PRODUCT CATALOG PERIPHERAL INTERVENTIONS
|
|
- Charles Houston
- 6 years ago
- Views:
Transcription
1 2018 PRODUCT CATALOG PERIPHERAL INTERVENTIONS
2 2018 Peripheral Interventions Product Catalog Alphabetical Index Page ANGIOGRAPHY Angiographic Catheter Selector Guide 3 Imager II Flush Catheters Imager II - 4 F Flush Catheters 5 Imager II - 5 F Flush Catheters 5 Imager II Select Catheters Imager II - 4 F Select Catheters 6 Imager II - 5 F Select Catheters 7 Page 2 of 8
3 2018 Peripheral Interventions Product Catalog Alphabetical Index Cerebral Curves Headhunter Commonly used for carotid, innominate and subclavian access JB Lightly curved tips for access to carotid arteries H1 H3 H1H JB1 JB2 JB3 Simmons Facilitates access of common carotid, subclavian, renal and contralateral common iliac Other Cerebral Curves ST SIM1 Newton SIM2 SIM3 Dramatic double S curve designed for larger aortic arches SIM4 BARN Commonly used for guide wire redirect BERN Facilitates access of the great vessels HN1 HN2 HN3 GEN Designed with a gentle curve HN4 HN5 WEIN Gentle curve for guide wire redirect Page 3 of 8
4 2018 Peripheral Interventions Product Catalog Alphabetical Index Visceral Curves Cobra Commonly used to access abdominal aortic vessels and internal iliacs Renal C1 Best suited for steeply angled renal arteries Chuang Flush Curves C2 RC1 RC2 RDC Longer tips facilitate distal access to the celiac and mesenteric systems CHGB CHGC CHG2.5 Tennis Racquet Designed for delivery of a compact bolus of contrast Contralateral Facilitates contralateral access Other Cerebral Curves MIK Assists with access to perpendicular ostia TRAIN Facilitates in antegrade access of branch vessels HK1.0 An open J configuration for access to abdominal aortic branch vessels CONTRA2 Commonly used for contralateral access SHK 0.8 Flared tip facilitates contratateral access SHK 1.0 Commonly used for contralateral access Pigtail Commonly used for abdominal aortagrams Straight With side holes for delivering a bolus of contrast Page 4 of 8
5 ANGIOGRAPHY Imager II - 4 F Flush Catheters Contralateral High-Flow Catheters Imager II Flush Catheters M Contralateral N/A M Contralateral N/A M Contralateral N/A Pigtail/Straight High-Flow Catheters M Pigtail N/A M Straight N/A M Pigtail N/A M Straight N/A Tennis Racquet Catheters M T.Racquet N/A M T.Racquet N/A M T.Racquet N/A Imager II - 5 F Flush Catheters Contralateral High-Flow Catheters M Contralateral N/A M Contralateral N/A M Contralateral N/A M Contralateral N/A M Contralateral N/A M Contralateral N/A Pigtail/Straight High-Flow Catheters M Pigtail N/A M Straight N/A M Pigtail N/A M Straight N/A M Pigtail N/A M Straight N/A M Pigtail N/A M Straight N/A M Pigtail N/A Page 5 of 8
6 ANGIOGRAPHY Imager II - 5 F Flush Catheters (cont.) Pigtail/Straight High-Flow Catheters Imager II Flush Catheters M Straight N/A M Pigtail N/A M Straight N/A Tennis Racquet Catheters M T.Racquet N/A M T.Racquet N/A M T.Racquet N/A M T.Racquet N/A M T.Racquet N/A M T.Racquet N/A Imager II - 4 F Select Catheters Imager II Select Catheters M ST N/A M ST N/A M BARNH N/A M BERN N/A M BERN N/A M BERN N/A M WEIN N/A M H N/A M H N/A M H1H N/A M JB N/A M JB N/A M SIM N/A M SIM N/A M SIM N/A M SIM N/A M CONTRA N/A M C N/A M C N/A M C N/A M C N/A M TRAIN N/A M MIK N/A M HK N/A M SHK N/A M SHK N/A Page 6 of 8
7 ANGIOGRAPHY Imager II - 4 F Select Catheters (cont.) Imager II Select Catheters M RC N/A M RC N/A M RDC N/A Imager II - 5 F Select Catheters Braided Torque Cerebral Selective Catheters Distal segment has 2 side holes M ST N/A M ST N/A M ST N/A M ST N/A M BARNH N/A M BERN N/A M BERN N/A M BERN N/A M BERN N/A M BERN N/A M BERN N/A M WEIN N/A M WEIN N/A M H N/A M H N/A M H N/A M H N/A M H N/A M H1H N/A M H1H N/A M JB N/A M JB N/A M JB N/A M JB N/A M JB N/A M JB N/A M JB N/A M SIM N/A M SIM N/A M SIM N/A M SIM N/A M SIM N/A M SIM N/A M SIM N/A M SIM N/A M HN N/A M HN N/A M HN N/A M HN N/A M HN N/A Page 7 of 8
