THE POWERFUL LEAK DETECTOR FOR ALL APPLICATIONS IN POWER PLANTS
|
|
- Dwight Daniels
- 5 years ago
- Views:
Transcription
1 THE POWERFUL LEAK DETECTOR FOR ALL APPLICATIONS IN POWER PLANTS
2 Use of HeliTest GEN for location of leaks on the steam circuit of a turbine of a working power plant INTRODUCTION Power plant turbines, regardless of the type of fuel used to generate heat in the boiler system, are turned by the steam generated by these boilers. The boiler heats pure water and converts it to steam which flows through the turbine in order to generate rotation of the power generator. After exiting the turbine, the steam is routed through a condenser which cools the steam to water. This water is returned to the boiler to start the cycle again. Typically the high pressure region of the turbine is working at a pressure of about 200 bar, while the low pressure region is working at a pressure of 35 to 50 mbar. Because of the leaks that are inherently present in this type of system, a vacuum pump (ejector pump or water ring pump or a combination of the two) is used to maintain the low pressure region at the required values. If a leak is being generated and causes an increase of the pressure in the low pressure region, it is absolutely important to immediately locate it and repair it, since a small increase of some millibars can cause a consistent loss in the efficiency of the plant. Various test methods have been used up to now; they range from very crude and low efficiency methods up to the use of ultrasonic detectors, which do not fit well within a very noisy plant environment, or to the use of freon detectors, which require isolation of the part under test from the system, and must be abandoned because of atmospheric pollution restrictions. THE NEW TEST METHOD RECOMMENDED BY VARIAN Varian is proposing a method based on helium as a tracer gas, which allows easy and quick location of leaks, and is therefore the best method to insure proper operation of power plants low pressure steam systems. The use of helium is advantageous because it is non-toxic, non flammable, relatively inexpensive, and quickly diffuses through small leaks. In addition, helium is non reactive with other chemicals and, because of its low concentration in the atmosphere (only 5 ppm), very small leaks can be detected without the possibility of error. This method allows the maintenance engineer the flexibility to perform leak tests while the plant is operational, without the need to isolate the sections under test, and a single operator can perform the full test. The detector recommended for this application is the Varian HeliTest GEN, derived from the basic HeliTest leak detector, used in many industrial applications, and well known for its high sensitivity to helium and its reliability in operation. HeliTest GEN Connection to System NOT CONDENSIBLE GASES OUTLET (AT ATMOSPHERIC PRESSURE) CONDENSER VACUUM PUMP HeliTest GEN
3 HeliTest GEN Benefits The HeliTest GEN is a self-contained, rugged and easy-to-use leak detector, specifically designed to perform leak detection and leak location in power plant applications. Most important benefits of this instrument are: HIGH SENSITIVITY The HeliTest GEN is sensitive to 2 ppm of helium, equivalent to 5 x 10-6 atm cc/sec. This roughly corresponds to one cubic centimeter of air escaping from the leak every week or to a bubble escaping every day. HIGH SELECTIVITY The HeliTest GEN is only sensitive to helium, therefore no false signals created by the presence of any other gases are possible. SIMPLE OPERATION No specific operator training is required. The unit is designed to allow leak detection and leak location be performed by a single operator. RUGGED CONSTRUCTION Designed for continuous operation in industrial areas. HIGH RELIABILITY Varian long experience with HeliTest leak detector has allowed design of a very reliable instrument. Every time the unit is switched on, it automatically performs an autocheck cycle to ensure proper operation. AUTOZERO Use of automatic or manual zeroing system allows detection of leaks even in high helium backgroud environment. HeliTest GEN Operation He PROBE He H 2 O FILTERS HeliTest DETECTOR SPRAY TIME RESPONSE TIME LEAK L2 LEAK L1 SYSTEM READY TRANSMITTER RECEIVER BASIC UNIT PORTABLE LEAK INDICATOR
