Operating guidelines for wet-side and dry-side inflatables including Atlantis system

Size: px
Start display at page:

Download "Operating guidelines for wet-side and dry-side inflatables including Atlantis system"

Transcription

1 Airspace Solutions Inflatables Soft Play Trampoline Parks Operating guidelines for wet-side and dry-side inflatables including Atlantis system (0)

2 Wet-Side Inflatables & Giant Airshutes Dry-Side Inflatables Welcome! Thank you for purchasing this Airspace Solutions.com Ltd. Product. Your inflatable has been designed and manufactured to the highest quality standards and when cared for correctly will provide years of fun and enjoyment for your customers. This booklet will guide you through the use of your new inflatatable, from getting it out of the bag to putting it back in again and includes instructions on the correct set up of your inflatable as well as safety and operating guidelines. If you have any questions regarding any of the information in this booklet then please get in touch and we will be happy to help. We wish you and your customers many happy years of inflatable fun. Atlantis Airspace Solutions WARRANTY: IMPORTANT Please confirm receipt of this instruction manual by sending an , stating your business or site name and product purchased, to:

3 Wet-side inflatables Description These instructions are provided for all pool inflatable equipment, including sealed units, constant air units (eg. Aquaruns) and inflatable water slides (eg. Airshutes). Sealed inflatables require a hand-held blower. Once inflated, the blower is turned off and the inlet sealed with a cap and bung. A hand-held blower is not included with the product, but if required, one can be purchased separately from Airspace. Contact us for further information. Constant air inflatables need to be continuously inflated with a blower and flexible hose. The blower must be located in a safe location, away from poolside, preferably well away from the public. Your new constant air inflatable comes with an electric blower and a 10m length of flexible hose and all the correct fittings necessary. If you require additional lengths of hose, these can be purchased separately. Please contact Airspace for further information. If you have any doubts or questions about how your inflatable should be used, please do not hesitate to contact Airspace and we will be happy to assist you. Hazards Our products are manufactured to the highest standards and designed to provide years of enjoyment. However, as with all fun activities, there are risks associated with their use. These instructions are designed to indicate the potential hazards and risks associated with the use of our products and to advise you, the operator, on the measures that you need to take into consideration to reduce these potential risks. The following are potentially hazardous occurrences: User impact with the edge of the pool User impact with the bottom of the pool, due to the user falling off in to water of an insufficient depth. Insufficient depth of water at the end of the slide Inadequate tethering Injury caused by user impact with a tethering device Injury caused by using an electric blower in a wet environment Inadequate supervision of the users and the structure Injury caused by inappropriate or dangerous behaviour Overloading the structure with too many users causing damage or deflation, causing possible entrapment Exceptional use of the equipment leading to wear and/or damage possibly leading to deflation or entrapment Poor water quality leading to introduction of Pseudomonas organisms and possibly other forms of bacteria Injury cause by outdoor use in inappropriate conditions Weak swimmers out of their depth All of these can be minimised by purchasing the correct product for your intended location of use and by implementing proper supervision arrangements by appropriately trained staff. These steps will all assist in providing a safe and enjoyable activity for your customers. Wet-side inflatables 3 4

4 Wet-side inflatables Prior to Use A risk assessment must be carried out by the operator to determine the risks arising from the activity. This must include any measures necessary to reduce the risk. A manual handling assessment must also be carried out to determine the risks arising from the handling of the product. Some of our products are large and bulky and the assessment must determine how many staff are required and what equipment, if any, is needed to safely move the equipment from its storage location to its place of use. Unpacking and Inflating Before unpacking your product ensure that all the surfaces are clean and free of sharp or abrasive objects. If the product is to be unpacked on an abrasive surface, lay a protective ground sheet over the area to prevent damage to the product. Pay attention to the way in which the product has been packed. You will need to reverse your unpacking procedure after use when packing away for storage. The way your unit is rolled and packed when you first receive it is how you should pack and store it when not in use. Your manual handling assessment should detail how the product is to be handled. Wet-side inflatables Electrical safety is of paramount importance. The pool s electrical installation and its protective systems must be verified for adequacy and compliance with the Electricity at Work Regulations (1989). Fixed electrical installations should be inspected and tested at least annually and more frequently for equipment subject to more arduous conditions e.g. high humidity. Never drag the structure across the floor. Always move the product in the storage bag provided; your manual handling assessment may highlight the need for a trolley or other type of moving equipment. Before inflating the product, unwrap it fully and lay it flat on the poolside. Written operating procedures, including normal operating procedures and emergency action plans must be devised. These Airspace user instructions are NOT designed to replace or provide a written operating procedure, they are provided as a guide to help you develop your own procedures. Training in the safe handling and proper use of our product must be undertaken prior to its use. Product training is available on request on all Airspace products by your trained Account Manager. 5 6

5 Wet-side inflatables Safe use of Electrical Blower The following precautions should be taken, as a minimum, to ensure safe use of the electrical blower: The blower must be connected to a supply voltage corresponding to the electrical rating of the blower as indicated. Unplug the blower before moving. Residential current circuit breakers (RCCBs) should be tested daily by operating the test button, or if used less than once a day, tested every time they are used. Do not operate with a damaged supply cord or plug, after it malfunctions, or after it has been damaged Inflating a Sealed Inflatable To inflate, remove the red cap, remove the bung and place the nozzle of the blower over the inlet hole. Keep the cap and bung safe. Ensure hands are completely dry before using the blower and make sure that the area in which the blower is used is also completely dry. If an extension lead has been used, ensure it is fully unwound to prevent over-heating. Make sure that there are no trailing leads. Wet-side inflatables in any way. Do not overload electrical outlets beyond their capacity as this can result in fire or electrical shock. Do not alter the attachment plug. The plug is configured for the appropriate electrical supply. Never put objects into the ventilation holes on the blower unit. Do not spill liquid of any kind on the blower. Blowers must be situated a minimum of 2m away from the basin area Care must be taken not to over-inflate the product which, when correctly inflated, will be firm but have some give. It is always better for the unit to be on the soft side than for it to be too firm. When the product is sufficiently inflated, remove the nozzle, replace the bung and screw on the red cap. When the red cap is secure ensure that no part of the inlet protrudes beyond the body of the structure by pushing the nozzle into the inflatable. The 12 month warranty does not include damage to the product caused by over-inflation. Electrical cables must be safely routed out of the way and taped down if necessary Any electrical device supplied as part of your order should under no circumstances be used near water. Operators should carry out their own on site risk assessment and produce guidelines on safe use of electrical equipment. Always use the inflation point furthest from water 7 8

6 Wet-side inflatables Inflating a Constant Air Structure Aquaruns are constant blow, or constant air, devices. This means they must always have air flowing through them with a constant feed to maintain their shape and structural integrity. The blowers for these products are freestanding devices, which must be sited away from the pool tank, in accordance with the relevant requirements (UK: Electricity at Work Regulations 1989). 10 metres (32ft 6ins) of flexible hose is provided with the product as standard. If this is insufficient for your site, further hosing can be purchased from us. Connect one end of the hose to the blower outlet with the jubilee clip supplied. Place the other end of the hosing inside the inlet sleeve and further into the main body of the inflatable itself by at least 30cm. (If the hose is not inserted fully into the inflatable and is only in the sleeve, the pressure will blow the hose out and cause the unit to deflate whilst in use.) Fasten the webbing strap on the inlet sleeve tightly to secure the hose firmly in place. The blower MUST continue to run whilst the unit is in use and on the water. Do not turn off the blower if the unit is on the water. Positioning, Securing and Clearance from Pool Sides Sealed Units: One of the biggest risks to users of pool inflatables is falling off the inflatable and striking the pool edge. To minimise the risk of injury there should be a minimum clearance of 2m (6ft 6ins) on all sides of the inflatable. Diving from, or standing on structures is prohibited. This must be enforced through appropriate signage, user instructions and staff supervision arrangements. Additional Clearance requirements Aquaruns: A possible hazard arising from the use of an Aquarun is the danger of falling backwards from the structure and hitting the edge of the pool. To prevent this from occurring, the start of the structure (known as the jump bed or platform ) can be positioned 1m up to a maximum of 1.5m from the poolside so that users enter the unit with a forward motion. However, if the access to the inflatable is attended by a trained member of staff, access can be allowed directly from the edge of the pool. The role of the attendant is to prevent running access which increases the likelihood of slipping and impact with the pool surround. The end (finish) of the inflatable should be situated as least 2.5m (8ft 1ins) away from the edge of the pool. In addition, there should be a clearance of at least 2.5m (8ft 1ins) from each side of the pool tank. Wet-side inflatables 9 10

7 Wet-side inflatables Clearance from roof structures - all products When an inflatable with a slide is being used, care should be taken to ensure that there is adequate headroom above the inflatable. It is recommended that there be at least 3m (10ft) clear headroom above the overall height of the slide. Anchoring pool structures all products To minimise the hazards associated with inadequately secured inflatables, they should always be securely anchored in the appropriate location with the clearances outlined above. Airspace products are supplied with bungee cord tied to the anchor points. These are designed to allow some movement during use. These bungee cords should not be removed as this will result in excessive strain on the anchor points, possibly causing the inflatable to tear. Ropes used to secure the inflatable to the poolside or pool bottom must be highly visible and must not be tensioned too tightly, otherwise damage could occur to the anchor points on the structure. Ropes must be attached to the bungee cord provided and should form an angle of approximately 30 degrees when sited appropriately. 12.5m 6.7m 5.8m Typical Aquarun Set Up 2.5m Clearance Area 25m 15.5m Dual Lane Aquarun 2.5m Clearance Area Swim Lane Swim Lane Slide Exit 1.9m 1.9m Wet-side inflatables The 12 month warranty does not include damage to the product caused by bungee ropes being removed or by the unit being tethered too tightly. Swim Lane 1.9m 11 12

8 Wet-side inflatables Water Depth For smaller sealed units without a high fall off height, there should be a minimum depth of around all sides of the inflatable. This will reduce the risk of head/spinal injuries from children falling off the inflatable. Ideally the pool depth will be consistent on all sides. Users may not appreciate the varying depths or become disorientated and find themselves out of their depth and in difficulties. Large constant blow inflatables should only be used in pools where the depth at the shallow end is at least (2ft 11ins). Where structures are particularly large with a fall off height, water depth of at least 1.5m (5ft) is required. Additional notes on Dual Lane Aquaruns Dual Lane Aquarun runs are designed for two users to race each other with a dividing wall. The width of a Dual Lane Aquarun is 1.7m; this is 30cm wider than a standard Airspace Aquarun so your Normal Operating Procedures must be updated from any previous single lane inflatable you may have been accustomed to. For a 15.5m Dual Lane Aquarun, six users can race down the run (3 users per side). Where there is no dividing wall, attendants should encourage each user to stay on their side of the run and avoid any fighting or boisterous play. Wet-side inflatables No inflatable play structure should have a fall off height higher than 1m (3ft 3.37ins) unless there is sufficient depth of water. The ISRM code of practice, Diving in Swimming Pools should be consulted for further information. Where the inflatable has a small slide as an exit point, the depth of water must be suitable. Where the inflatable has a slide and the water depth at the exit is less than 1.8m (5ft 11ins) the lifeguards should be vigilant to prevent users diving off the top off the slide. Where water depth is less than 1.5m (5ft) ALWAYS consult the manufacturer

