MAGANO WEITAI. MAGANO machinery manufacturing. professional manufacture booster regulator. Air amplifier/booster. air booster gas booster
|
|
- Marjorie Marshall
- 5 years ago
- Views:
Transcription
1 air booster gas booster MAGANO air driven hydraulic booster pressure-proof testing station WEITAI high pressure valves special cylinders professional manufacture booster regulator pneumatic MAGANO Ningbo Magano Machinery Manufacturing Co,.Ltd. Add 87 Zhongxing East Road,Xikou,Fenghua, Ningbo, China TEL FAX Web Air amplifier/booster
2 Booster regulator introduction Booster regulator, also called "pressure cylinder" or " air amplifiers ", the work principle is the use of a plurality of cylinders to pressure each other. The pressure on each side of the piston is different because of the unequal area, the high pressure forces the piston to move in order to balance the pressure, then the lower pressure gas will be compressed, making it higher pressure gas. Produsts According to the different media of operating pressure, it can be divided into kinds of air booster gas booster and hiph-pressure pump. Except for pressuring compressed air, booster regulator can pressurize some special gas or liquid making the pressure to a target value to achieve the purpose. Magano air boosters are designed to boost plant air pressure or increase the supply air pressure at work stations and pneumatically operated machinery when the available working pressure is insufficient. Air operated tools become more efficient when coupled with air amplifiers. These boosters are capable of generating pressures from 30 psi to,350 psi. Air boosters do not need electrical power, since they use the same compressed air source for both driving and amplifying. This ensures quick installation and cost effective operation.air boosters can be controlled to automatically stop once the desired end pressure has been reached. The boosters will restart when a drop of only 1% from the stall pressure has been detected. Single stage - single acting and single stage - double acting air boosters are available to satisfy most pressure and flow demands. boosters are ideal for intermittent pressure requirements. Except for the air booster, we can also offer you a choice between standard gas booster high-pressure booster pumps or customised solution
3 Air booster regulator Air booster regulator Air booster regulator( 1:) Air booster regulator Pressure ratio Max flow Tank capacity 63-1: - 1: - 1: pressure: IN=OUT=0.5Mpa 00L/min 0L/min 100L/min MSA63- MSA- Pressure Pressure-time graph MSA 63 I Bore Size Φ63 Φ Φ pressure ratio 1: OR 1: Fitting Blank:No Tank I:Tank() Sheet 1 Specification Inlet pressure Pressure ratio Out flow Dimensions 0.~0.8MPa 1: Sheet 1 Page 3 1: Sheet Page Air booster regulator( 1:) Time(S) Advantage 1. Easy to use : the booster regulator,when connected to type air supply line, increases main line pressure up to two or four times; air pilot operatd, Keep the pressure constant.. Afe to operate :working without any electrical inputs, can be used in flammable gas or liquid sites, saves energy and money. 3. Simple to repair : the design of an external check valve, and easy maintenance.. Low for cost :use booster regulator on branches where higher pressure is needed, Compared with the construction of high-pressure gas stations, more energy-efficient and greener. Application 1. Pressure-proof testing for valves, fittings, pressure vessel, and modification of the gas source in processing cente.. Some equipment that requires higher pressure than that of plant lines. 3. Protect downstream equipment from pressure fluctuations when the plant main gas line pressure drops,and can not guarantee a minimum pressure for pneumatic devices. A compact drive unit,i.e. small cylinder is required, increase the power of an actuator without changing to a larger cylinder. 5. Increase the effective hydroulic pressure of the Air Hydro Unit. 6. High pressure air is required without using electric power. Sheet Pressure Pressure ratio Max flow Tank capacity - - 1: 1: 00L/min 0L/min pressure: IN=OUT=0.5Mpa Pressure-time graph Time(S) 1
4 Air booster regulator Air booster regulator Dimensions(1:) Dimensions(1:) Inlet Inlet Outlet Outlet MSA63- MSA- MSA- A B C D E A B C D E F G -H I J K Ph Pd MSA M MSA M _ Φ1.5(00*110) _ Φ1.5(00*110) 1 MSA63--I A B C MSA--I A B C D 5 MSA--I MSA--I MSA--I