4 THE HELITEST GEN PRINCIPLE OF OPERATION The HeliTest GEN is a leak detector based on what is called Selective Ion Pump Detector (SIPD). The principle of operation of this new technology is based on a special silica 1 2 HeliTest GEN Basic Unit 3 4 membrane which, if heated to a given temperature, becomes permeable to helium, because of its small molecule, but not to other gases. An ion pump will detect and display a signal proportional to the quantity of helium that has permeated through the silica membrane, and this 5 signal will be diplayed showing the helium leak rate. This system of operation is highly sensitive, due to the very low pressure in the ion pump (10-9 mbar), and very reliable, due to the absence of moving parts. In the HeliTest GEN a sample of the gas to be tested is pulled from the pipe or other object under test towards the sensor from a sampling pump. If this gas sample contains any helium, it will be detected by the basic unit, and a leak signal will be shown, allowing not only to determine its relative size, but most importantly to locate its position. The Portable Leak Indicator, that can be carried up to 2,000 (600 m) away from the basic unit, will show a signal indicating that a leak has been found. The leak can be then rapidly repaired and equipment operation restaured in the shortest possible time Sampling line 2 Power 3 Auxiliary pump switch 4 Auxiliary pump power 5 Leak signal 6 Recorder output 7 Bypass push-button 8 Leak signal transmitter
5 HOW TO PERFORM A TEST IN A POWER PLANT USING THE HELITEST GEN The HeliTest GEN allows performing leak detection and the specific location of leaks in the shortest possible time, and can be operated by a single person. In order to use this instrument, here is a short description of the operations to be performed. 1) The HeliTest GEN basic unit must be connected to the system under test. It is enough to connect the outlet of the vacuum pump to the HeliTest GEN inlet port. 2) After having connected the HeliTest GEN Basic Unit to the system to be checked, the operator starts to inspect the system and carries the HeliTest GEN Portable Leak Indicator. The indicator is then used by the operator to spray helium to the suspected areas, and to record the delay time for the helium signal to appear in case of a leak. 3) When helium enters the system through a leak, it is detected by the HeliTest GEN and the leak signal is shown both on the front panel of the unit and on the HeliTest GEN Portable Leak Indicator, which acts as a radio signal receiver. This signal will indicate both the size and the location of the leak. The operator can continue the search until all leaks are detected and located. The helium spray time and the response time are substantially dependent from the plant configuration and dimensions, and also from the distance between the check point to the place where the detector is located. Typically the helium spray time ranges from 15 to 30 seconds, and the response time, that is the time necessary to get a leak signal, from 20 to 90 seconds. The spray time and response time are also shown on the Portable Leak Indicator. OTHER APPLICATIONS OF THE HELITEST GEN IN POWER PLANTS In a power plant other leak checking jobs are often required, and they can generally be safely and easily performed using the HeliTest GEN. Besides leak checking the heat exchangers, we can mention the power transformers and related equipment, as well as leak checking underground pressurized power cables. These cables can be generally easily tested even if placed underground, thanks to the high diffusivity of helium, which can 1 HeliTest GEN Portable Leak Indicator 2 3 move upwards from the leak location, allowing its detection without need to dig any holes on the ground Receiver 2 Leak signal response time display 3 Helium spray time display 4 Helium spray pipe 5 Ready signal 6 Spray Helium button 6
