CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

Size: px
Start display at page:

Download "CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS"

Transcription

1 CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 922 N 922 FTE Concept The diaphragm pumps from KNF are based on a simple principle - an elastic diaphragm, ixed on its edge, moves up and down its central point by means of an eccentric. In this way the medium is transferred using automatic valves. The gas-bearing parts of the chemically resistant gas pumps are made of modiied PTFE, so they are able to withstand even highly aggressive gases and vapors. The N 922 FT.29 E does have an integrated bypass valve to adjust the low rate to the current process conditions. N 922 FT.29 E low rate can be adjusted using an integrated bypass valve Features Pure transfer, evacuation and compression of air, gases and vapors No contamination of the media due to oil-free operation Maintenance-free Chemically resistant for transferring highly aggressive and corrosive gases and vapors High level of gas tightness: approx. 6 x 10-3 mbar. l/s Long product life Very quiet and little vibration Cool running motor even when in constant use Version with adjustable low rate Can operate in any installed position Areas of use These pumps are required especially in the ields of chemistry industry, environmental and production technology as well as research. Beside other applications, pumps are used for gas measurement, for example for sampling gases from the ambient environment, or for exhaust gas and smoke analysis. PERFORMANCE DATA Type Delivery (l/min) Vacuum (mbar absolute) atm. pressure Pressure (bar g) N 922 FTE 16 ± 10 % N 922 FT.29 E ± 10 % Weight (kg)

2 HINTS ON FUNCTION AND INSTALLATION Function of KNF diaphragm vacuum pumps and compressors An elastic diaphragm is moved up and down by an eccentric (see illustration). On the down-stroke it draws the air or gas being handled through the inlet valve. On the up-stroke the diaphragm forces the medium through the exhaust valve and out of the head. The compression chamber is hermetically separated from the drive mechanism by the diaphragm. The pumps transfer, evacuateand compress completely oil-free. Hints on installation and operation Range of use: Transferring air and gases at temperatures between +5 C and +50 C. Permissible ambient temperature: between +5 C and +60 C. Please check the compatibility of the materials of the pump head, diaphragm and valves with the medium. The standard pumps are not suitable for use in areas where there is a risk of explosion. In these cases there are other products in the KNF program - please ask us for details. The pumps are not designed to start against pressure or vacuum; when a pump is switched on the pressure in the suction and pressure lines must be atmospheric. Pumps that start against pressure or vacuum are available on request. To prevent the maximum operating pressure being exceeded, restriction or regulation of the air low should only be carried out in the suction line. Components connected to the pump must be designed to withstand the pneumatic performance of the pump. Install the pump so that the fan can draw in suficient cooling air. KNF reserves the right to make technical changes. KNF Neuberger GmbH Alter Weg 3 D Freiburg Tel Fax info@knf.de KNF 07/2017 (Produced in Germany)

3 N 922 FTE PERFORMANCE DATA Type Delivery at atm. pressure (l/min) 1) Max. operating pressure (bar g) Ultimate vacuum (mbar abs.) N 922 FTE 16 ± 10 % ) Liter at STP MOTOR DATA Protection class IP 55 IP 55 IP 55 Voltage (V) ~ 230/400 Frequencies (Hz) 50/60 50/60 50/60 Power P1 (W) lmax (A), 50/60 Hz /0.48 PUMP MATERIAL Type Pump head Diaphragm Valves/Sealing N 922 FTE modiied PTFE PTFE-coated FFPM N 922 FTE N 922 FTE FLOW CAPACITY Vacuum atm. pressure Pressure Flow capacity l/min (Liter at STP) mbar abs. bar g

4 N 922 FT.29 E PERFORMANCE DATA Type Delivery at atm. pressure (l/min) 1) Max. operating pressure (bar g) N 922 FT.29 E ± 10 % ) Liter at STP Ultimate vacuum (mbar abs.) MOTOR DATA Protection class IP 55 IP 55 IP 55 Voltage (V) ~ 230/400 Frequencies (Hz) 50/60 50/60 50/60 Power P1 (W) lmax (A), 50/60 Hz /0.48 PUMP MATERIAL Type Pump head Diaphragm Valves/Sealing N 922 FT.29 E modiied PTFE PTFE-coated FFPM N 922 FT.29 E N 922 FT.29 E FLOW CAPACITY Vacuum atm. pressure Pressure Flow capacity l/min (Liter at STP) mbar abs. bar g

