OCTO SRB9150 SRB9350 BRUT MAGNUM SECOND STAGES SERVICE GUIDE
|
|
- Cecil Bryan
- 5 years ago
- Views:
Transcription
1 SR9952 OCTO SRB9150 SRB9350 BRUT MAGNUM SECOND STAGES SERVICE GUIDE 1
2 INTRODUCTION The instructions set forth in this document are intended to guide the experienced scuba equipment repair technician through the standard service procedure for this Sherwood regulator. It is assumed that the technician possesses basic scuba equipment repair training, proper tools and the skill necessary to perform the service. If you have not received regulator service training provided by Sherwood Scuba specifically for this equipment, do not attempt to perform the service described in this document. Service parts for Sherwood equipment are sold only to Authorized Sherwood Dealers. Before attempting to perform service read this manual in its entirety. There are warnings and cautions contained in the manual that may affect your safety or the safety of the regulator user. If you are uncertain as to whether you are qualified to perform this service contact your regional Sherwood Scuba Distributor for technical assistance. USE OF WARNINGS, CAUTIONS AND NOTES WARNING: CAUTION: Indicates a potentially hazardous condition or situation which, if not avoided, may result in serious injury or death. Indicates a potentially hazardous condition or situation which, if not avoided, may result in minor injury. It may also be used to alert against unsafe practices. NOTE: Indicates an important point or reminder. REGISTRATION, INSPECTIONS AND SERVICES ON-LINE REGISTRY. All Sherwood regulators have to be registered right after purchase, either by the end consumer or the dive center where the item was acquired. If the dive center is not able to register the product for the end-consumer at the time of purchase, the sales associate form the dive center has to strongly encourage the end-consumer to register his/her product within 30 days after purchase. Effective immediately: recording inspections and services is required to ensure the proper continuity of the warranty process. Regardless of location, proper record keeping by the authorized dealer is required right after each inspection or service is performed. When the regulator is going to be used for recreational purposes a year or 150 dives after purchase an inspection is required; a year after such inspection or when the regulator has completed 300 dives a full service is required. Time frames may be different when the regulators are going to be used for public service, rental or instructional use. Please contact your local Sherwood Sales representative for additional information to discuss particular cases and usage. Recording information at our website: Go to & using your dealer credentials click on the Product Warranty tab and follow the instructions to record Inspection or Service. It is imperative that the Authorized Dealer record these events. 2
3 WHEN TO SERVICE Sherwood regulators are designed and tested to perform acceptably under typical recreational diving conditions up to 300 hours of use. This Sherwood regulator should be inspected at least annually to evaluate it s performance. In most cases a simple inspection, and if needed, minimal adjustment not requiring the replacement of parts will be sufficient for continued use If the regulator has been subjected to more than 300 hours of use or it has not received the benefit of careful post-dive cleaning and storage in a clean environment, a standard service overhaul is required. In any case the Sherwood regulator described in this manual should receive a standard service overhaul at least every two years to maintain optimal performance. The standard service overhaul includes disassembly, cleaning, inspection, replacement of seals, lubrication, reassembly and adjustments. Regulators that are used in extreme conditions, such as commercial, public service use or rentals require more frequent service overhauls of at least every 3 to 6 months. A qualified technician should be able to determine service frequency. Sherwood Scuba offers a standard service kit that contains the parts recommended to be replaced in connection with the standard service overhaul. PN# 9350PK covers 1st and primary 2nd stage Brut PRO SRB9150 and Magnum PRO SRB9350 & PN# 9952PK contains the parts to service Sherwood Octo SR9952 ANNUAL INSPECTION GUIDELINES 1. Visually inspect the first and second stage for signs of damage or deterioration. Mouthpieces with tears or other damage should be replaced. 2. Retract hose protectors and inspect the hose over its entire length for signs of damage including blisters, deep cuts or separation at the crimped fittings. If these signs are present the hose must be replaced and standard service overhaul is recommended. 3. Insert a soft probe through the exit port of the exhaust cover and lift the Exhaust Valve to inspect it for cuts, tears or contaminated surfaces. Perform this examination from both sides of the Exhaust Cover to observe the entire perimeter of the Exhaust Valve. If damage to the Exhaust Valve is found a complete overhaul is recommended. If the Exhaust Valve or the sealing surfaces on the Housing are contaminated with debris, the Exhaust Cover must be removed and the surfaces must be cleaned. Instructions for removing and replacing the Exhaust Cover appear in the Second Stage Service Guide. As a final check of the Exhaust Valve apply a moderate suction (approximately minus 5 inches of water, moderate inhalation effort) to the second stage mouthpiece with the air supply closed and the second stage purged. If leakage is detected a complete overhaul is recommended. 4. Inspect the first stage filter for evidence of contamination. Discolored filters indicate previous contact with contaminated air. If evidence of contamination is present it is recommended that a standard service overhaul be performed. In addition you should advise the customer that the regulator has been exposed to contamination and that previously used air cylinders used should be inspected. 5. Install an intermediate pressure gauge into one of the available LP ports. 6. Pressurize the regulator to approximately 500 psi and inspect for leakage. Note intermediate pressure. It should not be greater than 155 psi. If no leakage is detected increase inlet pressure to 3000 psi. Again check intermediate pressure. It should not exceed 155 psi. If intermediate pressure is out of range 145 +/- 10 psi or leakage is present a standard service overhaul is recommended. 7. Test the purge function. If there is not a strong surge of air, a standard overhaul is recommended. 8. Gently submerge the entire regulator and look for bubbles that indicate leakage. If leakage is present a standard service overhaul is recommended. 9. If a test bench is available perform an inhalation test. Inhalation effort should not be greater than 2.0 inches of water at opening and less than 5.0 inches of water at 15 SCFM. If a test bench is not available perform a subjective breathing test. When properly adjusted the regulator should provide smooth and easy inhalation. If difficulty with inhalation is suspected a standard overhaul is recommended. 3
