1 Instruction Manual CORI-FILL Setting up (mini) CORI-FLOW instruments for filling applications Doc. no.: D Date: ATTENTION Please read this Instruction Manual carefully before installing and operating the instrument. Not following the guidelines could result in personal injury and/or damage to the equipment.

2 Disclaimer Disclaimer Because of the various hardware and software environments into which Bronkhorst software may be put, this software and the accompanying files are "as is" and without warranties as to performance of merchantability or any other warranties whether expressed or implied. Bronkhorst High-Tech B.V. is not responsible for lost profits or revenue, loss of use of the software, loss of data, costs of recreating lost data, the cost of any substitute equipment or program, or claims by any party other than you. Although the equipment is thoroughly tested, Bronkhorst High-Tech B.V. takes no responsibility for hardware or software failures which could result in personal injury and/or damage to any customer equipment. Bronkhorst strongly recommends a backup to be made before any software is installed. Although every attempt has been made to make Bronkhorst software virus free, there is no warranty for software viruses. The fact that you are using the program indicates that you understand and agree to these terms. Copyright 2018 Bronkhorst High-Tech B.V. All rights reserved. This documentation is protected by copyright. Subject to technical and optical changes as well as printing errors. The information contained in this document is subject to change at any time without prior notification. Bronkhorst High-Tech B.V. reserves the right to modify or improve its products and modify the contents without being obliged to inform any particular persons or organizations. The device specifications and the contents of the package may deviate from what is stated in this document. Symbols Important information. Discarding this information could cause injuries to people or damage to instrumentation or installation. Helpful information. Additional info, available on the internet or from your local sales representative. 2 Instruction Manual CORI-FILL D

3 Table of contents 1 Introduction Scope of this.... manual General description Dosing methods Mode A: on/off control based on... measured batch size Mode B: on/off control based on... time and.... measured batch size Mode C: proportional control Other documents FlowPlot.. and..... FlowDDE Installation 3.2 FlowDDE FlowPlot Readout. in... mass flow..... or.... volume flow Adjust instrument capacity (fs.... range) Capacity. settings in... combination with..... shut-off valves Capacity. settings for.... proportional control Filter settings and..... counter functionality Preparing.... the..... counter for.... batch dosing Analog operation On/off control using a.. shut-off valve Setting up... optional on/off batch dosing conditions Filter settings 8.3 Minimum.. capacity settings Difference.... between on/off control [mode A]... &...[MODE B] On/off control [mode A] On/off control [mode B] Using hold... current for.... energy saving with..... shut-off valves Proportional filling [mode C] Counter control gain Proportional..... filling example Controller.. options Controller.. settings example Troubleshooting Service D Instruction Manual CORI-FILL 3

4 1 Introduction 1.1 Scope of this manual This manual describes how to use CORI-FILL and how it should be used for maximum performance. In this manual CORI- FILL will be explained from the context of the Bronkhorst software tools FlowDDE and FlowPlot. Please read the fieldbus manuals for fieldbus communication and settings. 1.2 General description The CORI-FILL technology is an integrated batch dosing feature within (mini) CORI-FLOW instruments. By measuring a flow rate during a certain time frame an amount of mass or volume can be obtained with the counter functionality. By setting the counter to count up or count up to limit the flow meter can be used as a batch meter or batch controller. The on board PID-controller can be used to directly control the batch counter, using a proportional valve or liquid pump. It s also possible to control the counter with a shut-off valve. Flow Measurement * Time = Counter value in mass or volume 1.3 Dosing methods Mode A: on/off control based on measured batch size Available from firmware version 8.32 or higher (released in ) Used for short dosing time s Shut-off valve is on-off steered based on mass or volume The (mini) CORI-FLOW instrument uses its mass/volume measurement to correct setpoint level for the next batch, therefore compensating for overshoot with the overrun correction Overrun correction resolution 20ms Suitable for repeatable conditions, stable after 3 batches 4 Instruction Manual CORI-FILL D

5 1.3.2 Mode B: on/off control based on time and measured batch size Only available for mini CORI-FLOW M12, M13 M14 & M15 with firmware version 8.40c or higher (released in ) Used for short dosing times s Shut-off valve is on-off controlled during a certain time frame The mini CORI-FLOW instrument uses its flow measurement to correct the dosing time for the next batch, therefore compensating for overshoot with the overrun correction Overrun correction resolution <3.6ms Suitable for repeatable conditions, stable after 3 batches Firmware version 8.40c should be upgraded to firmware version 8.41d for optimal functionality Mode C: proportional control Used for longer dosing times >2s Valve or pump control on actual mass measurement First time right dosing control no overshoot Sufficient supply pressure needed for proper flow control when using a control valve Mode A On-Off control on batch size Mode B On-Off control on time and batch size Mode C Proportional batch control Dosing time 0.5-5s 0.1-5s > 2s Correction resolution 20ms < 3.6ms 20ms Works with: Shut-off valve Yes Yes No Control valve No No Yes Pump No No Yes Control methode Batch size compensation Time & batch size compensation Proportional batch size control D Instruction Manual CORI-FILL 5

6 2 Other documents Basic instructions Document Instruction manual mini CORI-FLOW Dimensional drawings Document Dimensional drawing M12 / M13 / M14 Mass Flow Meters - compression type weld adapters - Document Dimensional drawing M15 Mass Flow Meters Document Instruction manual CORI-FLOW Document Dimensional drawing M5X CORI-FLOW Advanced instructions Hook-up diagrams Document Instruction manual Operational instructions for digital multibus Mass Flow/Pressure instruments Document Instruction manual FLOW-BUS Interface for digital multibus Mass Flow/Pressure instruments Document Instruction manual PROFIBUS DP slave interface for digital multibus Mass Flow/Pressure/Gateway instruments Document Instruction manual DeviceNet slave interface for digital multibus Mass Flow/Pressure instruments Document Instruction manual RS232 Interface with FLOW-BUS protocol for digital multibus Mass Flow/Pressure instruments Document Instruction manual Modbus slave interface for digital Mass Flow/Pressure instruments Document / / Hook-up diagram FLOW-BUS Interface Document / / Hook-up diagram PROFIBUS DP Interface Document / / Hook-up diagram DeviceNet Interface Document / / Hook-up diagram General (Analog I/O and RS232 Interface with FLOW-BUS protocol) Document / / Hook-up diagram Modbus Interface These documents can be found at For instructions about how to install the instrument it is advised to read the mini CORI-FLOW or CORI-FLOW manual. For accurate dosing performance it is advised to follow the instructions in the Low Flow handling documentation. 6 Instruction Manual CORI-FILL D