5 TECHNICAL INFORMATION N 922 FTE N 922 FT.29 E PUMP UP TIME FOR 20 LITER VESSEL bar min N 922 FTE N 922 FT.29 E PUMP DOWN TIME FOR 20 LITER VESSEL mbar abs. min ACCESSORIES Description Order No. Tube itting for tube ID6, PVDF Mounting kit shock mounts Mounting kit shock mounts and mounting bracket

6 YOUR LOCAL PARTNER AROUND THE WORLD KNF SALES ORGANIZATION Australia KNF Regional Office Moreland West VIC 3055 Tel info@knf.com.au Benelux Netherlands KNF Verder B.V GG Vleuten Tel info@knf-verder.nl India KNF Pumps + Systems (India) Pvt. Ltd. Hinjewadi Pune Tel info@knfpumps.in Italy KNF Italia S.r.l Cernusco s. Naviglio (MI) Tel info@knf.it Singapore KNF Regional Office Tel info@knf.com.sg Sweden, Finland, Denmark, Norway KNF Neuberger AB Stockholm Tel info@knf.se Benelux Belgium and Luxemburg KNF Verder N.V Aartselaar Tel info@knf.be China KNF Technology (Shanghai) Co., Ltd. Shanghai Tel info@knf.com.cn France KNF Neuberger SAS Village-Neuf Tel info@knf.fr Germany KNF Neuberger GmbH Freiburg Tel info@knf.de Japan KNF Japan Co. Ltd. Tokyo Tel info@knf.co.jp Korea KNF Neuberger Ltd Seoul Tel knf@knfkorea.com Latin America KNF Regional Office Tel gb@knf.com Morocco, Tunisia, Algeria KNF Neuberger SAS Village-Neuf Tel info@knf.fr Switzerland KNF Neuberger AG 8362 Balterswil Tel knf@knf.ch UK, Ireland KNF Neuberger U.K., Ltd. Witney, Oxfordshire OX28 4FA Tel info@knf.co.uk USA, Canada KNF Neuberger, Inc. Trenton, NJ Tel knfusa@knf.com KNF PRODUCT CENTERS Gas Pumps KNF Neuberger GmbH DE Freiburg info@knf.de Micro Gas Pumps KNF Micro AG CH-6260 Reiden info@knf-micro.ch Liquid Pumps KNF Flodos AG CH-6210 Sursee info@knf-flodos.ch

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 9 N 9 FTE Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET N 186 N 186.1.2 ST.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down

More information

DIAPHRAGM GAS SAMPLING PUMPS

DIAPHRAGM GAS SAMPLING PUMPS DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 0150 N 0150 SP.9 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central point

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 23 N 26.1 ANE Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 14 N 22 ANE Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central

More information

DIAPHRAGM VACUUM PUMPS WITH KNF STABILIZATION SYSTEM

DIAPHRAGM VACUUM PUMPS WITH KNF STABILIZATION SYSTEM DIAPHRAGM VACUUM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 015 N 920 APE-W Automatic voltage adjustment for worldwide use (as an option with external signal input). N 920 APDC-B with brushless DC

More information

GAS SAMPLING PUMPS WITH KNF DOUBLE DIAPHRAGM SYSTEM

GAS SAMPLING PUMPS WITH KNF DOUBLE DIAPHRAGM SYSTEM GAS SAMPLING PUMPS WITH KNF DOUBLE DIAPHRAGM SYSTEM DATA SHEET E065 Cutaway - Double diaphragm pump Concept The Diaphragm Vacuum Pumps from KNF are based on a simple principal - an elastic diaphragm, fixed

More information

N SERIES PROCESS VACUUM PUMPS AND COMPRESSORS

N SERIES PROCESS VACUUM PUMPS AND COMPRESSORS N 186.1.2 SERIES PROCESS VACUUM PUMPS AND COMPRESSORS ADVANTAGES Twofold safety: The combination of a working diaphragm and an additional safety diaphragm prevents gas from escaping in the event of a fracture

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 16 N 35 ANE with IP 2 motor Concept The diaphragm pumps from KNF are based on a simple principal - an elastic diaphragm, ixed on its edge, moves up and

