Diaphragm-Gas Sampling Pumps with double diaphragm System N 143 AN.12 E N 143 AV.12 E. N 143 SN.12 E N 143 SV.12 E Operating and

Size: px
Start display at page:

Download "Diaphragm-Gas Sampling Pumps with double diaphragm System N 143 AN.12 E N 143 AV.12 E. N 143 SN.12 E N 143 SV.12 E Operating and"

Transcription

1 Diaphragm-Gas Sampling Pumps with double diaphragm System N 143 AN.12 E N 143 AV.12 E N 143 SN.12 E N 143 SV.12 E Operating and Installation Instructions Read and observe these Operating and Installation Instructions! N AN.12 E N AV.12 E N AN.12 E N AV.12 E N SN.12 E N SV.12 E N SN.12 E N SV.12 E KNF Neuberger GmbH Alter Weg 3 D Freiburg Germany Phone +49-(0) Fax +49-(0) info@knf.de Contents Page 1. About this document Use Safety Technical Data Design and function Installation and connection Operation Servicing Troubleshooting Spare parts and accessories Returns Health and safety clearance and decontamination form KNF /16 Translation of original Operating and Installation Instructions, english Keep for future use!

2 About this document Diaphragm Pumps N 143/ About this document 1.1. Using the Operating and Installation Instructions The Operating and Installation Instructions are part of the pump. Pass on the Operating and Installation Instructions to the next owner. Project pumps Customer-specific project pumps (pump models which begin with "PJ" or "PM") may differ from the Operating and Installation Instructions. For project pumps, also observe the agreed upon specifications Symbols and markings Warning A danger warning is located here. WARNING Possible consequences of a failure to observe the warning are specified here. The signal word, e.g. Warning, indicates the danger level. Measures for avoiding the danger and its consequences are specified here. Danger levels Signal word Meaning DANGER WARNING CAUTION warns of immediate danger warns of possible danger warns of a possibly dangerous situation Consequences if not observed Death or serious injuries and/or serious damage are the consequence. Death or serious injuries and/or serious damage are possible. Minor injuries or damage are possible. Tab. 1 Other information and symbols An activity to be carried out (a step) is specified here. 1. The first step of an activity to be carried out is specified here. Additional, consecutively numbered steps follow. This symbol refers to important information. 2 Translation of original Operating and Installation Instructions, english, KNF /16

3 Diaphragm Pumps N 143/ Use Operating parameters and conditions Requirements for transferred medium 2. Use 2.1. Proper use The pumps are exclusively intended for transferring gases and vapors. Owner's responsibility Only install and operate the pumps under the operating parameters and conditions described in chapter 4, Technical data. Protect the compressors with a pressure relief device between the pressure side of the compressor and the first shut-off valve. Only complete pumps may be taken into service. Make sure that the installation location is dry and the pump is protected against rain, splash, hose and drip water. The gas-tightness of the connections between the application pipes and the pump (or the pump connection) must be checked regularly; with leaky connections, there is a danger that hazardous gases or vapors may escape from the pump system. Before using a medium, check whether the medium can be transferred danger-free in the specific application case. Before using a medium, check the compatibility of the materials of the pump head, diaphragm and valves with the medium. Danger of dangerous gas mixtures during operation of the pump if the working diaphragm ruptures: Depending on the medium being pumped, a rupture of the working diaphragm may produce a potentially dangerous mixture when the medium mixes with the air in the innerspace between the working diaphragm and the safety diaphragm. Evacuate the innerspace between the working diaphragm and the safety diaphragm (see position 5 in Fig. 4, p. 12) through the two holes in the pump head. At two-headed pumps this is applicable for both pump heads. KNF recommends monitoring the pressure of the evacuated innerspace between the working diaphragm and the safety diaphragm. Immediately stop the pump if the pressure becomes elevated. Immediately stop the pump if the working diaphragm ruptures. The working diaphragm and the safety diaphragm must be replaced before continuing with operation (see chapter 8, Maintenance). If pressure or flow rate change without apparent reason, immediately switch off the pump and check for damages. Only transfer gases which remain stable under the pressures and temperatures occurring in the pump. Translation of original Operating and Installation Instructions, english, KNF /16 3

4 Use Diaphragm Pumps N 143/ Improper use The pumps may not be operated in an explosive atmosphere. The pumps are not suitable for transferring liquids. The pumps are not suitable for transferring dusts. Pumps designed to create either a vacuum or an overpressure must not be used for these two purposes simultaneously. An overpressure must not be applied to the suction side of the pump. Pumps with three-phase motor are not provided for the operation with frequency converter. 4 Translation of original Operating and Installation Instructions, english, KNF /16

5 Diaphragm Pumps N 143/ Safety 3. Safety Note the safety precautions in chapters 6. Installation and connection, and 7. Operation. Personnel Working in a safetyconscious manner Handling dangerous media Handling combustible media Environmental protection EC Directives / Standards The pumps are built according to the generally recognized rules of technology and in accordance with the occupational safety and accident prevention regulations. Nevertheless, dangers can result during their use which lead to injuries to the user or others, or to damage to the pump or other property. Only use the pumps when they are in a good technical and proper working order, in accordance with their intended use, observing the safety advice within the operating and installation instructions, at all times. Make sure that only trained and instructed personnel or specially trained personnel work on the pumps. This especially applies to assembly, connection and servicing work. Make sure that the personnel has read and understood the operating and installation instructions, and in particular the "Safety" chapter. Observe the accident prevention and safety regulations when performing any work on the pump and during operation. The pump heads heat up during operation avoid contact with them. When transferring dangerous media, observe the safety regulations when handling these media. Be aware that the pumps are not designed to be explosion-proof. Make sure the temperature of the medium is always sufficiently below the ignition temperature of the medium, to avoid ignition or explosion. This also applies for unusual operational situations. Note that the temperature of the medium increases when the pump compresses the medium (compressor operation). Hence, make sure the temperature of the medium is sufficiently below the ignition temperature of the medium, even when it is compressed to the maximum permissible operating pressure of the pump. The maximum permissible operating pressure of the pump is stated in the technical specifications (chapter 4). If necessary, consider any external sources of energy, such as radiation, that may add heat to the medium. In case of doubt, consult the KNF customer service. Store all replacement parts in a protected manner and dispose of them properly in accordance with the applicable environmental protection regulations. Observe the respective national and international regulations. This especially applies to parts contaminated with toxic substances. For the purposes of the Machinery Directive 2006/42/EC, pumps are partly completed machinery, and are therefore to be regarded as not ready for use. Partly completed machinery may not be Translation of original Operating and Installation Instructions, english, KNF /16 5

