1 Combination Welding and Cutting Torches Victory Standard Combination Torches, operate on medium or low pressured acetylene gas, are designed for economy safety and convenience. The below numerical values are all approximations. Model Set with Tip No. Range (mm) Oxy. (kg/cm²) Ace. (kg/cm²) cutting tips 7 welding tips & spanner 3 cutting tips 7 welding tips & spanner 1,, & 3 00,, 0, 3, 400, 4 & 0 1,, & 3 0, 3, 400, 0, 6, 800 & Strong Heavy Duty Hand Cutting Torch Strong Heavy Duty Hand Cutting Torch ( ) covering a range of metal thickness up to 0mm ( ). The below numerical values are all approximations. Size No. Orifice (Ø mm) Thickness to be cut (mm) Gas (kg/cm²) Oxygen Fuel Gas Strong8 Medium Duty Hand Cutting Torch Strong8 Medium duty hand cutting torch ( 80000) covering a range of metal thickness up to 80mm (3 ). The below numerical values are all approximations. Size No. Orifice (Ø mm) Thickness to be cut (mm) Gas (kg/cm²) Oxygen Fuel Gas ~7 5~ ~0 ~ ~ 40~

2 Save Point Flash Arrestor Save Point is an indispensable equipment for gas welding & cutting operation as a highlevel safety device which has 4 (four) functions of preventing a reverse flow, Preventing Backfire or Flashback completely, OneTouch Restoration after flashback, and gas supply. Extinguishing filter Outlet Eccentriccam (Onetouch Resetter) Inlet Check valve Lock Spec. Applicable Gas Max. Working capacity Connecting Dia. Length Inlet connection Outlet connection Station Flashback Arrestors Model DSS5 Gas : 5,000 l/hour Gas Inlet : 0. to 1.0 kg/cm² Type SA SQ Acetylene, Propane etc. (except, Hydrogen) 1.3 kgf/cm² Nm³/h (under P 0.5kgf/cm²) M 16 x 1.5L Female M 16 x 1.5L Male 05g 80 8A 76mm Oxygen kgf/cm² Nm³/h (under P 8kgf/cm²) M 16 x 1.5L Female M 16 x 1.5L Male g 8 Use Supply clean water from the Water Inlet to the level line of Water Level Window. If water exceeds in, open the Drain Valve and adjust it to the level line. Function Gas flows from the Inlet to the Outlet through the water in the Water/ Gas Separating Chamber. When back fire occurs, exploded gas breaks the Rupture Disc Plate and blows from the Upper Water Chamber. At the same time, the Counterflow Preventer will be closed and cut flow of gas. Caution of gas in use is 0. to 1.0 kg/cm² at the Inlet. Keep water in the Water/Gas Separating Chamber and Upper Water Chamber, and inspect water level once a day before using of gas. When back fire occurs, close the Gas Inlet Valve as early as possible. * The below numerical values are all approximations. Type DSS5 5m³/h Outlet PF3/8 Female 8kg Inlet PT3/8 Female Height 0mm 805 Model DSS7 Gas : 7,000 l/hour Gas Inlet : 0. to 1.0 kg/cm² Use Same as above. Function When back fire occurs, exploded gas breaks Rupture Disc Plate and at the same time, the Flashback Cutoff Valve will be closed automatically. In case of counter flow of gas, the Counterflow Preventer will be closed by pressure of gas. Caution of gas in use is 0. to 1.0 kg/cm² at the Inlet. Keep water in the Water/Gas Separating Chamber and Upper Water Chamber, and inspect water level once a day before using of gas. * The below numerical values are all approximations. Type DSS7 7m³/h Outlet PF1/ Female 11kg Inlet PT1/ Female Height 600mm

3 Model DSS Gas capacity : 0,000 l/hour Gas Inlet : 0. to 1.0 kg/cm² Use Supply clean water from the Water Inlet to the level line of Water Level Window and then, close the Ventilation Valve and the Water Supply Valve and supply again full of water to the Sub Water Chamber. When the water inside of chamber less than the level line, open the both valves to increase water. Function & Caution: Same as DSS7 * The below numerical values are all approximations. Type Inlet 0m³/h 1B5KF Outlet Height DSS 1B5KF 8mm Model DSS 40, 60 & Gas capacity : 40, 60 and m³/hour, respectively Gas Inlet : 0. to 1.0 kg/cm² Use, Function & Caution Same as DSS. * The below numerical values are all approximations. kg 8 Type DSS40 DSS60 DSS 40m³/h 60m³/h m³/h Inlet Outlet 1½B5KF B5KF ½B5KF Height 1,0mm 1,400mm 1,700mm 5kg 1kg 16kg

4 New Aster Regulator Oxygen Modern Compact single stage regulators equipped with/without steel made Gauge Protectors, which protect regulator from bumps, knocks and broken gauges. The regulators provide efficient and dependable control of gas, these flow controls deliver a sufficient flow of gas for most welding and cutting operations. Acetylene Applications Primary Working Secondary Working Gauge Inlet Outlet : Without protector With protector Oxygen 0kg/cm² (max) kg/cm² 35Nm³/hr. (at 5kg/cm²) 0 0kg/cm² 0 kg/cm² 1180g Acetylene.5kg/cm² (max) kg/cm² Nm³/hr. (at 0.5kg/cm²) 0 kg/cm² 0 kg/cm² 80g Argon Regulators AH 1CD When the Argon pressure in the cylinder reduces to or so, a lamp and buzzer of the alarm can give a warning to you. This regulator is compensated (wellbalanced as atmosphere) to provide constant delivery and flow regardless of decaying inlet pressure. Metal gaskets are put at connecting positions of the pressure gauges and flow meter, furthermore Gas leakage from every connecting positions are protected by using metal touches. Gas Application Primary Primary Alarm meter Argon max. kg 16 kg/cm² about kgf/cm² NL/min. 805 Co Regulators EH NCD Primary Gauge Secondary Gauge Inlet Connection Hose nipple Battery 00 kgf/cm² 0 kgf/cm² JIS/BS/CGA Ø 6mm 6V When the CO pressure in the cylinder reduces to kgf/cm² or so, a lamp and buzzer of the alarm can give warning to you. Being builtin the regulator, a cartridgeheater has an excellent heatefficiency and durability comparing with other equivalents. You can easily note the variation of temperature by discolouration of the thermosticker. Gas Application CO Hose Nipple Ø6mm Primary Cylinder Electric ACV/00/0V Primary 13 kg/cm² Heater 190W Alarm about kgf/cm² Set Temperature 60ºC meter NL/min. Length of Electric Cord M Primary Gauge 00 kgf/cm² ThermoSticker ºC Secondary Gauge 06 kgf/cm² 3.KG Inlet Connection JIS/BS/CGA Battery capacity 6V