More information

MINI GAS SAMPLING PUMPS WITH DOUBLE DIAPHRAGM SYSTEM

MINI GAS SAMPLING PUMPS WITH DOUBLE DIAPHRAGM SYSTEM MINI GAS SAMPLING PUMPS WITH DOUBLE DIAPHRAGM SYSTEM DATA SHEET E 081 N 86 AN.12DC-B Concept Double diaphragm pumps from KNF are based on a simple principle: an elastic working membrane and safety membrane

More information

MINI DIAPHRAGM VACUUM PUMPS

MINI DIAPHRAGM VACUUM PUMPS MINI DIAPHRAGM VACUUM PUMPS DATA SHEET E 024 N 815 KNE N 828 KNDC-B N 838 KNDC Concept The mini diaphragm gas sampling pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge,

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E030 N 145.2 ANE Concept The Diaphragm Pumps from KNF are based on a simple principal - an elastic diaphragm, fixed on its edge, moves up and down its

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS N26.1, N26.2, N26.3 N 26.1 ANE Concept The Diaphragm Vacuum Pumps from KNF are based on a simple principal - an elastic diaphragm, fixed on its edge, moves up and

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 2400 N 2400.15 ST.9 E Concept The diaphragm pumps from KNF arebased on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 143 N 143 SP.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET N 186 N 186.1.2 ST.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down

More information

DIAPHRAGM GAS SAMPLING PUMPS

DIAPHRAGM GAS SAMPLING PUMPS DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET E 059 N 0150 AP.9E N 0150.3 AP.9E N 0150 SP.12E Double diaphragm pump Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm,

More information

MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 010 N 89 KNDC N 811 KNE N 814 KNE Concept The mini diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge,

More information

MICRO DIAPHRAGM GAS PUMPS

MICRO DIAPHRAGM GAS PUMPS MICRO DIAPHRAGM GAS PUMPS DATA SHEET E 5 NMP 83 KNE NMP 85 KNDC NMP 85.1.2 KNDC-B Concept The micro diaphragm gas pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge,

More information

MINI DIAPHRAGM VACUUM PUMPS

MINI DIAPHRAGM VACUUM PUMPS MINI DIAPHRAGM VACUUM PUMPS DATA SHEET E 024 N 815 KNE N 828 KNDC-B N 838 KNDC Concept The mini diaphragm gas sampling pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its

More information

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 037 N 940.5 APE as AC version in IP 54 N 940.5 APE-W with multi-voltage power supply input (As an option adjustable with potentiometer or by external

More information

MICRO DIAPHRAGM GAS PUMPS

MICRO DIAPHRAGM GAS PUMPS MICRO DIAPHRAGM GAS PUMPS DATA SHEET E 5 NMP83KNE NMP85KPDC NMP85.1.2KPDC-B Concept The micro diaphragm gas pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge, moves

More information

Diaphragm-Gas Sampling Pumps with double diaphragm System N 0150 AN.12 E N 0150 ST.12 E N AN.12 E N ST.12 E

Diaphragm-Gas Sampling Pumps with double diaphragm System N 0150 AN.12 E N 0150 ST.12 E N AN.12 E N ST.12 E Operating and Installation Instructions Read and observe these Operating and Installation Instructions! Diaphragm-Gas Sampling Pumps with double diaphragm System N 0150 AN.12 E N 0150 ST.12 E N 0150.1.2

More information

Diaphragm Vacuum Pumps and Compressors

Diaphragm Vacuum Pumps and Compressors Diaphragm Vacuum Pumps and Compressors N 022 ANE N 026 ANE N 026.1 ANE N 026.2 ANE N 026.3 ANE N 022 AN.9 E N 026 AN.9 E N 026.1 ATE N 026.2 ATE N 026.3 ATE N 022 ATE N 026 ATE N 026.1 AVE N 026.2 AVE

More information

Willkommen. Welcome to KNF - presentation

Willkommen. Welcome to KNF - presentation Willkommen Welcome to KNF - presentation KNF modular system, way to Project pump heads available in: - aluminium - plastics (PPS, Peek ) - stainless steel - PTFE diaphragms und valves available in: - Neopren

More information

Diaphragm-Gas Sampling Pumps with double diaphragm System N 143 AN.12 E N 143 AV.12 E. N 143 SN.12 E N 143 SV.12 E Operating and

Diaphragm-Gas Sampling Pumps with double diaphragm System N 143 AN.12 E N 143 AV.12 E. N 143 SN.12 E N 143 SV.12 E Operating and Diaphragm-Gas Sampling Pumps with double diaphragm System N 143 AN.12 E N 143 AV.12 E N 143 SN.12 E N 143 SV.12 E Operating and Installation Instructions Read and observe these Operating and Installation

