1 Instruction manual Mini CORI-FLOW Compact Coriolis Mass Flow Meters/Controllers for Liquids and Gases Doc nr.: H Date: ATTENTION Please read this instruction manual carefully before installing and operating the instrument. Not following the guidelines could result in personal injury and/or damage to the equipment.

2 SCOPE OF THIS MANUAL This manual covers the general part of digital mini CORI-FLOW mass flow instruments for gases and liquids. It treats the general instructions needed for the instruments. More information can be found in other documents. Mini CORI-FLOW instruments have modular instruction manuals consisting of: - Short form instruction manual mini CORI-FLOW (document nr ) - General instructions mini CORI-FLOW (document nr ) - Operation instructions digital instruments (document nr ) - Fieldbus/interface description: - FLOW-BUS Interface (document nr ) - PROFIBUS-DP Interface (document nr ) - DeviceNet Interface (document nr ) - RS232 Interface with FLOW-BUS protocol (document nr ) - Modbus interface (document nr ) page

3 Even though care has been taken in the preparation and publication of the contents of this manual, we do not assume legal or other liability for any inaccuracy, mistake, mis-statement or any other error of whatsoever nature contained herein. The material in this manual is for information purposes only, and is subject to change without notice. Bronkhorst Cori-Tech B.V. June 2011 Warranty The products of Bronkhorst Cori-Tech B.V. are warranteed against defects in material and workmanship for a period of three years from the date of shipment, provided they are used in accordance with the ordering specifications and the instructions in this manual and that they are not subjected to abuse, physical damage or contamination. Products that do not operate properly during this period may be repaired or replaced at no charge. Repairs are normally warranted for one year or the balance of the original warranty, whichever is the longer. See also paragraph 9 of the Conditions of sales. The warranty includes all initial and latent defects, random failures, and undeterminable internal causes. It excludes failures and damage caused by the customer, such as contamination, improper electrical hook-up, physical shock etc. Re-conditioning of products primarily returned for warranty service that is partly or wholly judged nonwarranty may be charged for. Bronkhorst Cori-Tech B.V. prepays outgoing freight charges when any party of the service is performed under warranty, unless otherwise agreed upon beforehand. However, if the product has been returned collect to Bronkhorst Cori-Tech B.V., these costs are added to the repair invoice. Import and/or export charges, foreign shipping methods/carriers are paid for by the customer page 3

4 TABLE OF CONTENTS 1 INTRODUCTION General description Gas / Liquid flow Housing Valves Badger Meter Valves Liquid dosing systems with pumps Sensor measuring principle Mini CORI-FLOW sensor Valve principles Solenoid valve Vary-P valve Pilot operated valve Software for physical properties of gases and liquids (mini) Cori-Flow accuracy INSTALLATION Receipt of equipment Return shipment Service Mounting Notes for temperature considerations Fluid/gas connections Piping Electrical connections Pressure testing Supply pressure System purging Seals Equipment storage Electromagnetic compatibility Electro static discharge OPERATION General Power and warm-up Start-up Zeroing What is zero-stability? Procedure for zeroing Zero-procedure information Alternatives for starting zero procedure Zeroing with the Micro-switch Zeroing through the digital communication Operating conditions Manual operation Analog operation BUS / digital operation RS232 communication cable T-part MAINTENANCE General mini CORI-FLOW sensor Controllers Control valves Solenoid valves Vary-P valve Pilot operated valve K v -value calculation For gases For Liquids Calibration procedure Instrument re-ranging Instrument filter settings INTERFACE DESCRIPTION TROUBLESHOOTING...34 page

5 6.1 General Calibration check Troubleshooting summary general page 5

6 1 INTRODUCTION 1.1 General description Gas / Liquid flow The Bronkhorst Cori-Tech B.V. series mini CORI-FLOW mass-flow meter/controller for gases and liquids is an accurate device for measuring gas and liquid flows up to 200 bara depending on body rating, virtually independent of pressure and temperature changes. The mini CORI-FLOW is a real mass-flow meter/controller and measures the flow in mass, it does not matter what the properties of the gases or liquids are. The system can be completed with a control valve or a pump and flexible readout unit to measure and control gas and liquid flows. Mini CORI-FLOW series by Bronkhorst Cori-Tech B.V. are precise and compact Mass Flow Meters and Controllers, based on the Coriolis measuring principle. Designed to cover the needs of the low flow market, there are 4 models to overlap flow ranges from 5 g/h up to 300 kg/h (full scale values), each offering multirange functionality: factory calibrated ranges can be rescaled by the user, maintaining the original accuracy specs. The instruments are equipped with a robust IP65 weatherproof housing. Instruments of the mini CORI-FLOW series contain a uniquely shaped, single loop sensor tube, forming part of an oscillating system. When a fluid flows through the tube, Coriolis forces cause a variable phase shift, which is detected by sensors and fed into the integrally mounted pc-board. The resulting output signal is strictly proportional to the real mass flow rate. Coriolis mass flow measurement is fast, accurate and inherently bidirectional. The mini CORI-FLOW features density and temperature of the fluid as secondary outputs Housing Each instrument housing style incorporates several provisions to comply with EMC requirements. Also the instrument housing is a robust IP65 weatherproof housing. Meter housing M12-M14 Meter housing M15 Controller housing with metal seal valve page

7 1.1.3 Valves M12, M13 and M14 mini CORI-FLOW controllers are fitted with a fixed or modular valve. The M15 mini CORI-FLOW controller can only be equipped with a modular valve. Integrated valves for liquids and gases For liquids the valve has an extra purge adaptor on top for de-gassing. In case of a modular valve it is attached by means of a port connector. Possible combinations: M12 M13 M14 M15 Liquid C2I F-033CI C2I C5I F-033CI C2I F-033CI C2I C5I F-033CI F-004AI Gas C0I, C1I F-033CI C01, C1I C5I F-033CI C0I, C1I F-033CI C5I F-033CI F-004AI F-012AI, F-013AI Valves: C2I valve Direct operating valve for liquids ( open sleeve) metal sealed with purge connector. C2I valve = normally closed C5I valve Direct operating valve for liquid/gas metal sealed. C5I valve = normally closed page 7

8 C0I / C1I valve Direct operating valve for gases metal sealed C0I valve = normally closed C1I valve = normally open F-033CI valve Vary-P operating valve for liquid/gas elastomeric sealed F-033CI valve = normally closed F-004AI / BI valve Bellow valve for liquid/gas elastomeric sealed F-004AI/BI valve = normally closed F-012AI/F-013AI valve Pilot operated valve for gases elastomeric sealed F-012AI/F-013AI valve = normally closed page

9 1.1.4 Badger Meter Valves For those special applications where the Bronkhorst valves do not meet the specifications anymore we can use Badger Meter valves as a good alternative. Reasons for using an alternative valve could be requirements for: - Higher maximum pressure or delta-pressure - Higher Kv-values - Higher or lower temperatures - Faster response time - Metal sealed (e.g. for supercritical gases like CO2 or ethylene) Badger Meter offers a wide range and variety of valves. These membrane valves are operated indirectly using an I/P-converter with compressed air. The I/P-converter is connected to the controller output of the mini CORI-FLOW. To be able to meet the quality and security standards Bronkhorst is used to, we will accept only those Badger Meter valves which meet the Bronkhorst Quality Norm. This norm includes certain predefined specifications to enable our production department to adjust, optimize and test these valves if they were Bronkhorst valves. Main items on this Bronkhorst Quality Norm are: Limit amount of models: RC200, ¼, ½ and 1 types Special O-ring chambers in valve bodies for Swagelok RS adaptor types (no NPT) If no O-rings possible: adaptors welded to valve body Spindle seals: Kalrez compound 3035 (in stead of Teflon) for reduced emission For operation interface: ABB TEIP11 I/P-converter: input signal 4-20 ma / output signal 0,2-1 bara (or bara) If not possible: Samson positioner Please note that for proper functioning of the pump or valve the MFC needs to be adjusted electrically and also needs to be provided with the right parameter settings. This will be taken care of in our factory. For pump- or valve connections in the field after delivery, please contact your local sales representative page 9