5 AH series regulators are compensated (balance) to provide constant delivery pressure and flow regardless of decaying inlet pressure. This us the same performance characteristic found in more costly twostage regulator. AHN AHN 805 AHN Applicable gases Primary P.(kgf/cm²) P.(kgf/cm²) Max. Rate (N l/min) meter (N l/min) AHN1 1 ~ 6 ~ 8051 * AH pressure is fixed. AHN Ar N O He etc. 1.5 ~ 805 AHN3 1 ~ BH series twostage regulators provide a constant nofluctuating gas flow from start to finish of your operations. Once the working pressure is set, no further attention to the regulator is necessary. These precision devices save time and gas. BHN1 BHN BHN Applicable gases Primary P.(kgf/cm²) P.(kgf/cm²) Max. Rate (N l/min) meter (N l/min) BHN1 1 ~ 3 ~ * BHN pressure is fixed. BHN Ar N O He etc. 1.5 ~ 8053 BHN3 1 ~ GH series single stage regulators are designed for light to medium applications. Uses include welding and cutting, insert gas welding, in laboratories and with flowmeter. GHN1 805 GHN 8051 for Argon 813 for CO GHN Applicable gases Primary P.(kgf/cm²) P.(kgf/cm²) Max. Rate (N l/min) meter (N l/min) GHN1 1 ~ 6 ~ 805 * GHN Secondary pressure is fixed. GHN Ar N O He etc. 1.5 ~ 8051 GHN3 1 ~ CH series pipeline regulators are designed for outlet stations, suitable for optimum control and delivery pressure far from central gas manifolds. CHN1 CHN CHN * Stainlesssteel made Diaphragm is used for Helium & Hydrogen Gases. * Please make sure your using gas name in your ordering. Applicable gases Primary P.(kgf/cm²) P.(kgf/cm²) Max. Rate (N l/min) meter (N l/min) CHN1 CHN CHN3 Ar N O CO C H He etc. 1 ~ 3 ~ * CHN4 Available for panel setting. ~

6 Electrically Heated Regulators EH1N EHN Function: High flows of CO lead to the formation of dry ice crystals inside regulator orifices. These crystals reduce or stop flows completely. EH series electrically heated, thermostatically controlled, regulator prevent internal dry ice accumulations and freezeup. Features: (1) Small but a high thermal efficiency. () Attached thermal seal shows the temperature (ºC) of heater. (3) Builtin over heat protector (EH and EH) EH3N EH4N Applicable Gases Primary (kgf/cm²) (kgf/cm²) Rate (N l/min) Primary Gauge (kgf/cm²) Gauge (kgf/cm²) meter (N l/min) (kg) EH1N EHN EH3N EH4N CO (Nonsyphon cylinder) Max. 1 ~ 3 Max. No Gauge 0 ~ 0 No Gauge 0 ~ 0 1 ~ 6 ~ No meter Input : AC1/0V, Heater capacity : 190W, Cord length : m EH1 EH3 EH4 EH1 Applicable Gases CO (Nonsyphon cylinder) Primary (kgf/cm²) Max. (kgf/cm²) Rate (N l/min) 3 (Fixed) 1 ~ 3 Max.70 3 (Fixed) Primary Gauge (kgf/cm²) 0 ~ 0 No Gauge 0 ~ 0 0 ~ 0 EH1 Gauge (kgf/cm²) meter (N l/min) No Gauge 5 ~ 0 ~ 6 0 ~ 6 No meter No Gauge ~ (kg) EH3 Applicable Gases Primary (kgf/cm²) (kgf/cm²) Rate (N l/min) EH3 EH4 CO (Nonsyphon cylinder) Max. 1~ 3 1~ 3 Max.10 Input : AC1/0V, Heater capacity : EH 380W EH 570W Cord length : m Available for 5kg/cm² delivery pressure. Primary Gauge (kgf/cm²) No Gauge 0 ~ 0 Gauge (kgf/cm²) 0 ~ 6 0 ~ 6 meter (N l/min) No meter (kg).8.85 EH

7 High Working Cylinder Regulators The below numerical values are all approximations KRH KR80H KR10H KR170H TKRK TKRK High Regulators for distribution lines TKR TKR TKR TKR Large Regulators for central manifold or distribution lines GS GS GS140L GS00L 5. Large Regulators for distribution lines GS GS

8 Outlet station Regulators For Oxygen Nitrogen, Argon, Hydrogen, Helium, Acetylene, etc. The below numerical values are all approximations. Pipeline Regulators GL GL GL GL60 GL10 GL Large Regulators for Acetylene manifolds or distribution lines GS GS Large Low Working Regulators RF RF400P MGS RSC Large Regulators for large manifold or gas type distribution lines Maximum (kg/cm²) GS0P GS000P GS00P

