1 South Texas Landfill Case Study During 2011, four QED Precision Fine Tune Control Valves were installed in wells at a south Texas landfill. The following graphs show the composition of the landfill gas and flow data before and after the installation of the Control Valves in Wells 07, 54, 78, and 90. The closest neighboring well on the same trunk line, using a gate valve for flow control, was also chosen for an additional comparison. The screen shot (at right) shows the increase in value of the methane produced at Well 90 resulting from the increase in concentration and flow.
2
3 Well 07 Complete Wellhead Installation The new QED Wellhead installation on Well 07 has reduced balance gases and maintained the flow of methane. After installation of the Wellhead and Control Valve on Well 07, balance gases have been reduced and the flow of methane was maintained or steadily increased. Because of high oxygen levels, neighboring Well 08 has been and remains in exceedance of NSPS regulations. Well 08 neighbors Well 07, and does not have a QED Control Valve. With its oxygen concentration issues it is continually out of compliance.
4 Well 54 Fine Tune Control Valve Installation The QED Control Valve installed on Well 54 has reduced the balance gas concentration and increased methane production. Well 54 had several compliance issues in 2010, such as oxygen levels spiking to 20% in December, prior to the installation of the Control Valve. After installation, methane production has increased, and the oxygen concentration has been reduced keeping the Well in compliance. Neighboring Well 55, on the same trunk line, continues to have big spikes in balance gases and big drops in methane production. Well 55 neighbors Well 54, and does not have a QED Control Valve, it has major compliance issues because of oxygen spikes.
5 Well 78 Complete Wellhead Installation The new QED Wellhead installation on Well 78 has reduced oxygen and balance gas concentrations, and steadily increased methane production. Well 78 also had compliance issues in But once the Wellhead and Control Valve were installed, methane production has been steadily rising, and balance gas and oxygen levels have been reduced. Well 78 now remains in compliance. Neighboring Well 25, on the same trunk line, had flow, balance gas, and oxygen spikes in early 2012 putting it out of compliance. Well 25, which is a neighbor to Well 78 and does not have a QED Control Valve, has been out of compliance because of oxygen levels.
6 Well 90 Fine Tune Control Valve Installation The installation of a QED Control Valve put Well 90 back in compliance by controlling oxygen concentrations. Prior to the installation of the Control Valve, Well 90 was out of compliance because the oxygen concentration had increased to 6.4%. After installation, oxygen levels have been reduced helping maintain compliance, and methane production has increased. Neighboring Well 29, on the same trunk line, has had continuing compliance issues. Well 29 is a neighbor to Well 90 and does not have a QED Control Valve, it has continuing oxygen concentration compliance issues.
7 Case Study Conclusion The installation of QED Wellheads and Fine Tune Control Valves has clearly helped this south Texas landfill to improve gas flow and maintain compliance. All four of the wells had a reduction in balance gas and oxygen concentrations, and maintained a steady flow of methane. Vacuum was maintained on the wells resulting in additional methane collected over the entire time range of the study. The QED Fine Tune Control Valves allowed for linear flow adjustment even at flow rates under 10 cfm. The metered scale displayed the exact valve setting, with the rising stem making it clear how far the valve was open. In all cases, the Wellheads enabled the landfill to maintain measurable flow at the wells and keep oxygen under five percent.
Dewatering Landfill Gas Wells to Maximize LFG Collection
Dewatering Landfill Gas Wells to Maximize LFG Collection QED Environmental Systems Inc. Ann Arbor, Michigan - San Leandro, California Copyright QED Environmental Systems, Inc. 2013; all rights reserved.