7 3 FlowPlot and FlowDDE 3.1 Installation Follow the on-screen instructions when installing FlowPlot and FlowDDE. The default installation folder is: C:\Program files\bronkhorst\flowplot and C:\Program files\bronkhorst\flowdde. 3.2 FlowDDE First start-up FlowDDE, than start-up FlowPlot. Start FlowDDE through the Start menu: Start >> Programs >> Bronkhorst >> FlowDDE When FlowDDE is started and indicating that it is ready for any client, the main window is shown. Select: Communication >> Communication Settings and select the COM-port on your PC which is connected to the instrument. Select: Communication >> Open communication and wait until the message Server is active and ready for any client appears on the screen. Figure 1 - The FlowDDE main window for communication between instrument and MS-Windows environment. Start FlowPlot through the Start menu: Start >> Programs >> Bronkhorst >> FlowPlot At the screen Select parameters connect the colored lines to: FlowDDE/FlowDDE2 channel number (typically = 1) parameter number e.g. like in picture on the right. Press OK to go to the main screen. It is possible to use up to 8 plot lines in different (predefined) colors to watch the dynamic behavior of these signals in time. Mode 18. RS232 (or mode 0 : bus & RS232) should be selected to enable your PC to take over setpoint control for the Coriolis instrument. For more detailed information about FlowPlot and FlowDDE consult the FlowPlot and FlowDDE manuals; these documents can be downloaded from D Instruction Manual CORI-FILL 7

8 3.3 FlowPlot In the beginning this screen is empty This screen shows the selected parameter value sizes as a function of the time to get an impression of the dynamic flow (and other parameter) behavior. Counter value (100% is counter limit) Density (100% = 2000 kg/m3-0% = 0 kg/m3) Temperature (percentage = C) Setpoint (wanted value; 100% = FS = capacity) Measure (actual flow; 100% = FS = capacity) Controller output value Pressing Instrument settings will pop-up another screen for adjusting the instrument settings. 8 Instruction Manual CORI-FILL D

9 4 Readout in mass flow or volume flow The (mini) CORI-FLOW mass flow meters/controllers operate according to the Coriolis principle. The instrument can simultaneously measure mass flow, temperature and density. Mass flow can be converted to volume flow by using the measured (actual) density. At the Tab Basic it is possible to prepare the instrument for mass flow readout like: g/h or kg/h or volumetric readout values like: l/min or ml/h. The counter will automatically switch to similar units; g or ml etc. Volumetric flow options: To measure in volume, select Volume Flow, the density should be specified manually. When Actual Volume Flow is selected, the actual measured density will be used to calculate from mass to volume flow. Note: this is only possible with the mini CORI-FLOW series and the CORI-FLOW M55. Normal Volume Flow and Standard Volume Flow are typical gas flow units. It will be necessary to enter the density at normal 0 C and 1 atm. or at standard 20 C and 1 atm. conditions to be able to get the correct volumetric readout D Instruction Manual CORI-FILL 9

10 5 Adjust instrument capacity (FS range) In the Tab Basic it is possible to (re)range the full scale value of the instrument. A value between the shown minimum and maximum can be selected. For the best performance it's advised to optimize the Capacity. Especially when proportional filling is used, this will result in a minimum loss of AD-DA resolution. At [Capacity and unit] a full scale value can be entered with digits or by using the slider. Depending on the instrument the full scale value will be a value between a minimum and a maximum capacity. The optimum value depends on the amount to be dosed and will be indicated as 100% value in FlowPlot. Analog output signals will also be re-scaled for this new capacity: 4-20mA: 20 ma will correspond with 100% = FS capacity value. 5.1 Capacity settings in combination with shut-off valves Full scale value in kg/h = (Batch (g) / Time (s)) * 3.6 When the system is perfect (degassed), a square wave should be seen at the flow output. If the batch cannot be reached within the specified time, the inlet pressure should be increased. 5.2 Capacity settings for proportional control For proportional control an estimate should be made. System response (system and PID-Controller settings) Dosing time Counter control gain Exponential filter settings As rule of thumb: Full scale value in kg/h = 1.2 * (Batch (g) / Time (s)) * 3.6 Please mind that this is a theoretical approach, it is meant to give you an indication of the full scale value. In practice the full scale value will need to be a little higher, because of the opening and closing time of the actuator. The counter control gain value will also influence the total dosing time (see section Counter control gain). Please note this can only be used for proportional filling. When a shut-off valve is used, the inlet pressure will determine the flow rate. Therefore it is very important to use a correct and stable inlet pressure. For information regarding Auto Zero please consult document: operation instructions digital instruments: Instruction Manual CORI-FILL D

11 6 Filter settings and counter functionality When a Physical Flow is applied to the Sensor the sensor will measure flow. This signal will go through the Exponential smoothing Filter. When the absolute exponential smoothed signal is greater than the threshold (minimum capacity * 0.02) the flow signal will be integrated and shown as the Counter Value. When the filter settings are switched off (value= 1) or close to off, the threshold might be too low. Meaning the counter could start counting RMS (root mean square) noise instead of actual flow. To prevent this, the minimum capacity should be increased. Schematic figure counter functionality Filter values for proportional batch control Typical filter values are shown in the red box. Please note that these filter settings have to be adjusted per CORI-FILL application. For proportional control these values can be used. For fast dosing applications (<2 sec) with shut-off valves these have to be switched off [value 1]. Please find information regarding optimal filter settings for On-Off dosing and minimum capacity level at section On/off control using a shut-off valve. For fast proportional batch control (<5 sec) it is advised to use the settings explained in section Proportional filling [MODE C]. The flow signal shown as output can be extra filtered by the Dynamic Display factor and the Static Display factor these filters will not influence the Counter Value. All filters have values between 0 1. Values close to 0 means more filtering. Filters are switched off when the value = 1.0 The adaptive filter setting will not be used. Value = 0 This figure shows the difference between filtered and unfiltered signals. Between the threshold lines the noise signals are shown. By using unfiltered signals the minimum capacity should be increased to make sure that the noise will not affect the counter. By increasing the minimum capacity the threshold level will also increase. Please see section Minimum capacity settingsfor more information D Instruction Manual CORI-FILL 11

12 7 Preparing the counter for batch dosing After setting the counter mode in [up to limit] a limit can be entered. The overrun correction and counter control gain need to be set according the actuation type. Please note that these parameters will only work when the (mini) CORI-FLOW is controlling the actuator. For more details regarding these settings please see sections 8, 9 and 10. The counter control gain is of no influence when batch dosing is performed with a shut-off valve. [New setpoint on limit] should be enabled. The [New setpoint] value will normally be = 0% (= setpoint when reaching the batch). [Output] can be set as shown left, but will not have any effect on batching. [Reset] will determine the enabled sources for resetting the counter. Following options are available: FLOW-BUS (Field Bus and RS232 Keyboard (using the button on the instrument) Ext. (external input on optional pc-board) Analog setpoint (external setpoint input) By pressing [reset counter] the counter value will be set to 0. After applying a certain setpoint the counter (batch) will be restarted. Please find fieldbus settings in the according fieldbus manuals. 7.1 Analog operation When this counter reset source has been enabled, the analog input for the setpoint (normally 0..5V/0..10V/0..20mA/4..20mA), will be used. When the setpoint input will be set to 0, the counter will be reset. When the setpoint will be set to a value >0, the batch counter will restart the next batch. When using this option in on-off dosing mode (with shut-off valves) the setpoint value is irrelevant, as long as it is >2%. For proportional filling with a proportional valve the setpoint value is important! Example analog operation: Analog setpoint change for reset and starting next batch Flow rate Correct settings via RS232 (just once) or 12 Instruction Manual CORI-FILL D