4 GENERAL COMMENTS NOTE Read this section before attempting to perform service. 1. Read the entire set of procedures that follows before starting to service. Steps taken out of sequence or without the knowledge of the proper procedure could damage the regulator or otherwise complicate the service process. 2. Refer to the Illustrated Parts List while performing service. Each part is identified with an item number the first time it appears in the text. Parts that are to be replaced with new parts in conjunction with an overhaul have encircled reference numbers. 3. Do not attempt to reuse parts that are designated for replacement. Retain discarded parts to show to the customer to illustrate that a full overhaul service has been completed. 4. Work in a clean properly equipped area. Cleanliness is essential for all regulator servicing and is critical for regulators that will be exposed to enriched air mixtures (Nitrox). Do not attempt to service if all required tools and a clean work area are not available. 5. Work on one regulator at a time taking care not to mix parts from other regulators. Use only genuine Sherwood parts. Parts that appear similar may have different features that are not easy to detect and may cause poor performance. 6. Be careful to protect the finish on all surfaces of the regulator during the service procedure. When holding parts in a vise use soft or padded jaws to prevent defacing surfaces. 7. O-rings are classified by the service they perform and are identified as either static or dynamic. Dynamic O-rings are those that are subjected to movement and the effects of friction which tend to shorten the useful life of the O-ring. Static O-rings are used to create a seal between non-moving parts and are not subject to the same wearing effects. Static O-rings have a longer useful life and are not replaced unless they show signs of deterioration or brittleness. Careful inspection of these O-rings is required before they are returned to service. Lubrication of O-rings: a. All lubrication must be done with Tribolube 71 or Christolube MCG-111. b. General O-rings in most instances should receive only enough lubricant to ensure they are supple. A light coating of lubricant should present a surface that glistens but without a defined layer of lubricant visible. c. Ample When an ample application of lubricant is specified it generally applies to a dynamic O-ring subject to considerable motion or environmental conditions where a more generous application of lubricant might be beneficial. In this situation there should be a light film or layer of lubricant visible. General Ample 8. When removing O-rings use a plastic or a soft brass tool to lift the O-ring out of its groove. Do not use steel or other hard tools that might scratch sealing surfaces. 9. When instructed to use tools such as a hex key or a wrench, follow the standard convention to rotate clockwise to tighten and counterclockwise to loosen unless otherwise directed. 10. When instructed to tighten a part until snug, it means to apply torque just until the part stops moving freely and the torque requirement to advance it further rises markedly. When specific torque specifications are given there is a necessity to ensure that the part is tightened enough to retain position or to create a seal. Unless you are skilled at accurately estimating torque, a torque wrench should be used. Excessive torque may damage parts and require replacement. 4
5 ENRICHED AIR NITROX SERVICE The Sherwood regulator presented in this manual has been designed and manufactured to allow the use of Enriched Air Nitrox (EAN) gas with an oxygen component not to exceed 40%. In order to maintain this option the user must ensure that the regulator is protected from the introduction of hydrocarbons. The introduction of hydrocarbons into the regulator may increase the risk of fire when used with EAN. When servicing the regulator, the technician must be aware of this requirement and exercise caution not to contaminate the regulator with hydrocarbons. This requires a clean workplace, free of oil, grease, debris and other contaminants. Additionally in order to return the regulator to EAN service, the overhaul procedure must have a cleaning provision to remove all hydrocarbons before the regulator is reassembled. Do not substitute parts or use lubricants other than Tribolube 71 or Christo-Lube MCG 111. Silicone lubricants are not acceptable and increase the risk of a fire hazard. WARNING The introduction of hydrocarbons, lint, dirt and other contaminants into the areas of the regulator subjected to high pressures (greater than 500 psi) and EAN mixtures containing more than 40% oxygen may constitute a fire hazard and may subject the user to serious injury. FACILITY REQUIREMENTS The service facility is perhaps the most important asset of any professional dive store. It should be clean, well lighted, and stocked with a complete inventory of parts and manufacturer s specialty tools for the products your store sells. As a minimum requirement, your service facility should be equipped with the following items: Ultrasonic Cleaner - Select the right size model that can keep up with the volume of regulators that your store services. A built-in timer and heater will help control the cleaning time and temperature of the solution, since most solutions work best when heated. Bench Mounted Padded Vise - A vise is sometimes needed to hold the regulator secure especially when removing the first stage yoke retainer. Special care must be taken, however, to avoid damage that can result from improper use of this tool. Vise must be lined with soft material like rubber or wood. Be sure to follow the instructions provided in this manual. Magnification Lamp - Strong lighting and magnification are essential requirements for performing a thorough parts inspection - especially when locating the cause of a small leak. Quality Wrenches & Sockets - When working with chrome plated brass parts, it is especially critical to use the correct size wrench and to ensure that it fits properly over the part. The use of an adjustable wrench is very likely to cause damage to your customer s regulator, and should be strictly avoided at all times. Calibrated Inch-Pound Torque Wrench - it is important to follow the manufacturer s torque values whenever they are specified, in order to avoid over-tightening or under tightening a part. This is especially important for smaller parts and fittings, when over-tightening can easily damage the part. Calibrated Foot-Pound Torque Wrench - Torque wrenches that can be set for both inch-pound and foot-pound measurements generally tend to be less accurate than wrenches that are designed to measure torque within a specific range. Manufacturer s Specialty Tools - Specialty Tools are critically important to perform many of the steps during disassembly and reassembly according to each manufacturer s procedures. During the mentioned steps where the procedure clearly indicates the use of a specialty tool, Sherwood Scuba strongly discourages technicians the use of substitute or make-shift tools to perform such steps. Sherwood specialty tools required to perform service are listed on page 7. 5
6 SECTION SECOND STAGES RECOMMENDED TOOLS AND SUPPLIERS The specialty tools identified below may be purchased from your Sherwood Scuba Distributor. Common tools are available from several sources. Common Tools Open End Wrenches - 9/16, 5/8, 1/2 Hex Tool 5/32 Small Flat Blade Screw Driver - Wiha 260/3.5x60 Diagonal Pliers (wire cutters) Torque Wrenches 25 ft-lb and 60 in-lb (25 N-m and 10 N-m) Flashlight Compressed Air Gun O-ring picks, plastic or soft brass Magnifier or Stereoscopic microscope Specialty Tools Orifice Driver O-ring pick set, soft brass In-Line Adjustment Tool piece set Picks/ Flat Screw Drivers Balanced Poppet Insertion Tool
7 SECTION SECOND STAGES - DISASSEMBLY PROCEDURES 1. Retract hose protector (6) to expose the hose s swivel nut. 2. Use a 5/8" open end wrench to rotate the hose swivel fitting nut counterclockwise to separate the hose from the 2nd stage assembly. 3. Remove tie wrap (3) and mouthpiece (17, 17a or 17b). CAUTION When performing the next steps to remove the Purge Cover be careful to avoid placement of the probe or screwdriver between the Housing and the Diaphragm Retainer or prying up the tool rapidly. Incorrect tool placement or procedure increases the risk of damage to the Diaphragm and/or Diaphragm Retainer requiring replacement of the parts. 7
8 4. Locate notch at the bottom of the housing (9 or 9a) and start inserting the flat screwdriver Wiha 260/3.5 x 60 (contained in kit ) in between the lip of the purge cover and the housing 5. Carefully continue inserting the screw driver until it passes through one of the orifices at the top of the purge cover. Use that orifice area as a pivoting point for the next step. 6. While holding the cover with one or more fingers use the tool on a circular motion to facilitate the separation of the purge cover s lip from the regulator s housing. Holding the cover while separating it, prevents the cover from flying off the 2nd stage s housing. 8
