IN-SITU ZIRCONIA OXYGEN ANALYZER < ZIRCOMAT-C >
|
|
- Todd Smith
- 5 years ago
- Views:
Transcription
1 IN-SITU ZIRCONIA OXYGEN ANALYZER < ZIRCOMAT-C > DATA SHEET ZFK, ZRY This oxygen analyzer is used to continuously measure oxygen concentration in combustion exhaust gas of industrial boilers or furnaces, and is ideally suited for combustion monitoring and control. The detector (ZFK) used with the analyzer is directly inserted into the objects measured, eliminating the need for a sampling device and provides quick response. The converter (ZRY) features 3 measuring ranges, one touch calibration and NEMA4 housing. Comparing to the current converter (ZRM), this ZRY is recognized as economical type with simple functions. General-use detector FEATURES. Sampling device is unnecessary Gas sampling devices such as a gas aspirator, a dehumidifier, etc. are unnecessary because of use of directinsertion type detector.. High speed response The adoption of a flow guide tube utilizing the flow of the measured gas assures quick response (less than 7sec). 3. Dust-tight and water-proof housing Aluminum die casting housing of converter satisfies NEMA4 and IP6 standard measuring ranges and one touch calibration The converter has 0-, 0, vol% 3 ranges easily changed by pin connection and zero and span are simply calibrated by key operation. SPECIFICATIONS General Measuring object: Oxygen contained in noncombustible gas Measuring principle: Direct-insertion zirconia system Measuring range: 0 to, 0 or vol% O (Changed by internal set pin) Repeatability: Within ±.0% of full scale Linearity: ±% of full scale Response time: Within 7sec for 90% response (from calibration gas inlet) Power supply: 00,, 0 or 30V AC, 0/60Hz Power consumption: (approx.) + 0VA (at steady state) + 00VA (at start) Warmup time: Approx. min Converter Oxygen detector (ZFK, ) Measuring detector: For general-use: ZFK For corrosive gas: ZFK Measured gas temperature: system; 0 to +600 C Measured gas pressure: 3 to +3kPa : Flange; JISK 6A FF (JISK-80AFF for high particulate gas) Insertion length; 0.3, 0., 0.7, m (0.8m for high particulate gas) Ambient temperature: 0 to +60 C for cable section C or less at detector flange surface with power applied Structure: Dust/rain-proof structure(iec IP equivalent) Filter: Alumina(filtering accuracy 0μm) and quartz paper Main materials of gas-contacting parts: General-use detector(zfk ); Zirconia, SUS36, platinum, SUS304 Anticorrosive detector(zfk ); Zirconia, tita-nium, platinum, SUS36 ; SUS304 or SUS36 EDSX3-9a Date Sep.0,999
2 ZFK, ZRY Calibration gas inlet: Brass joint for φ/4 inch tube. Reference air inlet (option): Rc/8 or NPT/8 Detector mounting: Horizontal plane ± 4, ambient surrounding air should be clean. Outer dimensions: (L x max. dia.) 0mm x 00mm (detector) Mass (approx.) {weight}: Detector;.6kg (general-use, m); kg Finish color: Silver and SUS metallic color Oxygen converter (ZRY) Measuring range: 0-, 0, vol% O Changeable by internal set pin. Repeatability: ±.0% of full scale Lineality: ±.0% of full scale Indication: Oxygen concentration; 3-digit LED Oxygen concentration output signal: 4 to 0mA DC (allowable load resistance: 00 Ω or less) Isolated output, linear Fault contact output: 0V AC, A rating (close contact or open contact for fault should be specified when you place an order.) Self-diagnoses: Fault of sensor temperature, zero calibration error, span calibration error Calibration method: Manual calibration with key operation Calibration gas: Recommended calibration gas concentration Zero gas;.0 to.0% O Span gas; 0.6 to.0% O (oxygen concentration in the air) Ambient temperature: 0 to +0 C Ambient humidity: 90% RH or less Power supply: 90 to 0 or 30 V AC, 0/60Hz Construction: Dust-tight, waterproof construction, NEMA4 (corresponding to IP6 of IEC) Material: Aluminum die casting Outer dimensions (H x W x D): 0 X 30 X 9mm Mass {weight}: Approx. 