OPERATING INSTRUCTIONS FRIGOSTREAM GB

Size: px
Start display at page:

Download "OPERATING INSTRUCTIONS FRIGOSTREAM GB"

Transcription

1 OPERATING INSTRUCTIONS FRIGOSTREAM GB

2 Legal Notice Distribution, reproduction and translation of the software and its documentation (or excerpts thereof) are prohibited without the prior written consent of PHYSIOMED ELEKTROMEDIZIN AG. PHYSIOMED ELEKTROMEDIZIN AG reserves the right to change the software and associated data as well as the documentation without notice. All other rights reserved. PHYSIOMED ELEKTROMEDIZIN AG Hutweide 10 D Schnaittach/Laipersdorf (Germany) Phone: Fax: Internet: FRIGOSTREAM is produced in accordance with the quality requirements set forth in DIN EN ISO 13485:2003 and complies with current safety standards and regulations in accordance with the Medical Devices Act as set forth in Directive 93/42/EEC on Medical Devices dated 14 June The conformity with the specified directive is confirmed by the CE marking on the instrument. The declaration of conformity can be requested under the above mentioned address. Last updated February 16, 2010.

3 PHYSIOMED ELEKTROMEDIZIN AG Table of Contents Table of Contents Chapter 1 Introduction Conventions Used Instrument Symbols General Instructions Instrument Overview Instrument Description Application Rheumatology Surgery Neurology Sports Medicine Contraindications Chapter 2 Display and Control Elements Function of the Display and Control Elements Display <1> Mode Key <2> Start/Stop Key <3> Plus/Minus Keys <4> Power Switch Chapter 3 Operation of the Instrument Start-up of the Instrument Functional Test Instrument Errors Defrosting the Instrument Chapter 4 Treatment Appendix A Appendix A.1 Customer Service, Maintenance, Service A.2 Cleaning and Disinfecting Agent A.3 Transport FRIGOSTREAM i

4 Table of Contents PHYSIOMED ELEKTROMEDIZIN AG A.4 Service Life and Disposal A.5 Electromagnetic Compatibility A.6 Technical Data A.7 Manufacturer Information Appendix B Scope of Delivery and Accessories B.1 Scope of Delivery B.2 Available Accessories Appendix C Supplementary Documents C.1 Manufacturer s Recommendation Index ii FRIGOSTREAM

5 PHYSIOMED ELEKTROMEDIZIN AG 1 Introduction Chapter 1 Introduction By purchasing FRIGOSTREAM you have acquired an extremely versatile, advanced cryotherapeutic instrument. However, it can be utilized optimally only once you are informed about the function of the control elements. Therefore, read the given instruction manual carefully and make yourself thoroughly familiar with the instrument before its use. 1.1 Conventions Used Please note the following typographical conventions in these Operating Instructions: Cross references and important terms used for the first time in this document are written in italics. Names of menus and symbols on the display are written in bold typeface. Paragraphs that deserve special attention are highlighted in the following way: Symbol Type Meaning Tip Note Important Caution Intended to give you some extra hints for more convenient operation Provides background information for better understanding Prevents misunderstandings that might lead to limited operation of the instrument or insufficient therapeutical results Alerts you in cases of possible damage to the instrument or risks of injury 1.2 Instrument Symbols The symbols affixed to the instrument have the following meaning: Symbol Meaning Make sure that the instrument is disposed of in an environmentally sound manner! It is absolutely necessary to separate old instruments from household waste (see Service Life and Disposal on page 14) before disposal once their lifetime has expired! 1.3 General Instructions FRIGOSTREAM may be used only in dry rooms suitable for medical purposes as set forth in DIN VDE , Application Group 1. These are rooms with beds, physiotherapy rooms, massage rooms and practitioner s rooms. The instrument complies with the technical requirement of VDE 0750/IEC 60601, classification in accordance with EU Directive on Medical Devices (93/42/EEC): Class IIa. FRIGOSTREAM 1

6 1 Introduction PHYSIOMED ELEKTROMEDIZIN AG Caution The instrument may be operated only and exclusively by medically qualified personnel after appropriate instruction! Kindly ensure proper usage of the instrument in accordance with the instruction manual! The instrument is unsuitable for use in explosive areas and hydrotherapy rooms. A drastic change in temperature must be avoided owing to possible bedewing of the instrument; it must be put into operation only after a temperature equalisation! The operation of the instrument in the proximity of (e.g. at a distance of 1 m from) a shortwave or microwave therapeutic instrument can lead to fluctuations in the original values of the instrument and must, therefore, be absolutely avoided! 1.4 Instrument Overview Control Panel Instrument View Legend 1 Display 2 Mode Key 3 Start/Stop Key 4 Plus/Minus Keys 2 FRIGOSTREAM

7 PHYSIOMED ELEKTROMEDIZIN AG 1 Introduction 1.5 Instrument Description FRIGOSTREAM is a cryotherapeutic instrument, which has been applied successfully in different medical fields. It is primarily foreseen as a therapeutic instrument for application in a clinical and therapeutic environment. The cooling circuit of the FRIGOSTREAM is a closed circuit. The instrument has been filled with a predefined volume of protective cooling medium and is hermetically sealed. The instrument complies with all the applicable safety standards, in particular: IEC : Electronic Medical Devices, Part 1: General Safety Requirements 1.6 Application Cryotherapy is used in different medical fields. These fields include: rheumatology orthopaedics surgery sports medicine neurology internal medicine The treatment of these indications takes place through the application of different cooling media. These are: ice chips compresses ice packs mudpacks cooling spray nitrogen cooling air Rheumatology Applications of cryotherapy within rheumatology in connection with massages and kinesitherapy: In the case of inflammatory diseases: arthritides spondylitides bursitides gout rheumatoid arthritis in acute episode In the case of non-inflammatory diseases: arthroses acute arthrosis humeroscapularis FRIGOSTREAM 3