More informationLandfill Gas Products
Landfill Gas Products Toll Free: 800-624-2026 www.qedenv.com info@qedenv.com 2355 Bishop Circle West Dexter, MI 48130, USA Phone: 734-995-2547 Fax: 734-995-1170 1670 Alvarado Street Ste. 5 San Leandro,
More informationOhio EPA. Division of Air Pollution Control. Engineering Guide #78. (also known as DSIWM Guidance Document #1001 and #1002)
Ohio EPA Division of Air Pollution Control Engineering Guide #78 (also known as DSIWM Guidance Document #1001 and #1002) Question: The Standards of Performance for New Stationary Sources (NSPS) for municipal
More informationREACTION RATES. The reaction rate is the progress of the reaction over time.
REACTION RATES To get started, let's think about what is meant by "rate". The rate of a reaction is just its speed. Just as your speed when driving down the highway can be described in terms of your progress
More informationLABORATORY EXERCISE 1 CONTROL VALVE CHARACTERISTICS
Date: Name: LABORATORY EXERCISE 1 CONTROL VALVE CHARACTERISTICS OBJECTIVE: To demonstrate the relation between valve stem position and the fluid flow through a control valve, for both linear and equal
More informationEmerging Issues in the Oil and Gas Industry
1 Emerging Issues in the Oil and Gas Industry Rocky Mountain EHS Peer Group Meeting April 16 th, 2015 Denver, CO by J.D.Danni OSHA Region VIII 2 Emerging Issues Tank Gauging Production Water Hazards Silica
More informationFlare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1
Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost HERMAN HOLM SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 4C CONFERENCE APRIL 2018 SAN ANTONIO, TX SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC
More informationINFLUENCE OF INITIAL PRESSURE ON THE IGNITION AND COMBUSTION OF A PROPELLING CHARGE. Patrice Franco
23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN 16-20 APRIL 2007 INFLUENCE OF INITIAL PRESSURE ON THE IGNITION AND COMBUSTION OF A PROPELLING CHARGE Patrice Franco French-German Research Institute
More informationIt s Just Calibration How Hard Can It Be?
It s Just Calibration How Hard Can it Be? Deever Bradley, P.E. Environmental Resources Management Bart Leininger, P.E. Principal Ashworth Leininger Group Camarillo, CA 4/3/18 Page 1 Objectives Proper instrument
More informationLow-Power Atmospheric Gas Sampling System Based on ART MS Sensor and NEG-Ion Pump
8 th Harsh Environment Mass Spectrometry Wokshop Low-Power Atmospheric Gas Sampling System Based on ART MS Sensor and NEG-Ion Pump Sept 22, 2011 Gerardo A. Brucker and G. Jeffery Rathbone Granville-Phillips
More informationOXYTEMP Instructions 1
OXYTEMP Instructions 1 Congratulations on purchasing your new OxyTemp Probe! ASSEMBLY INSTRUCTIONS FOR ECO-OXYGEN PROBES 1. Thread the stem into the bottom of the upper housing. 2. Tighten stem with a
More informationMETHOD 2E - DETERMINATION OF LANDFILL GAS PRODUCTION FLOW RATE. NOTE: This method does not include all of the
287 METHOD 2E - DETERMINATION OF LANDFILL GAS PRODUCTION FLOW RATE NOTE: This method does not include all of the specifications (e.g., equipment and supplies) and procedures (e.g., sampling and analytical)
More informationTP Validating a dynamic grid model with tracer gas injection and analysis
International Gas Research Conference 2014 TP3-12 433 Validating a dynamic grid model with tracer gas injection and analysis S.C. Brussel, R. Warmerdam, J. Weda, E. Hardi,T. van Onna, N. Ligterink, H.
More informationMedical Oxygen Concentrator Systems. Generate gases on site generate savings
Medical Oxygen Concentrator Systems Medical Oxygen is a critically important commodity to all Health Care Facilities (HCF s) How is Oxygen Supplied? Depending on the size and needs of the HCF, Oxygen can
More information_01_EE394J_2_Spring12_Texas_Synchrophasor_Events.doc. Events automatically detected by our PMU_Waveform_Analyzer. Event 1. Jan. 03, 2012.