9 Wet-side inflatables When In Use Maximum Numbers / Maximum Height / Weight of Users The pool s normal operating procedures should detail the maximum number of people and age ranges allowed on the structure at any one time. These, in part, will be determined by supervision levels. We do not specify a maximum height or weight for our sealed units or constant blow products. However, we do recommend the following maximum numbers at any one time. Safe Use Ensure users only access the inflatable when instructed to do so by the supervisor. Users should listen to the supervisors and obey instructions. Where the inflatable is an Aquarun type or has a slide exit, users must swim to the nearest side, leave the pool and re-join the queue Users should only be permitted to go down the slide feet first. Users should NEVER stand or attempt to stand on any sealed structure and should only kneel or sit on Wet-side inflatables Sealed Structures them. Small Structures 3 users maximum at any one time Large Structures 8-10 users maximum at any one time Single Lane Aquaruns 3 Users maximum at any one time, one at the start, one in the middle and one at the end. Dual Lane Aquaruns 6 Users maximum at any one time, 3 each side of the dividing wall. One at the start, one in the middle and one at the end. Users should not be permitted to wear shoes and should remove jewellery, watches, hard objects etc. that may cause damage or injury to the equipment or other users. If locker keys are worn care should be taken to ensure that the key is retained completely within its plastic strap. Children should not be allowed to play in a boisterous manner, which is likely to cause harm to themselves or others. Diving from the inflatable should be prevented. Swimming under the inflatable should be prevented. Users must not pull or swing on the tethering ropes, nor attempt to lift the structure Aquarun users must be instructed to jump forwards onto the Aquarun to provide forward momentum and reduce the possibility of falling backwards and striking the poolside

10 Wet-side inflatables Supervision Arrangements It is the responsibility of Pool Operators to carry out their own risk assessment. This should detail the number of staff required to safely supervise the structure(s). Consideration will need to be given to the age, height and swimming ability of the users, the depth of the water in which the structure(s) is being used, the maximum numbers permitted in the session and the maximum number on the structure at any one time and the degree to which the structure prevents a clear view of the pool bottom. For Aquaruns, consideration will also need to be given to queuing arrangements and ensuring that only permitted numbers are on the Aquarun at any one time. The staffing requirements should be detailed in the pool s normal operating procedures. Use Outdoors Structures may be used in outdoor locations provided all tethering and positioning requirements are met. Careful consideration must be given to the wind prevailing at the time of use and also the anticipated forecast. Monitor the wind constantly when in use. It is recommended that an anemometer (device for measuring wind speed) is used to monitor the wind conditions. If the wind exceeds, or is forecast to exceed 24 mph, cease operating the inflatable. Get all users off safely and as quickly as possible. In the event, or forecast or even suggestion of thunder and lightning, stop the session immediately and turn off the blower. Wet-side inflatables Sealed inflatables should be carefully checked on a regular basis when used outdoors since large changes in temperatures and direct sunlight can cause significant pressure differences within the inflatable. Airspace can position anchor points at the side of the structure or underneath for bottom tethering for use outdoors. You must specify bottom tethering at point of order if you require this

11 Wet-side inflatables Cleaning, drying, deflating and re-packing Cleaning: To help reduce any risk arising from the development of bio-films on the surface of the product which may harbour Pseudomonas organisms, the following procedures should be carried out. If the product is slimy, appears to have a scum line or appears otherwise unclean, the inflatable must be hosed down with fresh water. If the dirt/slime remains, you can clean with a dilute Chlorine solution and then follow by hosing down with fresh water. Wearing appropriate personal protective equipment is paramount. DO NOT use pool water to clean the structure. Deflating: Remove the structure from the pool. Do not pull the unit by the anchor points or put strain in any one particular place. Sealed inflatables: Unscrew the red cap and remove the bung. Constant air inflatables: Remove the hose from the unit. Open all air vents where applicable and allow all the air to escape. Depending on the type of blower it may be possible to reverse the operation to draw the remaining air out of the structure. Re-packing: The structure should be re-packed in its original bag for storage. Correct folding, rolling and packing is covered in the Airspace onsite training. Never pack away whilst still wet. Wet-side inflatables The structure must be inflated whilst the cleaning and hosing down is taking place, if the unit is deflated, water will seep through the seams (Aquaruns only) and this will cause the unit to rot from the inside. Once the cleaning has taken place, the unit must be dried. Drying: It is important that the product is dried after use. Failure to follow this instruction will cause mildew to form on the product, which causes staining and will speed up the process of delamination. Storage: Our products should be stored in a dry place. Do not store in direct sunlight as this can encourage mildew to grow. Under no circumstances should structures be stored inflated on the poolside since heat gain will cause the air to expand and put excessive pressure on the seams which could cause the structure burst. If structures are stored outdoors or in very low temperatures, they should be brought into the area where they are to be used in advance and the structure allowed to acclimatise before inflation. Cold temperatures cause the material to become brittle. Failure to allow acclimatisation to take place may result in damage to the structure. The 12 month warranty does not cover damage caused by this eventuality. Drying the structure thoroughly with dry towels before deflating will greatly extend the life of the product. The Manual Handling Assessment, undertaken prior to use, should detail how the product is to be moved and how many staff are required to carry out this task. Approximate weights of your product can be obtained from your Account Manager

12 Wet-side inflatables Inspection and Maintenance Requirements Prior to Use The product should be inspected prior to each use with particular attention being paid to the following: The condition of the anchorage points on the structure and on the pool tank. Ropes used for tethering are not worn or chaffed. There are no holes or rips in the fabric and seams. Examine the hose connection point, ensuring it is secure and without leaks. The correct blower specified for the device is being used and that the air pressure is sufficient to maintain the required firmness. The integrity of the blower including appropriate secured guards over the air inlet and outlet. The blower/inflation tube connection is in good condition and is firmly attached to the blower. Minor Repairs To repair a small puncture, make sure the area is clean and dry. Prepare a suitably sized PVC material patch from the patching kit supplied we recommend that you cut this with rounded corners to help it remain in place and so no sharp edges are present. Apply the glue supplied to the area around the puncture and to the back of the patch. Allow to become tacky. Fit the patch and apply moderate pressure, leaving to set for 12 hours. Ensure that the patch is securely fixed to the product before re-use. Take care to ensure that this activity is carried out in a well-ventilated dry area. If you require repairs, service or maintenance to the electrical blower, this must be carried out by an appropriately qualified and competent person. Wet-side inflatables The blower is positioned correctly, adequately protected or guarded and is not causing a tripping hazard. The condition of the electrical system, including the integrity of the electrical contacts, electrical cables, plugs, sockets and switches. Annual Inspection All Inflatables should be inspected annually by a qualified company. Airspace can carry out these inspections and provide inspection certificates contact us on the anniversary of the delivery of your product. The product should not be used until any defects identified have been rectified. Your product carries a warranty for 12 months. We also provide you with a repair kit which enables you to carry out minor repairs yourself on site, thus reducing downtime. Repairs can be carried out by an Airspace engineer onsite or in the factory. Additional repair kits can be purchased from Airspace. Onsite inspections are available

13 Giant Airshutes Giant Airshutes Description These user instructions are provided for our constant blow inflatable Giant Airshutes and standalone slides. The Giant Airshute is an inflatable slide developed and manufactured by Airspace following our work with the airline industry, providing safe, effective airline escape chutes for use in training sessions. We have adapted these to become fun structures that can be used to replace or better utilise 3 metre spring or fixed diving boards. They can also be used in conjunction with a custom designed stainless steel frame and platform. The standard Giant Airshute has an active sliding length of 8m (26ft), with users safely channelled between 2 larger air filled side tubes. The end of the slide flattens out so the users land gently on the water, skimming across the surface, rather than directly entering it upon descent. The Giant Airshute is designed to be fixed at a height of 3m above water level to maintain a correct angle of descent. Airspace Solutions.com Ltd cannot be held responsible for injuries howsoever caused if this requirement is not adhered to. Giant Airshutes need to be secured to a diving platform or frame with a bar. As with the constant blow Aquarun inflatables, the giant Airshutes are required to be continuously inflated with a blower located in a safe location away from poolside and connected to the product with a length of flexible hosing. Your product normally comes with a blower and a 10m (32ft 6ins) length of flexible hose. Additional lengths of flexible hose can be purchased if required. Contact Airspace for further information. If you are in any doubt about how your inflatable should be used please do not hesitate to contact Airspace at any time and we will be happy to assist. Giant Airshutes can range from 65kgs 150kgs depending on the size and design. A risk assessment must be carried out onsite to determine the safest Manual Handling Procedure. A standalone slide is a simple up and down slide that is attached to the side of the pool in the same way as an Aquarun. All Airspace standalone slides have high safety tubes and an extended run out. Hazards The following are potential hazards when using Airshutes: Impact with the pool bottom as a result of insufficient depth of water at the base of the slide. Impact with another user as a result of inappropriately sized and sectioned off landing area. Using an electric blower in a wet environment. Inadequate supervision of the structure. Inappropriate behaviour. Poor water quality leading to possible contamination of the Giant Airshute with Pseudomonas organisms leading to the development of an itchy rash. Injuries caused by outdoor use in high winds or bad weather. All of these can be minimised by ensuring that the structure is suitable for the location in which it is intended to be used. Proper supervision arrangements and staff training in the safe use of the structure can assist in providing a safe and enjoyable activity for customers Giant Airshutes

14 Giant Airshutes Prior to Use A risk assessment must be carried out by the Operator to determine the risks arising from the activity and must include any measures necessary to reduce the risk. A Manual Handling Assessment must also be carried out to determine the risks arising from the handling of the product. Some of our products are large and bulky and the assessment must determine how many staff are required and what equipment, if any, is needed to safely move the equipment from its storage location to its place of use. Care must be taken in handling and transportation. The following precautions should be taken, as a minimum, to ensure safe use of the electrical blower: The blower must be connected to a supply voltage corresponding to the electrical rating of the blower as indicated. Unplug the blower before moving. Residential current circuit breakers (RCCBs) should be tested daily by operating the test button, or if Giant Airshutes Electrical Safety is of paramount importance. used less than once a day, tested every time they are used. The pool s electrical installation and its protective systems must be verified for adequacy and compliance with the relevant regulations. Fixed electrical installations should be inspected and tested at least annually and more frequently for equipment subject to more arduous conditions e.g. high humidity. Written Operating Procedures, including Normal Operating Procedures and Emergency Action Plans, must be devised. Do not operate blower with a damaged supply cord or plug, after it malfunctions, or after it has been damaged in any way. Do not overload electrical outlets beyond their capacity as this can result in fire or electrical shock. Do not alter the attachment plug. The plug is configured for the appropriate electrical supply. Never put objects into the ventilation holes on the blower unit. These User Instructions are not designed to replace or provide a written operating procedure, but they will help to guide you through some of the factors that you need to consider in developing your own procedures. Training in the safe handling and proper use of our product must be undertaken prior to its use. Do not spill liquid of any kind on the blower. Blowers must be situated a minimum of 2m away from the basin area Electrical cables must be safely routed out of the way and taped down if necessary Any electrical device supplied as part of your order should under no circumstances be used near water. Operators should carry out their own on site risk assessment and produce guidelines on safe use of electrical equipment