9 EXmk II G3 EX400mk II G EX600mk II G EX700mk II EX0mk II G1 EX0mk II G EX0mk II G1 EXM EXM0 EX0mk II EX4000mk II High Purity Gas Regulators Chiyoda Seiki s Excellent series high purity gas regulators are carefully constructed for using properly in electronic, aerospace and ultrapure gas system fields. Exmk II Series are consisted in three grades, such as G1, G and G3. Each grade product is constructed under careful consideration about the construction. Applications: Analysis Carrier Gases, Semiconductor Manufacturing Gases, Poisonous & corrosive gases. Grade G1 G G3 Helium leak rate Connections Cleaning Assembling Material Packaging Inlet Normal Rate Maximum Rate Coefficient Temperature Range Dew Point Helium Leak Rate 1x 8 Acc/sec. 1x 7 Acc/sec. 1/4VCR or Tube Screw in Twosteps ultrasonically cleaning In a Class 0 Clean room Stainless steel 316 Packed in a polyethylene film under N 0NL/min NL/min 0.05max ~60ºC 70ºC 1x 8 Acc/sec. 1.kg NL/min 0NL/min 0.05max ~60ºC 70ºC 1x 8 Acc/sec. 1.3kg 805 Compressed He 1hours Screw in EX0mk II EXmk II EX0mk II EX400mk II Inlet Normal Rate Maximum Rate Coefficient Temperature Range Dew Point Helium Leak Rate kgf/cm² 0NL/min NL/min 0.17 ~60ºC 70ºC 1x 8 Acc/sec. 0.9kg 8050 kgf/cm² NL/min 0NL/min 0.17 ~60ºC 70ºC 1x 8 Acc/sec. 1.0kg kgf/cm² 0NL/min 4NL/min 0.60 ~60ºC 70ºC 1x 7 Acc/sec. 3.5kg kgf/cm² 0NL/min NL/min 0.05max ~60ºC 70ºC 1x 8 Acc/sec. 1.9kg kgf/cm² 0NL/min 000NL/min 1.75 ~60ºC 70ºC 1x 6 Acc/sec. 6.0kg 805 6kgf/cm² NL/min 0/min 0.05max ~60ºC 70ºC 1x 8 Acc/sec..0kg EX0mk II EX600mk II EX700mk II EX0mk II EX4000mk II 8kgf/cm² 4000NL/min 00NL/min 3.58 ~60ºC 70ºC 1x 6 Acc/sec. 16kg Single Stage Stainless Steel Regulators ExM (Excellent Mega) Series single stage stainless steel regulators are designed for Instrument Analysis or Semiconductor Manufacturers where high purity must be maintained. This series regulators are more accuracy than our EXmk II series and have been founded to have a leakage rate of less than 1 x Acc/sec. of helium. Inlet Normal Rate Maximum Rate Coefficient Temperature Range Dew Point Helium Leak Rate Connections Finish EXM0 EXM EXM0 EXM600 0NL/min NL/min 0.05 ~60ºC 74ºC 1x Acc/sec. 1/4VCR or Tube NL/min 0NL/min 0.05 ~60ºC 74ºC 1x Acc/sec. 1/4VCR or Tube kgf/cm² 0NL/min NL/min 0.17 ~60ºC 74ºC 1x Acc/sec. 1/4VCR or Tube kgf/cm² NL/min 0NL/min 0.17 ~60ºC 74ºC 1x Acc/sec. 1/4VCR or Tube Electropolished Rmax. 0.7µm * EXM700, EXM0, EXM4000 regulators available for large flow. 1.35

10 STRONG AUTO Automatic Gas Cutting Tool The VIC 7 STRONG AUTO is a unique automatic gas cutting machine, designed for all purposes, easy operation, accuracy and efficiency. It s suitable for small shops. Power Source Motor Speed Control Method Cutting Thickness Cutting Speed Wheel Drive.7Kgs. 0V AC DC 1V, 700rpm. Speed reducer:1/0 Transistor Control 5~mm Friction drive SingleHand Operated Cutting Machine (Bent Handle) The VIC3 is a semiautomatic portable flame cutting machine, featuring compact and light weight construction for well balanced one hand operation. The machine is applicable for straight line, bevelling and circle cutting with standard accessories. Power Source Cutting Speed Max. Cutting Thickness Bevel Cutting Dimensions (mm) AC V or 00V ~0mm/min 5mm 45º 387(L) x 13(W) x 0(H) Body 7.1kgs, Rail 3.kgs SingleHand Operated Cutting Machine (Straight Handle) The VIC4 is used for the same applications of the above VIC3. Straight handle type, compact and light weight construction for balance singlehand operation in straight line, bevelling circle and free cutting. The simple rugged construction of VIC4 makes for maintenance free mechanism and a longtime use. Power Source Cutting Speed Max. Cutting Thickness Circle Cutting Range Dimensions (m/m) (without rail) AC V or 00V 0mm/min. 5mm 60100mm dia. 460(L) x 10(W) x 40(H) 9.8kgs Automatic Portable Flame Cutting Machine The VIC1 has installed the Pishutter (Quick Action Gas Saving Valve) with the following merits: Saves more than % of Oxygen and Fuel Gas. Once adjust flame, never at all. A single action is enough for releasing and stopping of Oxygen and Fuel Gas Valves. Dimensions (mm) Total Motor Speed Control Driving Speed Cutting Rail Dimensions (mm) 0 (L) x 135 (W) x 180 (H) 9.3kgs D.C. Motor, 7,0 r.p.m. TRIAC ~0mm/min 3~60mm 160 (W) x 1800 (L), common to VIC

11 Gas Pipe Cutting Machine The VIC65 (Chain Driven Portable Pipe Cutting Machine Manual Operation) travels manually around the pipe with 4 wheels by a chain. The machine is constructed for maintenance free mechanism, easy operation and a very light weight (9 kgs). Features: Smooth, dependable chain drive. Simplified operational control. Adjustable blowpipe angle for edgecutting. Handy and lightweight (8.5 kgs). Capacities: Pipe Dia. Cutting Thickness Edge Shape Cutting Tip ~ 600mm by standard chain of 400mm Available extra chain Up to mm I or V cutting (V Bevel up to 45º) A3800 (ACET.), P30 (G) Automatic Gas Pipe Cutting Machine The VIC66 is a portable auto pipe cutting machine, designed for labor saving and rationalization as well as to include all the best features of the VIC65 which has a fine reputation. Cutting Thickness Cutting Speed Effective Pipe Diameter Bevel Angle Motor Power Source Cutting Tip 5mm ~700/min. 0~600mm dia. Up to 45º 00 r.p.m. AC 1V: AC 0V 14 Kgs. A3800 for ACET. P30 for G Pipe Hole Cutting Machine The VIC33 has been developed especially for making round holes on curve surfaces such as ship hullspressure vessels, branch holes in pipes. Moreover, the machine is able to use for circle cutting on flat plate, when the stroke length at zero. Gross Height Width Depth Capacities Effective Cutting Diameter Effective Vertical Stroke Max. Circle Cutting Speed Minimum Diameter of Pipe To Be Cut Cutting Thickness Control Method Motor kgs 0 mm 100 mm 600 mm 800 mm 0160 mm 800mm/min mm 6mm SCR (Wardleonard) DC shunt motor, W 1/0V, 6000rpm * Bevel cutting is also available by using an optional Bel Cutting Attachment. 1.37