8 1 Introduction PHYSIOMED ELEKTROMEDIZIN AG acute epicondylitis myalgias lumbar ischialgias dorsalgias sacralgias acute lumbago acute cervical syndrome Surgery Applications of cryotherapy within accident surgery, orthopaedics, mouth and jaw surgery: prophylaxis of swellings in the case of fresh fractures and in the post-operative phase sprains crushing injuries contusions pulled muscles luxations (all kinds of injuries to the ligament and joint system) Sudeck's syndrome lymphedema after amputation of the breast prevention of reactive effusions acute inflammations Neurology Applications of cryotherapy within neurology: spastic hemipareses and parapareses neuralgias (e.g. migraine, trigeminus neuralgia) multiple sclerosis post-apoplectical conditions acute neuritis Sports Medicine Applications of cryotherapy within sports medicine: fresh sports injuries soft tissue injuries injuries to the ligament and joint system (e.g. muscle contusions, traumatic bursitis, humeral epicondylitis, cervical spine whiplash injury) 1.7 Contraindications May not be treated with FRIGOSTREAM in the case of: arterial occlusive diseases (especially Fontaine stages III and IV) grave functional blood circulatory disorders common cryoglobulinaemia 4 FRIGOSTREAM

9 PHYSIOMED ELEKTROMEDIZIN AG 1 Introduction cold urticaria trophic disturbances and tissue lesions Raynaud s symptomatology pregnancy (a treatment during pregnancy may be performed only in consultation with the attending doctor!) FRIGOSTREAM 5

10 2 Display and Control Elements PHYSIOMED ELEKTROMEDIZIN AG Chapter 2 Display and Control Elements The FRIGOSTREAM is designed in such a way that it is very easy to operate in spite of manifold functions. All the display and control elements are integrated in the housing in order that the surface can be cleaned easily and the instrument is free from dust. The micro-processor of the instrument monitors the safety-relevant components, prevents maloperation and tests the instrument every time it is switched on. 2.1 Function of the Display and Control Elements The individual display and control elements of the FRIGOSTREAM have been presented in the following sections. The numbers in angle brackets refer to the Instrument Overview on page Display <1> In the Display <1> the selectable therapy parameters are displayed depending upon the current context. Display <1> Mode Key <2> The Mode Key <2> above the Display <1> serves the purpose of selecting the programmes Flow, Time or Defrost. Mode Key <2> 6 FRIGOSTREAM

11 PHYSIOMED ELEKTROMEDIZIN AG 2 Display and Control Elements Start/Stop Key <3> The Start/Stop Key <3> above the Display <1> serves the purpose of starting and ending the therapy in the individual menus. Start/Stop Key <3> Plus/Minus Keys <4> The Plus/Minus Keys <4> below the Display <1> serve the purpose of setting the parameters in the individual menus. Plus und Minus Keys <4> Power Switch The Power Switch is on the rear side of the instrument. With the Power Switch, the mains voltage of the FRIGOSTREAM is switched on and/or off. FRIGOSTREAM 7

12 3 Operation of the Instrument PHYSIOMED ELEKTROMEDIZIN AG Chapter 3 Operation of the Instrument Caution The filter attached to the rear side of the instrument must be cleaned and/or washed every week! Note Optimal operating conditions are given if used in air-conditioned rooms and at a humidity of maximum 50-60%. In the worst case, there can be water formation in connection with a defrosting process if there is very high humidity and high outside temperatures. Important Increased humidity and temperatures above 30 C may impact the cooling performance of the instrument. The average permanent operating time may decrease with rising temperature and humidity. We recommend using FRIGOSTREAM only in air-conditioned rooms. 3.1 Start-up of the Instrument Before you can perform the first treatment with the FRIGOSTREAM, you must first start up the instrument properly. Since the instrument is mounted on rollers ex-factory, it may be operated only on level surfaces. Caution While setting up the FRIGOSTREAM, a distance of approx. 10 cm must be observed between the instrument and the wall, since it can otherwise result in loss of performance. The lateral distance from the walls must be minimum 20 cm. Instruments with strong electromagnetic fields (X-ray and/or diathermic apparatuses) can influence the functioning of the instrument. How to Start up the Instrument (1) Make sure that the instrument is switched off (the Power Switch is on Position 0). (2) Plug the power cord on the rear side of the instrument tightly into the power socket. A safe connection can be established via a shockproof socket with protective earthing conductor. (3) Actuate the Power Switch on the rear side of the instrument. (4) The instrument cools down to the point where the operating temperature is achieved. The message Loading flashes on the display and the status of the cooling process is displayed by means of a progress bar. 8 FRIGOSTREAM

13 PHYSIOMED ELEKTROMEDIZIN AG 3 Operation of the Instrument Progress Display of the Cooling Process At the end of the cooling phase, the instrument automatically changes over to the menu Flow and is then ready for operation. For longer treatments, it is urgently recommended to allow the instrument to cool down for another minutes. The further progress of the cooling is no longer visible in the display during this time span. 3.2 Functional Test If you are not sure as to whether your FRIGOSTREAM is working properly, you can conduct a self-test. How to Execute a Functional Test (1) Switch off the instrument by means of the Power Switch and then switch it on again. The instrument will conduct an automatic functional test whereby all the functions and original values will be checked. The instrument is now ready to operate. You are in the Flow menu. 3.3 Instrument Errors In case a malfunction is ascertained during the self-test or during operation, the Display <1> shows the message ERROR LOAD. In case the message was caused by a temporary disturbance and disappears after a brief period, the instrument is immediately ready to operate once again without switching off and on. However, if the error continues, the message once again appears. In this case, switch the instrument on and off several times. In doing so, the instrument will conduct a self-test (see Functional Test on page 9). Ascertain afterwards as to whether the message is still being displayed. Important Notify your service partner in case the error recurs even after several self-tests! Under no circumstances is it allowed to carry out any treatment unless the functional fitness of the instrument is ensured! FRIGOSTREAM 9

14 3 Operation of the Instrument PHYSIOMED ELEKTROMEDIZIN AG 3.4 Defrosting the Instrument In case there is a perceptible decrease in air flow rate or small ice particles are blown out (as a rule, only after approx. 4 hours of continuous operation) you ought to defrost the instrument in order that the full air flow rate can be guaranteed. How to Defrost the Instrument (1) Press the Mode key twice in order to reach the Defrost menu. Defrost Menu (2) Press the Start/Stop key for approx. 5 seconds. The defrosting process starts. The message Run flashes on the bottom right of the display. In addition, the current storage temperature is displayed. The defrosting process is running (3) The defrosting process runs until a storage temperature of +10 C is achieved. Thereafter, the FRIGOSTREAM once again cools down automatically to the operating temperature. 10 FRIGOSTREAM