10 1.1.5 Liquid dosing systems with pumps BRONKHORST CORI-TECH B.V. In Bronkhorst liquid mass dosing systems Liqui-Flow or CORI-FLOW instruments control liquid mass flow using a pump through a U/f converter. The pump is just used as an actuator to follow the controller to achieve the wanted mass flow (setpoint). It is not used as a positioner as it normally is, using the standard pump control software. Normally Bronkhorst will take care of all electrical and mechanical connections between the parts as mentioned above are realized, as well as an optimization of the PID-control and a test on water/ipa (when possible). The analog controller output signal, which normally would be used to drive a proportional valve, is limited to either 10 Vdc/15 Vdc and connected to the analog input signal of the pump drive. Each Liquid Dosing System consists of a flow sensor with controlling function, a pump and all inter-connecting material. A filter and check valve can be supplied on request. Furthermore, Bronkhorst will take care of electrical and mechanical connection, testing and optimization including the PID-integrated controller. In addition to the Bronkhorst Liquid Pump for small flow ranges, a complete series of pumps is available for those applications which require higher flow rates, higher pressures, wide control ranges or aggressive fluids. Further to operation in an analog mode, the system can also be used digitally with RS232 or with on-board interface to PROFIBUS-DP, DeviceNet, Modbus-RTU, or FLOW-BUS. See picture below for schematic setup. Please note that for proper functioning of the pump or valve the MFC needs to be adjusted electrically and also needs to be provided with the right parameter settings. This will be taken care of in our factory. For pump- or valve connections in the field after delivery, please contact your local sales representative. page

11 1.2 Sensor measuring principle Mini CORI-FLOW sensor Mini CORI-FLOW mass flow meters/controllers operate according to the Coriolis principle. The instrument can be used to simultaneously measure the mass flow, temperature and density. When a fluid flows through a vibrating tube, Coriolis forces are generated which bend or twist the tube. The extremely small tube displacements are detected by optimally positioned sensors and evaluated electronically. Since the measured phase shift of the sensor signals is proportional to the mass flow, the mini CORI-FLOW measures the mass flow directly. The measurement principle is independent of the density, temperature, viscosity, pressure, heat-capacity or conductivity. The tubes always vibrate at their natural frequency, which is a function not only of the tube geometry and the tube material properties but also the mass of the fluid in the vibrating tubes. 1.3 Valve principles Control valves are not designed to provide positive shut-off, although some models have excellent capabilities for this purpose. It is recommended to install a separate shut-off valve in the line if required. Also pressure surges, as may occur during system pressurisation must be avoided. The following models can be distinguished: Solenoid valve Flow control valve This is considered to be the standard (direct operated) control valve. In general it is a normally closed solenoid valve. The plunger is lifted by the force of the magnetic field of the coil. The orifice under the plunger is removable for optimising the orifice diameter. Also a normally opened solenoid valve is available Vary-P valve flow control valve pressure compensating valve For process conditions where up- and downstream pressure varies much, a special type of valve, VARY-P has been designed. This valve consists of two valves, a solenoid operated control valve and a fixed adjusted pressure compensation valve Pilot operated valve P1 pilot valve pressure compensating valve P2 For high flow rates the pilot operated valve has been designed. A solenoid driven control valve controls the pressure difference across a piston, which lifts the main plunger. flow control valve page 11

12 1.4 Software for physical properties of gases and liquids. Bronkhorst has access to the physical properties of over 600 fluids in a database called FLUIDAT. Application software, such as FLOW CALCULATIONS, enables the user to calculate properties, not only at 20 C / 1 atm but also at any temperature/pressure combination, both for gases and for liquids. Apply to your distributor for more details about this software. 1.5 (mini) Cori-Flow accuracy Zeroing of a (mini) Cori-Flow instrument is required each time process conditions have been changed. What is zero-stability? Due to mechanical construction of the sensor tubes each (mini) Cori-Flow sensor will have a very small offset signal, even when the mass flow is zero. This is called the zero-stability error and is specified for accuracy separately for all Coriolis instruments. Main reason for this is the fact that this error can be (temporarily) neutralized after performing a zero-action. Immediately after zeroing, zero-stability error is 0%. However, it is allowed to move between a certain band depending on the environment (process) and fluid conditions. In ideal situations, where actual process conditions do not change, this error will remain the same. See below for possible reasons of change of zero-stability. See also paragraph to learn how to zero. Zero-stability depends on the (mini) Cori-Flow model: Model DN (mm) Zero-stability Nominal flow M < 0.1 g/h 100 g/h M < 0.2 g/h 1 kg/h M < 6 g/h 10 kg/h M < 50 g/h 100 kg/h M53 1 < 10 g/h 5 kg/h M54 2 < 50 g/h 50 kg/h M55 4 < 100 g/h 500 kg/h Nominal flow: mass flow rate of liquid at a pressure drop of approx. 1 bar and based on reference conditions of water at approx. 20 C NOTE: In practice zero-stability turns out to be better than the values in the table, but for calculation we will take worst case values. Accuracy The accuracy of a (mini) Cori-Flow is either 0.2% reading for liquids or 0.5% reading for gases. This specification is based on mass flow (e.g. g/h, kg/h, etc.). If the instrument will be used on volume flow (e.g. l/h, ml/min, etc) this will introduce an extra inaccuracy, based on the density (measurement). Process conditions Each time process conditions have been changed significantly a (mini) Cori-Flow needs to be zeroed in order to get rid of the offset error due to zero-stability. At least the very first time an instrument is used a zero procedure will be required. The zero-stability error will mainly change when one or more of the following items change significantly: Temperature (of fluid or environment) Pressure Density of fluid Vibrations working on instrument via environment Pulsation of supply pressure working on instrument page

13 What changes are allowed? How many changes in quantity for certain process conditions are allowed without the need of a new zero procedure for the (mini) Cori-Flow depends on the influence this will have on the mass in the tubes. As soon as a fluid will be measured at its critical point, a small change in process conditions like temperature or pressure can already result in a rapid increase or decrease of density and/or dynamic viscosity. This will also influence the mass (flow) in the sensor tubes and therefore the zero stability. So please try to avoid phase changes or almost phase changes. E.g. CO2 and Ethylene have a large transition area ( no meat, no fish ). Experiences in practice turned out that measuring (and even controlling) in such an area can be highly accurate. So measuring in critical, or even supercritical area s, is good possible with (mini) Cori-Flow. Inaccuracies are to be expected when a phase change takes place. See also gas or liquid. Temperature changes of several C or pressure changes of several bar for e.g. Air when measuring at 20 C and 5 bara will not be a problem. This will not affect density or dynamic viscosity that much. However when measuring e.g. Ethylene at 10 C and 52 bara, a small increase of temperature or decrease of pressure will already result in large changes of density and even phase change. This last example might need a new zero procedure to get rid of offset errors due to zero stability. Error visualization +/- 0.05% repeatability + x % error (zero stability) 0 % -> time - x % error (zero stability) Temperature considerations Effects on accuracy: (Mini) Cori-Flow sensors do have an internal temperature measurement device for measuring fluid temperature and compensation on mechanical changes of the sensor due to temperature changes page 13

14 Error calculation: Total error = accuracy reading ± [(zero stab./flow)x100] [% reading] Example 1: error at 10 kg/h reading at M14 for a liquid (= ±0.2% of reading) zero stability error of M14 < 6 g/h; calculate with 6 g/h Total error = ±(0.2% + (6/10000 * 100))% = ±( )% = ±0.26 % (= ± 26 g/h) Example 2: error at 500 g/h reading at M13 for gases (= ±0.5% of reading) zero stability error of M13 < 0.2 g/h; calculate with 0.2 g/h Total error = ± (0.5% + (0.2/500 * 100))% = ±( )% = ±0.54 % (= ± 2.7 g/h) Example 3: Total error of M14 (at constant temperature) Total error M14 up to 30 kg/h 4% 3% 0.2 %RD + 6 g/h 2% Max. error [%RD] 1% 0% -1% -2% % -4% Flow [g/h] page

15 Gas and liquid (mini) Cori-Flows can be used for gases and liquids. In all instruments capable of density measurement (e.g. mini CORI-FLOW series) there will be an automatic adjustment for change in density. CORI-FLOW M50-series however, cannot measure density. For those instruments it is advisable to calibrate them on air for gases and on water for liquids. Multi-range instrument Thanks to extremely high linearity of the sensor, (mini) Cori-Flow instruments can be easily re-ranged to a different full scale range (100% point). The analog output and the digital measured flow value will be scaled to this FS 100% point. E.g. An M13 can be used for a full scale between 50 g/h and 2000 g/h. Switching between these ranges can be realized using fieldbus, E-7000, Bright module or RS232 interface. There is free tooling software (FlowPlot) available for this purpose. Mini Cori-Flow instruments will get a calibration certificate for all possible FS ranges. The actual FS of the instrument is set to a value wanted by the customer and can be found on the gray sticker on the instrument. Summary In general: a (mini) Cori-Flow instrument is independent of physical properties. Performing an auto-zero on actual conditions (with zero flow) before use will get rid of offsets in the sensor. When these properties, like temperature, pressure, density and dynamic viscosity do not affect the mass in the tube or the mechanical sensor construction to much, error due to zero-stability will be small. Environment conditions are important to the mechanical behaviour of the sensor: Vibrations (of sensor, rack, pipes etc.) with frequencies or harmonics close to the sensor s natural frequency could result in errors in the measurement. Sensor oscillation frequencies vary from Hz, depending on the model. Pulsation of supply pressure may have negative influence on accuracy. Avoiding this is the best. Filtering is an option for improvement. Turbulences in flow may add extra noise to the measured value. Especially with high flow of gases straight pipes with lengths of cm. at least are advisable for realizing a more undisturbed flow. For other applications (e.g. liquids) inlets of about 10x inner diameter of tube are sufficient. Smooth reducing from wide to small tubes is advisable. See below: Optimal angle is approx. 7 Gas bubbles entrapped in liquids (and/or locked-up in sensor tube) give disturbances to flow measurement, especially in the lower flow ranges. Try to avoid this and purge with high flow to remove them. Fluid drops in gas flow (and/or locked-up in sensor tube) give disturbances to flow measurement, especially in lower flow ranges. Try to avoid this and purge with high flow to remove them page 15