12 Portable Eye Tracer Our compact eye tracers model: VIC9PT is designed for repeat cutting and any different shape cutting in order to meet these demands with attractive price, high efficiency and accuracy in operation Eye Tracer Cutting Area Tracing Area Cutting Thickness Tracing Speed Kerf Compensation Cutting Torch Tracing Accuracy Cutting Torch Power Source Portable ShapeCutting Machine The VIC is an automatic portable precision flame shapecutting machine, featuring automatic magnet tracing of template. The compact unit contains a builtin variable speed driving mechanism and it is simple, yet rigid construction assures superb durability. The advance design provides ease of operation and highly accurate performance and it does not necessarily need skilled labor to operate the machine. Voltage Speeds Cutting Thickness Cutting Range Circle cutting Magnet Roller Diameter Portable Circle Cutting Machine Linecentre Tracing System, Friction Drive (DC µ Motor Drive). 600mm (width) x 600mm (length) 600mm (width) x 600mm (length) 5 60mm 7mm/min. ±1.5mm (total mm) ± 0.mm deviation from edge of line on straight line torches with minimum distance of 75mm between torches 35 kgs AC /00/0/40V /60 Hz, 1 Phase AC 00 Volts 0mm/ min 3 mm 700 mm Ø 600 1,700 Ø (Standard) (Using attachment) mm 33 kgs The VIC3 is automatic portable precision flame circle cutting machine, featuring easy automatic circle cutting. The compact, light weight unit contains a builtin variable speed driving mechanism and rigid construction with high accuracy assures perfect roundness of cutting. The advanced design provides ease of operation and highly accurate performance even without skilled labor. Dimensions Total Thickness of Cut with Standard Blowpipe Circle Cutting Range Driving Power Cutting Speed per Minute 7(L) x 6 (H) x 370 (W) mm kg 0mm (4.69 ) 600mm Ø (standard) DC V, W Shunt motor to 8mm/ min (S.C.R. control) (Variable with builtin SCR Speed control system)

13 Auto Spider0 Featuring very light weight body with quick action gas shutoff valve & magnet provide easy carrying & all position cutting. Cutting Cutting Thick Voltage 0mm Ø 4.5mm AC V or 00V 5.8kgs A = Web size B = Flange Size t = Thick of Material Portable Automatic Shape Steel FlameCutters COSMO Jr. Z portable automatic shape steel flamecutters using oxypropane or oxyacetylene, enable cutting of large shape steels at storage sites and eliminate costly installation. Since they are designed to flamecut shape steel of any kind, COSMO Jr. Z flamecutters are widely used in the construction, bridgebuilding, and steel manufacturing fields. Specifications F0 F400 F600 Power Source Motor Machine Speed (mm) AC 0V. 1Ph. /60Hz. DC Shunt Geared Motor x 0800 mm/min Machine Dimensions w/out rails Length x Width x Height (mm) Machine (kg) Vertical Rail Length (mm) Transverse Rail Length (mm) 170 x 180 x x 180 x x 190 x Cutting Ranges Web Size To Be Cut (mm) Flange Size To Be Cut (mm) Thick of material To Be Cut (mm) Using Fuel Gas F0 F400 F600 0~600 ~0 0~900 ~400 0~1700 ~600 Depend upon the No. of tip Propane or Acetylene Valves for Gas Manifold CutOff Valves Neck Valves Outlet Valves KV0C KV0A BO1 KV0F KV0T BO KV0CIS SVAU BA1 BA SVCAIS 1/ x 1/ 1.39

Chiyoda's High-Pressure Gas Control System and Equipment

Chiyoda's High-Pressure Gas Control System and Equipment Chiyoda's High-Pressure Gas Control System and Equipment 2012 CHIYODA HELPS YOUR GAS RELATED JOBS... Since the establishment 1946, we started as a manufacturer of Gas Welding & Cutting Equipment. Nowadays

More information

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES P0170E-1.DOCX/08.16/MG CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES With a Central Gas Supply System, individual work places or gas take-off stations are supplied with gas through

More information

PRESSURE CONTROL REGULATORS

PRESSURE CONTROL REGULATORS REGULATOR HARRIS STYLE SINGLE STAGE 201 Series Medium Duty Single stage construction Forged brass body for maximum strength Chrome bonnet Neoprene diaphragms Sintered metal inlet filter to trap impurities

More information

4 Machine maintenance and repair

4 Machine maintenance and repair 3.3 lift device consists of: lift motor, lead screw, guide rod, lifting seat Lift motor Lead screw Guide rod Lifting seat Diagram 3.3 3.4 torch holder set The torch holder consist of holder connection,

More information

HIND MEDICO PRODUCT (AN ISO 9001:2008 CERTIFIED COMPANY)

HIND MEDICO PRODUCT (AN ISO 9001:2008 CERTIFIED COMPANY) HIND MEDICO PRODUCT (AN ISO 9001:2008 CERTIFIED COMPANY) INDUSTRIAL GAS EQUIPMENT AND WELDING SOLUTIONS ABOUT US To Our Valued Customers, CHOICE Something we will all like to have but do not always get!