13 8 On/off control using a shut-off valve For fast dosing applications (<2 sec) shut-off valves are used. The mini CORI-FLOW instruments are able to operate shut-off valves in two modes: MODE A: On-Off control on batch size is available from Firmware version 8.32 (31-Aug-2010) MODE B: On-Off control on time & batch size is available from Firmware version 8.40C (11-Dec-2015) Firmware version 8.40c should be upgraded to firmware version 8.41d for optimal functionality. 8.1 Setting up optional on/off batch dosing conditions For optimal accuracy it is very important that the following conditions are taken into account: Stable and the correct inlet pressure should be provided The inlet pressure will determine the flow velocity. Too high pressure will lead to overshoot and unstable results, too low pressure will result in non-achieved batch limits. The system or liquid should not contain any gas bubbles since they will work like an expansion vessel. This leads to slow system response times and flow measurement when the valves are closed, because the gas bubbles will be filled up with liquid due to the inlet pressure. Therefore a degasser is recommended especially in applications within and ms dosing range. The amount of piping, reducers, connections and t-parts should be restricted to the absolute minimum. Use tubing/piping size which is appropriate to the flowrate. (mini) CORI-FLOW should be auto zeroed at actual process conditions. 8.2 Filter settings For fast batch dosing results it is important to turn off the filter settings and increase the minimum capacity. When the filter settings are turned off (value 1) the instrument is very fast, however also sensitive for disruptions such as vibrations, pulsations and RMS noise. Therefore the minimum capacity has to be increased and it is important to mount the instrument on a vibration free environment on the supplied mass block and dampeners D Instruction Manual CORI-FILL 13

14 8.3 Minimum capacity settings When the filter settings are turned off, the expected minimum capacity should be increased to the values shown in the table below. These values are determined in a vibration free environment. If due to vibrations the (mini) CORI-FLOW instrument keeps counting up/down (when the valves are closed) the minimum capacity should be increased or the vibrations should be avoided. Instrument M12 M13 M14 M15 Expected minimum capacity <14g/h <140g/h <1.4kg/h <6kg/h By FlowDDE or Fieldbus the minimum capacity can be increased. Please see the following example for FlowDDE. 14 Instruction Manual CORI-FILL D

15 9 Difference between on/off control [MODE A] & [MODE B] The difference between MODE A and MODE B on-off control is the correction algorithm. For on-off control on batch size [MODE A], the valve will be open until the limit (in gram or ml) is reached. The counter value will be corrected by the overrun correction to compensate for overshoot. This functionality has a correction resolution of 20 ms. For on-off control on time & batch size [MODE B], the valve will be open for a predetermined time frame (max dosing time), the counter value will be used to adjust the dosing time to achieve the desired (batch) limit. The dosing time correction has a resolution of <3.6 ms. Example in practice: Limit (batch) = 200 Dosing time = 500 ms Flow = 0.4 /ms = 0.4g/s = 1440 g/h On-off control on Flow [MODE A] Accuracy: - 0.2% Rd + ZS - 20ms resolution on correction - RMS noise On-off control on Time [MODE B] Accuracy: - 0.2% Rd + ZS - <3.6ms resolution on correction - RMS noise MODE A MODE B D Instruction Manual CORI-FILL 15

16 9.1 On/off control [MODE A] For on-off control on batch size, the valve will be open until the set limit (in gram or ml) is reached. The counter value will be corrected by the overrun correction to compensate for overshoot or undershoot. This functionality has correction resolution of 20 ms. Please see the following schematic overview for more detailed information regarding the process steps of PC-board. Dosing Example: Counter limit = gram Measured counter value = 9.98 gram Overrun correction = 0.8 Counter control gain = 0 because this has no function in combination with shut-off valves Reset counter = will reset/restart the counter value Setpoint value = >2% because a shut-off valve will be either open or closed Correction resolution = 20ms Overrun correction (on-off control on flow): The [Overrun Correction] is a self-learning, continuous and fully automatic principle. After every [Reset Counter] command it will determine the optimal Valve Closing Value in mass or volume to achieve the desired limit. A correction value between 0 and 1 can be entered. Therefore, when a value is entered, the system will close the shut-off valve a fraction earlier or later, depending on overrun or underrun measured by the [Counter Value]. Higher values result in fast correction and less cycles before desired limit is reached. An overrun correction of 0.8 has proven to be a proper functioning value. The closing value for the valve is calculated with the formula below. Underneath the formula a filled out example is shown based on a [Limit] of 10 gram and an [Overrun Correction] of 0.8. For the first dosing sample: Closing Value [n-1] = Counter Limit C losing Value[n] = Closing Value[n-1] Overrun Correction * ( Counter Value Counter Limit ) 10 = * ( 0-10 ) 2.4 = * ( ) 2.78 = * ( ) 2.76 = * ( ) Measured [Counter Values] are the main input for this formula. The used [Counter Values] are measured data. inlet pressure is usually too high. Please lower the inlet pressure. 16 Instruction Manual CORI-FILL D

17 9.2 On/off control [MODE B] For on-off control on time & batch size, the valve will be open for a predetermined time frame [Maximum Allowed Dosing Time], the counter value will be used to adjust the dosing time to achieve the desired (batch) limit. The dosing time correction has a resolution of <3.6 ms. making it more accurate, faster and stable than the correction resolution of MODE A. Additional Parameters: Within this firmware the parameters for time control [P359 Maximum Allowed Dosing Time] and [P360 Most Recent Dosing Time] are introduced. Both parameters will use a unit type in seconds. CORI-FILL MODE B is active if parameter 359 has a value > 0 seconds (e.g. 0.5s) and inactive at value 0. With parameter 360 the [Most recent dosing time] can be shown. When the functionally is inactive the other CORI-FILL modes A & C can be used. Please note: the first dosage will use the full predetermined [maximum allowed dosing time] as reference. When the reference point is determined the correction functionally will adjust the dosing time. Please see the following schematic overview for more detailed information regarding the process steps of PC-board. Overrun correction (on-off control on time): The [Overrun Correction] is a self-learning, continuous and fully automatic principle. After every [Reset Counter] command it will determine the optimal [Dosing Time] based on the measured Counter Value. A correction value between 0 and 1 can be entered. Higher values result in fast correction and less cycles before desired limit is reached. An overrun correction of 0.8 has proven to be a proper functioning value. The [Dosing Time] is calculated with the formula below. On the next page the formula a filled out example is shown D Instruction Manual CORI-FILL 17