16 2 INSTALLATION BRONKHORST CORI-TECH B.V. 2.1 Receipt of equipment Check the outside packing box for damage incurred during shipment. Should the packing box be damaged, then the local carrier must be notified at once regarding his liability, if so required. At the same time a report should be submitted to: BRONKHORST CORI-TECH B.V. RUURLO HOLLAND If applicable, otherwise contact your distributor. Remove the envelope containing the packing list; carefully remove the equipment from the packing box. Do not discard spare or replacement parts with the packing material and inspect the contents for damaged or missing parts. 2.2 Return shipment When returning material, always describe the problem and if possible the work to be done, in a covering letter. It is absolutely required to notify the factory if toxic or dangerous fluids have been metered with the instrument! This to enable the factory to take sufficient precautionary measures to safe-guard the staff in their repair department. Take proper care of packaging. If possible use the original packing box. Seal instrument in plastic Contaminated instruments must be dispatched with a completely filled in 'declaration on contamination form'. Contaminated instruments without this declaration will not be accepted. Note: If the instruments have been used with toxic or dangerous fluids the customer should pre-clean the instrument. Important: Clearly note, on top of the package, the customer clearance number of Bronkhorst Cori-Tech B.V., namely: NL B01 If applicable, otherwise contact your distributor for local arrangements. 2.3 Service If the equipment is not properly serviced, serious personal injury and/or damage to the equipment could be the result. It is therefore important that servicing is performed by trained and qualified service personnel. Bronkhorst Cori-Tech B.V. has a trained staff of servicemen available. 2.4 Mounting For the M12..M14 proper stable mounting is strongly advised on a rigid, solid base for optimal accuracy. For optimal isolation for vibrations in the area, rubber dampeners can be used. In the picture left an example of what Bronkhorst can provide for these purposes. This is not needed for the M15 because of a different sensor construction (box in box principle). Please see Short form instruction manual mini CORI-FLOW, document nr for more detailed information about mounting. page

17 2.5 Notes for temperature considerations The mini CORI-FLOW has to be installed in such a way that levels of different temperature within the mini CORI-FLOW are avoided. Avoid multiple heating and cooling of the instrument. Temperature shocks have to be avoided in any case. (max. 1 C/sec) After using the mini CORI-FLOW the first time at low temperature tighten the connector screws again in order to prevent any leakage! Please note: if you do not tighten the screws, the leaking connector / fitting can cause damage! After the first shrinking and tightening of the screws, no further precaution is necessary. Note that the maximum temperature in the housing of the mini CORI-FLOW is allowed to be up to 70 ºC max. Also note that a mini CORI-FLOW will have an amount of self-heating due to the power dissipation on the electronics (DSP). This self-heating can be up to approx. 15 ºC. It will be at maximum if there is no flow (less cooling). In practice, there will be a balance between fluid temperature, self heating, cooling effects and ambient temperature at the instrument. If the fluid is really hot, it would help if the instrument is in a cool environment. It will also depend on how well the installation where the instrument has been mounted in/on is capable of cooling. Anyway, one must take care that the instrument in the housing will not exceed the 70 C, otherwise the electronics will be damaged. To check this, the internal temperature sensor can be used. Via FLOW-DDE/E-7000 or Bright it can be read out. (FlowDDE par. 142). Please make sure the temperature value readout here (=actual temperature in housing) will not exceed 70 C. Down below some facts about maximum Tambient and Tfluid: Max. temperature in housing is 70ºC,but: Operating temperature conditions (continuous): Tfluid + Tambient < 110ºC With: Tfluid < 100ºC Tambient < 55ºC For cleaning purpose, instrument without power (continuous) Tfluid + Tambient < 130ºC With: Tfluid < 130ºC T ambient < 80ºC In all situations: Tfluid > 0 ºC Tambient > 0 ºC Storage temperature (dry tube) [ ] ºC page 17

18 2.6 Fluid/gas connections Bronkhorst Cori-Tech B.V. mini CORI-FLOW meters/controllers are equipped with compression or face-sealfittings. For leak tight installation of compression type fittings make sure that the tube is inserted to the shoulder in the fitting body and that no dirt or dust is present on tube, ferrules or fittings. Tighten the nut fingertight; while holding the instrument and then tighten the nut 1 turn. If applicable follow the guidelines of the supplier of the fittings. Special types of fittings are available on request. * Note: Always check your system for leaks, before applying fluid/gas pressure. Especially if toxic, explosive or other dangerous fluids are used. 2.7 Piping BE SURE THAT PIPING IS ABSOLUTELY CLEAN! DO NOT install small diameter piping on high flow rates, because the inlet jet-flow will affect the accuracy. DO NOT mount abrupt angles direct on in- and outlet, especially not with high flow rates. We recommend at least 20 pipe diameters distance between the angle and the instrument. Special care should be taken in regard to reducers placed just in front of the mini CORI-FLOW. High pressure drop and flow disturbance can occur which can influence the mini CORI-FLOW. 2.8 Electrical connections Bronkhorst Cori-Tech B.V. recommends using their standard cables. These cables have the right connectors and if loose ends are used, these will be marked to prevent wrong connection. 2.9 Pressure testing Each CORI-FLOW is pressure tested to at least 1.5 times the working pressure of the process conditions stipulated by the customer, with a minimum of 8 bara. The tested pressure is stated on the flow meter/controller with a RED COLOURED sticker. Check test pressure before installing in the line. If the sticker is not available or the test pressure is incorrect, the instrument should not be mounted in the process line and be returned to the factory. Each instrument is helium leak tested to at least mbar l/s Helium outboard Supply pressure Do not apply pressure until electrical connections are made. When applying pressure to the system, take care to avoid pressure shocks in the system and increase pressure gradually, especially on high pressure units incorporating a piston operated control valve. Make sure in case of a controller that the used valve can withstand the system pressure. Give special attention to the maximum delta pressure of the valve. page

19 2.11 System purging If explosive gases are to be used, purge the process with inert dry gas like Nitrogen, Argon etc. for at least 30 minutes at a high enough flow. In systems with corrosive or reactive fluids, purging with an inert gas is absolutely necessary, before taking in use. Preventing chemical reactions inside the tubes or instrument as this will tend to clog up or corrode the system. Complete purging is also required to remove such fluids from the system before exposing the system to air. It is preferred not to expose the system to air, when working with these corrosive fluids Seals Bronkhorst Cori-Tech B.V. has gathered a material compatibility chart from a number of sources believed to be reliable. However, it is a general guide only. Operating conditions may substantially change the accuracy of this guide. Therefore there is no liability for damages occurring from the use of this guide. The customer s application will demand its own specific design or test evaluation for optimum reliability. So check if the seals like O-rings and plunger are correct for the process Equipment storage The equipment should be stored in its original packing in a cupboard warehouse or similar. Care should be taken not to subject the equipment to excessive temperatures, humidity, vibrations or shocks page 19

20 2.14 Electromagnetic compatibility BRONKHORST CORI-TECH B.V. Conditions for compliance with EMC requirements All instruments described in this manual carry the CE-mark. Therefore they have to comply with the EMC requirements, as they are valid for these instruments. However compliance with the EMC requirements is not possible without the use of proper cables and connector/gland assemblies. For good results Bronkhorst Cori-Tech B.V. can provide standard cables. Otherwise follow the guidelines as stated below. 1. Connector mini CORI-FLOW 8 DIN CONNECTOR AMPHENOL C091 31D METAL RING TRANSPARANT TUBING FOLD THE SHIELD OF THE CABLE BACK OVER THE CABLE.(THE SHIELD MUST BE AROUND THE CABLE) SHIELD OF THE CABLE SHOULD BE CONNECTED TO THE CONNECTORHOUSING O-RING solder-side Amphenol 8-pin DIN connector female CABLE LIYCY 8x0.25mm 2 SHRINK SOLDERCONTACTS WITH SHRINKTUBING BRE 160 BLACK OR EQ. 20 mm 8 DIN CONNECTOR BINDER SERIE BLACK TUBING DETAIL SHIELD OF THE CABLE SHOULD BE CONNECTED TO THE CONNECTORHOUSING FOLD THE SHIELD OF THE CABLE BACK OVER THE CABLE.(THE SHIELD MUST BE AROUND THE CABLE) O-RING DETAIL solder-side Binder 8-pin DIN connector female SHRINK SOLDERCONTACTS WITH SHRINKTUBING BRE 160 BLACK OR EQ mm CABLE LIYCY 8x0.25mm 2 page