More information

Diaphragm Vacuum Pump

Diaphragm Vacuum Pump Operating Instructions Read and observe these Operating Instructions! Diaphragm Vacuum Pump N920 AP.18 N920 AP.29.18 N920 KT.29.18G KNF Neuberger GmbH Alter Weg 3 D-79112 Freiburg Germany Phone +49-(0)7664

More information

Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps in compact design Liquid ring vacuum pumps in compact design LEM 26, LEM 51 Pressure range: Suction volume flow: 33 to 113 mbar 3 to 58 m³/h CONSTRUCTION TYPE SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated

More information

Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860

Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860 PROCESS Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860 Single & Twin-Head Designs OEM Installation Models UN860FTI EX UN726.3STI EX UN726.3FTI

More information

Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps in compact design Liquid ring vacuum pumps in compact design LEM 25, LEM 5 Pressure range: Suction volume flow: 33 to 113 mbar 4 to 6 m³/h CONSTRUCTION SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated

More information

Liquid ring vacuum pumps single-stage

Liquid ring vacuum pumps single-stage Liquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 Pressure range: Suction volume flow: 150 to 1013 mbar 50 to 270 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum pumps are displacement

More information

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in

More information

Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps in compact design Liquid ring vacuum pumps in compact design, Pressure range: Suction volume flow: 33 to 113 mbar 3 to 58 m³/h CONSTRUCTION TYPE SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated and

More information

SCH-27. Diaphragm Pressure Switch. Setting range: mbar to bar. Temperature: max C. Material: stainless steel

SCH-27. Diaphragm Pressure Switch. Setting range: mbar to bar. Temperature: max C. Material: stainless steel Diaphragm Pressure Switch measuring monitoring analysing SCH-27 P3 Setting range: 0.7... 6 mbar to 8... 160 bar Temperature: max. +100 C Material: stainless steel Connection: G ½ male, ½" NPT male, ¼"

More information

Liquid ring compressors

Liquid ring compressors Liquid ring compressors KPH 85220, KPH 85227 Compression pressures: Suction volume flow: 2 to 7 bar 940 to 1450 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors

More information

Auxiliary Valve PRS6 Pressure Reducing Valve. Catalogue HY /UK June 2003

Auxiliary Valve PRS6 Pressure Reducing Valve. Catalogue HY /UK June 2003 Auxiliary Valve Pressure Reducing Valve June 2003 General Subject to alteration without prior notice. The curves and diagrams in this catalogue are typical examples only. While the contents of the catalogue

More information

Liquid ring compressor

Liquid ring compressor Liquid ring compressor KLH 47005, KLH 47105 Compression pressures: Suction volume flow: 2 to 11 bar 56 to 65 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors of

More information

CAT-W Iwaki pneumatic drive bellows pumps

CAT-W Iwaki pneumatic drive bellows pumps CAT-W 0051-01 Iwaki pneumatic drive bellows pumps For Ultrapure Chemical Delivery in Semiconductor Processing The F series comprises pneumatic drive bellows pumps designed for use in semiconductor manufacturing

More information

Series IRV1000/2000/3000

Series IRV1000/2000/3000 CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one

More information

MICRO DIAPHRAGM LIQUID PUMPS DATA SHEET NF 100/1.100 NF 100 / 1.100

MICRO DIAPHRAGM LIQUID PUMPS DATA SHEET NF 100/1.100 NF 100 / 1.100 MICRO DIAPHRAGM LIQUID PUMPS DATA SHEET /1.100 / 1.100 KP.51 DC NF 1.100 KPE KP.27 AA Concept KNF diaphragm liquid pumps are based on the principle of the oscillating displacement pump which is remarkably

More information

SIHI LPH-X - Liquid Ring Compressors

SIHI LPH-X - Liquid Ring Compressors - Liquid Ring Compressors LPH 50523 LPH 60527 Pressure range: Suction volume range: 0.2 to 1.5 bar 260 to 780 m³/h CONSTRUCTION Sterling SIHI liquid ring compressors are displacement compressors with a

More information

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic Pharmaceutical SRL Series Oil-less Scroll Air Compressors Research & Development Food & Beverage Chemical Electronic Hitachi Industrial Equipment Product Brochure Hitachi SRL Series scroll compressors