15 Giant Airshutes Installation of Frame and/or Stauff Clamps Installation of Frame: Giant Airshutes can be installed on adapted 3 metre springboard stands. Generally, this involves removing the springboard and adapting the frame by installing a walkway between the existing handrails and building a suitable platform extending beyond all existing handrails. The slide anchor bar is attached using stauff clamps, as detailed below. Leading Edge Preparation: Ensure that the leading edge of the platform is covered in a smooth, non-abrasive material to prevent abrasion of the underside of the slide and anchor bar sleeve during use of the slide. NOTE: Failure to follow this important preventative maintenance guideline may result in excessive damage to your slide that is not covered by our 12 month warranty. Giant Airshutes Installation of Stauff Clamps: Prior to purchase, advice should be sought to ascertain the correct bar and clamp requirement. Airspace can provide a specification of the slide on request to aid with you sourcing the correct bar and clamp. Stauff or D Clamps are to be used on 3 metre diving platforms, adapted 3 metre springboards, wood framed platforms and for installations utilising existing viewing balconies. Two sets of stauff or D clamps and a 2m (6ft 6ins) long by 50mm (1.4ins) wide metal bar are required for installation. The operator should source these items separately. The clamps should be installed in accordance with the manufacturer s instructions. If they are to be installed in concrete this will require the use of stainless steel expansion bolts so that the female part is set just below the surface of the decking and will remain in situ even when the clamps themselves have been removed after the end of the session. Ensure a qualified engineer does the installation. The Stauff or D clamps should be positioned a minimum of 23cm (9ins) back from the leading edge of the platform and be at least a distance of 1.67m (6ft) apart. Before unpacking your product ensure that all surfaces are clean and free of sharp of abrasive objects. If the product is to be unpacked on an abrasive surface, lay a protective ground sheet over the area to prevent damage to the product. Pay particular attention to the way in which the product has been packed. You will need to repeat this process after use when packing away for storage. Your manual handling Assessment should detail how the product is to be handled. Never drag the structure across the floor. Unpacking Always move it in its storage bag, and where necessary on a trolley or other equipment, as specified in your manual handling assessment. Before inflating the product, unwrap it fully and lay it flat on the poolside

16 Giant Airshutes Inflating and Installing the Airshute Attach the air inlet hose to the aluminium outlet on the side of the Airshute and to the round outlet on the blower. Ensure that the blower is in a safe, dry place away from bathers. Slide the metal anchor bar through the sleeve provided on the Airshute. Tie approx 6m (20ft) of 19mm (1ins) rope to the both ends of the anchor bar, using a secure knot. You will use this rope to carefully lift the Airshute up to its required position. Inflate the Airshute on the poolside. When firm, lift and place it in the water, making sure that the lifting ropes are held securely by staff. Float the Airshute out into the pool until the back end of it is directly below whichever platform or frame you are utilising. The Airshute is a constant blow inflatable, with stitched side seams. Do not be alarmed if air is leaking from the seams this is quite normal and does not mean the Airshute is faulty. Pass the ends of the rope up to a minimum of 2 people on the platform and carefully lift the Airshute up into its desired position. When the inflated Airshute has been lifted up to the platform, the Anchor Bar should be placed into the bracket sections of the stauff or D Clamps. When positioned evenly between the clamps tighten firmly so they cannot be unbolted by hand. If problems are experienced refer back to the clamp manufacturers mounting instructions and check that you have followed them correctly. Positioning, Securing and Clearance from Pool Sides Airshutes must be fixed to a diving platform or stainless steel platform by a bar which runs through the sleeves in the structure. They must be positioned so that there is no possibility of users striking the poolside from any part of the structure. A clearance of 3.65 (11ft) from the edge of the poolside is recommended. There must be sufficient forward clearance at the landing area: a minimum distance of 4.57m (15ft) is recommended. Ideally the area should be separated from the remainder of the pool by a roped partition or the use of an inflatable boom, which can be purchased from Airspace, if required. Clearance from Roof Structures All Products When an inflatable with a slide is being used, care should be taken to ensure that there is adequate headroom above the inflatable. Normally there should be at least 3m (10ft) clear above the height of the slide. The correct positioning should be detailed in the pool s Normal Operating Procedures. Anchoring Pool Structure All Products To minimise the hazards associated with inadequately secured inflatables they should always be securely anchored in the appropriate location prior to the start of the session. Giant Airshutes Water Depths For Giant Airshutes and a standalone slide with an extended run off and high safety tubes a depth of 1.5m (5ft) is required

17 Giant Airshutes A small amount of water should be run down the Giant Airshute during use. Do not spray from above as this may fill the structure with water and cause significant damage. Use the anchor points provided on the inside of the slide walls at the top of the slide to position a hose. Ensure that the Giant Airshute is positioned correctly before anyone is permitted to use the structure. Landing Area When In Use A landing area of 4.57m (15ft) directly in front of the structure and 3.65m (11ft) to either side should be established. It is preferable to mark this area with an inflatable boom. Alternatively, a rope with high visibility floats should be used. Inflatable booms can be purchased from Airspace contact us for more information. Supervision Arrangements It is the responsibility of Pool Operators to carry out their own risk assessment which should detail the number of staff required to safely supervise the Giant Airshute. Consideration will need to be given in relation to queuing arrangements and supervision, supervision of the launch area and supervision of the landing area. Other considerations will include any requirements for minimum age or height of users and swimming ability. Some of these aspects may be dealt satisfactorily by the provision of appropriate signage. The pool s Normal Operating Procedures should specify the number of staff required and whether staff are also responsible simultaneously for supervising other areas of the pool. As a minimum, one suitably qualified and trained member of staff should be positioned at the point of descent or on the poolside below. They are to ensure that the splash area is free before allowing descent of the slide. All users should remain on the poolside whilst waiting their turn. Giant Airshutes Maximum Weight of Users Airspace Giant Airshutes are designed for use by people of all ages. However, the life expectancy of the product is directly related to the care taken during the set up and takedown, the intensity of the use and the weight of the users. For this reason, it is recommended, based on experience, that users should weigh less than 102kg (225lbs)

18 Giant Airshutes Safe Use Users should not be permitted to wear footwear and should remove jewellery, watches, hard objects etc. that may cause tears or injury to others. If locker keys are worn, care should be taken to ensure that the key is retained completely within its plastic strap. Only one person should use the Giant Airshute at any one time. Chains of users should not be permitted Use Outdoors The Giant Airshute may be used in outdoor locations provided all mounting, installation and operational requirements are met. Particular consideration must be given in these circumstances to the use of electrical blowers and weather conditions. Giant Airshutes at any time. Careful consideration must be given to the wind prevailing at the time of use and also the anticipated The landing area must be cleared before the next person uses the Giant Airshute, to avoid collision forecast. Monitor the wind constantly when in use. It is recommended that an anemometer (device for between users. measuring wind speed) is used to monitor the wind conditions. Users should only slide down feet first. If the wind exceeds, or is forecast to exceed 24 mph, cease operating the inflatable. Get all users off Users should not be permitted to run or dive head-first or otherwise launch themselves aggressively safely and as quickly as possible. onto the Giant Airshute. In the event, or suggestion of thunder and lightning, stop the session immediately and turn off the Users should listen to the pool attendant and obey any instructions given. blower. Users must swim to the nearest side of the pool after exiting the slide, leave the pool immediately and rejoin the queue if wishing to slide again. Users must not hang onto any ropes or inflatable tubes used to designate the landing area

19 Giant Airshutes Cleaning, Drying, Deflating and Re-packing Cleaning To help reduce any risk arising from the development of bio-films on the surface of the product which may harbour Pseudomonas organisms, the following procedures should be carried out. If the product is slimy, appears to have a scum line or appears otherwise unclean, the inflatable must be hosed down with fresh water. If the dirt/slime remains, you can clean with a dilute Chlorine solution and then follow by hosing down with fresh water. Deflating Remove the hose from the product (constant blown inflatable). Open all air vents where applicable and allow all the air to escape. Depending on the type of blower it may be possible to reverse the operation to draw the remaining air out of the structure. Re-packing: The structure should be re-packed in its original bag for storage. Correct folding and packing is covered in the Airspace onsite training. Never pack away whilst still wet. Giant Airshutes DO NOT use pool water to clean the structure. The structure must be inflated whilst the cleaning and hosing down is taking place, if the unit is deflated water will seep through the seams and this will cause the unit to rot from the inside. Once the cleaning has taken place the unit must be dried. Wearing appropriate personal protective equipment is paramount. Storage Our products should be stored in a dry place. The Manual Handling Assessment, undertaken prior to use, should detail how the product is to be moved and how many staff are required to carry out this task. Drying It is important that the product is dried after use. Failure to follow this instruction will cause mildew to form on the product, cause staining and will speed up the process of delamination. The 12 month warranty does not cover this damage caused by this eventuality. Drying the structure thoroughly with dry towels before deflating will greatly extend the life of the product

20 Giant Airshutes Inspection and Maintenance Requirements Prior to use The product should be inspected prior to each use, with particular attention being paid to the following: The condition of the anchorage points on the structure. Ropes used for tethering are not worn or chaffed. There are no holes or rips in the fabric and seams, also examine the hose connection point. The correct blower specified for the devise is being used and that the air pressure is sufficient to maintain the required firmness. The integrity of the blower including appropriate secured guards over the air inlet and outlet. Minor Repairs To repair a small puncture, make sure the area is clean and dry. Prepare a suitably sized PVC material patch from the patching kit supplied we recommend that you cut this with rounded corners to help it remain in place and so that no sharp edges are present. Apply the glue supplied to the area around the puncture and to the back of the patch. Allow to become tacky. Fit the patch and apply moderate pressure, leaving to set for 12 hours. Ensure that the patch is securely fixed to the product before re-use. Take care to ensure that this activity is carried out in a well-ventilated dry area. If you require repairs, service or maintenance to the electrical blower, this must be carried out by a trained, appropriately qualified and competent person. Giant Airshutes The blower/inflation tube connection is in good condition and is firmly attached to the blower. The blower is positioned correctly, adequately protected or guarded and is not causing a tripping hazard. The condition of the electrical system, including the integrity of the electrical contacts, electrical cables, plugs, sockets and switches. The structural integrity of the supporting structure, and stainless steel frame, should be examined periodically. The product should not be used until any defects identified have been rectified. Your product has a warranty for 12 months. We also provide you with a repair kit, which enables you to carry out minor repairs yourself on site, thus reducing down time. Repairs can be carried out by an Airspace engineer onsite or in the factory. Additional repair kits can be purchased from Airspace

21 Dry-side inflatables Description These User Instructions are provided for our land based inflatable equipment. They may be used in indoor or outdoor locations and may either be purchased off the shelf or can be designed to fit specific locations. Discuss with your account manager which option best suits your requirements. Land inflatables may be linked together to provide further exciting opportunities and may include features such as small slides and ball pools. Our structures are constant air inflatables which are required to be continuously inflated with a blower which is located in a safe location away from users, connected to the product by an inlet sleeve a minimum distance of 1.2m to the blower cone. Air can and does constantly escape through the stitched seams of the inflatable. Do not be alarmed, this is normal. If you are in doubt about how your inflatable should be used please do not hesitate to contact Airspace at any time and we will be happy to assist. Hazards The following are potentially hazardous occurrences: Injuries caused by impact with floor or wall surfaces Injury caused by impact with a tethering device. Injury caused by contact with an electrical blower. Injuries caused by inadequate supervision of the structure. Injuries caused by inappropriate or boisterous user behaviour particularly in relation to use by incompatible age groups. Injuries caused by overcrowding within the structure. Poor cleanliness and hygiene standards leading to contamination of the structure and illness for those in contact with the structure. Injuries caused by outdoor use in inappropriate conditions, particularly during periods of high winds, adverse weather or through dangerous location of structures. Injuries caused by failure of the structure as a result of storage and/or use in very low temperatures Dry-side inflatables Our products are manufactured to the highest standards and designed to provide years of enjoyment. (less than 4 C). All our products, where applicable, are designed to conform to EN 14960: All these can be minimised by purchasing the correct product for the location in which it is intended to be used and by implementing proper setup and supervision arrangements by appropriately trained staff. However, in line with all other fun activities, there are risks associated with their use. These instructions for use are designed to indicate the possible hazards of our products and inform you, the operator, of measures that you need to take to reduce the risks for your customers