9 7. After separating the purge cover we will have access to the diaphragm retainer (18 or 18a) and diaphragm (29 or 29a). Remove all those components and place them on a safe place for inspection & re-use. 8. Align the c-clip (4) with the housing molding mark shown to facilitate extraction. Use the same screw driver form step 4; and place its tip at the clip s notch. CAUTION Failure to extract the clip in an angle as indicated will increase the risk of breaking it. 9. Extract C-clip with an upwards and at-an-angle motion until it gets completely off the Venturi switch (10) or Access Plug (10a). 9
10 10. Extract Venturi Switch or Access Plug. 11. Remove the o-ring (16) from the Venturi Switch s or Access Plug s channel with a soft material pick. 12. Using a 11/16 wrench or a Crescent Wrench remove the retaining nut (23) by unthreading it counterclockwise and pull out the washer (22). It is likely that the nut will already be un-torque and lose after having removed the hose s swivel nut on a previous step. 13. Depress the demand lever (21) and carefully push the valve body assembly inwards. Make sure you collect the o-ring (16) that will likely fall off after it loses contact with the valve body assembly. 10
11 14. With the demand lever depressed continue removing the valve body assembly and valve flange (19). Be cautious not to press too hard to prevent deforming the demand lever. Place all the components on a safe place. 15. Rotate the Adjustable Balancing Chamber (27) counterclockwise to remove it. It is likely that the spring (26), Thrust Washer (14) and Poppet (25) washer will come out at the same time. Place those components aside. 16. Insert the driver side of a Poppet/Orifice Installation Tool ( ) through the threaded end of the valve body (20) and rotate orifice (11) counterclockwise until it has reached its last thread. 11
12 17. The o-ring (15) at the orifice will prevent the orifice assembly from been extracted completely even though the threads are not engaged; use the soft end of a Blunt Probe Pick ( Contained in kit) and push from the other end to carefully guide the orifice out of the valve body. 18. Using a soft material probe (brass or plastic) remove the o-ring from the orifice. 19. Go back to the components in step #14 & separate the Poppet (25), Thrust Washer (14), Spring (26) and Adjustable Balancing Chamber (27) and set them aside on a safe place for inspection and re-assembly. 12
13 20. Using a soft probe (brass or plastic) remove the o-ring (28) off the poppet (25) and discard it. 21. Remove and discard the LP seat (24) from the poppet and discard it. NOTE The following steps (22 24), to remove the Exhaust Tee and Exhaust Valve are only required when replacing the exhaust valve. These steps are not necessarily required on every single overhaul, only when regulator is excessively dirty or the exhaust valve is suspected to be damaged and needs to be replaced. Test Exhaust Valve consistency by pushing it against the housing. Only if it is losing resiliency it will fail to return to its original shape & will require to be replaced. 13
14 22. Locate Exhaust Tee Retaining Screws (2) inside the housing and with a Phillips screwdriver remove them by unthreading counterclockwise. Place screws on a safe place for inspection and reassemble. 23. Go to the opposite side & remove Exhaust Tee (13) by pulling it outwards. Put it in a safe place for inspection and re-assembly. 24. To remove the Exhaust Valve (1) pull evenly from both ends first; the insertion tip needs to be pulled slightly to facilitate its removal through the orifice, once this end has changed its shape slightly now pull the round valve end outwards. Once removed put Exhaust Valve on a safe place for inspection and re-assemble. 14
15 SECTION 2nd STAGES - GENERAL CLEANING AND INSPECTION PROCEDURES CLEANING: 25. Thermoplastic, silicone rubber and anodized aluminum parts, such as diaphragms, accent trim, adjustment knobs, static/ replaceable O-rings, and thermoplastic housings. a. Soak in a solution of warm water and ordinary liquid dish detergent. Scrub with a soft nylon bristle brush to remove deposits. b. Do not subject thermoplastic or rubber parts to ultrasonic cleaning or vinegar solutions. c. Rinse with fresh water and blow dry with clean low pressure compressed air. WARNING When heavy corrosion has developed, metallic parts will lose their chrome plating after time. The use of an ultrasonic cleaner may accelerate such loss and chrome peeling will develop. If the parts you are intending to clean present heavy mineral build up be cautious, and continue monitoring the parts immersed in the ultrasonic cleaner periodically. Start the process by using the ultrasonic cleaner for only 1-2 minutes, extract the part (s) and evaluate the chrome finish for peeling. 26. Chrome-plated Brass and Stainless Steel parts only Use a commercial grade Ultrasonic Cleaner with LFW (Lawrence Factor Wash). LFW should be used diluted at a concentration no higher than 1:4 LFW/Water ratio to ensure good penetration, mineral build up removal but also ensuring chrome plating protection. (Follow manufacturer s recommendations for your particular ultrasonic cleaner brand). The use of a heated ultrasonic cleaner will accelerate the cleaning process; most mineral buildup on heavily soiled metallic parts can be cleaned with a minute treatment with LFW diluted to 25% on a heated ultrasonic cleaner. WARNING If after a preliminary cleaning (1-2 min) metallic parts present heavy pitting and substantial damage particularly to sealing surfaces it is advisable to replace the whole part after the evaluation. Alternatively the use of household vinegar or warm water and a brush could be considered as a method to clean metallic parts but be mindful that such processes may not go to deeper ends of some metallic parts such as small inner threads, channels, sealing surfaces, etc, and corrosion build up may remain. The use of an ultrasonic cleaner proves valuable when sealing or friction surfaces can t be reached easily. Regardless of the method used, rinse all metallic parts right after the cleaning process thoroughly with fresh water and blow them dry with compressed air. 27. Hoses - a. Corrosion or mineral deposits on the metallic fittings on hoses may be cleaned using the procedure presented above provided that care is taken to dip only the metal fittings at each the end of the hose into the cleaning solution. Take care to prevent access of the solution into the hose inner conduit. b. Rinsing should include flushing the interior of the hose with fresh water followed by drying with compressed air. 15
16 INSPECTION: 28. Use a powerful magnifying glass or stereoscopic microscope if available to evaluate chrome plating at sealing surfaces. These surfaces must be free of scratches, blemishes or peeling to effectively seal against o-rings. Replacement of the whole part may be necessary if the mentioned imperfections are pronounced. 29. With magnifying glass or stereoscopic microscope if available, inspect orifice s sharp edge seating surface; this must be free of nicks, deep scratches and blemishes in order to seal properly. Replace if needed. 30. Inspect the integrity & flexibility of Diaphragm (29) and Exhaust Valve (1) by stretching them slightly, ensure they do not have cuts or deformities. Replace if needed. 31. Ensure you spend sufficient time during inspection and pay special attention to the physical integrity of all com ponents. Contact your regional distribution center s technical department if you have questions. SECTION 2nd STAGES - REASSEMBLY PROCEDURES NOTE If removal of Exhaust Tee and Exhaust valve was required follow steps 32 35; if not, skip to step Insert the tip of the Exhaust Valve (1) in the receiving orifice. 33. From the other end, pull the valve s insertion tip slowly until its tapered shape has come out all the way through the orifice. Light lubrication may help. 34. Ensure that the Exhaust Valve its placed correctly by slightly lifting it on various places, pushing down on it and by running a finger all around it. 16
17 WARNING Make sure not to apply too much torque when tightening the screws on the next step, otherwise the screw s threads will permanently deform the plastic from the housing. If that would to occur replacing the entire housing will be required. 35. Locate the Exhaust Tee (13) and the two Exhaust Tee Retaining Screws (2). Insert the Exhaust Tee applying low and even pressure by hand until it has reached its place; ensure its edges feel flush against the surface of the housing. Insert both screws and set them by hand first, then thread them in with a Phillips screw driver rotating clockwise until they bottom & feel secured; only low hand tight force is required. 17