More information

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment) Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air Types: PE 200-TE PE 250-TE PE 300-TE Production status: F02 PE 250-TE with compressor control (optional equipment) General Medium

More information

ASB Accumulator Safety Blocks

ASB Accumulator Safety Blocks ASB Accumulator Safety Blocks For working pressures up to 350 bar Catalogue HY07-1241/UK Note: In line with our policy of continuing product improvement, specifications in this catalogue are subject to

More information

Best Practices for Installation of Gaseous Sample Pumps

Best Practices for Installation of Gaseous Sample Pumps Best Practices for Installation of Gaseous Sample Pumps Goal of the Gas Sample Pump Transport a clean, reliable, sample of the process gas to the analyzer, in the safest and easiest way possible, to ensure

More information

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version 2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version Type 6624 Impulse can be combined with... 10mm width orifice DN 0.8 to 1.2 with pressure range vacuum to 5bar medium separation, for

More information

ALPHADYNAMIC has filed with the TUV NORD certification body the documentation certifying

ALPHADYNAMIC has filed with the TUV NORD certification body the documentation certifying ATEX COMPLIANCE ALPHADYNAMIC has filed with the TUV NORD certification body the documentation certifying ATEX compliance pursuant to Directive 94/9/EC for its ranges of ADB BOXER pneumatic diaphragm pumps.

More information

Diaphragm Accumulators

Diaphragm Accumulators 1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydro-pneumatic accumulators for storing fluids.

More information

EQUAFLUX - PRODUCTION PROGRAM INDUSTRIAL PUMPS SINCE 1982 FDA. Made in Italy. TÜV NORD Italia S.r.l. compliant

EQUAFLUX - PRODUCTION PROGRAM INDUSTRIAL PUMPS SINCE 1982 FDA. Made in Italy. TÜV NORD Italia S.r.l. compliant INDUSTRIAL PUMPS SINCE 1982 R EQUAFLUX - PRODUCTION PROGRAM TÜV NORD Italia S.r.l. ISO 9001 FDA compliant Made in Italy EQUAFLUX MAIN FEATURES: Available in PP, PVDF, PPS-V, AISI 316, Alu Automatic dampening

More information

Differential pressure gauge For the process industry Model , all-metal media chamber

Differential pressure gauge For the process industry Model , all-metal media chamber Pressure Differential pressure gauge For the process industry Model 732.51, all-metal media chamber WIKA data sheet PM 07.05 for further approvals see page 4 Applications For gaseous and liquid aggressive

More information

HydroCOM: High energy savings and excellent controllability

HydroCOM: High energy savings and excellent controllability HydroCOM: High energy savings and excellent controllability Almost all applications require efficient capacity control systems Most of them simply waste energy, are slow and inaccurate. HydroCOM, however,

More information

Compressed Airline Breathing Apparatus

Compressed Airline Breathing Apparatus Compressed Airline Breathing Apparatus [ The Independence in Breathing] The Complete Range at a Glance Full face mask with lung governed demand valve Light duty airline breathing apparatus Cavair LDA Pressure

More information

h2000 plus HyDROGEN LEAk DETECTOR

h2000 plus HyDROGEN LEAk DETECTOR H2000 plus hydrogen leak detector hydrogen leak detector h2000 plus Fast, easy to use, and durable. Leak testing with Hydrogen tracer gas The Hydrogen Method Detecting leaks using Hydrogen, called the

More information

AREA TOTALS OECD Composite Leading Indicators. OECD Total. OECD + Major 6 Non Member Countries. Major Five Asia. Major Seven.

AREA TOTALS OECD Composite Leading Indicators. OECD Total. OECD + Major 6 Non Member Countries. Major Five Asia. Major Seven. Reference series Composite leading indicators OECD Composite Leading Indicators AREA TOTALS 7-03- 19 OECD Total 19 OECD + Major 6 Non Member Countries 19 Major Seven 19 Major Five Asia 19 Euro area 19

More information

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT CAUTION!