6 Safety Diaphragm Pumps N 143/ Customer service and repairs commissioned until such time as it has been determined that the machine in which the partly completed machinery is to be assembled is in conformity with the provisions of the Machinery Directive 2006/42/EC. The following essential requirements of Annex I of Directive 2006/42/EC (general principles) are applied and observed: General Principles No. 1 No / / / / / / / / / / / / As these partly completed machinery are OEM-models the power supplies and the equipment for disconnecting and switching-off the partly completed machinery respectively have to be considered when mounting as well as over-current and overload protective gear. In addition a protection against mechanical parts in motion and hot parts, if existing, has to be provided when mounting. The pumps conform to the Directive 2011/65/EU (RoHS2). The following harmonized standards have been used: DIN EN DIN EN /2 DIN EN /3 DIN EN Only have repairs to the pumps carried out by the KNF Customer Service responsible. Use only genuine parts from KNF for servicing work. 6 Translation of original Operating and Installation Instructions, english, KNF /16

7 Diaphragm Pumps N 143/ Technical Data 4. Technical Data Pump materials N 143 AN.12 E N AN.12 E N AN.12 E Assembly Head plate, intermediate plate, intermediate ring Working diaphragm Safety diaphragm Valve plate Retainer plate Conrod disc O-rings Material Aluminium CR NBR CR Stainless Steel Aluminium NBR Tab. 2 N 143 AV.12 E N AV.12 E N AV.12 E Assembly Head plate, intermediate plate, Intermediate ring Working diaphragm Safety diaphragm Valve plate Retainer plate Conrod disc O-rings Material Aluminium FPM FPM FPM Stainless Steel Aluminium FPM Tab. 3 N 143 SN.12 E N SN.12 E N SN.12 E Assembly Head plate, intermediate plate, Intermediate ring Working diaphragm Safety diaphragm Valve plate Retainer plate Conrod disc O-rings Material Stainless Steel Aluminium CR NBR CR Stainless Steel Aluminium NBR Tab. 4 Translation of original Operating and Installation Instructions, english, KNF /16 7

8 Technical Data Diaphragm Pumps N 143/ N 143 SV.12 E N SV.12 E N SV.12 E Assembly Head plate, intermediate plate, Intermediate ring Working diaphragm Safety diaphragm Valve plate Retainer plate Conrod disc O-rings Material Stainless Steel Aluminium FPM FPM FPM Stainless Steel Aluminium FPM Tab. 5 Pneumatic values N 143 AN.12 E N 143 AV.12 E N 143 SN.12 E N 143 SV.12 E Parameter Value Max. permissible operating pressure [bar g] 3.0 Ultimate vacuum [mbar abs.] 100 Delivery rate at atm. pressure [l/min]* 30 Tab. 6 N AN.12 E N AV.12 E N SN.12 E N SV.12 E *Liters in standard state (1,013 mbar) Parameter Value Max. permissible operating pressure [bar g] 3.0 Ultimate vacuum [mbar abs.] 100 Delivery rate at atm. pressure [l/min]* 50 Tab. 7 *Liters in standard state (1,013 mbar) N AN.12 E N AV.12 E N SN.12 E N SV.12 E Parameter Value Max. permissible operating pressure [bar g] - Ultimate vacuum [mbar abs.] 3 Delivery rate at atm. pressure [l/min]* 30 Tab. 8 *Liters in standard state (1,013 mbar) 8 Translation of original Operating and Installation Instructions, english, KNF /16

9 Diaphragm Pumps N 143/ Technical Data Pneumatic Connections Parameter N E and N E N E Hole for pressure monitoring of intermediate space between working diaphragm and safety diaphragm Value Thread size G 1/4 Taper bush type pipe union for pipe OD 10 Thread size G 1/8 Tab. 9 Electrical data Parameter Electrical data Protection class motor Maximum permitted mains voltage fluctuations Value See type plate IP44 +/- 10 % Tab. 10 Thermal-switch The pumps with capacitor motor are fitted as standard with a thermal-switch to protect against overloading. Weight Pump type N 143 AN.12 E N 143 AV.12 E N 143 SN.12 E N 143 SV.12 E N AN.12 E N AV.12 E N SN.12 E N SV.12 E N AN.12 E N AV.12 E N SN.12 E N SV.12 E Weight (kg) approx approx approx approx approx approx Tab. 11 Translation of original Operating and Installation Instructions, english, KNF /16 9

10 Technical Data Diaphragm Pumps N 143/ Other parameters Ambient and media temperature Permissible ambient temperature + 5 C to + 40 C Permissible media temperature + 5 C to + 40 C Gas-tightness Gas-tightness* of pump head/pump heads (leak rate) Other Dimensions N E: L x H x W [mm] Dimensions N E: L x H x W [mm] Dimensions N E: L x H x W [mm] Maximum permissible ambient relative humidity Max. altitude of site [m above sea level] Tab. 12 < 6 x 10-6 mbar l/s** 400 x 223 x x 225 x x 225 x % for temperatures up to 31 C, decreasing linearly to 50 % at 40 C 2000 * Perform a leak test in order to ensure gas-tightness after opening the pump head/pump heads or after exchanging diaphragms and valve plates. ** Values valid for helium leak test. Additional equipment The pump is equipped with a safety diaphragm. Refer to chapter 5 for an explanation of purpose and principle. Refer to chapter 6.4 for notes on assembly and connection. Refer to chapter 7 for notes on operation. 10 Translation of original Operating and Installation Instructions, english, KNF /16

11 Diaphragm Pumps N 143/ Design and function 5. Design and function Design N E 1 Pneumatic outlet (G ¼) 2 Pneumatic inlet (G ¼) 3 Terminal box (electrical connection) 4 Motor 5,6 Screw plug of hole for pressure monitoring the diaphragm intermediate space 7 Fan cover Fig. 1: Double diaphragm pump N E Design N E 1 Pneumatic inlet (Tube OD 10) 2 Pneumatic outlet (Tube OD 10) 3 Pneumatic head connection suction side 4 Screw plug of hole for pressure monitoring the diaphragm intermediate space of head 1 (2x) 5 Screw plug of hole for pressure monitoring the diaphragm intermediate space of head 2 (2x) 6 Pneumatic head connection pressure side 7 Fan cover 8 Union nut 9 Motor Fig. 2: Double diaphragm pump N E Translation of original Operating and Installation Instructions, english, KNF /16 11

12 Design and function Diaphragm Pumps N 143/ Pneumatic outlet (G ¼) 2 Pneumatic inlet (G ¼) 3 Pneumatic head connection 4 Motor 5 Screw plug of hole for pressure monitoring the diaphragm intermediate space of head 2 (2x) 6 Screw plug of hole for pressure monitoring the diaphragm intermediate space of head 1 (2x) 7 Fan cover 8 Union nut Design N E Fig. 3: Double diaphragm pump N E 1 Outlet valve 2 Inlet valve 3 Transfer chamber 4 Working diaphragm 5 Innerspace 6 Hole for pressure monitoring the innerspace (5) 7 Safety diaphragm 8 Eccentric 9 Connecting rod 10 Pump drive Function Double diaphragm pump Fig. 4: Pump head Double diaphragm pumps transfer, compress (depending on pump version) and evacuate gases and vapors. The elastic working diaphragm (4) is moved up and down by the eccentric (8) and the connecting rod (9). In the downward stroke it aspirates the gas to be transferred via the inlet valve (2). In the upward stroke, the working diaphragm presses the medium out of the pump head via the outlet valve (1). The transfer chamber (3) is hermetically separated from the pump drive (10) by the working diaphragm and a safety diaphragm. A second diaphragm (safety diaphragm (7)) is located underneath the working diaphragm. This second diaphragm is under less 12 Translation of original Operating and Installation Instructions, english, KNF /16