18 36. Light lubrication to LP Seat s stem may be beneficial to facilitate insertion into poppet. 37. Insert the new LP seat (24) and ensure it sits flush against the poppet (25). 38. Amply lubricate a new o-ring (28) and install it at the outer channel on the poppet stem. 18
19 39. Using Poppet alignment tool insert poppet while demand lever (21) is lifted about 90 ; once pop pet is in, ensure that the poppet contact tabs have engaged with the Demand Lever cams properly by slightly and carefully rotating the tool and feeling where the poppet stops. If the poppet contact tabs have effectively engaged into the demand lever cams a slight resistance should be felt; if it rotates freely, it has not engaged correctly. Repeat step accordingly to ensure proper poppet placement in relationship with demand lever. 40. Carefully push the tool in and let it go to test transfer of movement; if the components have engaged correctly you d notice that by slightly pushing the tool inwards the demand lever will rise; letting the tool go, the demand lever will slowly fall. If transfer of movement is not effective do not move to the next step. NOTE If transfer of movement is not present or excessive resistance is felt, do not proceed to next steps. Correct as needed to ensure poppet is set correctly and transfer of movement is effective. 41. Extract tool. The Demand Lever should lay flat against the valve body at this point. 19
20 42. Locate Spring Bushing (14) and Spring (26). Before installing, ensure Spring Bushing s polished side is facing up to get in contact with spring s flat end coil. Insert Spring Bushing first and then Spring. 43. Lubricate the inside of the Adjustment Screw/ Balancing Chamber (27). 44. Start threading the Adjusting Screw (Balancing Chamber) clockwise. If previous steps were performed correctly, you d notice that while threading the demand lever will gradually rise and resistance to threading will increase; this will trans late in a gradual increased force applied to the spring that consequently will translate in higher breathing effort. Pre-set of the Adjusting Screw will be described on the following steps. 20
21 45. Test that the internal components of the Valve Body Assembly are operating properly by depressing the demand lever and letting it go repeatedly. A consistent and even resistance should be noticed throughout the demand lever s complete range of motion. 46. Once the Adjusting Screw/ Balancing Chamber (27) is flush against the edge of the valve body, thread one more turn inwards. That will be a good starting point to pre-set the spring force and Opening Effort. Calibration of the final O.E. using the Adjusting Screw will be described in Section Locate Valve Flange (19) and insert it in the right hand side of the 2nd stage s Housing (9 or 9a). 21
22 48. Ensure the Valve Flange square shape sits flush against the housing s square index feature. 49. Insert the Valve Body Assembly into the housing. Depress the demand lever carefully while the valve body gets inserted. 50. Continue guiding the Valve Body Assembly in slowly until it reaches the Valve Flange s end and both components square indexed features feel secured against the housing. All the threads of the Valve Body Assembly should be visible at the other end of the housing at this point. 22
23 51. Locate O-ring (16) and insert it over the Valve Body Assembly s threads all the way to the bottom. Proceed in the same fashion with the Washer (22). 52. Locate the nut (23) & by hand start rotating it clockwise over the Valve Body s threaded end until it bottoms against the washer. 53. Torque nut to 32 in lb. Apply torque rapidly to avoid thread deformation. 23
24 54. Locate Orifice (11) and install a new amply lubricated o-ring (15). 55. Insert the Orifice Assembly (sharp end first) through the threaded end of the Valve Body Assembly. 56. Using the driver end of a Poppet/Orifice Installation Tool ( ) thread the Orifice Assembly only 5 & 3/4 turns in. This pre-set will cause a free flow when the system gets pressurized. As a general precaution depress the demand lever to ensure the rotation of the orifice will never damage the surface of the seat in case more than 5 & 3/4 turns are applied. 24
25 57. Locate Ventury Switch (10) or Access Plug (10a) and install a generally lubricated o-ring (16), make sure it gets installed on the outer channel; (the inner channel is designated to receive the c-clip once the part is inserted into the housing). 58. Insert the Ventury Switch (10) on Magnum PRO or Access Plug (10a) on Octo or Brut PRO into the housing. 59. Locate the C-Clip (4) and install it securing the Venturi Switch or Access Plug (Octo & Brut PRO). When working on a Magnum PRO SRB9350, after installing C-Clip, test that the Venturi Switch (10) rotates freely within its range of motion. 25
26 60. Locate the Diaphragm (29 or 29a) and Diaphragm Retainer (18 or 18a). Before installing, locate the alignment marks on both and make sure they coincide before installing into the Housing (9). Assemble together. 61. Place Diaphragm w/ Diaphragm Retainer into the housing & aligning both their marks against one of the housing s molding marks. (The Housing s upper or lower molding marks will work just the same). 62. Locate Purge Cover (30, 30a or 30b) and ensure the Sherwood logo is aligned properly. 26
27 63. Start with one of the Purge Cover s ends engaged with the housing s plastic lip, (always start inserting purge cover at an angle with the housing). 64. Using both hands apply equal force sliding both thumbs over the Purge Cover at the same time until the bottom part of the cover s lip has met the Housing s channel completely. 65. Look all around the perimeter where the purge cover meets the housing and ensure it has engaged properly. Run your finger around the assembly to ensure an even fit. 27
28 SECTION 5 2nd STAGES - CALIBRATION PROCEDURES 66. Using an in-line adjuster and pressurized air supply proceed to test lever height and Opening Effort (O.E.). 67. Connect the 2nd stage to the in-line adjuster and the other end of the tool to a source of pressurized breathing air delivering 145 +/- 10 psi supply pressure; ensure the shaft of the tool has already engaged with the orifice s slot before starting the flow. WARNING If the orifice frictions against the LP seat this action will eventually cut the seat damaging it permanently requiring disassemble, replacement and re-calibration. Ensure the regulator purge is depressed every time the tool s adjustment wheel is rotated to prevent damaging the seat with the orifice s sharp edge. Purge 2nd stage prior & during each rotation. 68. Start the air flow. The original orifice s pre-set (Step #56) will produce a free flow. Use tool to adjust orifice (depressing purge every time tool s wheel is rotated) until leak stops but regulator is easy to purge. Cycle purge 20 to 30 times. Test lever height by purging the regulator one more time. If the purge is too sensitive (air flows immediately after barely touching the purge),re-calibrate orifice one more time as needed. NOTE There should be a reasonable gap in between the diaphragm s contact plate and the curved end of the demand lever; often this mentioned gap is noticeable (audible) by shaking the 2nd stage repetitively while pressurized, a very subtle rattle should be perceived indicating the presence of a small gap. If this gap is wider (louder rattle) the regulator will be difficult to purge. 69. Locate Mouthpiece (17, 17a or 17b) and install it evenly over the opening. 70. Secure the mouth piece with a Tie Wrap (3) and cut the excess. 28