15 PHYSIOMED ELEKTROMEDIZIN AG 4 Treatment Chapter 4 Treatment The FRIGOSTREAM knows the following menus and operating conditions: Flow: Adjust the blower position and perform the treatment Time: Adjust the treatment time Defrost: Defrost the instrument How to Perform a Treatment (1) Make sure that the instrument is ready to operate (see Start-up of the Instrument on page 8). You are in the Flow menu. (2) Press the Start/Stop key for starting the treatment. The message Run flashes on the bottom left of the display. (3) Set the desired blower position by means of the Plus and Minus keys (nine positions). On the Display <1> the set blower position is displayed: Flow Menu (4) Once again press the Start/Stop key, if you wish to end the treatment. Note You can also limit the treatment to a specific period by setting a treatment time (see How to Set the Treatment Time on page 11). Once the treatment time is over, the blower switches off. How to Set the Treatment Time (1) Press the Mode key, in order to reach the Time menu. Time Menu FRIGOSTREAM 11

16 4 Treatment PHYSIOMED ELEKTROMEDIZIN AG (2) Set the desired treatment time by means of the Plus and Minus keys. On the Display <1> the set set treatment time is displayed. Continuous treatment with adjusted therapy time Note You can interrupt the treatment at any time by pressing the Start/Stop key. In the Time menu, If you do not change the treatment time, the instrument automatically changes over to the Flow menu after a few seconds. 12 FRIGOSTREAM

17 PHYSIOMED ELEKTROMEDIZIN AG Appendix Appendix A Appendix Cooling Medium The cooling circuit of the cryotherapeutic instrument FRIGOSTREAM is a closed system. The instrument has been filled with a predefined volume of protective cooling medium and is hermetically sealed. Thus, no maintenance of the cooling circuit is required. A.1 Customer Service, Maintenance, Service The manufacturer is responsible only for the original security relevant properties of the instrument. The instrument must be used generally in conformance with the user manual. Maintenance measures on the instrument may be carried out only at the PHYSIOMED ELEKTROMEDIZIN AG authorised locations. If the work is carried out by such locations, a certification should be obtained from them about the type and extent of the work. possibly with information relating to the modifications in the rated data or the work range. The certification must also contain the date of execution as well as company name and signature. Failed components, which influence the safety of the instrument, must be replaced with original parts. Circuit diagrams, parts lists and service instructions shall be made available to qualified technical personnel of the user on request. We recommend carrying out regular servicing of the instrument and accessories. The defined safety-relevant inspections are given in our manufacturer's recommendations (see Manufacturer s Recommendation on page 17). A.2 Cleaning and Disinfecting Agent Clean the instrument and accessories regularly with customary chlorine-free and bleach-free cleaning agents (e.g. a disinfecting agent based on aldehyde). In doing so, make absolutely sure the instrument is previously switched off! Clean the instrument with a soft cloth. Make sure that no liquid penetrates into the instrument during the cleaning! We recommend that you clean the hand-piece of the tube likewise with a customary disinfecting agent, e.g. Dismozon pur. Caution If set up in extremely dirty rooms, the condensers and cooling units must be cleaned of dust and dirt approx. every 6 months! Caution The filter attached to the rear side of the instrument must be cleaned and/or washed every week! FRIGOSTREAM 13

18 Appendix PHYSIOMED ELEKTROMEDIZIN AG A.3 Transport In order to avoid all kinds of transportation losses, the shipment of a FRIGOSTREAM must always be undertaken in the original packing envisaged for it. The instrument must not be transported in recumbent position. However, if this should be the case, the instrument ought not to be started up for another half an hour. A.4 Service Life and Disposal Due to legislation, the service life of this medical product has a limit of sieben years. The instrument has to be disposed in compliance with the legal obligations. Therefore, pay attention to the applicable regulations for environment protection. Please contribute to environment protection by not putting used instruments into your domestic waste. A.5 Electromagnetic Compatibility Declaration in accordance with Standard EN : Electromagnetic Compatibility Electronic medical instruments are subject to special precautionary measures in respect of electromagnetic compatibility. Portable and mobile HF communication instruments can influence electronic medical instruments. 14 FRIGOSTREAM

19 PHYSIOMED ELEKTROMEDIZIN AG Appendix A.6 Technical Data Protection Class VDE 0750 / IEC CE Marking Class in accordance with Directive on Medical Devices (93/42/EEC) Mains Supply Mains Frequency Mains Fuse Power Consumption Air Flow Rate Power Drain Length of Treatment Tube Optimum Operating Temperature Admissible Operating Temperature 1, Type B in accordance with Directive 93/42/EEC on Medical Devices IIa V or V 50 / 60 Hz 2 x T16 A at V or 2 x T15 A at V 1,800 VA 1,500 l/min 9 Positions 170 cm C C Maximum Humidity 65% Dimensions (W x H x D) Weight 36.0 x 93.0 x 48.0 cm 53 kg A.7 Manufacturer Information Manufacturer mecotec GmbH Mannheimer Straße 14 D Pforzheim (Germany) For queries, kindly contact the distributor: PHYSIOMED ELEKTROMEDIZIN AG Hutweide 10 D Schnaittach/Laipersdorf (Germany) FRIGOSTREAM 15

20 Scope of Delivery and Accessories PHYSIOMED ELEKTROMEDIZIN AG Appendix B Scope of Delivery and Accessories Important For safety reasons, the instrument is to be used exclusively with original accessories. The use of other manufacturers' accessories is at the user's risk! B.1 Scope of Delivery FRIGOSTREAM is be delivered with the following accessories: Item No. Identification Quantity Cryotherapy instrument FRIGOSTREAM Nozzle attachment 5 mm Nozzle attachment 10 mm Nozzle attachment 15 mm Slotted nozzle Tube Operating Instructions (English) 1 B.2 Available Accessories For FRIGOSTREAM the following accessories are included in the delivery: Item No. Identification Nozzle attachment 5 mm Nozzle attachment 10 mm Nozzle attachment 15 mm Slotted nozzle Supporting arm FRIGOSTREAM incl. fixation (laser version) Tube Tube laser version 16 FRIGOSTREAM