13 Diaphragm Pumps N 143/ Design and function mechanical stress when the pump is operating. lf gas should leak at the working diaphragm, it will still remain inside the pump space. The innerspace (5) between both diaphragms can be pressure monitored so that any damage to the working diaphragm will be noted immediately. For this purpose, the pump head has two holes (6). Translation of original Operating and Installation Instructions, english, KNF /16 13

14 Installation and connection Diaphragm Pumps N 143/ Installation and connection Only install the pumps under the operating parameters and conditions described in chapter 4, Technical data. Observe the safety precautions (see chapter 3). Mounting dimensions 6.1. Installation of the pump Before installation, store the pump at the installation location to bring it up to ambient temperature. See fig. 5 (pump series N E) and fig. 6 (pump series N E and N E) for the mounting dimensions. Fig. 5: Mounting dimensions pump series N E (All dimensional tolerances conform to DIN ISO , Tolerance Class V) Fig. 6: Mounting dimensions pump series N E and N E; shown without pneumatic connections (All dimensional tolerances conform to DIN ISO , Tolerance Class V) Cooling air supply Install the pump so that the motor fan can intake sufficient cooling air. 14 Translation of original Operating and Installation Instructions, english, KNF /16

15 Diaphragm Pumps N 143/ Installation and connection Installation location Disengaging Make sure that the installation location is dry and the pump is protected against rain, splash, hose and drip water. The IP protection class of the pump motor is indicated on the type plate. Install the pump at the highest point in the system to prevent condensate from collecting in the pump head. Protect the pump from dust. Protect the pump from vibrations and jolts. KNF recommends mechanically disengaging the pump from the piping system. This can be achieved with flexible tubing or pipes, for example. This will avoid transferring to the system any pump oscillations that may arise Electrical connection Extreme danger from electrical shock DANGER Only have the pump connected by an authorized specialist. Only have the pump connected when the power supply is disconnected. When connecting the device to a power source, the relevant standards, directives, regulations, and technical standards must be observed. In the electrical installation, arrangements (complying with EN ) must be made for disconnecting the pump motor from the electrical supply. The motors of the pump must be protected according to EN (protection against excess current, or overloading). For operating current see type plate. It is recommended that an additional Emergency Stop switch is installed. The pump must be installed so that contact with live parts (electrical connection) is impossible. Connecting pump 1. Compare the supply data with the data on the motor-plate. For operating current see type plate. The voltage must not vary by more than + 10% and - 10% from that shown on the type-plate. 2. Open terminal box cover. 3. All pumps except versions with 3 phase motor: Connect the mains cables to the connections L1 and N of the pump motor. Translation of original Operating and Installation Instructions, english, KNF /16 15

16 Installation and connection Diaphragm Pumps N 143/ Connection of pumps with 3 phase motor according to figs. 7 or 8. Fig. 7: Y-Connection (high voltage) Fig. 8: -Connection (low voltage) 5. Connect the earth (ground) wire to the motor. 6. Close the terminal cover box. Connected components Pressure relief device Pump exhaust 6.3. Pneumatic connection Only connect components to the pump which are designed for the pneumatic data of the pump (see chapter 4, Technical data). Protect the compressors with a pressure relief device between the pressure side of the compressor and the first shut-off valve. If the pump is used as a vacuum pump, safely discharge the pump exhaust at the pump s pneumatic outlet. Connecting pump A marking on the pump head shows the direction of flow. 1. Remove the protective plugs from the hose connection threads. 2. Connect the suction line and pressure line (see chapter 4, table 9 for the mounting dimensions). 3. Lay the suction and pressure line at a downward angle to prevent condensate from running into the pump. 16 Translation of original Operating and Installation Instructions, english, KNF /16

17 Diaphragm Pumps N 143/ Installation and connection 6.4. Evacuate diaphragm s innerspace and install monitoring device Danger of dangerous gas mixtures during operation of the pump if the working diaphragm ruptures. WARNING Depending on the medium being pumped, a rupture of the working diaphragm may produce a potentially dangerous mixture when the medium mixes with the air in the innerspace between the working diaphragm and the safety diaphragm. Evacuate the innerspace between the working diaphragm and the safety diaphragm (see position 5 in Fig. 4, p. 12) through the two holes in the pump head (thread size G1/8). KNF recommends monitoring the pressure of the evacuated innerspace between the working diaphragm and the safety diaphragm. Immediately stop the pump if the pressure becomes elevated. Immediately stop the pump if the working diaphragm ruptures. The working diaphragm and the safety diaphragm must be replaced before continuing with operation (see chapter 8, Maintenance). Translation of original Operating and Installation Instructions, english, KNF /16 17

18 Operation Diaphragm Pumps N 143/ Operation Only operate the pumps under the operating parameters and conditions described in chapter 4, Technical data. Make sure the pumps are used properly (see chapter 2.1). Make sure the pumps are not used improperly (see chapter 2.2). Observe the safety precautions (see chapter 3). The pumps are intended for installation. Before putting them into service it must be established that machinery or equipment in which they are installed meets the relevant regulations. Hazard of the pump head bursting due to excessive pressure increase WARNING Do not exceed max. permissible operating pressure (see chapter 4, Technical data). Monitor pressure during operation. If the pressure exceeds the maximum permissible operating pressure, immediately switch off pump and eliminate fault (see chapter 9. Troubleshooting). Only throttle or regulate the air or gas quantity in the suction line to prevent the maximum permissible operating pressure from being exceeded. If the air or gas quantity in the pressure line is throttled or regulated, make sure that the maximum permissible operating pressure is not exceeded. Ensure that the pump outlet is not closed or constricted. Excessive pressure (with all of the related hazards) can be prevented by placing a bypass line with a pressure-relief valve between the pressure and suctions sides of the pump. For further information, contact our technical adviser (see front page for telephone number). 18 Translation of original Operating and Installation Instructions, english, KNF /16