18 Starting values: [Limit] =250 [Max Dosing Time] = 1.5s [Overrun Correction] =0.8 Time Correction [n-1] =1 (this value is used for the first correction) Time Correction [n] =Time Correction [n-1] Overrun Correction*[Time Correction [n-1]-counter Limit/Counter value] Dosing Time [n] =Dosing Time [n-1] * Time Correction[n] Dosing sequence: Step 1: Valve is opened for 1.5 seconds [Max Dosing Time] During the [Max Dosing Time] a value of 1200 is measured [Counter Value] Step 2: = *( 1-250/1200 ) = 15 * Step 3: = *( /440.8 ) = * Step 4: = *( / ) = * Repeating these steps will lead to the following Counter Values: Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step The dosing sequence will be restarted when [Max Dosing Time] is adjusted. 9.3 Using hold current for energy saving with shut-off valves In order to open the valve (open current) the output signal can be set at valve maximum. The hold signal (current) can be separately set at valve open. These values might differ for each type of valve, depending on e.g. the coil. Using the energy saving option will result in less power dissipation at the valve and thus in lower temperature. For fluids sensitive to evaporation/boiling, this option might be very useful. Valve output: Without holding current With holding current 18 Instruction Manual CORI-FILL D

19 10 Proportional filling [MODE C] In the Alarm & Count tab, the counter setting can be found. The counter will count the total amount of flow passing through the instrument. The counter has three modes: [Off], [Up] and [Up to limit]. For filling applications [Up to limit] has to be selected. In order to perform a dosage a setpoint value (e.g. 100%) has to be selected. The setpoint value is related to the full scale value. Setpoint can be changed once the limit has been (or will be) reached. By enabling [new setpoint on limit] and set it at 0.0%, the dosing set-up is created. Select [reset counter] to perform a dosage. (When the desired limit has been reached, setpoint will be set to zero) 10.1 Counter control gain The value set as counter control gain is related to a percentage. This percentage will be connected to the Counter Limit. When a certain percentage of the counter limit is reached the proportional actuator will be slowly forced to stop/close due to a decreasing setpoint level. This is needed in order to approach the counter limit carefully and avoid overshoots. The point of slowing down can be set by means of counter control gain. This value can be changed from The following formula is used: In the example on the left, counter control gain = 2, which means that the setpoint will go downwards after reaching 50% of the counter limit (10 g). When reaching 5g, the counter will force the controller to decrease its setpoint down to 2% (automatically controlled by an additional P- controller for the counter). The last part of the batch will be dosed at 2% flow rate of the capacity. An example is shown at chapter 10.2 proportional filling example.. Fast and accurate proportional filling is possible, therefore it is necessary to set a few controller options, such as FS value, counter control gain and the PID-Kp value. See section Controller settings example. Counter control gain (X) Counter value where controller will slow down 0 No slowing down; controller stops if limit has been reached 1 0%, so immediately when counter starts running 2 50% of max. limit of counter 3 67% of max. limit of counter 4 75% of max. limit of counter 5 80% of max. limit of counter 10 90% of max. limit of counter 50 98% of max. limit of counter % of max. limit of counter Please try to make sure that the last phase of dosing will be performed at 2% setpoint, otherwise there could be an overdose. If this cannot be avoided or when dosing at 2% will still give an overdose, you might consider enabling the overrun correction or lower the FS value. Both mechanisms can be active at the same time with proportional filling D Instruction Manual CORI-FILL 19

20 10.2 Proportional filling example Test instrument: M14 with Tuthill DGS.23 gear pump; 100% FS = 30 kg/h water. 20 Instruction Manual CORI-FILL D

21 10.3 Controller options Controller options should be set for fast response. Below typical (fast response) settings for a pump controlled by a mini CORI-FLOW instrument. Valve powers, with the learn open function the instrument will determine what the opening/start voltage of the used actuator is (e.g. a valve or a pump). After this value is known the opening response will be adapted to decrease the dead time during setpoint steps from zero. Setpoint slope. Normally = 0, except when PID-Td > 0. PID-Kp: Typical = 10. Increase in range to make controller faster. Decrease to slow down. PID-Ti: Typical = 0.1. Decrease in range to make controller faster. Increase from to slow down. PID-Td: Typical = 0. Increase a little (0 2 sec.) to differentiate dead volume if necessary. Special adjustment for PID-Kp at certain situations for extra speeding up or slowing down. For more detailed information about settings see FlowPlot manual Test instrument: M14 with Tuthill DGS.23 gear pump; 100% = 30 kg/h water. Extra information: The PID scale can be adjusted by double clicking the highest value on the scale as shown below D Instruction Manual CORI-FILL 21

22 10.4 Controller settings example In the table below several controller settings are shown at different batch limits. This test is performed with an M14 mini CORI-FLOW and Tuthill DGS.23 gear pump based on water. - Filters are enabled and set to default values as shown on the next page - The overrun correction is set to zero. - The counter control gain (CCG) has to be adjusted to the batch size. - The PID controller settings vary per application Please note that these values are indicative, it can vary per application. On the next page the flowplot settings are shown for a batch of 20 gram. Important settings: For fast and accurate proportional dosing it is import to create a small overshoot in flow, like 10% as shown on the left. By doing this the Coriolis instrument has more time to control the requested dosage. This is especially important for small dosages. The graph shows a dosage of 20 gram in 5.5 seconds. Please see the correct settings below. An overshoot can be created by increasing the PID-Kp and PID-Ti value. Flowplot settings: These settings are used to dose a batch of 20 gram. 22 Instruction Manual CORI-FILL D

23 11 Troubleshooting Problem Possible cause Action Suddenly a wrong value will be dosed among a sequence of right values when using on-off dosing with shut-off valves. Even when dosing time is very short flow signal is too slow Large deviation on sequential batches (Back) pressure waves caused at valve closing with high force might give erratic reading at (mini) CORI- FLOW. Filter settings might not be optimal. Filter settings might not be optimal. Supply pressure not stable Controller settings not optimal Select a different valve type Make sure to have some volume or dampener between valve and meter Monitor hardware error at alarm info byte at instrument interface to indicate this Monitor counter value at instrument interface to detect this Change filter settings according to the CORI-FILL mode Change filter settings according to the CORI-FILL mode Check and stabilize pressure Increase control stability by optimizing PID settings. Flow signal is >130% Pressure too high Lower the supply pressure Resistance of flow line too low PID-Kp too high FS value (capacity) too low Restrict the flow by using a manual valve Select a lower Kp value Increase the FS (capacity) value Dosed value is not accurate enough Flow meter has wrong zero point Perform new auto-zero Parameter 359 and 360 cannot be found Reset counter command can be given and physical flow can be seen at the outlet but the counter keeps indicating 0 gram or ml Too many gas bubbles in liquid Vibrations disturbing the meter Degas the liquid and purge the flow meter Follow instructions for mounting Flow signal >130% Try to limit flow signal < 130% Dosing time is too short Proportional dosing is too fast Counter control gain too low (Dosing too long at low flow) Reference instrument to check with is not a weighing scale (e.g. volumetric device) Proportional gives too much overshoot Firmware issue Increase dosing time Adjust counter control gain to ensure last part of dosing at 2% Increase counter control gain to dose longer at high flow (more accurate) Use a weighing scale and handle it according to the instructions Lower flow rate (dosing speed) or enable overrun correction Ask your local sales office for options Download the latest version from s Ask your local office for support Firmware version 8.40c should be upgraded to firmware version 8.41d for optimal functionality D Instruction Manual CORI-FILL 23

