Contamination Removal of EUVL masks and optics using 13.5-nm and 172-nm radiation

Size: px
Start display at page:

Download "Contamination Removal of EUVL masks and optics using 13.5-nm and 172-nm radiation"

Transcription

1 Contamination Removal of EUVL masks and optics using 13.5-nm and 172-nm radiation Takeo Watanabe, Kazuhiro Hamamoto and Hiroo Kinoshita University of Hyogo IEUVI Resist & Contamination TWG Oct.19, 2006 in Barcelona

2 Method of contamination removal (1) Cleaning of EUVL imaging optics (The optics used for EUVL has been aligned in high accuracy. So the cleaning of imaging optics requires in-situ process.) In-situ contamination removal by synchrotron radiation without heating (2) Cleaning of EUVL masks (Both large cleaning area and high speed are required.) Contamination removal by 172-nm-wavelength. Evaluation between before and after removal Contamination thickness Optical thickness measuring system Surface roughness AFM Reflectivity Reflectometer (NewSUBARU BL-10)

3 Online contamination removal by a wavelength of 13.5 nm

4 Contamination adhesion in ETS-1 exposure system M1 M3 M2 Mask Wafer Partial pressure (Pa) Partial pressure in ETS-1 H 2 O N 2 CO C x H y 2 Sample of the multilayer is set on the mask stage, and EUV is irradiated Mass number Total pressure: Pa

5 Thickness of contamination Thickness of contamination (nm) Electron beam current: 200 ma Irradiation time (min.) Deposition rate: 7.5 nm/hr (0.125 nm/min)

6 Reflectivity of multilayer Reflectivity Irradiation time (min.) Multilayer reflectivity of 10% decreased by 4 hours irradiation

7 Surface roughness of multilayer Surface roughness (nm) Irradiation time (min.)

8 Photoelectron intensity for Ta (cps. ev) AES spectrum of contamination of mask O C Ta Photoelectron intensity for C, O, Si (cps. ev) Sputtering time (min.) The ratio of C to O is 96:4

9 Experimental setup of SR cleaning Storage ring M2 mirror M3 mirror (Branch) ETS-1 M1 mirror Photodiode (GaAsP) Contamination testing chamber Incident angle 10 SR Back pressure: Pa adding O 2 during Mask sample TMP Oxygen SR irradiation pressure: Pa

10 Experimental results Normalized reflectivity Normalized storage ring current Pressure: Pa Electron beam current: 130 ma Irradiation: 7 hr Time (min.) Contamination of 0.1-µm-thick was removed. Before cleaning After cleaning

11 Reduction of contamination thickness Reduction in thickness (nm) Removal rate: 0.24 nm/min 7 hr 0 0 1x10 6 2x10 6 3x10 6 4x10 6 5x10 6 6x10 6 7x10 6 8x10 6 Exposure dose (mas) Electron beam current: 130 ma

12 Reflectivity of multilayer (measurement: NS-BL10) Before cleaning contamination multilayer absorber A B C D E After cleaning absorber multilayer absorber Reflectivity E D C B A Reflectivity Wavelength (nm) Wavelength (nm)

13 Offline contamination removal by a wavelength of 172 nm

14 Mask cleaning using 172 nm-excimer VUV/O 3 CO x, H 2,CH z,h 2 O, 172 nm ozone(o 3 ) oxygen(o 2 ) C x H y Active oxygen species(o*) Mo/Si contamination The absorption coefficient to the oxygen molecule at the wavelength of 172 nm is 20 times larger than that at the wavelength of 185 nm of the low-pressure mercury lamp. A high density active oxygen species can be generated.

15 Experimental setup of 172 nm cleaning 172 nm excimer lamp 1mm Stage Intensity 20 mw/cm 2 Distance 1 mm Sample size 8-inch Temperature 25 Environment in the air / in O 2 -rich vacuum O 2 -rich vacuum environment: The initial back pressure of the chamber was 500 Pa by scroll pump, and an O 2 flow kept the pressure at Pa.

16 Results of mask cleaning using 172 nm-excimer lamp (1) Reduction of contamination thickness 30 Removal thickness (nm) in vacuum rate: 2 nm/min. in the air rate: 0.53 nm/min Cleaning time (min)

17 Results of mask cleaning using 172 nm-excimer lamp (2) Reflectivity of multilayer 70% Reflectivity 60% 50% 40% 30% 20% 10% After cleaning Before cleaning 0% Wavelength (nm)

18 Summary (1) From the result of AES, it has been understood that the element of contamination is almost carbon. (2) The effectiveness of the contamination removal for EUVL imaging optics using both in-situ and non-heating method by EUV irradiation in the oxygen atmosphere is confirmed. (3) The effectiveness of the contamination removal for the finished EUVL mask in off-line process using the 172 nmexcimer lamp in the O 2 -rich vacuum atmosphere at the room temperature is confirmed.