5 High-pressure pump MVA Bore size Pressure ratio Max.flow Φ Φ Φ Φ Φ00 Advantage 1. easy-to-install and low-maintenance units. Only connections to air supply as well as suction and pressure lines are required.. Pressure regulation via manual pressure control units or pneumatically triggered valves. 3.Substitution of leakages by automatic additional delivery of liquid from the pump. Application 1. Hydrostatic Testing for valves, tanks, pressure vessels, pressure switches, hoses, pipes and tubing, pressure gauges, cylinders, transducers, well casings, gas bottles and air craft components.. Burst and Cycle fatigue testing of above components. 3. Pressurization of pressure vessels for testing various components.. Calibration of pressure gauges and transducers. 5. Leak Testing. High-pressure pump for testing Advantage 1.Increase water pressure to 0~Mpa with driving-pressure air at 0.~0.8Mpa..Hydrostatic testing for pressure gauges,compared with the construction of high- pressure hydraulic station, more energy-efficient and greener. High-pressure pump MVA 液压表高压测试 MVA Bore Times Stroke Out-flow Outlet-pressure Inlet size Outlet size Medium Error margin mm 10ml 73ml 7ml 188ml 10ml 73ml 7ml ml 188ml 10ml 73ml 7ml 67ml ml 188ml 10ml 73ml 7ml 115ml 30ml Mode Bore Time Max.out-flow 63--A/E --A/E --A/E --A/E --A/E -6-A/E --A/E --A/E -6-A/E -A/E ml/round 1ml/round 1ml/round 67ml/round 65ml/round 5ml/round 31ml/round 3ml/round 81ml/round 8ml/round 3.7Mpa 6.1Mpa.6Mpa 3.7Mpa 5.8Mpa.6Mpa 15Mpa 3.7Mpa 5.8Mpa.1Mpa 15Mpa 3.Mpa 3.8Mpa 6Mpa.6Mpa 15Mpa.5Mpa 38.Mpa 30.6Mpa 60Mpa 1.Mpa 1.Mpa.Mpa 1.Mpa.Mpa 3.6Mpa 5.Mpa.Mpa 3.6Mpa 5.Mpa High-pressure pump M1*1.5 Liquid without corrosive Air, Inert gas 5% Outlet-pressure Inlet size Outlet size Medium Error margin 5% 1 :Outlet pressure:@ inlet pressure=0. 6Mpa 5 6
6 Direct-pressurre booster cylinder Ordering code Sequence valve High pressure series Pre-running booster cylinder MGN-A 05 1T : boosting stroke: outlet force: MGN-A Characters 05:5mm 10:10mm 15:15mm 0:0mm 1T 3T 5T 10T 0T 1 the same high outlet pressure of hydraulic cylinder with the whole stroke. the range of stroke is 5-0mm, saving space and easy installation compared with hydraulic station. 3 used for mental atamping,riverting electronic components and squeezing die and forn,as well as other working environment without high requirement for frequency. oil recommend: ISO VG3 ; ISO VG68. High pressure reducing valve P A Nominal Diameter(mm) Internal Thread Cperating Pressure(Mpa) Ambient Temperature MSH-08 MSH ~0.85MPa -10~50 Ball vibrator Turbine vibrator MGN-B T 1 the whole stroke can be divided into pre-running stroke with normal outlet pressure of gas cylinder and boosting stroke with high outlet pressure. the stroke range of this model 10-00mm pre-running stroke and 5-0mm boosting stroke. 3 oil recommend: ISO VG3 ; ISO VG68. K Ordering code : MGN-A Characters Ordering code Characters Ordering code whole stroke: 50:50mm :mm 150: 00:00mm 8(10,13,,0,5,30,36) boosting stroke: 05:5mm 10:10mm 15:15mm 0:0mm outlet force: 1T 3T 5T 10T 0T 1 Small volume,less malfunction,easy installation and maintenance. Quick stop or start,applies to manual or automatic systems. 3 Vibratory force,vibratory frequency and amplitude of vibration can be randomly adjusted. This equipment has been widely used and is suitable for the fatigue test of parts or structural members ; In addition, it can be used in the whipping and ramming of hopper, line-shape or bowl-shape feeder,sieve and filter screen,vibrating table and agitating equipment.it can also be used in apoplications such as stowing machine, coating unit, counter, feeder, conveyor, dehydrating separation and particle suspensio. R 50(65,,,10) Applications: R-series pneumatic roller high-frequency vibrator offers a new solution for transportation of fine materials.frequency can be controlled through adjusting air presure due to pneumatic operating characteristic.(mainly used in: empty of hopper, motivation of small particles, ramming of plastic and cement in moulds.) High pressure water segregator Two-position five-way soleniod vavle MD510 MD510S Highest Working Pressure Pressure Regulating Range Inlet Joint Pipe Thread Outlet Joint Pipe Thread.0MPa 0.1~3.5MPa Operating Temperature -5~50 Highest Working Pressure Inlet Joint Pipe Thread Outlet Joint Pipe Thread MD510 fluid medium: air ambinent temperature:-5~ MD515S for higher temperature rated voltage:ac0v 110V 36V DCV 1V Internal thread: QTYH-08 QSLH MPa Operating Temperature -5~50 QTYH-15 QSLH
