MINI DIAPHRAGM VACUUM PUMPS

Size: px
Start display at page:

Download "MINI DIAPHRAGM VACUUM PUMPS"

Transcription

1 MINI DIAPHRAGM VACUUM PUMPS DATA SHEET E 024 N 815 KNE N 828 KNDC-B N 838 KNDC Concept The mini diaphragm gas sampling pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central point by means of an eccentric. In this way the medium is transferred using automatic valves. The pumps are equipped with the patented stress-optimized structured diaphragm, resulting in a high pneumatic performance, a durable product and compact size. Special valves ensure that the product can cope easily with vapor and condensation. Thanks to the KNF modular system, the parts used to transfer the gases can be made from materials with varying degrees of resistance. The pumps can be driven by either AC or DC motors. Features Uncontaminated low No contamination of the media due to oil-free operation Maintenance-free Compact size High performance High level of gas tightness Long product life Very quiet and little vibration Copes well with vapor and condensation Cool running motor even when in constant use Ready for assembly Can operate in any installed position Areas of use The mini diaphragm pumps offer a high level of performance despite their small size, as well as an excellent price performance ratio. They are required especially in the ields of analysis, medicine and production technology. The pumps are used for sucking gases, taking samples (even liquids in a ) and evacuating vessels and systems. The AC models are suited for use in machinery which is permanent or mainsoperated. Mini diaphragm pumps for portable and stand-alone equipment require DC power supplies. (l/min) ( absolute) atmospheric Pressure N 815 KNE N 815 KNDC N 828 KNDC N 828 KNDC-B N 828 KN.29DC-B N 828 KNE N 838 KNDC N 838 KNDC-B N 838 KN.29DC-B N 838 KNE Weight (kg)

2 N 815 KNDC N 815 KTDC at atm. N 815 KNDC N 815 KTDC ) Liter at STP ( abs.) N 815 KNE N 815 KTE at atm. N 815 KNE N 815 KTE ( abs.) Voltage 12 V 24 V lmax (A) Pump head Diaphragm Valves N 815 KNDC PPS CR EPDM N 815 KTDC PPS PTFE-coated FFPM Protection class IP 00 Voltage (V) 230 Frequencies (Hz) 50 Power P1 (W) 50 lmax (A) 0.55 Pump head Diaphragm Valves N 815 KNE PPS CR EPDM N 815 KTE PPS PTFE-coated FFPM N 815 KNDC N 815 KTDC N 815 KNE N 815 KTE N 815 KNDC N 815 KNE atm. atm. N 815 KTDC N 815 KTE atm. atm.

3 N 828 KN _ N 828 ANDC at atm. N 828 KNDC N 828 ANDC N 828 KNDC N 828 ANDC N 828 KNDC-B N 828 KN.29DC-B ) Liter at STP ( abs.) Voltage 12 V 24 V 24 V (DC-B) Protection class IP 20 Power P1 (W) 58 lmax (A) Pump head Diaphragm Valve plates/ N 828 KN... PPS EPDM FPM N 828 ANDC Aluminum EPDM FPM N 828 KNE N 828 ANE Protection class IP 00 Voltage (V) 230 Frequencies (Hz) 50 Power P1 (W) 100 lmax (A) 0.6 N 828 KNE N 828 ANE at atm. N 828 KNE N 828 ANE ( abs.) Pump head Diaphragm Valve plates/ N 828 KNE PPS EPDM FPM N 828 ANE Aluminum EPDM FPM 6 deep Direction of rotation Capacitor not assembled N 828 KNDC-B N 828 KN.29 DC-B G1/8(2x) schwarz / black "-" rot / red "+" ±2 Flachbandkabel (nur bei Motoren mit Drehzahlregelung und Signalausgang) Flat Flex Cable (controö wires, only at motors with full control) 138 Drehrichtung direction of rotation (4x) 7(2x) 5.5(2x) M4 Erdung Grounding N 828 KNDC N 828 ANDC N 828 KNE N 828 ANE atm. atm. N 828 KNDC-B N 828 KN.29 DC-B atm. N 828 KNDC-B N 828 KN.29DC-B

