 1 Issue Date: 4th September 2007 This manual is to be used in conjunction with the following products manufactured by Purewater

More information

Health and Safety Inspection Procedure

Health and Safety Inspection Procedure Template v4 WILTSHIRE POLICE FORCE PROCEDURE Health and Safety Inspection Procedure Effective from: 25.03.2012 Last Review Date: 10.05.2015 Version: 2.0 Next Review Date: 10.05.2018 TABLE OF CONTENTS PROCEDURE

More information

Release: 1. UEPOPL002A Licence to operate a reciprocating steam engine

Release: 1. UEPOPL002A Licence to operate a reciprocating steam engine Release: 1 UEPOPL002A Licence to operate a reciprocating steam engine UEPOPL002A Licence to operate a reciprocating steam engine Modification History Not applicable. Unit Descriptor Unit Descriptor 1)

More information

A little technical and safety...

A little technical and safety... A little technical and safety... Please familiarise yourself with the contents of this booklet as it references the safety of your tank installation and safe supply of LPG. Please also keep to hand a note

More information

Allowances, Assessment Requests and Incentive Payments. U pdated - 3 rd October 2016

Allowances, Assessment Requests and Incentive Payments. U pdated - 3 rd October 2016 Allowances, Assessment Requests and Incentive Payments U pdated - 3 rd October 2016 Allowances, Assessment Requests and Incentive Payments Why The wholesale Allowances, Assessment Requests and Incentive

More information

Instructions for the Use of the Excel Spreadsheet. There are Three tabs at the bottom of this worksheet. Instructions tab is the one you are reading

Instructions for the Use of the Excel Spreadsheet. There are Three tabs at the bottom of this worksheet. Instructions tab is the one you are reading Instructions for the Use of the Excel Spreadsheet There are Three tabs at the bottom of this worksheet Instructions tab is the one you are reading H&S Plan Tab The Plan Tab is the front cover pages of

More information

BOC Healthcare Training

BOC Healthcare Training BOC Healthcare Training BOC Healthcare Training Because you need to be certain BOC: Living healthcare BOC: Living Healthcare 03 Medical Engineering Services Medical Engineering Services has been designed

More information

Low Voltage Electricity System Safety Rules & Associated Safety Guidance

Low Voltage Electricity System Safety Rules & Associated Safety Guidance Annex J To Loughborough University Facilities Management (FM) Health and Safety Policy Low Voltage Electricity System Safety Rules & Associated Safety Guidance 1. Introduction a. These Safety Rules are

More information

CODE OF PRACTICE 42 IMPLEMENTATION OF EIGA CARBON DIOXIDE STANDARDS REVISION 2: 2018

CODE OF PRACTICE 42 IMPLEMENTATION OF EIGA CARBON DIOXIDE STANDARDS REVISION 2: 2018 CODE OF PRACTICE 42 IMPLEMENTATION OF EIGA CARBON DIOXIDE STANDARDS REVISION 2: 2018 CODE OF PRACTICE 42 IMPLEMENTATION OF EIGA CARBON DIOXIDE STANDARDS REVISION 2: 2018 Copyright 2018 by British Compressed

More information

IMPLEMENTATION OF EIGA CARBON DIOXIDE STANDARDS

IMPLEMENTATION OF EIGA CARBON DIOXIDE STANDARDS CODE OF PRACTICE 42 IMPLEMENTATION OF EIGA CARBON DIOXIDE STANDARDS REVISION 1 : 2014 CODE OF PRACTICE 42 IMPLEMENTATION OF EIGA CARBON DIOXIDE STANDARDS REVISION 1: 2014 Copyright 2014 by British Compressed

More information

BOC Healthcare training

BOC Healthcare training BOC Healthcare training BOC Healthcare training Because you need to be certain BOC: Living healthcare BOC Healthcare training 03 Medical Engineering Services Medical Engineering Services has been designed

More information

Pollution Incident Response Management Plan

Pollution Incident Response Management Plan Pollution Incident Response Management Plan 27 Foundation Rd, Truganina 3029 Nov 2016 Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. Pollution Incident Response Management Plan 1 What is "the