4.kg (excluding cable and detector) Finish color: Munsell 6PB 3./0. (blue): cover, silver; case Mounting method: Mounted flush on panel Exclusine cable (ZRZP) Cable: 4-cores sealed wire (O signal and R- themo couple signal) and -cores cable (power) Cable conduit: Flexible type Length: Refer to code symbols SCOPE OF DELIVERY Detector: Detector main unit x, Viton O ring x, mounting screw (Mmm x ) x 6, thermal sticker x, flow guide tube (as specified) x, ceramic filter x, cover (as specified) x, reference air inlet (as specified) x Converter: Converter main unit x Accessories (AC0V 00mA T fuse x, AC0V 3.A T fuse x ) Items to be prepared separately: () Standard gas for calibration Type ZBM NSK4-0 () Reduction valve for standard gas (type ZBD6003) (3) Flowmeter Type; ZBD03, 0. to L/min (for calibrating gas) CAUTIONS If combustible gas (CO, H etc.) exists in the measured gas, error will occur due to burning at the sensor section. The inclusion of corrosive gas (Si vapor, alkaline metal, P, Pb etc.) will shorten the life of the sensor. When the measured gas temperature is high (+300 C or higher), the flange should be separated from the furnace wall in order to bring the detector flange surface temperature below the specified value + C). The flow guide should be attached in the direction in which the gas flow to the detector decreases. When dust more than g/nm 3 is included in the gas, manual blow down is necessary. The product conforms to the requirements of the Electromagnetic compatibility Directive 89/336/EEC as detailed within the technical construction file number TZ The applicable standards used to demonstrate compliance are : EN 0 : 99 CLASSA Conducted and Radiated emissions EN 008- : 99 Radiated immunity, ESD and FBT ZFK, ZRY
3 DEVICE CONFIGURATION The device to be combined differ according to the conditions of the gas to be measured. Please select the devices to be combined with reference to the following table. Measured gas Device configuration Application Temperature Gas Flow DUST Protection cover Note Detector type Converter type Ejector type General-use 600 C or (boiler) less Anti-corrosive use (incinerator) to 0m/s Less than 0.g/m 3 [nor] Less than 0g/m 3 [nor] no Less than g/m 3 [nor] yes Fuel; gas, oil Fuel: coal with manual blow down Included high moisture with manual blow down ZFK R 4- ZFK R 4-6 D 8 ZFK R 4-6 E 8 ZRY ZRY ZRY Note () Dust volume is approximate value. () Instrument quality air or bottled air is available as reference air by selecting detector with reference air inlet, when oxygen concentration in air around sensor changes. CODE SYMBOLS (Detector) ZFK R Y 0 A 3 A A 7 A B 3 B B 7 B 6 D 8 6 E 8 Y A Y A B Cal. gas inlet For φ/4 inch tube ( Replacement Detector element) ZFK R Description Application General use. For corrosive gas (refuse incinerator) Power supply 00/VAC 0/60Hz 00/0VAC 0/60Hz 30VAC 0/60Hz (CE-marking approved) flange application length SUS304 general use 300mm SUS304 general use 00mm SUS304 general use 70mm SUS304 general use 000mm SUS36 for corrosive gas 300mm SUS36 for corrosive gas 00mm SUS36 for corrosive gas 70mm SUS36 for corrosive gas 000mm SUS36 for high particulate 800mm SUS36 for high particulate with 800mm cover Protection cover Without With Reference air inlet Non Rc/8 NPT/8 Description Application General use. For corrosive gas (refuse in cinerator) Cal. gas inlet For φ/4 inch tube Power supply 00/VAC 0/60Hz 00/0VAC 0/60Hz 30VAC 0/60Hz (Converter) Z R Y Y - R 0 B C (Exclusive-special cable) Z R Z PR P R YA YB YC YD YE YF YG YH YJ YK YL YM AA BB CC DD Y E Description Connectable devices For ZRY Types For R thermocouple Conduit length Cable length 6m 0m m 0m 30m 40m 0m 60m 70m 80m 90m 00m 6m 6m 0m 0m m m 0m 0m Cable end treatment One side (detector side) Both sides Note: Description Output signal and fault output 4 to 0mA DC, close contact 4 to 0mA DC, open contact Power supply 90 to 30V AC 0/60Hz (CE marking approved) Mounting method Panel mounting Instruction manual NO YES (English) For connection between detector and converter, the conduit to be used should be rainproof flexible type. 3