19 Thank you for your attention!!

20 Outgassing Measurement in University of Hyogo -Short summary- Takeo Watanabe, Hiroo Kinoshita University of Hyogo IEUVI Resist & Contamination TWG Oct.19, 2006 in Barcelona

21 Setup of novel resist evaluation system 1) Measurements of sensitivity 2) Outgas characteristics 3) Chemical reaction analysis Mo/Si MLs Concave Mirror Simulating six-mirror optics Practical exposure spectrum PC controlled fast speed shutter ( t=11 ms) SR High-sensitive ion counting type Q-mass spectrometer Model HAL/3F/PIC 501 RC, Hiden Analytical, Ltd. Distance 30 mm Mo/Si MLs Two Plane Mirrors Sample

22 Setup of novel resist evaluation system Gate valve Shutter chamber SR Differential pumping Sample Mirror chamber TMP 700L/s Gate valve Gate valve Sample chamber TMP 300L/s Loadlock chamber TMP 300L/s Sample insertion rod

23 By Takeo Watanabe, Univ. of Hyogo 2006 Oct 19 Institute Method Results Molecules/cm mj/cm 2 dose Molecules/cm 2 intensity condition Estimate Rate Molecules/cm 2 Tool (0.4 W/cm 2 ) Intel Synchrotron GC/MS mw/cm SEMATECH Synchrotron GC/MS mw/cm amu ASET Synchrotron Online QMS mw/cm amu BOC Edwards Stand-alone source Online QMS mw/cm 2??-??? amu Univ. of Hyogo Synchrotron Online QMS mw/cm amu amu amu amu amu Excluding 44 amu amu Excluding 44 amu amu Excluding 44 amu

Resist Outgassing and its Role in Optics Contamination

Resist Outgassing and its Role in Optics Contamination Resist Outgassing and its Role in Optics Contamination Gregory Denbeaux, Rashi Garg, Kim Dean* College of Nanoscale Science and Engineering University at Albany *SEMATECH, Austin, TX Advanced Materials

More information

Resist round robin ELETTRA

Resist round robin ELETTRA Resist round robin outgassing @ ELETTRA Trieste - Italy M. Bertolo, P. Lacovig, L.Rumiz, D. Giuressi, R. Sergo, A. Stolfa Experimental setup (1) 100 mm linear translator Sample manipulator Mask manipulator

More information

EUVL Optics Contamination from Resist Outgassing; Status Overview

EUVL Optics Contamination from Resist Outgassing; Status Overview Accelerating the next technology revolution EUVL Optics Contamination from Resist Outgassing; Status Overview Kevin Orvek 1, Greg Denbeaux 2, Alin Antohe 2, Rashi Garg 2, Chimaobi Mbanaso 2 1 SEMATECH

More information

Ionic outgassing from photoresist compositions upon irradiation at 13.5 nm

Ionic outgassing from photoresist compositions upon irradiation at 13.5 nm Ionic outgassing from photoresist compositions upon irradiation at 13.5 nm Grace H. Ho, Chih- Jen Liu, Chih- Han Yen, Ming- Hsuan Ho, Shih-Yu Wu, and Yu-Hsian Shih Department of Applied Chemistry National

More information

Outgas Testing Update on EUV Light vs. Electron beam

Outgas Testing Update on EUV Light vs. Electron beam Outgas Testing Update on EUV Light vs. Electron beam Toshiya Takahashi, Norihiko Sugie, Kazuhiro Katayama, Isamu Takagi Yukiko Kikuchi, Eishi Shiobara, Hiroyuki Tanaka, Soichi Inoue EUVL Infrastructure

More information

(OBPL: Out of Band Protection Layer) Ryuji Onishi, Rikimaru Sakamoto, Noriaki Fujitani, Takafumi Endo, Bang-ching Ho

(OBPL: Out of Band Protection Layer) Ryuji Onishi, Rikimaru Sakamoto, Noriaki Fujitani, Takafumi Endo, Bang-ching Ho The Novel Top-Coat Material for RLS Trade-off reduction in EUVL (: Out of Band Protection Layer) Ryuji Onishi, Rikimaru Sakamoto, Noriaki Fujitani, Takafumi Endo, Bang-ching Ho Semiconductor Materials

More information

Performances of fluoropolymer resists for 157-nm lithography

Performances of fluoropolymer resists for 157-nm lithography 1 Performances of fluoropolymer resists for 157-nm lithography Seiichi Ishikawa, Naomi Shida, Tamio Yamazaki, Hiroyuki Watanabe, Seiro Miyoshi, Takamitsu Furukawa, Minoru Toriumi and Toshiro Itani Contents

More information

Outgas of Methane from NEG Coating

Outgas of Methane from NEG Coating WS63: SURFACE PHENOMENA LIMITING PRESSURE IN VACUUM SYSTEM Outgas of Methane from NEG Coating Chia-Mu Cheng ( 鄭家沐 ) Vacuum Group NSRRC, Taiwan 18 /09/2010 e-mail : chiamucheng@nsrrc.org.tw 1 Application

More information

EUV Resist Performance under High Stray Light Levels: an Interference Lithography Study

EUV Resist Performance under High Stray Light Levels: an Interference Lithography Study EUV Resist Performance under High Stray Light Levels: an Interference Lithography Study Roel Gronheid 1, Alan M. Myers 1,2, Frieda Van Roey 1, Harun H. Solak 3, Yasin Ekinci 3, Tom Vandeweyer 1, Anne-Marie

More information

A NOVEL SENSOR USING REMOTE PLASMA EMISSION SPECTROSCOPY FOR MONITORING AND CONTROL OF VACUUM WEB COATING PROCESSES

A NOVEL SENSOR USING REMOTE PLASMA EMISSION SPECTROSCOPY FOR MONITORING AND CONTROL OF VACUUM WEB COATING PROCESSES A NOVEL SENSOR USING REMOTE PLASMA EMISSION SPECTROSCOPY FOR MONITORING AND CONTROL OF VACUUM WEB COATING PROCESSES F. Papa 1, J. Brindley 2, T. Williams 2, B. Daniel 2, V. Bellido-Gonzalez 2, Dermot Monaghan

More information

Outgassing, photoablation and photoionization of organic materials by the electron-impact and photon-impact methods

Outgassing, photoablation and photoionization of organic materials by the electron-impact and photon-impact methods Outgassing, photoablation and photoionization of organic materials by the electron-impact and photon-impact methods Grace H. Ho*, Yen-H. Huang, Hung-M. Lin, Chih-H. Shao, Chen-Y. Yeh, and Jia-J. Sung Department

More information

Thermo K-Alpha XPS Standard Operating Procedure

Thermo K-Alpha XPS Standard Operating Procedure Thermo K-Alpha XPS Standard Operating Procedure Quick Guide Draft v.0.1 Procedure overview 1. Vent the loadlock 2. Secure your sample to the stage using clips, check the height of the final assembly. 3.