29 71. De-pressurize the regulator assembly and remove the in-line Adjustment Tool from both the regulator and the hose. Install the hose assembly back to the 2nd stage and tighten the swivel nut to approximately 40 in lb. Push the hose protector (6) towards the housing to cover the hose fitting completely. 72. Cycle the regulator 30+ times by depressing and releasing the purge at regular intervals. 73. Using a Magnehelic gauge with a scale 0 3 inches of water measure initial opening effort. It should be between: OCTO PRO BRUT PRO MAGNUM PRO If the Opening Effort needs to be modified, remove the Port Plug (5) with a 5/32 hex key at the Venturi switch (10) on Magnum or Access Plug (10a) on Brut & Octo. All Sherood Octo, Brut and Magnum PRO models now require the use of a 7/32 hex key to access the Adjustment Screw/Balancing Chamber in order to increase or decrease the spring load. Clockwise rotation will increase the spring force and therefore increasing the Opening Effort (harder to breath from); counterclockwise rotation will decrease spring force, decreasing O.E at the same time (easier to breath from). WARNING Adjusting the opening effort lower than the recommended values will increase the risk of free flow; the 2nd stage could become too sensitive, unstable and prone to leak under real diving conditions. It is very important not to set O.E. lower than recommended. 75. If adjusting the initial Opening Effort was required, replace the Port Plug (5) at the Venturi Switch (Magnum PRO) or Access Plug; (Octo & Brut PRO) secure it hand tight only. Avoid over-torque & deforming threads. 76. Cycle the regulator again 30+ times as described in step # 68. Submerge the 2nd stage in water while pressur ized & inspect for air leaks or any other abnormalities, check O.E. again and troubleshoot if required. 77. Contact your local Sherwood distributor if additional technical assistance is required. THIS CONCLUDES THE SERVICE PROCEDURES FOR OCTO, BRUT AND MAGNUM PRO 2ND STAGES. 29
30 Magnum PRO, Brut PRO & Octo PRO SECOND STAGES a 30a ITEM PART # DESCRIPTION 1 SHV7006 EXHAUST VALVE 2 SHV7027 EXHAUST TEE RETAINING SCREWS 3 SHV7026 TIE WRAP 4 SHV7025 C CLIP 5 SHV7023 LP PORT PLUG 6 SHV7032 HOSE PROTECTOR, SHORT 7 SHV7031 HOSE PROTECTOR, LONG 8 SHV7530 HOSE ASSEMBLY 9 SHV6003 HOUSING WITH VANE 9a SHV7021 HOUSING (Brut/Octo) 10 SHV6002 VENTURI SWITCH, MAGNUM 10a SHV7022 ACCESS PLUG, BRUT/OCTO 11 SHV7016 ORIFICE O-RING 13 SHV7024 EXHAUST TEE 14 SHV7751 SPRING BUSHING O-RING O-RING 17 SHV5030 MAGNUM MOUTH PIECE (GREY) 17a SHV5035 BRUT MOUTH PIECE (BLACK) ITEM PART # DESCRIPTION 17b SHV5034 OCTO MOUTHPIECE (Yellow) 18 SHV6001 CHROME DIAPHRAGM RETAINER 18a SHV7012 BRUT/OCTO DIAPHRAGM RETAINER 19 SHV8350 VALVE FLANGE 20 SHV5062 VALVE TUBE 21 SHV5060 DEMAND LEVER 22 SHV8352 RETAINING WASHER 23 SHV8353 RETAINING NUT 24 SHV5065 LP SEAT POPPET SPRING 27 SHV5061 ADJUSTMENT SCREW (Balancing Chamber) O-RING 29 SHV7008 BLACK DIAPHRAGM (Magnum/Octo) 29a SHV7090 WHITE DIAPHRAGM (Brut) 30 SHV4475 MAGNUM PURGE COVER 30a SHV7009 BRUT PURGE COVER 30b SHV7009Y OCTO PURGE COVER *Circled parts included in service kit. 30
INTRODUCTION The instructions set forth in this document are intended to guide the experienced scuba equipment repair technician through the standard service procedure for this Sherwood regulator. It is
More informationSECOND STAGE SERVICE GUIDE
SECOND STAGE SERVICE GUIDE 200_08 SRB1000 INTRODUCTION The instructions set forth in this document are intended to guide the experienced scuba equipment repair technician through the standard service procedure
More informationSR2 Service Manual - Second Stage -
SR2 Service Manual - Second Stage - 1 INTRODUCTION The instructions set forth in this document are intended to guide the experienced scuba equipment repair technician through the standard service procedure
More informationMAINTENANCE PROCEDURE FOR X 650
MAINTENANCE PROCEDURE FOR X 650 X 650 25. juli 2005-1/6 MAINTENANCE PROCEDURE FOR X 650 2 ND STAGE WARNING: This maintenance procedure is only for appointed Scubapro technicians that completed a course
More informationSERVICE INSTRUCTIONS
SERVICE INSTRUCTIONS GEMINI BREATHABLE INFLATOR SR9000 INTRODUCTION The instructions set forth in this document are intended to guide the experienced scuba equipment repair technician through the standard
More informationService and Repair Manual
II stage R2 Ice/ Special, II stage R 1 Pro DOWNSTREAM 2 nd STAGE REGULATOR Service and Repair Manual Introduction Safety Precautions...4 General Procedures, Maintenance Schedules...5 Initial Inspection
More informationRG1200 Service and Repair Manual
Dive Rite RG 1200 Regulator Service and Repair Manual Page 1 Text and Photography by Pete Nawrocky Copyright ( ) 1999-2000, Lamartek, Inc., dba Dive Rite RG1200 Service and Repair Manual First Stage.........................................
More information12S 1st Stage. -Maintenance Procedure-
12S 1st Stage -Maintenance Procedure- 1 Warning! All maintenance and repair procedures MUST be performed by a Mares authorized Service Center and/or Distributor. Therefore, the information provided below
More informationSCUBAPRO Repair Guide. S600-S550 Second Stages
SCUBAPRO Repair Guide S600-S550 Second Stages S600 Configuration A S600 Configuration B USE THIS GUIDE AS A REFERENCE WHEN SERVICING THE S600 AND S550 SECOND STAGES S550 P/N 41-047-000 FOR REPAIR OF S600-S550
More information500SE SECOND STAGE SERVICE PROCEDURE
500SE SECOND STAGE SERVICE PROCEDURE This 500SE Service Procedure conveys a list of components and service procedures that reflect the 500SE as it was configured at the time of this writing. CONTENTS TROUBLESHOOTING...
More informationSERVICE AND REPAIR MANUAL SEAAIR REGULATOR PN RG200. Service & Repair Manual. Revised - 02/11
SERVICE AND REPAIR MANUAL SEAAIR REGULATOR PN RG200 Service & Repair Manual Revised - 02/11 SeaAir Regulator Contents Section 1 - Introduction Warnings, Cautions, & Notes...3 Scheduled Service...3 EAN/
More informationContents. Stainless Steel Side Block. 1.1 Separating the Side Block. Stainless Steel Side Block Reassembly of. Assembly from the Helmet Shell
Separating the Side Block Assembly from the Helmet Shell Contents SSB-1 SSB-3 SSB-5 SSB-5 SSB-7 1.1 Separating the Side Block Assembly from the Helmet Shell 1.2 Side Block Assembly Replacement 1.3 Defogger
More informationBalanced SCUBA Second Stage Regulator (P/N ) Maintenance Manual Contents
Before Going Further Introduction Balanced SCUBA Second Stage Regulator (P/N 200-120) Maintenance Manual Contents SCBAL-1 SCBAL-1 SCBAL-1 SCBAL-2 SCBAL-2 SCBAL-2 SCBAL-2 SCBAL-2 SCBAL-3 SCBAL-3 SCBAL-3
More informationRegulators repair and maintenance. XS Compact 2nd stage. January 2014 Rev XSC /3 Ed. C /14 1
XS Compact 2nd stage January 2014 Rev XSC /3 Ed. C /14 1 XS Compact 2nd stage WARNING! This manual is intended for use by expert technicians who have already received training in equipment repairs and
More informationSERVICE AND REPAIR MANUAL ALTAIR OCTO PN RG300. Service & Repair Manual. Revised - 02/11
SERVICE AND REPAIR MANUAL ALTAIR OCTO PN RG300 Service & Repair Manual Revised - 02/11 AltAir Octo Contents Section 1 - Introduction Scheduled Service... 3 EAN/ Nitrox Service... 3 Facility Requirements...
More informationMaintenance and Repair. AirHawk II Air Mask. Second Stage Regulator. Order No.: /02 Prnt. Spec (I) MSAsafety.
Maintenance and Repair Second Stage Regulator Order No.: 10104241/02 Prnt. Spec. 10000005389(I) MSAsafety.com WARNING! Read this manual carefully before servicing the device. The device will perform as
More informationTHERE WHEN YOU NEED IT
SPARE AIR SERVICE MANUAL FOR ALL MODELS 18072 Gothard Street, Huntington Beach, CA 92648 USA 800-648-DIVE P: 714-842-6566 F: 714-842-4626 www.spareair.com e-mail: info@submersiblesystems.com THERE WHEN
More informationSERVICE AND REPAIR MANUAL SPIRIT REGULATOR PN RG100. Service & Repair Manual. Revised - 02/11
SERVICE AND REPAIR MANUAL SPIRIT REGULATOR PN RG100 Service & Repair Manual Revised - 02/11 Spirit Regulator Contents Section 1 - Introduction Warnings, Cautions, & Notes... 3 Scheduled Service... 3 EAN/
More informationTECHNICAL TRAINING SS1
TECHNICAL TRAINING SS1 2003 1 Limited Lifetime Warranty Atomic Aquatics warrants the SS1 safe second/inflator against defects in materials and workmanship for the lifetime of the original owner with the
More informationBalanced SCUBA Second Stage Regulator (P/N ) Contents
Introduction (P/N 200-120) Contents SCBAL-1 SCBAL-1 SCBAL-1 SCBAL-2 SCBAL-2 SCBAL-2 SCBAL-2 SCBAL-2 SCBAL-3 SCBAL-3 SCBAL-3 SCBAL-3 SCBAL-4 1.1 Before Going Further 1.2 General Information 1.2.1 Introduction
More informationSERVICE & REPAIR MANUAL H.A.B.D.