21 2. Cable gland assembly shield 15 mm 35 mm Fold the shield of the cable back over the cable (shield must be around the cable). shielded cable e.g. LAPP LiYCY shield metal cable gland e.g. HUMMEL HSK-M-EMV Mount the metal PG cable gland as shown in the drawing above. Note: When connecting the system to other devices (e.g. to PLC), be sure that the integrity of the shielding is not affected. Do not use unshielded wire terminals. 1. For FLOW-BUS S(F)TP data (patch) cable connection to M12 connectors follow the instructions of the supplier. It is important to use shielded twisted pair cables and shielded RJ45 modular jack connectors. 2. For PROFIBUS-DP, Modbus or DeviceNet data cable connections follow the instructions of the cable suppliers for the specific field-bus system Electro static discharge This instrument contains electronic components that are susceptible to damage by static electric discharges. Proper handling procedures must be taken during installation, removing and connecting the electronics page 21

22 3 OPERATION BRONKHORST CORI-TECH B.V. 3.1 General The Bronkhorst Cori-Tech B.V. instruments are designed in such a way that they will meet user process requirements in the best possible way. The mini CORI-FLOW meters/controllers can be powered from +15 Vdc to +24 Vdc. When providing your own power supply be sure that voltage and current rating are according to the specifications of the instrument(s) and furthermore that the source is capable of delivering enough power to the instrument(s). Cable wire diameters should be sufficient to carry the supply current and voltage losses must be kept as low as possible. When in doubt: consult factory. Mini CORI-FLOW instruments can be operated by means of: 1. Analog interface (0...5Vdc/0...10Vdc/0...20mA/4...20mA) 2. RS232 interface (connected to COM-port by means of special cable on Baud) 3. FLOW-BUS 4. PROFIBUS-DP 5. DeviceNet 6. Modbus 7. other fieldbus interfaces on request Option 1 and 2 are always present on multibus instruments. An interface to any available fieldbus is optional. Operation via analog interface, RS232 interface and an optional fieldbus can be performed at the same time. A special parameter called control mode indicates to which setpoint the controller should respond: analog or digital (via fieldbus or RS232). The RS232 interface behaves like a FLOW-BUS interface. When using more interfaces at the same time, reading and operation can be done simultaneously without problems. When changing a parameter value, the last value send by an interface will be valid. Also the push-button switch and the LED s on the left side of the instrument can be used for manual operation of some options. The green LED will indicate in what mode the instrument is active. The red LED will indicate error/warning situations. 3.2 Power and warm-up Before switching on power, check if all connections have been made according to the hook-up diagram which belongs to the instrument. Check fluid connections and make sure there is no leakage. If needed, purge the system with a proper fluid. For a gas instrument only purging with gases is allowed. Liquid instruments may be purged with either a gas or a liquid, whatever is needed for the purpose. Turn on power and allow at least 30 minutes to warm up and stabilise. In cases where no electronics are involved (valves only) warming up is not needed. During warm-up period, fluid pressure may either be on or off. 3.3 Start-up Turn on fluid supply gently. Avoid pressure shocks, and bring the instrument gradually up to the level of the actual operating conditions. Also switch off fluid supply gently when shutting down. page

23 3.4 Zeroing What is zero-stability? Due to mechanical construction of the sensor tubes each Coriolis sensor will have a very small offset signal, even when the mass flow is zero. This is called the zero-stability error and is specified for accuracy separately for all Coriolis instruments. Main reason for this is the fact that this error can be neutralized after performing a zero-action. Immediately after zeroing, zero-stability error is 0%. However it is allowed to move between a certain band depending on the environment and fluid conditions. In ideal situations where actual process conditions do not change, this error will remain the same. Each time process conditions have been changed significantly a mini CORI-FLOW needs to be zeroed in order to get rid of the offset error due to zero-stability. At least the very first time an instrument is used a zero procedure will be required. The zero-stability error might change when one or more of the following items change significantly: Mainly: Temperature (of fluid and environment) Mounting position of instrument Less important: Dynamic viscosity of fluid Vibrations working on instrument via environment Pulsation of supply pressure working on instrument Pressure Density of fluid Procedure for zeroing (See also Short form instruction manual mini CORI-FLOW, document nr ) Warm-up instrument for at least 30 minutes. Purge as long as needed with fluid to make sure there is no gas in the liquid or no condensate in the gas Fill instrument with fluid under process conditions. Close all valves at output to establish zero flow. Closing valves at input will not be critical (under circumstances even better to let them open) but extra shut-off valves at output should be closed, as well as control valve of instrument e.g. by means of setpoint = 0% or control mode = close valve. To start the zero procedure: Press push-button switch (#) on the side of the instrument and hold it (LED s will respond) until only the green LED is burning and then release the button. This command is also possible via any available fieldbus- or RS232 interface. The zeroing procedure will start at that moment and can be monitored by the LED s. The green LED will blink until the procedure is ready. This will take about 30 seconds. When it is ready it will burn green continuously again Zero-procedure information If the instrument has problems finding a proper and stable zero, it will repeat the auto-zero step a few times (max. 4 times). Each time no proper zero can be achieved, the instrument will give a short notice signalling its LED s after the procedure. The red and green LED will blink turn-by-turn for a few seconds to indicate that the auto-zero wasn t able to find a zero (because of too much noise in the signal). This is mostly the case when the instrument is placed in a vibrating environment. When ready zeroing after trying several (max. 4) times, the final result for the zero value will be a moving average value of all attempts. The instrument will save this zero value into its non-volatile memory and will keep this value until a next zero-procedure will be performed. This value (Sensor Input Zero Scale Adjustment) can be accessed (read/written), via parameter 218 in the parameter table of FlowDDE (note: Depending on firmware of instrument). The mini CORI-FLOW will accept a proper zero only if the measured signal is within a limited noise band. Best way to achieve this is to avoid external noise influences. However, when this is not possible, filter settings of the mini CORI-FLOW can be changed to improve noise immunity. Important: Always make sure that there is absolutely no flow when the instrument is performing the (auto-)zero procedure and there are no vibrations or pulsating inlet pressures page 23

24 3.4.4 Alternatives for starting zero procedure Through FLOW-BUS, using an E-7000 readout/control module. Through FLOW-BUS, via a RS232/FLOW-BUS converter using software on a PC or PLC. Through RS232, using software on a PC or PLC Through RS232, using a Bright compact local readout/control module Through other fieldbus system (PROFIBUS-DP/DeviceNet/ModBus) Zeroing with the Micro-switch Before using the instrument zeroing is required. Set process conditions After warm-up, pressure up and fill system including the mini CORI-FLOW according to the process conditions. Stop flow Make sure there is no flow through the instrument by closing the shut-off valves before and after the instrument. Press and hold, until GREEN LED is on, than release button With no flow, use the push-button switch (#) on the left side of the instrument to start the zero adjustment procedure. Press the push-button (#) and hold it, after a short time the red LED will go ON and OFF then the green LED will go ON. At that moment release the push-button (#). Zeroing The zeroing procedure will start at that moment and the green LED will blink fast. The zeroing procedure waits for a stable signal and saves the zero. If the signal is not stable, zeroing will take long and the nearest point to zero is accepted. The procedure will take approx. 25 sec. Make sure that there is no flow through the instrument when performing the zeroing procedure. Ready When indication is showing 0% signal and the green indication LED is continuously on, then zero has been performed well Zeroing through the digital communication It is also possible to start the zero adjustment procedure through the FLOW-BUS, using an E-7000 readout/control unit or a software program on a PC, connected to a FLOW-BUS interface module. The following parameters must be used for zeroing an instrument: Initreset [unsigned char, RW, , DDEpar. = 7, Proces/par. = 0/10] Cntrlmode [unsigned char, RW, , DDEpar. = 12, Proces/par. = 1/4] CalMode [unsigned char, RW, , DDEpar. = 58, Proces/par. = 115/1] Set process conditions Warm-up, pressure up the system and fill the instrument according to the process conditions. Stop flow Make sure there is no flow through the instrument by closing the shut-off valves before and after the instrument. Send parameters Send the following values to the parameters in this sequence. Initreset 64 Cntrlmode 9 Calmode 255 Calmode 0 Calmode 9 Zeroing The zeroing procedure will start at that moment and the green LED will blink fast. The zeroing procedure waits for a stable signal and saves the zero. If the signal is not stable zeroing, will take long and the nearest point to zero is accepted. The procedure will take approx. 25 sec. Make sure there is no flow through the instrument when performing the zeroing procedure. Ready When indication is showing 0% signal and the green indication LED is burning continuously again, then zeroing has been performed well. Also parameter control mode goes back to its original value. As last send 0 to parameter initreset. page