Event 1. Jan. 03, 2012. 01:44 GMT -34-35 No wind generation. West Texas is importing power. -36 03 Straight-Line Miles 02 370 miles 100 miles 01 280 miles 22 Steady-state angle rises. 21 20 No unit tripped.
More informationGas Mixture Two Components. Gas Mixtures Two Components
Gas Mixture Two Components Two Components Contents Two-Component Mixtures Ammonia...M4 Argon...M5 Benzene...M6 n-butane...m7 Carbon Dioxide...M8 Carbon Monoxide...M10 Chlorine...M12 Ethane...M13 Ethylene
More informationDynamic Simulation for T-9 Storage Tank (Holding Case)
Dynamic Simulation for T-9 Storage Tank (Holding Case) CASE 1: 19,642 Kg/Hr (Holding: 52 o C), No Liquid Draw Workshop Description Estimation of vapor flow rate coming out from the T-9 tank for holding
More informationExhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)
1 APPLICABILITY Exhibit 4 Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N) Definitions common to all certification and test procedures
More informationLaser Spectrometers for Online Moisture Measurement in Natural Gas. Ken Soleyn GE M&C
Laser Spectrometers for Online Moisture Measurement in Natural Gas Ken Soleyn GE M&C ken.soleyn@ge.com Introduction TDLAS (Tunable Diode Lase Absorption Spectroscopy) Moisture Analyzers have become the
More informationHeat-Trapping Gases Lab
Heat-Trapping Gases Lab Before performing the lab, show this video to the students. http://spark.ucar.edu/greenhouse-effect-movie-scott-denning Objective: The main goal of this activity is instrumentally
More informationCommercial Practice Test Method Internal Vapor Analysis of Hermetic Devices
Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices Oneida Research Services, Inc. 8282 Halsey Road Whitesboro, NY 13492 Phone: (315) 736-5480 FAX: (315) 736-9321 1.0 Purpose The
More informationSIZING AND CAPACITIES OF GAS PIPING Reserved
APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 529R APPENDIX A SIZING AND CAPACITIES OF GAS PIPING This page left intentionally blank. 530R 2003 INTERNATIONAL
More informationPROVING THAT BLADDER SURGE TANKS CURED EXCESSIVE SURGE CONDITIONS IN A 30 FORCE MAIN
Background PROVING THAT BLADDER SURGE TANKS CURED EXCESSIVE SURGE CONDITIONS IN A 30 FORCE MAIN Bo, P.E., Hazen and Sawyer, P.C. Sean FitzGerald, P.E., Hazen and Sawyer, P.C. The Sanitation District No.
More information1. Study the performance of a binary distillation column operated in batch mode.
Goals for batch distillation using the East distillation column: 1. Study the performance of a binary distillation column operated in batch mode. 2. Determine the overall and local efficiency of the column
More informationChamber Test Testing Theory
Chamber Test Testing Theory A chamber test is used to find leaks in sealed packaging or sealed devices without an opening to use for filling. To test the part, a technique called meteredvolume fill must
More informationMETHOD 204F--VOLATILE ORGANIC COMPOUNDS CONTENT IN LIQUID INPUT STREAM (DISTILLATION APPROACH) 1.1 Applicability. This procedure is applicable for
METHOD 204F--VOLATILE ORGANIC COMPOUNDS CONTENT IN LIQUID INPUT STREAM (DISTILLATION APPROACH) 1. INTRODUCTION 1.1 Applicability. This procedure is applicable for determining the input of volatile organic
More informationSpot the Hazards: Review Confined Space Hazards Missed by Most Safety Professionals, and the PPE Solutions that Meet OSHA Requirements
Spot the Hazards: Review Confined Space Hazards Missed by Most Safety Professionals, and the PPE Solutions that Meet OSHA Requirements Why is Gas Detection Important? Spot the hazard Composition of Fresh
More informationBoyle s Law: Pressure-Volume Relationship in Gases. PRELAB QUESTIONS (Answer on your own notebook paper)
Boyle s Law: Pressure-Volume Relationship in Gases Experiment 18 GRADE LEVEL INDICATORS Construct, interpret and apply physical and conceptual models that represent or explain systems, objects, events