More information

BRAZING & CUTTING. Kits Easy To Use

BRAZING & CUTTING. Kits Easy To Use BRAZING & CUTTING Kits Easy To Use Easy to use kits fully or partly (equipped with quick connections) assembled kits for brazing (kits no. 1 and no. 2) or cutting (kits no. 3 and no. 4). HIGH QUALITY PRODUCED

More information

Portable Automatic Gas Cutter

Portable Automatic Gas Cutter Portable Automatic Gas Cutter BHA00B20 OPERATION MANUAL For every person who will be engaged in operation and maintenance supervision, It is recommended to read through this manual before any operations,

More information

NEW Edge Series Products: OUTFITS and REGULATORS

NEW Edge Series Products: OUTFITS and REGULATORS NEW Edge Series Products: OUTFITS and REGULATORS NOW Including ESS3 Models and More Edge Series Outfits User Friendly Advanced Design Outstanding Flow Performance Unsurpassed Safety www.victoredge.com

More information

Visit our Web site: http: //

Visit our Web site: http: // CONTENTS: Medium Duty Victor Style Welding And Cutting Outfit MANUFACTURED BY AN ISO 9001 REGISTERED FIRM Visit our Web site: http: // www.northerntool.com TABLE OF CONTENTS Page INTRODUCTION... 1 SECTION

More information

Typical Single Stage Design SR 450 Series Shown. Two stage regulators add the following in addition to the features listed above:

Typical Single Stage Design SR 450 Series Shown. Two stage regulators add the following in addition to the features listed above: Single Stage : Recommended for applications where slight delivery pressure increases (due to decreasing cylinder pressures) would not affect the performance characteristics of the work or test results.

More information

IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES

IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES GAS SAFETY ENGINEERING GAS MANIFOLD SYSTEMS AUTOGENOUS ENGINEERING FLAME SPRAYING GAS MIXERS IBEDA GAS MIXERS FOR MANY AREAS OF

More information

Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve)

Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve) Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve) When working pressure change, inside diaphragm and needle valve operates in order to always keeping a fixed flow rate for exact

More information

WELDING TOOLS AND ACCESSORIES

WELDING TOOLS AND ACCESSORIES WELDING TOOLS AND ACCESSORIES WELDING TOOLS AND ACCESSORIES Hoses / Automatic roller for oxygas hoses.............................................. 89 Quick action coupling.................................................................

More information

VIC offers a variety of Calibrated Gas Leaks

VIC offers a variety of Calibrated Gas Leaks CALIBRATED GAS LEAKS VIC offers a high quality line of calibrated gas leaks traceable to National Institute of Standards Technology (NIST). Calibrated gas leaks are used to provide a controlled delivery

More information

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw. Premium Series High Quality Forged Brass Body Rust-Resistant Nickel Plated Finish Long Life Corrosion Resistant Valve Seat Economical Price & Reliable Performance Tamper-Resistant locking Screw Reduces

More information

CI-SfB 732 (5-1) x. - laboratory fittings

CI-SfB 732 (5-1) x. - laboratory fittings CI-SfB 732 (5-1) x - laboratory fittings - ordering information Generally, item numbers for fittings have the following structure XL XX XXX 10 XX - XX X brownall Labtap Series no. Models 30 - Angle valves

More information

Description Advanced Features Typical Applications

Description Advanced Features Typical Applications Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied

More information

A guide to Part 10 of the

A guide to Part 10 of the OCCUPATIONAL HEALTH AND SAFETY DIVISION Welding, Cutting, Burning and Soldering A guide to Part 10 of the Occupational Safety General Regulations October 2007 A GUIDE TO PART 10 WELDING, CUTTING, BURNING

More information

Self-operated Pressure Regulators for special applications

Self-operated Pressure Regulators for special applications Self-operated Pressure Regulators for special applications Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Application Pressure regulators for cryogenic

More information

Specification & scope of work for Multi Component Gas Separation test Rig

Specification & scope of work for Multi Component Gas Separation test Rig XUR Specification & scope of work for ulti Component Gas Separation test Rig 1. Design, supply, assembly and commissioning of the ulti-component gas separation Test rig as per the schematic layout given

More information

PRO-50 Instrument Supply Regulator

PRO-50 Instrument Supply Regulator Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits

More information

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds

More information

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times Tseries Series AB AB Air Air Boosters Boosters The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times.01/1 MANIFOLD MOUNTED VALVES FOR EASY SERVICING

More information

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES PROCESS ANALYSERS DF-550E The DF-550E Nano Trace oxygen analyser is a Coulometric sensor based analyser designed to measure oxygen as a contaminant at ultra trace levels in ultra high purity electronic

More information

Specifications. Dimensions Product Only With Packaging Materials of Construction Kit Box. Equipment Tray Insert. Oxygen / Acetylene GWKOA

Specifications. Dimensions Product Only With Packaging Materials of Construction Kit Box. Equipment Tray Insert. Oxygen / Acetylene GWKOA WELDING, BRAZING AND CUTTING KITS Tesuco offers a range of oxygen / acetylene and oxygen / LPG kits to suit the industries they are designed for. This includes complete cutting and welding kits and kits

More information

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward GN 4-7 kw/5.5-10 hp Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward Total capability, total responsibility Right at the heart of your business, Atlas Copco delivers quality compressed air

More information

OXYGEN - ACETYLENE Cutting - Welding - Heating and Brazing Kit

OXYGEN - ACETYLENE Cutting - Welding - Heating and Brazing Kit GAS EQUIPMENT INDUSTRIAL CUTTING & WELDING SETS REGULATORS CUTTING EQUIPMENT WELDING - BRAZING - HEATING GAS CUTTING MACHINES AIR - PROPANE HEATING EQUIPMENT TORNADO REGULATORS HIGH PRESSURE REGULATORS

More information

Columbus Instruments

Columbus Instruments 0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011

More information

OXYGEN ACETYLENE WELDING & CUTTING EQUIPMENT

OXYGEN ACETYLENE WELDING & CUTTING EQUIPMENT OXYGEN ACETYLENE WELDING & CUTTING EQUIPMENT Introduction: The oxy-acetylene torch can be used for various tasks. It can be used for cutting steel, welding steel, brazing and for heating metal. The oxy-acetylene

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital

More information

World Area Differences Technical Information

World Area Differences Technical Information World Area Differences Technical Information DMISC2047X02 This document is to give more information about the following: Porting & Threads Cleaning Procedures Conversion Tables PORTING & THREADS NPT (National