19 Diaphragm Pumps N 143/ Operation Dangerous gas mixtures may form if the working diaphragm ruptures DANGER If the working diaphragm ruptures, the medium will mix with the air located in the innerspace between the working diaphragm and the safety diaphragm. If the working diaphragm ruptures, stop the pump immediately. By monitoring the innerspace between the working diaphragm and the safety diaphragm, rupture of the working diaphragm can be detected on the basis of a change in pressure in the innerspace. Even if the pressure or flow rate of the pump changes without any apparent cause, this too can mean that the working diaphragm is ruptured. The working diaphragm and the safety diaphragm must be replaced before continuing with operation (see chapter 8, Maintenance). Automatic starting can cause personal injury and pump damage WARNING When the operation of the pump is interrupted by the thermal switch, the pump will restart automatically after cooling down. Take all necessary care to prevent this leading to a dangerous situation. Pump standstill Vapors as media With the pump at a standstill, open pressure and suction lines to normal atmospheric pressure. The pump may not start up against pressure or vacuum during switch-on. This also applies in operation following a brief power failure. If a pump starts against pressure or vacuum, it may block. This activates the thermal switch, and the pump switches off. Make sure that normal atmospheric pressure is present in the lines during switch-on. The life of the diaphragm is prolonged if the formation of condensate is avoided. Therefore the following precautions should be taken: Run the pump for a few minutes to warm it up before handling saturated or nearly saturated vapours. KNF recommends: When transferring aggressive media, flush the pump prior to switch-off (see chapter 8.2.1) to increase the service life of the diaphragm. Translation of original Operating and Installation Instructions, english, KNF /16 19

20 Servicing Diaphragm Pumps N 143/ Servicing 8.1. Servicing schedule Component Servicing interval Pump - Regular inspection for external damage or leaks Tube connection - Regular inspection for external damage or leaks Working diaphragm, safety diaphragm and valve plate Tab Cleaning Flushing pump - Replace if the pressure in innerspace (evacuated) between the working diaphragm and the safety diaphragm decreases (working diaphragm has broken) - Replace if pump's pressure or flow rate change without apparent reason - Replace at the latest, when pump output decreases KNF recommends: When transferring aggressive media, flush the pump under atmospheric conditions some minutes with air (or, if necessary for safety reasons, with an inert gas) prior to switch-off to increase the service life of the diaphragm Cleaning pump Only use solvents for cleaning if the head materials cannot be attacked (check the resistance of the material). If compressed air is available, blow out the components Replacing working diaphragm, safety diaphragm and valve plate Conditions Motor disconnected from mains and de-energized Pump clean and free of dangerous substances Tubes/pipes removed from pump s pneumatic inlet and outlet Information on procedure WARNING There is the danger that hazardous gas mixtures will form and that the pumped media will leak from the pump while the pump is in operation, if the safety diaphragm is not replaced at the same time as the working diaphragm. Always replace the safety diaphragm at the same time the working diaphragm is replaced. Always replace working diaphragm and safety diaphragm together to maintain performance and safety of the pump. 20 Translation of original Operating and Installation Instructions, english, KNF /16

21 Diaphragm Pumps N 143/ Servicing With multi-head pumps, parts of the individual pump heads can be confused. Replace working diaphragm, safety diaphragm and valve plate of the individual pump heads consecutively. Health hazard due to dangerous substances in the pump! WARNING Depending on the substance transferred, caustic burns or poisoning are possible. Wear protective clothing if necessary, e.g. protective gloves. Clean pump with suitable measures. Spare parts Spare part* Position** Quantity Safety diaphragm (S) 1 (per pump head) Working diaphragm (L) 1 (per pump head) O-Ring (F, H, P) 3 (per pump head) O-Ring (R) 1 (per pump head) O-Ring (T) 1 (per pump head) Valve plate (G) 1 (per pump head) Tab. 14 * according to spare parts list, chapter 10 ** According to Fig. 9. Tools and material Quantity Tools/Material* 1 Allen key 3 1 Allen key 4 1 Allen key 5 1 Screwdriver blade width 5.5 mm 1 Adjustable pin-wrench for two-hole nuts, pin dia. 4 mm, length of wrench ca. 160 mm (available as wrench for retainer plate, a KNF accessory, see chapter 10) 8 Retaining clips for assembling of intermediate ring, intermediate plate and head plate (see Assembling, steps 4, 10 and 13) 1 Felt-tip pen Tab. 15 * according to accessories list, chapter 10 Translation of original Operating and Installation Instructions, english, KNF /16 21

22 Servicing Diaphragm Pumps N 143/ A Housing B Intermediate ring C Intermediate plate D Head plate E Hexagon socket head cap screw F O-ring G Valve plate H O-ring I Retainer plate K Hexagon socket head cap screw L Working diaphragm M Hexagon socket head cap screw N Diaphragm support P O-ring R O-ring S Safety diaphragm T O-ring Z Dowel pin/roll pin Fig. 9: Pump parts The following item numbers refer to Fig. 9, unless otherwise indicated. Disassembling 1. Take the steps necessary to gain access to the motor cooling fan: Undo the screws that hold the fan cover. For one-headed pumps: Fig. 1/7, p. 11; for two-headed pumps: Fig. 2/7, p. 11 or Fig. 3/7, p. 12 and remove the fan cover. 22 Translation of original Operating and Installation Instructions, english, KNF /16

23 Diaphragm Pumps N 143/ Servicing 2. Only for two-headed pumps. Remove the pneumatic connection (.3 models), or connections (.1.2 models) between the pump heads, loosen the union nuts (Fig. 1/8, p. 11 or Fig. 2/8, p. 11 or Fig. 3/8, p. 12) to do so. 3. Mark the position of head plate (D), intermediate plate (C), intermediate ring (B) and housing (A) relative to each other by a drawing line with a felt-tip pen. This helps avoid incorrect assembly later. 4. Undo the six hexagon socket head cap screws (E); lift off head plate (D) and intermediate plate (C) with valve plate (G); remove valve plate from intermediate plate. 5. Remove the O-ring (F) from the head plate (D); remove the O- ring (H) from the intermediate plate. 6. To undo the retainer plate (J), use the wrench for retainer plate to turn it anti-clockwise; remove retainer plate and working diaphragm (L). If the retainer plate cannot be loosened, because the diaphragm support (N) turns with it, carry out step 7 first. In that case clamp the diaphragm support to loosen the retainer plate. 7. Undo the six hexagon socket head cap screws (M); remove intermediate ring (B). 8. Remove the O-ring (P) from the intermediate ring (B). 9. Undo the hexagon socket head cap screw (K); remove the diaphragm support (N). 10. Remove the O-rings (R) and (T) from the diaphragm support (N). 11. Remove safety diaphragm (S). 12. Inspect all parts for dirt and clean them if necessary. Assembling 1. Press the beaded edge of the new safety diaphragm (S) into the groove in the diaphragm support (N). 2. Fit a new O-ring (T) in the shaft of the diaphragm support (N). 3. Push the diaphragm support (N) into the connecting rod and secure it with head cap screw (K). 4. Fit the new O-ring (P) in intermediate ring (B); secure the O- ring with retaining clips so that it cannot fall out during assembly. 5. Make certain that the outer edge of safety diaphragm (S) is seated on the housing (A); now place intermediate ring (B) on the housing (A) according to the marks made previously; tighten the screws (M) lightly. 6. Now remove the retaining clips, and tighten the screws (M) diagonally hand-tight. Translation of original Operating and Installation Instructions, english, KNF /16 23