More information

Our Approaches to EUV Resist Materials. N. Ohshima ELECTRONIC MATERIALS RESEARCH LABORATORIES RESEARCH & DEVELOPMENT MANAGEMENT HEADQUARTERS

Our Approaches to EUV Resist Materials. N. Ohshima ELECTRONIC MATERIALS RESEARCH LABORATORIES RESEARCH & DEVELOPMENT MANAGEMENT HEADQUARTERS Our Approaches to EUV Resist Materials N. Ohshima ELECTRONIC MATERIALS RESEARCH LABORATORIES RESEARCH & DEVELOPMENT MANAGEMENT HEADQUARTERS Page 1 June 2008 Outline 1. Challenges to EUV Resist Materials

More information

Plasma Sources and Feedback Control in Pretreatment Web Coating Applications

Plasma Sources and Feedback Control in Pretreatment Web Coating Applications Plasma Sources and Feedback Control in Pretreatment Web Coating Applications Joseph Brindley, Benoit Daniel, Victor Bellido-Gonzalez, Dermot Monaghan Gencoa Ltd., Physics Rd, L24 9HP Liverpool, UK (+44)

More information

Practical approach and problems in in-situ RGA calibration

Practical approach and problems in in-situ RGA calibration Practical approach and problems in in-situ RGA calibration Oleg Malyshev and Keith Middleman Vacuum Science Group, ASTeC Accelerator Science and Technology Centre STFC Daresbury Laboratory UK Workshop

More information

Karl Suss MJB4 Mask Aligner

Karl Suss MJB4 Mask Aligner Karl Suss MJB4 Mask Aligner Tool Manager: Yong Sun ( yongs@princeton.edu; Office 8-8234; Cell 609-917-5076 ) Backup: George Watson ( gwatson@princeton.edu; Office 8-4626; Cell 732-996-2713 ) ******************************************************************************

More information

A decade of EUV resist outgas tes2ng Lessons learned. C. Tarrio, S. B. Hill, R. F. Berg, T. B. Lucatorto NIST, Gaithersburg, MD, USA

A decade of EUV resist outgas tes2ng Lessons learned. C. Tarrio, S. B. Hill, R. F. Berg, T. B. Lucatorto NIST, Gaithersburg, MD, USA A decade of EUV resist outgas tes2ng Lessons learned C. Tarrio, S. B. Hill, R. F. Berg, T. B. Lucatorto NIST, Gaithersburg, MD, USA Outline A lihle history Recent round- robin witness- sample tes2ng results

More information

The Principles of Vacuum Technology

The Principles of Vacuum Technology The Principles of Vacuum Technology Vacuum Terminology Vacuum units Vacuum regimes How to measure vacuum. Gauge designs. How to create vacuum Pump classifications and designs UHV compatibility considerations

More information

Selection of Materials and Processes for Space Use. Ruben Edeson, Mechanical Engineer, SSTD.

Selection of Materials and Processes for Space Use. Ruben Edeson, Mechanical Engineer, SSTD. Selection of Materials and Processes for Space Use Ruben Edeson, Mechanical Engineer, SSTD. Materials Selection for Space Mechanical properties, ie specific stiffness Thermal and optical properties Cost

More information

SINGULUS TECHNOLOGIES

SINGULUS TECHNOLOGIES Fast Vacuum for Optical Disc Metallization and Photovoltaic Coatings B. Cord, M. Hoffmann, O. Hohn, F. Martin SINGULUS Technologies AG, Kahl am Main SINGULUS TECHNOLOGIES June 2014 SINGULUS Overview 25-June-2014-2

More information

Outline. 1. Design of the cerl Vacuum System. 2. Layout of the Vacuum Components

Outline. 1. Design of the cerl Vacuum System. 2. Layout of the Vacuum Components Outline 1. Design of the cerl Vacuum System 2. Layout of the Vacuum Components 3. Summary of the Progress 1. Design of the cerl Vacuum System cerl Vacuum System σ Dipole Chamber A Laser Alignment Port

More information

SPINE workshop Uppsala, Sweden, Jan 17-19, 2011 Spacecraft outgassing: Rosetta results

SPINE workshop Uppsala, Sweden, Jan 17-19, 2011 Spacecraft outgassing: Rosetta results SPINE workshop Uppsala, Sweden, Jan 17-19, 2011 Spacecraft outgassing: Rosetta results B. Schläppi, K. Altwegg, H. Balsiger, M. Hässig, A. Jäckel, P. Wurz, B. Fiethe, M. Rubin, S. A. Fuselier, J. J. Berthelier,

More information

R I T. Title: Amray 1830 SEM Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 09/29/03 1 SCOPE 2 REFERENCE DOCUMENTS

R I T. Title: Amray 1830 SEM Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 09/29/03 1 SCOPE 2 REFERENCE DOCUMENTS Fabrication Laboratory Revision: A Rev Date: 09/29/03 Approved by: Process Engineer / / / / Equipment Engineer 1 SCOPE The purpose of this document is to detail the use of the Amray 1830 SEM. All users

More information

Improved Sputter Depth Resolution in Auger Thin Film Analysis Using In Situ Low Angle Cross-Sections