More information

DIAPHRAGM PRESSURE CONTROL VALVE FDV 30 / 31, FDV 1.30 / 1.30 FDV 300 / 301, FDV / 1.301

DIAPHRAGM PRESSURE CONTROL VALVE FDV 30 / 31, FDV 1.30 / 1.30 FDV 300 / 301, FDV / 1.301 DIAPHRAGM PRESSURE CONTROL VALVE FDV 30 / 31, FDV 1.30 / 1.30 FDV 300 / 301, FDV 1.300 / 1.301 FDV 31 KP Z A: Pump Accessories KP/KP.51 / KV / KT / TV / TT 30 / 1.30 / 31 / 1.31 / 300 / 1.300 / 301 / 1.301

More information

Premium Solutions for Gas and Biogas Handling

Premium Solutions for Gas and Biogas Handling Premium Solutions for Gas and Biogas Handling Blower Solutions for Gas & Biogas Type of gas Applications Application requisites Specific characteristics of the blower unit Premium Solutions for Gas and

More information

cooled, Heated ATH 2800 MT, DN 250 ISO-F, External drive electronics, Water cooled, Heated

cooled, Heated ATH 2800 MT, DN 250 ISO-F, External drive electronics, Water cooled, Heated ATH 2800 MT, DN 250 ISO-F, External drive electronics, Water cooled, Heated ATH 2800 MT, DN 250 ISO-F, External drive electronics, Water cooled, Heated ATH 2800 MT, DN 250 ISO-F, External drive electronics,

More information

CAMASS. Calibration Centre. Gas flow technology and services

CAMASS. Calibration Centre. Gas flow technology and services CAMASS Calibration Centre Gas flow technology and services CAMASS Calibration technology for gas flow measurement and control When using technologically sophisticated systems to measure and control gases,

More information

Auxiliary Valve QDS6 Sequence Valve, 3-way. Catalogue HY /UK June 2003

Auxiliary Valve QDS6 Sequence Valve, 3-way. Catalogue HY /UK June 2003 Auxiliary Valve equence Valve, 3-way Catalogue HY17-8542/UK June 2003 General ubject to alteration without prior notice. he curves and diagrams in this catalogue are typical examples only. While the contents

More information

Series ZFC. Air Suction Filter. In-line Type with One-touch Fittings

Series ZFC. Air Suction Filter. In-line Type with One-touch Fittings CAT.E832- A Air Suction Filter In-line Type with One-touch Fittings An in-line type air suction filter that prevents trouble in vacuum equipment due to contaminants in the air IN/OUT straight piping Saves

More information

Medium-sized vessels water connection. White paper

Medium-sized vessels water connection. White paper Medium-sized vessels water connection White paper Flamco B.V. January 2017 Medium-sized vessels water connection In practice you will find expansion vessels with the water connection on bottom, and with

More information

THE POWERFUL LEAK DETECTOR FOR ALL APPLICATIONS IN POWER PLANTS

THE POWERFUL LEAK DETECTOR FOR ALL APPLICATIONS IN POWER PLANTS THE POWERFUL LEAK DETECTOR FOR ALL APPLICATIONS IN POWER PLANTS Use of HeliTest GEN for location of leaks on the steam circuit of a turbine of a working power plant INTRODUCTION Power plant turbines, regardless

More information

Liquid Ring Compressors Engineered-to-Order Compressor Systems

Liquid Ring Compressors Engineered-to-Order Compressor Systems Liquid Ring Compressors Engineered-to-Order Compressor Systems NASH Liquid Ring Compressor Systems Engineered-to-Order Liquid Ring Compressor Systems Unmatched experience Nash liquid ring compressors are

More information

BSS 2 Bottle Sampling System. Instruction manual Version 1.8

BSS 2 Bottle Sampling System. Instruction manual Version 1.8 BSS 2 Bottle Sampling System Instruction manual Version 1.8 Serial-No.:... Version-/Rev.-Date : 12.06.2012 Contents 1. General... 3 2. Safety Instructions... 4 3. Extent of Delivery... 5 4. Switch Panel...

More information

CAMASS. Calibration Centre. Gas flow technology and services

CAMASS. Calibration Centre. Gas flow technology and services Calibration Centre Gas flow technology and services Calibration technology for gas flow measurement and control When using technologically sophisticated systems to measure and control gases, calibration

More information

Customer Responsibilities

Customer Responsibilities Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

Valve Proving System VDK 200 A S06*

Valve Proving System VDK 200 A S06* Valve Proving System VDK 200 A S06* Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

Valve Proving System VDK 200 A S02

Valve Proving System VDK 200 A S02 Valve Proving System VDK 200 A S02 Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

PRESSURE & TEMPERATURE GAUGES PRESSURE TEMPERATURE. Catalogue H20200a

PRESSURE & TEMPERATURE GAUGES PRESSURE TEMPERATURE. Catalogue H20200a PRESSURE & TEMPERATURE GAUGES PRESSURE Catalogue TEMPERATURE Applications The label Trafag Industrial Components extends the Trafag brand name to instruments manufactured by qualified partner companies.