4 ZFK, ZRY CONFIGURATION system Cover for retaining warmth Status of fault contact output Detector ZFK digit of model Power off Power on and normal Power on and fault B open open close Gas temperature. 600 C max. C open close open Sample gas outlet *3 Ball valve Bule Black Red Yellow White White Rainproof flexible conduit. 0m max. Gas temperature. 600 C max. -core cable 4-core cable Thermocouple signal Zirconia signal Converter (ZRY) Analog output Fault contact output Sensor heater for high particulate 6mm or 4 inch tube for calibration gas (not supplied) *3 Ball valve Red White Blue Yellow Cell/thermocouple output Heater power supply DC4 to 0mA Black White AC power supply Sample gas outlet Gas temperature. 600 C max. Flow guide for high particulate with cover Change valve Reduction valve (ZBD6) to Detector * Ref. air Flowmeter (ZBD4) ( to.l/min) Standrad gas for zero point (ZBM) Reduction valve (unnecessary when supply air pressure is 0 to 00kPa * Air supply (0. to 0.L/min) Reduction vale (ZBD6) * Standard gas for span point (ZBM) Note * Sandard gas or instrumentation air can be used in place of span gas. * Instrument quality air or bottled air is available as reference air instead of ambient air, when oxygen concentration in air around sensor changes. *3 Blow down air inlet pressure in 00 to 300kpa. 4
5 60 OUTLINE DIAGRAM (Unit:mm) Detector (ZFK) Proof cover (to order) Approx. 30 Approx. 6 Approx Filter EXTERNAL CONNECTION DIAGRAM 8 Heater Thermocouple Element output A Approx. Ref. air inlet (to order) NPT/8 or Rc/ Black / White/ Red / White/ Yellow / Blue -core wire 4-core wire Exclusive-special cable Exclusive cable gland Calibration gas inlet for /4 inch tube. Approx. L Approx Gas inlet 0 34 Z F K R 4 - A 3 7 Gas outlet 6-M detector side Oxygen detector Cord th L (m) MASS Approx (kg) Z L= (to order) 8 MTG. holes
6 ZFK, ZRY Detector (ZFK) Proof cover (to order) Approx. 30 Approx. 6 Approx Filter EXTERNAL CONNECTION DIAGRAM 8 Heater Thermocouple Element output 60 Approx. 3 Ref. air inlet (to order) NPT/8 or Rc/ Black / White/ Red / White/ Yellow / Blue -core wire 4-core wire Exclusive-special cable Exclusive cable gland Calibration gas inlet for /4 inch tube. 3 Approx. L Approx Gas inlet 60. Z F K R 4 - B 3 7 Gas outlet 6-M detctor side Oxygen detector Cord th L (m) MASS Approx (kg) Z L= (to order) 8- MTG. holes 6
7 (for high particulate) 4 - Rc /4 with plug int thd Blow down air inlet 8-9 MTG. hole Select an upper port to avoid the condensation in the piping 9. Flange: JIS K80A FF ZFK MTG. position Packing 8 Z F K R 4-6 D8 0 Gas outlet Gas flow Tube (0A SCH40) (for high particulate with cover) 4 - Rc /4 with plug int thd MTG. holes Blow down air inlet Select an upper port to avoid the condensation in the piping 9. Flange: JIS K80A FF ZFK MTG. position Packing (7) 0 Z F K R 4-6 E8 Gas outlet (790) Gas flow Protection tube (6A SCH40) (38) Tube (0A SCH40) 7
8 ZFK, ZRY Converter (ZRY) Panel flush mounted -φ CABLE GRAND φ 39 -G/ CONNECTION DIAGRAM L N THERMO- COUPLE ELEMENT INPUT OUTPUT SIGNAL FAULT CONTACT OUTPUT HEATER POWER FOR SENSOR POWER SUPPLY Fuji Electric Your distributor: Coulton Instrumentation Ltd 7 Somerford Business Park, Christchurch, BH3 3RU, UK Tel: sales@coulton.com Web: Information in this catalog is subject to change without notice. Printed in Japan
ZIRCONIA OXYGEN ANALYZER CONVERTER
Instruction Manual ZIRCONIA OXYGEN ANALYZER CONVERTER TYPE: ZRY OXYGEN ANALYZER Vol% O2 PREFACE We are grateful for your purchase of Fuji Zirconia Oxygen Analyzer Converter (ZRY). First read this instruction
More informationIntegral type Differential pressure flowmeter VNT Series
Integral type Differential pressure flowmeter VNT Series OUTLINE VH series Wafer-Cone differential pressure flowmeter and high precision differential pressure transmitter are integrated into one flowmeter.