Improved Sputter Depth Resolution in Auger Thin Film Analysis Using In Situ Low Angle Cross-Sections Improved Sputter Depth Resolution in Auger Thin Film Analysis Using In Situ Low Angle Cross-Sections Uwe Scheithauer SIEMENS AG, ZT MF 7, Otto-Hahn-Ring 6, 81730 München, Germany Phone: + 49 89 636-44143,

More information

MJB4 Mask Aligner Operating Procedure. Effective Date: 07/12/2012 Author(s): Jiong Hua Phone:

MJB4 Mask Aligner Operating Procedure. Effective Date: 07/12/2012 Author(s): Jiong Hua Phone: MJB4 Mask Aligner Operating Procedure Effective Date: 07/12/2012 Author(s): Jiong Hua Phone: 402-472-3773 Email: jhua2@unl.edu 1 1 Introduction 1.1 Key Words Karl Suss MJB4 Mask Aligner, Optical Lithography,

More information

The use of remote plasma emission spectroscopy as an alternative method of gas sensing for direct monitoring of vacuum processes

The use of remote plasma emission spectroscopy as an alternative method of gas sensing for direct monitoring of vacuum processes Enlighten Conference and Vacuum Symposium 12 th October 2017 The use of remote plasma emission spectroscopy as an alternative method of gas sensing for direct monitoring of vacuum processes Joe Brindley,

More information

Inert Atmosphere Guide

Inert Atmosphere Guide Inert Atmosphere Guide The UV curing of acrylate monomers is a free radical polymerization process in which UV radiation is absorbed and activates a certain type of molecules, photoinitiators. The activated

More information

Usage Policies Notebook for Karl Suss MA6 Mid / Deep UV Mask Aligner

Usage Policies Notebook for Karl Suss MA6 Mid / Deep UV Mask Aligner Usage Policies Notebook for Karl Suss MA6 Mid / Deep UV Mask Aligner Revision date September 2014 2 Emergency Plan for Karl Suss MA6 Aligner Standard Operating Procedures for Emergencies Contact information

More information

Relative Dosimetry. Photons

Relative Dosimetry. Photons Relative Dosimetry Photons What you need to measure! Required Data (Photon) Central Axis Percent Depth Dose Tissue Maximum Ratio Scatter Maximum Ratio Output Factors S c & S cp! S p Beam profiles Wedge

More information

Water for Immersion Lithography

Water for Immersion Lithography Water for Immersion Lithography M. Switkes, V. Liberman, and M. Rothschild Lincoln Laboratory Massachusetts Institute of Technology Lexington, MA 02420 Outline Water treatment The symptoms Differences

More information

EUV Mask Handling Standards

EUV Mask Handling Standards EUV Mask Handling Standards Scott Hector*, SEMATECH Mask Strategy Program Manager November 2004 * On assignment from Freescale Semiconductor, Inc. Acknowledge: Thomas White Outline Standard for mask frame

More information

OSI. Outgassing Measurements on Nonwoven Fabric (H8004) Prepared for:

OSI. Outgassing Measurements on Nonwoven Fabric (H8004) Prepared for: OSI Outgassing Services International 2224-H Old Middlefield Way, Mountain View, CA 94043 USA Phone +1 650 960 1390 Fax +1 650 960 1388 garrett@osilab.com Outgassing Measurements on Nonwoven Fabric (H8004)

More information

Vacuum Science Techniques and Applications Dan Dessau Adv. Lab 2007

Vacuum Science Techniques and Applications Dan Dessau Adv. Lab 2007 Vacuum Science Techniques and Applications Dan Dessau Adv. Lab 2007 Vacuum increases the mean-free-path of gas molecules. Vacuum prevents chemical reaction. Vacuum removes contaminants from surfaces. Vacuum

More information

Introduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project.

Introduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project. Introduction of Vacuum Science & Technology Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project. 1 What is a vacuum? 760 mm Hg Vacuum ATM A vacuum is defined as less than

More information

The Gas Attenuator of FLASH

The Gas Attenuator of FLASH INTRODUCTION The Gas Attenuator of FLASH K. Tiedtke, N. von Bargen, M. Hesse, U. Jastrow, U. Hahn The experimental hall of the FLASH user facility is located approximately 30m behind the last dipole magnet

More information

High Performance Mass Spectrometers

High Performance Mass Spectrometers High Performance Mass Spectrometers For Vacuum and Semiconductor Process Monitoring Detailed product information / introduction MOCVD semiconductor processing Applications: XXCVD/MOCVD XXPECVD XXALD XXSputtering

More information

Residual Gas Analysis Systems for Industry

Residual Gas Analysis Systems for Industry HIDEN RC SYSTEMS QUADRUPOLE MASS SPECTROMETERS FOR RGA, GAS ANALYSIS AND PROCESS MONITORING The HAL RC systems are designed for RGA, gas analysis and process monitoring applications including leak detection,

More information

LCLS Heavy Met Outgassing Tests * K. I. Kishiyama, D. M. Behne Lawrence Livermore National Laboratory

LCLS Heavy Met Outgassing Tests * K. I. Kishiyama, D. M. Behne Lawrence Livermore National Laboratory UCRL-TR-223160 LCLS-TN-06-12 July 12, 2006 LCLS Heavy Met Outgassing Tests * K. I. Kishiyama, D. M. Behne Lawrence Livermore National Laboratory Abstract A Heavy Met that is 95% tungsten, 3% nickel and

More information

Short Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd.