Authorized Technician SERVICE & REPAIR MANUAL H.A.B.D. (Helicopter Aircrew Breathing Device) Rev. 02/16 2 H.A.B.D. Service & Repair Manual COPYRIGHT NOTICE This owner s manual is copyrighted, all rights
More informationContents. REX Regulator and Oral Nasal. 1.1 Regulator Performance Kirby Morgan Tools for the REX REX Regulator
Regulator Performance Contents REX-1 REX-1 REX-1 REX-2 REX-2 REX-3 REX-3 REX-4 REX-5 REX-6 REX-6 1.1 Regulator Performance 1.1.1 REX Regulator 1.1.2 Kirby Morgan Tools for the REX Regulator 1.2 REX Demand
More informationSERVICE & REPAIR MANUAL H.A.B.D.
Authorized Technician SERVICE & REPAIR MANUAL H.A.B.D. (Helicopter Aircrew Breathing Device) REVISED 12/07 H.A.B.D. Service & Repair Manual 2 Copyright Notice This owner s manual is copyrighted, all rights
More informationRB70 Automatic Diluent Valve Maintenance Manual. Version 1.1 November 2006 Written by Tino de Rijk. Page 1 of 23
RB70 Automatic Diluent Valve Maintenance Manual Version 1.1 November 2006 Written by Tino de Rijk Page 1 of 23 Table of Contents 1. Introduction... 3 2. ADV diagram and parts list (Pre June 2006)... 4
More informationG250/G250 HP Compatibility of Upgrade Kit
Engineering Bulletin December 15, 1999 #266 G250/G250 HP Compatibility of Upgrade Kit Page 1 of 9 The SCUBAPRO G250 HP is a marked improvement on the proven G250 second stage design. So much so that issues
More informationApeks T20 First St age Service & Repair Manual. for Authorized Sea Quest Service Centers Sea Quest, Inc.
Apeks T20 First St age Service & Repair Manual for Authorized Sea Quest Service Centers 2000 Sea Quest, Inc. Contents Introduction... 3 Safety Precautions... 3 General Procedures... 3 Maintenance Schedules...
More informationAUTHORIZED TECHNICIAN TECHNICAL MAINTENANCE MANUAL CALYPSO FIRST STAGE
AUTHORIZED TECHNICIAN TECHNICAL MAINTENANCE MANUAL CALYPSO FIRST STAGE Contents Copyright notice...3 Introduction...3 Warnings, Cautions, & Notes...3 Scheduled Service...3 General Guidelines...3 General
More informationBooster Pump PB4-60 Replacement Kits
Booster Pump PB4-60 Replacement Kits FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product
More informationCONSHELF XIV TECHNICAL MANUAL
CONSHELF XIV TECHNICAL MANUAL Rev. 3/17 2 Conshelf XIV Technical Manual COPYRIGHT NOTICE This manual is copyrighted, all rights reserved. It may not, in whole or in part, be copied, photocopied, reproduced,
More informationRS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.
RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to
More informationLOW PRESSURE INFLATION SYSTEM (LPIS) DRY SUIT INFLATION SYSTEM (DSIS) TECHNICAL MANUAL
LOW PRESSURE INFLATION SYSTEM (LPIS) DRY SUIT INFLATION SYSTEM (DSIS) TECHNICAL MANUAL Rev. 6/17 2 LPIS / DSIS Technical Manual COPYRIGHT NOTICE This manual is copyrighted, all rights reserved. It may
More informationSERVICE MANUAL LEGEND FIRST STAGE
SERVICE MANUAL LEGEND FIRST STAGE Copyright 2005 Aqualung France Rev. 02/2005 2 Legend First Stage Service Manual Index COPYRIGHT... 3 INTRODUCTION... 3 WARNINGS, ATTENTION, NOTE...... 3 MAINTENANCE...
More informationThe Envoy. Regulator Service Manual. For Zeagle Envoy 1st and 2nd Stage Scuba Regulators
The Envoy Regulator Service Manual For Zeagle Envoy 1st and 2nd Stage Scuba Regulators Envoy 1st Stage Parts ITEM # PART # DESCRIPTION... 3 341-0152-AA Label 5 341-0103-CD Spring Adjuster 6 341-0102-CD
More informationLRS(H)4 Pressure-Reducing Regulator User Manual
LRS(H)4 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be considered
More informationService and Repair Operative Manual MC9 1 st STAGE. MC9 1 st Stage. 1 st STAGE MC9. Jannuary Rev. MC9 /B Ed. C/13
MC9 1 st Stage 137 1 st STAGE MC9 Jannuary 2009 - Rev. MC9 /B Ed. C/13 138 WARNING! This manual is intended for use by expert technicians who should attend or have already received training in equipment
More informationRG3100 and RG3100Ice Regulator System
RG3100 and RG3100Ice Regulator System User Guide www.diverite.com Date of purchase: www.diverite.com RG1208-5 & RG1208-5Ice www.diverite.com First Stage Regulator Product Description The RG1208-5 and RG1208-5Ice
More informationPressure Dump Valve Service Kit for Series 2300 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit
More informationR5 Tec Black DIN / Yoke 1 st Stage Service and Repair Manual
R5 Tec Black DIN / Yoke 1 st Stage Service and Repair Manual Version 1.1, May 1, 2014 Disclaimer This document is proprietary to Scubatech Sp. z o. o. ("Scubatech") and no ownership rights are hereby transferred.
More informationSHERWOOD OWNER S MANUAL
SHERWOOD OWNER S MANUAL Thank you for choosing Sherwood Regulators. To get the most satisfying use of this product, please take time to read this entire manual to understand the use and limitations of
More informationKIRBY MORGAN SUPERFLOW REGULATOR OPERATIONS AND MAINTENANCE MANUAL
KIRBY MORGAN SUPERFLOW REGULATOR OPERATIONS AND MAINTENANCE MANUAL Manual Prepared by Dive Lab, Inc. Copyright 2003, Dive Lab, Inc. All Rights Reserved TABLE OF CONTENTS 2 SECTION 1.0 GENERAL INFORMATION
More informationProduct Information News September 26, 2003
Product Information News September 26, 2003 LEVER HEIGHT INSPECTION FOR FIREHAWK MMR MSA is announcing a revision to the instructions for the Firehawk MMR Second Stage Regulator as they relate to the air
More informationRD(H)20/25 Pressure-Reducing Regulator User Manual
RD(H)20/25 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be
More informationAssembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &
REDQ Regulators Model 411B Barstock Design Powreactor Dome Regulator OPERATION AND MAINTENANCE Contents Scope..............................1 Installation..........................1 General Description....................1
More informationLIQUIP DRYBREAK COUPLER. API800 Series MAINTENANCE INSTRUCTIONS
LIQUIP DRYBREAK COUPLER API800 Series MAINTENANCE INSTRUCTIONS API LOADING COUPLER TO API RP1004 June 2015 Issue: F M:\Product-Info\API8xx\6-Service-Maintenance\API800 MAINTENANCE INSTRUCTIONS 40183.doc
More informationHydraulic Piston Accumulators
Ride Control Engineering Services PWCE Extendavator Paul Wever Construction Equipment Co., Inc. P.O. Box 85 401 Martin Drive Goodfield, IL 61742-0085 Phone (309) 965-2005 Fax (309) 965-2905 1-800-990-PWCE
More informationInstallation Troubleshooting Maintenance Instructions Installation / Start-up
Model ZW207 Installation Troubleshooting Maintenance Instructions Installation / Start-up NOTE: Flushing of all pipe lines is to be performed to remove all debris prior to installing valve. 1. For making
More informationDRAFT 12/17/03 KMB 18/28 (BANDMASK) OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A
KMB 18/28 (BANDMASK) OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A2.1 12-17-03 THIS INSPECTION AND MAINTENANCE MUST BE PERFORMED AT LEAST ANNUALLY AND AS DICTATED BY CONDITION REVEALED DURING
More informationFIRST AND SECOND STAGE REGULATORS TECHNICAL SERVICE PROCEDURES
FIRST AND SECOND STAGE REGULATORS TECHNICAL SERVICE PROCEDURES Note: These instructions and schematics are intended for use by qualified regulator repair technicians. They are intended to supplement, not
More informationProduct Information News
Product Information News MMR SECOND STAGE REGULATOR VALVE CORE MSA has changed its recommended rebuilding of the MMR Second Stage Regulator s bypass sleeve assembly during the annual inspection. Based
More information5 Gallon Pressure Pot with HVLP Spray Gun and Hose
California Air Tools 5 Gallon Pressure Pot with HVLP Spray Gun and Hose Model No. 365 Technical Data Type of feed.pressure Maximum pressure in the tank... 0,413Mpa (60PSI) Working pressure in the tank.0,
More informationHelium-Oxygen Blender
Helium-Oxygen Blender Service Manual Model No. PM5400 Series PM5500 Series (shown) SAVE THESE INSTRUCTIONS 300 Held Drive Tel: (+001) 610-262-6090 Northampton, PA 18067 USA Fax: (+001) 610-262-6080 www.precisionmedical.com
More informationPR4 Installation, Operation & Maintenance Instructions (DOT Certification Included)
PR4 Installation, Operation & Maintenance Instructions (DOT Certification Included) March 2006 Form FVC 054 Rev. 6 KEEP THIS DOCUMENT WITH THE PRODUCT UNTIL IT REACHES THE END USER. The Passive - R4 device
More informationDM-MARD (English) Dealer's Manual. ROAD MTB Trekking. City Touring/ Comfort Bike REAR DERAILLEUR XTR RD-M9100 RD-M9120
(English) DM-MARD001-00 Dealer's Manual ROAD MTB Trekking City Touring/ Comfort Bike URBAN SPORT E-BIKE REAR DERAILLEUR XTR RD-M9100 RD-M9120 CONTENTS CONTENTS...2 IMPORTANT NOTICE...3 TO ENSURE SAFETY...4
More informationCleaning rod: spring steel, stainless steel or carbon fibre cleaning rod - only use a one-piece rod. Avoid using snakes.