24 Servicing Diaphragm Pumps N 143/ Fit the new O-Ring (R) in the diaphragm support (N). 8. Turn the fan until the connecting rod is in mid-stroke; place the new working diaphragm (L) on the intermediate ring (B) and diaphragm support (N). 9. Place the retainer plate (J) on working diaphragm; to tighten the retainer plate, use the wrench for retainer plate. 10. Fit the new O-ring (H) in the intermediate plate (C); secure the O-ring with retaining clips, so that it cannot fall out during assembly. 11. Place intermediate plate (C) on intermediate ring (B) according to the mark made previously (at the same time, keep the diaphragm in its midposition by holding the motor fan). 12. Fit a new valve plate (G) in the recess in the intermediate plate (C). A dowel pin/roll pin (Z) determines the correct orientation of the intermediate plate. 13. Fit a new O-ring (F) in the diaphragm head (D); secure the O- ring with retaining clips, so that it cannot fall out during assembly. 14. Place head plate (D) on intermediate plate (C) in the position given by the dowel pin/roll pin and the mark made previously. 15. Tighten the hexagon socket head cap screws (E) lightly. 16. Now remove the clips from intermediate plate (C) and diaphragm head (D), and tighten the screws (E) uniformly and diagonally (hand-tight). 17. Turn the fan to check that the pump rotates freely. 18. For two-headed pumps: Carry out steps 3. to 9.of disassembling as well as of assembling for the second pump head. 19. For two-headed pumps: Remount the pneumatic connection(s) between the pump heads. 20. Remount fan cover. For one-headed pumps: Fig. 1/7, p. 11; for two-headed pumps: Fig. 2/7, p. 11 or Fig. 3/7, p Check and ensure the gas-tightness of the pump head/pump heads and the tubing: WARNING Before putting the pump into operation again, check and ensure the gas-tightness of the pump head and the tubing. 24 Translation of original Operating and Installation Instructions, english, KNF /16

25 Diaphragm Pumps N 143/ Troubleshooting 9. Troubleshooting Extreme danger from electrical shock! DANGER Disconnect the pump power supply before working on the pump. Make sure the pump is de-energized and secure. Check the pump (see Tab. 16 and 17). Pump does not transfer Cause Pump is not connected with the power source. No voltage in the power source Thermal switch has operated following to over-heating. Connections or lines blocked. External valve is closed or filter is clogged. Condensate has collected in pump head. Working diaphragm or valve plate are worn. Fault remedy Connect pump with the power source. Check room fuse and switch on if necessary. Disconnect pump from mains. Allow pump to cool. Trace cause of over-heating and eliminate it. Check connections and lines. Remove blockage. Check external valves and filters. Detach the condensate source from the pump. Flush the pump under atmospheric conditions some minutes with air (if necessary for safety reasons: with an inert gas). Replace working diaphragm, safety diaphragm andvalve plate (see chapter 8.3). Tab. 16 Flow rate, pressure or vacuum too low The pump does not achieve the output specified in the Technical data or the data sheet. Cause Fault remedy Working diaphragm has broken. Immediately shut down pump. Check whether the pressure in innerspace (evacuated) between working diaphragm and safety diaphragm has elevated. If the pressure has elevated, replace working diaphragm and safety diaphragm (see chapter 8) before further operating the pump. Condensate has collected in pump head. There is gauge pressure on pressure side and at the same time vacuum or a pressure above atmospheric pressure on suction side. Pneumatic lines or connection parts have an insufficient cross section. Detach the condensate source from the pump. Flush the pump under atmospheric conditions some minutes with air (if necessary for safety reasons: with an inert gas). Change the pressure conditions. Disconnect pump from system to determine output values. Eliminate throttling (e.g. valve) if necessary. Use lines or connection parts with larger cross section if necessary. Translation of original Operating and Installation Instructions, english, KNF /16 25

26 Troubleshooting Diaphragm Pumps N 143/ Flow rate, pressure or vacuum too low The pump does not achieve the output specified in the Technical data or the data sheet. Cause Leaks occur on connections, lines or pump head. Connections or lines completely or partially jammed. Head parts are soiled. Working diaphragm or valve plate is worn. Fault remedy Eliminate leaks. Check connections and lines. Remove the jamming parts and particles. Clean head components. Replace working diaphragm, safety diaphragm and valve plate(see chapter 8.3). Tab. 17 Fault cannot be rectified If you are unable to determine any of the specified causes, send the pump to KNF Customer Service (see last page for the address). 1. Flush the pump under atmospheric conditions some minutes with air (if necessary for safety reasons: with an inert gas) to free the pump head of dangerous or aggressive gases (see chapter 8.2.1). 2. Clean the pump (see chapter 8.2.2). 3. Send the pump, together with completed Health and Safety Clearance and Decontamination Form (Chapter 12), to KNF stating the nature of the transferred medium. 26 Translation of original Operating and Installation Instructions, english, KNF /16

27 Diaphragm Pumps N 143/ Spare parts and accessories 10. Spare parts and accessories Spare Parts N 143 AN.12 E N AN.12 E N AN.12 E N 143 SN.12 E N SN.12 E N SN.12 E Spare part Position* Order No. Working diaphragm (L) Safety diaphragm (S) Valve plate (G) O-ring (F, H, P) O-ring (R) O-ring (T) Tab. 18 *according to Fig. 9 N 143 AV.12 E N AV.12 E N AV.12 E N 143 SV.12 E N AV.12 E N AV.12 E Spare part Position* Order No. Working diaphragm (L) Safety diaphragm (S) Valve plate (G) O-ring (F, H, P) O-ring (R) O-ring (T) Tab. 19 * according to Fig. 9 Accessories Accessories Order No. Wrench for retainer plate Tab. 20 Translation of original Operating and Installation Instructions, english, KNF /16 27

28 Returns Diaphragm Pumps N 143/ Returns Pumps and systems used in laboratories and process-based industries are exposed to a wide variety of conditions. This means that the components contacting pumped media could become contaminated by toxic, radioactive, or otherwise hazardous substances. For this reason, customers who send any pumps or systems back to KNF must submit a Health and safety clearance and decontamination form in order to avoid a hazardous situation for KNF employees. This Health and safety clearance and decontamination form provides the following information, among other things: physiological safety whether medium-contacting parts have been cleaned whether the equipment has been decontaminated media that have been pumped or used To ensure worker safety, work may not be started on pumps or systems without a signed Health and safety clearance and decontamination form. For optimal processing of a return, a copy of this declaration should be sent in advance via , regular mail, or fax to KNF Customer Service (refer to final page for address). In order to avoid endangering employees who open the shipment's packaging, despite any residual hazards, the original version of the Health and safety clearance and decontamination form must accompany the delivery receipt on the outside of the packing. The template for the Health and safety clearance and decontamination form is included with these operating instructions and may also be downloaded from the KNF website. The customer must specify the device type(s) and serial number(s) in the Health and safety clearance and decontamination form in order to provide for the unambiguous assignment of the Declaration to the device that is sent to KNF. In addition to the customer's declaration of physiological safety, information about operating conditions and the customer's application are also of importance to ensure that the return shipment is handled appropriately. Therefore, the Health and safety clearance and decontamination form requests this information as well. 28 Translation of original Operating and Installation Instructions, english, KNF /16