More information

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range

More information

Tamper proof, self reseating internal safety

Tamper proof, self reseating internal safety GAS EQUIPMENT REGULATORS GENERAL FEATURES Regulators: Harris regulators are designed and manufactured according to the most recent international standards: - ISO 2503 for cylinder pressure regulators for

More information

AUTOMATIC HOSE TEST UNIT, TYPE SPU

AUTOMATIC HOSE TEST UNIT, TYPE SPU VALVES AND FITTINGS UP TO 14,000 BAR TEST AND CONTROL EQUIPMENT H IGH PRESSURE TECHNOLOGY AUTOMATIC HOSE TEST UNIT, TYPE SPU Pressure range from 1 up to 10,000 bar User-friendly touch panel operation HIGH-PRESSURE

More information

/ /

/ / GN 4- kw/5.5-0 hp Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward GN: the dual output solution From cargo blanketing in LNG vessels to the inflation of Formula tires, nitrogen is used in

More information

NGN Series nitrogen generator

NGN Series nitrogen generator NGN Series 8-64 nitrogen generator Applications how it works RK series 5-40 F Blanketing of Chemicals and Pharmaceuticals Gas Assisted Injection Moulding (GAIM) Laser Cutting Food Heat Treament of Ferrous

More information

MEDICAL EQUIPMENT CATALOG

MEDICAL EQUIPMENT CATALOG THE MOST TRUSTED MEDICAL EQUIPMENT IN NORTH AMERICA MEDICAL EQUIPMENT CATALOG Total Components Including Bulk Oxygen Supply, Back up and Delivery Equipment Designs for High Pressure, Liquid or Bulk Applications

More information

Cutting Tip SC12-1 SC12-2 SC12-1 SC12-2 SC12-1 SC12-2 SC12-1 SC12-2 SC12-1 SC12-2. Welding Tips. Heating Tip. Part No. HTA

Cutting Tip SC12-1 SC12-2 SC12-1 SC12-2 SC12-1 SC12-2 SC12-1 SC12-2 SC12-1 SC12-2. Welding Tips. Heating Tip. Part No. HTA Smith Equipment American Classic Heavy Duty, Welding & Outfits Cuts up to 8"- Welds up to /2" These premium heavy duty outfits feature Smith s proven in-tip gas mixing technology and include torch mount

More information

How Flashback Arrestors Work

How Flashback Arrestors Work What are Flashback Arrestors Flashback Arrestors prevent reverse flow of gases with built-in check valves and extinguishes flashback fire with a stainless steel sintered element. How Flashback Arrestors

More information

Gas Welding Hoses and connections, the weak link

Gas Welding Hoses and connections, the weak link Gas Welding Hoses and connections, the weak link By Leif Andersen, Technical Product Manager Welding, WSS Regulators with flashback arrestors and the shank with its welding or cutting attachment are made

More information

Model Description

Model Description LEAKHUNTER Plus LEAKHUNTER Plus Model 8066 Description The MATHESON LEAKHUNTER Plus is a truly universal leak detector. Extensive R&D has produced a multi-functional leak detector engineered to perform

More information

Measurement of Low GAS & Liquid Flows

Measurement of Low GAS & Liquid Flows Measurement of Low GAS & Liquid Flows The Measurement Measurement with a float in a tapered borosilicate glass tube. Series 2100 with a 100 mm flow tube Series 2150 with a 150 mm flow tube Series 2300

More information

Nonrefillable Cylinders

Nonrefillable Cylinders Nonrefillable Cylinders A DIVISION OF NORCO, INC. Norlab, the Specialty Gas Division of Norco, Inc., has been producing and distributing calibration mixtures and pure specialty gases in refillable and

More information

Air Amplifiers & SYSTEMS

Air Amplifiers & SYSTEMS Air Amplifiers & SYSTEMS We Accept VISA, MasterCard and American Express Air Amplifiers Point-of-Use Air Solutions Maximator air amplifiers are designed to boost plant air pressure or increase the supply

More information

300 Held Drive Northampton Pa

300 Held Drive Northampton Pa 300 Held Drive Northampton Pa 18067 610.262.6090 June 10, 2015 Recommended testing for verifying device performance. Intervals of testing are to be set by the Healthcare Provider / Dealer. Table of Contents

More information

Precision matters. HiQ equipment for specialty gases.

Precision matters. HiQ equipment for specialty gases. Precision matters. HiQ equipment for specialty gases. Pure, precise, reliable solutions. HiQ equipment. The application of specialty gases demands well-founded expertise and professional know-how. HiQ

More information

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes DS-G-REG-13-43-0812-01-A* Model 243-RPC Pilot Operated Regulators Installation and Maintenance Instructions Rugged, Reliable with Value-added Features Genuine, pilot-operated regulators use the same relay

More information

Leak free Pipe Rupture Valve for Excavators

Leak free Pipe Rupture Valve for Excavators Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................

More information

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This

More information

COMMERCIAL ITEM DESCRIPTION TORCHES, OXYACETYLENE, HAND HELD, CUTTING AND WELDING

COMMERCIAL ITEM DESCRIPTION TORCHES, OXYACETYLENE, HAND HELD, CUTTING AND WELDING INCH-POUND 2 July 2010 SUPERSEDING A-A-55826 5 September 1996 COMMERCIAL ITEM DESCRIPTION TORCHES, OXYACETYLENE, HAND HELD, CUTTING AND WELDING The General Services Administration has authorized the use

More information

North American Orifice Metering System

North American Orifice Metering System Combustion North American Orifice Metering System 8697 and M8697 Metering Orifices accurately measure gas flows to industrial burners. They are compact, inexpensive, and can be installed in individual

More information

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A Air Consumption 70% Down New Product Precision Regulator Air Saving Type RPE Series PRECISION REGULATOR RPE SERIES Large Air Saving CC-1072A Air Consumption 70% Down. New Type Eco-friendly Precision Regulator