More informationZIRCONIA OXYGEN ANALYZER CONVERTER
Instruction Manual ZIRCONIA OXYGEN ANALYZER CONVERTER Type: ZKM INZ-TN1ZKMf-E PREFACE We are grateful for your purchase of Fuji Direct Insertion Type Zirconia Oxygen Analyzer Converter (ZKM). First read
More informationTwo-Wire In Situ Oxygen Analyzer (550 to 1400 C)
Product Data Sheet PDS 106-581.A01 March, 2004 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: - CENELEC EEx ia IIC - Class I Div. I Gr. B, C, D (pending) Operates at
More informationZIRCONIA OXYGEN ANALYZER CONVERTER
Instruction Manual ZIRCONIA OXYGEN ANALYZER CONVERTER (SINGLE-CHANNEL TYPE) TYPE: ZRM Fuji Electric Co.,Ltd. INZ-TN1ZRMa-E PREFACE We are grateful for your purchase of Fuji Electric s Zirconia Oxygen Analyzer
More informationTH-1800-T TRX-700-CNG Converter
TH-1800-T TRX-700-CNG Converter low detector The CNG fuel gas flowmeter is so accurate as to meet a demand of measuring the CNG directly by making the most use of our well-established mini-thermal flowmeter
More informationDesign Features. General Description
Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design
More informationcombustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company
combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring An Company Flue Gas Oxygen Genesis is a range of flue gas analyzers for measuring
More informationTwo-Wire In Situ Oxygen Analyzer (550 to 1400 C)
Product Data Sheet PDS 106-581.A01 September, 2007 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: ATEX, Zone 1, EEx ia IIC T4 Class I, Div. I, Gr. A, B, C, D T4 Operates
More informationModel EXAxt AV550G. Averaging Oxygen Analyzer
Model EXAxt AV550G Averaging Oxygen Analyzer Oxygen Measurement and Flyash Oxygen % vs cell EMF The O2 mation, model AV550, averaging oxygen analyzer was designed with a focus Calibration 1 on practical
More informationColumbus Instruments
0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011
More informationcombustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring
combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring Flue Gas Oxygen Genesis is a range of flue gas analyzers for measuring Oxygen
More informationModel ZX8D Zirconia Oxygen Analyzer
User s Manual Model ZX8D Zirconia Oxygen Analyzer IM 11G00E01-01EN IM 11G00E01-01EN 6th Edition u Introduction Thank you for purchasing the ZX8D Zirconia Oxygen Analyzer. Please read the following respective
More informationAutocalibration Systems For In Situ Oxygen Analyzers
Product Data Sheet PDS 106-340AC SPS 4000, IMPS 4000, and MPS 3000 January, 1999 Autocalibration Systems For In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging from
More informationSM425 ZIRCONIA OXYGEN ANALYZER
INSTRUCTION MANUAL SM425 ZIRCONIA OXYGEN ANALYZER 35 INVERNESS DRIVE EAST ENGLEWOOD, CO 80112 USA TOLL-FREE SUPPORT: 800-846-6062 FAX: 303-799-4853 TEL: 303-792-3300 E-MAIL: tml_support@teledyne.com WEBSITE:
More informationE8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)
Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationOXYGEN MONITORING SYSTEM OMS
User Manual OXYGEN MONITORING SYSTEM OMS 420 Read and observe before commissioning! Ex Situ oxygen analyzer based on ZrO 2 sensor ENGLISH Caution! Please inspect in the presence of the transporting agent
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication
More informationTechnical Data Sheet MF010-O-LC
Technical Data Sheet MF010-O-LC - 1 - 1. Properties The oxygen measuring system MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 C. It is particularly suitable for the
More informationBest Practice Guide, Servomex 2700
For full installations details refer to the. Best Practice Guide, Servomex 2700 Mounting: General Guidelines: Servomex 2700 Control Units and air supplies (utilities units) should, ideally, be mounted
More informationAuto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance
More informationDMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.
Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More informationZIRCONIA OXYGEN DETECTOR SERVICE MANUAL
Service Manual ZIRCONIA OXYGEN DETECTOR SERVICE MANUAL TYPE: ZFK 3, 4, 7 TN5A08a-E CONTENTS. PREFACE.... MEASUREMENT PRINCIPLE... 3. ADJUSTMENT...3 3. Zero (Air) Adjustment... 3 3. Span Adjustment... 3
More informationMass Flow Meter (MFM) for Gases
873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital
More informationKTE6000 / KTU6000 Series OEM pressure transmitters for industrial media
FEATURES 50 mbar to 400 bar, 5 to 6000 psi gage or absolute pressure For many industrial gases and liquids 00, 0545, 05, 6 or 40 ma output Field interchangeable EMC according to EN 66-8 MEDIA COMPATIBILITY
More informationanalytical bulk flow distance FLOW level pressure temperature industrial communication
analytical bulk flow distance level pressure temperature industrial communication isolv THERMAL MASS METER Measuring Principle Self-heated Sensor Reference Sensor isolv Thermal Mass Flow Meters have two
More informationALL-IN-ONE MINI THERMAL MASS FLOWMETER
INDICATION, TOTAIZATION, -POINT AARM, DC to ma AND PUSE OUTPUT BY ONE UNIT TF-T Series A-IN-ONE MINI TERMA MASS FOWMETER OUTINE TF-T MINI TERMA MASS FOWMETER is for the measurement of mass flow rate of
More informationDF-310E PROCESS ANALYSERS APPLICATIONS FEATURES
PROCESS ANALYSERS DF-310E The DF-310E is a Coulometric sensor based oxygen analyzer designed to measure trace and percent level oxygen in pure and multi-gas backgrounds for process and quality control
More informationTapped exhaust port. Sturdy, simple, reliable design. Easy to add on Feedback. High gain pilot valve. Simple calibration, external zero adjustment
Electropneumatic Positioner Sturdy, simple, reliable design High gain pilot valve Built in gauge ports Tapped exhaust port Easy to add on Feedback Unit F5 Simple calibration, external zero adjustment Bright
More informationMass Flowmeters. Mass Flowmeters for Gases
Mass Flowmeters Mass Flowmeters for Gases Fast, Accurate, Low Pressure Drop for critical measurement applications! Flow (Std l/min) Response to a step change in flowrate 300 200 100 4 Milliseconds 63%
More informationUNDERSTANDING, ACCELERATED
UNDERSTANDING, ACCELERATED MEASURE FLOW, PRESSURE, AND TEMPERATURE ALL IN ONE INSTRUMENT! Designed for Performance TSI thermal mass flowmeters incorporate a proprietary platinum film sensor design for
More informationLevel transmitter LT 100
KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters
More informationALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential
More informationGas density monitor With integrated transmitter Model GDM-100-TI
SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed
More informationOperating Instructions Part No
DIGITAL AUTOMATIC TYRE INFLATOR Operating Instructions Part No. 11.0545 Thank you for selecting this Jamec Pem Automatic Tyre Inflator. Please read this manual before carrying out any installation or service
More information2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure
Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationGFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features
Design Features Rigid metallic construction. Maximum pressure of 1000 psig (70 bars). Leak integrity 1 x 10-7 of helium. NIST traceable certification. Built-in tiltable LCD readout. 0-5 Vdc and 4-20 ma
More informationPlasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling
SERVOPRO Plasma The SERVOPRO Plasma is a Plasma Emission Detector based analyser designed to continuously measure Nitrogen in pure Argon for process and quality control in Argon production within Cryogenic
More informationZirconia Oxygen Analyzer Systems
Data Sheet Zirconia Oxygen Analyzer Systems ZMT & ZGP/EXGP Series Integral reference air supply option avoids necessity for additional equipment Dual-fuel data input with manual or automatic selection
More informationFeatures. Description
Features Fast response flow meter ideal for inert gas and liquid mass flow measurement applications Smart electronics permit field adjustment of critical flow meter settings Field validation of flow meter
More informationCONTENTS OVERVIEWS PRODUCT INFORMATION
FUJI ELECTRIC CATALOGUE 2017 CONTENTS OVERVIEWS About Us 3 Fuji Electrical Gas Analysis 4 Support for Fuji Electric Gas Analysis Products 4 Emissions Monitoring - CEMS 5 Conversion Factors 6 PRODUCT INFORMATION