22 Dry-side inflatables Prior to Use A risk assessment must be carried out by the operator to determine the risk arising from the activity and must include any measures necessary to reduce risk. A manual handling assessment must also be carried out to determine the risks arising from the handling of the product. Some of our products are large and bulky and the assessment must determine how may staff are required and what equipment, if any, is needed to safely move the equipment from its storage locations to its place of use. Electrical safety is of paramount importance. The centre s electrical installation and its protective systems must be verified for adequacy and compliance with the regulations. Fixed electrical installations should be inspected and tested at least annually and more frequently for equipment subject to more arduous conditions e.g. high humidity. Unpacking and Inflating Before unpacking your product ensure that all surfaces are clean and free of sharp or abrasive objects. If the product is to be unpacked on an abrasive surface, lay a protective ground sheet over the areas to prevent damage to the product. Only use the structure on a level surface. Pay particular attention to the way in which the product has been packed. You will need to repeat the process after use when packing away for storage. Your manual handling assessment should detail how the product is to be handled. Never drag the structure across the floor. Dry-side inflatables Written operating procedures, including normal operating procedures and emergency actions plans must be devised. Always move it in its storage bag, and where necessary on a trolley or other equipment, as specified in your manual handling assessment. These user instructions are not designed to replace or provide a written operating procedure, but they will help to guide you through some of the factors that you need to consider in developing your own procedures. Training in the safe handling and proper use of our product must be undertaken prior to its use. Before inflating the product, unwrap it fully and lay it flat on the floor. Please do not force open zips. In the event of a zip getting stuck, please deflate the castle and then gently release the zip before re-inflating

23 Dry-side inflatables Safe use of Electrical Blower The following precautions should be taken, as a minimum, to ensure safe use of the electrical blower: The blower must be connected to a supply voltage corresponding to the electrical rating of the blower as indicated. Unplug blower before moving or when it is not in use for extended periods of time. Residential current circuit breakers (RCCBs) should be tested daily by operating the test button, or if used less than once a day, tested every time they are used. Do not operate with a damaged supply cord or plug, after it malfunctions, or after it has been damaged Inflating a Constant Blow Structure Bouncers, slides, some domes, activity centres and custom land inflatables are constant blow devices which mean they are always at the correct operating pressure and cannot be over-inflated. The blowers for these products are freestanding devices and should be used in accordance with the relevant requirements (UK: Electricity at Work Regulations 1989). The blower is attached to the structure by an inlet sleeve. The sleeve must be a minimum distance of 1.2m to the blower cone, which must not be shortened under any circumstances. Dry-side inflatables in any way. Do not overload electrical outlets beyond their capacity as this can result in fire or electrical shock. Do not alter the attachment plug. The plug is configured for the appropriate electrical supply. The blower should be positioned so that the inlet pipe is straight once inflated. Ensure the sleeve is not twisted, as air will not flow through properly. Never put objects into the ventilation holes on the blower unit. Do not spill liquid of any kind on the blower. Use only the blower supplied with your inflatable. Blowers must be situated a minimum of 2m away from the basin area Electrical cables must be safely routed out of the way and taped down if necessary Any electrical device supplied as part of your order should under no circumstances be used near water. Operators should carry out their own on site risk assessment and produce guidelines on safe use of electrical equipment

24 Dry-side inflatables Positioning and Securing: Use Indoors and Outdoors Positioning The inflatable shall be well away from possible hazards such as overhead power lines or other obstacles with hazardous projections (eg. Fences and/ or trees). All structures should be used on a flat, level surface. The inflatable should not be erected on a site with more than 5% slope in any direction. Make sure the site is cleared of any debris and/or sharp objects either on or embedded in the surface. A clear area, free of any obstacles that could cause injury, shall be maintained around the inflatable. The minimum clear area is 1.8m from any walled side of the inflatable and at least 3.5m from open sides of the inflatable. Also, make sure this clear area is also free of any obstruction that may hinder the visibility of any supervisors. Use Indoors Securing The structure must be secured adequately, particularly if there is any danger of the structure moving as a result of being used on a highly polished or slippery surface. Sand bags can be purchased if required. Contact Airspace for more help. Use Outdoors Securing If the structure is to be used on an abrasive surface e.g. concrete or tarmac, or on a dirty area e.g. one covered by oil or grease, then a ground sheet should be used to prevent damage to the underside of the structure. The 12 month warranty does not include damage caused in this manner. Particular attention must be paid to the means of anchoring a structure when used outdoors. Dry-side inflatables Ensure that users cannot come in to contact with the blower or any other electrical component or tethering device. Where the structure is being used in outdoor locations and is likely to prove a significant attraction, a crowd control barrier must be erected as least 3.5m (11ft) from the front. The barrier should be at least 1m (3ft 3ins) high and capable of withstanding people leaning or being pushed on it. If the public do not have access to the rear and sides of the unit then a more limited crowd control barrier can be provided at the front only, so that the structure can be properly supervised and users have safe access and egress. Any gate in this barrier shall be at least 1.0m wide. The correct positioning of any barrier should be detailed in the centre s normal operating procedures. It should be secured thoroughly to the ground by use of anchor stakes secured into the ground, where the surface is suitable. Your inflatable has been designed with safety in mind. Use ALL the anchor points fitted to your inflatable and secure with stakes. Drive the stakes in to the ground so that no more than 2.5cm or 1 inch is protruding from the ground. When this is not the case then other means of securing the inflatable should be considered e.g. sand bags or other ballast

25 Dry-side inflatables Your unit had been designed and manufactured to comply and, in many cases, exceed the standard BS EN 14960:2013. Do Not Operate In High Winds. If the wind speed is, or is forecast to be, 24mph (38kph, Beaufort 5) or over, on the day you are operating DO NOT use your inflatable. We strongly recommend that you consult a recognised and reliable weather forecasting service before intending to set up your inflatable and throughout the day. A small, hand held anemometer (devise for measuring wind speed) is a useful device to carry with you on all occasions. Use And Secure All Anchor Points. Use The Stakes Provided. Around the perimeter of your inflatable are anchor points and you have been supplied with steel anchor stakes. ALL of these MUST be used at all times. Check the suitability of the ground. If it is too soft or unstable, or the ground is unlevel be more than 5 degrees in any direction, site your inflatables elsewhere. Use of your inflatable Check Before Use: Before users are permitted to use the structure the following checks should be performed: The integrity of anchorage points. Blower and inlet pipes. Sufficient pressure within the structure. Investigate any reason for an area that is not correctly inflating. No visible hazards (eg. damage or tears to the structure or seams which may prove to be an entrapment hazard or impede correct inflation). Dry-side inflatables Secure your device to the ground by driving the stakes through the D rings of the anchor points. The stake must lean away from the inflatable. Leave no more than 25mm/1 inch of the top of the anchor stake exposed. All components of the anchor system MUST bear a force of 165kg as an absolute minimum, without straining, moving or breaking. This includes anchor stakes, D rings, ropes, ballast ANY element used to anchor or tether the inflatable. Maximum Number of Users The centre s Normal Operating Procedures should detail the maximum number of people and age ranges allowed on the structure at any one time, which in part will be determined by supervision levels. It is good practice to provide specific sessions for set age groups. It is inadvisable to have sessions where the ages and/or sizes of the children differ greatly. Use Only The Fan(S) Supplied With Your Unit. Please only use the fans(s) we have supplied with your unit. If you use a different fan, you do so at your own risk; this is not recommended. On inflatables that are PIPA registered, Airspace will provide number of users and height of users. These details will be found on the label on the front of your structure. Airspace can also provide guidance on other non-pipa equipment. Please call us for this information

26 Dry-side inflatables Rules of play Users should not be permitted to wear shoes on the structures, but they must wear socks. This is particularly important to avoid the possibility of friction burns, particularly where the structure features a slide. Users should remove jewellery, spectacles, sunglasses, watches, hard objects and other metallic objects that may cause tears or injury to themselves or another user. If locker keys are worn care should be taken to ensure that the key is retained completely within its plastic strap. Children should not be allowed to play in a boisterous manner that is likely to cause harm to themselves Cleaning and drying: Supervision Arrangements The risk assessment should detail the number of staff required to safely supervise the structure(s). Consideration will need to be given to the age of users, the maximum numbers permitted in the session and on the structure at any one time. The staff requirements should be detailed in the centres Normal Operating Procedures. Cleaning, Drying, Deflating and Re-Packing Dry-side inflatables or others. Users must not pull or swing on the tethering ropes, nor attempt to lift the structure in an attempt to dislodge others. It is essential that the highest standards of hygiene be maintained on all structures used by young children. The structure should be vacuumed to remove dust after use and cleaned with an anti-bacterial solution. It should then be allowed to dry. Users must not climb or hang on the outside walls of the structure or boom. Users must not be allowed to bounce on the front step of the structure, to enable safe and clear access and egress for the other users. Adults must not use the structure, unless it has been designed and manufactured expressly for this purpose. Safety mats should be positioned at the front of the structure, 3cm minimum in thickness. Place the mats around the safety step or egress, to a distance of 1.2m around any open side of the inflatable. An Anti-Static silicone based polish can also be applied to maintain the slippery surface on slides, but should NOT be applied to areas where sure footedness is required (e.g. at the entrance step). For structures including ball ponds, particular care is necessary. Immediate cleaning is required after urinations, defecation, and vomiting or blood spillage. In these circumstances the area should be cleared immediately and the balls and structure immersed in a strong disinfectant solution. Any damaged balls should be discarded. The balls should be allowed to dry. It is important that the product is allowed to dry after use

27 Dry-side inflatables Deflating: Ensure the inflatable and surrounding area is free of anyone not involved in the deflation and packing procedure. Turn off the blower. Remove the blower from the product, by undoing the strap that secures the inlet tube to the blower cone. Undo all the deflation zips, generally located in the back and/or sides of the inflatable and allow all the air to escape. Re-Packing: The structure should be re-packed in its original bag for storage. Storage: Once deflated and packed, your inflatable should be stored in a dry place. If structures are stored externally or in low temperatures, they should be brought into the area where they are to be used in advance and the structure allowed to acclimatise before inflation. Cold temperatures cause the material to become brittle. Structures should not be stored in less than 4 C. Failure to allow acclimatisation to take place will result in damage to the structure. The Manual Handling Assessment, undertaken prior to use, should detail how the product is to be moved and how many staff are required to carry out this task. Inspection and Maintenance Requirements Prior to Use The product should be inspected prior to each use. Check all of the following: The condition of the anchorage points on the structure. Ropes used for tethering are fastened securely and are not worn or chaffed. Check the structure for wear and rips in the fabric, particularly on the main bouncing surfaces, between the walls and towers and walls and bouncing areas. Check the fabric around the blower connection point. Check the correct blower specified for the device is being used and that the air pressure is sufficient to maintain the required firmness to give reliable and firm footing. Investigate any areas that appear to be not inflating correctly. The integrity of the blower including appropriate secured guards over the air inlet and outlet. The blower/inflation tube connection is in good condition and is firmly attached to the blower. The blower is positioned correctly, adequately protected and guarded and is not causing a tripping hazard. The condition of the electrical system, including the integrity of the electrical contacts, electrical cables, plugs, sockets and switches. The product should not be used until any defects identified have been rectified. The unit comes with a 12 month warranty but we also provide repair kits which enable you to carry out minor repairs on site, thus reducing down time. Dry-side inflatables

28 Dry-side inflatables Minor Repairs To repair a small puncture, make sure the area is clean and dry. Prepare a suitably sized PVC material patch from the patching kit supplied we recommend that you cut this with rounded corners to help it remain in place and that no sharp edges are present. Apply the glue supplied to the area around the puncture and to the back of the patch. Allow to become tacky. Fit the patch and apply moderate pressure, leaving to set for 12 hours. Ensure that the patch is securely fixed to the product before re-use. Take care to ensure that this activity is carried out in a well-ventilated dry area. If you require repairs, service or maintenance to the electrical blower, this must be carried out by a trained, appropriately qualified and competent person. Annual Inspections All Inflatables should be inspected annually by a qualified company. Airspace can carry out PIPA inspections and provide inspection certificates contact us on the anniversary of your product. On-site inspections are available. Dry-side inflatables 53 54