More information

OXY FUEL SYSTEM SET UP & SHUT DOWN PROCEDURE CHECKLIST ACETYLENE FUEL GAS

OXY FUEL SYSTEM SET UP & SHUT DOWN PROCEDURE CHECKLIST ACETYLENE FUEL GAS OXY FUEL SYSTEM SET UP & SHUT DOWN PROCEDURE CHECKLIST ACETYLENE FUEL GAS Items needed for demonstrations: Fire extinguisher PPE (Personal Protective Equipment): o Lab coats/welding jackets o Leather gloves

More information

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

Multiple Pressure Booster Systems With Variable Speed Controller Type BL Multiple Pressure Booster Systems With Variable Speed Controller Type BL General Characteristics - Single or multistage pumps - Horizontal or vertical mounting - Total head 30m ~ 250m - Material construction:

More information

Air Operated Hydraulic Pumping Systems to 50,000 psi

Air Operated Hydraulic Pumping Systems to 50,000 psi High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air

More information

Nitrogen Tyre Inflator Owner s Manual

Nitrogen Tyre Inflator Owner s Manual Nitrogen Tyre Inflator Owner s Manual Model:PN-8890 Please read this manual carefully before attempting assembly or use. 1 Suit for: Motorcycle, Car, Light Truck, Bus Manual Model Nitrogen Tyre Inflation

More information

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May 2015 98-0520 S/N 2001 N. Indianwood Ave. Tulsa, Oklahoma 74012 U.S.A. TEL: (918) 250-7200 FAX: (918) 459-0165 E-mail: chandler.sales@ametek.com

More information

Mass Flow Controllers

Mass Flow Controllers Mass Flow Meters & Controllers HFM-D-3A & 305A Mass Flow Meters HFC-D-3A & 307A Mass Flow Controllers FEATURES Range 0-25 slm to 0-2500 slm (N 2 Equivalent) Excellent Accuracy ±(0.5% of Reading + 0.2%

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Installation Instructions Issue Date August 19, 2008 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied

More information

10.1 Main Unit. INDEPENDENT WHOLESALE WELDING SUPPLY Ph: Fax: Website:

10.1 Main Unit. INDEPENDENT WHOLESALE WELDING SUPPLY Ph: Fax: Website: 10.1 Main Unit 10.1 Main Unit 1 Case 60031802 1 2 Cross feed holder 60031803 1 3 Cross feed liner 60031804 1 4 Handle 60031805 1 5 Fan cover 60031806 1 6 Bottom plate 60031807 1 7 Heat shield 60031808

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm ort connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital

More information

GAS PRESSURE CONTROL UNIT TYPE 132

GAS PRESSURE CONTROL UNIT TYPE 132 GAS PRESSURE CONTROL UNIT TYPE 132 OUR DIVERSITY IS YOUR PROFIT. Gas Pressure Regulator Type 132 Scope of Application Scope of type 132 gas pressure regulator is to maintain the output pressure at a constant

More information

Instruction and Maintenance Manual

Instruction and Maintenance Manual Instruction and Maintenance Manual GRYF OXY ZM 02/100/2 E Contact GRYF HB, spol. s r.o. Cechova 314 Havlickuv Brod 580 01 tel.: +420 569 426 627 fax: +420 569 426 627 www.gryf.eu ver.: 11.2.2015 OEM module

More information

Cutting and shaping materials using thermal cutting equipment

Cutting and shaping materials using thermal cutting equipment Unit 824 Cutting and shaping materials using thermal cutting equipment UAN: H/600/5883 Level: Level 2 Credit value: 14 GLH: 64 Relationship to NOS: This unit has been derived from national occupational

More information

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL ATD-8402 90LB PRESSURE BLASTER INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS SAFETY INSTRUCTIONS FOR SANDBLASTER 1. Before opening the tank release the air pressure on the sand tank. To do this, turn off

More information

OWNER S TECHNICAL MANUAL

OWNER S TECHNICAL MANUAL EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids,

More information

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Installation Instructions Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied

More information

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane Gas requirements Gases for packed columns The carrier gas you use depends upon the type of detector and the performance requirements. Table 520-1 lists gas recommendations for packed column use. In general,

More information

Product Catalogue 2018

Product Catalogue 2018 Product Catalogue 2018 Oxy-fuel Cutting and Welding Technology Mechanische Werkstätten Wurzen GmbH Oxy-fuel Cutting and Welding Technology Mould and Tool Production Oxy-fuel Cutting and Welding Technology

More information

High Purity & Ultra High Purity

High Purity & Ultra High Purity Solar and Semiconductor High Purity & Ultra High Purity Pressure and Weight Measurement R Electronic Pressure Measurement High Purity & Ultra High Purity - Pressure and Weight Measurement WIKA offers a

More information

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD Operating Manual ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD 50 und ALU-CD 60 KGW - ISOTHERM Gablonzer Straße 6 76185 Karlsruhe Germany Tel: 0049 / 721 95897-0 Fax: 0049 / 721 95897-77 Internet: www.kgw-isotherm.com

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express AIR DRIVEN Gas Boosters & SYSTEMS Accepting VISA, MasterCard and American Express Gas Boosters AIR DRIVEN FROM 30 PSI TO 21,750 PSI MAXIMATOR Maximator gas boosters are an excellent alternative to high

More information

G96 Series BASOTROL Dual Operator Valve

G96 Series BASOTROL Dual Operator Valve Installation Instructions 9. Issue Date February 22, 2013 G96 Series BASOTROL Dual Operator Valve Applications The G96 valves are combination, dual operator, automatic valves available with or without

More information

Gas Pressure Regulator HON 200

Gas Pressure Regulator HON 200 Product information serving the gas industry worldwide Applications, characteristics, technical data Application Gas supply to municipal, industrial and individual consumers Regulator for low-load rails

More information

RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations

RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations Proven Technology. Superior Performance. Today s natural gas industry has a growing demand for operational excellence. Pilot-operated

More information

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet: OXY Integral INTERCON ENTERPRISES INC Tel: 800 665 6655 Fax: 604 946 5340 E-Mail: sales@intercononline.com Internet: www.intercononline.com Manual Integral 2006 1 INDEX 2-3 PREFACE 4 INTRODUCTION 5 Principle

More information

KMT Waterjet Systems Inc.