4 N 838 KN _ N 838 ANDC at atm. N 838 KNDC N 838 ANDC N 838 KNDC N 838 ANDC N 838 KNDC-B N 838 KN.29DC-B ) Liter at STP ( abs.) Voltage 12 V 24 V 24 V (DC-B) Protection class IP 20 Power P1 (W) 58 lmax (A) Pump head Diaphragm Valve plates/ N 838 KN... PPS EPDM FPM N 838 ANDC Aluminum EPDM FPM N 838 KNE N 838 ANE Protection class IP 00 Voltage (V) 230 Frequencies (Hz) 50 Power P1 (W) 100 lmax (A) 0.6 N 838 KNE N 838 ANE at atm. N 838 KNE N 838 ANE ( abs.) Pump head Diaphragm Valve plates/ N 838 KNE PPS EPDM FPM N 838 ANE Aluminum EPDM FPM N 838 KNDC-B N 838 KN.29 DC-B N 838 KNDC N 838 ANDC N 838 KNE N 838 ANE atm. atm. N 838 KNDC-B N 838 KN.29 DC-B atm. N 838 KNDC-B N 838 KN.29DC-B

5 TECHNICAL INFORMATION PUMP DOWN TIME 5 LITER VESSEL N 815 KNE PUMP DOWN TIME 10 LITER VESSEL N 828 KNE N 828 ANE PUMP DOWN TIME 10 LITER VESSEL N 838 KNE N 838 ANE ACCESSORIES Description Order No. Details Filter/Silencer G 1/8 (N 815) Filter/Silencer G 1/8 Hose connector G 1/8 / PA Hose connector G 1/8 / PVDF

6 HINTS ON FUNCTION AND INSTALLATION Function of KNF diaphragm gas sampling pumps An elastic diaphragm is moved up and down by an eccentric (see illustration). On the down-stroke it draws the air or gas being handled through the inlet valve. On the up-stroke the diaphragm forces the medium through the exhaust valve and out of the head. The compression chamber is hermetically separated from the drive mechanism by the diaphragm. The pumps transfer, evacuate and compress completely oil-free. Hints on installation and operation Range of use: Transferring air and gases at temperatures between +5 C and +40 C. Please check the compatibility of the materials of the pump head, diaphragm and valves with the medium. The KNF product line contains pumps suitable for pumping aggressive gases and vapors please contact us. Permissible ambient temperature: +5 C C. The standard pumps are not suitable for use in areas where there is a risk of explosion. In these cases there are other products in the KNF program please ask us for details. The pumps are not designed to start against or ; when a pump is switched on the in the suction and lines must be atmospheric. Pumps that start against or are available on request. To prevent the maximum operating being exceeded, restriction or regulation of the air low should only be carried out in the suction line. Components connected to the pump must be designed to withstand the pneumatic performance of the pump. Install the pump so that the fan can draw in suficient cooling air. Fit the pump at the highest point in the system, so that condensate cannot collect in the head of the pump that prolongs working-life. KNF reserves the right to make technical changes. KNF Neuberger GmbH Alter Weg 3 D Freiburg Tel Fax info@knf.de KNF 07/2017 (Produced in Germany)

7 YOUR LOCAL PARTNER AROUND THE WORLD KNF SALES ORGANIZATION Australia KNF Regional Office Moreland West VIC 3055 Tel info@knf.com.au Benelux Netherlands KNF Verder B.V GG Vleuten Tel info@knf-verder.nl India KNF Pumps + Systems (India) Pvt. Ltd. Hinjewadi Pune Tel info@knfpumps.in Italy KNF Italia S.r.l Cernusco s. Naviglio (MI) Tel info@knf.it Singapore KNF Regional Office Tel info@knf.com.sg Sweden, Finland, Denmark, Norway KNF Neuberger AB Stockholm Tel info@knf.se Benelux Belgium and Luxemburg KNF Verder N.V Aartselaar Tel info@knf.be China KNF Technology (Shanghai) Co., Ltd. Shanghai Tel info@knf.com.cn France KNF Neuberger SAS Village-Neuf Tel info@knf.fr Germany KNF Neuberger GmbH Freiburg Tel info@knf.de Japan KNF Japan Co. Ltd. Tokyo Tel info@knf.co.jp Korea KNF Neuberger Ltd Seoul Tel knf@knfkorea.com Latin America KNF Regional Office Tel gb@knf.com Morocco, Tunisia, Algeria KNF Neuberger SAS Village-Neuf Tel info@knf.fr Switzerland KNF Neuberger AG 8362 Balterswil Tel knf@knf.ch UK, Ireland KNF Neuberger U.K., Ltd. Witney, Oxfordshire OX28 4FA Tel info@knf.co.uk USA, Canada KNF Neuberger, Inc. Trenton, NJ Tel knfusa@knf.com KNF PRODUCT CENTERS Gas Pumps KNF Neuberger GmbH DE Freiburg info@knf.de Micro Gas Pumps KNF Micro AG CH-6260 Reiden info@knf-micro.ch Liquid Pumps KNF Flodos AG CH-6210 Sursee info@knf-flodos.ch