More information

Liquid Ring Compressors Engineered-to-Order Compressor Systems

Liquid Ring Compressors Engineered-to-Order Compressor Systems Liquid Ring Compressors Engineered-to-Order Compressor Systems NASH Liquid Ring Compressors Greatest Performance Range of Liquid Ring Compressors Worldwide The ability to compress wet, saturated or dirty

More information

Diaphragm Accumulators

Diaphragm Accumulators Diaphragm Accumulators. DESCRIPTION.. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in HYDAC diaphragm accumulators

More information

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT

More information

SuperFinish 27. Available versions. Accessories. SuperFinish 27 Spraypack. Basic unit. Tip extensions / pole guns. Suction systems.

SuperFinish 27. Available versions. Accessories. SuperFinish 27 Spraypack. Basic unit. Tip extensions / pole guns. Suction systems. Available versions Spraypack Basic unit 0341 051 basic unit on trolley including pressure gauge system + QuickClean suction + 15 m high pressure hose + Airless gun G 12 + Wagner Tip holder with Airless

More information

Precise Finish. Fast Results. Easy to Use.

Precise Finish. Fast Results. Easy to Use. trimjet E Precise Finish. Fast Results. Easy to Use. The WINTERSTEIGER trimjet is an automatic edge grinding machine for skis and snowboards. Equipped with disc technology from the ski industry, the trimjet

More information

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar Instruction Manual D356-10-880 Issue G Original CG16K Barometrically Compensated Capsule Dial Gauge Description CG16K Capsule Dial Gauge, 0 to 1040 mbar CG16K Capsule Dial Gauge, 0 to 125 mbar CG16K Capsule

More information

Atmospheric Vent Silencers. Industrial & Marine Silencers

Atmospheric Vent Silencers. Industrial & Marine Silencers tmospheric Vent Silencers Industrial & Marine Silencers Maximum performance Minimum fuss Industrial and Marine Silencers (IMS) designs and builds products for organisations engaged in power generation,

More information

CNG FILLING STATIONS

CNG FILLING STATIONS CNG FILLING STATIONS GAS INLET 3/4 F EXIT CNG TO CAR TANK 5 mt / 16 feet HOSE AND FILLING NOZZLE REMOTE ELECTRIC PANEL THREE-PHASE height 40 cm / 15.7 width 30 cm / 11.8 depth 20 cm / 7.8 EQUIPPED WITH

More information

Flow and check valves Logic valves series 551. Brochure

Flow and check valves Logic valves series 551. Brochure Flow and check valves Logic valves series 551 Brochure 2 Flow and check valves Logic valves series 551 3/2-directional valve, low pressure operated Qn = 2-120 l/min 3 3/2-directional valve, Qn = 120 l/min

More information

COSMO INSTRUMENTS CO., LTD.

COSMO INSTRUMENTS CO., LTD. Specification Sheet COSMO AIR LEAK TESTER ModelLS-1861 Meets SI Unit Requirement Improved accuracy with the new Master-Preset compensation feature Compensates for environmental changes Improves cycle time

More information

Pressure gauges EN All stainless steel construction PBX100, PBX150 (1.18) Functional and constructive characteristics

Pressure gauges EN All stainless steel construction PBX100, PBX150 (1.18) Functional and constructive characteristics Pressure gauges FT PBX 100-150-E-9.02 All stainless steel construction PBX100, PBX150 (1.18) EN 837-1 These instruments are designed for use in food, beverage, pharmaceutical, cryogenics, chemical and

More information

DEWATERING PUMP SOLUTIONS. Pneumatic pumps

DEWATERING PUMP SOLUTIONS. Pneumatic pumps DEWATERING PUMP SOLUTIONS Pneumatic pumps PUMP UP YOUR BUSINESS A pneumatic pump is a great choice when failure is not an option. They re easy to use, safe and can handle almost anything you throw at them.

