Booster sets, pressurisation units, water storage tanks, waste water solutions and rainwater harvesting

Size: px
Start display at page:

Download "Booster sets, pressurisation units, water storage tanks, waste water solutions and rainwater harvesting"

Transcription

1 Booster sets, pressurisation units, water storage tanks, waste water solutions and rainwater harvesting Aquatech Pressmain is an AGM brand.

2

3 Although the name Aquatech Pressmain may not be familiar to you, it s likely that we re already a part of your everyday life. With more than seventy years experience, we are market leaders in the supply of water pressure booster sets and pressurisation units to the building services, process and water industries. As part of AGM plc, Aquatech Pressmain offers a broad range of expertise and experience to meet the diverse requirements of our customers. We re proud to say that we re the only UK company to design and produce our own in-house microprocessor control systems, enabling us to offer unrivalled versatility in meeting the specific needs of a project. We also work with clients and consultants to design and build bespoke products for specialised applications. Providing regional support from our offices in Colchester and Manchester, our sales and service network covers the whole of the United Kingdom as well as international markets. Aquatech Pressmain is ISO 9001 accredited for both the design and manufacture of bespoke packaged pump systems and is also PED (Pressure Equipment Directive) Compliant. We offer a complete, quality-assured solution to your requirements, quickly, efficiently and at a competitive price. Our product portfolio includes: Booster sets for CAT5 systems, hot and cold water supplies Pressurisation units for sealed heating and chilled water systems Water storage and controls Waste water pump systems Rainwater harvesting systems Our other services include: Maintenance and installation Emergency cover Water quality monitoring Water hygiene Waste water services Replacement parts Commissioning BOOSTER SETS 2 E.SYLINE BOOSTER SET SERIES 4 E.SYLINE BOOSTER SET PACKAGED SOLUTIONS 5 BESPOKE BOOSTER SETS 5 BOOSTER SET CASE STUDIES 6 WATER STORAGE AND CONTROLS 8 PRESSURISATION UNITS 10 PRESSURISATION UNIT CASE STUDIES 13 RAINWATER HARVESTING 14 WASTE WATER PRODUCTS 15 OTHER AGM SERVICES 16

4 BOOSTER SETS Cold water pressure booster sets for increasing the pressure in wholesome drinking water. Available with 1 to 8 pumps. AQUABREAK AB5 Single point outlet, CAT5 boosted water supply. Duty range Flows to 0.3 l/s Heads to 1.5 bar Temperature 0 C to 35 C Max pressure 6 bar Single pump, complete with 5 litre breaktank and Type AB Air Gap Data Sheet 145 MONOMATIC MC5 Domestic or light commercial CAT5 boosted water supply. Duty range Flows to 1.2 l/s Heads to 4.5 bar Temperature 0 C to 35 C Max pressure 7 bar Single pump, complete with 65 litre breaktank and Type AB Air Gap Data Sheet

5 AQUAMATIC AMV-FB BASIC SERIES VARIABLE SPEED NEW EXTENDED RANGE All variable speed driven pumps are energy efficient for potable water distribution or pressure boosting in residential, commercial and industrial premises. Duty range Pumps 2 to 4 Flows to 28 l/s Heads to 14.0 bar Supplied with standard controls 304 stainless steel pipework Flow through vessel Data Sheet 128 AQUAMATIC AMV-FE ENHANCED SERIES VARIABLE SPEED All variable speed driven pumps are energy efficient for potable water distribution or pressure boosting in residential, commercial and industrial premises. Duty range Pumps 2 to 6 Flows to 48 l/s Heads to 14.0 bar Supplied with 2020 Plus Controller as standard 304 stainless steel pipework Flow through vessel The enhanced AMV-FE offers variable speed motors that continuously alter their speed to match fluctuating system flow rates. Combined boosting and sprinkler options available in line with BS9251:2014. Data Sheet 123 AQUAVENT REFILL VALVE FOR BOOSTED WATER SYSTEMS Designed to help assist with the draining down and refilling of pressure boosted water supply pipework by helping to prevent damaging pressure shocks from occurring. Whether a system pipework is drained down intentionally for maintenance or unintentionally as a result of the pressure booster set stopping, either by power interruption or a low water condition there is the potential of pressure shocks when the pressure booster restarts. Data Sheet 507 Call +44 (0)

6 E.SYLINE BOOSTER SET SERIES Cold water pressure booster sets for increasing the pressure in wholesome drinking water. NEW E.SYLINE MINI Small dwelling potable water booster Variable speed Duty range Flows to 1.3 l/s (single pump) Heads to 5.5 bar Temperature 0 C to 40 C Max pressure 6 bar Data Sheet 140 NEW E.SYLINE BOX Medium dwelling potable water booster Variable speed Duty range Flows to 1.5 l/s (single pump) Heads to 5.5 bar Temperature 0 C to 40 C Max pressure 6 bar Data Sheet 140 NEW E.SYLINE TWIN Large dwelling potable water booster Variable speed Duty range Flows to 1.5 l/s (single pump) Flows to 3.0 l/s (twin pump) Heads to 5.5 bar Temperature 0 C to 40 C Max pressure 6 bar Data Sheet

7 E.SYLINE BOOSTER SET PACKAGED SOLUTIONS E.Syline range of booster pumps can be supplied fully packaged with various water storage tank options and supplied with Air Gap packs. E.SYLINE MINI with 65L Storage Tank E.SYLINE TWIN with 700L Storage Tank OTHER TANK COMBINATIONS AVAILABLE Contact our sales office for more information BESPOKE BOOSTER SETS Bespoke cold water pressure booster sets for increasing the pressure in wholesome drinking water. Available with 1 to 8 pumps. AQUAMATIC BESPOKE PUMPSETS with 2020 Plus Controller All variable speed driven pumps are energy efficient for potable water distribution or pressure boosting in residential, commercial and industrial premises. Duty range Flows to 204 l/s Heads to 25 bar Supplied with 2020 Plus Controller as standard All pumps are energy efficient with variable speed motors that continuously alter their speed to match fluctuating system flow rates. COMBINED BOOSTER AND SPRINKLER SETS AVAILABLE ON REQUEST Standard in line with BS9251 guidance Call +44 (0)