MINI GAS SAMPLING PUMPS WITH DOUBLE DIAPHRAGM SYSTEM

MINI GAS SAMPLING PUMPS WITH DOUBLE DIAPHRAGM SYSTEM MINI GAS SAMPLING PUMPS WITH DOUBLE DIAPHRAGM SYSTEM DATA SHEET E 081 N 86 AN.12DC-B Concept Double diaphragm pumps from KNF are based on a simple principle: an elastic working membrane and safety membrane

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 23 N 26.1 ANE Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central

More information

DIAPHRAGM GAS SAMPLING PUMPS

DIAPHRAGM GAS SAMPLING PUMPS DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 0150 N 0150 SP.9 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central point

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET N 186 N 186.1.2 ST.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down

More information

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 922 N 922 FTE Concept The diaphragm pumps from KNF are based on a simple principle - an elastic diaphragm, ixed on its edge, moves up and

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 14 N 22 ANE Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central

More information

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 9 N 9 FTE Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its

More information

DIAPHRAGM VACUUM PUMPS WITH KNF STABILIZATION SYSTEM

DIAPHRAGM VACUUM PUMPS WITH KNF STABILIZATION SYSTEM DIAPHRAGM VACUUM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 015 N 920 APE-W Automatic voltage adjustment for worldwide use (as an option with external signal input). N 920 APDC-B with brushless DC

More information

MINI DIAPHRAGM VACUUM PUMPS

MINI DIAPHRAGM VACUUM PUMPS MINI DIAPHRAGM VACUUM PUMPS DATA SHEET E 024 N 815 KNE N 828 KNDC-B N 838 KNDC Concept The mini diaphragm gas sampling pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 16 N 35 ANE with IP 2 motor Concept The diaphragm pumps from KNF are based on a simple principal - an elastic diaphragm, ixed on its edge, moves up and

More information

GAS SAMPLING PUMPS WITH KNF DOUBLE DIAPHRAGM SYSTEM

GAS SAMPLING PUMPS WITH KNF DOUBLE DIAPHRAGM SYSTEM GAS SAMPLING PUMPS WITH KNF DOUBLE DIAPHRAGM SYSTEM DATA SHEET E065 Cutaway - Double diaphragm pump Concept The Diaphragm Vacuum Pumps from KNF are based on a simple principal - an elastic diaphragm, fixed

More information

N SERIES PROCESS VACUUM PUMPS AND COMPRESSORS

N SERIES PROCESS VACUUM PUMPS AND COMPRESSORS N 186.1.2 SERIES PROCESS VACUUM PUMPS AND COMPRESSORS ADVANTAGES Twofold safety: The combination of a working diaphragm and an additional safety diaphragm prevents gas from escaping in the event of a fracture

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E030 N 145.2 ANE Concept The Diaphragm Pumps from KNF are based on a simple principal - an elastic diaphragm, fixed on its edge, moves up and down its

More information

MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 010 N 89 KNDC N 811 KNE N 814 KNE Concept The mini diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge,

More information

MICRO DIAPHRAGM GAS PUMPS

MICRO DIAPHRAGM GAS PUMPS MICRO DIAPHRAGM GAS PUMPS DATA SHEET E 5 NMP 83 KNE NMP 85 KNDC NMP 85.1.2 KNDC-B Concept The micro diaphragm gas pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge,

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS N26.1, N26.2, N26.3 N 26.1 ANE Concept The Diaphragm Vacuum Pumps from KNF are based on a simple principal - an elastic diaphragm, fixed on its edge, moves up and

More information

MICRO DIAPHRAGM GAS PUMPS

MICRO DIAPHRAGM GAS PUMPS MICRO DIAPHRAGM GAS PUMPS DATA SHEET E 5 NMP83KNE NMP85KPDC NMP85.1.2KPDC-B Concept The micro diaphragm gas pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge, moves