21 PHYSIOMED ELEKTROMEDIZIN AG Supplementary Documents Appendix C Supplementary Documents C.1 Manufacturer s Recommendation FRIGOSTREAM 17

22 Index PHYSIOMED ELEKTROMEDIZIN AG Index A accessories 16 included 16 ambient temperature 15 application 3 arterial occlusions arterial 4 arthritides 3 arthritis rheumatoid 3 arthroses 3 arthrosis humeroscapularis ccute 3 available accessories 16 B bursitides 3 C CE marking 15 cervical syndrome acute 3 circulatory disorders functional 4 cleaning 13 cold urticaria 4 contraindications 4 control elements function 6 control elements 6 contusions 4 cooling 8 crushing injuries 4 cryoglobulinaemia 4 customer service 13 D Defrost 10 defrosting 10 dimensions 15 disinfecting agent 13 Display 6 display elements 6 function 6 disposal 14 disturbances trophic 4 dorsalgias 3 E electromagnetic compatibility 14 EMV 14 epicondylitis acute 3 error Codes 9 F functional test 9 functions 3 G gout 3 H hemipareses 4 I indications neurology 4 rheumatology 3 sports medicine 4 surgery 4 inflammations acute 4 instructions general 1 instrument description 3 instrument errors 9 instrument overview 2 instrument symbols 1 L load impedance 15 lumbago acute 3 lumbar ischialgias 3 luxations 4 lymphedema 4 M maintenance 13 manufacturer s recommendation 17 medical fields 3 mode key 6 modulation 15 multiple sclerosis 4 myalgias 3 18 FRIGOSTREAM

23 PHYSIOMED ELEKTROMEDIZIN AG Index N neuritis acute 4 neurology 4 O operating conditions 11 operation 8 original packing 14 output frequency 15 output voltage 15 P parapareses 4, 4 plus/minus keys 7 power switch 7 pregnancy 4 protection class 15 pulled muscles 4 R Raynaud s symptomatology 4 reactive effusions 4 S sacralgias 3 service 13 service life 14 soft tissue injuries 4 spondylitides 3 sports injuries 4 sports medicine 4 sprains 4 start-up 8 start/stop key 7 storage temperature 10 Sudeck s syndrome 4 surgery 4 T technical data 15 tissue lesions 4 transport 14 treatment 11 W wave form 15 weight 15 FRIGOSTREAM 19

OPERATING INSTRUCTIONS PSORIAMED. Revision: 1.0-D GB

OPERATING INSTRUCTIONS PSORIAMED. Revision: 1.0-D GB OPERATING INSTRUCTIONS PSORIAMED Revision: 1.0-D 01501 GB Legal Notice Distribution, reproduction and translation of the software and its documentation (or excerpts thereof) are prohibited without the

More information

User Manual PTW-DensiX. D / Di/Zi

User Manual PTW-DensiX. D / Di/Zi User Manual PTW-DensiX D148.131.0/3 2005-05 Di/Zi General Information General Information The product bears the CE-mark "CE-0124" in accordance with the Council Directive 93/42/EEC about Medical Devices

More information

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques.

More information

KERN EG/EW Version /02

KERN EG/EW Version /02 E KERN EG/EW Version 1.5 07/02 Operating Instructions Electronic Precision Balances Contents 1 TECHNICAL DATA... 20 2 UNPACKING AND STANDARD ACCESSORIES... 23 3 SETTING UP THE BALANCE... 23 4 EXTERNAL

More information

F-330 Instruction manual. Magic Glove Bio Skin Smoother High Frequency Ultrasound Galvanic

F-330 Instruction manual. Magic Glove Bio Skin Smoother High Frequency Ultrasound Galvanic F-330 Instruction manual Magic Glove Bio Skin Smoother High Frequency Ultrasound Galvanic Warning Never under any circumstances attempt to open or inspect the internal components or accessories of the

More information

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev. 3G Operating instructions Type: 03-5110-00.. Document no.: 03-5110-7D0001 Version: 01. July 2011/Rev. 0 Operating Instructions Type: 03-5110-00.. Document no.: 03-5110-7D0001 Version: 1 July 2011 / Rev.

More information

Operating Instructions. ATMOS Chair Comfort. English GA1GB Index 01

Operating Instructions. ATMOS Chair Comfort. English GA1GB Index 01 Operating Instructions ATMOS Chair Comfort English GAGB.3020.0 208- Index 0 Table of contents Introduction...3. Notices on the operating instructions...3.2 Explanation of pictures and symbols...4.3 Intended

More information

Instruction Manual BA90 Precision Barometer

Instruction Manual BA90 Precision Barometer Instruction Manual BA90 Precision Barometer halstrup-walcher GmbH Stegener Straße 10 D-79199 Kirchzarten Germany Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-Mail: info@halstrup-walcher.com

More information

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions VS18/26 with PROFINET and EtherNet/IP Interface ATEX Installation Instructions INDEX 1. INTENDED USAGE 3 2. OPERATING MANUAL ATEX 4 2.1 General conditions 4 2.2 Installation 5 2.3 Operating 5 2.4 Failures

More information

User manual. MNPG 102 Rev. 04 Edition 04/02/16. Pressotherapy model. Power-Q1000 Premium

User manual. MNPG 102 Rev. 04 Edition 04/02/16. Pressotherapy model. Power-Q1000 Premium User manual MNPG 102 Rev. 04 Edition 04/02/16 Pressotherapy model Power-Q1000 Premium I.A.C.E.R. Srl Via S. Pertini 24/A 30030 Martellago (VE) ITALY Tel. 041.5401356 Fax 041.5402684 e-mail: iacer@iacer.it

More information

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100 MPS-1100 User Manual Mega Pool Saver Ltd PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100 For further up to date instructions on how to install Mega Pool Saver MPS 1100, please