6 HeliTest GEN Specifications A- BASIC UNIT Lowest detectable helium concentration: Lowest detectable leak rate: Warmup time including self-check up: Power requirements: Maximum input power: 2 ppm (parts per million) 5 x 10-6 atm cc/sec 3 minutes 115 / 230 V, 50 / 60 Hz 400 VA Operating conditions : Temperature: 0 C to 40 C Relative humidity: 90% maximum Distance between transmitter and receiver: Maximum 2,000 (600 m) Dimensions: 20.8 x 6.9 x 22.8 h (mm 530 x 175 x 580 h) Weight: 45 lb (20 kg) B - PORTABLE LEAK INDICATOR (AND RECEIVER) Fitting for helium supply pipe: Diameter 0.24 (6 mm) Operating conditions Temperature: 0 C to 40 C Relative humidity: 90% maximum Power requirement Portable Leak Indicator: 4 x 1.5 V AA batteries Receiver: 1 x 9V battery (4 hours of continuous operation) Dimensions: Portable Leak Indicator: 8.3 x 1.8 x 3.9 (mm 210 x 45 x 100) Receiver: 9.5 x 2.8 x 1.4 (mm 240 x 70 x 35) Weight Portable Leak Indicator: 1.0 lb (0.4 kg) Receiver: 1.1 lb (0.5 kg) HeliTest GEN Ordering Information Description Part Number HeliTest GEN, complete package, 230 V operation HeliTest GEN, complete package, 115 V operation Varian Offices AUSTRALIA Varian Australia Pty Ltd. 6/81 Frenchs Forest Road Frenchs Forest NSW 2086 Australia Telephone: (61) Fax: (61) BENELUX Varian Vacuum Technologies Rijksstraatweg 269 H, 3956 CP Leersum The Netherlands Telephone: (31) Fax: (31) CANADA Varian Canada Inc Millcreek Drive, Unit 5 Mississauga, Ontario L5N 5R9 Canada Telephone: (905) Fax: (905) Toll free: CHINA Varian Technologies Asia, Ltd. Rm Concordia Plaza 1 Science Museum Rd Tsimshatsui East, Kowloon Hong Kong Telephone: (852) Fax: (852) FRANCE & WALLONIE Varian s.a. 7, Avenue des Tropiques Z.A. de Courtaboeuf B.P. 12 F91941 Les Ulis Cedex - France Telephone: (33) Fax: (33) GERMANY, AUSTRIA Varian Deutschland GmbH Vacuum Technologies Alsfelder Strasse 6 Postfach Darmstadt - Germany Telephone: (49) Fax: (49) INDIA Varian India Pvt. Ltd. 101 Competent House 7, Nangal Raya Business Centre New Delhi India Telephone: (91) Fax: (91) ITALY Varian S.p.A. Vacuum Technologies Sales Office Via Varian Leinì (Torino) Italy Telephone: (39) Fax: (39) JAPAN Varian Technologies Japan Sumitomo Shibaura Bldg Shibaura Minato ku Tokyo 108 Japan Telephone: (81) Fax: (81) KOREA Varian Technologies Korea, Ltd. Head Office Shinsa 2 nd Bldg. 2F, Daechi-Dong, Kangnam-Seoul Korea Telephone: (82) Fax: (82) TAIWAN Varian Technologies Asia, Ltd. Taiwan Branch 18F-13 No. 79, Sec. 1, Hsin Tai Wu Rd. Hsi Chih, Taipei Hsien, Taiwan Telephone: (886) Fax: (886) U.K. & IRELAND Varian Ltd. 28 Manor Road Walton on Thames Surrey KT12 2QF U.K. Telephone: (44) Fax: (44) USA, SOUTH & CENTRAL AMERICA Varian Vacuum Technologies 121 Hartwell Avenue Lexington, MA USA Telephone: (781) Fax: (781) Toll free: OTHER COUNTRIES Varian S.p.A. Vacuum Technologies Sales Office Via Varian Leinì (Torino) Italy Telephone: (39) Fax: (39) Samho Syscom Ent. / VAC-T027-E (Printed in Italy) 09/00 All specifications are subject to change without notice - Copyright by Varian SpA
Advanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) VS Series Leak Detectors for Vacuum Furnaces Rate of rise and vacuum decay tests will not locate leaks, they will only
More informationThe PHD-4 Portable Helium Detector. Wide range, High Performance System
The PHD-4 Portable Helium Detector Wide range, High Performance System The Agilent Advantage Global Application Support Expertise When & Where You Need It Thousands of portable SIPD sniffing helium detectors
More informationThe New PHD 4 Portable Helium Detector
The New PHD 4 Portable Helium Detector SPECIAL FEATURES: High Sensitivity to Helium Easy to Use Truly Portable Versatile Dependable The system is designed to allow easy replacement of sampling line components
More informationh2000 plus HyDROGEN LEAk DETECTOR
H2000 plus hydrogen leak detector hydrogen leak detector h2000 plus Fast, easy to use, and durable. Leak testing with Hydrogen tracer gas The Hydrogen Method Detecting leaks using Hydrogen, called the
More information563 Ionization Gauge Tube
vacuum technologies 563 Ionization Gauge Tube INSTRUCTION MANUAL Manual No. 699905563 Revision B July 2002 563 Ionization Gauge Tube Copyright 2002 Varian Vacuum Technologies Warranty Products manufactured
More information564 Ionization Gauge Tube
vacuum technologies 564 Ionization Gauge Tube INSTRUCTION MANUAL Manual No. 699905564 Revision C December 2002 564 Ionization Gauge Tube Copyright 2002 Varian Vacuum Technologies Preface Warranty Products
More information571 Ionization Gauge Tube