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 2400 N 2400.15 ST.9 E Concept The diaphragm pumps from KNF arebased on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 143 N 143 SP.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central

More information

DIAPHRAGM GAS SAMPLING PUMPS

DIAPHRAGM GAS SAMPLING PUMPS DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET E 059 N 0150 AP.9E N 0150.3 AP.9E N 0150 SP.12E Double diaphragm pump Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm,

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET N 186 N 186.1.2 ST.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down

More information

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 037 N 940.5 APE as AC version in IP 54 N 940.5 APE-W with multi-voltage power supply input (As an option adjustable with potentiometer or by external

More information

Diaphragm-Gas Sampling Pumps with double diaphragm System N 0150 AN.12 E N 0150 ST.12 E N AN.12 E N ST.12 E

Diaphragm-Gas Sampling Pumps with double diaphragm System N 0150 AN.12 E N 0150 ST.12 E N AN.12 E N ST.12 E Operating and Installation Instructions Read and observe these Operating and Installation Instructions! Diaphragm-Gas Sampling Pumps with double diaphragm System N 0150 AN.12 E N 0150 ST.12 E N 0150.1.2

More information

Diaphragm Vacuum Pumps and Compressors

Diaphragm Vacuum Pumps and Compressors Diaphragm Vacuum Pumps and Compressors N 022 ANE N 026 ANE N 026.1 ANE N 026.2 ANE N 026.3 ANE N 022 AN.9 E N 026 AN.9 E N 026.1 ATE N 026.2 ATE N 026.3 ATE N 022 ATE N 026 ATE N 026.1 AVE N 026.2 AVE

More information

Willkommen. Welcome to KNF - presentation

Willkommen. Welcome to KNF - presentation Willkommen Welcome to KNF - presentation KNF modular system, way to Project pump heads available in: - aluminium - plastics (PPS, Peek ) - stainless steel - PTFE diaphragms und valves available in: - Neopren

More information

Diaphragm-Gas Sampling Pumps with double diaphragm System N 143 AN.12 E N 143 AV.12 E. N 143 SN.12 E N 143 SV.12 E Operating and

Diaphragm-Gas Sampling Pumps with double diaphragm System N 143 AN.12 E N 143 AV.12 E. N 143 SN.12 E N 143 SV.12 E Operating and Diaphragm-Gas Sampling Pumps with double diaphragm System N 143 AN.12 E N 143 AV.12 E N 143 SN.12 E N 143 SV.12 E Operating and Installation Instructions Read and observe these Operating and Installation

More information

Diaphragm Vacuum Pump

Diaphragm Vacuum Pump Operating Instructions Read and observe these Operating Instructions! Diaphragm Vacuum Pump N920 AP.18 N920 AP.29.18 N920 KT.29.18G KNF Neuberger GmbH Alter Weg 3 D-79112 Freiburg Germany Phone +49-(0)7664

More information

Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps in compact design Liquid ring vacuum pumps in compact design LEM 26, LEM 51 Pressure range: Suction volume flow: 33 to 113 mbar 3 to 58 m³/h CONSTRUCTION TYPE SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated

More information

MICRO DIAPHRAGM LIQUID PUMPS DATA SHEET NF 100/1.100 NF 100 / 1.100

MICRO DIAPHRAGM LIQUID PUMPS DATA SHEET NF 100/1.100 NF 100 / 1.100 MICRO DIAPHRAGM LIQUID PUMPS DATA SHEET /1.100 / 1.100 KP.51 DC NF 1.100 KPE KP.27 AA Concept KNF diaphragm liquid pumps are based on the principle of the oscillating displacement pump which is remarkably

More information

Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860

Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860 PROCESS Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860 Single & Twin-Head Designs OEM Installation Models UN860FTI EX UN726.3STI EX UN726.3FTI

More information

Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps in compact design Liquid ring vacuum pumps in compact design, Pressure range: Suction volume flow: 33 to 113 mbar 3 to 58 m³/h CONSTRUCTION TYPE SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated and

More information

DIAPHRAGM PRESSURE CONTROL VALVE FDV 30 / 31, FDV 1.30 / 1.30 FDV 300 / 301, FDV / 1.301

DIAPHRAGM PRESSURE CONTROL VALVE FDV 30 / 31, FDV 1.30 / 1.30 FDV 300 / 301, FDV / 1.301 DIAPHRAGM PRESSURE CONTROL VALVE FDV 30 / 31, FDV 1.30 / 1.30 FDV 300 / 301, FDV 1.300 / 1.301 FDV 31 KP Z A: Pump Accessories KP/KP.51 / KV / KT / TV / TT 30 / 1.30 / 31 / 1.31 / 300 / 1.300 / 301 / 1.301