More information

Bogo Operations Pollution Incident Response Management Plan

Bogo Operations Pollution Incident Response Management Plan Bogo Operations Pollution Incident Response Management Plan Rhyolite Hard Rock Aggregate Quarry 134 Paynes Road BOOKHAM NSW 2582 PO Box 426 COWRA NSW 2794 p: 02 6227 7260 p: 02 6345 4253 e: info@bogoquarry.com.au

More information

Yorkshire Water Wholesale Allowances Policy

Yorkshire Water Wholesale Allowances Policy Yorkshire Water Wholesale Allowances Policy of the Contents Purpose... 3 Scope... 3 Assurance... 3 Approach... 3 Principles... 3 Contact details... 6 Version control... 6 2 Purpose The purpose of this

More information

SOAS LONE WORKING GUIDANCE

SOAS LONE WORKING GUIDANCE SOAS LONE WORKING GUIDANCE Introduction This guidance is intended to assist managers and heads of department in assessing the risks associated with lone working and their staff. While there are no specific

More information

Lifting Equipment Procedure. Committees / Group Date Consultation: Health and Safety Sub Committee Nov 2016

Lifting Equipment Procedure. Committees / Group Date Consultation: Health and Safety Sub Committee Nov 2016 Title of Standard Operation Procedure: Lifting Equipment Procedure ocedure: Person(s) responsible for the Health and Safety Manager production of report e Reference Number: H&S Procedure 16 Version No:

More information

3. PURPOSE: To establish the minimum safety content of swimming pool Operations Manuals.

3. PURPOSE: To establish the minimum safety content of swimming pool Operations Manuals. GO.. TITLE: OPERATIONS MANUALS 2. DATE ISSUED: July 996 ISSUE: 2 3. PURPOSE: To establish the minimum safety content of swimming pool Operations Manuals. 4. (a) An Operations Manual should be prepared

More information

Introduction. Legal Duties. Risk Assessment

Introduction. Legal Duties. Risk Assessment All Hampstead Hill School Policies are always to be read and considered in conjunction with Equal Opportunities, Race Equality and Inclusion Policies. This Policy of Hampstead Hill School applies to all

More information

Legionella Guidance. Property managers specialising in residential, apartment, block and estate management

Legionella Guidance. Property managers specialising in residential, apartment, block and estate management Legionella Guidance Legionnaires disease is a potentially fatal lung infection - pneumonia, that is caused by the legionella bacteria. It can be caught by breathing in small droplets of contaminated water.

More information

Emergency Response Plans

Emergency Response Plans PO Box 2114 Woonona East NSW 2517 (WOLLONGONG) PTY LTD Ph: 0417 420 760 Fax: 02 4283 2216 A/H: 02 4283 7727 EPA Licence: 11788 ABN: 57 079 336 799 Unit 11 Lot 1 York Place Woonona NSW 2517 Emergency Response

More information

Introduction to Emergency Response & Contingency Planning

Introduction to Emergency Response & Contingency Planning & Contingency Planning Rationale Why is it important for you to learn this material? Designed for those who may witness a release, this is an introductory course designed to help ensure those who are likely

More information

Laboratory Preparedness Checklists for Advanced Planning, Preparing to Close & Safe Re-Entry

Laboratory Preparedness Checklists for Advanced Planning, Preparing to Close & Safe Re-Entry Laboratory Preparedness Checklists for Advanced Planning, Preparing to Close & Safe Re-Entry Disruptions, utility outages, and severe weather events may require a laboratory closure. These events have

More information

Hazard & Risk Management

Hazard & Risk Management Hazard & Risk Management Introduction The Church recognises WHS hazards and risks must be appropriate managed to ensure, so far as reasonably practicable, the health and safety of all workers at Church

More information

ECD-HS-PR (Reviewed November 2015) Confined Spaces Policy.

ECD-HS-PR (Reviewed November 2015) Confined Spaces Policy. ECD-HS-PR-002-0211 (Reviewed November 2015) Confined Spaces Policy. Date: November 2015 Review: November 2016 Forward: This document and associated appendix has been developed by Aston University Estates

More information

Plant Isolation Lock out/tag out Procedure

Plant Isolation Lock out/tag out Procedure Plant Isolation Lock out/tag out Procedure Related Policy Responsible Officer Approved by Work Health and Safety Policy Approved and commenced November, 2014 Review by November, 2017 Responsible Organisational