24 12 Service For current information on Bronkhorst and service addresses, please visit our website: Do you have any questions about our products? Our Sales Department will gladly assist you selecting the right product for your application. Contact sales by For after-sales questions, our Customer Service Department is available with help and guidance. To contact CSD by No matter the time zone, our experts within the Support Group are available to answer your request immediately or ensure appropriate further action. Our experts can be reached at: Bronkhorst High-Tech B.V. Nijverheidsstraat 1A NL-7261 AK Ruurlo The Netherlands 24 Instruction Manual CORI-FILL D

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties Quick Installation Guide Doc nr.: 9.17.052H Date: 10-12-2015 SCOPE OF THIS GUIDE mini CORI-FLOW instruments are highly accurate instruments for measuring and controlling the mass flow rate of liquids and/or

More information

Quick Installation Guide Doc nr.: C Date:

Quick Installation Guide Doc nr.: C Date: Quick Installation Guide Doc nr.: 9.17.093C Date: 13-05-2016 SCOPE OF THIS GUIDE mini CORI-FLOW instruments are highly accurate instruments for measuring and controlling the mass flow rate of liquids and/or

More information

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES SENSORS FOR MASS FLOW AND PRESSURE CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES INTRODUCTION Bronkhorst High-Tech BV is the worldwide pioneer in the field of low flow liquid metering

More information

Precision Mass Flow Meters / Controllers for Liquids and Gases

Precision Mass Flow Meters / Controllers for Liquids and Gases CORI-FLOW TM Precision Mass Flow Meters / Controllers for Liquids and Gases Introduction Bronkhorst Cori-Tech B.V. manufactures precise, compact Mass Flow Meters and Controllers for gases and liquids,

More information

CORI-FILL. Coriolis Mass Flow Meter Based Compact Fluid Dosage Assembly. Fulfilling your needs

CORI-FILL. Coriolis Mass Flow Meter Based Compact Fluid Dosage Assembly. Fulfilling your needs CORI-FILL Coriolis Mass Flow Meter Based Compact Fluid Dosage Assembly Fulfilling your needs This is CORI-FILL Introduction Bronkhorst Cori-Tech B.V. manufactures Coriolis Mass Flow Meters and Controllers

More information

TR Electronic Pressure Regulator. User s Manual

TR Electronic Pressure Regulator. User s Manual TR Electronic Pressure Regulator Page 2 of 13 Table of Contents Warnings, Cautions & Notices... 3 Factory Default Setting... 4 Quick Start Procedure... 5 Configuration Tab... 8 Setup Tab... 9 Internal

More information

Liquids and Gases Gas & Liquid

Liquids and Gases Gas & Liquid mini CORI-FLOWTM Compact Coriolis Mass Flow Meters & Controllers for Liquids and Gases Gas & Liquid Contents Facts about Coriolis Flow Measurement and Control 3 Mass Flow Meters 4 Mass Flow Controllers

More information

Model 601CV. Mass Flow Controller. Product Features:

Model 601CV. Mass Flow Controller. Product Features: Model 601CV Mass Flow Controller Porter s Model 601CV Series II Mass Flow Controller (MFCs) is designed for precise control of virtually all conventional process gases. The MFC consists of a thermal mass

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

Special Documentation Proline Promass 500 Coriolis Flowmeter Modbus RS485 Petroleum Application Package

Special Documentation Proline Promass 500 Coriolis Flowmeter Modbus RS485 Petroleum Application Package MANUAL Special Documentation Proline Promass 500 Coriolis Flowmeter Modbus RS485 Petroleum Application Package SD02137O/06/EN/01.17 Valid as of version 01.01.zz (Device firmware) 71382463 Important All

More information

Liquids and Gases Gas & Liquid

Liquids and Gases Gas & Liquid mini CORI-FLOW Compact Coriolis Mass Flow Meters & Controllers for Liquids and Gases Gas & Liquid Contents Facts about Coriolis Flow Measurement and Control 3 Mass Flow Meters 4 Mass Flow Controllers 8

More information

Armfield Distillation Column Operation Guidelines

Armfield Distillation Column Operation Guidelines Armfield Distillation Column Operation Guidelines 11-2016 R.Cox Safety SAFETY GLASSES ARE REQUIRED WHEN OPERATING THE DISTILLATION COLUMN Wear gloves when mixing alcohol feedstock The column will become

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication

More information

Operating Instructions EB EN. Series 373x Electropneumatic Positioner Type 373x-5 EXPERT + with FOUNDATION fieldbus communication

Operating Instructions EB EN. Series 373x Electropneumatic Positioner Type 373x-5 EXPERT + with FOUNDATION fieldbus communication Series 373x Electropneumatic Positioner Type 373x-5 EXPERT + with FOUNDATION fieldbus communication Fig. 1 Valve diagnostics with TROVIS-VIEW Operator Interface Operating Instructions EB 8388-5 EN Firmware

More information

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications Application Description AG/266PILD-EN Rev. C 2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic Pressure Measurement Engineered solutions for all applications Increase plant productivity

More information

General instructions digital Mass Flow instrument CORI-FLOW

General instructions digital Mass Flow instrument CORI-FLOW Instruction manual General instructions digital Mass Flow instrument CORI-FLOW Doc. no.: 9.17.031J Date: 14-12-2015 ATTENTION Please read this instruction manual carefully before installing and operating

More information

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008 UNITY 2 TM Air Server Series 2 Operators Manual Version 1.0 February 2008 1. Introduction to the Air Server Accessory for UNITY 2...2 1.1. Summary of Operation...2 2. Developing a UNITY 2-Air Server method

More information

ECL Comfort 110, application 131 (valid as of software version 2.00)

ECL Comfort 110, application 131 (valid as of software version 2.00) Operating Guide ECL Comfort 110, application 131 (valid as of software version 2.00) English version www.danfoss.com How to navigate? Adjust temperatures and values. Switch between menu lines. Select /

More information

Mass Flow Meter (MFM) for gases

Mass Flow Meter (MFM) for gases Mass Flow Meter (MFM) for gases Type can be combined with Inline MFM for nominal flow rates from 25 l N /min to 1,500 l N /min; 1/4 to 3/4 High accuracy Fast settling time Fieldbus option Special version

More information

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation Page 1 of 19 : SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor Description and Principle of Operation The photoacoustic multi-gas monitor (INNOVA 1412, Innova AirTech Instruments, Denmark) is a highly

More information

Hydro-Control V User Guide

Hydro-Control V User Guide Hydro-Control V User Guide Hydronix Part no: HD0193 Version 2.3.0 Revision date: July 2006 1 COPYRIGHT Neither the whole or any part of the information contained in nor the product described in this documentation

More information

Instruction manual. MASS-VIEW series. Doc. nr.: F Date:

Instruction manual. MASS-VIEW series. Doc. nr.: F Date: Instruction manual MASS-VIEW series Doc. nr.: 9.17.051F Date: 22-12-2016 ATTENTION Please read this instruction manual carefully before installing and operating the instrument. Not following the guidelines