Telemark Biathlon Where performance and precision come together http://telemarkbiathlon.com Rifle Cleaning Date : July 19, 2013 Anschutz Rifle Manual - Click Here Izhmash 7-3 Rifle Manual - still looking
More informationSCUBAPRO. Balanced Power Inflator
SCUBAPRO Balanced Power Inflator USE THIS GUIDE AS A REFERENCE WHEN SERVICING THE BALANCED POWER INFLATOR Important note: The following information is not designed to be a complete training guide for servicing
More informationHydraulic Punch Drivers
SERVICE MANUAL 7804SB / 7806SB Quick Draw 7704SB / 7706SB Quick Draw Flex Quick Draw Hydraulic Punch Drivers Serial Codes AHJ and YZ Read and understand all of the instructions and safety information in
More informationPRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.
PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to
More informationEASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:
2 Table Of Contents 1. Introduction 3 2. About this Manual 3 3. Contacting YZ Systems 3 4. Vessel Components 4 5. Specifications 5 6. Application 6 7. Theory of Operation 7 8. DuraSite Installation & Use
More informationREGULATORS OMEGA II SECOND STAGE TROUBLE SHOOTING SYMPTOM POSSIBLE CAUSE TREATMENT
TOUBLE SHOOTING SYMPTOM POSSIBLE CAUSE TEATMENT * Freeflow 1. Incorrectly positioned during water entry. 2. Second stage adjusted too sensitively. 3. Excessive intermediate pressure from first stage. 4.
More informationAir-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)
Service Manual Model No. PM5200 Series PM5300 Series (shown) SAVE THESE INSTRUCTIONS 300 Held Drive Tel: (+001) 610-262-6090 Northampton, PA 18067 USA Fax: (+001) 610-262-6080 www.precisionmedical.com
More informationInstallation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual Welker Probe Instrument Regulator Model The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for
More informationDeep Six Signature Regulator Technician Service Manual
Deep Six Signature Regulator Technician Service Manual Copyright 2017 Deep Six Expedition Dive Gear Author UDM Consulting All rights reserved. DEDICATION This manual is dedicated to those who choose to
More informationThermo Valves Corporation
Scuba Diving Valves Maintenance Manual The Leader in High Pressure Technology Date: 07/31/05 Thermo Scuba Products are Sold Through Authorized Distributors Only Thermo PRO Thermo Modular This document
More information600 / 600FC OWNER'S MANUAL
PROGRESSION 600 / 600FC OWNER'S MANUAL Issue 2 / Version E - Dec. 10, 1997 Copyright 1997 GAMMA Sports - All Rights Reserved PROGRESSION 600 / 600FC OWNER'S MANUAL TABLE OF CONTENTS PAGE 1... WARRANTY
More informationDM-RD (English) Dealer s Manual. ROAD Rear Derailleur RD-9000 RD-6800 RD-5800 RD-4700
(English) DM-RD0003-09 ROAD Rear Derailleur Dealer s Manual RD-9000 RD-6800 RD-5800 RD-4700 CONTENTS IMPORTANT NOTICE...3 TO ENSURE SAFETY...4 LIST OF TOOLS TO BE USED...6 INSTALLATION...8 Chain length...
More informationPressure Dump Valve Service Kit for Series 3000 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 000 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00, 400, 500, and 700 applicator
More informationGS2000. (Part Number GR050) Second Stage SERVICE & REPAIR GUIDE
GS2000 (Part Number GR050) Second Stage SERVICE & REPAIR GUIDE Contents Introduction... 3 About This Manual...3 Scheduled Service... 3 EAN/ Nitrox Service... 3 Use of Warnings, Cautions, & Notes... 3 Function
More informationKMB 18/28 (BANDMASK) OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A
KMB 18/28 (BANDMASK) OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A2.1 01-31-17 THIS INSPECTION AND MAINTENANCE SHOULD BE PERFORMED AT LEAST ANNUALLY AND AS DICTATED BY CONDITION REVEALED DURING
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE MODELS RV-1 RV-2 RV-2CP RV-3 DRAWING NUMBERS AD017A[ ] AD018A[ ] AD020A[ ] AD282BO MANUAL NUMBER IOM-033 REVISION Rev. E, 3/28/2016 TABLE
More informationApollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual
I854000.D Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual Introduction This manual presents guidelines for the Installation, Operation and
More informationRG1200 Regulator System
RG1200 Regulator System UserGuide Date of purchase: www.diverite.com DEVELOPED BY COPYRIGHT NOTICE WARRANTY INFORMATION Dive Rite 175 NW Washington Street Lake City, FL 32055 Phone: 386.752.1087 Fax:
More informationAnti-flood device Model B-1
December 4, 2009 Dry Systems 123a 1. DESCRIPTION The Anti-flood Device is required when Viking accelerators are installed on dry systems according to Viking Model E-1 Accelerator Trim Charts. In the SET
More informationTX SECOND STAGE REGULATOR
TECHNICAL SUPPORT TX SECOND STAGE REGULATOR MAINTENANCE MANUAL FOR AUTHORISED TECHNICIANS Document No. AP5833 Issue 1 6/06/2006 APEKS MARINE EQUIPMENT LTD, NEPTUNE WAY, BLACKBURN, LANCASHIRE. BB1 2BT Tel:
More informationCombination Breathing Apparatus
and Combination Breathing Apparatus ULTRAVUE FACEPIECE TAL 502 (L) Rev. 0 MSA 2005 Prnt. Spec. 10000005389 (I) Mat. 10064385 Doc. 10064385 ULTRAVUE FACEPIECE COMPONENTS Item Part No. Description 800509
More informationService & Repair Manual
Powerline Inflator (With Dual Valve) Service & Repair Manual for Authorized Sea Quest Service Centers Doc. No. 42983 1999 Sea Quest, Inc. 2 Sea Quest Powerline Service and Repair Manual Contents Introduction...