7 Two-position two-way soleniod vavle High pressure series Booster station M10 M10BS MD10 MD10BS Two-position three-way soleniod vavle M10B fluid medium:air ambinent temperature:-5~ M10BS for higher temperature rated voltage:ac0v 110V 36V DCV 1V internal thread: MD10B fluid medium:air water oil ambinent temperature:-5~ MD10BS for higher temperature rated voltage:ac0v 110V 36V DCV 1V internal thread: (MVT) Driving medium:compressed air Operating medium: compressed air,inert gas,liquid and so on. Control:air control;air control and electronic control Application:output high pressure gas, liquid for test 系列 MVT MGP Bore Times Max.out flow Out-pressure Inlet size Outlet size Medium Error margin --A/E --A/E --A/E --A/E -6-A/E --A/E --A/E -6-A/E --A/E -6-A/E -10-A/E --A/E -6-A/E m³/min 0.m³/min 1.m³/min 1.7m³/min 1.5m³/min 1.m³/min.m³/min.5m³/min.1m³/min output oil 10ml/R 73ml/R 7ml/R 188ml/R 1.6MPa.MPa 1.6MPa.MPa 3.6MPa 5.MPa.MPa 3.6MPa 5.MPa 3.7MPa 6.1MPa.6MPa 3.7MPa Air, Inert gas 5% MD310 MD310S MD310 fluid medium:air water oil ambinent temperature:-5~ MD310S for higher temperature rated voltage:ac0v 110V 36V DCV 1V internal thread: (MGP) MVT MLP --A/E --A/E -5-A/E -6-A/E --A/E -15-A/E -5-A/E -3-A/E ml/R 73ml/R 7ml/R ml/r 188ml/R 10ml/R 73ml/R 7ml/R 5.8MPa.6MPa 15MPa 3.7MPa 5.8MPa.1MPa 15MPa 3.MPa Liquid without corrosive 5% -6-A/E 6. 67ml/R 3.8MPa M310B M310BS M310B fluid medium:air ambinent temperature:-5~ M310BS for higher temperature rated voltage:ac0v 110V 36V DCV 1V internal thread: (MLP) -10-A/E --A/E -5-A/E -0-A/E -6-A/E A/E ml/r 188ml/R 10ml/R 73ml/R 7ml/R 115ml/R 6MPa.6MPa 15MPa.5MPa 38.MPa 30.6MPa 10
8 Air-hydraulic Damping Cylinder W Series Solenoid Valves Zero oil loss: both pneumatic and hydraulic advantage Smooth and stable speed regulation; Desired speed of advance Adjusted easily with all the stroke. A P W 15 AC0V Specification Code Joint Thread Voltage MQY 50 C Vibrator Cylinder Bore Size Φ63 Φ Φ Stroke Anywhere constant power and stable speed are needed, such as lathe modification,cutting feed,drill... 1.Install easily through fixing the front on the vibration-required equipment and connect the air supply.high vibrating frequency and vibrating force C:tandem B:parallel 3.Widely used in fields such as mechanical,building material and package industries M-ZG 63 Bore Size Φ63 Φ Φ W-06 W-08 W-10 W-15 W-0 W-5 W-35 W-0 W-50 Material of valve body Working medium Type Action model Nominal diameter Joint thread Operating pressure Operating temperature Operating voltage range Normal power Check Valve P Throttle Check Valve A Nominal diameter Operating pressure Joint thread Operating temperature Brass Air,Water,Oil Normally Closed Pilot.5mm mm 0mm 5mm 35mm 0mm 50mm G1/8 G3/ G1 G1 1/ G1 1/ G/ Water/Oil (0~0.5MPa) -5~ ±10% AC18VA DCW Air(0~0.7MPa) KA-06 KA-08 KA-10 KA-15 KA-0 KA-5 KA-3 KA-0 KA ~0.85MPa G1/8 G/1 G3/ G1 G1 1/ G1 1/ G Bore size Operating pressure Operating temperature When pressure is 0.6Mpa Max. vibrating frequency When pressure is 0.6Mpa Max. vibrating force P A KLA-06 KLA-08 KLA-10 KLA-15 KLA-0 KLA-5 KLA-3 KLA-0 KLA Hz 5000N Nominal diameter ~0.6Mpa -5~+ 0Hz 6500N Operating pressure Joint thread 0.05~0.5MPa G1/8 G/1 G3/ G1 G1 1/ G1 1/ G 0Hz 00N Operating temperature
Air Amplifiers & SYSTEMS
Air Amplifiers & SYSTEMS We Accept VISA, MasterCard and American Express Air Amplifiers Point-of-Use Air Solutions Maximator air amplifiers are designed to boost plant air pressure or increase the supply
More informationThe Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times
Tseries Series AB AB Air Air Boosters Boosters The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times.01/1 MANIFOLD MOUNTED VALVES FOR EASY SERVICING
More informationAIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express
AIR DRIVEN Gas Boosters & SYSTEMS Accepting VISA, MasterCard and American Express Gas Boosters AIR DRIVEN FROM 30 PSI TO 21,750 PSI MAXIMATOR Maximator gas boosters are an excellent alternative to high
More informationComponents for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.
Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using
More informationAIR DRIVEN LIQUID PUMPS AIR DRIVEN AIR AMPLIFIERS AIR DRIVEN GAS BOOSTERS HIGH PRESSURE VALVES, FITTINGS AND TUBING TEST AND CALIBRATION EQUIPMENT
AIR DRIVEN LIQUID PUMPS AIR DRIVEN AIR AMPLIFIERS AIR DRIVEN GAS BOOSTERS HIGH PRESSURE VALVES, FITTINGS AND TUBING TEST AND CALIBRATION EQUIPMENT MAXIMATOR GmbH MAXIMATOR is one of the world leading manufacturers
More informationhydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI
hydro-pac, inc. LX-SERIES Low-Pressure Gas Compressors 1500 to 6000 PSI hydro-pac, inc. LX-SERIES Features Hydro-Pac LX-SERIES Gas Compressors feature: Oil-free non lubricated gas pistons and cylinders
More informationPressure on Demand. Air Pressure Amplifiers
Pressure on Demand Air Pressure Amplifiers Introduction Haskel air pressure amplifiers offer the most comprehensive range in the industry combining simple principles of operation with rugged construction
More informationFLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:
FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed for outcome
More informationMax operation pressure 6kg/cm 2. Boost pressure rate Air pressure supply 5kg/cm Hydraulic fluid expelled l/min
ADB Air Pump. Single Circuit Air Drive Booster Pmax:6kg/cm A ISO B P T Product Introduction The booster pump is driven by air to output hydraulic pressure for apower source for hydraulic cylinder. Its
More informationUnit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 9 ACCUMULATORS The material needed for outcome 2 is very extensive so there are
More informationStandard Operating and Maintenance Instructions for Pumping System Model PS-150
Standard Operating and Maintenance Instructions for Pumping System Model PS-150 High Pressure Equipment Company, LLC 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075
More informationAir Operated Hydraulic Pumping Systems to 50,000 psi
High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air
More informationPilot Check Valve: Metal Body Type
INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not
More informationFLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:
FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed
More informationHi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:
1.0 Inspection of the product upon receipt: On receipt of the product, visually inspect the item for any evidence of shipping damage. Please note shipping damage is not covered by warranty. If shipping
More informationOWNER S TECHNICAL MANUAL
EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids,
More informationLECTURE 20 FLOW CONTROL VAVLES SELF EVALUATION QUESTIONS AND ANSWERS
LECTURE 20 FLOW CONTROL VAVLES SELF EVALUATION QUESTIONS AND ANSWERS 1: A cylinder has to exert a forward thrust of 150 kn and a reverse thrust of 15 kn. The effects of using various methods of regulating
More informationSeries IRV1000/2000/3000
CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one
More informationInflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer
Inflatable Packer Single & Double Single & Double Packer Dimension Wireline Packer Water Testing Packer (WTP) Packer Packer Working Pressure & Depth Chart Packer Water Hand Pump Packer Air Driven Pump
More informationSRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic
Pharmaceutical SRL Series Oil-less Scroll Air Compressors Research & Development Food & Beverage Chemical Electronic Hitachi Industrial Equipment Product Brochure Hitachi SRL Series scroll compressors
More informationVACUUM REGULATORS CONTENTS
CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate
More informationHydraulic Reliability & Preventive Maintenance Report
Hydraulic Reliability & Preventive Maintenance Report The following is a report of the test, procedures and recommendations for the in-plant press. This information was recorded on May 10 th and 11 th,
More informationHigh precision dispensing valve that is an uncompromising response to the need for sophisticated dispensing equipment
Fluid dose dispensing valve High precision dispensing valve that is an uncompromising response to the need for sophisticated dispensing equipment Provides the high productivity, stability, reliability,
More informationKIT. Small Automatic Water Boosters KIT MODELS
KIT Small Automatic Water Boosters The electronic controller KIT orders the automatic start and stop of the water pump when opening or closing any tap or valve in the installation. There are four main
More informationOPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP
This operating instructions contains safety information that if ignored can endanger life or result in serious injury. They are indicated by this icon. Use of this pump with radioactive chemicals is forbidden!