8 BOOSTER SET CASE STUDIES COSTA COFFEE Location: Basildon, Essex, United Kingdom Client: Costa Coffee Product: Pressure Booster and Break Tank The new Costa coffee roastery in Basildon, Essex built for Costa to meet the growing UK market has three large coffee roasters, capable of producing enough coffee for approximately 2.1 billion cups a year. Aquatech Pressmain were asked to supply a packaged water booster pump set with storage water tank which keeps the production process fully compliant with water supply regulations. WYTHENSHAWE HOSPITAL Location: Wythenshawe, Manchester, UK Client: NHS Product: 5 Pump Custom Pressure Booster Set The hospital wished to modernise the existing potable water supply and the control of the heating system. Aquatech Pressmain were asked to recommend equipment solutions that would provide longevity, reliability but most of all energy efficiency. The existing system included water tanks housed in a water tower which was due for demolition so a new water booster and heating pressurisation unit was required.once the water usage and pattern of demand was determined, Aquatech Pressmain built and supplied a new five pump water booster set and twin pump pressurisation unit, fitted with Aquatech Pressmain s own controller and energy efficient, intelligent variable speed pumps which together are able to meet the hospital s complex and varied needs. 6 The plant room for the booster set was underground so it was built in situ enabling a smooth transfer from the existing pump set, with no disruption to the hospital s water supply. As the new equipment only runs when required there is a saving on electricity as well as the saving on maintaining water tanks which are no longer needed.

9 TRELAWNEY HOUSE Location: Business centre in Bristol, England Client: EPG Contracting Product: Pressure Booster Set This stunning development of studio, one and two bed apartments in the heart of Bristol, boasts an Aquatech Pressmain water pressure booster set. Ensuring that when the residents turn on their taps after work, they will be able to have that quick shower and head out to enjoy the nightlife that this vibrant city has to offer. HAMMOND HOUSE & DICKSON HOUSE Location: Stoke-on-Trent, United Kingdom Client: JPR Engineering Product: Pressurisation Units, two Water Boosters and Circulating Pumps For the flats at Hammond House & Dickson House in Hanley, Stoke on Trent, Aquatech Pressmain visited the site, undertook a full survey, including checks of all existing plant rooms and produced a in-depth proposal including bespoke solutions for a leading Mechanical and Electrical company in Stoke; JPR Engineering, who installed Pressurisation Units, two Water Boosters and three Circulating Pumps all designed and built for the project by Aquatech Pressmain. By using the knowledge and expertise of Aquatech Pressmain and JPR Engineering collectively, the owners of Hammond House & Dickson House, have a bespoke water supply and heating system which is more efficient, more energy efficient and will save them and their tenants money. Call +44 (0)

10 WATER STORAGE AND CONTROLS We provide a range of water storage solutions and monitoring equipment for the level and/or temperature of fluid in tanks. TANKMATIC LEVEL & TEMPERATURE MONITOR/CONTROLLERS Ideal for continuous display and control of the level and/or temperature of liquids in tanks, sumps, etc. with output signals to interface with your application. Examples Constant monitoring of level, temperature or volume of water (or any liquid such as fuel oil) in tank(s), with analogue and digital outputs for BMS, for high and low liquid level and high and low liquid temperature. Outputs also available to switch pumps, valves alarms etc. General Tank lid or wall mounted control panel with either submersible or tank/pipework mounted level and temperature sensors. Optional remote display available for mounting in suitable location up to 1500m away. Data Sheet 402 AQUATANK APT SERIES ONE AND TWO PIECE GRP BREAK TANKS Aquatanks are moulded in one or two piece using GRP materials as approved by the Water Research Centre. Built to BS4994. All tanks and lids are pre-insulated with 25mm CFC-free foam fully encapsulated within the laminates as standard to provide a U value of 0.84 W/m 2 K. Two piece, 50mm and 75mm insulation options are also available. All tanks comply with the Water Regulations (Water Fittings) Regulations 1999 and incorporate a type AB Air Gap and are fitted with a raised float valve chamber with screened mesh slots. All tanks are in light grey to BS ,400 litre sizes available Glass Reinforced Plastic (GRP) 25mm standard Pre-insulation WRAS Approved By-Law 30 Type AB Air Gap (Raised Float Valve Chamber) Data Sheet

11 AQUATANK APT SECTIONAL GRP TANKS Sectional tanks find application whenever access to the tank location is restricted or when large capacities are required. One piece storage tanks only being suitable for capacities of about 6m 3 before handling limitations become dominant. Sectional tanks comprise bolted panels and a metal bracing system depending upon size. They are supplied in a palletised form for installation by our trained erectors in the UK or for self-build for overseas projects. Available in three versions IFB Externally flanged sides with internal flanged base TIF Totally internally flanged EFB Totally externally flanged Heights to 5m Any footprint in 500mm increments Class leading thermal performance Supply and install WRAS Approved Product Data Sheet 501s A POD PACKAGED PLANT ROOMS Tank sizes available from 1,600-10,000 litre nominal storage capacity. The unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water which is accessed via a lid mounted lockable manway. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to outside and do not therefore normally require any additional pipework. The whole unit is mounted and fixed to a fully welded galvanised steel skid which allows offloading and movement on site by fork lift truck. The principle is to provide the unit factory assembled, with the booster set, associated pipework interconnections and electrical equipment as a fully packaged product. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a plug and play unit requiring minimal onsite installation. Data Sheet 509 Call +44 (0)

12 PRESSURISATION UNITS Pressurisation Units for maintaining pressure in sealed heating or chilled systems. MINIPACK BASIC 700mm Heating and chilled water system pressurisation Temperature 3 C to 90 C Fill Pressure Up to 3.5 bar System content Up to 5,000 litres Single pump, wall mounted design Basic Microprocessor Control with safety interlock Data Sheet 226 MINIPACK ENHANCED 700mm Heating and chilled water system pressurisation Temperature 3 C to 90 C Fill Pressure Up to 3.5 bar System content Up to 5,000 litres Twin pump, wall mounted design Enhanced Microprocessor Control with full BMS package Data Sheet