25 3.5 Operating conditions Each instrument has been adjusted for customer process conditions, if possible. Controllers or valves may not operate correctly, if process conditions vary too much, because of the restriction of the orifice in the valve. Please change supply- or backpressure to improve control behaviour. If this does not help, contact your local sales representative to assist you. 3.6 Manual operation By means of manual operation of the push-button switch (#) some important actions for the instrument can be selected/started. These options are available in both analog and BUS/digital operation modes. (See also manual operation in document number ) These functions are: - Reset (instrument firmware-program reset) - Reset in case of an alarm - Zeroing - Restore factory settings (in case of unintentionally change of the settings) for FLOW-BUS only: - Automatic installation to FLOW-BUS (installs instrument to free address) - Remote installation to FLOW-BUS (instruments will be installed by E-7000 or PC-software) 3.7 Analog operation Digital instruments can be operated with analog signals through the 8-pin circular connector. The instruments are compatible in use with analog instruments on this point. Analog operated instruments, can be hooked up using an 8-wire shielded cable, connected according to the Bronkhorst Cori-Tech standard. Each electronic PC-board is set for one of the following output (and corresponding input) signals: Signal output (sensor) input (setpoint) code signal signal A 0 5 Vdc 0 5 Vdc B 0 10 Vdc 0 10 Vdc F 0 20 ma (sourcing) 0 20 ma (sinking) G 4 20 ma (sourcing) 4 20 ma (sinking) Current output signals Sourcing instrument output 0V common I + ma - For meters only the output signal is available. At analog operation the following parameters are available: - measured value - setpoint (controllers only) - valve voltage (controllers only) page 25

26 Note: When operating the instrument through the analog interface it is possible to connect the instrument to any supported fieldbus system (or RS232-interface with special cable) for reading/changing parameters (e.g. controller response or other fluid selection). For FLOW-BUS versions of the instruments a readout/control module for digital instruments can be temporarily connected to the M12 fieldbus connector. 3.8 BUS / digital operation Operation via fieldbus reduces the amount of cables to build a system of several instruments and offers more parameter values to be monitored/changed by the user. See instruction manual: operating digital mass flow / pressure instruments for more details (document nr ). Operation by means of a fieldbus adds a lot of extra features (compared to analog operation) to the instruments. Such as: - adjustable filter settings to smoothen or speed-up the output signal - setpoint slope (ramp function on setpoint for smooth control) - adjustment of controller output (response time) for valve or pump control (PID-settings) - direct reading at readout/control module or host computer - testing and self diagnosis - response alarm (setpoint-measure too high for too long time) - several control/setpoint modes (e.g. purge/close valve) - master/slave modes for ratio control (FLOW-BUS only) - identification (serial number, model number, device type, user tag) - adjustable minimal and maximal alarm limits - (batch) counter - adjustable response time for controller when opening from zero - adjustable response time for normal control - adjustable response time for stable control ( setpoint-measure < 2%) Special software like FlowDDE, FlowPlot and FlowView can be used to control these settings. For operation of digital instruments by means of a specific fieldbus system or RS232, see following documents (available as PDF-file): for FLOW-BUS document number: for PROFIBUS-DP document number: for DeviceNet document number: for RS232 document number for Modbus document number page

27 3.9 RS232 communication cable T-part BRONKHORST CORI-TECH B.V. Fieldbus Power,Analog input, Analog output RS232 Note: Special RS232 cable has partnr and consists of a T-part with 1 male and 1 female 8-pin DIN connector on one instrument-side and a normal female sub-d 9 connector on the side of the computer. By means of this cable it is possible to offer RS232 communication and still be able to connect power-supply and analog interface through the (analog) 8-pin DIN connector. RS232 communication is only possible with a baudrate of 38.4 KBaud and can be used for either: Uploading new firmware by means of a special program (for trained Bronkhorst-service personnel only) Servicing your instrument using Bronkhorst-service programs (for trained Bronkhorst-service personnel only) Operating your instrument using FLOWDDE, FLOWB32.DLL or RS232-ASCII protocol (end user) page 27

28 4 MAINTENANCE 4.1 General BRONKHORST CORI-TECH B.V. No routine maintenance is required to be performed on the meters or controllers. In case of severe contamination it may be required to clean the valve orifice separately. 4.2 mini CORI-FLOW sensor The mini CORI-FLOW sensor is constructed in such a way that there is very little dead volume. The sensor is maintenance free. 4.3 Controllers All sensor types can be combined with a control valve to be operated together as a control loop. Controller systems are either available as separate units; a sensor and a control valve, or as an integrated unit. If applicable maintenance procedures are described under control valves 4.4 Control valves Control valves cannot be used for shut-off and/or on-off applications. Pressure surges, as may occur during system pressurisation or deflation must be avoided Solenoid valves These are considered to be the directly operated control and pilot valves. They can be disassembled in the field by the user for cleaning and servicing. The parts can be cleaned with a cleaning liquid, or in an ultrasonic bath. To disassemble the valve proceed as follows: a) disconnect the instrument connector (not necessary with separate valve) b) remove the hex nut on top of the valve assembly c) lift the cover (coil) assembly d) unscrew the flange e) lift valve assembly carefully from the base f) unscrew set screw for the orifice and subsequently loosen the orifice and the orifice holder g) remove the plunger assembly Clean parts and carefully re-assemble in reverse order. It is recommended to replace the O-rings prior to reassembly. After having re-assembled the control valve, it is recommended to check the control characteristics of the valve. This can best be done by using a separate variable 15 Vdc power supply source. Proceed as follows: - disconnect the valve leads and connect to supply source - apply gas pressure as per working conditions - apply power by gradually increasing voltage - the valve should open at 7 Vdc 3 Vdc - the fully opened position is reached at approx. 9 Vdc 1.5 Vdc. In case the valve does not operate within the voltage levels stated, then it must be disassembled, and the orifice must be adjusted to the proper position. Re-assemble valve and repeat procedure if required Vary-P valve The vary-p valve is designed to cope with extremely varying process conditions on either upstream or downstream side of the valve or a combination of these. p can vary over a wide range. The basic control valve is a direct operated solenoid control valve. The design has been patented. For orifice selection and maintenance other than the pilot valve consult the factory. page

29 4.4.3 Pilot operated valve This control valve is an indirect control valve, consisting of a spring loaded membrane/orifice system which is positioned by a solenoid operated direct control (pilot valve). The two devices are integrated in one block. Basically follow the same procedures for dis-assembly as stipulated under Solenoid valves For cleaning purposes it may be required to dis-assemble further, i.e. also remove the membrane assembly. For pilot operated valves the maximum pressure drop is limited to 20 bard. If the pressure drop during start-up is higher, it is preferred to install a bypass valve. During start-up this valve should be opened. Also the minimum pressure drop is limited. For exact figures consult factory or proceed according to the technical data and/or additional instructions given by the sales office or department. Note: When pressure testing a system incorporating a pilot operated control valve, a special procedure must be followed in order to prevent damage to the valve. In such cases it is necessary to contact the factory prior to do this. 4.5 K v -value calculation This calculation method can be used to determine the K v -value of the main orifice of a control valve For gases Determine desired p across valve. p must be at least 20% of supply pressure, or in closed loop systems, of total pressure difference in the loop. If p is 20-50% of supply pressure, use formula: K v m n T 514 n p p 2 under critical If P is % of supply pressure, use formula: K v m 257 p1 n T n over critical Units: m = flow [kg/h] p 1 = supply pressure [bara] p 2 = downstream pressure [bara] p = pressure difference (p 1 - p 2 ) [bara] T = temperature [K] n = density [kg/m 3 n ] The orifice diameter can be determined by: d= 7.6 K v [mm] page 29

30 4.5.2 For Liquids Determine desired p across valve. p must be at least 50% of supply pressure Kv-value calculation K v m p 1000 Units: flow - m (kg/h) 3 density - (kg / m ) at 20 C and 1 atm. delta p - p(bard) The orifice bore diameter can be determined by: d 7.6 Kv [mm] For C2 type of valves the diameter of the orifice can be calculated as shown above or looked up in the graph below. customer vh 2O = vcustomer H 2 O in which: v = volume flow = density d = 1.0 mm d = 0.7 mm 10 4 d = 0.5 mm 10 4 d = 0.37 mm d = 0.3 mm d = 0.2 mm 10 3 d = 0.14 mm 10 3 d = 0.1 mm O v H O (ml/h) P m a x P (b a r) If liquids have viscosity s >15 mpa.s (water = 1 mpa.s), the flat orifice and plunger type control mechanism cannot be used. For measuring systems only check maximum possible viscosity with factory. page