29 Atlantis inflatables Atlantis range operation instructions These instructions are provided specifically for the Atlantis range of pool inflatables provided by Airspace Solutions. Description The Atlantis range is a set of individual sealed obstacle beds that join together to make challenging obstacle courses in various shapes. They are interchangeable making several layouts from the same sections. These products are sealed and require inflation by a hand held fan that is supplied by Airspace Solutions with the product. All products on our Atlantis range from Airspace Solutions have been manufactured in line with EN The blower must be connected to a supply voltage corresponding to the electrical rating of the blower as indicated. Unplug the blower before moving. Residential current circuit breakers (RCCBs) should be tested daily by operating the test button, or if used less than once a day, tested every time they are used. Do not operate with a damaged supply cord or plug, after it malfunctions, or after it has been damaged in any way. Safe use of Electrical Blower The following precautions should be taken, as a minimum, to ensure safe use of the electrical blower: Do not overload electrical outlets beyond their capacity as this can result in fire or electrical shock. Atlantis inflatables Do not alter the attachment plug. The plug is configured for the appropriate electrical supply. Never put objects into the ventilation holes on the blower unit. Safety Do not spill liquid of any kind on the blower. Blowers must be situated a minimum of 2m away from the basin area The Atlantis range is manufactured to the highest quality and complies with required EU standards. Airspace Solutions always insists on a site consultation prior to purchase to ensure safe operation. Operation & risk assessment must be carried out prior to use by site management. This is the responsibility of the operator NOT Airspace solutions. On-site training can be provided to assist with this. Please refer to Pool inflatables section for list of hazards. Electrical cables must be safely routed out of the way and taped down if necessary Any electrical device supplied as part of your order should under no circumstances be used near water. Operators should carry out their own on site risk assessment and produce guidelines on safe use of electrical equipment. Always use the inflation point furthest from water 55 56

30 Atlantis inflatables Inflating Atlantis Range Each section must be rolled out and the fan supplied attached to the grey inlet. The grey screw top must be turned to remove, leaving it attached by the string. The inlet screw is then visible, this can be pushed in and turned to open the valve. The operator can then attach the pipe to the end of the fan marked Inflate and then twist in the opposite end of the pipe to the grey valve on the inflatable. Once this is securely in place the fan can be turned on to inflate. It may be necessary to hold the pipe in place for inflation. You will have been supplied with a manometer for measuring the pressure in each section. Insert this in to the inflation valve, in a similar manner to the inflation pump, in order to measure the pressure. The correct pressure is displayed on the safety label of each unit. If this information has worn off or is hard to read refer to the table below or contact Airspace Solutions. Positioning, Securing and clearance from poolside Current UK guidance suggests a minimum of 2m clearance from hard surfaces for all sealed inflatables. These particular units are used more in the style of a constant flow Aquarun inflatable and therefore Airspace would suggest, where possible, operators try to increase this distance to 2.5m in line with current Aquarun guidance. The operation and risk assessment is the responsibility of the operator/site management and the decision will ultimately be theirs. In consideration of this, other safety measures like Buoyancy jackets, type of users and pool design will be factors. 25m 2.5m clearance area Atlantis inflatables Be aware that changes in temperature, conditions and environment can greatly affect the pressure in an inflated section. Pressures that are measured as being within the tolerances (0.6 psi to 0.9psi) in cold conditions can increase significantly in warmer conditions. Regularly check the pressures and inflate/ deflate accordingly, and allow for the anticipated or forecast conditions. As a precaution, always inflate to the lower pressure tolerance. For example, the pressure in a unit inflated in the colder morning air will greatly increase as the ambient temperature increases later in the day, or if the inflated section is left in direct sunlight. Please refer to the table on page 65 and to the safety label printed on to each section for the minimum pressure necessary. 2.5m clearance area Lane Swimmng Lane Swimmng Lane Swimmng Set up example m 7m 5.5m Slide Exit

31 Atlantis inflatables Joining and Anchoring Atlantis Range To minimise the hazards all products must always be securely anchored. There are 8 steel D rings on each section in the Atlantis range. On each end there are 2 D rings on the side that are used for joining the sections with the bungee tension strap provided. There is a steel carabiner clip that easily clips through each D ring. Once this is secure the large Velcro strap can be positioned in place to hold the sections together. Care must be taken to make sure the Velcro is covered by the strap and that the ends are pushed down with the rounded soft edge facing down. Depending on the size of the total set up some staff may be required to get into the pool to join the final sections. As a rule, Airspace Solutions trainers and designers will try to avoid this and make sure that units can be set up from poolside without the need for pool entry. Bungee straps will be provided with each section. Depending on the pool design extra rope may need to be attached to D rings to secure to the pool side. In some pools or when using in outdoor bodies of water, weights may need to be used to anchor sections down. These can be provided with changeable straps to adjust to depths where required. Advice will be given on anchoring during consultation. Operator must seek advice from Airspace if there are issues with tethering. Please make sure all ropes used for tethering are visible and not tensioned too tightly. Maximum Numbers/Weight and Height of User There is no upper or lower age or height limit of user for the Atlantis range. Anybody can use the products as long as operation is managed in a safe manner. Rough horseplay is advised against and additional buoyancy maybe required for non-competent swimmers. User numbers need to be determined by the style of session and shape of the set up. For straight set ups Airspace Solutions would advise operation be the same as an Aquarun session where a flow of users be monitored. This typically has users queuing for their turn to run across the obstacles. The numbers in the session typically fluctuate between 40 to 90 people. For more complicated set ups the session may be run as a set number that play on the set up at one time. This can be controlled by groups of users being allowed onto the unit then making their way around the various obstacle sections. The maximum number should be taken from pool bather loads and lifeguarding provisions. Access on to all the set ups must be monitored and controlled and safe exit must also be monitored. Water Depth Current UK guidance suggests a depth of for sealed inflatables and for the non-slide end of Aquaruns. Where the structures are particularly large, i.e. slides or high obstacles, a depth of 1.5m is required. Airspace Solutions suggest operators apply this guidance to the Atlantis range and seek advice from Airspace Solutions when considering which sites to use the Atlantis product at. Each section has a suggested water depth for usage on an information patch located on each module and is also listed in the chart on page 65. Buoyancy jackets are advised for some Atlantis set ups and advice will be given following site visits. Lifeguarding must be considered during site risk assessment. Velcro connector strips Atlantis inflatables

32 Atlantis inflatables Safe use points For use by proficient swimmers only. Always supervise in use and carry out an on-site risk assessment prior to use. Users must listen to instructions from supervisors at all times. Do not swim underneath the unit. Users should not be permitted to wear shoes and should remove jewellery, watches, hard objects, etc. that may cause damage or injury. If locker keys are worn care should be taken to ensure that the key Check and maintain at least minimum operating pressures of all sections. Refer to the label printed on each section. Do NOT use in rough seas. Inspect all units before each use and carry out repairs as required. This is NOT a life saving device. Do NOT use in winds stronger than Beaufort force 5 (24mph/38kph). Atlantis inflatables is retained in the plastic holder. Do NOT tow. Users should be prevented from playing in a boisterous manner which is likely to cause harm to Ensure covers are always in place over inlet valves. themselves and others. Do not jump on to hard surfaces or any other surface from the unit. Diving from the inflatable should be dissuaded. Always anchor securely and check anchors throughout use. Users must not swing or pull on the tether ropes. Do not use in darkness. Do not use in shark infested waters or any other dangerous marine life areas. Always check ceiling heights. Always check surrounding areas are clear above and below the water surface

33 Atlantis inflatables Use outdoors The Atlantis range can be used outdoors. Operators must pay special attention to tethering, water depths and wind speed. Do Not Operate In High Winds. If the wind speed is, or is forecast to be, 24mph (38kph, Beaufort 5) or over, on the day you are operating DO NOT use your inflatable. We strongly recommend that you consult a recognised and reliable weather forecasting service before intending to set up your inflatable and throughout the day. A small, hand held anemometer (devise for measuring wind speed) is useful to carry with you on all occasions. An anemometer should be used for correct readings. Visible tether points should be used so users can see guide ropes when using the equipment. If weighting to the floor make sure that the weights are properly grounded and not on other objects not seen under the water. Carefully measuring of depths should be carried out prior to use and tidal changes should be considered when using in the sea. Further safety measures for buoyancy should be implemented if prior risk assessment proves it necessary. Cleaning, Drying, Deflating and Re-packing Cleaning: When the unit is removed from the water a fresh water hose down is suggested to remove the pool water and residue from users. If they sections can be tipped to allow this water to run off or dried with towels after use this will add to the clean storage. At points during the year it will be advisable to carry out a clean with a soft brush and solution of weak disinfectant. Third party cleaning chemicals are available and discussion with Airspace Solutions for more information is welcome. Leaving the sections wet in storage will result in staining and should be avoided. Deflating: Once safely out of the water the grey cap can be screwed off and the internal pressure screw can be pushed in and turned to hold the valve open to release air. The sections will go down a certain amount by just doing this but to properly pack the units the fan must be used. At the opposite end of the fan is the connection mark deflate. The pipe should be attached to this side of the fan and attached safely to the inlet on the section as instructed when inflating. Once this is secure the fan can be turned on and will suck out the air. Once the unit is completely deflated the fan can be turned off and the unit folded and rolled away. The strap that goes around the unit should be used to keep it together and each section will go back into its own bag. Atlantis inflatables The bags can be stored on top of each other in storage. The weight of each bag will be between 25 80kg. We suggest the heaviest be stored at the base

34 Atlantis inflatables Product guidelines for user weight capacity, water depth & minimum pressure Max weight of users (All modules) Min Pressure (PSI) (All modules) Max Pressure (PSI) (All modules) 400kg Product guidelines for user weight capacity, water depth & minimum pressure Product Code Product Name Minimum depth Product Code Product Name Minimum depth Product Code Product Name Minimum depth JU-6001 JU-6002 JU-6003 JU-6004 JU-6005 JU-6006 JU-6007 JU-6008 JU-6011 JU-6012 JU-6013 JU-6014 JU-6015 JU-6016 JU-6017 JU-6018 JU-6019 JU-6020 JU-6021 JU-6022 Basher Wall Platform Start Platform Corner Platform Demolition Tribeam (open bed) Mangle Wipeout Wall Cage (open bed) Hump Double Demolition Challenge Hump & Slide Dual Slide Splash Slide Drop Slide Giant Slide Slip Away S-Bend Bubbles Platform (4-sided) 1.2m 1.2m 1.2m 1.2m 1.5m 1.5m 2.0m 2.0m 3.0m 1.2m 1.2m 1.2m JU-6023 Cage (closed bed) 1.2m JU-6024 JU-6025 JU-6026 JU-6027 JU-6028 JU-6029 JU-6030 JU-6031 JU-6032 JU-6033 JU-6034 JU-6035 JU-6036 JU-6037 JU-6038 JU-6039 JU-6040 JU-6041 JU-6042 JU-6043 JU-6044 Tri-Beam (closed bed) Platform (2-sided) Platform (3-sided) Light House Giants Causeway Ladder Trampoline Stack Log Swing Bubble Pad Basher Pad Flipper Corner T-section Start Arch Cliff Hanger Half Ladder Roller T-Junction 4000 X-Junction 4000 Super Dome 1.2m JU-6045 Hopscotch JU-6046 Balance Beam 1.5m JU-6047 Climbing Tower 2m 1.2m JU-6048 Slide or Drop 2m 1.2m JU-6049 Tri-Climb 2m JU-6050 Twin Climb & Slide 2m 1.2m 2.0m 1.2m 1.5m 1.2m 1.5m 1.5m 1.2m 1.5m JU-6051 JU-6052 JU-6053 JU-6054 JU-6055 JU-6056 Lifeguard Tower T-Ramp X-Ramp Banked Corner Hopscotch (Drop-Stitch) 10m Bed N/A 1.2m Atlantis inflatables

35 office: +44 (0) Warranty Information Your product carries a 12 month warranty against faulty materials and manufacturing defects. This warranty only applies provided the product is used in accordance with these operating instructions and is used only for its intended purpose. This warranty is invalid if the product is misused or if the product is not returned suitably packed in a bag. In the unlikely event that anything should go wrong with your product, please contact Airspace for advice. WARRANTY: IMPORTANT Please confirm receipt of this instruction manual by sending an , stating your business or site name and product purchased, Airspace Solutions.com ltd. Registration in England & Wales No : Registered office address: Unit 17, Tafarnaubach Ind Est, Tredegar, Blaenau Gwent, NP22 3AA, UK

Attaching the ball Attach the rope to the underside of the middle of the inflatable. The rope will then attach to the ball using a D-ring.