More informationFlow and Energy Measurement F-5400 THERMAL MASS FLOW METER
THERMAL MASS FLOW METER s Series Thermal Mass Flow Meters provide accurate and reliable flow measurement for natural gas, compressed air, and other industrial gas applications. Natural Gas Compressed Air
More informationGeneral Specifications
EXA ZR402G General Specifications Model ZR22G, ZR402G, and ZR202G Direct In Situ Zirconia Oxygen Analyzers and High Temperature Humidity Analyzers Overview This analyzer consists
More informationSpecifications of Oxygen Sensor Module V-8344A
Specifications of Oxygen Sensor Module V-8344A 1. General: This document describes about the specification of Ceramic Oxygen Sensor module, FUJIKURA's FCX-MWL-F-(AC). Table shown below is revision records
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer
ABB MEASUREMENT & ANALYTICS DATA SHEET Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer 2 E N D U R A AZ 40 OX YG EN AN D CARBON MONOXIDE E QU IVALE NT (COE ) ANALY ZE R DS/AZ40-E N RE
More informationMiniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800
KROHNE 1/22 7.236.22. GR Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 8 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters
More informationFLAMMABLE GAS SENSOR/TRANSMITTER
FLAMMABLE GAS SENSOR/TRANSMITTER Plant safety protection for flammable gases. F E A T U R E S Fixed gas monitoring for point source hazards and perimeter protection in arduous duty and exposed locations.
More informationMASFLO-OVAL Ⅱ THERMAL MASS FLOWMETER/CONTROL VALVE for GAS MEASUREMENT MODEL: FHC, FHD series
Gas EXPLOSIONPROOF MASFLO-OVAL Ⅱ THERMAL MASS FLOWMETER/CONTROL VALVE for GAS MEASUREMENT MODEL: FHC, FHD series GENERAL SPECIFICATION GS.No.GBF112E 1 GENERAL The explosionproof MASFLO-OVAL Ⅱ FHC series
More informationGeneral Specifications
EXA ZR402G General Specifications Model ZR22G, ZR402G, and ZR202G Direct In Situ Zirconia Oxygen Analyzers and High Temperature Humidity Analyzers Overview This analyzer consists
More informationbetter measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis
More informationIN-SITU ZIRCONIA OXYGEN ANALYZER FOR HAZARDOUS LOCATION ZFKE, ZKME
DATA SHEET I-SITU ZIROIA OXYGE AALYZER FOR HAZARDOUS LOATIO ZFKE, ZKME This oxygen analyzer is used to continuously measure oxygen concentration in noncombustible exhaust gas of industrial boilers furnaces,
More informationINSTALLATION & MAINTENANCE INSTRUCTIONS
DESCRIPTION / IDENTIFICATION The QBX series valve uses Proportion-Air closed loop technology for Pressure control. It gives an output pressure proportional to an electrical command signal input. The QB1X
More informationElectro-Pneumatic Converter YT-940 SERIES
Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product
More informationSupplementary Operator s Manual 42/24-14 EN Rev. 3
Advance Optima Continuous Gas Analyzers AO2000 Series with Uras26, Magnos206, Caldos25, Caldos27 Designed per Category 3G for Measurement of Flammable Gases ( Safety Concept ) and Non-flammable Gases Supplementary
More informationINFRARED GAS ANALYZER
INFRARED GAS ANALYZER DATA SHEET ZPA This gas (ZPA) is capable of measuring the concentration of NO,SO,CO,CO,CH and O components in sample gas. NO, SO, CO, CO and CH are measured by non-dispersion infrared
More informationType N-10, N-11 Hazardous Area Non-incendive Transmitters
Electronic Pressure Catalog > Hazardous Area > N-10, N-11 Type N-10, N-11 Hazardous Area Non-incendive Transmitters Applications Natural gas compressors Wellhead monitoring Pipeline pressure General industrial
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability
More informationSimple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18
The Bray Simple Set Max is a flanged pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SSM Series combines high rangeability
More informationMass Flow Controllers
Mass Flow Meters & Controllers HFM-D-3A & 305A Mass Flow Meters HFC-D-3A & 307A Mass Flow Controllers FEATURES Range 0-25 slm to 0-2500 slm (N 2 Equivalent) Excellent Accuracy ±(0.5% of Reading + 0.2%
More informationClimatic Independent Level Sensor LAR