More informationChapter 13 Gases, Vapors, Liquids, and Solids
Chapter 13 Gases, Vapors, Liquids, and Solids Property is meaning any measurable characteristic of a substance, such as pressure, volume, or temperature, or a characteristic that can be calculated or deduced,
More informationSG TF. Q = 963 Cv (P1 - P2)(P1 + P2) TECHNICAL INFORMATION. Flow Q (GPM)
TECHNICAL INFORMATION BuTech designs all pressure-containing equipment to meet or exceed the applicable requirements of Section VIII, Division1 or Division 2 of the ASME Boiler and Pressure Vessel Code
More informationVALVE MANUFACTURERS ASSOCIATION API 622 API 624
VALVE MANUFACTURERS ASSOCIATION API 622 API 624 Written by Rich Davis Manager Business Development Western Hemisphere & China Flexitallic L.P., Deer Park, Texas Presented By: Steve Butler, Shell Global
More informationOperating Instructions
Operating Instructions Preparation for Start-up 1. If the computer system is logged off, log into the computer system. Log into the operator account on the computer. Please ask your TA for username and
More informationSelf-operated Pressure Regulators for special applications
Self-operated Pressure Regulators for special applications Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Application Pressure regulators for cryogenic
More informationMultiple Gas#5 GC configuration Jan 2016
History: Unfortunately there is no single column that can separate: Hydrogen Oxygen Nitrogen Methane CO CO2 Ethane Water Propane Butane Pentane Over the years SRI Instruments has devised several solutions
More informationSupersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.
Bulletin Category: GAS Bulletin: G-23 Page: 1 of 7 The copy of this document located on Measurement Canada s website is considered to be the controlled copy. Recognition of data from specialty gas suppliers
More informationCASE STUDY. Elvington To Brayton Barff Air valve replacement Program
CASE STUDY Elvington To Brayton Barff Air valve replacement Program Vent-O-Mat Anti-Shock Air valves have helped Yorkshire Water reduce maintenance costs, reduces surge and improve flows in their trunk
More informationProposed Uniform Standards for Equipment Leaks
12 th LDAR Symposium May 15-16, 2012 New Orleans, LA Proposed Uniform Standards for Equipment Leaks Standards Certification Education & Training Publishing Conferences & Exhibits 1 Proposed LDAR Uniform
More informationSchedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT
S. No 1 Description Calorimeter The Unit should be designed for the accurate determination of the calorific value of liquid and solid hydrocarbons and other fuels. Specifications: A temperature-controlled
More informationX-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司
X-Flow Mass Flow Controller 2 Highlights Parker Hannifin Precision Fluidics Division is excited to introduce X-Flow, a new easy to use general purpose mass flow controller for your instrument, lab, or
More informationAmerican Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM
American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1018 - REVISED: 2001 Trap Seal Primer Valves - Potable Water Supplied MANUFACTURER: CONTACT PERSON: E-MAIL: ADDRESS:
More informationAutomated Determination of Dissolved Gases in Water By Headspace Calibration of Mixed Gases Anne Jurek
Automated Determination of Dissolved Gases in Water By Headspace Calibration of Mixed Gases Anne Jurek Abstract: Due to the expansion of natural gas drilling through horizontal fracturing, there has been
More informationLow gas volume & flow measurements made easier Gas Endeavour
Low gas volume & flow measurements made easier Gas Endeavour www.bioprocesscontrol.com Low gas volume and flow high accuracy and precision Measure gas volume and flow for a wide range of applications The
More informationAutomated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:
Automated Determination of Dissolved Gases in Water Anne Jurek Abstract: The RSK-175 standard operating procedure was developed in order to determine the amount of dissolved gas in water. Due to the expansion
More informationSubject: FW: 2018 First Quarter Probe/Perimeter Monitoring Report Lena Road Landfill WACS # 44795
Borderieux, Scott From: Thompson, Madison Sent: Wednesday, May 16, 2018 3:48 PM To: Borderieux, Scott Subject: RE: 2018 First Quarter Probe/Perimeter Monitoring Report - Lena
More informationZUERCHER TANK REGULATORS PRINCIPLES OF TANK VENTILATION
Why Inertisation (blanketing) of Tanks? General Tank inertisation or blanketing is required in many applications where products or liquids stored in the tank are processed and/or filled into and emptied
More informationDraeger Fabius GS Pre-Use Check
Draeger Fabius GS Pre-Use Check James H Philip MEE, MD, CCE 2011 James H Philip All rights reserved Remember to enter Machine # Fabius GS front view Fabius GS pre-use checkout procedure Fabius GS pre-use
More informationBoyle s Law. Pressure-Volume Relationship in Gases. Figure 1
Boyle s Law Pressure-Volume Relationship in Gases The primary objective of this experiment is to determine the relationship between the pressure and volume of a confined gas. The gas we use will be air,
More informationValve Communication Solutions Axiom
Axiom Detect automated valve problems... before they shut down your process Reasons for Automated On/Off Valve Failures Monitor Fail Solenoid Fail Actuator Fail Coupling Break Too Slow Leaking Sticking
More informationADVANCED CONTROL VALVE AND ACTUATOR: Selection, Calculations, Sizing, Applications, Operation, Diagnostic Testing, Troubleshooting and Maintenance.
Training Title ADVANCED CONTROL VALVE AND ACTUATOR: Selection, Calculations, Sizing, Applications, Operation, Diagnostic Testing, Troubleshooting and Maintenance. Training Duration 5 days Training Dates
More informationMass Flow Controllers
Mass Flow Meters & Controllers HFM-D-3A & 305A Mass Flow Meters HFC-D-3A & 307A Mass Flow Controllers FEATURES Range 0-25 slm to 0-2500 slm (N 2 Equivalent) Excellent Accuracy ±(0.5% of Reading + 0.2%
More informationVS Series Leak Detectors for Vacuum Furnaces LEAK DETECTION FOR VACUUM FURNACES
VS Series Leak Detectors for Vacuum Furnaces LEAK DETECTION FOR VACUUM FURNACES VS Series Leak Detectors for Vacuum Furnaces indicate the presence of a leak. If the vacuum level is slow to reach the original
More informationLINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER
LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER Michael T Tang, Ph.D. Grace Feng Greg Merideth Rui Huang Matheson Gas Applied Lab
More informationPolyethylene Valves for Natural Gas.
Polyethylene Valves for Natural Gas. Providing valves and equipment to the world s energy markets for over 00 years. Polyethylene Valves Made in the U.S.A. The POLYBALL valve is manufactured at our Mansura,
More informationResponding to Natural Gas Pipeline Emergencies
Responding to Natural Gas Pipeline Emergencies Who is Florida Gas Transmission? Florida Gas Transmission operates nearly 5,000-miles of interstate natural gas transmission pipelines, a system that extends
More information27Quantify Predictability U10L9. April 13, 2015
1 QUANTIFYING PREDICTABILITY Exercise #1: Make sure that your calculator has its r value on. 2 Exercise #2: In the following exercises four data sets with equal x values are given to illustrate different
More informationOperational Settings:
instrucalc features more than 70 routines associated with control valves, ISO flow elements, relief valves and rupture disks, and calculates process data at flow conditions for a comprehensive range of
More informationOerlikon Sputtering Evaporator SOP
Oerlikon Sputtering Evaporator SOP Short UNT Cleanroom 1. Taking out sample holder from Transport Chamber : Log in FOM to access the software Go to the software and log in with user1 and password user1
More informationACV-10 Automatic Control Valve