Short Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd. Short Introduction to Cryo-Pumps and Refrigerators Dr Graham Rogers Leybold UK Ltd. Cryo Pumps Topics Physical principles of cryo-pumping Design and control of modern refrigerator cryo-pumps UHV and XHV

More information

Advanced Technology Center. Vacuum Optics. Mark Sullivan December 2, Vacuum Optics 1

Advanced Technology Center. Vacuum Optics. Mark Sullivan December 2, Vacuum Optics 1 Advanced Technology Center Vacuum Optics Mark Sullivan December 2, 2006 Vacuum Optics 1 Outline System design approach Specific steps to build successful vacuum optics ASTM E 1559 outgassing test Resources

More information

Development of Cleaning and Processing Techniques for UHV/XHV at Daresbury Laboratory Keith Middleman

Development of Cleaning and Processing Techniques for UHV/XHV at Daresbury Laboratory Keith Middleman Development of Cleaning and Processing Techniques for UHV/XHV at Daresbury Laboratory Keith Middleman ASTeC Vacuum Science Group STFC Daresbury Laboratory Accelerators + Vacuum Particle accelerators come

More information

XSL-360-5E. UV LED 5 mm TECHNICAL DATA. Absolute Maximum Ratings (T a =25 C) Specifications (If=20mA, T a =25 C) Drawing

XSL-360-5E. UV LED 5 mm TECHNICAL DATA. Absolute Maximum Ratings (T a =25 C) Specifications (If=20mA, T a =25 C) Drawing XSL-360-5E TECHNICAL DATA UV LED 5 mm Drawing Absolute Maximum Ratings (T a =25 C) Item Symbol Value Unit DC Forward Current I F 25 ma Peak Pulse Forward Current * 1 I FP 100 ma Power Dissipation P D 100

More information

Operation of the contact mask aligner Canon PPC 210 Projection Print Camera

Operation of the contact mask aligner Canon PPC 210 Projection Print Camera Operation of the contact mask aligner Canon PPC 210 Projection Print Camera Start-up Procedure: 1. Start the grey pump in the service corridor behind the aligner 2. Open the valve for the Nitrogen gas

More information

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices Oneida Research Services, Inc. 8282 Halsey Road Whitesboro, NY 13492 Phone: (315) 736-5480 FAX: (315) 736-9321 1.0 Purpose The

More information

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION BEST KNOWN METHODS Transpector XPR3 Gas Analysis System DESCRIPTION The Transpector XPR3 is a third-generation, quadrupole-based residual gas analyzer that operates at PVD process pressures and is the

More information

MASSIVE TITANIUM SUBLIMATION PUMPING IN THE CESR INTERACTION REGION *

MASSIVE TITANIUM SUBLIMATION PUMPING IN THE CESR INTERACTION REGION * MASSIVE TITANIUM SUBLIMATION PUMPING IN THE CESR INTERACTION REGION * N.B. Mistry, R. Kersevan and Yulin Li, Laboratory of Nuclear Studies, Cornell University, Ithaca, NY 153 USA Abstract * The residual

More information

Leaks, contamination and closed loop control how RGAs make coating processes more profitable

Leaks, contamination and closed loop control how RGAs make coating processes more profitable Leaks, contamination and closed loop control how RGAs make coating processes more profitable Backup: What s an RGA Residual Gas Analyzer An instrument that is measuring the gas composition in a chamber

More information

Vacuum Simulations of the KATRIN Experiment

Vacuum Simulations of the KATRIN Experiment Vacuum Simulations of the KATRIN Experiment Marcel Krause (KATRIN collaboration) 31.03.2014 KIT University of the State of Baden-Wuerttemberg and National Research Center of the Helmholtz Association www.kit.edu

More information

Hiden QIC Series Gas Analysers Real-time gas analysis systems

Hiden QIC Series Gas Analysers Real-time gas analysis systems Hiden QIC Series Gas Analysers Real-time gas analysis systems vacuum analysis surface science plasma diagnostics gas analysis Application Focussed Options Multistream valves 20, 40 and 80 way versions

More information

KARL SUSS MJB3 MASK ALIGNER STANDARD OPERATING PROCEDURE

KARL SUSS MJB3 MASK ALIGNER STANDARD OPERATING PROCEDURE KARL SUSS MJB3 MASK ALIGNER STANDARD OPERATING PROCEDURE Purpose of this Instrument: This instrument is for patterning photosensitive polymers with UV light. Location: White Hall 410 Cleanroom Primary

More information

Plasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G.

Plasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G. Yamato Scientific America Innovating Science for Over 125 Years Plasma Cleaner Contents Gas Plasma Dry Cleaner PDC200/210/510 PDC610G Gas Plasma Reactor 145 146 147 149 144 Gas Plasma Dry Cleaner Plasma

More information

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Cambridge International Examinations Cambridge International General Certificate of Secondary Education Cambridge International Examinations Cambridge International General Certificate of Secondary Education *8269683414* PHYSICS 0625/31 Paper 3 Extended October/November 2014 1 hour 15 minutes Candidates

More information

Operating Procedures for Metal Evaporator I

Operating Procedures for Metal Evaporator I Operating Procedures for Metal Evaporator I Metal Evaporator I is intended as a tool and a training device. Understanding the operation of this equipment should give you a basic knowledge of vacuum and

More information

Approved by Principal Investigator Date: Approved by Super User: Date:

Approved by Principal Investigator Date: Approved by Super User: Date: Approved by Principal Investigator Date: Approved by Super User: Date: Standard Operating Procedure BNC Commonwealth Dual Ion Beam Deposition System (CDIBS) Version 2010 February 14 I. Purpose This Standard

More information

Standard Operating Manual

Standard Operating Manual Standard Operating Manual AB-M Mask Aligner Version 1.1 Page 1 of 18 Contents 1. Picture and Location 2. Process Capabilities 2.1 Cleanliness Standard 2.2 Wafer Chuck Selection 2.3 Mask Holder Selection

More information

Choosing a Quadrupole Gas Analyzer Application Note #9

Choosing a Quadrupole Gas Analyzer Application Note #9 Choosing a Quadrupole Gas Analyzer Application Note #9 Modern-day contamination control requirements for gas phase processes are constantly pushing the limits of performance of quadrupole gas analyzers.