Attaching the ball Attach the rope to the underside of the middle of the inflatable. The rope will then attach to the ball using a D-ring. General info 29 x29 x13 1 operator required 4 players max at one time Max weight per person 225lbs Minimum height 44 maximum height 80 2 x 1.5 hp blower WRECKING BALL Setup Unroll the inflatable onto a

More information

Risk Assessment For : Ace Tones Entertainments Ltd

Risk Assessment For : Ace Tones Entertainments Ltd Assessment Name: Bungee Run Assessment Type: General Assessor Name: Lewis Slack Affected Site(s): Assessment Date: 29/05/2017 Review Period: Annually Approved By: Lewis Slack Review Date: 29/05/2018 Approved

More information

WATER SLIDE. Limbo Beach

WATER SLIDE. Limbo Beach 84694 Limbo Beach WATER SLIDE IMPORTANT SAFETY INSTRUCTIONS. PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE SETUP AND USE. KEEP THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE. FOR AGES 5-12 ADULT

More information

68 MEGA OBSTACLE COURSE

68 MEGA OBSTACLE COURSE 68 MEGA OBSTACLE COURSE General info 68 x13 x16 1-2 operator(s) required 4 passengers max at one time 2 at the start line and 2 going over big slide Max weight per person 225lbs Minimum height 36 2 x 1.0

More information

IMPORTANT SAFETY INSTRUCTIONS. PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE SETUP AND USE. KEEP THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE

IMPORTANT SAFETY INSTRUCTIONS. PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE SETUP AND USE. KEEP THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE 31562 Spray N Splash ELEPHANT POOL IMPORTANT SAFETY INSTRUCTIONS. PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE SETUP AND USE. KEEP THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE. FOR AGES 3+

More information

OWNER S MANUAL AirTop Large and AirTop Small

OWNER S MANUAL AirTop Large and AirTop Small It is the owner s responsibility to read and understand the material presented in this manual and to instruct all users or operators on how to use product safely. By inflating the product, you hereby agree

More information

Zip-Line Kit Instructions

Zip-Line Kit Instructions 1 Zip-Lines Ireland - Zip-Line Kit Instructions DC001A Zip-Line Kit Instructions Thank you for your purchase of the ZLI Zip-line kit! This product was engineered to provide safe fun for all ages when the

More information

Guidance Bouncy Castles

Guidance Bouncy Castles Guidance Bouncy Castles 1. Introduction This guide is intended to provide guidance for local authority employees hiring; purchasing and/or using bouncy castles. It is also intended for operators, attendants

More information

NO FLIPPING NO HEAD FIRST 4 TO 7 PASSENGERS AT A TIME

NO FLIPPING NO HEAD FIRST 4 TO 7 PASSENGERS AT A TIME CASTLE BOUNCE HOUSE General info 15 x15 x13 1 operator required 4-7 passengers max at one time (depending on age and passengers size) Max weight per person 150lbs Minimum height 36 maximum height 60 1

More information

SERVICE & MAINTENANCE MANUAL FOR:

SERVICE & MAINTENANCE MANUAL FOR: SERVICE & MAINTENANCE MANUAL FOR: Tube Arch by: 2880 Interstate Parkway Brunswick, OH 44212 PH: 330-273.3200 Fax: 330-273-3212 Scherba Industries, Inc. 2011 Tube Arch INTRODUCTION INTRODUCTION To the owner:

More information

Island Hopper Gator Monster Head & Tail Water Trampoline Attachments

Island Hopper Gator Monster Head & Tail Water Trampoline Attachments Island Hopper Gator Monster Head & Tail Water Trampoline Attachments Aqua Sports Technology 11859 Lakeshore North, Auburn, CA 95602 530 268-7310 www.watertrampolines.com Table of Contents Introduction.....2

More information

TABLE OF CONTENTS. Hello! Happy Paddling, SAFETY WARNING WHAT S INCLUDED IN YOUR BOX GENERAL USE INFORMATION INFLATION INSTRUCTIONS FIN INSTALLATION

TABLE OF CONTENTS. Hello! Happy Paddling, SAFETY WARNING WHAT S INCLUDED IN YOUR BOX GENERAL USE INFORMATION INFLATION INSTRUCTIONS FIN INSTALLATION Hello! Thank you for purchasing an inflatable stand up paddle board and WELCOME TO THE TEN TOES FAMILY! We are a small team of outdoor adventurers who strive to make paddle boarding as enjoyable and fulfilling

More information

Owner s Manual. Water Sports Equipment

Owner s Manual. Water Sports Equipment Owner s Manual Water Sports Equipment Introduction Thank you for purchasing a RAVE Sports Whoosh products. This Owner s Manual is presented to enhance your enjoyment of the sport and is intended to alert

More information

Spray N Splash JUNGLE FUN POOL

Spray N Splash JUNGLE FUN POOL 23188 Spray N Splash JUNGLE FUN POOL IMPORTANT SAFETY INSTRUCTIONS. PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE SETUP AND USE. KEEP THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE. FOR AGES

More information

SLIDE. Super Sweet. instruction manual SLIP SLIDE SPLASH INFLATE THE FUN WITH THINGS YOU NEED TO KNOW ABOUT THE SUPER SWEET SLIDE.

SLIDE. Super Sweet. instruction manual SLIP SLIDE SPLASH INFLATE THE FUN WITH THINGS YOU NEED TO KNOW ABOUT THE SUPER SWEET SLIDE. Super Sweet instruction manual INFLATE THE FUN WITH THINGS YOU NEED TO KNOW ABOUT THE SUPER SWEET. SLIP ALWAYS read, understand and follow all warnings and instructions before use. Keep for future reference.

More information

Pontoon Slide Owner s Manual

Pontoon Slide Owner s Manual Pontoon Slide Owner s Manual Introduction Water sports can be safe and fun for all levels of enthusiasts. The Owner s Manual is presented to enhance your enjoyment of the sport. It is intended to alert

More information

Inflatable Dock Slide Owner s Manual

Inflatable Dock Slide Owner s Manual Inflatable Dock Slide Owner s Manual Introduction Water sports can be safe and fun for all levels of enthusiasts. The Owner s Manual is presented to enhance your enjoyment of the sport. It is intended

More information

Jumping Jack Inflatables, Operations Manual Constant air (continuous air flow) Aquatic/Pool/Waterborne inflatables (WBI)

Jumping Jack Inflatables, Operations Manual Constant air (continuous air flow) Aquatic/Pool/Waterborne inflatables (WBI) PAGE 1 of 12 Jumping Jack Inflatables, Operations Manual Constant air (continuous air flow) Aquatic/Pool/Waterborne inflatables (WBI) Introduction This operations manual has been compiled by Mr Jay A Maxwell

More information

B.C.D. Buoyancy Compensator Device User Manual

B.C.D. Buoyancy Compensator Device User Manual B.C.D. Buoyancy Compensator Device User Manual English ver 2.2 CONTENTS Important Warnings Preparation before diving - How to assemble the retaining rubber bungees - How to assemble the tank straps - How

More information

Floor Mount Socket. T: +44 (0) F: +44 (0)

Floor Mount Socket. T: +44 (0) F: +44 (0) G-Davit : Floor Mount Socket USER INSTRUCTION MANUAL A davit socket for installation bolted to a high strength flooring material. Suitable for both fall arrest use and lifting. EN795 Class B, PPE Anchor

More information

Chapter 2 Rigging. Cutting Wire Rope. Anchoring Wire Rope to Drum. Winding Wire Rope Onto Drum

Chapter 2 Rigging. Cutting Wire Rope. Anchoring Wire Rope to Drum. Winding Wire Rope Onto Drum Chapter 2 Rigging Cutting Wire Rope The wire rope must be tightly seized on both sides of the point where the wire rope will be cut, as shown in Figure 2-1. Seize the wire rope with either seizing wire

More information

Operator s Manual. with Maintenance Schedule. Fourth Edition Second Printing Part No

Operator s Manual. with Maintenance Schedule. Fourth Edition Second Printing Part No Operator s Manual with Maintenance Schedule Fourth Edition Second Printing Part No. 82297 Operator s Manual Fourth Edition Second Printing Important Read, understand and obey these safety rules and operating

More information

12 Saturn Owner s Manual

12 Saturn Owner s Manual 12 Saturn Owner s Manual Water Sports Equipment Inflation, set up and supervision must be done by a mature and knowledgeable adult! Inspect product for any unsafe conditions before use! Do not use if repair

More information

PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING!

PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING! PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING! Read and understand instructions before using Petersen Plugs. Failure to comply may result in property damage, serious

More information

CONTENTS AIRBERTH OWNER S MANUAL I 3

CONTENTS AIRBERTH OWNER S MANUAL I 3 CONTENTS 1 Introduction...4 2 Suitable Mooring Locations...5 3 Operating Procedures...6 3.1 Safety Checklist...6 3.2 Store your Boat with AirBerth...7 3.3 Launch your Boat with AirBerth...8 3.4 Hull Rinsing

More information

It s time to take your water adventure to the next level, find true paradise, and bring family and friends with you! Every ParadisePad is designed

It s time to take your water adventure to the next level, find true paradise, and bring family and friends with you! Every ParadisePad is designed OWNERS MANUAL 2 It s time to take your water adventure to the next level, find true paradise, and bring family and friends with you! Every ParadisePad is designed with care and a vision that each owner

More information

GUIDELINES FOR USE GUARD

GUIDELINES FOR USE GUARD GUIDELINES FOR USE GUARD G Guard Range of Load Arrestors Retractable Fall Arrest Safety Line for Protection of Machinery & Sensitive Loads GLOBESTOCK MILE OAK INDUST. ESTATE, MAESBURY ROAD, OSWESTRY, SHROPSHIRE

More information

PF30 Inspection & Maintenance Manual

PF30 Inspection & Maintenance Manual PF30 Inspection & Maintenance Manual Version 1.4 (September 2011) 1 Contents 1. Warning!!!!!!!!!! 3 2. Terminology! Figure 1: POWERFAN PF30 and Drope!!!! 4! Figure 2: POWERFAN PF30 with belt guard retracted!!