ACV-10 Automatic Control Valve Installation, Operation & Maintenance General: The Archer Instruments ACV-10 is a precision automatic feed rate control valve for use in vacuum systems feeding Chlorine,
More informationGases NO CALCULATORS MAY BE USED FOR THESE QUESTIONS
NO CALCULATORS MAY BE USED FOR THESE QUESTIONS Questions 1-3 refer to the following gases at 0 C and 1 atm. (A) Ar (B) NO 2 (C) Xe (D) H 2 (E) N 2 1. Has an average atomic or molecular speed closest to
More informationTyler Runge and Kelly McCaffrey. The Dynamic Relation between String Length and Height with a Set Mass
The Dynamic Relation between String Length and Height with a Set Mass Introduction: The purpose of this experiment was to find the relation between string length and height while keeping the mass constant
More informationON-SITE OXYGEN GENERATION WHY PSA SYSTEMS ARE A GOOD CHOICE
TRIDENT NOTES: NUMBER 4 APRIL 2017 ON-SITE OXYGEN GENERATION WHY PSA SYSTEMS ARE A GOOD CHOICE The consumption of oxygen in hospitals has been rising steadily for decades now. According to the sixth edition
More informationGEM 2000 GAS ANALYZER & EXTRACTION MONITOR OPERATION MANUAL
GEM 2000 GAS ANALYZER & EXTRACTION MONITOR OPERATION MANUAL Copyright 2001 by CES-LANDTEC All rights reserved. Printed in the United States of America. No part of this book may be used or reproduced in
More informationSF 6 Product Guide. Gas Analysis Instruments and Accessories
SF 6 Product Guide Gas Analysis Instruments and Accessories Cambridge Sensotec Ltd specialises in the design and manufacture of gas analysis equipment under the Rapidox brand name. Based in the UK, the
More informationOur Air- Why We Should Care!
Our Air- Why We Should Care! We live on earth, but we live in its atmosphere- a mixture of gases we call air. Just as water surrounds aquatic life, air surrounds us. People seldom think about the sea of
More informationApplications Note: Use of "pentane equivalent" calibration gas mixtures
Introduction The gas that is used to verify accuracy is every bit as important as the detector itself when it comes to worker safety. Choosing (and using) the right mixture is critical to the success of
More informationSMART Explosion. Efficient Boiler Cleaning with Explosion Generators
SMART Explosion Efficient Boiler Cleaning with Explosion Generators Problem and Solution The use of solid fuels, such as coal, waste or biomass, is liable to intense fouling of the steam generator heating
More informationThe University of Hong Kong Department of Physics Experimental Physics Laboratory
The University of Hong Kong Department of Physics Experimental Physics Laboratory PHYS2260 Heat and Waves 2260-1 LABORATORY MANUAL Experiment 1: Adiabatic Gas Law Part A. Ideal Gas Law Equipment Required:
More informationOMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.
OMNISTAR / THERMOSTAR The efficient solution for gas analysis. Intelligent software. Wide range of applications. OMNISTAR /THERMOSTAR The efficient solution for gas analysis. Intelligent software. Wide
More informationGEM 2000 GAS ANALYZER & EXTRACTION MONITOR OPERATION MANUAL
GEM 2000 GAS ANALYZER & EXTRACTION MONITOR OPERATION MANUAL Copyright 2003 by CES-LANDTEC All rights reserved. Printed in the United States of America. No part of this book may be used or reproduced in
More informationSummary of Substantive Changes between the 2004 e1 and 2017 editions of ASSE 1011, Hose Connection Vacuum Breakers
Summary of Substantive Changes between the 2004 e1 and 2017 editions of ASSE 1011, Hose Connection Vacuum Breakers Presented to the IAPMO Standards Review Committee on October 15, 2018 General: The changes
More informationACCU-FLO WELLHEAD Installation and Operation Manual
ACCU-FLO WELLHEAD Installation and Operation Manual ACCU-FLO Wellhead Table of Contents ACCU-FLO WELLHEAD GUARANTEE... 1 OWNER REGISTRATION... 1 ADDITIONAL INFORMATION AND TECHNICAL ASSISTANCE... 1 INTRODUCTION...