vacuum technologies 571 Ionization Gauge Tube INSTRUCTION MANUAL DRAFT 12/13/02 Manual No. 699905571 Revision C December 2002 571 Ionization Gauge Tube DRAFT 12/13/02 Copyright 2002 Varian Vacuum Technologies
More informationColumbus Instruments
0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011
More informationManual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany
Manual Degasser DDG-75 April 2007 1 Manual Online Degasser DDG-75 DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE-68766 Hockenheim Germany Tel. +49-6205-9450-0 Fax. +49-6205-9450-33 email info@duratec.com
More informationAdvantages of Carrier Gas Leak Detection using Novel Helium or Hydrogen Leak Detectors with Specific Sensor Types
19 th World Conference on Non-Destructive Testing 2016 Advantages of Carrier Gas Leak Detection using Novel Helium or Hydrogen Leak Detectors with Specific Sensor Types Klaus HERRMANN 1, Daniel WETZIG
More informationOXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:
OXY Integral INTERCON ENTERPRISES INC Tel: 800 665 6655 Fax: 604 946 5340 E-Mail: sales@intercononline.com Internet: www.intercononline.com Manual Integral 2006 1 INDEX 2-3 PREFACE 4 INTRODUCTION 5 Principle
More informationInstruction Manual. Digital Thermocouple Gauge Control Units Models DTC & DTC Models DTC-06M-115 & DTC-06M-230
Instruction Manual Digital Thermocouple Gauge Control Units Models DTC-531-115 & DTC-531-230 Models DTC-06M-115 & DTC-06M-230 Copyright 1998 by Duniway Stockroom Corp. 021315lh 1 of 7 Table of Contents
More informationOn-Stream Tightness Testing of Vacuum Process Installations
ECNDT 2006 - Tu.2.6.3 On-Stream Tightness Testing of Vacuum Process Installations André de JONGE, Leak Detection Group, DCI Meettechniek B.V., Kapelle, The Netherlands DCI Meettechniek. -DCI was founded
More informationVS Series Leak Detectors for Vacuum Furnaces LEAK DETECTION FOR VACUUM FURNACES
VS Series Leak Detectors for Vacuum Furnaces LEAK DETECTION FOR VACUUM FURNACES VS Series Leak Detectors for Vacuum Furnaces indicate the presence of a leak. If the vacuum level is slow to reach the original
More informationGA / 3.02 TL 4 TL 6. Cat. No Calibrated leaks GA / 3.02 TL 4 TL 6. Cat. No
O P E R A T I N G I N S T R U C T I O N S GA 10.18 / 3.02 TL 4 TL 6 Cat. No. 155 65 155 66 Calibrated leaks O P E R A T I N G I N S T R U C T I O N S GA 10.18 / 3.02 TL 4 TL 6 Cat. No. 155 65 155 66 Calibrated
More informationPHOENIX L300i Best-in-class Helium Leak Detectors
180.85.02 Best-in-class Helium Leak Detectors The perfect Helium leak detector matching your demands The helium leak detector opens up new dimensions of productivity and reliability for your applications.
More informationCOSMO INSTRUMENTS CO., LTD.
Specification Sheet COSMO AIR LEAK TESTER ModelLS-1861 Meets SI Unit Requirement Improved accuracy with the new Master-Preset compensation feature Compensates for environmental changes Improves cycle time
More informationYour local gas generation partner. Precision series Modular gas generation solution for GC.
Your local gas generation partner Precision series Modular gas generation solution for GC www.peakscientific.com Perform with Precision Specifically designed and engineered for GC laboratory applications,
More informationModel Description
LEAKHUNTER Plus LEAKHUNTER Plus Model 8066 Description The MATHESON LEAKHUNTER Plus is a truly universal leak detector. Extensive R&D has produced a multi-functional leak detector engineered to perform
More informationcombustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring
combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring Flue Gas Oxygen Genesis is a range of flue gas analyzers for measuring Oxygen
More informationDIAPHRAGM VACUUM PUMPS AND COMPRESSORS
DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET N 186 N 186.1.2 ST.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down
More informationYour local gas generation partner. Precision series Modular gas generation solution for GC.
Your local gas generation partner Precision series Modular gas generation solution for GC www.peakscientific.com Perform with Precision Specifically designed and engineered for GC laboratory applications,
More informationThe latest automotive systems require innovative leak test methods and fixturing.