13 AQUAPACK AP SERIES NEW EXTENDED OPTIONS AVAILABLE Heating and chilled water system pressurisation Temperature 3 C to 90 C (120 C with buffer) Fill Pressure Up to 9.0 bar with standard versions Bespoke options available up to 14.0 bar System content Up to 50,000 litres Twin pump, floor or wall mounted BMS enhanced package included 950mm New options Dual system pressurisation Degassing active vacuum (see left) Data Sheet 207 AQUATANK EXPANSION VESSELS Heating and chilled water Temperature 0 C to 90 C Pressure 10.0 bar maximum working Sizes 8 to 500 litres in stock Up to 5000 litres on request Options 16 bar and 25 bar rating Drinking water flow through Data Sheet 403 Call +44 (0)

14 SPILLBACK SB SERIES Heating and chilled water system pressurisation Temperature 3 C to 99 C Fill Pressure Up to 8.0 bar System content Up to 50,000 litres Twin pump, floor mounted BMS enhanced package included Data Sheet 225 SPILLPRESS SP2ET SERIES Heating and chilled water system pressurisation Temperature 3 C to 90 C (120 C with buffer) Fill Pressure Up to 8.0 bar System content Up to 70,000 litres Twin pump, floor mounted Sealed spill vessel BMS enhanced package included Data Sheet 214 AQUASPILL AS SERIES Heating and chilled water system pressurisation Temperature 3 C to 150 C as standard and above, if required Fill Pressure Up to 25.0 bar as standard and above, if required System content Up to 1,000,000 litres as standard, above on request Open spill tank BMS enhanced package included Data Sheet

15 PRESSURISATION UNIT CASE STUDIES THE ROYAL CENTRAL SCHOOL OF SPEECH & DRAMA Location: London, UK Client: The Royal Central School of Speech & Drama Product: Pressurisation Unit Aquatech Pressmain s Pressurisation Unit at The Royal Central School of Speech & Drama has been keeping the students warm for 28 years. Quality and reliability have always been important to Aquatech Pressmain, proved by the fact that the unit still has it s original pump and expansion vessel. An Estate Manager s dream. The unit has benefitted from inspections and maintenance every six months provided by AGM, Aquatronic Group Management Plc, owners of the Aquatech Pressmain brand. UNIVERSITY OF WARWICK Location: Coventry, UK Client: University of Warwick Product: Bespoke Pressurisation Unit The technical team from Aquatech Pressmain were asked to assist the estates team of Warwick University and their consulting engineers Couch Perry Wilkes to overcome a unique issue with pressurising the university campus heating system. The challenge was to pressurise the system utilising two sealed system pressurisation units, in two plant rooms located on opposite sides of the system, something quite unusual, but essential to the university team to provide system redundancy in the event of maintenance down time of either of the two plant rooms. Taking into consideration ordinance differences in the location of the two pressurisation units, each unit was set up with different pressure differentials in the controls systems to balance the system and then commissioned back into service. Call +44 (0)

16 RAINWATER HARVESTING Pumped waste water, ground water and sewage solutions Application Collecting and storing of rainwater above or below ground, for supplying water to toilets, washing machines and irrigation, for domestic and commercial. Available in direct and indirect versions. Duty Range Flows to 2 l/s Head to 6.0 bar Tank Size 1,500 litres to 7,500 litres typical domestic 10,000 litres plus custom designs WRAS approved product Data Sheet 713 CHESTER STORYHOUSE CULTURAL CENTRE Location: Chester, UK Client: Kier Construction Product: Rainwater Pump System This fully integrated cultural centre opened on 11 May 2017 and houses a theatre, cinema and library - a first for Britain. The project included the redevelopment of the 1937 Odeon cinema retaining many of its art deco features. The site had a historic water management problem which due to their knowledge and expertise Aquatech Pressmain were able to solve. They designed and Installed pumps and a large collection tank to hold excess rainwater, allowing the centre to manage the water, releasing it into the main drains when appropriate, preventing any local flooding. Storyhouse is set to welcome a million visitors in its first 12 months and has been nominated for numerous awards. 14

17 WASTE WATER PRODUCTS WASTE WATER Clean and dirty water removal from pits, trenches, cellers, tanks etc. Duties 35m 3 /h flow to 20 metres head Shock resistant plastic & stainless steel IP68 protection 10-30mm solid handling Tandem mechanical seal options Float control options Data Sheet 708 SEWAGE/FOUL WATER Dispose of sewage from collection chambers and concrete pump stations. Duties 150m 3 /m to 20 metres head Cast iron construction with fix options IP68 protection Up to 100mm solid handling Single and double bi-directional seals Float control options Data Sheet 708 PUMP LEVEL CONTROLS For operation of 1 or 2 pumps Single or Three phase AC supply LED clear text display IP65 Polycarbonate housing Programmable start delay Automatic level control by either float switches, pneumatic tube or 4-20 ma external source BMS volt free output terminals Memory logging for last 65 faults Integrated audible and visual alarm Data Sheet 708 Call +44 (0)

18 OTHER AGM SERVICES Aquatech Pressmain products are supported by their network of AGM service engineers distributed throughout England, Scotland and Wales, with two main regional service located in Colchester and Manchester. This means that in the majority of cases our engineers will never be any more than four hours away from attending a breakdown. SERVICE NETWORK AND SUPPORT We place great emphasis on providing technical backup to support our service engineers and in resolving the most demanding operational and technical issues. And we pride ourselves on getting the job done and never leaving a problem unresolved or a customer waiting. This quality of service has made us the number one choice for so many of our customers. All of our service engineers have... Contractor Client National Safety Group Safety Passport CSCS Cards Confined space training (where appropriate) Training in all aspects of pressurisation and water booster systems Training for the examination of pressure systems We are registered with... BSI ISO9001 Quality Assurance BSI ISO14001 Environmental Management B&ES Membership Construction Line CHAS British Safety Council Safe Contractor UVDB Registered 16