More information

IN-FLOW CTA Industrial Mass Flow Meters and Controllers for Gases

IN-FLOW CTA Industrial Mass Flow Meters and Controllers for Gases IN-FLOW CTA Industrial Mass Flow Meters and Controllers for Gases > Introduction Bronkhorst High-Tech B.V., the European market leader in thermal Mass Flow Meters/Controllers and Electronic Pressure Controllers,

More information

AX5000 Operational Manual

AX5000 Operational Manual MIYACHI AMERICA CORPORATION The World Leader in Hermetic Sealing Systems AX5000 Operational Manual 0 Document #107-00092-001 Dec, 2013 AX5000 Operational Manual Miyachi America Corporation 1820 S. Myrtle

More information

Instruction Manual. BZ7002 Calibration Software BE

Instruction Manual. BZ7002 Calibration Software BE Instruction Manual BZ7002 Calibration Software BE6034-12 Index _ Index Index... 2 Chapter 1 BZ7002 Calibration Software... 4 1. Introduction... 5 Chapter 2 Installation of the BZ7002... 6 2. Installation

More information

Injection Controller Program User Manual (for FloBoss 107 and ROC800-Series)

Injection Controller Program User Manual (for FloBoss 107 and ROC800-Series) Part D301757X012 June 2016 Injection Controller Program User Manual (for FloBoss 107 and ROC800-Series) Remote Automation Solutions Revision Tracking Sheet June 2016 This manual may be revised periodically

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability

More information

Overview. Front Panel: Keypad and Display

Overview. Front Panel: Keypad and Display Overview The GA-200B is an analyzer that integrates a gas sampling system with sensors to measure and display the concentrations of oxygen and carbon dioxide in a sample as the percentage of a gas in the

More information

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Cover Page for Lab Report Group Portion. Head Losses in Pipes Cover Page for Lab Report Group Portion Head Losses in Pipes Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 02 February 2012 Name 1: Name 2: Name 3: [Name 4: ] Date: Section

More information

The Discussion of this exercise covers the following points:

The Discussion of this exercise covers the following points: Exercise 5-3 Wet Reference Leg EXERCISE OBJECTIVE Learn to measure the level in a vessel using a wet reference leg. DISCUSSION OUTLINE The Discussion of this exercise covers the following points: Measuring

More information

Using Modbus Protocol with the ALTUS Net Oil Computer. Instruction Manual

Using Modbus Protocol with the ALTUS Net Oil Computer. Instruction Manual Using Modbus Protocol with the ALTUS Net Oil Computer Instruction Manual November 2000 Using Modbus Protocol with the ALTUS Net Oil Computer Instruction Manual November 2000 For technical assistance,

More information

Mini CORI-FLOW Compact Coriolis Mass Flow Meters/Controllers for Liquids and Gases

Mini CORI-FLOW Compact Coriolis Mass Flow Meters/Controllers for Liquids and Gases Instruction manual Mini CORI-FLOW Compact Coriolis Mass Flow Meters/Controllers for Liquids and Gases Doc nr.: 9.17.050H Date: 26-02-2013 ATTENTION Please read this instruction manual carefully before

More information

EXPERIMENT 1 AIR PRESSURE CONTROL SYSTEM

EXPERIMENT 1 AIR PRESSURE CONTROL SYSTEM EXPERIMENT 1 AIR PRESSURE CONTROL SYSTEM 1.0 OBJECTIVE To study the response of gas pressure control using PID controller. 2.0 INTRODUCTION TO THE APPARATUS a) The process plant consists of two air vessels

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Direct flow measurement with CMOSens technology for nominal flow rates from 0 ml N to 0 l N High accuracy and reproducibility Ingress protection IP Type can be combined

More information

RM-80 respiration monitor

RM-80 respiration monitor RM-80 respiration monitor User Manual September 18, 2015 0025-003M 950 North Hague Avenue Columbus, Ohio 43204-2121 USA Sales: sales@colinst.com Service: service@colinst.com Phone: (614) 276-0861 Fax:

More information

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION 1 INFORMATION and TECNICAL DESCRIPTION 14 2 AIRLEADER Professional Compressor Management + Compressed Air Visualisation + Alarm Service Management + AIRLEADER - has been the effective answer for compressed

More information

Experiment P18: Buoyant Force (Force Sensor)

Experiment P18: Buoyant Force (Force Sensor) PASCO scientific Physics Lab Manual: P18-1 Experiment P18: (Force Sensor) Concept Time SW Interface Macintosh file Windows file Newton's Laws 45 m 300/500/700 P18 P18_BUOY.SWS EQUIPMENT NEEDED CONSUMABLES

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The LDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

Application Notes. SLP85xD Load Cells

Application Notes. SLP85xD Load Cells Application Notes Load Cells Table of Contents 1 Introduction 3 2 Description of the Filling Cycle 4 3 Filling Optimization 7 4 Filling Monitor 8 4.1 Weight-Based Filling Monitor... 8 4.2 Time-Based Filling

More information

KIV-SACS Safe automatic calibration system:

KIV-SACS Safe automatic calibration system: KIV-SACS Safe automatic calibration system: LOK: g:\prosjekter\calibration_system\kiv safe calibration system.doc Page: 1 of 14 Parts description:... 4 Wash extractors:... 6 Tunnel washers:... 5 Test valve:...

More information

KEM Scientific, Inc. Instruments for Science from Scientists

KEM Scientific, Inc. Instruments for Science from Scientists KEM Scientific, Inc. Instruments for Science from Scientists J-KEM Scientific, Inc. 6970 Olive Blvd. St. Louis, MO 63130 (314) 863-5536 Fax (314) 863-6070 E-Mail: jkem911@jkem.com Precision Vacuum Controller,

More information

Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST)

Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST) Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST) Application Positioner firmware for early detection of control valve faults giving maintenance recommendations. Valid

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

Instruction manual. General instructions digital Mass Flow instrument LIQUI-FLOW L30. Doc. no.: E Date:

Instruction manual. General instructions digital Mass Flow instrument LIQUI-FLOW L30. Doc. no.: E Date: Instruction manual General instructions digital Mass Flow instrument LIQUI-FLOW L30 Doc. no.: 9.17.044E Date: 18-02-2014 ATTENTION Please read this instruction manual carefully before installing and operating

More information

Flow Vision I MX Gas Blending Station

Flow Vision I MX Gas Blending Station Flow Vision I MX Gas Blending Station Alicat Scientific, Inc. 7641 N Business Park Drive Tucson, Arizona 85743 USA alicat.com 1 Notice: Alicat Scientific, Inc. reserves the right to make any changes and

More information

Tutorial. BOSfluids. Relief valve

Tutorial. BOSfluids. Relief valve Tutorial Relief valve The Relief valve tutorial describes the theory and modeling process of a pressure relief valve or safety valve. It covers the algorithm BOSfluids uses to model the valve and a worked

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from ml N /min to 0 l N /min Applicable for aggressive gases Fieldbus option Type 870 can be combined with...