More informationLeak free Pipe Rupture Valve for Excavators
Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................
More informationHANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:
HANDBOOK Squeeze Off Unit SOU 400 Please refer any queries to: Hy Ram Engineering Co Ltd Pelham Street Mansfield Nottinghamshire NG18 2EY Telephone No: (01623) 422982 Please note all queries should state
More informationALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential
More informationPump Relief, Pressure Tank/
CIRCUIT VALVE ( PRIMARY PRESSURE REGULATING VALVE ) (for Water Air or Oil) Pump Relief, Pressure Tank/ Piping etc. High-performance relief valve that can respond to load change, relieve excessive pressure,
More informationValve test benches. Systems overview
Valve test benches Systems overview About us In the past few years WIKA has successfully integrated renowned manufacturers of calibration equipment into the group. With these established brands within
More informationLevel MEASUREMENT 1/2016
Level MEASUREMENT 1/2016 AGENDA 2 A. Introduction B. Float method C. Displacer method D. Hydrostatic pressure method E. Capacitance method G. Ultrasonic method H. Radar method I. Laser method J. Level
More informationP-04 Stainless Steel Corrugated Hoses and Metal Bellows Expansion Joints
Guideline No.P-04 (201510) P-04 Stainless Steel Corrugated Hoses and Metal Bellows Expansion Joints Issued date: 20 th October 2015 China Classification Society Foreword This Guideline is a part of CCS
More informationModel 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual
10-12 Steel Pipe Squeezer Sch. 40 & Sch. 80 Operations Manual 1.0 Introduction This manual is issued as a basic operation manual covering the Regent Model 7989T, Pipe Squeezer and Pump as manufactured
More informationStandard Operating and Maintenance Instructions for Pumping System Model PS-90
Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075
More informationThe Discussion of this exercise covers the following points:
Exercise 5-3 Wet Reference Leg EXERCISE OBJECTIVE Learn to measure the level in a vessel using a wet reference leg. DISCUSSION OUTLINE The Discussion of this exercise covers the following points: Measuring
More informationGuideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society
Guideline No.M-05(201510) M-05 AIR COMPRESSOR Issued date: 20 October 2015 China Classification Society Foreword This Guideline constitutes the CCS rules, and establishes the applicable technical requirements
More informationAir preparation units
Overview Description Page Characteristics Dimensions Order instructions Type overview unit three-piece 44, 45, 48 52 6 unit two piece 44, 45, 48 52 6 Filter-regulator 44, 45, 48 53 6 Filter-water-separator
More informationOPERATION MANUAL NTF-60 Plus
OPERATION MANUAL NTF-60 Plus Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81264-00 (Rev A)
More informationLocator Locator-D-Lux Air-Saver G1 Air-Saver G2
170663_air_saving_products 17-02-2011 16:42 Pagina 1 Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 AIR SAVING PRODUCTS 170663_air_saving_products 17-02-2011 16:42 Pagina 2 170663_air_saving_products
More informationTECHNICAL DATA. Q = C v P S
Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationAir Saving Valve. Pressure Valve Flow Valve
Air Saving Valve Series Series Pressure Valve Flow Valve % reduction in air consumption Cuts air consumption by operating the return stroke at a reduced pressure. valve Pressure Air consumption reduction
More informationExercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.
Exercise 5-2 Bubblers EXERCISE OBJECTIVE Learn to measure the level in a vessel using a bubbler. DISCUSSION OUTLINE The Discussion of this exercise covers the following points: Bubblers How to measure
More informationMINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS
MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 010 N 89 KNDC N 811 KNE N 814 KNE Concept The mini diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge,
More informationOil connector 3/8NPT. usable oil Air inlet pressure max. operating Air consumtion. oil capacity capacity min. max.