29 Health and safety clearance and decontamination form Diaphragm Pumps N 143/ Health and safety clearance and decontamination form 29 Translation of original Operating and Installation Instructions, english, KNF /16

30

31

32 KNF worldwide Find your local KNF partner on

Diaphragm Vacuum Pumps and Compressors

Diaphragm Vacuum Pumps and Compressors Diaphragm Vacuum Pumps and Compressors N 022 ANE N 026 ANE N 026.1 ANE N 026.2 ANE N 026.3 ANE N 022 AN.9 E N 026 AN.9 E N 026.1 ATE N 026.2 ATE N 026.3 ATE N 022 ATE N 026 ATE N 026.1 AVE N 026.2 AVE

More information

Diaphragm Vacuum Pump

Diaphragm Vacuum Pump Operating Instructions Read and observe these Operating Instructions! Diaphragm Vacuum Pump N920 AP.18 N920 AP.29.18 N920 KT.29.18G KNF Neuberger GmbH Alter Weg 3 D-79112 Freiburg Germany Phone +49-(0)7664

More information

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 037 N 940.5 APE as AC version in IP 54 N 940.5 APE-W with multi-voltage power supply input (As an option adjustable with potentiometer or by external

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 2400 N 2400.15 ST.9 E Concept The diaphragm pumps from KNF arebased on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 143 N 143 SP.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central

More information

DIAPHRAGM GAS SAMPLING PUMPS

DIAPHRAGM GAS SAMPLING PUMPS DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET E 059 N 0150 AP.9E N 0150.3 AP.9E N 0150 SP.12E Double diaphragm pump Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm,

More information

Diaphragm-Gas Sampling Pumps with double diaphragm System N 0150 AN.12 E N 0150 ST.12 E N AN.12 E N ST.12 E

Diaphragm-Gas Sampling Pumps with double diaphragm System N 0150 AN.12 E N 0150 ST.12 E N AN.12 E N ST.12 E Operating and Installation Instructions Read and observe these Operating and Installation Instructions! Diaphragm-Gas Sampling Pumps with double diaphragm System N 0150 AN.12 E N 0150 ST.12 E N 0150.1.2

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET N 186 N 186.1.2 ST.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down

More information

MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 010 N 89 KNDC N 811 KNE N 814 KNE Concept The mini diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge,

More information

DIAPHRAGM PRESSURE CONTROL VALVE FDV 30 / 31, FDV 1.30 / 1.30 FDV 300 / 301, FDV / 1.301

DIAPHRAGM PRESSURE CONTROL VALVE FDV 30 / 31, FDV 1.30 / 1.30 FDV 300 / 301, FDV / 1.301 DIAPHRAGM PRESSURE CONTROL VALVE FDV 30 / 31, FDV 1.30 / 1.30 FDV 300 / 301, FDV 1.300 / 1.301 FDV 31 KP Z A: Pump Accessories KP/KP.51 / KV / KT / TV / TT 30 / 1.30 / 31 / 1.31 / 300 / 1.300 / 301 / 1.301

More information

MINI DIAPHRAGM VACUUM PUMPS

MINI DIAPHRAGM VACUUM PUMPS MINI DIAPHRAGM VACUUM PUMPS DATA SHEET E 024 N 815 KNE N 828 KNDC-B N 838 KNDC Concept The mini diaphragm gas sampling pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its

More information

MICRO DIAPHRAGM GAS PUMPS

MICRO DIAPHRAGM GAS PUMPS MICRO DIAPHRAGM GAS PUMPS DATA SHEET E 5 NMP 83 KNE NMP 85 KNDC NMP 85.1.2 KNDC-B Concept The micro diaphragm gas pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge,

More information

MICRO DIAPHRAGM GAS PUMPS

MICRO DIAPHRAGM GAS PUMPS MICRO DIAPHRAGM GAS PUMPS DATA SHEET E 5 NMP83KNE NMP85KPDC NMP85.1.2KPDC-B Concept The micro diaphragm gas pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge, moves

More information

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator Self-operated Pressure Regulators Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Type 2357-31 with non-return unit at port C Ports A and B with soldering

More information

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN Type 3709 Pneumatic Lock-up Valve Translation of original instructions Mounting and Operating Instructions EB 8391 EN Edition July 2017 Note on these mounting and operating instructions These mounting

More information

Operating Manual VSA100A. tina29e1 ( )

Operating Manual VSA100A. tina29e1 ( ) Operating Manual Incl. EU Declaration of Conformity Vacuum Switch VSA100A tina29e1 (2017-05) 1 Product Identification In all communications with INFICON, please specify the information on the product nameplate.

More information

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar EN - english Instructions for installation and operation Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar Dear customer, Thank you for deciding in favour of the METPOINT

More information

Type BBS-03, BBS-05, BBS-06, BBS-25

Type BBS-03, BBS-05, BBS-06, BBS-25 Type BBS-03, BBS-05, BBS-06, BBS-25 Sterile connection elements Sterile Verbindungselemente Raccords union stériles Operating Instructions Bedienungsanleitung Manuel d utilisation 1. THE OPERATING INSTRUCTIONS

More information

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2 Self-operated Pressure Regulator Pressure Reducing Valve Type M 44-2 Type M 44-2, connection G 1 4, K VS = 0.15 Type M 44-2, connection G 1, K VS = 6 Fig. 1 Type M 44-2 Pressure Reducing Valve Mounting

More information

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST OIL-LESS TYPE IMPORTANT: PLEASE READ CAREFULLY BEFORE STARTING OPERATIONS. THE CONTENTS ARE FOR GENERAL INFORMATION OF ALL THE SIMILAR MODELS. Record

More information

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies Type 2000 INOX 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies Quickstart English Deutsch Français Contents 1 QUICKSTART... 2 2 CONTACT ADDRESS... 2 3 INTENDED USE...

More information

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques.

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

Instruction Manual Contact Pressure Vacuum Gauge

Instruction Manual Contact Pressure Vacuum Gauge MS10 Instruction Manual Contact Pressure Vacuum Gauge Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1. 2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or

More information

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14 15 Elster GmbH Edition 7.15 Translation from the German 519 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve for gas VG VG 15/1 Contents Solenoid valve for gas

More information

444C DUAL PERFORMANCE VALUE PACK

444C DUAL PERFORMANCE VALUE PACK (Chrome) PART NO. 44432 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL

More information

GAS SAMPLING PUMPS WITH KNF DOUBLE DIAPHRAGM SYSTEM

GAS SAMPLING PUMPS WITH KNF DOUBLE DIAPHRAGM SYSTEM GAS SAMPLING PUMPS WITH KNF DOUBLE DIAPHRAGM SYSTEM DATA SHEET E065 Cutaway - Double diaphragm pump Concept The Diaphragm Vacuum Pumps from KNF are based on a simple principal - an elastic diaphragm, fixed

More information

Siphon vessel / Priming aid

Siphon vessel / Priming aid Manufacturer: sera GmbH sera-straße 1 34376 Immenhausen Germany Tel.: +49 5673 999-00 Fax: +49 5673 999-01 info@sera-web.com Keep the operating manual for future use! Record the exact type and serial number

More information

Type /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Type /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 3/2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the right to make technical changes without notice.