More information

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz GRUNDFOS DATA BOOKLET Complete pressure boosting systems 5/6 z Contents Product data Performance range 3 Operating conditions Inlet pressure Type key Product range 5 Construction 5 Installation 5 Mechanical

More information

SPIROVENT VACUUM DEGASSERS

SPIROVENT VACUUM DEGASSERS SPIROVENT VACUUM DEGASSERS S P I R O V E N T A I R S U P E R I O R FLUID AND GAS There are always a certain amount of gasses in a fluid, dependent on pressure and temperature. The British physicist William

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

HumiSys HF High Flow RH Generator

HumiSys HF High Flow RH Generator HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously

More information

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73 USER MANUAL Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * *) Require software ID: DID-SW-001 1/73 Table of contents 1 General... 3 1.1

More information

Built-in Purge Control Functions

Built-in Purge Control Functions Built-in Purge Control Functions Why clean a sensor? As the velocity sensor was calibrated clean, operating it clean also preserves the best calibration. Any build up of material on a thermal sensor tends

More information

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler. Exercise 5-2 Bubblers EXERCISE OBJECTIVE Learn to measure the level in a vessel using a bubbler. DISCUSSION OUTLINE The Discussion of this exercise covers the following points: Bubblers How to measure

More information

Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets

Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets Similar to the TC option for ST 3000 transmitters, the MC option for the SMV 3000 provides a service to our customers which results

More information

AMS 6915 Board mount pressure sensor with digital output (I²C)

AMS 6915 Board mount pressure sensor with digital output (I²C) Board mount pressure sensor with digital output (I²C) FEATURES Calibrated and temperature compensated pressure sensor with digital output (I²C) Differential, relative (gage), bidirectional differential,

More information

T EK-SUB 4800C 19 mm Submersible Level Transmitter

T EK-SUB 4800C 19 mm Submersible Level Transmitter Technology Solutions T EK-SUB 4800C 19 mm Submersible Level Transmitter Instruction Manual Document Number: IM-4800C www.tek-trol.com Table of Contents 1 Safety Instructions... 2 1.1 Intended Use... 2

More information

Model 130M Pneumatic Controller

Model 130M Pneumatic Controller Instruction MI 017-450 May 1978 Model 130M Pneumatic Controller Installation and Operation Manual Control Unit Controller Model 130M Controller is a pneumatic, shelf-mounted instrument with a separate

More information

REASONS FOR THE DEVELOPMENT

REASONS FOR THE DEVELOPMENT 7 Series 7 Series +24VDC VDC OUTPUT MICROPROCESS. E P IN EXH OUT 7 Series 7 ø,8 8 7 Series 9 5 8 9 7 Series Display features The proportional regulator has a 3 /2 digit display and a three-pushbutton

More information

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions Flow Meter with multiple functions for gases and liquids M3 The M-series Flow Meter, with its versatile and user-friendly

More information

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing) 1 X-Flow Mass Flow Controller Flow Range from 0.8 ml/min to 20 l/min Target Markets Laboratory and Process Instrumentation Pharma / Bio-Pharma Equipment Air Quality Monitoring Systems Furnace and Coatings

More information

GasSense NDIR User Manual

GasSense NDIR User Manual INDEX INDEX... 1 1. OVERVIEW... 2 2. TECHNICAL DATA... 3 3. SPECIFICATIONS... 4 4. PRODUCT DESCRIPTION... 5 4.1 Mechanical details... 5 4.2 Piping... 7 4.3 Connections... 7 5. INSTALLATION... 10 6. CALIBRATION

More information

Special Documentation Proline Promass 300 Modbus RS485. Petroleum Application Package MANUAL

Special Documentation Proline Promass 300 Modbus RS485. Petroleum Application Package MANUAL MANUAL Special Documentation Proline Promass 300 Modbus RS485 Petroleum Application Package SD02131O/06/EN/02.18 Valid as of version 01.02.zz (Device firmware) 71425783 Important All information and technical

More information

Coriolis Mass Flow Meter

Coriolis Mass Flow Meter Coriolis Mass Flow Meter TMFW Series Mini Type Coriolis Mass Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com;

More information

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司 X-Flow Mass Flow Controller 2 Highlights Parker Hannifin Precision Fluidics Division is excited to introduce X-Flow, a new easy to use general purpose mass flow controller for your instrument, lab, or

More information

Cover Page for Lab Report Group Portion. Pump Performance

Cover Page for Lab Report Group Portion. Pump Performance Cover Page for Lab Report Group Portion Pump Performance Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 02 March 2012 Name 1: Name 2: Name 3: [Name 4: ] Date: Section number:

More information

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

MCQ Gas Blender 100 Series 3 Channels Gas Mixer Channels Gas Mixer Revision 1.8 October 2016 High Performance Digital Gas flow Gas Dilutor Blender & Gas for Mixing flow Mixing Gases System and Calibration Routines Technical Data Sheet Lab in a box From

More information

T EK-COR 1100A Coriolis Mass Flowmeter

T EK-COR 1100A Coriolis Mass Flowmeter T EK-COR 1100A Coriolis Mass Flowmeter Instruction Manual Document Number: IM-1100A NOTICE Read this manual before working with the product. For personal and system safety, and for optimum product performance,

More information

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments Pegas 4000 MF Gas Mixer InstructionManual Contents I Table of Contents Foreword Part I Introduction 1 2 1 System overview... 2 2 Specifications... 3 Part II Installation 4 1 Rear panel connections...

More information

Design Envelope Booster. Sequence of operation

Design Envelope Booster. Sequence of operation Design Envelope Booster Sequence of operation File No: 62.835 Date: february 11, 2015 Supersedes: 62.835 Date: july 11, 2014 sequence of operation Design Envelope Booster 2 general The packaged domestic

More information

SAUTER flexotron 800 heating. List of network variables for Modbus communication. Manual P A P

SAUTER flexotron 800 heating. List of network variables for Modbus communication. Manual P A P SAUTER flexotron 800 heating List of network variables for communication Manual P100013118 A P100012094 2/90 P100013118 A Content Content 1 General notes 5 1.1 Disclaimer 5 1.2 Trademarks 5 2 Preface 7

More information

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Specifications and information are subject to change without notice. Up-to-date address information is available on our website. www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available on our website. web: www.smar.com/contactus.asp FY302 AssetView IHM FY302 -

More information

Precision level sensing with low-pressure module MS

Precision level sensing with low-pressure module MS The task on hand Level sensing as it is understood in modern process automation is much more than simply "tank half full" or "tank a quarter full". Using suitable sensors, levels, inlets and outlets can

More information

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers MASS-STREAM TM Instruction Manual D-6200 Analog Mass Flow Meters / Controllers Doc. No.: 9.17.112A Date: 17-03-2017 ATTENTION Before installing and operating the instrument it is strongly recommended that

More information

1.2 Example 1: A simple hydraulic system

1.2 Example 1: A simple hydraulic system Note: It is possible to use more than one fluid in the Hydraulic library. This is important because you can model combined cooling and lubrication systems of a library. The hydraulic library assumes a

More information

A4s Operation Manual

A4s Operation Manual A4s Operation Manual Safety Instruction Please read this manual carefully, also with related manual for the machinery before use the controller. For installing and operating the controller properly and