More information

E PGN-11. Part of NTW (O)32 Estates Operations and Maintenance Policy Paul McCabe Head of Estates and Facilities-NTW Solution Ltd

E PGN-11. Part of NTW (O)32 Estates Operations and Maintenance Policy Paul McCabe Head of Estates and Facilities-NTW Solution Ltd Estates Operations and Maintenance Practice Guidance Note Management of Pressure Systems V01 Date Issued Planned Review PGN No: Issue 1 - Nov 2015 Issue 2 Nov 2017 Author / Designation Responsible Officer

More information

LOCKOUT SYSTEM AND POLICIES

LOCKOUT SYSTEM AND POLICIES LOCKOUT SYSTEM AND POLICIES Lockout System Purpose Employees health and safety takes top priority. Isolating hazardous energy to prevent sudden and unexpected energisation of machines, equipment, and processes

More information

EXECUTIVE SHIP MANAGEMENT PTE LTD M 24 Q 4 SINGAPORE QI 19 Page 1 of 5 (9/05 Rev 2) Decision. Implement

EXECUTIVE SHIP MANAGEMENT PTE LTD M 24 Q 4 SINGAPORE QI 19 Page 1 of 5 (9/05 Rev 2) Decision. Implement SINGAPORE QI 19 Page 1 of 5 RISK ASSESSMENT Ships Name Ships No Work Activity Activity / Operation Analyse/review/Assess WHAT IF? MAIN AIR COMPRESSOR OVERHAUL Possible Consequence / Hazard / Impact Monitor

More information

SEMEM3-73 Maintaining medical gas pipeline systems and equipment

SEMEM3-73 Maintaining medical gas pipeline systems and equipment Maintaining medical gas pipeline systems and equipment Overview This unit identifies the competences you need to carry out maintenance activities on medical gas pipeline systems and equipment, in accordance

More information

MEDICAL GAS CYLINDERS AND MEDICAL PIPELINE SYSTEMS (MGPS) POLICY

MEDICAL GAS CYLINDERS AND MEDICAL PIPELINE SYSTEMS (MGPS) POLICY MEDICAL GAS CYLINDERS AND MEDICAL PIPELINE SYSTEMS (MGPS) POLICY Version: 4 Date issued: April 2018 Review date: April 2021 Applies to: All staff (excluding office and clerical staff) This document is

More information

Gas Interruptions. customer guide

Gas Interruptions. customer guide Gas Interruptions customer guide December 2006 Dear Customer Gas Interruptions Customer Guide We have produced this guide for customers who take interruptible gas supplies from us. The new gas year commences

More information

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation. Quality Products at Competitive Prices Gas Check Automatic testing of the down-stream installation to check that all valves are closed and that pipework and fittings are gas tight before each system start-up.

More information

Public. Water Supply Emergency Response Plan For The. Village of Clayton Water Treatment Facility. Public Water System I.D. No.

Public. Water Supply Emergency Response Plan For The. Village of Clayton Water Treatment Facility. Public Water System I.D. No. Public Water Supply Emergency Response Plan For The Village of Clayton Water Treatment Facility Public Water System I.D. No.: NY2202335 Population Served: 2,012 Address: 425 Mary Street Clayton, NY 13624

More information

Managing Leakage and Preparing for the 2012 Olympics

Managing Leakage and Preparing for the 2012 Olympics Water UK Leakage Conference 2012 Managing Leakage and Preparing for the 2012 Olympics Andrew Oakes Thames Water - Leakage Planning Manager Steven Harvey Thames Water - Asset Modelling and Design Specialist

More information

User Information Sheet 015

User Information Sheet 015 User Information Sheet 015 Formerly LPGA Guidance NO.84 March 2007 Inspection and Maintenance of LPG Pipework at Commercial and Industrial Premises 1. Introduction LPG pipework may, under certain conditions,

More information

I. Subject: Medical Gas Systems Utility Failure Interim Procedure III. Purpose:

I. Subject: Medical Gas Systems Utility Failure Interim Procedure III. Purpose: I. Subject: Medical Gas Systems Utility Failure Interim Procedure II. Purpose: To provide a systematic response to medical gas system failure and restoration of this critical utility. III. Procedure: Systems

More information

Copyright Thames Water Utilities Ltd Alternative water supplies policy.