Leak Testing Auto Parts The latest automotive systems require innovative leak test methods and fixturing. In the past, automobile manufacturers only required basic forms of leak testing to check standard
More informationcombustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company
combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring An Company Flue Gas Oxygen Genesis is a range of flue gas analyzers for measuring
More informationLEAK DETECTION SOLUTIONS FOR POWER GENERATION AND CHEMICAL PLANTS
LEAK DETECTION SOLUTIONS FOR POWER GENERATION AND CHEMICAL PLANTS POWERGeneration LEAK TESTING by Agilent Power Generation Air leaks in power plant condensers, even small ones, can cause a significant
More informationCOMPACT HIGH PERFORMANCE HELIUM LEAK DETECTORS ASM 182 SERIES
COMPACT HIGH PERFORMANCE HELIUM LEAK DETECTORS COMPACT HIGH PERFORMANCE HELIUM LEAK DETECTORS The most powerful leak detectors on the market to meet demanding applications needs The ASM 182 Series: a unique
More informationSeries IRV1000/2000/3000
CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one
More informationPRESENTATION OF LEAKSHOOTER LKS1000-V2 01/2017
PRESENTATION OF LEAKSHOOTER LKS1000-V2 guy@synergys-technologies.com 01/2017 Authorized dealer BeNeLux A-measure bvba Cuylitsstraat 94 B-2018 Antwerpen info@a-measure.be www.a-measure.be 0032(0)475/33
More informationDräger P7 Pressure, Leak and Leak Rate Measurement
Dräger P7 Pressure, Leak and Leak Rate Measurement The gas field entails many dangers and requires maximum safety. This industry has a corresponding number of test standards. Play it safe with the Dräger
More informationVariable Leak Valve. Model User Manual
Variable Leak Valve Model 951-5106 User Manual 87-400-085-01 (D) 05/2011 Notices Agilent Technologies, Inc. 2011 No part of this manual may be reproduced in any form or by any means (including electronic
More informationPropane Conversion Kit Instruction
Propane Conversion Kit Instruction Condensing gas boiler Required Input Rates GB42-24 84,800 btu/hr Tab. GB42-30 06,000 btu/hr GB42-45 49,000 btu/hr GB42-60 24,800 btu/hr This kit and instructions are
More information7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications
GE Sensing & Inspection Technologies 7250 Sys Ruska Multi-Range Pressure Calibration System Features Fully integrated multi-range pressure test and calibration systems Select either an eight range or the
More informationAIR SAVING PRODUCTS ADDING VALUE AIR-SAVER LOCATOR LOCATOR-EV
AIR SAVING PRODUCTS AIR-SAVER LOCATOR LOCATOR-EV ADDING VALUE REL LIABLE COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS Air saving products INDEX Chapter Content 1 Introduction to compressed
More informationLEAKHUNTER Plus Model 8066
LEAKHUNTER Plus LEAKHUNTER Plus Model 8066 Description The Matheson LEAKHUNTER Plus is a truly universal leak detector. Extensive R&D has produced a multi-functional leak detector engineered to perform
More informationDIAPHRAGM GAS SAMPLING PUMPS
DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 0150 N 0150 SP.9 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central point
More informationInstruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar
Instruction Manual D356-10-880 Issue G Original CG16K Barometrically Compensated Capsule Dial Gauge Description CG16K Capsule Dial Gauge, 0 to 1040 mbar CG16K Capsule Dial Gauge, 0 to 125 mbar CG16K Capsule
More informationWorkhorse-15 Oxygen Generator
11436 Sorrento Valley Road, San Diego CA 92121 USA 858-558-0202 Fax 858-558-1915 Workhorse-15 Oxygen Generator Model No. 5719, 5727, 5735 for Domestic and International Units Part number 1432 Revision
More informationInstruction and Maintenance Manual
Instruction and Maintenance Manual GRYF OXY ZM 02/100/2 E Contact GRYF HB, spol. s r.o. Cechova 314 Havlickuv Brod 580 01 tel.: +420 569 426 627 fax: +420 569 426 627 www.gryf.eu ver.: 11.2.2015 OEM module
More informationHOW WISE TECHNOLOGY WORKS INFICON Protec P3000 sensor powered by Wise Technology, consists of an evacuated gas cell covered by a quartz membrane.
EASY AND COMFORTABLE TO USE FOR FOOLPROOF OPERATION After the initial setup, there is no need to access the base unit, which frees the operator to concentrate on the sniffing process. All relevant messages
More informationMODEL GT820 OXYGEN SENSOR
INSTRUCTION MANUAL MODEL GT820 OXYGEN SENSOR 70046 The information and technical data disclosed by this document may be used and disseminated only for the purposes and to the extent specifically authorized
More informationCHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS
CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 922 N 922 FTE Concept The diaphragm pumps from KNF are based on a simple principle - an elastic diaphragm, ixed on its edge, moves up and
More informationCOMPRESSED AIR SAVING PRODUCTS INDEX. Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR. Condensate Management Specialist
INDEX Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR COMPRESSED AIR SAVING PRODUCTS Condensate Management Specialist Information provided herewith is believed to be accurate and reliable. However,
More informationPropane Conversion Kit Instruction
Propane Conversion Kit Instruction Condensing gas boiler Required Input Rates GB142-24 84,800 btu/hr GB142-30 106,000 btu/hr GB142-45 160,900 btu/hr GB142-60 214,800 btu/hr This kit and instructions are
More informationCHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS
CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 9 N 9 FTE Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its
More informationHelium Leak Detection in High Pressure Urea Reactor