More information

Instruction Manual Dräger MSI P7 and MSI P7 plus

Instruction Manual Dräger MSI P7 and MSI P7 plus Dräger MSI GmbH Rohrstraße 32 58093 Hagen Tel.: +49-2331 / 9584-0 Fax: +49-2331 / 9584-29 e-mail: info@draeger-msi.de D 923; Edition 2011-01-01 Content 1. General Hints Page 4 2. The Instrument 2.1 Front

More information

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER Features ±0.01% FS Measurement & Control Accuracy ±0.001% /ºC Thermal Stability Pressure Ranges from ±1 psid to 1200 psia Applications Barometric Measurement

More information

陕西创威科技有限公司. Shaanxi Creat Wit Technology Co., Ltd. Precision pressure calibrator-cwy300 Operating Manual

陕西创威科技有限公司. Shaanxi Creat Wit Technology Co., Ltd. Precision pressure calibrator-cwy300 Operating Manual Precision pressure calibrator-cwy300 Operating Manual 陕西创威科技有限公司 Shaanxi Creat Wit Technology Co., Ltd Tel: +86 029 86690023 Fax: +86 029 86690023 Mob: +86 18202956927 Email: sales@creatwit.com Content

More information

Gerald D. Anderson. Education Technical Specialist

Gerald D. Anderson. Education Technical Specialist Gerald D. Anderson Education Technical Specialist The factors which influence selection of equipment for a liquid level control loop interact significantly. Analyses of these factors and their interactions

More information

Digital Level Control One and Two Loops Proportional and Integral Control Single-Loop and Cascade Control

Digital Level Control One and Two Loops Proportional and Integral Control Single-Loop and Cascade Control Digital Level Control One and Two Loops Proportional and Integral Control Single-Loop and Cascade Control Introduction This experiment offers a look into the broad field of process control. This area of

More information

The Discussion of this exercise covers the following points:

The Discussion of this exercise covers the following points: Exercise 3-2 Orifice Plates EXERCISE OBJECTIVE In this exercise, you will study how differential pressure flowmeters operate. You will describe the relationship between the flow rate and the pressure drop

More information

The intelligent alternative for VA meters: mass flow meters for gases with flow display

The intelligent alternative for VA meters: mass flow meters for gases with flow display The intelligent alternative for VA meters: mass flow meters for gases with flow display > Introduction Bronkhorst, specialists in low flow measurement and control, have designed an innovative series of

More information

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

T EK-COR 1100A. Coriolis Mass Flowmeter.   FLOW. Technology Solutions Technology Solutions T EK-COR 1100A Coriolis Mass Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction There can often be more than one type

More information

EZ Boom 2010 System for the EZ Guide 500 Lightbar Triangle Ag Services Users Guide

EZ Boom 2010 System for the EZ Guide 500 Lightbar Triangle Ag Services Users Guide EZ Boom 2010 System for the EZ Guide 500 Lightbar Triangle Ag Services Users Guide Parts of the Controller (For details on the parts of the EZ Boom controller refer to Appendix F) Status Indicator Rate

More information

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc. The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is

More information

Bypass Mass Flow Controller (MFC) for gases

Bypass Mass Flow Controller (MFC) for gases Bypass Mass Flow Controller (MFC) for gases Bypass MFC with Capillary technology for nominal flow rates from ml N /min to l N /min Suitable for aggressive gases Fieldbus option Type 870 can be combined

More information

Exercise 3. Power Versus Wind Speed EXERCISE OBJECTIVE DISCUSSION OUTLINE. Air density DISCUSSION

Exercise 3. Power Versus Wind Speed EXERCISE OBJECTIVE DISCUSSION OUTLINE. Air density DISCUSSION Exercise 3 Power Versus Wind Speed EXERCISE OBJECTIVE When you have completed this exercise, you will know how to calculate the power contained in the wind, and how wind power varies with wind speed. You

More information

PRODUCT OVERVIEW. Gas mixers Test bench systems Leak test and impermeability testing systems High pressure dosing pumps

PRODUCT OVERVIEW. Gas mixers Test bench systems Leak test and impermeability testing systems High pressure dosing pumps PRODUCT OVERVIEW Gas mixers Test bench systems Leak test and impermeability testing systems High pressure dosing pumps COMPLETE SOLUTIONS FLUSYS is solely dedicated to producing solutions for projects

More information

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM M+W Instruments Your partner Key Facts M+W Instruments was founded in 1988 and has always specialised in thermal mass flow meters

More information

Unit 55: Instrumentation and Control Principles

Unit 55: Instrumentation and Control Principles Unit 55: Instrumentation and Control Principles Unit code: J/601/1417 QCF level: 4 Credit value: 15 OUTCOME 2 PROCESS CONTROL SYSTEMS AND CONTROLLERS 2 Understand process control systems and controllers

More information

Instruction Manual. Doc. no.: A Date:

Instruction Manual. Doc. no.: A Date: Instruction Manual Controlled Evaporator and Mixer (CEM) Doc. no.: 9.17.126A Date: 02-10-2018 ATTENTION Please read this Instruction Manual carefully before installing and operating the instrument. Not

More information

C-Flow Coriolis Mass Flow Meters

C-Flow Coriolis Mass Flow Meters Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM

More information

Figure SM1: Front panel of the multipatcher software graphic user interface (GUI) at the beginning of multipatcher operation.

Figure SM1: Front panel of the multipatcher software graphic user interface (GUI) at the beginning of multipatcher operation. APPENDIX 2. Multipatcher Software Setup and Operation. The multipatcher program is organized into four panels. There are controls that allow the user to specify various parameters into the system. The

More information

Manual Weighingblock VB2 series and Uniscale

Manual Weighingblock VB2 series and Uniscale Manual Weighingblock VB2 series and Uniscale Note: At page 8 in this manual you will find a short form instruction. Normally the only instruction shipped together with the Scale. Overview different ranges.

More information

FOOD INTAKE MONITOR. Hardware and Software User s Manual DOC-047 Rev 3.0. Copyright 2009 All Rights Reserved

FOOD INTAKE MONITOR. Hardware and Software User s Manual DOC-047 Rev 3.0. Copyright 2009 All Rights Reserved Hardware and Software User s Manual DOC-047 Rev 3.0 Copyright 2009 All Rights Reserved MED Associates, Inc. P.O. Box 319 St. Albans, Vermont 05478 www.med-associates.com - ii - TABLE OF CONTENTS Chapter

More information

S-CURVE DOCUMENTATION AND TUTORIAL FOR THE S-CURVE ON THE COOL MUSCLE

S-CURVE DOCUMENTATION AND TUTORIAL FOR THE S-CURVE ON THE COOL MUSCLE S-CURVE DOCUMENTATION AND TUTORIAL FOR THE S-CURVE ON THE COOL MUSCLE 1. INTRODUCTION The s-curve function allows the user to define a smooth response yet still maintain a high acceleration. In many applications

More information

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Universal pycnometer, no

More information

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values Operations Manual Please read, understand, and follow these instructions before operating this equipment.

More information