KMT Waterjet Systems Inc. Advancing Waterjet Technology Worldwide Sales and Support Network Making Waterjet Systems Easier to Use, with Greater Reliability ISO 9001:2000 Certification; CSA and CE Certified Trained, Certified Technicians

More information

Plasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G.

Plasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G. Yamato Scientific America Innovating Science for Over 125 Years Plasma Cleaner Contents Gas Plasma Dry Cleaner PDC200/210/510 PDC610G Gas Plasma Reactor 145 146 147 149 144 Gas Plasma Dry Cleaner Plasma

More information

MAINTANCE MANUAL CNC ROTARY TABLE MODEL: DMNC-5C YUASA INTERNATIONAL.

MAINTANCE MANUAL CNC ROTARY TABLE MODEL: DMNC-5C YUASA INTERNATIONAL. MAINTANCE MANUAL CNC ROTARY TABLE MODEL: DMNC-5C YUASA INTERNATIONAL. INDEX DESCRIPTION PAGE (1)SPECIFICATION 2 (2)OUTSIDE DIMENSION LAYOUT 3 (3)INSPECTION REPORT 4 (4)PREPARATION FOR OPERATION 5 4-1.LUBRICATING

More information

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT Compact Manometer Series PPA Pressure measurements can easily be taken any time, anywhere. G GS PPA Compact and lightweight Portable type with a lightweight of only about 100 g (unit 50 g, battery 50 g)

More information

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES PROCESS ANALYSERS DF-310E The DF-310E is a Coulometric sensor based oxygen analyzer designed to measure trace and percent level oxygen in pure and multi-gas backgrounds for process and quality control

More information

VERTICAL BLADDER TANK

VERTICAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION DUAL FUEL EXCESS AIR BURNER MODEL: 3610, 3651 Revision: 0 FEATURES Burns all fuel gases or light oils Nozzle mix design for on ratio control or excess air 350% excess air all sizes on gas or oil Turndown

More information

Basic & Controlled Atmosphere Glove Boxes

Basic & Controlled Atmosphere Glove Boxes I N T R O D U C T I O N Precise Basic and Controlled Atmosphere Glove Boxes provide a leak-tight environment for work with contamination-sensitive materials. Precise Basic Glove Boxes are simple, economical

More information

oxyacetylene welding/cutting torch set

oxyacetylene welding/cutting torch set instructions for oxyacetylene welding/cutting torch set model no: SGA2.V2 & SGA6.V2 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these

More information

The affordable consumption counter for compressed air and gases R 3 /4 (DN 20)

The affordable consumption counter for compressed air and gases R 3 /4 (DN 20) VA 420 new The affordable consumption counter for compressed air and gases R 1 /4 (DN 8) DN 15 R 3 /4 (DN 20) DN 25 R 1 1 /4 (DN 32) DN 40 R 2 (DN 50) With mit und and ohne without Flansch flange Intelligent

More information

Weld/Braze Tip Data. IMPORTANT: Use proper type of tip for each type torch. Airc o. N U M B E R Dril l Siz e. D E C I M A L Size

Weld/Braze Tip Data. IMPORTANT: Use proper type of tip for each type torch. Airc o. N U M B E R Dril l Siz e. D E C I M A L Size Note: This data has been compiled by Uniweld...We share this information and acknowledge that Uniweld s information is to the best of its ability for accuracy. Please use safe practices when welding, cutting

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete

More information

ACTUATORS AND INSTRUMENTS

ACTUATORS AND INSTRUMENTS ACTUATORS AND 03 ADVANCED ACTUATORS AND FOR A COMPLETE VALVE CONTROL SOLUTION Koso Kent Introl LIMITED (KKI) supplies a full range of advanced actuators and associated instrumentation to complement its

More information

Instruction and Maintenance Manual

Instruction and Maintenance Manual Instruction and Maintenance Manual GRYF OXY Z 02/100/2 E Contact GRYF HB, spol. s r.o. Cechova 314 Havlickuv Brod 580 01 tel.: +420 569 426 627 fax: +420 569 426 627 Czech Republic www.gryf.eu Technical

More information

Filter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with pressure gauge suitable for ATEX

Filter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with pressure gauge suitable for ATEX Filter regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with gauge suitable for ATEX 1 00119372 Version Parts Mounting orientation Working min./max. Medium Medium temperature

More information

GILMONT ACCUCAL FLOWMETERS

GILMONT ACCUCAL FLOWMETERS OPERATING MANUAL GILMONT ACCUCAL FLOWMETERS 28W092 Commercial Ave. Barrington, IL U.S.A. 60010-2392 (847) 381-4888 (847) 381-7053 (Fax) 800-962-7142 www.barnant.com e-mail: barnant@barnant.com A-1299-0766

More information

High-Purity. Ball Valves

High-Purity. Ball Valves High-Purity s Components MANUFACTURING ASSEMBLY TESTING HP High-Purity s CFOS Applications Cost-effective systems where cleaning for oxygen-grade services are required, such as: Clean-Dry Air (CDA), Oil-Free

More information

DN 50 REGULATOR SUTON 5000A1 REGULATOR SUTON 5000D1

DN 50 REGULATOR SUTON 5000A1 REGULATOR SUTON 5000D1 www.apq.com.es EU Product / Spain DN 50 REGULATOR SUTON 5000A1 REGULATOR SUTON 5000D1 Cod. RISUT5000A1 Cod. RISUT5000D1 DESCRIPTION The Suton 50001 Regulator is designed for use in distribution networks

More information

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E) ECS Protector PGEN-30 (PGEN-30E) Specifications For use under U.S. Patents 8,720,591, 9,144,700 and 9,186,533 Dimensions (cabinet): 24.5 (W) x 52.5 (H) x 8.5 (D) (622mm(W) x 1,334mm(H) x 216mm(D)) Dimensions

More information

Instruction Manual Updated 7/26/2011 Ver. 2.2

Instruction Manual Updated 7/26/2011 Ver. 2.2 4-Unit Model MB HTHP Filter Press #171-50-4: 115-Volt #171-51-4: 230-Volt Instruction Manual Updated 7/26/2011 Ver. 2.2 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele:

More information