More information

Med Aire Alternating Pressure Pump and Pad System

Med Aire Alternating Pressure Pump and Pad System User Manual Med Aire Alternating Pressure Pump and Pad System 14002E 14001E Symbols & Statements NOTE Indicates some tips or some information users should be aware of. CAUTION Indicates correct operating

More information

CJMJ.DPNQBDU. Instruction for use. Neonatal phototherapy device. BILI-COMPACT WY 1816/ Year of manufacture D2017_00

CJMJ.DPNQBDU. Instruction for use. Neonatal phototherapy device. BILI-COMPACT WY 1816/ Year of manufacture D2017_00 Instruction for use Neonatal phototherapy device CJMJ.DPNQBDU D2017_00 GmbH > BILI-COMPACT WY 1816/ Year of manufacture Herrenhöhe 4 D-51515 Kürten/Germany 02207-9698-0 02207-4750 E-mail: info@weyermed.com

More information

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Type 0404 / 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions

More information

User manual. PG132 Rev01 Editi Compressive Limbs Therapy System DVT-7700

User manual. PG132 Rev01 Editi Compressive Limbs Therapy System DVT-7700 User manual PG132 Rev01 Editi 220114 Compressive Limbs Therapy System DVT-7700 I.A.C.E.R. Srl Via S. Pertini 24/A 30030 Martellago (VE) ITALY Tel. 041.5401356 Fax 041.5402684 e-mail: iacer@iacer.it http://www.itechmedicaldivision.com

More information

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar EN - english Instructions for installation and operation Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar Dear customer, Thank you for deciding in favour of the METPOINT

More information

User manual. PG89 Rev 01 Editi Pressotherapy model. LymphoPress 4

User manual. PG89 Rev 01 Editi Pressotherapy model. LymphoPress 4 User manual PG89 Rev 01 Editi 040515 Pressotherapy model LymphoPress 4 I.A.C.E.R. Srl Via S. Pertini 24/A 30030 Martellago (VE) ITALY Tel. 041.5401356 Fax 041.5402684 e-mail: iacer@iacer.it http://www.itechmedicaldivision.com

More information

Operating Manual Body fat balance

Operating Manual Body fat balance KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating Manual Body fat balance KERN MFB Version

More information

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners 7 634 VGS1... with AGA67 connector VGS2... with AGA67 connector Solenoid gas valve VGS The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners The VGS and

More information

Instrument Description and Operating Instructions OXYMAT 2. Its own oxygen source

Instrument Description and Operating Instructions OXYMAT 2. Its own oxygen source Instrument Description and Operating Instructions OXYMAT 2 Its own oxygen source OXYMAT 2 Fig. 1 5 6 1 15 2 3 4 8 15 7 9 12 10 13 11 14 Legends 1 OXYMAT 2 oxygen concentrator 2 Oxygen outlet 3 Main switch

More information

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator Self-operated Pressure Regulators Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Type 2357-31 with non-return unit at port C Ports A and B with soldering

More information

Norrsken Family Booklet

Norrsken Family Booklet Section 1: Introduction Low Energy Designs produce efficient and effective LED based lighting products for commercial, retail and industry purposes. Each product may contain specific details on its operation

More information

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14 15 Elster GmbH Edition 7.15 Translation from the German 519 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve for gas VG VG 15/1 Contents Solenoid valve for gas

More information

Operating Instructions Temperature Measuring System MF420-5T-100

Operating Instructions Temperature Measuring System MF420-5T-100 Operating Instructions Temperature Measuring System Dnhqdhnjah MF420-5T-100 Dmsklakla Read before use! Observe all safety instructions! Keep for future reference! Fon +49/7221/64103 Fax +49/7221/17103

More information

User Manual. Quantos Automated Dosing Liquid Module

User Manual. Quantos Automated Dosing Liquid Module User Manual Liquid Module 1 Safety Information 1.1 Definition of warnings and symbols Signal Words WARNING for a hazardous situation with medium risk, possibly resulting in severe injuries or death if

More information

OptonPro. High-power laser up to 7000 mw. Laser therapy natural healing with the power of light

OptonPro. High-power laser up to 7000 mw. Laser therapy natural healing with the power of light GB High-power laser up to 7000 mw Laser therapy natural healing with the power of light Application of high-power light for targeted penetration of high amounts of energy deep into the tissue. Initiates

More information

Pressure Automated Calibration Equipment

Pressure Automated Calibration Equipment GE Measurement & control Pressure Automated Calibration Equipment Safety Instructions and User Guide - K0447 PACE5000 PACE6000 K0447 Issue No. 9 1 10 1 PACE5000 1 2 3 4 5 PACE6000 2 6 7 8 3 4 5 6 7 8 9

More information

MAGNETRON 40HS / 40DC / 40TC [Clarification- HS =home system/ DC= doctors Clinic / TC= Therapy Center]

MAGNETRON 40HS / 40DC / 40TC [Clarification- HS =home system/ DC= doctors Clinic / TC= Therapy Center] USER HAND BOOK MAGNETRON-40HS / 40DC / 40TC Pragati Micro Instruments P Ltd Hyderabad Page 1 SAFETY WARNING The voltages employed in this Equipment are sufficiently high to endanger human life. POWER MUST

More information

POWERPRESS UNIT. User Manual. Gradient Pneumatic Sequential Compressor. Neomedic

POWERPRESS UNIT. User Manual. Gradient Pneumatic Sequential Compressor. Neomedic TIMER (MIN) POWERPRESS UNIT 40 70 40 80 90 10 60 100 MIN MAX PRESSURE (mmhg) User Manual Neomedic 9601 Owens mouth Ave. #8 Chatsworth, CA 91311 Toll Free: 866-990-1168 Tel: 818-998-1023 Fax: 818-998-0277

More information

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1* Safety Manual Process pressure transmitter IPT-1* 4 20 ma/hart Process pressure transmitter IPT-1* Contents Contents 1 Functional safety 1.1 General information... 3 1.2 Planning... 4 1.3 Instrument parameter

More information

Instruction Manual for Configura Cushionair Portable Pump

Instruction Manual for Configura Cushionair Portable Pump Instruction Manual for Configura Cushionair Portable Pump Fitted with battery powered pump, suitable for Configura Portable chairs V E R S I O N O N E M A Y 2 0 1 6 Contents Introduction 3 Set up of Cushionair