More information

Rapid Response Shelters. Rubber Product Manual

Rapid Response Shelters. Rubber Product Manual Rapid Response Shelters Rubber Product Manual 1 Index Technical Data Parts List Materials List Operational Instructions Packing Maintenance & Procedures Repairs & Storage 3 4 5 6 8 10 11 WARNING: Carefully

More information

PIRATE SHIP. Ahoy Matey

PIRATE SHIP. Ahoy Matey 59073 Ahoy Matey PIRATE SHIP IMPORTANT SAFETY INSTRUCTIONS. PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE SETUP AND USE. KEEP THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE. FOR AGES 5+ ADULT

More information

DO NOT use any Alien Flier Zip Line Products or Accessories until you read and understand these SAFETY WARNINGS!

DO NOT use any Alien Flier Zip Line Products or Accessories until you read and understand these SAFETY WARNINGS! ! WARNING DO NOT use any Alien Flier Zip Line Products or Accessories until you read and understand these SAFETY WARNINGS! A zip line can be very dangerous. Do not use this kit if you do not understand

More information

Pontoon Slide Owner s Manual

Pontoon Slide Owner s Manual Pontoon Slide Owner s Manual www.ravesports.com Table of Contents Introduction... 2 Safety rules and information... 3 Boat compatibility guide.5 Assembling and using your Pontoon Slide... 6 Cleaning and

More information

KERSPLASH POOL CLIMBING WALL INSTALLATION INSTRUCTIONS

KERSPLASH POOL CLIMBING WALL INSTALLATION INSTRUCTIONS TOLL FREE: 1-800-476-7366 VOICE 651-665-9131 FAX 651-665-9130 EMAIL: INFO@POOLCLIMBINGWALLS.COM EVERLAST CLIMBING 1335 MENDOTA HEIGHTS ROAD MENDOTA HEIGHTS, MN 55120 2012 EVERACTIVE BRANDS Congratulations!

More information

SPUD OWNER S MANUAL ALWAYS WEAR A COAST GUARD APPROVED FLOTATION DEVICE WHEN OPERATING THE SPUD KAYAK.

SPUD OWNER S MANUAL ALWAYS WEAR A COAST GUARD APPROVED FLOTATION DEVICE WHEN OPERATING THE SPUD KAYAK. SPUD OWNER S MANUAL ALWAYS WEAR A COAST GUARD APPROVED FLOTATION DEVICE WHEN OPERATING THE SPUD KAYAK. Know the limits of your abilities and the limits of your equipment. Changes in air temperature and

More information

Pontoon Slide Owner s Manual

Pontoon Slide Owner s Manual Pontoon Slide Owner s Manual WWW.RAVESPORTS.COM Copyright 2018 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including

More information

Fall Control User Instructions

Fall Control User Instructions Fall Control User Instructions Procedure BP-FCL-0096-01 branach.com sales@branach.com User Instructions These user instructions cover the following Branach products classified as for Professional use according

More information

Blue Whale Spa :- Site Preparation and Delivery

Blue Whale Spa :- Site Preparation and Delivery Pre-Delivery Instructions Please take the time to read this information carefully, as it will provide you with the information you will need to ensure the safe, secure, and timely installation of your

More information

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST OIL-LESS TYPE IMPORTANT: PLEASE READ CAREFULLY BEFORE STARTING OPERATIONS. THE CONTENTS ARE FOR GENERAL INFORMATION OF ALL THE SIMILAR MODELS. Record

More information

ANNUAL SELF INSPECTION / SERVICING INSTRUCTION SHEET

ANNUAL SELF INSPECTION / SERVICING INSTRUCTION SHEET ANNUAL SELF INSPECTION / SERVICING INSTRUCTION SHEET These instructions relate ONLY to the following models of inflatable PFD s: Watersnake Inflatable PFD & Watersnake Deluxe PFD (ADULT AND CHILDRENS SIZES)

More information

1.2 LIMITATIONS: Consider the following application limitations before using this equipment:

1.2 LIMITATIONS: Consider the following application limitations before using this equipment: User Instruction Manual Standing Seam Roof Anchor This manual is intended to meet the Manufacturer s Instructions, and should be used as part of an employee training program as required by OSHA. Figure

More information

Pectoral Machine. User manual E S S E N T I A L S T R E N G T H

Pectoral Machine. User manual E S S E N T I A L S T R E N G T H E L E M E N T and the cable E S S E N T I A L S T R E N G T H User manual 1 and the cable and The identification plate of and manufacturer, affixed on the back panel of the weight stack, gives the following

More information

Cimarron Pontoon Boat

Cimarron Pontoon Boat The Cimarron Pontoon Boat O W N E R ' S M A N U A L C I M A R R O N P O N T O O N B O A T O W N E R S M A N U A L T A B L E O F C O N T E N T S INTRODUCTION 4 SAFETY INFORMATION AND SYMBOLS 5 RESPONSIBILITIES

More information

Owner s Guide. ElevateSUP.com

Owner s Guide. ElevateSUP.com Owner s Guide ElevateSUP.com IMPORTANT READ THIS IMPORTANT INFORMATION BEFORE USING YOUR STAND UP PAD- DLEBOARD Disregarding any of the safety precautions and instructions contained in the owner s manual

More information

Sea Rebel Kayak Owner s Manual

Sea Rebel Kayak Owner s Manual Sea Rebel Kayak Owner s Manual www.ravesports.com Table of Contents Product instructions and warnings...2 Inflating instructions...3 Proper use.. 4 Deflating and storage.........6 Cleaning and troubleshooting...8

More information

CREWFIT 165 SPORT. self care and maintenance manual

CREWFIT 165 SPORT. self care and maintenance manual CREWFIT 165 SPORT self care and maintenance manual Crewsaver lifejackets must be serviced by an accredited service AGENT every 3 years. Please print and read the self care and maintenance instructions

More information

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS XR 9-2009:new odc 1018 revised 2/17/10 9:11 AM Page 1 ODC XR 9 OUTDOOR DISCOVERY CRAFT ASSEMBLY INSTRUCTIONS Your ODC XR 9 Pontoon Boat comes in two separate cartons consisting of the following parts:

More information

7130 Lancer Rear Drive Magnetic Commercial Indoor Cycling Bike

7130 Lancer Rear Drive Magnetic Commercial Indoor Cycling Bike 7130 Lancer Rear Drive Magnetic Commercial Indoor Cycling Bike Owner s Manual Made in Taiwan INDEX IMPORTANT SAFETY INFORMATION... 1 EXPLODED DRAWING... 2 PARTS LIST... 3 ASSEMBLY INSTRUCTION... 4-9 USER

More information

Products For The. Fire & Emergency Services. Cintec International Limited

Products For The. Fire & Emergency Services. Cintec International Limited Products For The Fire & Emergency Services Cintec International Limited Waterwall Isolation Units Acetylene Isolator Specifications: External Height External Width External Depth Internal Height Internal

More information

ASSEMBLY MANUAL HOBIE CATSY

ASSEMBLY MANUAL HOBIE CATSY ASSEMBLY MANUAL HOBIE CATSY HOBIE CAT EUROPE ZI Toulon Est, BP 50 8078 Toulon cedex 9, France Tel : + (0)9 08 78 78 - Fax : + (0)9 08 99 Email : hobiecat@hobie-cat.net - http://www.hobie-cat.net ASSEMBLY

More information

ROUND ASSEMBLY. Positioning

ROUND ASSEMBLY. Positioning ROUND ASSEMBLY Positioning To ensure maximum enjoyment and efficiency, consider the following steps when selecting the desired location of you pool. Select a location that receives maximum sunlight for

More information

Flat Fold Highchair INSTRUCTION MANUAL. Designed and manufactured to BS EN 14988: 2012 IMPORTANT:

Flat Fold Highchair INSTRUCTION MANUAL. Designed and manufactured to BS EN 14988: 2012 IMPORTANT: Flat Fold Highchair INSTRUCTION MANUAL Designed and manufactured to BS EN 14988: 2012 IMPORTANT: Thank you for choosing our product. Please read and understand these instructions before using this flat

More information

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289 3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS Item #31289 The EASTWOOD 3 GALLON, OILLESS PANCAKE COMPRESSOR, with an Integral Air Regulator, efficiently supplies all compressed air requirements for

More information

BANKSMAN / SLINGER. 1. What is the smallest size diameter of synthetic rope allowed for use as a hand held tagline?

BANKSMAN / SLINGER. 1. What is the smallest size diameter of synthetic rope allowed for use as a hand held tagline? BANKSMAN / SLINGER 1. What is the smallest size diameter of synthetic rope allowed for use as a hand held tagline? A. 16mm B. 10mm C. 12mm 2. What is the maximum temperature that a webbing sling can be

More information

Med Aire Alternating Pressure Pump and Pad System

Med Aire Alternating Pressure Pump and Pad System User Manual Med Aire Alternating Pressure Pump and Pad System 14002E 14001E Symbols & Statements NOTE Indicates some tips or some information users should be aware of. CAUTION Indicates correct operating

More information

T3200 TransPlate Harness

T3200 TransPlate Harness T3200 TransPlate Harness www.diverite.com Product Description The TransPlate Harness is designed specifically for use with hard back-plates, such as stainless steel or aluminum. The TransPlate Harness

More information

SEAGO LIFERAFT GX MODEL

SEAGO LIFERAFT GX MODEL SEAGO LIFERAFT GX MODEL OWNERS MANUAL & OPERATING HANDBOOK First steps 1. Register the liferaft to activate warranty at www.seagoyachting.co.uk/register or post the registration form provided. 2. Affix

More information

Storm Owner s Manual

Storm Owner s Manual Storm Owner s Manual www.ravesports.com Table of Contents Product instructions and warnings... 3 Water sports safety code... 8 Inflating instructions... 11 Troubleshooting... 12 Cleaning and storage...

More information

GROUP VISIT RISK ASSESSMENT

GROUP VISIT RISK ASSESSMENT GROUP VISIT RISK ASSESSMENT At Willows Activity Farm the Health and Safety of our visitors is our number one priority. We work with local and national experts as well as the local authority to constantly

More information

GAS STRUT SAFETY INFORMATION

GAS STRUT SAFETY INFORMATION VERSION 4.0 - PAGE 1 CONTENTS 1. SAFETY REQUIREMENTS 2. INSTALLATION 3. DO S AND DON TS 4. PERIODIC INSPECTION 5. SERVICE LIFE 6. FUNCTIONAL SAFETY 7. DAMAGED GAS STRUTS VERSION 4.0 - PAGE 2 SAFETY REQUIREMENTS

More information

Installation and Training Manual

Installation and Training Manual AirForce1 Tower Kit Installation and Training Manual FuturEnergy Limited Ettington Park Business Centre Stratford upon Avon CV37 8BT +44 (0)1789 451070 Table of Contents Safety Notes... 3 Parts Supplied

More information

VERTICAL AIR COMPRESSORS

VERTICAL AIR COMPRESSORS VERTICAL AIR COMPRESSORS MODEL NO: VE15C150, VE18C150, VE25C150 PART NO: 2226010, 2226020, 2226025 OPERATION & MAINTENANCE INSTRUCTIONS LS0715 INTRODUCTION Thank you for purchasing this CLARKE Vertical

More information

Suitability of Work Equipment

Suitability of Work Equipment These regulations came into effect on the 5th December 1998 and replace PUWER 1992. They cover almost all equipment used at work, including tool box tools such as hammers, knives etc. They also cover machinery

More information

Section 16B. Fall Protection. Falls are the second leading cause of death in the workplace. Factors contributing to falling incidents:

Section 16B. Fall Protection. Falls are the second leading cause of death in the workplace. Factors contributing to falling incidents: Section 16B. Fall Protection Falls are the second leading cause of death in the workplace. Factors contributing to falling incidents: 1. Personal factors Lack of concentration. Use of medication. Poor