Copyright Thames Water Utilities Ltd Alternative water supplies policy. Alternative water supplies policy. Version 1.3 Publish Date: 21 February 2017 Effective from: 1 April 2017 Public Contents 1. Background... 4 2. Scope... 4 3. Definition of terms... 4 4. Principles...

More information

THE UNIVERSITY OF SHEFFIELD ACCIDENT AND INCIDENT REPORTING AND INVESTIGATION POLICY AND PROCEDURES

THE UNIVERSITY OF SHEFFIELD ACCIDENT AND INCIDENT REPORTING AND INVESTIGATION POLICY AND PROCEDURES THE UNIVERSITY OF SHEFFIELD ACCIDENT AND INCIDENT REPORTING AND INVESTIGATION POLICY AND PROCEDURES Page 1 of 10 Document Created November 2012 CONTENTS Page No 1 INTRODUCTION 3 2 REPORTING ACCIDENTS,

More information

Periodic Survey of Fuel Installations on Ships other than Liquefied Gas Carriers utilizing gas or other low flash point fuels

Periodic Survey of Fuel Installations on Ships other than Liquefied Gas Carriers utilizing gas or other low flash point fuels (Jan 2017) Periodic Survey of Fuel Installations on Ships other than Liquefied Gas Carriers utilizing gas or other low flash point fuels CONTENTS 1. Application 2. Special Survey 2.1 Schedule 2.2 Scope

More information

General Policies July Hydrotherapy Pool Policy

General Policies July Hydrotherapy Pool Policy Hydrotherapy Pool Policy HYDROTHERAPY POOL POLICY Contra-indications to a User with the advice of a Doctor, the School Nurse and/or Physiotherapist: Infectious skin disease Infectious upper respiratory

More information

DISTRIBUTION, OPERATION and MAINTENANCE STRATEGY ASSET MANAGEMENT WORK PROCEDURE COMMUNICATION PIPE REPAIRS

DISTRIBUTION, OPERATION and MAINTENANCE STRATEGY ASSET MANAGEMENT WORK PROCEDURE COMMUNICATION PIPE REPAIRS DISTRIBUTION, OPERATION and MAINTENANCE STRATEGY COMMUNICATION PIPE REPAIRS Document Title: Work Procedure Communication Pipe Repairs Document Reference: DOM-WN-PRC-00000308 Date: October 2013 Approved

More information

Policies, Procedures, Guidelines and Protocols

Policies, Procedures, Guidelines and Protocols Policies, Procedures, Guidelines and Protocols Document Details Title Portable Electrical Equipment Management Policy Trust Ref No 701-29768 Local Ref (optional) Main points the document Responsibilities

More information

Health and Safety Policy

Health and Safety Policy Snowflake School Policy Reviewed September 2018 To be reviewed September 2019 Roy English Health and Safety Policy 1. STATEMENT OF INTENT The Trustees of Snowflake School will take steps to meet their

More information

PLANNED LIGHTING MAINTENANCE LTD METHOD STATEMENT & RISK ASSESSMENT REPLACEMENT OF LAMPS OR REPAIRS TO HIGH LEVEL LIGHT UNITS

PLANNED LIGHTING MAINTENANCE LTD METHOD STATEMENT & RISK ASSESSMENT REPLACEMENT OF LAMPS OR REPAIRS TO HIGH LEVEL LIGHT UNITS PLANNED LIGHTING MAINTENANCE LTD METHOD STATEMENT & RISK ASSESSMENT REPLACEMENT OF LAMPS OR REPAIRS TO HIGH LEVEL LIGHT UNITS Project: (insert Client) Replacement/ Repair of high level light units/ high

More information

In Vessel Composter Installation & Commissioning Manual

In Vessel Composter Installation & Commissioning Manual In Vessel Composter Installation & Commissioning Manual Contents Customer responsibilities Transportation Lifting Delivery Pre-installation requirements Installation Drainage Ventilation Levelling Unpacking

More information

POLICY ON THE PROVISION & USE OF PERSONAL PROTECTIVE EQUIPMENT

POLICY ON THE PROVISION & USE OF PERSONAL PROTECTIVE EQUIPMENT POLICY ON THE PROVISION & USE OF PERSONAL PROTECTIVE EQUIPMENT June 2013 Lead Manager John Green, Health & Safety Service Manager Responsible Director Director of Human Resources Approved By Health and