More information

Chapter 8: Cryo-sorption pumps

Chapter 8: Cryo-sorption pumps Chapter 8: Cryo-sorption pumps Cryo-sorption pumps offer a clean, quiet, safe, vibration free and inexpensive way to rough pump a vacuum system. They are often used on vacuum systems that are sensitive

More information

Karl Suss MA6 Mask Aligner SOP

Karl Suss MA6 Mask Aligner SOP Page 1 of 11 Karl Suss MA6 Mask Aligner SOP Safety UV Exposure: The high energy light produced by the high pressure Mercury Xenon lamp can cause eye damage and skin burns. Be sure that the light guards

More information

Photolithography. Operating Instructions

Photolithography. Operating Instructions Photolithography Operating Instructions The PR used during this laboratory session will be Microposit S1813 (from Shipley). Make sure everyone is following the laboratory protocol. Wear lab coats, safety

More information

Achieving Ultra-High Vacuum without (in-situ) Bakeout

Achieving Ultra-High Vacuum without (in-situ) Bakeout Achieving Ultra-High Vacuum without (in-situ) Bakeout Matthew Cox Diamond Light Source, UK WS 63 Ávila September 2010 1 What is Diamond Light Source? The UK national synchrotron facility 3 rd generation

More information

QUORUM TECH 150RES THE FIRST AND THIRD WEEK WILL BE SET UP FOR CARBON COATING THE SECOND AND LAST WEEK WILL BE SET UP FOR GOLD COATING

QUORUM TECH 150RES THE FIRST AND THIRD WEEK WILL BE SET UP FOR CARBON COATING THE SECOND AND LAST WEEK WILL BE SET UP FOR GOLD COATING QUORUM TECH 150RES This document is intended to describe the function and use of the QuorumTech Q150RES system. Formal training and qualification by staff is required before gaining access to the tool.

More information

Cambridge NanoTech: Savannah S100. Table of Contents

Cambridge NanoTech: Savannah S100. Table of Contents Table of Contents 1.0 Purpose/Scope... 2 2.0 Reference Documents... 2 3.0 Equipment/Supplies/Material... 2 4.0 Safety... 2 5.0 Logbook... 3 6.0 Login and Launch Software... 3 7.0 Session Setup... 3 8.0

More information

Outline. Chapter 11 Treatment Planning Single Beams. Patient dose calculation. Patient dose calculation. Effect of the curved contour surface

Outline. Chapter 11 Treatment Planning Single Beams. Patient dose calculation. Patient dose calculation. Effect of the curved contour surface Chapter 11 reatment Planning Single Beams Radiation Dosimetry I Outline Basic terminology Curved contour surface correction (bolus, compensators, wedges) Oblique beam incidence Correction for tissue inhomogeneities

More information

Graphite and C-C materials for UHV applications

Graphite and C-C materials for UHV applications Graphite and C-C materials for UHV applications Prepared by J.M. JIMENEZ AT/VAC/SL Section Graphite Outgassing Measurements for UHV Applications Main topics What did we learn from past experiences? Static

More information

ADDENDUM IMPORTANT DOCUMENT INVITATION TO BID ADDENDUM. OPENING DATE & TIME: January 3, 2018 at 3:00PM

ADDENDUM IMPORTANT DOCUMENT INVITATION TO BID ADDENDUM. OPENING DATE & TIME: January 3, 2018 at 3:00PM Procurement Services ADDENDUM IMPORTANT DOCUMENT INVITATION TO BID ADDENDUM ITB NUMBER: 1708MC OPENING DATE & TIME: January 3, 2018 at 3:00PM ITB TITLE: X-Ray Photoelectron Spectroscopy System ADDENDUM

More information

Flow in a shock tube

Flow in a shock tube Flow in a shock tube April 30, 05 Summary In the lab the shock Mach number as well as the Mach number downstream the moving shock are determined for different pressure ratios between the high and low pressure

More information

KARL SUSS MJB3 UV400 Mask Aligner Standard Operating Procedure

KARL SUSS MJB3 UV400 Mask Aligner Standard Operating Procedure KARL SUSS MJB3 UV400 Mask Aligner Standard Operating Procedure Version: 1.0 February 2014 UNIVERSITY OF TEXAS AT ARLINGTON Nanotechnology Research Center (NRC) 1 TABLE OF CONTENTS 1 Introduction 3 1.1

More information

EE 432 Lab 3 PMOS source/drain lithography and diffusion

EE 432 Lab 3 PMOS source/drain lithography and diffusion EE 432 Lab 3 PMOS source/drain lithography and diffusion Group Leader: Yue Zhang Group Numbers: Yueyi Jiao, Yin Huang, Lafit Masud TA: Andy Hoyt Section: NO. 5 Introduction: In this lab, we will perform

More information

The SPI Sputter Coater Handbook

The SPI Sputter Coater Handbook The SPI Sputter Coater Handbook Coating of Specimens SPI-Module Sputter Coater with Etch Mode 1. Mount the specimens onto the SEM stub. Keep in mind that many adhesives have high vapor pressure solvents

More information

Outgassing Measurements on EA934NA Coating. Prepared for:

Outgassing Measurements on EA934NA Coating. Prepared for: OSI Outgassing Services International 2224-H Old Middlefield Way, Mountain View, CA 94043 USA Phone +1 650 960 1390 Fax +1 650 960 1388 garrett@osilab.com -3(8/21) Outgassing Measurements on EA934NA Coating