44 97 ir hydraulic pump 9 Operating pressure max. 2 bar/7 bar Conversion ratio :3, : Compact irhydraulicpump for single acting hydraulic tools. This air hydraulic pump can activate a higher number of clamping
More informationOperation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER
Operation Manual - PN 0017946001 A MENSOR MODEL 73 SHOP AIR BOOSTER Mensor Model 73 Shop Air Booster System (750 psi Version) April 23, 2012 Trademarks / Copyright Mensor is a registered trademark of Mensor
More informationMultiple Pressure Booster Systems With Variable Speed Controller Type BL
Multiple Pressure Booster Systems With Variable Speed Controller Type BL General Characteristics - Single or multistage pumps - Horizontal or vertical mounting - Total head 30m ~ 250m - Material construction:
More informationSolenoid valves VZWF, force pilot operated
Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is
More informationValvex Valves for Mining Applications
Valvex Valves for Mining pplications roven technology The Electronic Drive Systems product group at Voith Turbo GmbH & Co. KG develops and produces explosion-proof Valvex solenoid valves and valve assemblies.
More informationGas Boosters & Systems
DRIVEN Gas Boosters & Systems SINGLE ACTING - SINGLE STAGE PRESSURES UP TO 10,875 psi DOUBLE ACTING- SINGLE STAGE PRESSURES UP TO 21,750 psi TWO STAGE PRESSURES UP TO 21,750 psi DOUBLE HEAD - SINGLE AND
More informationBIMBAR INFLATABLE PACKERS AND ACCESSORIES
BIMBAR INFLATABLE PACKERS AND ACCESSORIES Geopro supplies a complete range of inflatable packers in nine different diameters from 28 up to 170mm. All our packers made of BIMBAR rubber technology are reinforced
More informationNGN Series nitrogen generator
NGN Series 8-64 nitrogen generator Applications how it works RK series 5-40 F Blanketing of Chemicals and Pharmaceuticals Gas Assisted Injection Moulding (GAIM) Laser Cutting Food Heat Treament of Ferrous
More informationAUTOMATIC HOSE TEST UNIT, TYPE SPU
VALVES AND FITTINGS UP TO 14,000 BAR TEST AND CONTROL EQUIPMENT H IGH PRESSURE TECHNOLOGY AUTOMATIC HOSE TEST UNIT, TYPE SPU Pressure range from 1 up to 10,000 bar User-friendly touch panel operation HIGH-PRESSURE
More informationHumiSys HF High Flow RH Generator
HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously
More informationNew Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A
Air Consumption 70% Down New Product Precision Regulator Air Saving Type RPE Series PRECISION REGULATOR RPE SERIES Large Air Saving CC-1072A Air Consumption 70% Down. New Type Eco-friendly Precision Regulator
More informationAir Saving Valve. Series ASQ. Series ASR. Pressure Valve. Flow valve TMH ASD AS AS-FG AS-FP AS-FM ASP ASN AQ ASV AK VCHC ASS. r r AS-FE KE 10 0.