19 SCHEDULED MAINTENANCE AGREEMENTS To maximise the efficiency and safe operation of equipment it is essential that regular service be carried out. We can offer a wide variety of pre-planned maintenance services, tailored to meet the needs and budget of any client. One of our dedicated team will advise on the most appropriate agreement to suit your requirements. Benefits of an AGM Maintenance Agreement Access to our 24/7/365 emergency helpline Priority emergency response Reduced call-out rate Access to fully trained technical support team Free on-site asset surveys Statutory Compliance with PSSR SLAs and KPI monitoring Peace of mind WATER HYGIENE SERVICES Under existing government legislation an employer or person in control of a premises has a legal obligation to ensure the safety of staff, visitors and people in the vicinity of their property. One of these duties is to prevent and control the risk of proliferation and exposure to Legionella. Risk Assessments AGM can provide suitably qualified staff to identify the risk of exposure to Legionella within any water system. Remedial work Following a risk assessment, remedial work may be required to bring a water system in line with current legislation. Control Schemes A normal part of our risk assessment process is to recommend a strategy for the regular monitoring and inspection of your water system, enabling you to manage the risk of Legionella proliferation in the future. Call +44 (0)

20 Head Office AGM House, London Road, Copford, Colchester, CO6 1GT Manchester Office Unit 10 Wheel Forge Way, Ashburton Road West, Manchester, M17 1EH To discuss your project please call: Head Office: +44 (0) Manchester: +44 (0) Aquatech Pressmain is an AGM brand. Datasheet No: 301 Issue No: 7 Date: 01/03/18

PED (Pressure Equipment Directive) Compliant BSI Certificates CE & 95658

PED (Pressure Equipment Directive) Compliant BSI Certificates CE & 95658 Although the name AquaTech Pressmain may not be familiar to you, it s likely that we re already a part of your everyday life. With more than seventy years experience, we are market leaders in the supply

More information

COLD WATER STORAGE CONTROL AYLESBURY DELAYED ACTION FLOAT-ACTIVATED VALVES

COLD WATER STORAGE CONTROL AYLESBURY DELAYED ACTION FLOAT-ACTIVATED VALVES COLD WATER STORAGE CONTROL AYLESBURY TM DELAYED ACTION FLOAT-ACTIVATED VALVES Keraflo have manufactured top quality, delayed action float valves in the UK for over 30 years. The Aylesbury TM range is synonymous

More information

COLD WATER STORAGE CONTROL AYLESBURY TM FLOAT VALVE RANGE

COLD WATER STORAGE CONTROL AYLESBURY TM FLOAT VALVE RANGE COLD WATER STORAGE CONTROL AYLESBURY TM FLOAT VALVE RANGE Keraflo have manufactured top quality, delayed action float valves in the UK for over 30 years. The Aylesbury TM range is synonymous with float

More information

Operation and Maintenance manual Issue No: 1 Issue Date: 4th September 2007

Operation and Maintenance manual Issue No: 1 Issue Date: 4th September 2007 Operation and Maintenance manual Document Title: Purewater CWST O&M Issue No: 1 Issue Date: 4th September 2007 This manual is to be used in conjunction with the following products manufactured by Purewater

More information

Water Hygiene Chlorination Water Treatment Legionella Control

Water Hygiene Chlorination Water Treatment Legionella Control www.whs-ltd.com Water Hygiene Chlorination Water Treatment Legionella Control WATER STORAGE TANK DISINFECTION Cleaning and Chlorination Procedure A clean and chlorination has recently been carried out

More information

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

Installation, Operation and Maintenance Instructions Buffer Vessel OM006 Installation, Operation and Maintenance Instructions Buffer Vessel OM006 Calorifiers Heat Exchangers Pressurisation Units Sales Tel: 01457 835700 Sales Fax: 01457 832700 E-mail: sales@gmsthermal.co.uk

More information

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel OM006 Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel The operating and maintenance instructions contained within this package are for standard mild steel buffer vessels

More information

System Pressure Manager Standard & System Pressure Manager Plus

System Pressure Manager Standard & System Pressure Manager Plus System Pressure Manager Standard & System Pressure Manager Plus Installation, Commissioning & Servicing Instructions Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,

More information

Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels

Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels OM003 Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels The operating and maintenance instructions contained within this package are for standard storage vessels

More information

PressVal Pressurisation Units. Packaged Pressurisation Units with expansion vessels for heating systems.

PressVal Pressurisation Units. Packaged Pressurisation Units with expansion vessels for heating systems. PressVal Packaged with expansion s for heating systems. lamco Basepak LEXILLER lamco Basepak LEXILLER POWER AULT MUTE/ RESET SYSTEM OK lamco ON / O lamco Basepak LEXILLER PressVal SM skid mounted units

More information

Expansion Vessels for Potable Installations

Expansion Vessels for Potable Installations 4. Expansion Vessels for Potable Installations Domestic installations lose millions of litres of potable water due to expansion water leaking from the vent and expansion pipe. Flamco s Airfix diaphragm

More information

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

Multiple Pressure Booster Systems With Variable Speed Controller Type BL Multiple Pressure Booster Systems With Variable Speed Controller Type BL General Characteristics - Single or multistage pumps - Horizontal or vertical mounting - Total head 30m ~ 250m - Material construction:

More information

LEGIONELLA MANAGEMENT PROCEDURE

LEGIONELLA MANAGEMENT PROCEDURE LEGIONELLA MANAGEMENT PROCEDURE This procedure sets out the aims and objectives of the school and outlines responsibilities for managing the risk of exposure to legionella. General Statement of Intent

More information

E PGN-11. Part of NTW (O)32 Estates Operations and Maintenance Policy Paul McCabe Head of Estates and Facilities-NTW Solution Ltd

E PGN-11. Part of NTW (O)32 Estates Operations and Maintenance Policy Paul McCabe Head of Estates and Facilities-NTW Solution Ltd Estates Operations and Maintenance Practice Guidance Note Management of Pressure Systems V01 Date Issued Planned Review PGN No: Issue 1 - Nov 2015 Issue 2 Nov 2017 Author / Designation Responsible Officer

More information

Variable Area Flow Meters

Variable Area Flow Meters Variable Area Flow Meters Over sixty years of variable area meter expertise Brooks started designing and manufacturing variable area (VA) meters, also referred to as rotameters, in 1946. Now, with more