31 4.6 Calibration procedure All instruments are factory calibrated on all possible ranges, independent of customer conditions. Calibration will be performed with water under normal temperature and atmospheric conditions (20 C and 1 bara). After calibration the instruments will be dried thoroughly. Instruments will be calibrated using water on 6 points over the full flow range where the instrument can be used for. Because Coriolis instruments measure mass flow, they will have the same accuracy for all fluids and therefore calibrations on actual fluids will not be necessary. Also density will be calibrated and calibration checks on air will be performed. For the flow calibration, the instrument will be set to the maximum full scale value and seven points (including zero) will be compared with a reference. All points will be shown in a graph to illustrate that they are within limits of total accuracy (±0.2% ±Zero Stability). After this calibration, the actual capacity (full scale) value will be set to the wanted flow value ordered by the enduser. This value can be easily changed on site by the enduser using Bronkhorst tooling software (FlowDDE and FlowPlot) which can be downloaded from the website: Thus re-ranging the instrument will be possible between a minimum and a maximum capacity. Over this complete range the instrument calibration certificate will be valid. Analog outputs (A: 0 5Vdc /B: 0 10Vdc /F: 0 20mA /G: 4 20mA) for flow and analog inputs for giving setpoints to controllers, will be adjusted as ordered. These adjustments include an extra uncertainty of < ±0.1% at each input as well as at each output. The analog output and -input maximum values are equal to the actual capacity (full scale) value of the instrument and will be linear to the flow. If the instrument will be re-ranged: actual capacity will be set to another value, this analog value will get another meaning. The original, factory set, actual capacity (full scale) value and type of analog signal will be displayed on the grey sticker on the instrument. This will be the value what the instrument had been ordered for. G: 4 20mA analog input and output Capacity (FS) = 150 g/h Mix Example: M13 instrument has a maximum flow of max g/h. It will be calibrated up to 2000 g/h on 7 points, including zero. Enduser wants to use it with 4 20 ma and orders the instrument for 150 g/h. When the instrument leaves the factory 20mA will correspond with 150 g/h. After re-ranging it to a full scale of 500 g/h, 20mA will correspond with 500 g/h Mix. After re-ranging it to a full scale of 2000 g/h, 20mA wil correspond with 2000 g/h. Note: The fluidname Mix is just indicative for actual use. However, the meter will measure all fluids with same accuracy as long as the instrument is capable of handling the fluid (pressure drop, corrosion resistance, suitability of valve or pump etc.) page 31

32 4.7 Instrument re-ranging Re-ranging can easily be performed by changing the capacity of the instrument. This can be performed by using FlowPlot, E-7000 or Bright readout/control module, RS232 digital communication or any available fieldbus communication interface supporting parameter 21: capacity. Capacity can be set between minimum capacity and maximum capacity. The actual values depend on the type of instrument. FlowPlot can be downloaded at: Example of changing flow range using FlowPlot: Enter max flow range here (capacity) or move the slider. 4.8 Instrument filter settings Changing filter settings can be done using FlowPlot. FlowPlot can be downloaded at: Output filter: Dynamic display factor and Static display factor are filter settings for readout only (at analog output and digital output). Output signal filtering at stable situation and at a flow-step can be set separately. Sensor filter: Exponential smoothing factor is the most important filter parameter to influence the stability of the meter and will also influence the controller behaviour, where it will be provided as input for the controller. Adaptive smoothing factor does not have functionality for a mini CORI-FLOW. For a mini CORI-FLOW it will temporarily switch off the filter during a flow-step to enable fast controller behaviour together with strong filtering. For all filter settings: A value can be entered between 0 and 1, where values close to 0 will filter strongly and slow down the output. A value close to 1 will speed-up the output and will introduce more noise. At value = 0, the filter has been switched off. No signal is put-through: no signal changing. At value = 1, the output is equal to the input: no filtering at all. page

Quick Installation Guide Doc nr.: C Date:

Quick Installation Guide Doc nr.: C Date: Quick Installation Guide Doc nr.: 9.17.093C Date: 13-05-2016 SCOPE OF THIS GUIDE mini CORI-FLOW instruments are highly accurate instruments for measuring and controlling the mass flow rate of liquids and/or

More information

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties Quick Installation Guide Doc nr.: 9.17.052H Date: 10-12-2015 SCOPE OF THIS GUIDE mini CORI-FLOW instruments are highly accurate instruments for measuring and controlling the mass flow rate of liquids and/or

More information

General instructions digital Mass Flow instrument CORI-FLOW

General instructions digital Mass Flow instrument CORI-FLOW Instruction manual General instructions digital Mass Flow instrument CORI-FLOW Doc. no.: 9.17.031J Date: 14-12-2015 ATTENTION Please read this instruction manual carefully before installing and operating

More information

Instruction manual. General instructions digital Mass Flow instrument LIQUI-FLOW L30. Doc. no.: E Date:

Instruction manual. General instructions digital Mass Flow instrument LIQUI-FLOW L30. Doc. no.: E Date: Instruction manual General instructions digital Mass Flow instrument LIQUI-FLOW L30 Doc. no.: 9.17.044E Date: 18-02-2014 ATTENTION Please read this instruction manual carefully before installing and operating

More information

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers MASS-STREAM TM Instruction Manual D-6200 Analog Mass Flow Meters / Controllers Doc. No.: 9.17.112A Date: 17-03-2017 ATTENTION Before installing and operating the instrument it is strongly recommended that

More information

Instruction manual. CEM controlled evaporator and mixer. Doc. no.: H Date:

Instruction manual. CEM controlled evaporator and mixer. Doc. no.: H Date: Instruction manual CEM controlled evaporator and mixer Doc. no.: 9.17.010H Date: 22-11-2011 ATTENTION Before installing and operating the instrument it is recommended that this instruction be read. Not

More information

Precision Mass Flow Meters / Controllers for Liquids and Gases

Precision Mass Flow Meters / Controllers for Liquids and Gases CORI-FLOW TM Precision Mass Flow Meters / Controllers for Liquids and Gases Introduction Bronkhorst Cori-Tech B.V. manufactures precise, compact Mass Flow Meters and Controllers for gases and liquids,

More information

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES SENSORS FOR MASS FLOW AND PRESSURE CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES INTRODUCTION Bronkhorst High-Tech BV is the worldwide pioneer in the field of low flow liquid metering

More information

Instruction manual. General instructions digital Mass Flow / Pressure instruments laboratory style / IN-FLOW. Doc. no.: Y Date:

Instruction manual. General instructions digital Mass Flow / Pressure instruments laboratory style / IN-FLOW. Doc. no.: Y Date: Instruction manual General instructions digital Mass Flow / Pressure instruments laboratory style / IN-FLOW Doc. no.: 9.17.022Y Date: 17-01-2018 ATTENTION Please read this instruction manual carefully

More information

Instruction manual. MASS-VIEW series. Doc. nr.: F Date:

Instruction manual. MASS-VIEW series. Doc. nr.: F Date: Instruction manual MASS-VIEW series Doc. nr.: 9.17.051F Date: 22-12-2016 ATTENTION Please read this instruction manual carefully before installing and operating the instrument. Not following the guidelines

More information

Instruction Manual. Doc. no.: D Date:

Instruction Manual. Doc. no.: D Date: Instruction Manual CORI-FILL Setting up (mini) CORI-FLOW instruments for filling applications Doc. no.: 9.17.075D Date: 10-01-2018 ATTENTION Please read this Instruction Manual carefully before installing

More information

Model 601CV. Mass Flow Controller. Product Features:

Model 601CV. Mass Flow Controller. Product Features: Model 601CV Mass Flow Controller Porter s Model 601CV Series II Mass Flow Controller (MFCs) is designed for precise control of virtually all conventional process gases. The MFC consists of a thermal mass

More information

Instruction Manual. Doc. no.: A Date:

Instruction Manual. Doc. no.: A Date: Instruction Manual Controlled Evaporator and Mixer (CEM) Doc. no.: 9.17.126A Date: 02-10-2018 ATTENTION Please read this Instruction Manual carefully before installing and operating the instrument. Not

More information

Liquids and Gases Gas & Liquid

Liquids and Gases Gas & Liquid mini CORI-FLOWTM Compact Coriolis Mass Flow Meters & Controllers for Liquids and Gases Gas & Liquid Contents Facts about Coriolis Flow Measurement and Control 3 Mass Flow Meters 4 Mass Flow Controllers

More information

ACV-10 Automatic Control Valve

ACV-10 Automatic Control Valve ACV-10 Automatic Control Valve Installation, Operation & Maintenance General: The Archer Instruments ACV-10 is a precision automatic feed rate control valve for use in vacuum systems feeding Chlorine,

More information

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM M+W Instruments Your partner Key Facts M+W Instruments was founded in 1988 and has always specialised in thermal mass flow meters

More information

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司 X-Flow Mass Flow Controller 2 Highlights Parker Hannifin Precision Fluidics Division is excited to introduce X-Flow, a new easy to use general purpose mass flow controller for your instrument, lab, or

More information

Operating Instructions for Direct Flow Mass Flow Meter for gases. Model: DMW

Operating Instructions for Direct Flow Mass Flow Meter for gases. Model: DMW Operating Instructions for Direct Flow Mass Flow Meter for gases Model: DMW 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 5.1.