1 Product Information LAR-361 LAR-761 Climatic Independent Level Sensor LAR Application / Specified usage Authorizations Hydrostatic level measurement in humid ambiance Special applicable for exterior
More informationProgrammable pressure and temperature transmitters PTM/RS485
Programmable pressure and temperature transmitters PTM/RS485 Version: 03-28-2012 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x
More informationC-Flow Coriolis Mass Flow Meters
Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM
More informationHot extractive multi-channel gas analyser for continuous process and emissions monitoring.
Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions
More informationPicture. Minimum cable bending radius 100 mm [4"] < 400 N [90 lbf] (PE / PUR cables) < 15 N [3.4 lbf] (FEP cables)
Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring
More informationDF-550E PROCESS ANALYSERS APPLICATIONS FEATURES
PROCESS ANALYSERS DF-550E The DF-550E Nano Trace oxygen analyser is a Coulometric sensor based analyser designed to measure oxygen as a contaminant at ultra trace levels in ultra high purity electronic
More informationInstruction Manual Differential Pressure Transmitter
DE61 Instruction Manual Differential Pressure Transmitter Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance
More informationVACUUM REGULATORS CONTENTS
CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate
More informationModel PDT Dewpoint Transmitter
Model PDT Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk
More informationModel NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters
Data Sheet DS/NDA-EN Rev. H Model NDA Differential pressure transmitter Deltapi N Series A complete range of pneumatic pressure transmitters Introduction The blind type differential pressure transmitter
More informationHot extractive multi-channel gas analyser for continuous process and emissions monitoring.
Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions
More informationTC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER OUTLINE FEATURES OPERATION PRINCIPLE
FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES TC Series THERMAL MASS FLOW CONTROLLER OUTLINE TC series are thermal mass flow controllers, a combination of thermal mass flowmeter and control valve. TC
More informationEPP4 Pressure Regulator Basic G 1/4"
EPP4 Pressure Regulator Basic G 1/4" Flow Curve 1/4" Dimensions Outlet pressure - bar 9 8 7 6 5 4 3 2 1 0 0 20 40 60 70 80 100 120 Flow rate - Nm 3 /h The male connector adopted on the EPP4 is a standard
More informationSimple Set. Pressure Independent Control Valves 2 Way 1/2-2
The Bray Simple Set is a threaded pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SS Series combines high rangeability control
More informationMechanical Pressure Measurement
Mechanical Pressure Measurement Differential Pressure Gauges Model GDP, Universal Version, with Diaphragm Element High Overpressure Safety PN 40, 100, 250 or 400 Applications Differential pressure measurement
More informationSeries IRV1000/2000/3000
CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one
More informationIPH 2 & IPX 2. Features Type 4X & Explosion-Proof Current-to-Pressure (I/P) Transmitters. Approved for Use with Natural Gas.
February 2018 Description These 2-wire (loop-powered) I/P transmitters accept a current signal (such as 4-20mA) from a DCS, PLC or PC-based control system. They convert the current signal to a pneumatic
More informationFTC130 Transmitter. Operating Manual
Seite 1 von 11 FTC130 Transmitter Fast Thermal Conductivity Analyzer Operating Manual 1.09KD180724CWI1V05 Messkonzept GmbH Seite 2 von 11 1. Intended Use... 3 2. Description... 4 3. Measuring gases and
More informationFAS-W. Features. Applications. Automatic condensation hygrometer
FAS-W HUMIDITY ANALYZER Automatic condensation hygrometer the «FAS-W» Moisture Analyzer automatic condensation hygrometer can measure both the volume fraction of moisture and the dew point temperature
More informationElectro-Pneumatic Valve Positioners
o. SS2-HEP180-0100 OVERVIEW FM Explosionproof approval Electro-Pneumatic Valve Positioners Mounted on control valves, HEP Electro-Pneumatic Valve Positioners model HEP18/19/28/29 control valve positions
More informationCSA Sample Draw Aspirator Adapter Operator s Manual
30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More informationSSL. Smart Valve Positioner.