More information

Innovative Pressure Testing Equipment

Innovative Pressure Testing Equipment Innovative Pressure Testing Equipment Oil & Gas Subsea Universities Nuclear Materials Science Supporting Industry and Research Worldwide www.kwdesign.co.uk Who are KW Designed Solutions? We are industry

More information

Grundfos GT TANK Keep it safe

Grundfos GT TANK Keep it safe GRUNDFOS GT TANK Grundfos GT TANK Keep it safe Long-life tanks for all needs Grundfos pressure tanks are all ideally suited and approved for use with drinking water. The material used ensures that there

More information

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION OCT2010 STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 020 87833050

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range Models: DS 126 Single Pump / Single System DT 126 Twin Pump / Single System DS 160

More information

Renewables. Tribune HE Unvented Hot Water Cylinders Installation and Maintenance Instructions. Issue 17 July 2012

Renewables. Tribune HE Unvented Hot Water Cylinders Installation and Maintenance Instructions. Issue 17 July 2012 Renewables Tribune HE Unvented Hot Water Cylinders Installation and Maintenance Instructions Issue 17 July 2012 IMPORTANT NOTE TO THE INSTALLER Read these instructions before commencing installation. Unvented

More information

Manual Actuated Boiler Blowdown Valves

Manual Actuated Boiler Blowdown Valves Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure

More information

MEGAFLO Eco. Technical data FOR THE ULTIMATE IN HOT WATER PERFORMANCE AND COMFORT

MEGAFLO Eco. Technical data FOR THE ULTIMATE IN HOT WATER PERFORMANCE AND COMFORT Technical data Technical data COMPONENTS THE FOLLOWING COMPONENTS ARE SUPPLIED AS STANDARD WITH MEGAFLO Eco FACTORY FITTED IMMERSION HEATER(S) AND THERMAL CONTROLS. INDIRECT MODELS: LONG-LIFE SUPERLOY

More information

Specification Catalogue

Specification Catalogue Uniclass SS_55_15_65 CI/SfB (53) Xh Specification Catalogue Contents Keraflo Overview 3 Our Products / Specification Support 4 Keraflo was founded in Aylesbury, Buckinghamshire in 1983. The town gave Keraflo

More information

200A Series ELECTRONIC LEVEL TRANSMITTER

200A Series ELECTRONIC LEVEL TRANSMITTER MARINE - WATER AND PROCESS INDUSTRIES LIQUID LEVEL AND CONTENTS APPLICATIONS HYDROSTATIC OPERATION 200A Series ELECTRONIC LEVEL TRANSMITTER INTRINSICALLY SUBMERSIBLE - SCREWED MARINE SAFE FLANGED - HYGIENIC

More information

Liquid Level Controllers

Liquid Level Controllers Liquid Level Controllers ALL PUMPS LLC-2Y For both pump up and down control. Variable On/Off set points. NDP-15/20/25/32, DP-10/15 & *NDP-40/50/80 LLC-1 Pump up and down versions available. 6 to 12 differential

More information

AUTOMATIC HOSE TEST UNIT, TYPE SPU

AUTOMATIC HOSE TEST UNIT, TYPE SPU VALVES AND FITTINGS UP TO 14,000 BAR TEST AND CONTROL EQUIPMENT H IGH PRESSURE TECHNOLOGY AUTOMATIC HOSE TEST UNIT, TYPE SPU Pressure range from 1 up to 10,000 bar User-friendly touch panel operation HIGH-PRESSURE

More information

Prestige Water Equipment Ltd.

Prestige Water Equipment Ltd. The Prestige range of water softeners complements the range of water pre-treatment products and services. Use of water softening minimises the problems caused by hard water scale such as reduced heat transfer

More information

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03 INSPIRED EF F ICIENCY PRESSURISATION UNITS MAXI P R ESSUR I SAT I O N U NI T S T E CH N I CAL D O CUMEN T A T I O N I SSUE 1 0 /1 7 R e v. 0 1 TABLE OF CONTENTS 1. 2. 3. 4. 5. 6. 7. 8. 9. Technical Data

More information

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward GN 4-7 kw/5.5-10 hp Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward Total capability, total responsibility Right at the heart of your business, Atlas Copco delivers quality compressed air

More information

multi-boost the EPS range of multi-boost water systems Owners Manual Installation Operation Maintenance demand special treatment

multi-boost the EPS range of multi-boost water systems Owners Manual Installation Operation Maintenance demand special treatment multi-boost the EPS range of multi-boost water systems Owners Manual Installation Operation Maintenance demand special treatment Table of Contents Introduction... Health & Safety Health. Safety. Designs

More information

Prestige Water Equipment Ltd.

Prestige Water Equipment Ltd. The Prestige range of water softeners complements the range of water pretreatment products and services. Use of water softening minimises the problems caused by hard water scale such as reduced heat transfer

More information

High Performance BSP Dial Up Pattern Pressure Reducing Valve

High Performance BSP Dial Up Pattern Pressure Reducing Valve See our full range online at: www.vip-ltd.co.uk High Performance BSP Dial Up Pattern Pressure Reducing Valve VIP Product Code 31/0103 FUNCTION Pressure reducing valves are devices which, when installed

More information

Legionella Policy. Policy Ref: PS08. Prepared By. Georgina Kent, Operations Director. Date of Current Review August 2018

Legionella Policy. Policy Ref: PS08. Prepared By. Georgina Kent, Operations Director. Date of Current Review August 2018 Legionella Policy Policy Ref: PS08 Prepared By Georgina Kent, Operations Director Date of Current Review August 2018 Date of Next Review August 2021 Reviewed By PHA Board 1. Introduction 1.1 The aim of

More information

Blowdown vessels Meeting the requirements of HSE PM60

Blowdown vessels Meeting the requirements of HSE PM60 Blowdown vessels Meeting the requirements of HSE PM60 BDV60 blowdown vessels A complete range of equipment for the safe disposal of boiler blowdown Boiler blowdown Steam boilers must be blown down to remove

More information

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This

More information

Pressure & Flame Protection

Pressure & Flame Protection Pressure & Flame Protection Safety & Regulating Valves Safety & Regulating Valves Pressure Reducing Valves - These valves are installed where there is a requirement to reduce the pressure from one level