More information

PLANNED LIGHTING MAINTENANCE LTD METHOD STATEMENT & RISK ASSESSMENT REPLACEMENT OF LAMPS OR REPAIRS TO LOW LEVEL LIGHT UNITS

PLANNED LIGHTING MAINTENANCE LTD METHOD STATEMENT & RISK ASSESSMENT REPLACEMENT OF LAMPS OR REPAIRS TO LOW LEVEL LIGHT UNITS PLANNED LIGHTING MAINTENANCE LTD METHOD STATEMENT & RISK ASSESSMENT REPLACEMENT OF LAMPS OR REPAIRS TO LOW LEVEL LIGHT UNITS Project: Insert Client Repair/ Replacement of low level light units/ low level

More information

Gas Safety Code of Practice

Gas Safety Code of Practice Gas Safety Code of Practice Reviews and Revisions Action Date Reason Reviewer Gas Safety Code of Practice 1 Contents Reviews and Revisions... 1 1. Code of Practice Statement... 3 2. Introduction... 4 3.

More information

Flammability Chart. Gas Formula Ignition

Flammability Chart. Gas Formula Ignition Leak Detection 101 Investigating a leak is simplified if you know the basics. By J. Scott Kleppe Sensit (J and N Enterprises, Inc.) Every day new gas services are added to provide economical energy to

More information

Safety management The Firefighter Safety Maxim Risk assessment at an incident Tactical mode Emergency evacuation and tactical withdrawal

Safety management The Firefighter Safety Maxim Risk assessment at an incident Tactical mode Emergency evacuation and tactical withdrawal Safety management... 2 The Firefighter Safety Maxim... 2 Risk assessment at an incident... 3 Risk concepts... 3 Dynamic risk assessment... 4 Analytical risk assessment... 7 Personal (or individual) risk

More information

DISTRIBUTION, OPERATION and MAINTENANCE STRATEGY ASSET MANAGEMENT WORK INSTRUCTION ISOLATION OF A WATER NETWORK

DISTRIBUTION, OPERATION and MAINTENANCE STRATEGY ASSET MANAGEMENT WORK INSTRUCTION ISOLATION OF A WATER NETWORK Document Title: Work Instruction Isolation of a Water Network Document Reference: DOM-WN-WIN-00000302 Approved By: Asset Management Title: General Manager Record of Changes and Amendments Amendment No.

More information

2. IMMEDIATE RESPONSE ACTIONS AND NOTIFICATION PROCEDURES

2. IMMEDIATE RESPONSE ACTIONS AND NOTIFICATION PROCEDURES 2. IMMEDIATE RESPONSE ACTIONS AND NOTIFICATION PROCEDURES This section of the GOSRP provides the general procedures to be followed at the time of an incident. The section is distinctively marked by a RED

More information

2 FUSION FITTINGS FOR USE WITH POLYETHYLENE PRESSURE PIPES DESIGN FOR DYNAMIC STRESSES

2 FUSION FITTINGS FOR USE WITH POLYETHYLENE PRESSURE PIPES DESIGN FOR DYNAMIC STRESSES Industry Guidelines Part 2 FUSION FITTINGS FOR USE WITH POLYETHYLENE PRESSURE PIPES DESIGN FOR DYNAMIC STRESSES ISSUE 5.1 Ref: POP10B 15 MAR 2010 Disclaimer In formulating this guideline PIPA has relied

More information

Installation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve

Installation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve Installation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve TMV3 / TMV2 Combined Valve C85079 C85081 C85080 C85082 It is important that these guidance notes are read and fully understood

More information

Examples of pressure systems and equipment are:

Examples of pressure systems and equipment are: Pressure systems Safety and you Introduction If pressure equipment fails in use, it can seriously injure or kill people nearby and cause serious damage to property. Each year in Great Britain, there are

More information

SUP 15 Health & Safety Management Pressure Systems. Unified procedures for use within NHS Scotland

SUP 15 Health & Safety Management Pressure Systems. Unified procedures for use within NHS Scotland SUP 15 Health & Safety Management Pressure Systems Unified procedures for use within NHS Scotland September 2015 Contents Page Acknowledgements... 3 1. Introduction... 4 2. Purpose of this Procedure...