More information

IN-FLOW CTA Industrial Mass Flow Meters and Controllers for Gases

IN-FLOW CTA Industrial Mass Flow Meters and Controllers for Gases IN-FLOW CTA Industrial Mass Flow Meters and Controllers for Gases > Introduction Bronkhorst High-Tech B.V., the European market leader in thermal Mass Flow Meters/Controllers and Electronic Pressure Controllers,

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication

More information

Digital Mass Flow Meters and Controllers for Gases

Digital Mass Flow Meters and Controllers for Gases Digital Mass Flow Meters and Controllers for Gases A Bronkhorst company. M+W Instruments. Your specialists for inline measurement WORTH KNOWING M+W Instruments was founded in 1988 and has always specialised

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability

More information

PORTER. USER S MANUAL for Models LM, HM, LC and HC. FM-653 Rev. B 8/02

PORTER. USER S MANUAL for Models LM, HM, LC and HC. FM-653 Rev. B 8/02 PORTER M A S S F L O W M E T E R S A N D F L O W C O N T R O L L E R S F O R L I Q U I D S USER S MANUAL for Models LM, HM, LC and HC FM-653 Rev. B 8/02 Quick-Start Installation Instructions Note: The

More information

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing) 1 X-Flow Mass Flow Controller Flow Range from 0.8 ml/min to 20 l/min Target Markets Laboratory and Process Instrumentation Pharma / Bio-Pharma Equipment Air Quality Monitoring Systems Furnace and Coatings

More information

DPC-30 DPC-100. Reference Manual

DPC-30 DPC-100. Reference Manual DPC-30 DPC-100 Reference Manual 1. Introduction 1.1 Description The Martel DPC Digital Pneumatic Calibrator improves upon traditional dial gauge pneumatic calibrators. The Martel DPC improves accuracy,

More information

Manual Actuated Boiler Blowdown Valves

Manual Actuated Boiler Blowdown Valves Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety

More information

C-Flow Coriolis Mass Flow Meters

C-Flow Coriolis Mass Flow Meters Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM

More information

Model 130M Pneumatic Controller

Model 130M Pneumatic Controller Instruction MI 017-450 May 1978 Model 130M Pneumatic Controller Installation and Operation Manual Control Unit Controller Model 130M Controller is a pneumatic, shelf-mounted instrument with a separate

More information

Coriolis Mass Flow Meter

Coriolis Mass Flow Meter Coriolis Mass Flow Meter TMFW Series Mini Type Coriolis Mass Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com;

More information

Liquids and Gases Gas & Liquid

Liquids and Gases Gas & Liquid mini CORI-FLOW Compact Coriolis Mass Flow Meters & Controllers for Liquids and Gases Gas & Liquid Contents Facts about Coriolis Flow Measurement and Control 3 Mass Flow Meters 4 Mass Flow Controllers 8

More information

The Ins and Outs of I/P Transducers

The Ins and Outs of I/P Transducers The Ins and Outs of I/P Transducers By Mark B. Levine, ControlAir Inc. General description I/P transducers are versatile instruments that use an electrical control signal to proportionally regulate gas

More information

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet: OXY Integral INTERCON ENTERPRISES INC Tel: 800 665 6655 Fax: 604 946 5340 E-Mail: sales@intercononline.com Internet: www.intercononline.com Manual Integral 2006 1 INDEX 2-3 PREFACE 4 INTRODUCTION 5 Principle

More information

GM Series Dual-Block Multi-Function Gas Control Valves

GM Series Dual-Block Multi-Function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator. LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the

More information

CORI-FILL. Coriolis Mass Flow Meter Based Compact Fluid Dosage Assembly. Fulfilling your needs

CORI-FILL. Coriolis Mass Flow Meter Based Compact Fluid Dosage Assembly. Fulfilling your needs CORI-FILL Coriolis Mass Flow Meter Based Compact Fluid Dosage Assembly Fulfilling your needs This is CORI-FILL Introduction Bronkhorst Cori-Tech B.V. manufactures Coriolis Mass Flow Meters and Controllers

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital

More information

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER THERMAL MASS FLOW METER s Series Thermal Mass Flow Meters provide accurate and reliable flow measurement for natural gas, compressed air, and other industrial gas applications. Natural Gas Compressed Air

More information

Design Features. General Description

Design Features. General Description Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

Dual Solenoid Gas Valve Installation

Dual Solenoid Gas Valve Installation Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions

More information

SPECIFICATIONS ATTENTION

SPECIFICATIONS ATTENTION VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane

More information

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301 THE HF-300 SERIES Operating and Service Manual Series includes all variants of HF-300/301 Issue A July 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 3.1. Spring Loaded...

More information

3.0 Pressure Transmitter Selection

3.0 Pressure Transmitter Selection 3.0 Pressure Transmitter Selection Each Tronic Line pressure transmitter has different features to meet specific performance, environmental, and price requirements. It is not possible to describe every

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Direct flow measurement with CMOSens technology for nominal flow rates from 0 ml N to 0 l N High accuracy and reproducibility Ingress protection IP Type can be combined

More information

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex Data Sheet DS-TMF-586Ex-MFC-eng TMF-Zone Brooks TMF-Zone Models 586-Ex/5864-Ex Customer Benefits Assured process accuracy and repeatability Long-term reliability Reduced maintenance CE certified Improved

More information

Model PDT Dewpoint Transmitter

Model PDT Dewpoint Transmitter Model PDT Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk

More information

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL - Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL - Table of Contents 1. Introduction 3 2. Instrument Setup 4 2.1 Instrument Checklist 4 2.2 Optional Accessories 4 2.3 Gas Concentration Ranges Available

More information

2/2-Way Proportional Valve (motor-driven)

2/2-Way Proportional Valve (motor-driven) 2/2-Way Proportional Valve (motor-driven) Type 3280 can be combined with Seat valve with stepper motor - actuator isolated from flow path Excellent range (1:100) Low power consumption Fast response Orifice

More information

Mass Flow Meter (MFM) for Gases

Mass Flow Meter (MFM) for Gases 873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital

More information

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator. PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

Constant Pressure Inlet (CCN) Operator Manual

Constant Pressure Inlet (CCN) Operator Manual Constant Pressure Inlet (CCN) Operator Manual DOC-0125 Revision J 2545 Central Avenue Boulder, CO 80301-5727 USA C O P Y R I G H T 2 0 1 1 D R O P L E T M E A S U R E M E N T T E C H N O L O G I E S, I

More information

Mass Flow Meter (MFM) for gases

Mass Flow Meter (MFM) for gases Mass Flow Meter (MFM) for gases Type can be combined with Inline MFM for nominal flow rates from 25 l N /min to 1,500 l N /min; 1/4 to 3/4 High accuracy Fast settling time Fieldbus option Special version

More information

Instruction Manual Contact Pressure Vacuum Gauge

Instruction Manual Contact Pressure Vacuum Gauge MS10 Instruction Manual Contact Pressure Vacuum Gauge Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description Smart-Trak Model 100 High Performance Digital Gas Mass Flow Meters and Controllers Features Measure & control gas mass flow rates up to 1000 slpm True digital performance provides high accuracy and great

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from ml N /min to 0 l N /min Applicable for aggressive gases Fieldbus option Type 870 can be combined with...

More information

User s Guide. Pressure Controller for liquid delivery systems

User s Guide. Pressure Controller for liquid delivery systems Flow Control User s Guide Pressure Controller for liquid delivery systems Precise Pressure Control throughout the experiment Flow control Compatible with any perfusion system Ideal for Small Volume Delivery

More information

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions Flow Meter with multiple functions for gases and liquids M3 The M-series Flow Meter, with its versatile and user-friendly

More information

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr A DIVISION OF THE FREDERICKS COMPANY 2400 PHILMONT AVE. HUNTINGDONVALLEY, PA 19006 PARTS LIST 1 3 4 2 # QTY ITEM DESCRIPTION

More information

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) THE BP-301 SERIES Operating and Service Manual Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) Issue B October 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation...