More informationSHERWOOD PRO OWNER S MANUAL
SHERWOOD PRO OWNER S MANUAL Blizzard Pro Regulator SRB9950 PRE-DIVE DIVE Side View Thank you for choosing Sherwood Regulators. To get the most satisfying use of this product, please take time to read this
More informationTECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION
Page 1 of 6 1. DESCRIPTION The Model B-1 Anti-flood Device is required when Viking accelerators are installed on dry systems according to Viking Model E-1 Accelerator Trim Charts. In the SET condition,
More information8. Carefully layout all the parts of the reservoir setup and clean any dirt, grime or dust from the parts. ( image 8 ) 8
INSTRUCTIONS TO SERVICE AMADAXTREME SHOCKS 2.0 REMOTE RES AUSTRALIAN VERSION PART 1 - SERVICE THE RESERVOIR 1.Prior to cleaning the shock check for any leaks or signs of damage to the res, lines, bushes
More informationLOW PROFILE AUTO DUMP VALVE
TECHNICAL SUPPORT LOW PROFILE AUTO DUMP VALVE MAINTENANCE MANUAL FOR AUTHORISED TECHNICIANS Document No. AP 5921 Issue 2 09/11/06 APEKS MARINE EQUIPMENT LTD, NEPTUNE WAY, BLACKBURN, LANCASHIRE. BB1 2BT
More informationMMR Air Mask With. with Quick-Connect Hose
MMR Air Mask With with Quick-Connect Hose Upgrade Kits P/N 10025120 Slide to Connect P/N 10050038 Slide to Connect w/ Solid Cover P/N 10038666 Push To Connect P/N 10050037 Push To Connect w/ Solid Cover
More informationIMPORTANT: RECEIVING INSTRUCTIONS:
Instruction Sheet Sidewinder Mechanical Bender IMPORTANT: RECEIVING INSTRUCTIONS: Visually inspect all components for shipping damage. If any shipping damage is found, notify carrier at once.shipping damage
More informationREGULATORS (SRB3600) Assembly & Maintenance Guide
REGULATORS (SRB3600) Assembly & Maintenance Guide FIRST STAGE - MAXIMUS SRB3600 ITEM # CATALOG # DESCRIPTION............SRB3601........First Stage Complete 1...........5105-70.........Handwheel Assembly
More informationModel 23H Hand Crank Seamer
OPERATOR'S MANUAL Model 23H Hand Crank Seamer If you are not experienced with your seamer, please read and understand this manual before operating the machine. If you have a question discuss it with your
More informationAir Mask Low/High Pressure
Air Mask Low/High Pressure USERS MAINTENANCE INSTRUCTIONS THIS MANUAL MUST BE CAREFULLY READ AND FOLLOWED BY ALL PERSONS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR USING OR SERVICING THIS AIR MASK. This
More informationRepair instructions. Pivot bushing replacement. XL-AS10001RM-en-DE Rev B
Repair instructions Pivot bushing replacement XL-AS10001RM-en-DE Rev B Table of contents Table of contents 1 General information... 3 1.1 Safety information...3 1.2 Legal information...4 1.3 Order and
More informationPROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road
PROPORTIONING VALVE Model 150 INSTRUCTION MANUAL March 2017 IMS Company 10373 Stafford Road Telephone: (440) 543-1615 Fax: (440) 543-1069 Email: sales@imscompany.com 1 Introduction IMS Company reserves
More informationMAGNETIC INDOOR CYCLING BIKE
MAGNETIC INDOOR CYCLING BIKE SF-B1805 USER MANUAL IMPORTANT! Please retain owner s manual for maintenance and adjustment instructions. Your satisfaction is very important to us, PLEASE DO NOT RETURN UNTIL
More information44in Side Discharge Mower for Wheel Horse XL 440H Lawn Tractors Model No Serial No and Up
Form No. 5-8 in Side Discharge Mower for Wheel Horse XL 0H Lawn Tractors Model No. 790 Serial No. 5000000 and Up Operator s Manual Register your product at www.toro.com Original Instructions (EN) Contents
More informationWELLS JOHNSON HIGH VOLUME CANISTERS
WELLS JOHNSON HIGH VOLUME CANISTERS USER MANUAL DISASSEMBLY OF HARVESTING CANISTERS Please follow the instructions provided to disassemble 5L, 3L, 2L, and 1L, 250mL and 500mL harvesting canisters. 1. Unscrew
More informationDM-MBRD (English) Dealer's Manual. ROAD MTB Trekking. City Touring/ Comfort Bike. Rear Derailleur SLX RD-M7000 DEORE RD-M6000
(English) DM-MBRD001-04 Dealer's Manual ROAD MTB Trekking City Touring/ Comfort Bike URBAN SPORT E-BIKE Rear Derailleur SLX RD-M7000 DEORE RD-M6000 CONTENTS IMPORTANT NOTICE... 3 TO ENSURE SAFETY... 4
More informationTable of Contents. Operating Instructions. Resource v.2 Conserving Regulator
Operating Instructions Table of Contents Resource v.2 Conserving Regulator Safety Information Device Precautions Introduction Product Features Product Specifications Feature Illustrations Set Up Usage
More informationCS150 CAP STAPLER OWNER S MANUAL
Operation Revised 6/2013 www.stingerworld.com CS150 CAP STAPLER OWNER S MANUAL! Maintenance Safety Warranty PLEASE READ! This manual contains important information about product safety. WELCOME TO STINGER
More informationLRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.
LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the
More informationInstallation of Your SprayMaster System
Installation of Your SprayMaster System 1. At the installation site, remove all equipment from the corrugated box and the polyethylene drum and replace the drum lid. Check the picture to identify each
More informationKMB 18/28 (BANDMASK) MONTHLY MASK INSPECTION APPENDIX A
KMB 18/28 (BANDMASK) MONTHLY MASK INSPECTION APPENDIX A2.2 08-01-17 This inspection is the minimum recommended maintenance and should be performed at least ONCE A MONTH with Mask(s) in continuous use (used
More informationTECHNICAL MAINTENANCE MANUAL POWERLINE INFLATOR
TECHNICAL MAINTENANCE MANUAL POWERLINE INFLATOR 2 CHANGE RECORD PAGE # REV. DATE TITLE OR DESCRIPTION CHANGE MADE BY 9/15/18 11/20/14 Change oral rod torque Spec to 6.5 in-lbs (0.75 Nm) Aqua Lung USA Powerline
More informationSALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS
STORAGE INSTRUCTIONS Until it is time to install a new or reconditioned valve on the car, the valve must be kept in its original packaging in order to protect it from dirt and damage. INSTALLATION INSTRUCTIONS
More informationKIRBY MORGAN DEEP SEA DIVING HELMETS ALL MODELS OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A
KIRBY MORGAN DEEP SEA DIVING HELMETS ALL MODELS OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A2.1 9-22-15 THIS INSPECTION AND MAINTENANCE SHOULD BE PERFORMED AT LEAST ANNUALLY AND AS DICTATED
More informationInstallation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual Welker The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for the installation, operation, and
More informationREL-510H WARNING NOTICE 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD
OPERATORS ORS GUIDE REL-510H 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD Compatible with U style and RELIABLE R12 shell type 12 ton compression dies. RELIABLE EQUIPMENT & SERVICE CO., INC. 92 Steamwhistle
More information