More information

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN

More information

KSB Delta Compact Type Series Booklet

KSB Delta Compact Type Series Booklet Pressure Booster System KSB Delta Compact Type Series Booklet Legal information/copyright Type Series Booklet KSB Delta Compact All rights reserved. The contents provided herein must neither be distributed,

More information

User Information Sheet 015

User Information Sheet 015 User Information Sheet 015 Formerly LPGA Guidance NO.84 March 2007 Inspection and Maintenance of LPG Pipework at Commercial and Industrial Premises 1. Introduction LPG pipework may, under certain conditions,

More information

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL Company Registered Office: Crown House, Stockport, Cheshire, SK13RB No. 850 0700 67 Registered in England and Wales No. 05058855

More information

SINGLE VALVE WITH LOW-FLOW BYPASS

SINGLE VALVE WITH LOW-FLOW BYPASS CONTROL VALVES Pressure Reducing Valve Sizing Guide Sizing pilot operated reducing valves is not a complicated process. It starts with determining requirements and following these guidelines in valve size

More information

Digester Processes. 1. Raw Sludge Pumping System

Digester Processes. 1. Raw Sludge Pumping System Digester Processes 1. Raw Sludge Pumping System Removes accumulated sludge from the primary clarifiers, pumped through 1 of 2 pipes either 150 or 200mm in diameter (Fig. 1.1). Fig 1.1 Pipes feeding Digesters

More information

MFP14-PPU (Vented) Automatic Packaged Pump Units

MFP14-PPU (Vented) Automatic Packaged Pump Units 681060/2 IM-P681-02 ST Issue 2 MFP14-PPU (ented) Automatic Packaged Pump Units Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Single MFP14 - PPU installation

More information

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Spirax Compact FREME Flash Recovery Energy Management Equipment

Spirax Compact FREME Flash Recovery Energy Management Equipment IM-UK-cFREME UK Issue 1 Spirax Compact FREME Flash Recovery Energy Management Equipment Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4.

More information

Applied Compression s nitrogen generator packages offer users a cost-effective alternative to costly bottled nitrogen.

Applied Compression s nitrogen generator packages offer users a cost-effective alternative to costly bottled nitrogen. APPLICATIONS: Autoclaves Modified Packaging Atmospheres Coffee Packaging Oxidation Control Coil Tubing Units Pharmaceutical Manufacturing Electronic Parts Manufacturing Reflow Ovens Enhanced Oil Recovery

More information

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant Health and Safety Executive Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant Background Accidents involving

More information

SCIENCE LAB UTILITY CONTROLS

SCIENCE LAB UTILITY CONTROLS SCIENCE LAB UTILITY CONTROLS INCORPORATING GAS PRESSURE PROVING GAS PRESSURE PROVING EQUIPMENT - ENGINEERED TO DELIVER EXCEPTIONAL LEVELS OF SAFETY THE MERLIN RANGE DESIGNED FOR EDUCATIONAL LABORATORIES

More information

Centre of Excellence for Subsea Safety

Centre of Excellence for Subsea Safety Centre of Excellence for Subsea Safety Departments nhc training nhc testing nhc consulting nhc emergency Medical Equipment Hyperbaric Welding 07 09 13 15 17 11 Welcome to nhc National Hyperbaric Centre

More information

KSB Delta Compact Type Series Booklet

KSB Delta Compact Type Series Booklet Pressure Booster System KSB Delta Compact Type Series Booklet Legal information/copyright Type Series Booklet KSB Delta Compact All rights reserved. The contents provided herein must neither be distributed,

More information

GUIDE Specialist manufacturer and supplier of water booster sets, pressurisation units, pumps and ancillaries

GUIDE Specialist manufacturer and supplier of water booster sets, pressurisation units, pumps and ancillaries THE WES PRODUCT GUIDE Specialist manufacturer and supplier of water booster sets, pressurisation units, pumps and ancillaries Parkside Road, Kendal, Cumbria LA9 7DU Tel: 01539 724334 Fax: 01539 733734

More information

Pipe-Away Pressure Vacuum Vent /Conservation Vent

Pipe-Away Pressure Vacuum Vent /Conservation Vent R R Pressure Vacuum Vent / End of Line Conservation Vent Flame Arrester with Pressure Vacuum Vent Pipe Away Pressure Vacuum Vent / Conservation Vent Vacuum Relief Vent Pressure Emergency Vent Free Vents

More information

GUIDELINES. Systems. Pressure. Guidelines Acceptance of equipment, establishment of safe operating limits and fitness for service

GUIDELINES. Systems. Pressure. Guidelines Acceptance of equipment, establishment of safe operating limits and fitness for service GUIDELINES Pressure Systems Guidelines Acceptance of equipment, establishment of safe operating limits and fitness for service Document Reference: PSG 16 Issue 04 Dated 13/09/16 The Safety Assessment Federation

More information

Pressure Systems Safety Regulation

Pressure Systems Safety Regulation Pressure Systems Safety Regulation Introduction This document informs Faculty of the key requirements of the UK and Chinese Pressure Systems Safety regulations. The aim of these regulations is to prevent

More information

TANKTRONIC. STANDARD CONFIGURATION Single Tank. ADVANCED CONFIGURATION Multiple Tanks. Twin Tank (common valve) Twin Tank (separate valves) Vent box

TANKTRONIC. STANDARD CONFIGURATION Single Tank. ADVANCED CONFIGURATION Multiple Tanks. Twin Tank (common valve) Twin Tank (separate valves) Vent box TANKTRONIC STANDARD CONFIGURATION Single Tank control unit Twin Tank (common valve) control unit Twin Tank (separate valves) control unit ADVANCED CONFIGURATION Multiple Tanks control unit S-Module Tanktronic

More information

Summary of the MRA LPG Codes of Practice

Summary of the MRA LPG Codes of Practice Summary of the MRA LPG Codes of Practice COP A1 DESIGN and INSTALLATION Code COP A1 deals with above ground installations where LPG is stored under pressure at ambient temperatures in fixed vessels larger