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

Diaphragm Accumulators

Diaphragm Accumulators Diaphragm Accumulators. DESCRIPTION.. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydraulic accumulators for storing

More information

Technical Specifications

Technical Specifications E_Trim91.qxp 16.12.2002 19:05 Uhr Seite 1 Either or! The correct edge sharpness can decide whether your client s next ski day will be a gripping experience or an embarasing succession of slips and slides.

More information

MP-F05, MP-F05/R, MP-F10, MP-F10/R

MP-F05, MP-F05/R, MP-F10, MP-F10/R Bellows pump series MP -F MP-F05, MP-F05/R, MP-F10, MP-F10/R Instruction Manual Version 1.04.00 Dear customer, Thank you for buying our product. In this manual you will find all necessary information about

More information

Instruction Manual Contact Pressure Vacuum Gauge

Instruction Manual Contact Pressure Vacuum Gauge MS10 Instruction Manual Contact Pressure Vacuum Gauge Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information

Automatic Control Unit. Cervomatic EDP.2. Type Series Booklet

Automatic Control Unit. Cervomatic EDP.2. Type Series Booklet Automatic Control Unit Cervomatic EDP.2 Type Series Booklet Legal information/copyright Type Series Booklet Cervomatic EDP.2 All rights reserved. The contents provided herein must neither be distributed,

More information

Happiness trends in 24 countries,

Happiness trends in 24 countries, Happiness trends in 4 countries, 1946-006 The following graphs shows the trends in happiness levels found in 4 countries, using comparable data from all available surveys for countries having at least

More information

SM Models Manual Control

SM Models Manual Control SM Models Manual Control Practical Choice for Solenoid-driven Pumps Models for chemical injection, high-pressure boiler feed, and outgassing fluids. Temperatures ranges (ambient and transferring liquid)

More information

Airless-Spraying Equipment. SuperFinish31. Fully equipped. More power. Innovative QLS technology

Airless-Spraying Equipment. SuperFinish31. Fully equipped. More power. Innovative QLS technology Airless-Spraying Equipment SuperFinish31 Fully equipped More power Innovative QLS technology New technology, fully equipped with even more power. This is the new SuperFinish 31 Airless spraying equipment,

More information

Solenoid valves VZWF, force pilot operated

Solenoid valves VZWF, force pilot operated Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is

More information

Basic & Controlled Atmosphere Glove Boxes

Basic & Controlled Atmosphere Glove Boxes I N T R O D U C T I O N Precise Basic and Controlled Atmosphere Glove Boxes provide a leak-tight environment for work with contamination-sensitive materials. Precise Basic Glove Boxes are simple, economical

More information

Max Sort Sortation Option - Letters

Max Sort Sortation Option - Letters Max Sort Sortation Option - Letters Western Europe Prices Product Code PS5 PS6 Austria* 0.330 7.550 0.330 7.400 Belgium* 0.370 3.700 0.370 3.540 Denmark* 0.620 5.350 0.620 4.215 Finland* 0.385 4.400 0.385

More information

Airless-spraying equipment. SuperFinish 23. Solid. Profitable. Innovative QLS technology

Airless-spraying equipment. SuperFinish 23. Solid. Profitable. Innovative QLS technology Airless-spraying equipment SuperFinish 23 Solid Profitable Innovative QLS technology The easily transported Airless spraying equipment for flexible use on the building site Innovative QLS technology reliable

More information

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order Process Pump /5 Series Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted areas.

More information

Mechanical Pressure Measurement

Mechanical Pressure Measurement Mechanical Pressure Measurement Differential Pressure Gauges Model GDP, Universal Version, with Diaphragm Element High Overpressure Safety PN 40, 100, 250 or 400 Applications Differential pressure measurement

More information

Types ACE95 and ACE95Sr Tank Blanketing Valves

Types ACE95 and ACE95Sr Tank Blanketing Valves Types ACE95 and ACE95Sr Tank Blanketing Valves Bulletin 74.1:ACE95 May 2010 W9133 W8155 Figure 1. Type ACE95 Tank Blanketing Valve Figure 2. Type ACE95Sr Tank Blanketing Valve Features Fully Balanced Pilot

More information

Pressure controls for hydro carbons, zone II applications, Type KPE

Pressure controls for hydro carbons, zone II applications, Type KPE MAKING MODERN LIVING POSSIBLE Technical brochure Pressure controls for hydro carbons, zone II applications, Type KPE KPE pressure controls for use in refrigeration and air conditioning systems with hydrocarbons

More information