More information

HUNTER ICE SKATING STADIUM RISK ASSESSMENT FOR SCHOOL SPORT GROUPS ICE SKATING

HUNTER ICE SKATING STADIUM RISK ASSESSMENT FOR SCHOOL SPORT GROUPS ICE SKATING HUNTER ICE SKATING STADIUM DIOIX" * f*f*f f*f*mmf**.*!* RISK ASSESSMENT FOR SCHOOL SPORT GROUPS ICE SKATING 2005 Introduction This Risk Assessment has been prepared for school groups who come to the Hunter

More information

General maintenance engineering applications

General maintenance engineering applications Unit 068 General maintenance engineering applications Level: 2 Credit value: 12 NDAQ number: 500/9514/6 Unit aim This unit covers the skills and knowledge needed to prove the competences required to cover

More information

Welcome to Flogas. Metered Estates. You would never know you were off the grid. Metered Estates Welcome Pack.indd 1 18/01/ :48

Welcome to Flogas. Metered Estates. You would never know you were off the grid. Metered Estates Welcome Pack.indd 1 18/01/ :48 Welcome to Flogas Metered Estates You would never know you were off the grid. Metered Estates Welcome Pack.indd 1 18/01/2016 16:48 Welcome to Flogas Metered Estates Why Flogas is the right choice A leading

More information

RULES PUBLICATION NO. 119/P

RULES PUBLICATION NO. 119/P RULES PUBLICATION NO. 119/P PERIODIC SURVEYS OF FUEL INSTALLATIONS ON SHIPS OTHER THAN LIQUEFIED GAS CARRIERS UTILIZING GAS OR OTHER LOW FLASH POINT FUELS 2019 January Publications P (Additional Rule Requirements)

More information

Isolation Lockout and Tagging

Isolation Lockout and Tagging PURPOSE To define the minimum system requirements for isolation of plant and equipment from hazardous substances, mechanical, electrical or other energy sources to protect all workers from personal injury

More information

New AQF Filter Polymer Filtration System

New AQF Filter Polymer Filtration System New AQF Filter Polymer Filtration System Operator Manual Covering Serial Number 20002001 onwards February 2011 Index Disclaimer notice...3 Introduction...4 Important safety notices...5 Getting started...6

More information

Intamix Thermostatic Mixing Valve

Intamix Thermostatic Mixing Valve Intamix Thermostatic Mixing Valve TMV2 & TMV3 Installation Guide Intatec Ltd Airfield Industrial Estate Hixon Staffordshire ST18 0PF In this procedure document we have endeavoured to make the information

More information

SAFETY MANAGEMENT SYSTEM

SAFETY MANAGEMENT SYSTEM Equipment Location: Hazard Hired From All Master Hire Stores Entanglement Can anyone s hair, clothing, gloves, necktie, jewellery, cleaning brushes, rags or other materials become entangled with moving

More information

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014 User Manual 1 P a g e Rev. V1.6-EN 11/08/2014 Copyright Disclaimer Trademarks and patents Intended use Contact info 2011 Inflotrolix, Inc. This document may not be copied in whole or in part or otherwise

More information

Steam System Best Practices 14 Best Practices for Guide Lines for Boiler Plant Log Books

Steam System Best Practices 14 Best Practices for Guide Lines for Boiler Plant Log Books Steam System Best Practices 14 Best Practices for Guide Lines for Boiler Plant Log Books 1. SCOPE OF BOILER LOGBOOK PROGRAM In all cases, there are minimum tasks and functions for an operator to perform

More information

VALVE CRITICALITY MODELING

VALVE CRITICALITY MODELING Casey, R., Boulos, P., Orr, C., and Bros, C. (2008). Valve Criticality Modeling. Eighth Annual ASCE Water Distribution Systems Analysis Symposium, Cincinnati, Ohio, August 27-30, 2006: pp. 1-8. VALVE CRITICALITY

More information

Apollo Safety Features

Apollo Safety Features Overview of Emergency Start Mains Power Failure Gas Supply Failure Ventilator Failure Fresh Gas Delivery Failure Ventilator and Fresh Gas Delivery Failure Display Failure User Interface Failure System

More information

Cooling Tower Legionella Risk Assessment Checklist

Cooling Tower Legionella Risk Assessment Checklist Cooling Tower Legionella Risk Assessment Checklist Introduction This cooling tower legionella risk assessment checklist template is designed to help the responsible person audit the arrangements in place