More information

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply 4.1.1 General The primary function of a system for handling fuel oil is to transfer oil from the storage tank to the oil burner at specified conditions

More information

Flexible Engineered Solutions International CALM Buoy Swivels

Flexible Engineered Solutions International CALM Buoy Swivels Flexible Engineered Solutions International CALM Buoy Swivels Merchant Court, North Seaton Industrial Estate, Ashington, Northumberland, NE63 0YH, England Telephone: +44 (0) 1670 524 960 I Fax: +44 (0)

More information

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in

More information

CALEFFI. Ball zone valves. series /03 GB

CALEFFI. Ball zone valves. series /03 GB all zone valves series cert. n ISO / Function Zone valves are used to automatically shut-off the flow of carrier fluid distributed to a system. Specifically: -In central heating systems, they support the

More information

SEMI-SUB AND JACK UP DRILL RIGS SPECIALIST CLEANING SERVICES & EQUIPMENT RENTAL SOLUTIONS

SEMI-SUB AND JACK UP DRILL RIGS SPECIALIST CLEANING SERVICES & EQUIPMENT RENTAL SOLUTIONS SEMI-SUB AND JACK UP DRILL RIGS SPECIALIST CLEANING SERVICES & EQUIPMENT RENTAL SOLUTIONS PONTOON BALLAST / FUEL TANKS DRILL WATER TANKS POTABLE WATER TANKS SPECIALIST CLEANING FUEL OIL DAY TANK & SETTLING

More information

from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010

from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010 from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010 Dewar vessel noun. A container with an evacuated space between two walls, capable of maintaining its contents at a

More information

P-04 Stainless Steel Corrugated Hoses and Metal Bellows Expansion Joints

P-04 Stainless Steel Corrugated Hoses and Metal Bellows Expansion Joints Guideline No.P-04 (201510) P-04 Stainless Steel Corrugated Hoses and Metal Bellows Expansion Joints Issued date: 20 th October 2015 China Classification Society Foreword This Guideline is a part of CCS

More information

Pressure maintenance systems up to 10 MW with pumps

Pressure maintenance systems up to 10 MW with pumps Pressure maintenance system with pumps Transfero T_ Pressure maintenance systems up to 10 MW with pumps Pressurisation & Water Quality alancing & Control Thermostatic Control ENGINEERING ADVANTAGE Pneumatex

More information

Installation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve

Installation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve Installation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve TMV3 / TMV2 Combined Valve C85079 C85081 C85080 C85082 It is important that these guidance notes are read and fully understood

More information

776 Cryogenic Safety Valve

776 Cryogenic Safety Valve 776 Cryogenic Safety Valve INTRODUCTION 776 Cryogenic Safety Valve The effects of exceeding safe pressure levels in an unprotected pressure vessel or system, can have catastrophic effects on both plant

More information

AUTOMATIC GAS MANIFOLDS

AUTOMATIC GAS MANIFOLDS AUTOMATIC GAS MANIFOLDS Phoenix Pipeline Products Limited. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com

More information

Installation Instructions and User Guide

Installation Instructions and User Guide Installation Instructions and User Guide 15mm & 22mm In-Line Thermostatic Mixing Valve-TMV3 Model P402 It is important that these guidance notes are read and fully understood prior to product installation

More information

GUIDELINES. Systems. Pressure

GUIDELINES. Systems. Pressure GUIDELINES Pressure Systems Guidelines Pressure Systems Safety Regulations SI 2000 No 128 Examination Requirements for LPG Systems on Fork Lift Trucks Document Reference: PSG 12 Issue 2.1 Dated 30/01/12

More information

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger OM008 Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger The operating and maintenance instructions contained within this package are for Pacific water/water

More information

SRI Jigger Tubes System

SRI Jigger Tubes System SRI Jigger Tubes System Design, Installation and Commissioning Manual (Abbreviated Version) INDEX This manual details how the SRI Jigger Tubes System can be tailored to suit the needs of a variety of vacuum

More information

SCA Series Inverted Bucket Steam Traps

SCA Series Inverted Bucket Steam Traps 0770050/5 IM-P077-06 ST Issue 5 SCA Series Inverted Bucket Steam Traps Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Commissioning

More information

Electro-Magnetic Flowmeters Electromagnetic Sensor

Electro-Magnetic Flowmeters Electromagnetic Sensor Data Sheet (US) Electro-Magnetic Flowmeters Electromagnetic Sensor MagMaster TM Plus MFF Unrivalled, fully traceable flow performance 0.15% accuracy Operable flow range: 1500:1 ensures more precise revenue

More information

Manifolds & pressure reducing sets

Manifolds & pressure reducing sets Manifolds & pressure reducing sets Automatic Changeover Manifold (Electronic) Providing continuous supply of medical gases Pneumatech Medical Gas Solutions (PMGS) PureGAS Manifolds provide a duty or standby

More information

Valve test benches. Systems overview

Valve test benches. Systems overview Valve test benches Systems overview About us In the past few years WIKA has successfully integrated renowned manufacturers of calibration equipment into the group. With these established brands within

More information

CHECK VALVES FOR CRYOGENIC SERVICE

CHECK VALVES FOR CRYOGENIC SERVICE CHECK VALVES FOR CRYOGENIC SERVICE www.checkvalves.co.uk Performing where it matters Goodwin International is globally approved for its design, manufacture and supply of Dual Plate Check Valves and Non-Slam

More information

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps Airfix D-E 6442.eps GB Installation and operating instructions 1999, Exclusion of liability All operation and maintenance related technical information, data and instructions contained in these installation

More information

JET Mini Mechanical Pressurisation Equipment

JET Mini Mechanical Pressurisation Equipment JET Mini Mechanical Pressurisation Equipment Mini Models (130HL, 230HL) Operation & Maintenance Manual Rev 2.2 We reserve the right to change designs and technical specifications of our products. Rev 2.2

More information

Legionella Guidance. Property managers specialising in residential, apartment, block and estate management

Legionella Guidance. Property managers specialising in residential, apartment, block and estate management Legionella Guidance Legionnaires disease is a potentially fatal lung infection - pneumonia, that is caused by the legionella bacteria. It can be caught by breathing in small droplets of contaminated water.