More information

Pressure relief valve

Pressure relief valve Pressure relief valve Operating manual Series DHV 712 R Version BA-2016.01.19 EN Print-No. 300 472 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 16 N 35 ANE with IP 2 motor Concept The diaphragm pumps from KNF are based on a simple principal - an elastic diaphragm, ixed on its edge, moves up and

More information

Operating and maintenance manual Filter and reducing station Series / 1.0

Operating and maintenance manual Filter and reducing station Series / 1.0 Operating and maintenance manual Filter and reducing station Series 961 04.2017 / 1.0 Original instructions ARCA Regler GmbH. All rights reserved. Cover picture background: Freepik.com ARCA Regler GmbH

More information

Pressure relief valve

Pressure relief valve Pressure relief valve Operating manual Series DHV 718 Version BA-2016.01.11 EN Print-No. 300 524 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0

More information

MP-F05, MP-F05/R, MP-F10, MP-F10/R

MP-F05, MP-F05/R, MP-F10, MP-F10/R Bellows pump series MP -F MP-F05, MP-F05/R, MP-F10, MP-F10/R Instruction Manual Version 1.04.00 Dear customer, Thank you for buying our product. In this manual you will find all necessary information about

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0 Operating Manual LTIA5E Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0 Contents 1. Safety Instructions 2. Conformity to standards 3. Technical data

More information

Diaphragm relief valve

Diaphragm relief valve Product: Diaphragm relief valve Type: 620.10 622.10 623.10 624.10 625.10 626.10 627.10 Please state here the exact type and serial number of your diaphragm relief valve. (can be read off the type plate

More information

Installation & Operation Manual Proven Quality since 1892

Installation & Operation Manual Proven Quality since 1892 Content 1. ERIKS operating companies 2. Product description 3. Requirements for maintenance staff 4. Transport and storage 5. Function 6. Application 7. Installation 8. Maintenance 9. Service and repair

More information

PSG 901. Pressure Switch for Gas. elektrogas.com EE141-07/12

PSG 901. Pressure Switch for Gas. elektrogas.com EE141-07/12 PSG 901 Pressure Switch for Gas elektrogas.com EE141-07/12 PSG 901 Pressure Switch for Gas (EN1854) Contents Description... 2 Features... 2 Functioning and application... 3 Technical specifications...

More information

Portable Oil Lube Air Compressors

Portable Oil Lube Air Compressors Portable Oil Lube Air Compressors 8003631 8003632 0410149 8018968 8018940 Owner s Manual Read and understand operating instructions before use Safety definitions The information listed below should be

More information

Pressure maintenance valve SDV-P / SDV-P-E

Pressure maintenance valve SDV-P / SDV-P-E Translation of the original manual Pressure maintenance valve SDV-P / SDV-P-E Assembly and Operating Manual Superior Clamping and Gripping Imprint Imprint Copyright: This manual remains the copyrighted

More information

Diaphragm Pressure Keeping Valve

Diaphragm Pressure Keeping Valve Product: Diaphragm pressure keeping valve Type: 620.D 622.D 623.D 624.D 625.D 626.D 627.D Please state here the exact type and serial number of your diaphragm pressure keeping valve. (can be read off the

More information

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289 3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for

More information

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14 2 Elster GmbH Edition. Translation from the German 22 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve for gas G / G Contents Solenoid valve for gas G / G....

More information

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity Type 4708-45 Supply Pressure Regulator with increased air capacity Translation of original instructions Mounting and Operating Instructions EB 8546-1 EN Edition March 2016 Note on these mounting and operating

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET N 186 N 186.1.2 ST.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down

More information

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SUPPLIMENT TO eom IMPORTANT READ THIS MANUAL BEFORE PRODUCT INSTALLATION, OPERATION, INSPECTION & MAINTENANCE Tougher and more rigid guidelines are being established

More information

LRS(H)4 Pressure-Reducing Regulator User Manual

LRS(H)4 Pressure-Reducing Regulator User Manual LRS(H)4 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be considered

More information

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN Type 4708-45 Pressure Regulator for increased air capacity Fig. 1: Type 4708-45 Pressure Regulator Mounting and Operating Instructions EB 8546-1 EN Edition March 2010 Definition of the signal words used

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator. PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

400C & 450C DUAL PERFORMANCE VALUE PACKS

400C & 450C DUAL PERFORMANCE VALUE PACKS (Chrome) PART NO. 40013 (Silver) PART NO. 45012 (Chrome) PART NO. 45013 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before

More information

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26 OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26 Made For: Spitwater Australia Pty Ltd 953 Metry St North Albury, NSW, Australia WARNING: FAILURE TO FOLLOW OPERATING, SAFETY AND MAINTENANCE

More information

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25 Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating

More information

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Model PSI Compressor with 3-Gallon Air Tank 12VDC Model 6350 150 PSI Compressor with 3-Gallon Air Tank 12VDC IMPORTANT: It is essential that you and any other operator of this product read and understandd the contents of this manual before installing

More information

DIAPHRAGM GAS SAMPLING PUMPS

DIAPHRAGM GAS SAMPLING PUMPS DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 0150 N 0150 SP.9 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central point

More information

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL 00, 0, 000 00, 000, 00 A. TECHNICAL INFORMATION Model 00 Inlet/Outlet " Air Inlet /" 0 / 000 /" /" 00 /" /" 000 /" /" 00 /" /" Flow Rate GPM/ 0LPM GPM/ 0LPM GPM/ LPM GPM/ LPM GPM/ 0LPM GPM/ 0LPM Maximum

More information

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL DESCRIPTION 1. No mar 2. No mar tip 3. Housing grip 4. Trigger 5. Air inlet 6. Air inlet plug 7. Plastic board Important! It is essential that you read the

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10 LK product no: PCS 1-10 Article no: 74503 Revision:8 Article no: 74503 Revision: 8 2 (23) Contents 1. General information... 5 2. Safety precautions... 5 2.1 Significance of symbols... 5 2.2 Explanatory

More information

Pressure Relief Valve DHV 718

Pressure Relief Valve DHV 718 Advantages frictionless components low maintenance low pressure increase up to fully opened valve constant low vibration controlling hermetically sealed by diaphragm for oscillating pumps for viscous media

More information

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Differential Pressure Regulator Type 45-6 Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Edition March 2008 Contents Contents Page 1 Design and principle of operation...................