More information

INSPECTIONS OF THE LPG ESTABLISHMENTS IN PORTUGAL. Graça Bravo. 26th September 2017

INSPECTIONS OF THE LPG ESTABLISHMENTS IN PORTUGAL. Graça Bravo. 26th September 2017 INSPECTIONS OF THE LPG ESTABLISHMENTS IN PORTUGAL Graça Bravo 26th September 2017 SUMMARY 1. IDENTIFICATION OF THE LPG ESTABLISHMENTS 2. GENERAL DESCRIPTION OF THE LPG ESTABLISHMENT 3. INSPECTION SUPPORTING

More information

LEGIONELLA MANAGEMENT PROCEDURE

LEGIONELLA MANAGEMENT PROCEDURE LEGIONELLA MANAGEMENT PROCEDURE This procedure sets out the aims and objectives of the school and outlines responsibilities for managing the risk of exposure to legionella. General Statement of Intent

More information

LONE WORKING HEALTH AND SAFETY GUIDANCE

LONE WORKING HEALTH AND SAFETY GUIDANCE LONE WORKING HEALTH AND SAFETY GUIDANCE Revised March 2017: Version 3.1 Name of Policy: Purpose of the Policy: Policy Applies to: Approved by: Responsible for its Updating: Final Approval by: Lone Working

More information

WHAT IS A RELEASE OF AMMONIA?

WHAT IS A RELEASE OF AMMONIA? WHAT IS A RELEASE OF AMMONIA? THE AMMONIA GROUP P.O. BOX 600 ALTA, CA 95701 mikectag@colfaxnet.com BEFORE WE START The ammonia industry has suffered 3 fatal accidents this month. Take a moment and think

More information

Deluge Optimo Shower valve and kit 10032CP

Deluge Optimo Shower valve and kit 10032CP Deluge Optimo Shower valve and kit 10032CP Installation, Operation and Maintenance Please leave these instructions with the user Intatec Limited Airfield Industrial Estate, Hixon, Staffordshire, ST18 0PF

More information

NATURAL GAS DISTRIBUTION SYSTEM MAYOR: ROBERT BOB HARDY OPERATOR: MICHAEL WARREN

NATURAL GAS DISTRIBUTION SYSTEM MAYOR: ROBERT BOB HARDY OPERATOR: MICHAEL WARREN CITY OF WESTLAKE FOR NATURAL GAS DISTRIBUTION SYSTEM MAYOR: ROBERT BOB HARDY OPERATOR: MICHAEL WARREN Prepared by: Pipeline Integrity Partners, LLC January 2019 TABLE OF CONTENTS Emergency Plans (192.615)...

More information

Accident/Incident Reporting and Investigation Procedures

Accident/Incident Reporting and Investigation Procedures Accident/Incident Reporting and Investigation Procedures Policy reference Workplace Health and Safety Policy Procedure reference Workplace Health and Safety Risk Assessment Procedures Procedure It is imperative

More information

Technical Standards and Legislation: Risk Based Inspection. Presenter: Pierre Swart

Technical Standards and Legislation: Risk Based Inspection. Presenter: Pierre Swart Technical Standards and Legislation: Risk Based Inspection Presenter: Pierre Swart Agenda Change in Legislation. Where RBI fits in. Application to implement RBI. RBI concepts. Elements of an RBI analysis.

More information

Work Health & Safety Event Safety Checklist Small Event

Work Health & Safety Event Safety Checklist Small Event Note: This checklist relates to the Bedford Park site and contains information specific to that site. Other sites can use the checklist but may need to adapt the information. This documentation must be

More information

PLANT RISK ASSESSMENT REPORT

PLANT RISK ASSESSMENT REPORT PLANT RISK ASSESSMENT REPORT SECTION 1: PLANT IDENTIFICATION Report Number: 407/752 Assessment Date: 5 th May 2015 Company: Wacker Neuson Plant Type: Telescopic Light Balloon Make: Wacker Neuson Model:

More information

LEGIONELLA CONTROL POLICY

LEGIONELLA CONTROL POLICY LEGIONELLA CONTROL POLICY Originator: Policy and Strategy Team Approval date: August 2018 Review date: August 2019 1 Introduction 1.1 1.2 1.3 1.4 Pine Court Housing Association (PCHA) treats the health