More information

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL

MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL English MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL CONFETTI FX / STREAMER FX Manual trigger PART01129 rev 01-00 DISCLAIMER WARNING Read this manual carefully before installing and/or using this

More information

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22. *09005087* DB_BA_EN_ME01_S Rev.A 12/16 *09005087* d e v e l o p i n g s o l u t i o n s Data Sheet and Operating Manual ME01 Digital manometer Table of Contents ME01 ## # 87 # HL S#### Dust explosion protection

More information

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual Sensor for Air Bubble Detection at Liquid Filled Tubes SONOCHECK Type ABD06.xx Operating Manual Manufacturer: Model: Type: SONOTEC Ultraschallsensorik Halle GmbH Air Bubble Detector ABD06.xx SONOTEC Ultraschallsensorik

More information

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor halstrup-walcher GmbH Stegener Straße 10 D-79199 Kirchzarten Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-Mail: info@halstrup-walcher.com

More information

Instruction Manual. Pressure Vessels

Instruction Manual. Pressure Vessels Instruction Manual Pressure Vessels acc. to DGRL 97 / 23 / EG Edition December 2006 INSTRUCTION MANUAL FOR PRESSURE VESSELS ACCORDING TO DGRL 97/23/EG Production year: * Pressure vessel production number:

More information

1 METRON MANIPULATION TABLES - WARRANTY STATEMENT

1 METRON MANIPULATION TABLES - WARRANTY STATEMENT 1 METRON MANIPULATION TABLES - WARRANTY STATEMENT Metron Medical Australia Pty Ltd. will warrant this table, for parts only against defects in manufacture for a period of two (2) years for structural integrity,

More information

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV VENTIlogic LS VENTIlogic plus 100 % Mobility and Reliability in IV and NIV VENTIlogic LS VENTIlogic plus Your requirements for reliability and mobility are our benchmark. VENTIlogic LS and VENTIlogic plus

More information

STAGE, STADIUM & X-TREME SHOT.

STAGE, STADIUM & X-TREME SHOT. USER AND INSTALLATION MANUAL ENGLISH STAGE, STADIUM & X-TREME SHOT. CONFETTI & STREAMER FX PART01339 rev 01-00 DISCLAIMER WARNING Read this manual carefully before installing and/or using this product.

More information

OPERATION INSTRUCTIONS

OPERATION INSTRUCTIONS ULTRASONIC SCALER OPERATION INSTRUCTIONS Rev.05/2011 TM ULTRASONIC SCALER OPERATION INSTRUCTIONS Guilin Veirun Medical Technology Co., Ltd. Building B, Information Industrial Park D-07, National High-Tech

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

Instruction Manual Contact Pressure Vacuum Gauge

Instruction Manual Contact Pressure Vacuum Gauge MS10 Instruction Manual Contact Pressure Vacuum Gauge Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information

Siphon vessel / Priming aid

Siphon vessel / Priming aid Manufacturer: sera GmbH sera-straße 1 34376 Immenhausen Germany Tel.: +49 5673 999-00 Fax: +49 5673 999-01 info@sera-web.com Keep the operating manual for future use! Record the exact type and serial number

More information

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation 2/2- and 3/2-way cartridge solenoid valve 2/2- und 3/2-Wege-Cartridge-Magnetventil Électrovanne cartridge à 2/2 ou 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the

More information

Pressure maintenance valve SDV-P / SDV-P-E

Pressure maintenance valve SDV-P / SDV-P-E Translation of the original manual Pressure maintenance valve SDV-P / SDV-P-E Assembly and Operating Manual Superior Clamping and Gripping Imprint Imprint Copyright: This manual remains the copyrighted

More information

Customer Responsibilities

Customer Responsibilities Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

Manual. Kingpad mc-32 Edition. Bus system control pad for installation in the Graupner mc-32 transmitter. No Copyright Graupner/SJ GmbH

Manual. Kingpad mc-32 Edition. Bus system control pad for installation in the Graupner mc-32 transmitter. No Copyright Graupner/SJ GmbH EN Manual Kingpad mc-32 Edition Bus system control pad for installation in the Graupner mc-32 transmitter No. 3974.32 Copyright Graupner/SJ GmbH 2 / 16 Index Introduction... 5 Service Centre... 5 Intended

More information

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0 Operating Manual LTIA5E Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0 Contents 1. Safety Instructions 2. Conformity to standards 3. Technical data

More information

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity Type 4708-45 Supply Pressure Regulator with increased air capacity Translation of original instructions Mounting and Operating Instructions EB 8546-1 EN Edition March 2016 Note on these mounting and operating

More information

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument OxyScan Graphic Operating Instructions UMS Micro-oxygen sensor 501 Microprocessor instrument Introduction Thank you for choosing the UMS Micro Oxygen Sensor 501 - a highly advanced product! Please read

More information

PRAHER PLC-MP AQUASTAR MANAUL 2009

PRAHER PLC-MP AQUASTAR MANAUL 2009 PRAHER PLC-MP AQUASTAR MANAUL 2009 1. Copyrights This Operating Manual contains copyright-protected information. All rights reserved to Praher Kunststofftechnik GmbH. This Operating Manual is designed

More information

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520 Operating instructions Contents EN Pressure switch, heavy-duty version Model PSM-520 1. General information 2. Design and function 3. Safety 4. Transport, packaging and storage 5. Commissioning, operation

More information

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS VERTICAL AIR COMPRESSORS MODEL NO: VE15C150, VE18C150, VE25C150 PART NO: 2226010, 2226020, 2226025 OPERATION & MAINTENANCE INSTRUCTIONS LS0715 INTRODUCTION Thank you for purchasing this CLARKE Vertical

More information

Instruction Manual Otoflash G171 UV-flash-device for Light Curing

Instruction Manual Otoflash G171 UV-flash-device for Light Curing Instruction Manual Otoflash G171 UV-flash-device for Light Curing Index 1) General Information 2) Initial Operation of Device 3) Important Notes 4) Use with timer 5) Exchanging the flash module 6) Maintenance,