More information

Equipment Standard Operating Procedure Greg Allion and Kimberly Appel

Equipment Standard Operating Procedure Greg Allion and Kimberly Appel Date Created: May 3, 2004 Date Modified: June 1, 2005 MA6/BA6 Mask Aligner Equipment Standard Operating Procedure Greg Allion and Kimberly Appel 1. Purpose 1.1. Photolithography involves transferring a

More information

Pressure Sensitive Paint (PSP) / Temperature Sensitive Paint (TSP) Part 1

Pressure Sensitive Paint (PSP) / Temperature Sensitive Paint (TSP) Part 1 AerE 545 class notes #12 Pressure Sensitive Paint (PSP) / Temperature Sensitive Paint (TSP) Part 1 Hui Hu Department of Aerospace Engineering, Iowa State University Ames, Iowa 50011, U.S.A Introduction

More information

Vertical in situ profiles of nitrate and oxygen in the northern Japan Sea

Vertical in situ profiles of nitrate and oxygen in the northern Japan Sea Vertical in situ profiles of nitrate and oxygen in the northern Japan Sea Dmitry D. Kaplunenko, Vyacheslav B. Lobanov, Pavel Ya. Tishchenko and Maria G. Shvetsova V.I.Il'ichev Pacific Oceanological Institute,

More information

Warnings: Notes: Revised: October 5, 2015

Warnings: Notes: Revised: October 5, 2015 Karl Suss MA6 Mask Aligner Standard Operating Procedure Faculty Supervisor: Prof. Robert White, Mechanical Engineering (x72210) Safety Office: Peter Nowak x73246 (Just dial this directly on any campus

More information

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial Supporting Information for Micro-Collection of Gases in a Capillary Tube: Preservation of Spatial and Temporal Resolution AUTHOR INFORMATION Kristin A. Herrmann Favela, 1 * Pieter Tans, 2 Thomas Jaeckle,

More information

Total Pressure Measurement Using Residual Gas Analyzers

Total Pressure Measurement Using Residual Gas Analyzers Total Pressure Measurement Using Residual Gas Analyzers M. Maskell, Old Dominion University; G. Myneni, P. Adderley, Jefferson Lab; G. Brucker, Stanford Research Systems; C. Day, Forschungszentrum, Karlsruhe

More information

SPUTTER STATION STANDARD OPERATING PROCEDURE

SPUTTER STATION STANDARD OPERATING PROCEDURE SPUTTER STATION STANDARD OPERATING PROCEDURE Purpose of this Instrument: This instrument is used for deposition of thin metal or oxide films. Source materials supplied by WVU Shared Research Facilities:

More information

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum.

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum. This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum. Specifically, today s talk will cover: Brief review of Vacuum Fundamentals Applications Using Rough Vacuum Rough

More information

FT28_mks.qxp 21/11/ :06 Page 1

FT28_mks.qxp 21/11/ :06 Page 1 FT28_mks.qxp 21/11/2005 14:06 Page 1 The critical components of a production-worthy ALD system CRITICAL Jon Owyang, Jeff Bailey & Subrata Chatterji, Aviza Technology, Inc., CA, USA ABSTRACT Fundamentally,

More information

Online DGA-monitoring of power transformers

Online DGA-monitoring of power transformers Online DGA-monitoring of power transformers Senior Industry Expert, Vaisala Finland Member of CIGRE A2/D1.47 and D1.52 WGs April 2018 Vaisala Webinar content 1. Dissolved gases why and which gases 2. Fault

More information

Chapter 5. Nov 6 1:02 PM

Chapter 5. Nov 6 1:02 PM Chapter 5 Nov 6 1:02 PM Expand to fill their containers Fluid motion (they flow) Have low densities (1/1000 the density of equivalent liquids or solids) Compressible Can Effuse and Diffuse Effuse: The

More information

Login to ilab Kiosk. Revised 05/22/2018. Load your sample:

Login to ilab Kiosk. Revised 05/22/2018. Load your sample: Login to ilab Kiosk Load your sample: 1. Check: The analysis chamber pressure is

More information

Test Plans & Test Results

Test Plans & Test Results P09051 Oxygen Gas Sensor Test Plans & Test Results By: Samuel H Shin (EE), Jeremy Goodman (ue) Table of contents 1. TITLE: OXYGEN MEASUREMENT TEST VIA FABRICATED OXYGEN GAS SENSOR SYSTEM... 2 1.1. Introduction...

More information

COBILT CA-800 Mask Aligner Equipment Operation

COBILT CA-800 Mask Aligner Equipment Operation COBILT CA-800 Mask Aligner Equipment Operation For the Micro-Electronics Laboratory At University of Notre Dame Department of Electrical Engineering This user manual is not be removed from room 247A. This

More information

OAI Model 200 Tabletop Mask Aligner Portland State University

OAI Model 200 Tabletop Mask Aligner Portland State University OAI Model 200 Tabletop Mask Aligner Portland State University WARNING: This machine exposes users to ultraviolet radiation. Do not touch the lens underneath the lamp hood as it may damage the machine and

More information

1)! DO NOT PROCEED BEYOND THIS MARK

1)! DO NOT PROCEED BEYOND THIS MARK Operating Instructions for X-ray Photoelectron Spectrometer: Physical Electronics Model 555 XPS/AES (John H. Thomas, III, Ph.D., Electron Spectroscopy) Sample Insertion: figure 1. Sample insertion rod

More information

WP2 Fire test for toxicity of fire effluents

WP2 Fire test for toxicity of fire effluents Pagina 3 di 89 TRA SFEU VTT 22.6.2009 v.2 WP2 Fire test for toxicity of fire effluents Task 2.1.2 Development of small-scale test method for fire effluents Step 1: Use of modeling Plans according to DoW:

More information

OOC RGA. Ion Pump 400 l/s. 8" ports with baked viton o-ring seals. Welsh rotary roughing pump 650 l/s manual isolation valve.