More information

SCH-27. Diaphragm Pressure Switch. Setting range: mbar to bar. Temperature: max C. Material: stainless steel

SCH-27. Diaphragm Pressure Switch. Setting range: mbar to bar. Temperature: max C. Material: stainless steel Diaphragm Pressure Switch measuring monitoring analysing SCH-27 P3 Setting range: 0.7... 6 mbar to 8... 160 bar Temperature: max. +100 C Material: stainless steel Connection: G ½ male, ½" NPT male, ¼"

More information

Best Practices for Installation of Gaseous Sample Pumps

Best Practices for Installation of Gaseous Sample Pumps Best Practices for Installation of Gaseous Sample Pumps Goal of the Gas Sample Pump Transport a clean, reliable, sample of the process gas to the analyzer, in the safest and easiest way possible, to ensure

More information

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment) Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air Types: PE 200-TE PE 250-TE PE 300-TE Production status: F02 PE 250-TE with compressor control (optional equipment) General Medium

More information

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP This operating instructions contains safety information that if ignored can endanger life or result in serious injury. They are indicated by this icon. Use of this pump with radioactive chemicals is forbidden!

More information

Liquid ring vacuum pumps in compact design

Liquid ring vacuum pumps in compact design Liquid ring vacuum pumps in compact design LEM 25, LEM 5 Pressure range: Suction volume flow: 33 to 113 mbar 4 to 6 m³/h CONSTRUCTION SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated

More information

Offshore // Marine // Subsea Cable solutions that thrive under pressure

Offshore // Marine // Subsea Cable solutions that thrive under pressure Offshore // Marine // Subsea Cable solutions that thrive under pressure Underwater and pressure resistant cables and harnesses for your needs For over 40 years Habia Cable has developed and manufactured

More information

ASB Accumulator Safety Blocks

ASB Accumulator Safety Blocks ASB Accumulator Safety Blocks For working pressures up to 350 bar Catalogue HY07-1241/UK Note: In line with our policy of continuing product improvement, specifications in this catalogue are subject to

More information

h2000 plus HyDROGEN LEAk DETECTOR

h2000 plus HyDROGEN LEAk DETECTOR H2000 plus hydrogen leak detector hydrogen leak detector h2000 plus Fast, easy to use, and durable. Leak testing with Hydrogen tracer gas The Hydrogen Method Detecting leaks using Hydrogen, called the

More information

Auxiliary Valve PRS6 Pressure Reducing Valve. Catalogue HY /UK June 2003

Auxiliary Valve PRS6 Pressure Reducing Valve. Catalogue HY /UK June 2003 Auxiliary Valve Pressure Reducing Valve June 2003 General Subject to alteration without prior notice. The curves and diagrams in this catalogue are typical examples only. While the contents of the catalogue

More information

Liquid ring vacuum pumps single-stage

Liquid ring vacuum pumps single-stage Liquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 Pressure range: Suction volume flow: 150 to 1013 mbar 50 to 270 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum pumps are displacement

More information

Squeegee Unit for MRS Multi-Recovery System

Squeegee Unit for MRS Multi-Recovery System En Operating Instructions Squeegee Unit for MRS Multi-Recovery System Translation of the original operating instructions Squeegee - MRS Table of Contents Safety Recommendations Technical Data - MRS Booth

More information

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in

More information

TECHNOLOGIES. M Series. Positive return metering pumps [API675]

TECHNOLOGIES. M Series. Positive return metering pumps [API675] M Series Positive return metering pumps [API675] Hydraulic double diaphragm metering pump in AISI 316L stainless steel A line of plunger and hydraulic double diaphragm metering pumps designed according

More information

Happiness trends in 24 countries,

Happiness trends in 24 countries, Happiness trends in 4 countries, 1946-006 The following graphs shows the trends in happiness levels found in 4 countries, using comparable data from all available surveys for countries having at least

More information

Solenoid valves VZWF, force pilot operated

Solenoid valves VZWF, force pilot operated Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is