More information

Air Eliminator Series

Air Eliminator Series Air Eliminator Series Air Separation Equipment FILE NO: 9-1 DATE: August 2010 SUPERSEDES: 9-1 DATE: January 2009 Air Eliminator Series Air Separation Equipment Modern sealed heating and cooling systems

More information

SF 6 Product Guide. Gas Analysis Instruments and Accessories

SF 6 Product Guide. Gas Analysis Instruments and Accessories SF 6 Product Guide Gas Analysis Instruments and Accessories Cambridge Sensotec Ltd specialises in the design and manufacture of gas analysis equipment under the Rapidox brand name. Based in the UK, the

More information

BRITISH STANDARD BS 341-4: Transportable gas container valves. Part 4: Pressure relief devices ICS

BRITISH STANDARD BS 341-4: Transportable gas container valves. Part 4: Pressure relief devices ICS BRITISH STANDARD BS 341-4:2004 Transportable gas container valves Part 4: Pressure relief devices ICS 23.060.40 This British Standard, having been prepared under the direction of the Standards Policy and

More information

BERMAD Waterworks. Combination Air Valve. Air Valves Series. Typical Applications. Features & Benefits. Additional Features.

BERMAD Waterworks. Combination Air Valve. Air Valves Series. Typical Applications. Features & Benefits. Additional Features. BERMA Waterworks Combination Air Valve Model C7 BERMA C7 is a high quality combination air valve for a variety of water networks and operating conditions. It evacuates air during pipeline filling, allows

More information

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring. Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions

More information

DUAL-VORTEX SEPARATOR. Inspection and Maintenance Guide

DUAL-VORTEX SEPARATOR. Inspection and Maintenance Guide DUAL-VORTEX SEPARATOR Inspection and Maintenance Guide Description The Dual-Vortex Separator (DVS) is a hydrodynamic stormwater treatment device used to remove pollutants from urban runoff. Impervious

More information

Selecting the right pressure sensor for your application

Selecting the right pressure sensor for your application Selecting the right pressure sensor for your application This guide from Acal BFi details the key factors that you must consider when selecting a pressure sensor for your application. Selecting the best

More information

BCGA GUIDANCE NOTE 17

BCGA GUIDANCE NOTE 17 BCGA GUIDANCE NOTE 17 BCGA POLICY AND GUIDANCE FOR THE SAFE FILLING OF THIRD-PARTY OWNED AND / OR MAINTAINED TANKS Revision 2: 2013 BCGA GUIDANCE NOTE 17 BCGA POLICY AND GUIDANCE FOR THE SAFE FILLING OF

More information

AutoChanger Installation & User Guide Issue 2

AutoChanger Installation & User Guide Issue 2 1 INDEX Page 1. Introduction... 3 2. AutoChanger Components Guide 4 3. Installation. 5-11 a) Installation Guidelines.. 5 b) Installation Retrofit... 6-11 c) Installation New... 11 4. AutoChanger User Guide

More information

SPIROVENT VACUUM DEGASSERS

SPIROVENT VACUUM DEGASSERS SPIROVENT VACUUM DEGASSERS S P I R O V E N T A I R S U P E R I O R FLUID AND GAS There are always a certain amount of gasses in a fluid, dependent on pressure and temperature. The British physicist William

More information

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz GRUNDFOS DATA BOOKLET Complete pressure boosting systems 5/6 z Contents Product data Performance range 3 Operating conditions Inlet pressure Type key Product range 5 Construction 5 Installation 5 Mechanical

More information

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series of the OCV control valves.

More information

Water Solenoids Safety Valves Air. Meters. Butterfly Ball Gate Globe Strainers Pressure Gauges Thermometers

Water Solenoids Safety Valves Air. Meters. Butterfly Ball Gate Globe Strainers Pressure Gauges Thermometers Water Solenoids Safety Valves Air Valves Meters Butterfly Ball Gate Globe Strainers Pressure Gauges Thermometers Pneumatics Steam Traps Fire Hydrants Boiler Valves Water Metering Systems By combining high

More information

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING SPECIFICATIONS DIMENSIONS In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series

More information

Installation Instructions / Operating & Maintenance Manual Midi-Fill Digital Pressurisation Unit Models MFD15 & MFD22

Installation Instructions / Operating & Maintenance Manual Midi-Fill Digital Pressurisation Unit Models MFD15 & MFD22 Arrow Valves Ltd Installation Instructions / Operating & Maintenance Manual Midi-Fill Digital Pressurisation Unit Models MFD15 & MFD22 Tel 01442 823 123 Fax 01442 823 234 www.arrowvalves.co.uk Model shown

More information

The Next Generation for Level Control. By Ryan Spooner, Singer Valve

The Next Generation for Level Control. By Ryan Spooner, Singer Valve The Next Generation for Level Control By Ryan Spooner, Singer Valve The Next Generation for Level Control Water is an essential resource to everyday life and therefore having a way to store and distribute

More information

Introduction. Legal Duties. Risk Assessment

Introduction. Legal Duties. Risk Assessment All Hampstead Hill School Policies are always to be read and considered in conjunction with Equal Opportunities, Race Equality and Inclusion Policies. This Policy of Hampstead Hill School applies to all

More information

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL

More information

Trifecta Systems. Cryogenic Equipment for High Performance Gas Supply. Trifecta Product Catalog

Trifecta Systems. Cryogenic Equipment for High Performance Gas Supply. Trifecta Product Catalog Trifecta Systems Cryogenic Equipment for High Performance Gas Supply C O N S U LT I N G S Y S T E M D E S I G N I N S TA L L AT I O N C O M M I S S I O N I N G T R A I N I N G Trifecta Product Catalog

More information

On-Off switch. Selectable manual control for commissioning. Remote start input for control via an irrigation controller, or external sensor.

On-Off switch. Selectable manual control for commissioning. Remote start input for control via an irrigation controller, or external sensor. SPEEDMAN VARIABLE SPEED PUMP SET VARIABLE SPEED PUMP SET PRODUCT DESCRIPTION Variable speed / constant pressure system consisting of a Davey VM vertical multistage pump with Speedman controller, VSD unit,

More information