More information

Digital Melting Point Apparatus

Digital Melting Point Apparatus Digital Melting Point Apparatus Heating Plateau Ramping Start/Stop Plateau set Ramp stop Hold User Guide Version 1.1 Heating Viewing tube Sample Chamber IEC power inlet socket Power on/off Temperature

More information

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar Instruction manual for high purity gas pigtails 200 bar / 300 bar Contents Contents... 2 1. Preface... 3 1.1 Overview... 3 1.2 General... 3 1.3 Intended use... 4 1.4 Personnel requirements... 4 2. For

More information

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027 Operating Instructions Ball valve fitting according to ZB 2553 For pressure transmitter VEGABAR 82 Document ID: 50027 Contents Contents 1 About this document 1.1 Function... 3 1.2 Target group... 3 1.3

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125

TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125 TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125 Model: VC-40-VYC Table of contents 1. - Installing the test bench 1.1.1- Connecting the compressed air / nitrogen source 1.1.2- Maximum test pressure according

More information

Model : LMW-9620 Please read this manual carefully before using the instrument Labnics Equipment

Model : LMW-9620 Please read this manual carefully before using the instrument Labnics Equipment MICROPLATE WASHER User Manual Model : LMW-9620 Please read this manual carefully before using the instrument Labnics Equipment Table of Content Sr.No. Contents Pg. No. 1 INTRODUCTION 1 1.1 Working Conditions

More information

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies Type 2000 INOX 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies Quickstart English Deutsch Français Contents 1 QUICKSTART... 2 2 CONTACT ADDRESS... 2 3 INTENDED USE...

More information

Please read these instructions carefully before use! Please consider the safety instructions! Please keep for future reference!

Please read these instructions carefully before use! Please consider the safety instructions! Please keep for future reference! Z11.0.1X.6C-18 Mounting and Operating Manual Atmospheric Oxygen Sensor Element GOEL 370, GOEL 381 Please read these instructions carefully before use! Please consider the safety instructions! Please keep

More information

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV VENTIlogic LS VENTIlogic plus 100 % Mobility and Reliability in IV and NIV VENTIlogic VENTIlog LS Your Requirements for Reliability and Mobility are Our Benchmark. VENTIlogic LS and VENTIlogic plus are

More information

idromed 4 GS OPERATING INSTRUCTIONS Art.-No

idromed 4 GS OPERATING INSTRUCTIONS Art.-No Art.-No. 19160 Before putting the unit into operation and starting the treatment, read these operating instructions carefully. #19160 / S1205 e EU 230 V / 50 Hz Dear Sir or Madam, With the you have purchased

More information

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0 Operating Manual LTIA3E Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0 Contents 1. Safety Instructions 2. Conformity to standards 3. Technical

More information

Customer Responsibilities

Customer Responsibilities Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on)

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on) by Supera Anesthesia Innovations USER'S GUIDE OC4000 OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY I O : ON (power switched on) : OFF (power switched off) : Class II protection : Do not expose to open flames

More information

User Manual soft air wds

User Manual soft air wds User Manual soft air wds Item. No. 110 400-wds soft air cumulus wds Item. No. 110 400-cu-wds Pressure ulcer prevention and treatment-systems Assembly and Operation instructions Health. Safety. Independence.

More information

Customer Responsibilities

Customer Responsibilities Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

VENTI-O 2 plus. O 2 switching valve for: VENTImotion from serial number 4000 VENTIlogic from serial number 4000 VENTImotion 2

VENTI-O 2 plus. O 2 switching valve for: VENTImotion from serial number 4000 VENTIlogic from serial number 4000 VENTImotion 2 VENTI-O 2 plus O 2 switching valve for: VENTImotion from serial number 4000 VENTIlogic from serial number 4000 VENTImotion 2 Device description and operating instructions Overview VENTI-O 2 plus with therapy

More information

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment) Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air Types: PE 200-TE PE 250-TE PE 300-TE Production status: F02 PE 250-TE with compressor control (optional equipment) General Medium

More information

Alcotest Breath Alcohol Screening Device. Operator Instructions for Use. ST _sw.eps

Alcotest Breath Alcohol Screening Device. Operator Instructions for Use. ST _sw.eps D Alcotest 6510 Breath Alcohol Screening Device Operator Instructions for Use ST-207-2004_sw.eps Contents Contents................................................. 2 For your safety............................................

More information

OPERATOR s MANUAL AHCON PCI 3000

OPERATOR s MANUAL AHCON PCI 3000 OPERATOR s MANUAL AHCON PCI 3000 1 INDEX Page Manufacturer s Information 3 Warnings 4 Risks and Labelling 5 Safety Precautions 5 Warranty 6 Dimensions and Weight 7 Shipping Dimensions 7 Connection 8 Operation

More information

encurve Operator s Manual Short-wave Therapy Equipment CAUTION: Users must read this manual carefully and thoroughly before using this product.

encurve Operator s Manual Short-wave Therapy Equipment CAUTION: Users must read this manual carefully and thoroughly before using this product. Technology for Beauty and Health encurve Short-wave Therapy Equipment Operator s Manual CAUTION: Users must read this manual carefully and thoroughly before using this product. 1/5 Technology for Beauty

More information

OPERATION MANUAL PNEUMATIC VALVES

OPERATION MANUAL PNEUMATIC VALVES OPERATION MANUAL PNEUMATIC VALVES DIRECTIVE 2014/34/EU ATEX ENGLISH Index 1 Product identification 2 Security 3 Guarantee 4 Transportation 5 Assemblage 6 Setting up 7 Adjustments 8 Technical information

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

Instructions for Installation, Use and Maintenance FSI Safety Tank Shower Systems

Instructions for Installation, Use and Maintenance FSI Safety Tank Shower Systems Instructions for Installation, Use and Maintenance FSI Safety Tank Shower Systems per DIN 12 899 T1-3 and ANSI Z 358-2004 Table of Contents for Instructions for Use Section 1 Manufacturer, Safety Shower

More information

OXY 3690 MP. Measuring transducer for air oxygen

OXY 3690 MP. Measuring transducer for air oxygen T02.0.4X.6C-11 Measuring transducer for air oxygen OXY 3690 MP as of version V1.3 operating manual OXY 3690 MP - LO WEEE-Reg.-Nr. DE 93889386 GHM Messtechnik GmbH Standort Greisinger Hans-Sachs-Str. 26