More information

PLANT RISK ASSESSMENT REPORT

PLANT RISK ASSESSMENT REPORT PLANT RISK ASSESSMENT REPORT SECTION 1: PLANT IDENTIFICATION Report Number: 407/201-03 Assessment Date: 5 th June 2012 Company: Wacker Neuson Plant Type: Twin Drum Rollers Assessment Purpose: Operational

More information

EVENT SAFETY RISK ASSESSMENT - (SMALL TO MEDIUM SIZED COMMUNITY EVENTS) 1

EVENT SAFETY RISK ASSESSMENT - (SMALL TO MEDIUM SIZED COMMUNITY EVENTS) 1 EVENT SAFETY RISK ASSESSMENT (SMALL TO MEDIUM SIZED COMMUNITY EVENTS) EVENT SAFETY MANAGEMENT INFORMATION SHEET September 2010 #3 RISK ASSESSMENT IT S A MUST The success of your event is measured in many

More information

Maintaining electrical equipment/systems

Maintaining electrical equipment/systems Unit 037 Maintaining electrical equipment/systems Level: 2 Credit value: 15 NDAQ number: 500/9514/6 Unit aim This unit covers the skills and knowledge needed to prove the competences required to cover

More information

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply 4.1.1 General The primary function of a system for handling fuel oil is to transfer oil from the storage tank to the oil burner at specified conditions

More information

Risk Assessment & Safe Working Practice

Risk Assessment & Safe Working Practice RA Ref Number: 32 Revision: 4 Project/Job Number Reference Insert Job Number Approval Date: 30/03/2018 RA Description: confined space Next Review Date: 01/04/2019 Notes: Please refer to Safe Working Practices

More information

Installation Guide - C01202 & C01203 Thermostatic Mixing Valve TMV2

Installation Guide - C01202 & C01203 Thermostatic Mixing Valve TMV2 The following information is required for use when the Saracen range of thermostatic mixing valves is used in a TMV2 Applications under the requirements of BS EN 1111: 1999 Sanitary tap ware Thermostatic

More information

Appendix 1 Types and severity of conditions that could lead to site closure

Appendix 1 Types and severity of conditions that could lead to site closure ADVERSE CONDITIONS POLICY September 2010 CONTENTS 1 INTRODUCTION 2 PROCEDURE SITE REMAINS OPEN 3 PROCEDURE SITE IS CLOSED 4 COMMUNICATION 5 LATENESS OR ABSENCE 6 PAYMENT IN THE EVENT OF SITE CLOSURE 7

More information

OPERATING PROCEDURES

OPERATING PROCEDURES OPERATING PROCEDURES 1.0 Purpose This element identifies Petsec s Operating Procedures for its Safety and Environmental Management System (SEMS) Program; it applies to all Petsec operations. Petsec is

More information

Technical Documentation

Technical Documentation Recreational Craft Directive RYA Compliance Guide Appendix 7 Technical Documentation General The Technical Documentation is the key documentation required by the Directive. If challenged the builder must

More information

SEMEM3-65 Servicing anaesthetic and ventilation equipment

SEMEM3-65 Servicing anaesthetic and ventilation equipment Overview This unit identifies the competences you need to carry out servicing activities on anaesthetic and ventilation equipment, in accordance with approved procedures. You will be required to service

More information

SOP. Working in Confined Spaces

SOP. Working in Confined Spaces Purpose This procedure outlines the requirements for the management of entry into confined spaces in all work areas with the intention of minimising risks to health and safety from any potential hazards

More information

NATURAL GAS RESPONSE SOG

NATURAL GAS RESPONSE SOG SCOPE NATURAL GAS RESPONSE SOG This guideline shall apply to all members of the Stoney Point Fire Department and shall be adhered to by all members. PURPOSE The purpose of this guideline is to explain

More information

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION OCT2010 STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 020 87833050

More information

Reliability Assessment of the Whistler Propane Vaporizers

Reliability Assessment of the Whistler Propane Vaporizers Reliability Assessment of the Whistler Propane Vaporizers Prepared for: Terasen & Fransen Engineering Prepared by: ClearSky Risk Management Inc. 815 23 rd Ave East Vancouver, BC V6B 5Z3 Phone: 604.899.1470

More information