More information

A17W49_MASEM_F_EN MANUAL

A17W49_MASEM_F_EN MANUAL AW9_MASEM_F_EN MANUAL CONTENTS Identification. Manufacturer. Product name. Year of manufacture. Area of use. Declaration of conformity Technical specification. Design. Function. Technical data. Electrical

More information

Optimization of a Proven Technology

Optimization of a Proven Technology Optimization of a Proven Technology Second Generation closed-circuit breathing apparatus Symbiose The new BG 4 closed-circuit breathing apparatus is a symbiosis of reliable Dräger technology and practical

More information

Liquid ring compressors

Liquid ring compressors Liquid ring compressors KPH 85220, KPH 85227 Compression pressures: Suction volume flow: 2 to 7 bar 940 to 1450 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors

More information

CAT-W Iwaki pneumatic drive bellows pumps

CAT-W Iwaki pneumatic drive bellows pumps CAT-W 0051-01 Iwaki pneumatic drive bellows pumps For Ultrapure Chemical Delivery in Semiconductor Processing The F series comprises pneumatic drive bellows pumps designed for use in semiconductor manufacturing

More information

Valvex Valves for Mining Applications

Valvex Valves for Mining Applications Valvex Valves for Mining pplications roven technology The Electronic Drive Systems product group at Voith Turbo GmbH & Co. KG develops and produces explosion-proof Valvex solenoid valves and valve assemblies.

More information

HydroCOM: High energy savings and excellent controllability

HydroCOM: High energy savings and excellent controllability HydroCOM: High energy savings and excellent controllability Almost all applications require efficient capacity control systems Most of them simply waste energy, are slow and inaccurate. HydroCOM, however,

More information

High Pressure Breathing Air Compressors

High Pressure Breathing Air Compressors High Pressure Breathing Air Compressors [ Full variety for different applications] MSA offers a comprehensive range of high pressure breathing air compressors for both the firefighting and diving market,

More information

Liquid ring compressor

Liquid ring compressor Liquid ring compressor KLH 47005, KLH 47105 Compression pressures: Suction volume flow: 2 to 11 bar 56 to 65 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors of

More information

AREA TOTALS OECD Composite Leading Indicators. OECD Total. OECD + Major 6 Non Member Countries. Major Five Asia. Major Seven.

AREA TOTALS OECD Composite Leading Indicators. OECD Total. OECD + Major 6 Non Member Countries. Major Five Asia. Major Seven. Reference series Composite leading indicators OECD Composite Leading Indicators AREA TOTALS 7-03- 19 OECD Total 19 OECD + Major 6 Non Member Countries 19 Major Seven 19 Major Five Asia 19 Euro area 19

More information

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT CAUTION!

More information

BSS 2 Bottle Sampling System. Instruction manual Version 1.8

BSS 2 Bottle Sampling System. Instruction manual Version 1.8 BSS 2 Bottle Sampling System Instruction manual Version 1.8 Serial-No.:... Version-/Rev.-Date : 12.06.2012 Contents 1. General... 3 2. Safety Instructions... 4 3. Extent of Delivery... 5 4. Switch Panel...

More information

Compressed Airline Breathing Apparatus

Compressed Airline Breathing Apparatus Compressed Airline Breathing Apparatus [ The Independence in Breathing] The Complete Range at a Glance Full face mask with lung governed demand valve Light duty airline breathing apparatus Cavair LDA Pressure

More information

SIHI LPH-X - Liquid Ring Compressors

SIHI LPH-X - Liquid Ring Compressors - Liquid Ring Compressors LPH 50523 LPH 60527 Pressure range: Suction volume range: 0.2 to 1.5 bar 260 to 780 m³/h CONSTRUCTION Sterling SIHI liquid ring compressors are displacement compressors with a

More information

MULTI-STAGE VACUUM GENERATORS PVP 12 MX and 25 MX

MULTI-STAGE VACUUM GENERATORS PVP 12 MX and 25 MX MULTI-STAGE VACUUM GENERATORS PVP 12 MX and 25 MX This new range of multiple ejector vacuum generators represents the natural evolution of the PVP 12M and 25M generators. In fact, given the same air consumption

More information

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version 2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version Type 6624 Impulse can be combined with... 10mm width orifice DN 0.8 to 1.2 with pressure range vacuum to 5bar medium separation, for

More information

Applications. What moves your world

Applications. What moves your world Digital Control Proportional Valves Series D92 High-performance pressure control valve with high dynamics and the ability to easily and exactly tune the pressure controller gain The pq-proportional valves