Helium Leak Detection in High Pressure Urea Reactor ALI AL SIYABI & ANKIT NIRANJAN OMAN INDIA FERTILIZER COMPANY OMAN Oman India Fertilizer Company was commissioned in April 2005. The performance in the
More informationProtec P3000 (XL) Helium Sniffer Leak Detector
Protec P3000 (XL) Helium Sniffer Leak Detector AC C U R AT E, R E L I A B L E L E A K DETECTION AT A DISTANCE Sniffer leak detection you can rely on INFICON Protec P3000 and Protec P3000XL Helium Sniffer
More informationInstruction and Maintenance Manual
Instruction and Maintenance Manual GRYF OXY Z 02/100/2 E Contact GRYF HB, spol. s r.o. Cechova 314 Havlickuv Brod 580 01 tel.: +420 569 426 627 fax: +420 569 426 627 Czech Republic www.gryf.eu Technical
More informationInformation Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100
Information Sheet PlasmaPro Estrelas100 About this information sheet This data sheet provides basic information about the installation of a PlasmaPro Estrelas100 tool. Some of the information in this sheet
More informationChemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200
Specification Bulletin (rev.01) Series CH4200 Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200 Easy, fast& accurate digital with 11 points calibration Laser sensor offering actual feed
More informationIRwin Methane Leak Detector. Innovation makes the difference
IRwin Methane Leak Detector Innovation makes the difference Innovative methane detector system for easy survey of gas pipelines IRwin is a portable methane leak detector for fast and easy survey of gas
More informationA portable tool to detect leaks in large diameter pipes AGBAR
A portable tool to detect leaks in large diameter pipes Francisco Aguado AGBAR São Paulo, June 8 th, 2010 Project context (1/2) Common (acoustic) leak detection systems can not be used in many cases: Plastic
More informationKMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N
Thermal Mass Flow Meter for Compressed Air and Gases measuring monitoring analysing KMT Measuring range: 0.32... 63 m3n/h... 3.5... 1400 m3 N /h Accuracy: ±2,5% of reading + 0,15% of full scale p max :
More informationRelative and differential pressure module type 698
Relative and differential pressure module type 698-5... 5 mbar / 0... 1 10000 mbar The pressure modules type 698 are suitable for monitoring pressure and flow in air conditioning systems and in the laboratory
More informationTH-1800-T TRX-700-CNG Converter
TH-1800-T TRX-700-CNG Converter low detector The CNG fuel gas flowmeter is so accurate as to meet a demand of measuring the CNG directly by making the most use of our well-established mini-thermal flowmeter
More informationInstruction Manual Dräger MSI P7 and MSI P7 plus
Dräger MSI GmbH Rohrstraße 32 58093 Hagen Tel.: +49-2331 / 9584-0 Fax: +49-2331 / 9584-29 e-mail: info@draeger-msi.de D 923; Edition 2011-01-01 Content 1. General Hints Page 4 2. The Instrument 2.1 Front
More informationLocator Locator-D-Lux Air-Saver G1 Air-Saver G2
170663_air_saving_products 17-02-2011 16:42 Pagina 1 Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 AIR SAVING PRODUCTS 170663_air_saving_products 17-02-2011 16:42 Pagina 2 170663_air_saving_products
More informationAIR-SAVER G1 AIR-SAVER G2 LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS
AIR-SAVER G1 AIR-SAVER G2 LOCATOR-EV ENVIRONMENT ADDING VALUE SAFEGUARD RELIABLE COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS Air saving products INDEX Chapter Content
More informationAIR-SAVER G1 AIR-SAVER G2 LOCATOR LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS
AIR-SAVER G1 AIR-SAVER G2 LOCATOR LOCATOR-EV ENVIRONMENT ADDING VALUE SAFEGUARD RELIABLE COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS AIR SAVING PRODUCTS INDEX Chapter
More informationPropane Conversion Kit Instruction
Propane Conversion Kit Instruction Condensing gas boiler Required Input Rates Logamax plus GB62-80 kw 270,000 btu/hr Logamax plus GB62-00 kw 35,000 btu/hr This kit and instructions are for converting the
More informationDF-550E PROCESS ANALYSERS APPLICATIONS FEATURES
PROCESS ANALYSERS DF-550E The DF-550E Nano Trace oxygen analyser is a Coulometric sensor based analyser designed to measure oxygen as a contaminant at ultra trace levels in ultra high purity electronic
More informationHighest Quality. Gas Chlorination Systems
Highest Quality Gas Chlorination Systems Application: Gas chlorination systems are used for water disinfection and other purposes in a variety of applications. Compared to other disinfection methods, chlorine
More informationAdditel 761 Automated Pressure Calibrators
Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure
More informationMINI GAS SAMPLING PUMPS WITH DOUBLE DIAPHRAGM SYSTEM
MINI GAS SAMPLING PUMPS WITH DOUBLE DIAPHRAGM SYSTEM DATA SHEET E 081 N 86 AN.12DC-B Concept Double diaphragm pumps from KNF are based on a simple principle: an elastic working membrane and safety membrane
More informationUsing the UltraRAE. Firmware 2.35
Using the UltraRAE Firmware 2.35 Training Agenda UltraRAE features Setting up the UltraRAE Turning on the UltraRAE Idle Operation RAE-Sep Tubes Prepping for a measurement Taking a measurement Alarm modes
More informationFor Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor
Cat No AP3-KA-C Two-color digital display pressure sensor AP-3 Series Digital Display & Digital Control For Air Pressure EASY-TO-SEE 2-color display Green and red two-color LED display clearly shows abnormal
More informationIntegral type Differential pressure flowmeter VNT Series
Integral type Differential pressure flowmeter VNT Series OUTLINE VH series Wafer-Cone differential pressure flowmeter and high precision differential pressure transmitter are integrated into one flowmeter.