Smart Valve Positioner Smartest valve control device meeting a dynamic performance and a precise setting with a piezoelectric technology and an optimized auto-calibration program Features Auto-Calibration
More information780S Ultra High Purity Series
Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no seperate temperature or pressure inputs required Field adjustment of critical flow meter settings via on-board
More informationPrecision pressure sensor Basic version Model CPT6020
Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications
More informationAutocalibration Systems for In Situ Oxygen Analyzers
Product Data Sheet PDS 106-340AC.A01 February, 2006 SPS 4001B, IMPS 4000 and MPS 3000 Autocalibration Systems for In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
More informationVortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing
Vortex Flow Sensor VA Di Ex-d Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing Drawing 1 Measurable variables actual flow rate actual
More informationBooster Regulator/Air Tank
Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed
More informationModel 601CV. Mass Flow Controller. Product Features:
Model 601CV Mass Flow Controller Porter s Model 601CV Series II Mass Flow Controller (MFCs) is designed for precise control of virtually all conventional process gases. The MFC consists of a thermal mass
More informationElectropneumatic Transducer (I/P) Installation, Operation and
Nitra NCP1 Series Electropneumatic Transducer (I/P) Installation, Operation and Maintenance Instructions Ordering Information Contents Part Number I/P Transducers Output Range Input psig bar Section Description
More informationUser and Installation Manual
COMBUSTION ANALYSERS SERVOTOUGH Fluegas(2700) 2730C Utilities Unit User and Installation Manual Part Number: 02730001C Revision: 1 Language: UK English This page intentionally blank CONTENTS LIST CONTENTS
More informationKMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N
Thermal Mass Flow Meter for Compressed Air and Gases measuring monitoring analysing KMT Measuring range: 0.32... 63 m3n/h... 3.5... 1400 m3 N /h Accuracy: ±2,5% of reading + 0,15% of full scale p max :
More information10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor
2-Color Display High-Precision Digital Pressure Switch Series ZSEA(F)/EA ZSE E RoHS New IP65 ZSE E ZSE0 E0 M8 connector type E70 ZSE E E Applicable Air, Non-corrosive gas, Non-flammable gas fluid Can copy
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 2 mm
0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-12 Quick mounting bracket with dead stop BF 12 Mounting flange, 12 mm Technical Data specifications Switching
More informationL3 Pressure and Level transmitter
SENSORS FOR AND BIOPHARMA. Product Information L3 L3 Pressure and Level transmitter Range of applications Hydrostatic Level measurement in dynamic temperature environments Pressure measurement in pipes
More informationModel ZR202G Integrated type Zirconia Oxygen Analyzer
User s Manual Model ZR202G Integrated type Zirconia Oxygen Analyzer R 7th Edition Introduction The EXAxt ZR Integrated type Zirconia Oxygen Analyzer has been developed for combustion control
More informationOxygen Flue Gas Analyzer BA 2000
Gas Analysis Oxygen Flue Gas Analyzer BA 2000 Some combustion processes, e.g. process heaters, steam boilers or heating furnaces the air required to achieve optimal system efficiency can easily fluctuate.
More informationPressure Automated Calibration Equipment
GE Measurement & control Pressure Automated Calibration Equipment Safety Instructions and User Guide - K0447 PACE5000 PACE6000 K0447 Issue No. 9 1 10 1 PACE5000 1 2 3 4 5 PACE6000 2 6 7 8 3 4 5 6 7 8 9
More informationMULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE
SIT Group SIT -3- SIGMA MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE 9.955. Subject to change without notice Application Domestic gas appliances: central heating boilers, combi boilers, instantaneous
More information