More information

Diaphragm Accumulators

Diaphragm Accumulators Diaphragm Accumulators. DESCRIPTION.. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in HYDAC diaphragm accumulators

More information

Series IRV1000/2000/3000

Series IRV1000/2000/3000 CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one

More information

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic Pharmaceutical SRL Series Oil-less Scroll Air Compressors Research & Development Food & Beverage Chemical Electronic Hitachi Industrial Equipment Product Brochure Hitachi SRL Series scroll compressors

More information

Automatic Control Unit. Cervomatic EDP.2. Type Series Booklet

Automatic Control Unit. Cervomatic EDP.2. Type Series Booklet Automatic Control Unit Cervomatic EDP.2 Type Series Booklet Legal information/copyright Type Series Booklet Cervomatic EDP.2 All rights reserved. The contents provided herein must neither be distributed,

More information

Airless-Spraying Equipment. SuperFinish31. Fully equipped. More power. Innovative QLS technology

Airless-Spraying Equipment. SuperFinish31. Fully equipped. More power. Innovative QLS technology Airless-Spraying Equipment SuperFinish31 Fully equipped More power Innovative QLS technology New technology, fully equipped with even more power. This is the new SuperFinish 31 Airless spraying equipment,

More information

COSMO INSTRUMENTS CO., LTD.

COSMO INSTRUMENTS CO., LTD. Specification Sheet COSMO AIR LEAK TESTER ModelLS-1861 Meets SI Unit Requirement Improved accuracy with the new Master-Preset compensation feature Compensates for environmental changes Improves cycle time

More information

Precise Finish. Fast Results. Easy to Use.

Precise Finish. Fast Results. Easy to Use. trimjet E Precise Finish. Fast Results. Easy to Use. The WINTERSTEIGER trimjet is an automatic edge grinding machine for skis and snowboards. Equipped with disc technology from the ski industry, the trimjet

More information

Medium-sized vessels water connection. White paper

Medium-sized vessels water connection. White paper Medium-sized vessels water connection White paper Flamco B.V. January 2017 Medium-sized vessels water connection In practice you will find expansion vessels with the water connection on bottom, and with

More information

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids HELYON 5 Chemin du Jubin 69570 DARDILLY Tél. +33 (0)4 72 52 16 70 - Fax +33 (0)4 72 52 16 71 R300 Brass high pressure regulator, for compressed air, gas and liquids FEATURES Pressure regulator for inlet

More information

Manual Actuated Boiler Blowdown Valves

Manual Actuated Boiler Blowdown Valves Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. An electric standardized signal of 4 to 20 ma or

More information

Pressure Relief Valve DHV 718

Pressure Relief Valve DHV 718 Advantages frictionless components low maintenance low pressure increase up to fully opened valve constant low vibration controlling hermetically sealed by diaphragm for oscillating pumps for viscous media

More information

DEWATERING PUMP SOLUTIONS. Pneumatic pumps

DEWATERING PUMP SOLUTIONS. Pneumatic pumps DEWATERING PUMP SOLUTIONS Pneumatic pumps PUMP UP YOUR BUSINESS A pneumatic pump is a great choice when failure is not an option. They re easy to use, safe and can handle almost anything you throw at them.

More information

THE POWERFUL LEAK DETECTOR FOR ALL APPLICATIONS IN POWER PLANTS

THE POWERFUL LEAK DETECTOR FOR ALL APPLICATIONS IN POWER PLANTS THE POWERFUL LEAK DETECTOR FOR ALL APPLICATIONS IN POWER PLANTS Use of HeliTest GEN for location of leaks on the steam circuit of a turbine of a working power plant INTRODUCTION Power plant turbines, regardless

More information

SuperFinish 27. Available versions. Accessories. SuperFinish 27 Spraypack. Basic unit. Tip extensions / pole guns. Suction systems.