More information

for the of and the EM55-1

for the of and the EM55-1 Operating Manua al for the Tapping Points of the EM55-1/EM55-2/EM55-3/ /EM55-4 series and the EE55-1/EE55-2/EE55-3/EE55-4 series EM55-1 Contents Contents... 2 1. Introduction... 3 1.1 General... 3 1.2

More information

DENAS Reflexo (p.21 40)

DENAS Reflexo (p.21 40) TRONITEK LLC, Ekaterinburg, Russia External therapeutic foot electrode DENAS Reflexo (p.21 40) Operation manual TRTK 06.13-03.71-01 RE TABLE OF CONTENTS Part 1. Technical passport 1. General description....3

More information

Safety instructions and operating manual

Safety instructions and operating manual 5-Master Safety instructions and operating manual TBF-PyroTec GmbH Lichterfelder Str. 5 A 21502 Geesthacht Tel.: + 49 (0)4152 157 9950 Fax: + 49 (0)4152 157 9951 Flame projector 5-Master Safety instructions

More information

PPS PORTABLE POWER SUPPLY

PPS PORTABLE POWER SUPPLY PPS User Manual Rev 1-2015 ENG MASTER PPS PORTABLE POWER SUPPLY Disclaimer About ActSafe Safety messages and warnings Product safety System description Pre-use inspection and connection General safety

More information

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124 Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124 13.7 Pressure Equipment Directive (PED) 97/23/EC 1 The Pressure Equipment Directive (PED) 97/23/EC applies to the design, manufacturing and conformity

More information

DYNAMIC COMPRESSION THERAPY

DYNAMIC COMPRESSION THERAPY PULSE PRESS DYNAMIC COMPRESSION THERAPY MULTITEC 12 User Manual May 2011 0120 CONTENTS:- SAFETY INSTRUCTIONS ELECTROMAGNETIC INTERFERENCE DESCRIPTION OF CONTROLS MODE SELECTION OPERATING INSTRUCTIONS CARE

More information

Operating and maintenance manual Filter and reducing station Series / 1.0

Operating and maintenance manual Filter and reducing station Series / 1.0 Operating and maintenance manual Filter and reducing station Series 961 04.2017 / 1.0 Original instructions ARCA Regler GmbH. All rights reserved. Cover picture background: Freepik.com ARCA Regler GmbH

More information

SBC 21. Electromagnetic Compatibility Information

SBC 21. Electromagnetic Compatibility Information SBC 21 D Blutdruckmessgerät : Gebrauchsanweisung...2 11 G Blood pressure monitor Instructions for use... 12 20 F Tensiomètre Mode d emploi...21 30 I Misuratore di pressione Istruzioni per l uso...31 40

More information

Operating Instructions

Operating Instructions Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table

More information

490 Micro GC Site Preparation Checklist

490 Micro GC Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

LC-SPE. Organizer 3.0 User Manual. Innovation with Integrity. Version 001 NMR

LC-SPE. Organizer 3.0 User Manual. Innovation with Integrity. Version 001 NMR LC-SPE Organizer 3.0 User Manual Version 001 Innovation with Integrity NMR Copyright by Bruker Corporation All rights reserved. No part of this publication may be reproduced, stored in a retrieval system,

More information

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATORS OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY GLOSSARY OF SYMBOLS. : ON (power switched on)

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATORS OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY GLOSSARY OF SYMBOLS. : ON (power switched on) OXYGEN CONCENTRATORS USER'S GUIDE OC4000 OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY I O : ON (power switched on) : OFF (power switched off) : Class II protection : Do not expose to open flames GLOSSARY

More information

Operating instructions - Translation of the original -

Operating instructions - Translation of the original - Operating instructions - Translation of the original - 3-way ball cock Type 403x KIESELMANN GmbH Paul-Kieselmann-Str.4-10 D - 75438 Knittlingen +49 (0) 7043 371-0 Fax: +49 (0) 7043 371-125 www.kieselmann.de

More information

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS VERTICAL AIR COMPRESSORS MODEL NO: VE11C150, VE15C150, VE18C150 PART NO: 2226005, 2226000, 2226015 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE Vertical

More information

Safety data sheet. Useable for: MS U-5200 Aldosterone Urine

Safety data sheet. Useable for: MS U-5200 Aldosterone Urine Useable for: MS U-5200 Aldosterone Urine Supplementary Kit These Assays contain no hazardous substances in concentrations to be declared, a labeling is not required. 1/8 1 Identification of the substance

More information

Supplementary Installation and Operating Instructions. Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex. Category: II 2G Ex IIC II 3G Ex IIC

Supplementary Installation and Operating Instructions. Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex. Category: II 2G Ex IIC II 3G Ex IIC Supplementary Installation and Operating Instructions Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex Category: II 2G Ex IIC II 3G Ex IIC Contents 1 General safety directions...3 2 Main safety features...4

More information

Model UB-328. Wrist Digital Blood Pressure Monitor. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

Model UB-328. Wrist Digital Blood Pressure Monitor. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni Wrist Digital Blood Pressure Monitor Model UB-328 Instruction Manual Manuel d instructions Manual de Instrucciones Manuale di Istruzioni WM+PD4000913 ENGLISH Dear Customers Congratulations. You have purchased

More information

Operating Manual VSA100A. tina29e1 ( )

Operating Manual VSA100A. tina29e1 ( ) Operating Manual Incl. EU Declaration of Conformity Vacuum Switch VSA100A tina29e1 (2017-05) 1 Product Identification In all communications with INFICON, please specify the information on the product nameplate.

More information

Nitrogen Supply System

Nitrogen Supply System ATMOSCOPE Nitrogen Supply System NS500 Users Guide Copyright 2001 EDSYN, INC. ATMOSCOPE Nitrogen Supply Systems TABLE OF CONTENTS Introduction............................. 3 General Information.......................

More information

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC 05 Elster GmbH Edition 0.5 Translation from the German 058 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Linear flow control VFC Linear flow control with actuator IFC Contents

More information