More informationThe Gas Attenuator of FLASH
INTRODUCTION The Gas Attenuator of FLASH K. Tiedtke, N. von Bargen, M. Hesse, U. Jastrow, U. Hahn The experimental hall of the FLASH user facility is located approximately 30m behind the last dipole magnet
More informationGEM-500 OPERATION MANUAL
GEM-500 OPERATION MANUAL Copyright 2001 by CES-LANDTEC All rights reserved. Printed in the United States of America. No part of this book may be used or reproduced in any form or by any means, or stored
More informationEXPIRATION DATE: (FOR RENEWAL, SEE 49 CFR ) 1. GRANTEE: Structural Composites Industries (SCI) Pomona, CA
East Building, PHH-30 1200 New Jersey Avenue S.E. U.S. Department of Transportation Washington, D.C. 20590 Pipeline and Hazardous Materials Safety Administration DOT-SP 13583 (NINTH REVISION) EXPIRATION
More informationAutomated Determination of Dissolved Gases in Water Anne Jurek
Automated Determination of Dissolved Gases in Water Anne Jurek Abstract: Tapping the natural gas reservoirs throughout the United States has long been a viable solution for energy independence; however
More informationSelf-operated Pressure Regulators Type 2405 Pressure Reducing Valve
Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve ANSI version Application Pressure reducing valve for set points from 0.075 to 150 psi (5 mbar to 10 bar) Valve size NPS ½ to 2 1) (DN
More information1. What function relating the variables best describes this situation? 3. How high was the balloon 5 minutes before it was sighted?
Hot-Air Balloon At the West Texas Balloon Festival, a hot-air balloon is sighted at an altitude of 800 feet and appears to be descending at a steady rate of 20 feet per minute. Spectators are wondering
More informationLeak Checking Large Vacuum Chambers
Leak Checking Large Vacuum Chambers Technical Overview Vacuum Technologies Introduction Understanding the pump-down characteristics of a large vacuum vessel is critical for determining whether the vacuum
More informationPilgrim Hot Springs Flow Testing
INTRODUCTION Pilgrim Hot Springs Flow Testing PS 13-1 Air Lifted Flow Testing September 15-17, 2014 Prepared by: Dick Benoit, Chris Pike and Gwen Holdmann October 7, 2014 The Alaska Center for Energy and
More information3 Acetylene. Acetylene. The fuel gas of choice
3 The fuel gas of choice 02 03 Consult the experts. Finding the fuel gas that works best for you. High speed, lower costs. Profit from the many benefits of acetylene. Your choice of fuel gas is fundamental
More informationBarrier Development and Evaluation Methodology. D.S. Musgrave 1 1 Thermal Visions, Inc., Granville, USA
Barrier Development and Evaluation Methodology D.S. Musgrave 1 1 Thermal Visions, Inc., Granville, USA 1. Introduction: Vacuum insulation is now a rapidly expanding market and technical advances are being
More informationT 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version
T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version Application Excess pressure valve for set points from 0.075 to 150 psi (5 mbar to 10 bar) Valve size NPS ½ to 2
More informationCALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO Walnut Lake Rd th Street Houston TX Garner, IA 50438
CALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO. 10 Jerry Paul Smith Joel Clancy JPS Measurement Consultants, Inc Colorado Engineering Experiment Station, Inc (CEESI) 13002 Walnut Lake
More informationThis educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum.
This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum. Specifically, today s talk will cover: Brief review of Vacuum Fundamentals Applications Using Rough Vacuum Rough
More informationGases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.