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The LDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

ACCU-PULSE Installation and Operation Instructions

ACCU-PULSE Installation and Operation Instructions ACCU-PULSE Installation and Operation Instructions Pump Discharge Installation: Chargeable Models Step 1: Mounting Position Mount ACCU-PULSE as close to the pump discharge as possible to absorb the pulse

More information

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm) Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless

More information

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST OIL-LESS TYPE IMPORTANT: PLEASE READ CAREFULLY BEFORE STARTING OPERATIONS. THE CONTENTS ARE FOR GENERAL INFORMATION OF ALL THE SIMILAR MODELS. Record

More information

GILMONT ACCUCAL FLOWMETERS

GILMONT ACCUCAL FLOWMETERS OPERATING MANUAL GILMONT ACCUCAL FLOWMETERS 28W092 Commercial Ave. Barrington, IL U.S.A. 60010-2392 (847) 381-4888 (847) 381-7053 (Fax) 800-962-7142 www.barnant.com e-mail: barnant@barnant.com A-1299-0766

More information

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401 THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special

More information

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com

More information

KOBOLD KSM FLOWMETER. User Instructions

KOBOLD KSM FLOWMETER. User Instructions KOBOLD KSM FLOWMETER User Instructions USA 1801 Parkway View Drive Pittsburgh, PA 15205 PH 412-788-2830 Canada 9A Aviation Point Claire, QC H9R 4Z2 PH 514-428-8090 www.koboldusa.com KSM_manual_08-10 Table

More information

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions L 100 Bubble-Tube Level System Installation, Operation and Maintenance Instructions Figure 1 Contents Section Description Page 1.0 Introduction 2 2.0 Specifications 3 3.0 Installation 3 4.0 Warranty 6

More information

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc. The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is

More information

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER Features ±0.01% FS Measurement & Control Accuracy ±0.001% /ºC Thermal Stability Pressure Ranges from ±1 psid to 1200 psia Applications Barometric Measurement

More information

Maintenance Manual. Liquid Level Transmitter CT801-SI, CT801-TA

Maintenance Manual. Liquid Level Transmitter CT801-SI, CT801-TA CT801-SI, CT801-TA Maintenance Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Maintenance Manual CT801-SI, CT801-TA

More information

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual Air Bubbler Depth Gauge DG2200 Installation and Reference Manual Rev. 3.2.2 06/2011 Installation and Reference Manual Page 2 Contents Chapter 1: Installation and Overview... 3 1.1 DG2200 Location Diagram...

More information

Malema Sensors M-2700 Integrated Ultrasonic Flow Meter

Malema Sensors M-2700 Integrated Ultrasonic Flow Meter Malema Sensors M-2700 Integrated Ultrasonic Flow Meter Operating Instructions TABLE OF CONTENTS Introduction............... 3 Storage and Handling........... 4 Installation Instructions........... 4 Start

More information

Technical Information Conducal CLY421

Technical Information Conducal CLY421 TI00496C/07/EN/01.12 71142150 Products Solutions Services Technical Information Conducal CLY421 Conductivity calibration set for ultrapure water applications Factory calibrated measurement box Certified

More information

Bermad Pressure Reducing. Model: 42T

Bermad Pressure Reducing. Model: 42T Bermad Pressure Reducing Pilot Operated Pressure Control Valve Model: 42T Installation Operation Maintenance Manual (IOM) REV. 27.7.17 Page 1 of 12 Safety First BERMAD believes that the safety of personnel

More information

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Page 1 of 12 Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control

More information

Scald Protection Three-Way Thermostatic Mixing Valve

Scald Protection Three-Way Thermostatic Mixing Valve CALEFFI www.caleffi.com 383.04 Scald Protection Three-Way Thermostatic Mixing Valve Copyright 00 Caleffi 3 Series Installation, commissioning and servicing instructions Function Scald Protection Three-Way

More information

OPERATING INSTRUCTIONS Pressure Control System PCS-20 through PCS-100

OPERATING INSTRUCTIONS Pressure Control System PCS-20 through PCS-100 107 W. Main Street Worthington, PA 16262 Phone: 724.297.3416 Fax: 724.297.5189 http://www.airtak.com OPERATING INSTRUCTIONS Pressure Control System PCS-20 through PCS-100 12-2007 TABLE OF CONTENTS PAGE

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual WIKA FLR-SBDF / BLR-SBDF Magnetic Level Transmitter (Please retain for future usage) Contact: Gayesco-WIKA USA, L.P. 229 Beltway Green Boulevard Pasadena, TX 77503 www.wika.com

More information

deltaflowc deltaflowc Venturi or Probe

deltaflowc deltaflowc Venturi or Probe deltaflowc Mass Flowmeter for Gases - Multivariable with ultra fast dp, p and T-sensors - Compact, accurate and user-friendly - Ideal for OEMs deltaflowc Venturi or Probe Precise mass flow metering deltaflowc

More information

OFFICINE OROBICHE S.p.A. 1/9

OFFICINE OROBICHE S.p.A. 1/9 OFFICINE OROBICHE S.p.A. 1/9 INSTRUCTIONS MANUAL FOR LEVEL SWITCHES SERIES 7000 mod. 7250 AND 7400 Electric 1. INSTRUMENT DESCRIPTION Series 7000 level switches have been designed for external lateral

More information

Mass Flow Controller (MFC) for gases. Inline MFC for nominal flow rates from 25 I N. /min to I N

Mass Flow Controller (MFC) for gases. Inline MFC for nominal flow rates from 25 I N. /min to I N Mass Flow Controller (MFC) for gases Type 8626 can be combined with Inline MFC for nominal flow rates from 25 I N /min to I N /min; 1/4 to 3/4 High accuracy Fast settling time Fieldbus option Special version

More information

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator. RHPS Series RD(H)F40 User Manual Read the complete manual before installing and using the regulator. 2 WARNING Before removing a regulator from the system for service, you must depressurize system purge

More information

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale EPR-3000 High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale General Specifications PRECISE CONTROL UP TO 3000 PSI The Equilibar EPR-3000 dual valve pressure controller

More information

Instruction Manual Differential Pressure Transmitter

Instruction Manual Differential Pressure Transmitter DE61 Instruction Manual Differential Pressure Transmitter Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information

Bypass Mass Flow Controller (MFC) for gases

Bypass Mass Flow Controller (MFC) for gases Bypass Mass Flow Controller (MFC) for gases Bypass MFC with Capillary technology for nominal flow rates from ml N /min to l N /min Suitable for aggressive gases Fieldbus option Type 870 can be combined

More information

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN Type 3709 Pneumatic Lock-up Valve Translation of original instructions Mounting and Operating Instructions EB 8391 EN Edition July 2017 Note on these mounting and operating instructions These mounting

More information

Variable Area Flow Meters

Variable Area Flow Meters PDF Published May, 04 Variable Area Flow Meters Chemline F Series Variable Area Flow Meters are ideal for plastic piping. They provide a combination of accurate visual flow rate measurement and clear flow

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Type 8626 can be combined with Inline MFC for full scale rates from 25 l N /min to 1.500 l N /min; 1/4 to 3/4 High accuracy Short settling time Fieldbus option Type

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features ANALOG MASS FLOW CONTROLLERS Model AF mass fl ow controllers are designed to indicate fl ow rates and control set fl ow rates of gases. Each of these units incorporates an advanced straight tube sensor

More information

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

T EK-COR 1100A. Coriolis Mass Flowmeter.   FLOW. Technology Solutions Technology Solutions T EK-COR 1100A Coriolis Mass Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction There can often be more than one type

More information

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6 P9000 High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESCRIPTION The P9000 Series is a range of advanced,

More information

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO 97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and

More information

In Vivo Scientific, LLC INSTRUCTION MANUAL

In Vivo Scientific, LLC INSTRUCTION MANUAL CO 2 Controller In Vivo Scientific, LLC INSTRUCTION MANUAL CONTENTS CONTENTS...1 ABOUT THIS MANUAL...2 INTRODUCTION...2 Cautions and Warnings...2 Parts List...2 Unpacking...2 INSTRUMENT DESCRIPTION...3

More information

Technical Data Sheet MF010-O-LC

Technical Data Sheet MF010-O-LC Technical Data Sheet MF010-O-LC - 1 - 1. Properties The oxygen measuring system MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 C. It is particularly suitable for the

More information

Digital Vacuum Regulator

Digital Vacuum Regulator Temperature Control for Research and Industry Digital Vacuum Regulator User s Manual Model 300 INDEX SECTION PAGE 1. QUICK OPERATING INSTRUCTIONS........................... 3 Safety Notices.................................................

More information

Float Operated Level Controllers

Float Operated Level Controllers CONTENTS Float Operated Level Controllers IM0015 Nov. 2014 PAGE Introduction 1 Scope 1 Description 1 Specification 1 Control Installation 2 INTRODUCTION Side Mount Back Mount Prior to installing, the instructions

More information