OOC RGA. Ion Pump 400 l/s. 8 ports with baked viton o-ring seals. Welsh rotary roughing pump 650 l/s manual isolation valve. LASER INTERFEROMETER GRAVITATIONAL WAVE OBSERVATORY - LIGO - CALIFORNIA INSTITUTE OF TECHNOLOGY MASSACHUSETTS INSTITUTE OF TECHNOLOGY Technical Note LIGO-T000126-00- R 11/20/2000 Vacuum pressure at the

More information

Protection schemes for critical surface in vacuum environments

Protection schemes for critical surface in vacuum environments Protection schemes for critical surface in vacuum environments Jung Hyeun Kim, Christof Asbach, and Se-Jin Yook Department of Mechanical Engineering, Particle Technology Lab, 111 Church Street, University

More information

Nordiko Metal Sputtering System Standard Operating Procedure

Nordiko Metal Sputtering System Standard Operating Procedure Nordiko Metal Sputtering System Standard Operating Procedure Specifications : Target Size Gases used in the system Base pressure Sputtering pressure Substrates used Substrate size : 2 inch or 4 inch :

More information

MANUAL FOR SPTS APS (DIELECTRICS ETCHER)

MANUAL FOR SPTS APS (DIELECTRICS ETCHER) MANUAL FOR SPTS APS (DIELECTRICS ETCHER) To be read first: SPTS APS is an etcher dedicated to dielectrics (SiO 2, Si 3 N 4, glass types...). Dielectrics etching in AMS200 is no more CMi standard. AMS200

More information

Procedure of Xenon Transfer

Procedure of Xenon Transfer Procedure of Xenon Transfer Feng Zhou,MIT CC: Martina Green February 28, 2005 In this write up, we discuss the procedure on how to transfer xenon to a designed gas storage vessel that supplies xenon to

More information

ACCELERATOR VACUUM PROBLEMS: IN-LINE OIL TRAPPING BETWEgN THE STANFORD LINEAR ACCELERATOR AND THE BEAM SWITCHYARD

ACCELERATOR VACUUM PROBLEMS: IN-LINE OIL TRAPPING BETWEgN THE STANFORD LINEAR ACCELERATOR AND THE BEAM SWITCHYARD slac-pub-75 March 1965 ACCELERATOR VACUUM PROBLEMS: IN-LINE OIL TRAPPING BETWEgN THE STANFORD LINEAR ACCELERATOR AND THE BEAM SWITCHYARD E. L. Hoyt and E. L. Garwin Stanford Linear Accelerator Center Stanford

More information

Savannah S100 ALD at SCIF, UC Merced Standard operating Procedure

Savannah S100 ALD at SCIF, UC Merced Standard operating Procedure This document covers the procedure that should be followed for normal operation of the Cambridge NanoTech: Savannah S100 (Atomic Layer Deposition ALD). This tool is design to be used with whole 4inch wafers.

More information

Chuck Cleaning Wafer (CCW) to remove dusts / particles on wafer chuck (Electrostatic, Vacuum, Mechanical) to be cause of machine troubles

Chuck Cleaning Wafer (CCW) to remove dusts / particles on wafer chuck (Electrostatic, Vacuum, Mechanical) to be cause of machine troubles Chuck Cleaning Wafer (CCW) to remove dusts / particles on wafer chuck (Electrostatic, Vacuum, Mechanical) to be cause of machine troubles Contact KYODO INTERNATIONAL INC. http://www.kyodo-inc.co.jp/ 2-10-9

More information

Issue: H Title: CHA E-Beam Evaporator Page 1 of 7. Table of Contents

Issue: H Title: CHA E-Beam Evaporator Page 1 of 7. Table of Contents Title: CHA E-Beam Evaporator Page 1 of 7 Table of Contents Purpose/Scope... 2 2.0 Reference Documents... 2 3.0 Equipment/Supplies/Material... 2 4.0 Safety... 2 5.0 Set Up Procedures... 2 5.1 PC Logon and

More information

The Helium Leak Detector

The Helium Leak Detector The Helium Leak Detector Helium Leak Detector Main Components The main components of a helium leak detector are: 1. The analyzed, which enables to separate the tracer gas from other gases inside leak detector.

More information

at NIST: ultra-low outgassing rates

at NIST: ultra-low outgassing rates Traceable outgassing measurements at NIST: ultra-low outgassing rates and new materials James Fedchak Thermodynamic Metrology Group Sensor Science Division Physical Measurement Laboratory Vacuum Project:

More information

A novel class of Non Evaporable Getter (NEG) alloys with lower hydrogen equilibrium pressure and reduced outgassing properties

A novel class of Non Evaporable Getter (NEG) alloys with lower hydrogen equilibrium pressure and reduced outgassing properties A novel class of Non Evaporable Getter (NEG) alloys with lower hydrogen equilibrium pressure and reduced outgassing properties P. Manini, FabrizioSiviero, A. Gallitognotta, L. Caruso, T. Porcelli,G. Bongiorno,

More information

Angstrom Dielectric Sputterer Operation Manual

Angstrom Dielectric Sputterer Operation Manual Angstrom Dielectric Sputterer Operation Manual I. System overview The Angstrom Dielectric Sputterer (ADS) has a similar interface as the Angstrom metal sputterer. It has two screens, the process screen

More information