More information

VANDAL SUP OWNER S MANUAL

VANDAL SUP OWNER S MANUAL IQ SURF IQ FREE IQ TOURING IQ RACE VANDAL SUP OWNER S MANUAL 1 Dear customer, Congratulations on your purchase of the board. We are proud to bring you a quality product at an affordable price with excellent

More information

Fiber Cable Puller with Tuf-Lugger lite

Fiber Cable Puller with Tuf-Lugger lite 7 OPERATING INSTRUCTION MANUAL Fiber Cable Puller with Tuf-Lugger lite Copyright 2015 DCD Design & Manufacturing Ltd. Revision 1.0 IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING The Fiber

More information

POLICY - GOALPOST SAFETY

POLICY - GOALPOST SAFETY Updated October 2013 POLICY - GOALPOST SAFETY 1. Introduction Australia as a nation loves all sports - both in a participatory and spectator capacity. Football s popularity at grassroots level is unrivalled,

More information

Product Name: Concrete Anchor Strap

Product Name: Concrete Anchor Strap Product Name: Concrete Anchor Strap Part #: 10705; 10710; 10715 ; 10717; 10720 Instruction Manual Do not throw away these instructions! Read and understand these instructions before using equipment! Table

More information

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment 1. Application Emergency eyewash and eye/face wash equipment are prescribed first aid installations for workplaces

More information

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064 AIR HAMMERS MODEL NO: CAT138/CAT139 PART NO: 3120152 /3120153 OPERATING & MAINTENANCE INSTRUCTIONS GC064 INTRODUCTION Thank you for purchasing this CLARKE Air Hammer. Before attempting to use this product,

More information

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT! Guardian Fall Protection Kent, WA 800-466-6385 www.guardianfall.com GENERAL SYSTEM SELECTION CRITERIA: Selection of fall protection shall be made by a Competent Person. All fall protection equipment shall

More information

POWER ASSISTED BICYCLES OWNERS MANUAL

POWER ASSISTED BICYCLES OWNERS MANUAL POWER ASSISTED BICYCLES OWNERS MANUAL WE HAVE INCLUDED A BICYCLE OWNER S MANUAL WHICH YOU SHOULD REFER TO FOR ALL GENERAL CYCLE MAINTENANCE. CONTENTS Page. 3 Unpacking. Page. 3-4 Easy steps to get started.

More information

The purpose of this training is to give field technicians awareness training and guidelines on potential hazards they may encounter in the field.

The purpose of this training is to give field technicians awareness training and guidelines on potential hazards they may encounter in the field. Purpose The purpose of this training is to give field technicians awareness training and guidelines on potential hazards they may encounter in the field. Fall Protection and Prevention JELD-WEN Field Employees

More information

User Instructions 1789 Parapet Wall Anchor

User Instructions 1789 Parapet Wall Anchor User Instructions 1789 Parapet Wall Anchor This manual is intended to meet the Manufacturer Instructions as required by ANSI Z359.1 and should be used as part of an employee training program as required

More information

February 2014 or following a significant change in information. Food Stall Guidance Note. Barbeque Guidance Note. Open Day Guidance Note

February 2014 or following a significant change in information. Food Stall Guidance Note. Barbeque Guidance Note. Open Day Guidance Note Safety and Health Services Document control information Published document name: inflatables-gn Date issued: February 2013 Version: 4.0 Previous review dates: 2005, 2008, 2010 Next review date: Related

More information

Semi Freddo Snow kite [Ram Air]

Semi Freddo Snow kite [Ram Air] User manual Semi Freddo Snow kite [Ram Air] This manual gives you detailed instructions on how to use your new Semi Freddo kite. We recommend you take your time to read the instructions. In case you have

More information

SASK-A-POLE OWNERS AND USERS MANUAL

SASK-A-POLE OWNERS AND USERS MANUAL SASK-A-POLE OWNERS AND USERS MANUAL GENERAL INFORMATION The Saskatchewan Abilities Council s Sask-a-Pole accessibility and transfer aid is designed to help provide safe and easy access to chairs, beds,

More information

MOOWII MANUAL. Using a kite is dangerous and can cause severe injuries. Before use, carefully read this manual.

MOOWII MANUAL. Using a kite is dangerous and can cause severe injuries. Before use, carefully read this manual. MOOWII MANUAL Using a kite is dangerous and can cause severe injuries. Before use, carefully read this manual. Release of liability By assembling or using this CrazyFly kiteboarding product (further named

More information

WARNING! ADULT ASSEMBLY ONLY

WARNING! ADULT ASSEMBLY ONLY POOL FENCE EXPANSION KIT Complies with Australian Standard, AS1926.1-2012: Safety barriers for swimming pools WARNING! ADULT ASSEMBLY ONLY PACKAGE CONTENTS: Part A - 1 x 30cm LONG POST SECTION Part B 1

More information

INSTRUCTIONS FOR THE 7FT REVOLVER 3-IN-1 MULTIGAMES TABLE

INSTRUCTIONS FOR THE 7FT REVOLVER 3-IN-1 MULTIGAMES TABLE INSTRUCTIONS FOR THE 7FT REVOLVER 3-IN-1 MULTIGAMES TABLE Please keep these instructions for future reference. Adult assembly required. This table is not a toy & is intended for use by or under the supervision

More information

Agilent 1220 Infinity II LC Mobile Upgrade Kit

Agilent 1220 Infinity II LC Mobile Upgrade Kit Agilent 1220 Infinity II LC Mobile Upgrade Kit Note 1220 Infinity II LC Mobile Upgrade Kit This note describes the procedures to install an Mobile Upgrade kit to an existing Agilent 1220 Infinity II LC.

More information

Pressure Relief Valve Instruction Manual

Pressure Relief Valve Instruction Manual CVR3-M0_062017 Pressure Relief Valve Instruction Manual MODEL: CVR3 SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 Tel: 888-332-6419 * Fax: 816-448-2142 E-mail: sales@bvahydraulics.com Website:

More information

Flexfence Swaging Unit. Product Manual. Release 02/16.

Flexfence Swaging Unit. Product Manual. Release 02/16. Product Manual www.ingalcivil.com.au 1.0 Safety Precautions 1.1 Personal Protection While operating this equipment it is recommended that the following personal protective equipment be worn; Long sleeve

More information

USER MANUAL

USER MANUAL C Cimarron Sports 1-888-816-6517 www.cimarronsports.com Combo Pitching Machine USER MANUAL TABLE OF CONTENTS Thank you for purchasing the Cimarron Combo Pitching Machine. The Cimarron Combo Pitching Machine

More information

Instant Garage 20' x 12' 3" x 8' 3"

Instant Garage 20' x 12' 3 x 8' 3 Instant Garage 20' x 12' 3" x 8' 3" Assembly Instructions Description Model # Instant Garage 20' x 12' 3" x 8' 3" - Grey CIG 1220 3503502 Recommended Tools OR THIS IS A TEMPORARY STRUCTURE AND NOT RECOMMENDED

More information

Instructions for Birth Pool in a Box

Instructions for Birth Pool in a Box Instructions for Birth Pool in a Box Thank you for purchasing Birth Pool in a Box! We aim to make the use of water for labour and birth accessible for all women. We hope you are able to enjoy the benefits

More information

Inflatable Product Owner s Manual

Inflatable Product Owner s Manual Inflatable Product Owner s Manual www.moonwalkusa.com Customer Name Game Type Invoice Number Serial Number Date of Purchase Ship/Pickup Date MoonwalkUSA. All rights reserved. Page 1 of 15 Inflatable Product

More information

IMPORTANT SAFETY NOTICE

IMPORTANT SAFETY NOTICE OWNER S MANUAL NOTE: Any photos of the YBIKE or decals in the owner s manual are intended to be used as a reference only, and there may be some differences to the unit you purchased. IMPORTANT SAFETY NOTICE

More information

Aqua Attachments Owner s Manual

Aqua Attachments Owner s Manual Aqua Attachments Owner s Manual Introduction Thank you for purchasing a RAVE Sports Aqua Attachment. Water sports can be safe and fun for all levels of enthusiasts. This Owner s Manual is presented to

More information

Part #: 15158; 15159; 15188; 61027; 61029; 61140; 61141

Part #: 15158; 15159; 15188; 61027; 61029; 61140; 61141 Product Name: Guardrail Receivers Part #: 15158; 15159; 15188; 61027; 61029; 61140; 61141 Instruction Manual Do not throw away these instructions! Read and understand these instructions before using equipment!

More information

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS AIR FILTER, REGULATOR AND LUBRICATOR 4035 ASSEMBLY AND OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com Copyright 004 by Harbor Freight

More information

Staff Contractors. Public. Staff Contractors

Staff Contractors. Public. Staff Contractors 1. Vehicle movements In conjunction with the vehicle driver, venue management and the client, our staff should ensure the safe parking of vehicles for loading and unloading purposes. Depending upon circumstances

More information

Halsey Taylor Owners Manual STOP!

Halsey Taylor Owners Manual STOP! Halsey Taylor Owners Manual 4710 Freeze Resistant Floor Mounted Steel Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4710FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY

More information

Specialists Window Cleaning Induction

Specialists Window Cleaning Induction Specialists Window Cleaning Induction Mobile Tower Scaffolds Mobile tower scaffolds are used on flat firm, stable ground to access higher levels. They have toe boards, mid rails & guard rails to prevent

More information

POOL FENCE STARTER KIT INSTALLATION MANUAL WARNING! ADULT ASSEMBLY ONLY DESIGNED FOR ASSEMBLY ON GRASS

POOL FENCE STARTER KIT INSTALLATION MANUAL WARNING! ADULT ASSEMBLY ONLY DESIGNED FOR ASSEMBLY ON GRASS POOL FENCE STARTER KIT Complies with Australian Standard, AS1926.1-2012: Safety barriers for swimming pools INSTALLATION MANUAL Pool not included DESIGNED FOR ASSEMBLY ON GRASS WARNING! ADULT ASSEMBLY

More information

INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008

INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008 INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008 0376/448/00 ISSUE 01 EMERGENCY PUSH PAD PULLMAN BOLT DEVICE TO EN 179 : 2008 1000mm MAXIMUM CLEAR OPENING HEIGHT WITH PUSH

More information

Poollift Delphin. Version: February, 2015 MANUAL AND OPERATING INSTRUCTIONS

Poollift Delphin. Version: February, 2015 MANUAL AND OPERATING INSTRUCTIONS Poollift Delphin Version: February, 2015 MANUAL AND OPERATING INSTRUCTIONS Content 1. Introduction... 3 2. Technical Specifications... 3 Used materials... 3 3. Installation Instructions... 4 Fastening

More information

Low Ropes and Adventure Course Risk Assessment

Low Ropes and Adventure Course Risk Assessment Low Ropes and Adventure Course Risk Assessment Activity Low Ropes and adventure course Activity Session What are the hazards? Inappropriate use and falling from the equipment Rope burns Over balancing

More information

User Instructions 1790 Rail Anchor

User Instructions 1790 Rail Anchor User Instructions 1790 Rail Anchor This document is intended to meet the Manufacturer s Instruction requirements as stated by ANSI Z359.1, and should be used as part of an employee training program as

More information

Product Name: 2-Way Standing Seam Roof Clamp

Product Name: 2-Way Standing Seam Roof Clamp Product Name: 2-Way Standing Seam Roof Clamp Part #: 10600 Instruction Manual Do not throw away these instructions! Read and understand these instructions before using equipment! Introduction 1 Applicable

More information

Inflatable Acoustical Shell

Inflatable Acoustical Shell Owner s Manual Inflatable coustical Shell CONTENTS Safety Precautions.............................2 Set Up and Usage.........................2 Stability..................................3 Fire Hazard...............................3

More information