Air Saving Valve Series R Pressure Valve Series Q Flow Valve P r.9.7 2..3.1 D -FE KE -FG -FP -FM.1.2.2.3 pressure (MPa) -D -T P ow valve Fl N AQ V e n by o i t p nsum n stroke o c r i r a Cuts g the retu
More informationPlant, components and devices for very high and high pressures (7000 bar and over)
Plant, components and devices for very high and high pressures (7000 bar and over) HIGH PRESSURE GAS BOOSTER INTRODUCTION Multi-coupling system gas booster operate on the simple but efficient principle
More informationINSTALLATION & MAINTENANCE INSTRUCTIONS
DESCRIPTION / IDENTIFICATION The QBX series valve uses Proportion-Air closed loop technology for Pressure control. It gives an output pressure proportional to an electrical command signal input. The QB1X
More informationMaximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications
Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range
More informationTEST BENCH FOR SAFETY VALVES
TEST BENCH FOR SAFETY VALVES 1) Hydro panel : This Panel possesses This Bench Contains One Panel and One Reservoir. 1 No. Monobloc Version : Single Phase AC, 50 Hz Type of Duty :S1 (Continuous) Class of
More informationSeries VBA1110 to 4200
Booster Regulator Series 0 to 4200 Specifications increase ratio Max. supply pressure Set pressure range Ambient and fluid temperature Lubrication Installation adjustable mechanism 0-02 400-04 Handle operated
More informationRelated Products: Auto Drain Valve. Model/Specifications. Model
Related Products: Auto Drain Valve /600 Drainage is automatically discharged in a reliable manner, without requiring human operators. Highly resistant to dust and corrosion, operates reliably, and a bowl
More informationLeak-Free Load-Control Valve SAE ½ psi flange
Leak-Free Load-Control Valve SE ½ - 6000 psi flange Q max = 150 l/min [40 gpm], p max = 420 bar [6000 psi] leak-proof, two-stage hydraulic, SE-flange design 12--S... 1 Description Two-stage load-control
More informationOperating Manual. R280 Pressure regulator made of brass. 1. Intended Use
Pressure regulator made of brass Operating Manual 1. Intended Use Line or outlet pressure regulators- /reducer for Air, gases and liquids which is designed to effect reduction to a downstream pressure
More informationKey Features & Advantages of JEHA MK IV (5,000 PSI Hydraulic Test Stands)
Key Features & Advantages of JEHA MK IV (5,000 PSI Hydraulic Test Stands) The key reasons why MRO Facility now requires 5,000 PSI Hydraulic Test Stand are as follows: 1) New generation commercial aircraft
More information1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type
Flow Control Valve Series LVM.. high flow rates (8 l/min) flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports proportional flow-sharing
More informationOPERATION MANUAL NTF-15
OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE
More informationVACCUPERM Vacuum chlorine gas dosing systems
VACCUPERM Vacuum chlorine gas dosing systems Vaccuperm, precise and safe dosing. www.clorep.es VACCUPERM INTRODUCTION Vaccuperm provides a proven and reliable technology of vacuum gas dosing. Handling,
More informationConstant and Particle Free Point-of-Use Water Pressure
Constant and Particle Free Point-of-Use Water Pressure for High Quality UPW and DI-Water Always the right pressure. Higher Cost Pressure and More Rigid Specifications In the Microelectronic world pressure
More informationDIAPHRAGM VACUUM PUMPS AND COMPRESSORS
DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 2400 N 2400.15 ST.9 E Concept The diaphragm pumps from KNF arebased on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its
More informationMICRO DIAPHRAGM GAS PUMPS
MICRO DIAPHRAGM GAS PUMPS DATA SHEET E 5 NMP83KNE NMP85KPDC NMP85.1.2KPDC-B Concept The micro diaphragm gas pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge, moves
More informationIntroduction to Pumps
Introduction to Pumps 1 Introduction to Pumps 1.0 INTRODUCTION There are many different types of pump now available for use in pumped fluid systems. A knowledge of these pump types and their performance
More information3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX
/-way valve, Series CD07 Version Spool valve, zero overlap Sealing principle soft sealing Working pressure min./max. -0.95 bar / 0 bar Ambient temperature min./max. -5 C / +80 C Medium temperature min./max.
More informationTECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1
Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a
More informationSKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function
SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function Technical Instructions Document No. 155-752 SKP25 U.. Description Only when assembled to Series VG Gas valves SKP25
More informationCopyright, 2005 GPM Hydraulic Consulting, Inc.
Troubleshooting and Preventive Maintenance of Hydraulic Systems Learning to Read the Signs of Future System Failures Instructed by: Al Smiley & Alan Dellinger Copyright, 2005 GPM Hydraulic Consulting,
More informationEXH. Specifications. Descriptions. Min. working pressure MPa
Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,
More informationThe HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.
The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is
More informationTECHNICAL DATA. Page 1 of 12
Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control
More informationExplanations hydraulic valves TECHNICAL EXPLANATIONS HYDRAULIC VALVES. Contents. 1. Foreword. 2. Characteristic Values
TECHNICAL EXPLANATIONS HYDRAULIC VALVES Contents 1. Foreword 2. Characteristic Values 2.1. Characteristic Values for Directional Control Valves 2.1.1. Standard Values 2.1.2. General Characteristic Values
More informationair driven Standard air gas liquid for high pressure: contents Chatsworth, California, USA
air driven Standard sp-100b system packages for high pressure: air gas liquid contents Standard Liquid Pump Packages 2, 3 Standard Gas Booster Packages 4, 5 Standard Air Pressure Amplifier Packages 6 Custom
More informationAuto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance
More informationPLD 03 T A CASAPPA S.p.A.