More informationPressure Reducing & Desuperheating (PRDS) Station Pressure Reducing (PRS) Station Desuperheating (DSH) Station. Ver. 1.1 (2016)
Pressure Reducing & Desuperheating (PRDS) Station Pressure Reducing (PRS) Station Desuperheating (DSH) Station Ver. 1.1 (2016) Pressure Reducing & Desuperheating (PRDS) Station Modular Ready-to-Fit Conditioning
More informationElectro-Pneumatic Converter YT-940 SERIES
Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product
More informationNGP-250/500 Nitrogen Generator Quick Start Guide
NGP-250/500 Nitrogen Generator Quick Start Guide Version: A July 2013 Potter Electric Signal Company, LLC 5757 Phantom Dr., Suite 125 P. O. Box 42037 Hazelwood, MO 63042 Phone: (314) 595-6900 Document
More informationYour local gas generation partner. Precision series Modular gas generation solution for GC.
Your local gas generation partner Precision series Modular gas generation solution for GC www.peakscientific.com Perform with Precision Specifically designed and engineered for GC laboratory applications,
More informationThe HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator
The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Universal pycnometer, no
More informationVentam 85 Installation & Commissioning Instructions
Ventam Systems Ltd Unit D4 Seedbed Business Centre Vanguard Way Shoeburyness Essex SS3 9QY Phone 01702 382 307 Fax 01702 382 340 Ventam 85 Installation & Commissioning Instructions 1 General The Ventam
More informationPlasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling
SERVOPRO Plasma The SERVOPRO Plasma is a Plasma Emission Detector based analyser designed to continuously measure Nitrogen in pure Argon for process and quality control in Argon production within Cryogenic
More informationGas Clean. Filters. Delivering Clean Gases for GC and GC/MS Operation
Gas Clean Filters Delivering Clean Gases for GC and GC/MS Operation Gas Clean Filters Fast, leak-free replacement without tools! Each Gas Clean Filter features a unique quick disconnect design which allows
More informationMEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet
Data sheet MEGAS 2.0 Gas analysis with direct C-Level Calculation and Bus-Connection Mesa Industrie-Elektronik GmbH Neckarstraße 19, D-45768 Marl info@mesa-gmbh.de +49 (0) 2365-97 45 1-0 +49 (0) 2365-97
More informationDF-310E PROCESS ANALYSERS APPLICATIONS FEATURES
PROCESS ANALYSERS DF-310E The DF-310E is a Coulometric sensor based oxygen analyzer designed to measure trace and percent level oxygen in pure and multi-gas backgrounds for process and quality control
More informationSpirax Compact FREME Flash Recovery Energy Management Equipment
IM-UK-cFREME UK Issue 1 Spirax Compact FREME Flash Recovery Energy Management Equipment Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4.
More informationSPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan
SPECIFICATIONS PARTICLE SENSOR KS-18F 3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan No. 05083-5E 18-01 Printed in Japan Outline The KS-18F is a sensor which uses the light scattering method
More informationAMT-Ex Dewpoint Transmitter
AMT-Ex Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk
More informationADT 761 Automated Pressure Calibrator
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com With a built-in high performance electronic pump and precision pressure controller,
More informationGasSense NDIR User Manual
INDEX INDEX... 1 1. OVERVIEW... 2 2. TECHNICAL DATA... 3 3. SPECIFICATIONS... 4 4. PRODUCT DESCRIPTION... 5 4.1 Mechanical details... 5 4.2 Piping... 7 4.3 Connections... 7 5. INSTALLATION... 10 6. CALIBRATION
More informationGPP model GPPT model GPC model CLP model
CHOOSING A CALIBRATOR FOR HELIUM LEAK DETECTORS Unique Vacuum Solutions deals with four models of Calibrated Leak Standards for calibrating Helium Leak Detectors and Leak Testing Systems so that one is
More informationDextens Thermo Conductivity Sensors. Type 52101, 54101, 55101
Dextens Thermo Conductivity Sensors Type 52101, 54101, 55101 Operating Manual May 2012 Table of Content 1 GENERAL INFORMATION...4 1.1 DISCLAIMER...4 1.2 SYMBOLS AND CONVENTIONS...4 1.3 SERVICES AND REPAIRS...4
More informationManual of SF6 Comprehensive Tester
Manual of SF6 Comprehensive Tester Important Description All the staff taking in charge of the usage or maintenance of this product should carefully read this manual. The same as any other complicated
More informationTechnical Information Conducal CLY421
TI00496C/07/EN/01.12 71142150 Products Solutions Services Technical Information Conducal CLY421 Conductivity calibration set for ultrapure water applications Factory calibrated measurement box Certified
More informationPART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:
PART 1 GENERAL 1.1 DESCRIPTION.1 This section includes the supply, delivery and installation, testing and placement into operation of a gas chlorination system, and appurtenances as specified herein and
More informationSensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual
Sensor for Air Bubble Detection at Liquid Filled Tubes SONOCHECK Type ABD06.xx Operating Manual Manufacturer: Model: Type: SONOTEC Ultraschallsensorik Halle GmbH Air Bubble Detector ABD06.xx SONOTEC Ultraschallsensorik
More informationdeltaflowc deltaflowc Venturi or Probe
deltaflowc Mass Flowmeter for Gases - Multivariable with ultra fast dp, p and T-sensors - Compact, accurate and user-friendly - Ideal for OEMs deltaflowc Venturi or Probe Precise mass flow metering deltaflowc
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) DOCUMENT NO: STP 2203 VERSION: 2008-07-01 Page 1 of 6 1.0 PURPOSE This test procedure is used by the Electrical Safety
More informationAdditel 761 Automated Pressure Calibrators Selection Guide
/ Process Calibration Equipment Automated Calibrators Selection Guide Model Features Range Module 1 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP -2.5 to 2.5 mbar (-1 to 1 inh 2 O) -0.95
More informationEuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases
P r o d u c t i n f o r m at i o n EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total
More informationHydroCOM: High energy savings and excellent controllability
HydroCOM: High energy savings and excellent controllability Almost all applications require efficient capacity control systems Most of them simply waste energy, are slow and inaccurate. HydroCOM, however,
More informationH 2. Sensor Series Take no risk! Install a Hydrogen Sensor in your Gaschromatograph
Sensor Series 9000 Take no risk! Install a Hydrogen Sensor in your Gaschromatograph Carrier Gases for GC Probably more than 90% of the present GC instruments run with helium as carrier gas. Some people
More informationGA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300
Technical Note GA-300 Overview The GA-300 CO2 and O2 Gas Analyzer is easy to use, robust, and adaptable to human, animal, and plant applications. The GA-300 has two analog outputs to allow recording and
More informationSPECIFICATIONS PARTICLE SENSOR KS-19F Higashimotomachi, Kokubunji, Tokyo , Japan
SPECIFICATIONS PARTICLE SENSOR KS-19F 3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan No. 13012-3E 17-06 Printed in Japan Outline The KS-19F is a sensor which uses the light scattering method
More informationChlorinator MODEL MK-I
Chlorinator MODEL MK-I The New model MK- I is semi automatic gas type. Vacuum operated Solution feed Chlorinator designed to provide a continues & measured quantity of gas while in operation. It is suitable
More information* Analysis of TCG ( Total Combustible Gas ) and 6 kinds of Gases * High Sensitivity for C 2
Portable DGA Dissolved Gas Analyzer MITSUBISHI Portable Dissolved Gas Analyzer (PGA-300) is used to analyze 6 kinds of dissolved gases in transformer oil, thereby improving prompt action
More informationApplications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples
Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples Outline of Presentation Introduction Process Gas Analysis Magnetic Sector Mass Spectrometer Standard
More informationDr. Tetsuzo KITAGAWA, Tokihiko YONEDA, Shigefumi NAKAJIMA. 1. Preface
PORTABLE BREATH ALCOHOL ANALYZER BY NDIR METHOD Dr. Tetsuzo KITAGAWA, Tokihiko YONEDA, Shigefumi NAKAJIMA KOMYO RIKAGAKU KOGYO K. K. 2-14,2-chome, Nakane, Meguro-ku, Tokyo 152, Japan 1. Preface For the
More informationOxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.
Oxford Instruments Plasma Technology www.oxford-instruments.com About this data sheet This data sheet provides basic information about the installation of a tool. Floor and wall loadings Table 1 lists
More information