SuperFinish 27. Available versions. Accessories. SuperFinish 27 Spraypack. Basic unit. Tip extensions / pole guns. Suction systems. Available versions Spraypack Basic unit 0341 051 basic unit on trolley including pressure gauge system + QuickClean suction + 15 m high pressure hose + Airless gun G 12 + Wagner Tip holder with Airless

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

Underwater pressure resistant. cables and harnesses for outboard use

Underwater pressure resistant. cables and harnesses for outboard use Underwater pressure resistant cables and harnesses for outboard use As one of our business focus markets, Habia Cable is committed to the Naval industry. We are a supplier to most major navies around the

More information

SM Models Manual Control

SM Models Manual Control SM Models Manual Control Practical Choice for Solenoid-driven Pumps Models for chemical injection, high-pressure boiler feed, and outgassing fluids. Temperatures ranges (ambient and transferring liquid)

More information

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Pressure relief valve DHV 725 set range: 0,2-10,0 bar Pressure relief valve DHV 75 set range: 0, - 0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level

More information

PVK OPEN LOOP PUMPS. Bulletin E

PVK OPEN LOOP PUMPS. Bulletin E PVK OPEN LOOP PUMPS Bulletin 47025-E Table of Contents Performance Assurance page 3 Features and Benefits page 4-5 Specifications page 6 Pump Controls page 7 Table of Contents Curves Performance page 8

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20

More information

CNG FILLING STATIONS

CNG FILLING STATIONS CNG FILLING STATIONS GAS INLET 3/4 F EXIT CNG TO CAR TANK 5 mt / 16 feet HOSE AND FILLING NOZZLE REMOTE ELECTRIC PANEL THREE-PHASE height 40 cm / 15.7 width 30 cm / 11.8 depth 20 cm / 7.8 EQUIPPED WITH

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

ALPHADYNAMIC has filed with the TUV NORD certification body the documentation certifying

ALPHADYNAMIC has filed with the TUV NORD certification body the documentation certifying ATEX COMPLIANCE ALPHADYNAMIC has filed with the TUV NORD certification body the documentation certifying ATEX compliance pursuant to Directive 94/9/EC for its ranges of ADB BOXER pneumatic diaphragm pumps.

More information

Pressure transmitter PASCAL Ci4

Pressure transmitter PASCAL Ci4 Pressure transmitter PASCAL Ci4 for general application,type Series CI4100 Features Pressure transmitter for the measuring of relative and absolute pressures of gases, vapors and liquids High-resolution

More information

HyDefinition HD4070. Plasma Arc Cutting / Marking System. Product Configuration Manual Revision

HyDefinition HD4070. Plasma Arc Cutting / Marking System. Product Configuration Manual Revision HyDefinition HD4070 Plasma Arc Cutting / Marking System Product Configuration Manual 803770 Revision 1 4070.97 HD4070 Product Configuration Manual (P/N 803770) Revision 1 December, 2002 Hypertherm, Inc.

More information

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar single stage pumps M/5811 Very high induced air capacity % lower air consumption than comparable single stage units No wearing parts Compatible with a wide range of line contaminants llows direct connection

More information

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005 RDK-408D2 Cold Head Technical Manual SHI-APD Cryogenics Inc. 1833 Vultee Street Allentown, PA 18103-4783 U.S.A. Revision A: September 2005 (Reference SHI Manual: December 18, 2003 266404A CD32ZZ-160A)

More information

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Pressure relief valve DHV 716 set range: 0,5-10,0 bar Pressure relief valve DHV 7 set range: 0,5-0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level of

More information

Better to have one OXYLOG 3000

Better to have one OXYLOG 3000 MT-0852-2008 Better to have one OXYLOG 3000 Oxylog 3000 MT-676-2003 MT-1233-2004 MT-0741-2008 Time and time again, Dräger has contributed to major advances in emergency medicine with innovative masterpieces

More information

Dräger PAS AirPack 1 Compressed Air Breathing Apparatus

Dräger PAS AirPack 1 Compressed Air Breathing Apparatus Dräger PAS AirPack 1 Compressed Air Breathing Apparatus Designed using leading technology and materials, Dräger s range of heavy-duty airline apparatus is ideal for use where an extended duration of breathing

More information

Diaphragm Accumulators

Diaphragm Accumulators Diaphragm Accumulators. DESCRIPTION.. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydraulic accumulators for storing

More information

Instruction Manual Contact Pressure Vacuum Gauge

Instruction Manual Contact Pressure Vacuum Gauge MS10 Instruction Manual Contact Pressure Vacuum Gauge Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information

Premium Solutions for Gas and Biogas Handling

Premium Solutions for Gas and Biogas Handling Premium Solutions for Gas and Biogas Handling Blower Solutions for Gas & Biogas Type of gas Applications Application requisites Specific characteristics of the blower unit Premium Solutions for Gas and

More information