GEAR FLOW DIVIDERS INDEX Section Page GENERAL FEATURES... 3 GENERAL DATA... 5 FLOW EQUALIZER... 6 FLOW DIVIDERS... 8 TYPICAL CIRCUITS... 10 NOTES ABOUT COMPOSITION... 12 PORTS DIMENSIONS.... 14 GROUP DIMENSIONS...
More informationfor Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity)
for Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity This is a Pilot operated pressure reducing valve. It is suitable to install in the steam lines with the
More informationSuperFinish 27. Available versions. Accessories. SuperFinish 27 Spraypack. Basic unit. Tip extensions / pole guns. Suction systems.
Available versions Spraypack Basic unit 0341 051 basic unit on trolley including pressure gauge system + QuickClean suction + 15 m high pressure hose + Airless gun G 12 + Wagner Tip holder with Airless
More informationBooster Regulator/Air Tank
Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed
More informationHydraulic hand spindle pump Models CPP1000-M, CPP1000-L
Calibration Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L WIKA data sheet CT 91.05 for further approvals see page 2 Applications Calibration service companies and service industry Calibrations
More informationHANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:
HANDBOOK Squeeze Off Unit SOU 250 Please refer any queries to: Hy Ram Engineering Co Ltd Pelham Street Mansfield Nottinghamshire NG18 2EY Telephone No: (01623) 422982 Please note all queries should state
More informationHow to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size
Booster Regulator Series VBA How to Order VBA 0 series VBA 0 0 Body size /4 Pressure: MPa Pressure increase ratio 0 Twice Thread type Symbol F Thread type G Port size Symbol Port size 0 /4 Symbol VBA0-0
More informationDevelopments on Flow Rate And High Pressure Stability of Peroxide Dosing Pumps For The Chemical Industry
Developments on Flow Rate And High Pressure Stability of Peroxide Dosing Pumps For The Chemical Industry Franz Trieb, Reinhard Karl, Rene Moderer Bohler Hochdrucktechnik GmbH Kapfenberg, Austria www.bhdt.at
More informationHand lever valves VHER
Hand lever valves VHER Hand lever valves VHER Key features Powerful Flexible Practical -M- Flow 170 3800 l/min 4/3-way valve mid-position closed mid-position exhausted mid-position pressurised Connections:
More informationGENO -Flushing Compressor Product Data Sheet F 02
GENO -flushing compressor 1988 K Fig. 1: GENO -flushing compressor 1988 K Designated application is suitable for the following fields of application: Flushing of pipes with water/air mix prior to the start-up
More informationFull-Vacuum Chlorinator C 2212 MB / 1
MB 2 04 12 / 1 Purpose of full-vacuum chlorinators Chlorine gas is important for the disinfection of potable and swimming pool water but also represents a source of danger as far as handling, transportation
More informationCoriolis Mass Flow Meter
Coriolis Mass Flow Meter TMFW Series Mini Type Coriolis Mass Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com;
More informationBeamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL
Beamex PG PRESSURE GENERATORS 97 Beamex PGM PGV PGC PGHH PGPH PGL Beamex PG pressure generators are portable hand-operated pressure generators and ultimate field calibration pumps 98 Calibration pumps
More informationerc-o 2 -tech Ò innovative gas systems Markwerbener Str Weißenfels Germany
Compart Umwelttechnik GmbH erc-o 2 -tech Ò innovative gas systems Markwerbener Str. 24 06667 Weißenfels Germany Phone: 0049 (0) 3443/2901-0 Fax: 0049 (0) 3443/2901-12 Mail: compart-weissenfels@t-online.de
More informationOperation Manual Air Saver Unit ASV5000 Series
9IM-V066-b Operation Manual Air Saver Unit ASV5000 Series Thank you for your choice of Kuroda Pneumatics LTDs product on this time. Please read this operation manual carefully and use the product correctly.
More informationTECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY
Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry
More informationOxygen Usage Best Practice Guide
Oxygen Usage Best Practice Guide 1. Introduction Oxygen enriched systems possess a risk of fire and explosion since ignition and combustion hazards are present in all oxygen systems, and oxygen related
More informationWORKHOLDING APPLICATION BOOKLET
WORKHOLDING APPLICATION BOOKLET Applications and advantages of using minibooster hydraulic pressure intensifiers MINIMUM SIZE MAXIMUM POWER B-GB Workholding 2018.04 1 of 20 2 of 20 B-GB Workholding 2018.04
More information