More information

30T A/Manual Hydraulic Shop Press

30T A/Manual Hydraulic Shop Press 30T A/Manual Hydraulic Shop Press Operation Manual 1 1. Important Information 1.1 Safety Information 1.1.1 Hazard Symbols Used in the Manuals This manual includes the hazard symbols defined below when

More information

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22. *09005087* DB_BA_EN_ME01_S Rev.A 12/16 *09005087* d e v e l o p i n g s o l u t i o n s Data Sheet and Operating Manual ME01 Digital manometer Table of Contents ME01 ## # 87 # HL S#### Dust explosion protection

More information

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

Pressure booster combination DPA-CRVZS. Operating instructions a [ ] Pressure booster combination en Operating instructions 8074546 2017-07a [8074548] Original instructions -EN Identification of hazards and instructions on how to prevent them: Danger Immediate dangers which

More information

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO 420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this

More information

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001 Ball valve Operating instructions for series Version BA-2016.02.05 Print-No. 300 587 TR MA DE Rev001 We reserve the right to make technical changes. Read carefully before use. Save for future use. ASV

More information

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight Technical Specifications Operating Instructions Maintenance Information Troubleshooting Guide Parts Diagrams AC1810 / AC1810-A THE EVOLUTION OF PERFECTION CAUTION: Before attempting to use or service this

More information

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13 24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: 2244030 OPERATION & MAINTENANCE INSTRUCTIONS LS10/13 INTRODUCTION Thank you for purchasing this product. Before attempting to use this product,

More information

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL 2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL Model: 52024 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement,

More information

Related Products: Auto Drain Valve. Model/Specifications. Model

Related Products: Auto Drain Valve. Model/Specifications. Model Related Products: Auto Drain Valve /600 Drainage is automatically discharged in a reliable manner, without requiring human operators. Highly resistant to dust and corrosion, operates reliably, and a bowl

More information

Manual winch MANISTOR 100 and 200

Manual winch MANISTOR 100 and 200 Manual wall winch Manual winch MANISTOR 100 and 200 Instruction manual UK 173-192.10-3 PRODUCT DEVELOPED AND MANUFACTURED ACCORDING TO NF EN 13157 STANDARD REGISTERED DESIGN To ensure the constant improvement

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) 42047 Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 45052 Constant Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor

More information

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027 Operating Instructions Ball valve fitting according to ZB 2553 For pressure transmitter VEGABAR 82 Document ID: 50027 Contents Contents 1 About this document 1.1 Function... 3 1.2 Target group... 3 1.3

More information

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 922 N 922 FTE Concept The diaphragm pumps from KNF are based on a simple principle - an elastic diaphragm, ixed on its edge, moves up and

More information

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator. LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the

More information

Operating instructions Diaphragm pump MP-520. Article No Original operating instructions. T-Dok-397-EN-Rev.0web

Operating instructions Diaphragm pump MP-520. Article No Original operating instructions. T-Dok-397-EN-Rev.0web GB Operating instructions Diaphragm pump MP-520 Article No. 200-0216 200-0330 Original operating instructions T-Dok-397-EN-Rev.0web Thank you for selecting a Krautzberger product. This product has been

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.

More information

MoveRoll Conveyor Operating and Maintenance Manual

MoveRoll Conveyor Operating and Maintenance Manual MoveRoll Conveyor Operating and Maintenance Manual 1. Read this first! This manual contains information for protection of personnel in the roll handling area from possible injury and/or equipment damage.

More information

Budget Range Operators Handbook

Budget Range Operators Handbook Budget Range Operators Handbook BAMBI AIR COMPRESSORS LTD 152 Thimble Mill Lane Heartlands Birmingham B7 5HT United Kingdom Tel: 0121 322 2299 Fax: 0121 322 2297 Email: sales@bambi-air.co.uk www.bambi-air.co.uk

More information

1. PARTS INTRODUCTION ELECTRICAL NOTES INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10.

1. PARTS INTRODUCTION ELECTRICAL NOTES INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10. CONTENTS 1. PARTS 3. 2. INTRODUCTION 4. 3. ELECTRICAL NOTES 5. 4. INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10. 8. ELECTRICAL CONNECTIONS 10/11. 9. SPECIFICATIONS

More information

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road PROPORTIONING VALVE Model 150 INSTRUCTION MANUAL March 2017 IMS Company 10373 Stafford Road Telephone: (440) 543-1615 Fax: (440) 543-1069 Email: sales@imscompany.com 1 Introduction IMS Company reserves

More information

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001 Modular valve block Operating manual Series MVB 100/200 Version BA-2016.04.20 EN Print-No. 300 627 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0

More information

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Type 0404 / 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions

More information

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE MODEL NUMBER: M20005 AIR SOURCE KIT 30% Duty Compressor on 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock

More information

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS VERTICAL AIR COMPRESSORS MODEL NO: VE15C150, VE18C150, VE25C150 PART NO: 2226010, 2226020, 2226025 OPERATION & MAINTENANCE INSTRUCTIONS LS0715 INTRODUCTION Thank you for purchasing this CLARKE Vertical

More information

User Manual. Quantos Automated Dosing Liquid Module

User Manual. Quantos Automated Dosing Liquid Module User Manual Liquid Module 1 Safety Information 1.1 Definition of warnings and symbols Signal Words WARNING for a hazardous situation with medium risk, possibly resulting in severe injuries or death if

More information

OWNER S TECHNICAL MANUAL

OWNER S TECHNICAL MANUAL EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids,

More information

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO 97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and

More information

Flowmeter. Original operating manual DFM

Flowmeter. Original operating manual DFM Flowmeter Original operating manual Series DFM 165 350 Version BA-2016.08.09 EN Print-No. 300 458 TR MA DE Rev002 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0

More information

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115 AIR COMPRESSOR MODEL NO: CHAMP 3 PART NO: 2225222 OPERATION & MAINTENANCE INSTRUCTIONS LS0115 INTRODUCTION Thank you for purchasing this CLARKE Air Compressor. Please read this manual fully before use

More information

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to: HANDBOOK Squeeze Off Unit SOU 400 Please refer any queries to: Hy Ram Engineering Co Ltd Pelham Street Mansfield Nottinghamshire NG18 2EY Telephone No: (01623) 422982 Please note all queries should state

More information

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP This operating instructions contains safety information that if ignored can endanger life or result in serious injury. They are indicated by this icon. Use of this pump with radioactive chemicals is forbidden!

More information

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) THE BP-301 SERIES Operating and Service Manual Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) Issue B October 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation...

More information

Non-Return Valve SRK 22A

Non-Return Valve SRK 22A Non-Return Valve SRK 22A Original Installation Instructions 819238-02 Contents Foreword... 3 Availability... 3 Formatting features in the document... 3 Safety... 3 Use for the intended purpose... 3 Basic

More information

A18W35_MASE 130_F_EN MANUAL

A18W35_MASE 130_F_EN MANUAL A18W_MASE 10_F_EN MANUAL CONTENTS 1 Identification 1.1 Manufacturer 1.2 Product name 1. Year of manufacture 1. Area of use 2 Technical specification 2.1 Design 2.2 Function 2. Technical data 2. Security

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 6 1. DESCRIPTION The Viking Model D-2 Accelerator is a quick-opening device, with an integral anti-flood assembly, used to increase the operating speed of a differential type dry pipe valve.

More information