Gases&Technology FEATURE Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. B Y M A T T H E W M O N A G L E Abstract Bulk gases are often delivered to
More informationLab #12:Boyle s Law, Dec. 20, 2016 Pressure-Volume Relationship in Gases
Chemistry Unit 6:States of Matter & Basic Gas Laws Name Lab Partner Lab #12:Boyle s Law, Dec. 20, 2016 Pressure-Volume Relationship in Gases Purpose: The primary objective of this experiment is to determine
More informationFig 3, 7, 33, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers
16352/8 IM-S6-18 ST Issue 8 Fig 3, 7, 33, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation
More informationLINEAR MOTION. General Review
LINEAR MOTION General Review 1. Velocity is to speed as displacement is to A. acceleration B. momentum C. time D. distance 1. Velocity is to speed as displacement is to A. acceleration B. momentum C. time
More informationMitos Fluika Pressure and Vacuum Pumps Datasheet
Unit 1, Anglian Business Park, Orchard Road, Royston, Hertfordshire, SG8 5TW, UK T: +44 (0)1763 242491 F: +44 (0)1763 246125 E: sales@dolomite-microfluidics.com W: www.dolomite-microfluidics.com Dolomite
More informationVOC Emissions From the Drying of Red Alder Lumber
VOC Emissions From the Drying of Red Alder Lumber Report to Cascade Hardwoods Report by Michael R. Milota Department of Wood Science and Engineering Oregon State University Corvallis, OR 97331 February
More informationAmerican Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM
American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1019 - REVISED: 2011 Wall Hydrant with Backflow Protection and Freeze Resistance MANUFACTURER: CONTACT PERSON: E-MAIL:
More informationCarrier Gases in Capillary GC
Carrier Gases in Capillary GC LC Columns and Consumables Mark Sinnott Application Engineer January 15, 2009 CARRIER GAS Mobile Phase Carries the solutes down the column Selection and velocity influences
More informationPrecision Calibration Gas
Precision Calibration Gas Setting Standards - Exceeding Expectations GASCO is an organization characterized by integrity, competence, cooperation and professionalism. We continually strive to earn customers
More informationGulfstream Natural Gas System
Website: www.gulfstreamgas.com Gulfstream has prepared this fact sheet as a guide for emergency response officials who may be asked to respond to an incident involving a Gulfstream natural gas pipeline
More informationMEASURING WATER CONTENT IN COMPRESSED BREATHING AIR IN COMPLIANCE WITH EN 12021:2014 ULTRA-PRECISE AND ULTRA-RELIABLE WITH POLYMER TECHNOLOGY
MEASURING WATER CONTENT IN COMPRESSED BREATHING AIR IN COMPLIANCE WITH EN 12021:2014 ULTRA-PRECISE AND ULTRA-RELIABLE WITH POLYMER TECHNOLOGY SPORTS & SAFETY BAUER KOMPRESSOREN WHY PRECISE MEASUREMENT
More informationTwo types of physical and biological standards are used to judge the performance of the Wheeler North Reef 1) Absolute standards are measured against
1 Two types of physical and biological standards are used to judge the performance of the Wheeler North Reef 1) Absolute standards are measured against fixed value at Wheeler North Reef only 2) Relative
More informationA versatile gas mixing system for blending LPG and air that is SAFE, RELIABLE, and EASY TO USE
A versatile gas mixing system for blending LPG and air that is SAFE, RELIABLE, and EASY TO USE A versatile gas mixing system for blending LPG and air that is SAFE, RELIABLE, and EASY TO USE Contents The
More informationAPPENDIX P U.S. EPA WARM MODEL OUTPUT
APPENDIX P U.S. EPA WARM MODEL OUTPUT Analysis Inputs Version 12 Waste Reduction Model (WARM) -- Inputs Use this worksheet to describe the baseline and alternative MSW management scenarios that you want
More informationHydronic Systems Balance
Hydronic Systems Balance Balancing Is Misunderstood Balancing is application of fundamental hydronic system math Balance Adjustment of friction loss location Adjustment of pump to requirements By definition:
More informationDELTI. Vac. DELTI-Vac MIL. Application. Principle. Characteristic
- MIL - presents the most complex versatile and variable system for stability Application Monitoring of chemical stability is essential for reliable risk and safety management of single or double based
More information