8 ANGIOGRAPHY Imager II - 5 F Select Catheters (cont.) Braided Torque Cerebral Selective Catheters Imager II Select Catheters M HN N/A M HN N/A M HN N/A M HN N/A M HN N/A M GEN N/A Braided Torque Visceral Selective Catheters M CHGB N/A M CHGB N/A M CHGC N/A M CHGC N/A M CHG N/A M CHG N/A M CONTRA N/A M CONTRA N/A M C N/A M C N/A M C N/A M C N/A M C N/A M C N/A M C N/A M C N/A M C N/A M C N/A M TRAIN N/A M MIK N/A M MIK N/A M HK N/A M HK N/A M SHK N/A M SHK N/A M SHK N/A M SHK N/A M RC N/A M RC N/A M RC N/A M RC N/A M RDC N/A M RDC N/A M RDC N/A M RDC N/A Distal segment has 2 side holes Page 8 of 8
CT Transcatheter Aortic Valve Replacement (TAVR) Planning VPMC-13165C
CT Transcatheter Aortic Valve Replacement (TAVR) Planning VPMC-13165C TAVR: Overview of the Application Overview: CT Transcatheter Aortic Valve Replacement (TAVR) planning assists with the assessment of
More informationPERFORMANCE ZONES
A H E A D O F T H E C U R V E PERFORMANCE ZONES Each aspect of the graft is designed to optimize conformability and seal, with optimal radial force precisely where you need it. A PRIMARY SEAL AND FIXATION
More informationUsing the Pressure Products SafeSheath Worley Telescopic Lateral Vein Introducers to Optimize LV Lead Placement
Using the Pressure Products Lateral Introducers to Optimize LV Lead Placement vein is acutely angulated The STD is a long standard 9F sheath (11F OD/9F ID) shaped to rest in the coronary sinus without
More informationCS CANNULATION. Step-by-Step Guide. This guide contains recommendations as provided by Dr. Seth Worley, MD POWERED BY
This guide contains recommendations as provided by Dr. Seth Worley, MD POWERED BY 1 Advance dilator and CSG over 0.035 wire until dilator tip reaches the SVC. 2 Holding dilator stationary, advance CSG
More informationThe Crosser CTO Recanalization Device (Bard
Clinical dept headline Use of dept headline Crosser dept headline the CTO Recanalization Catheter dept deck DEPT YLINE n interventionist s perspective on the mechanism of action of the Crosser Catheter
More informationPitfalls & Practical Tips
Pitfalls & Practical Tips Pitfalls & Practical Tips Transducer Height and AO Pressure Equalization Guidewire Introducer Needles Guide Catheter (wedging, damping & side holes) PressureWire Drift Artifacts
More informationINTERVENTIONAL CARDIOLOGY
Y-Connector Newtech Y connector it is easy, fast and accurate single handed intra vascular device insertion. Perfect insertion device respecting the integrity of the coated surface with Combination of
More informationPRODUCT CATALOGUE OF
PRODUCT CATALOGUE OF INTERVENTIONAL CARDIOLOGY AND GENERAL MEDICAL DISPOSABLES Table of Contents INFLATION DEVICE... 4 GUIDE WIRE (PTFE)... 5 MANIFOLD... 6 PTCA Y Connector... 7 INTRODUCER SHEATH (Femoral/
More informationInspired by the challenge to create a better solution for the thoracic aorta, RelayPlus was specifically designed to:
A H E A D O F T H E C U R V E C R A F T E D F O R P R E C I S I O N Inspired by the challenge to create a better solution for the thoracic aorta, RelayPlus was specifically designed to: Respect the thoracic
More informationCrosser CTO Recanalization Catheter High Frequency Mechanical Recanalization System
Crosser CTO Recanalization Catheter High Frequency Mechanical Recanalization System Instructions for Use Crosser Catheters 14P, 14S, 18, and S6 Warning! Carefully read all instructions prior to use. Observe
More informationAccreditation Council for Graduate Medical Education
Accreditation Council for Graduate Medical Education Vascular Surgery Case Logs National Data Report Prepared by: Department of Applications and Data Analysis I. National ident Statistics Report A. The
More informationAccreditation Council for Graduate Medical Education
Accreditation Council for Graduate Medical Education Vascular Surgery Case Logs National Data Report Prepared by: Department of Applications and Data Analysis I. National ident Statistics Report A. The
More informationAccreditation Council for Graduate Medical Education
Accreditation Council for Graduate Medical Education Vascular Surgery Case Logs National Data Report Prepared by: Department of Applications and Data Analysis I. National ident Statistics Report A. The
More information(12) Patent Application Publication (10) Pub. No.: US 2017/ A1. (51) Int. Cl. (52) U.S. Cl. catheter. exxxxx XX X-12 X-2. ge:xxxxxxxxx XXXXX:
(19) United States (12) Patent Application Publication (10) Pub. No.: US 2017/0181835 A1 Kleshinski et al. US 20170181835A1 (43) Pub. Date: Jun. 29, 2017 (54) (71) (72) (21) (22) (60) MULT-ACCESS INTRAPROCEDURAL
More informationBALLOON. 1. PTA Balloon Catheter 1.1 ALLUNGA Description Technical Data Materials used Compliance Chart
BALLOON 1. PTA Balloon Catheter 1.1 ALLUNGA 1.1.1. Description 1.1.2. Technical Data 1.1.3. Materials used 1.1.4. Compliance Chart 1.1.5. Graph 1.1.6. Side by Side Comparison amg International GmbH Löhnfeld
More informationCAT & SHEEP HEART DISSECTIONS
CAT & SHEEP HEART DISSECTIONS S I P R E S E N T A T I O N F O R A N A T O M Y I I The Academic Support Center @ Daytona State College (Science 58 Page 1 of 27) 1) Determine left from right by looking at
More informationCVC Insertion Simulator
M93UB CVC Insertion Simulator Don t mark on the model and other components with pen or leave printed materials contacted on their surface. Ink marks on the models will be irremovable. Instruction Manual
More informationASAHI Neurovascular Guide Wire
ASAHI Neurovascular Guide Wire AMK-DT244 Ver.1.00 / 11TS073 Legal manufacturer Consult instructions for use Do not use if package is damaged RX ONLY Caution: Federal (USA) Law restricts this device to
More informationAir Embolism During TEVAR: Carbon Dioxide Flushing Decreases the Amount of Gas Released From Thoracic Stent-Grafts During Deployment
675621JETXXX10.1177/1526602816675621Journal of Endovascular TherapyRohlffs et al research-article2016 Experimental Investigation Air Embolism During TEVAR: Carbon Dioxide Flushing Decreases the Amount
More informationEmboli Protection Device
General Information... 99 ANGIOGUARD RX components... 100 Ordering information... 101 Emboli Protection Device Emboli Protection Device Emboli Protection Device ANGIOGUARD RX ANGIOGUARD RX with its Rapid
More informationThe Art of. Flow Restoration. Raiden3. Non-Compliant PTCA Balloon
The Art of Flow Restoration Raiden3 Japan s Recognized PCI Technology Raiden3 For Both Everyday and Complex Cases Manufactured by Kaneka Corporation, one of Japan s leading providers of interventional
More informationtad PRODUCTCATALOG DUAL-TOP TEMPORARY ANCHORAGE DEVICES (TADS) Dual-Top TAD System Kit Dual-Top Temporary Anchor Devices (TADs) Button Top TAD
DUAL-TOP TEMPORARY ANCHORAGE DEVICES (S) Dual-Top System Kit The Dual-Top system includes a well-organized storage block, which allows for repeated sterilization The Dual-Top system includes 14 of the
More informationBA SK ET A SSIST ED STONE EXTRACTION
BA SK ET A SSIST ED STONE EXTRACTION OVERVIEW, PROCEDURAL TECHNIQUE AND CASE REPORT Presented by: Adam Elfant, MD Associate Head of Gastroenterology and Liver Disease Director of Therapeutic Endoscopy
More informationStandard. Abdominal Aortic Aneurysm (AAA) Repair Trainer. Part No: 60610
User Guide Abdominal Aortic Aneurysm (AAA) Repair Trainer Part No: 6060 Standard Part No: 065-088 Issue, June 005 04 Limbs & Things For more Vascular training products visit limbsandthings.com Limbs &
More informationFluid Management Injection Team
Contrast Injector 1 Fluid Management Injection Team 10/26/2011 Team Chris Besaw Team Leader Stephen Young Communicator Rafi Sufi BSAC John Diaz de Leon BWIG Client Dr. Charles Strother UW School of Medicine
More informationAbdominal Aortic Aneurysm (AAA) Repair Trainer User Guide
Abdominal Aortic Aneurysm (AAA) Repair Trainer User Guide Designed and manufactured by Limbs & Things Limited, Sussex Street, St. Philips, Bristol, BS 0RA, UK. Telephone: +44 (0)7 3 0500 Fax: +44 (0)7
More informationSAMPLE PAGE. Section 2... Wire Rope
Section 2...................................................... Wire Rope Never use any kind of clip to directly connect two straight lengths of wire rope to form a continuous piece. Do not make up slings
More informationDrug eluting balloon catheter
E x p a n d y o u r t h e r a p y o p t i o n s Drug eluting balloon catheter Only innovations based on scientific evidence create the level of confidence required to transfer optimal treatment methods
More informationCoreValve in degenerated CoreValve 1st Re do CoreValve
TAVI summit 2012 Seoul, Sep 7, 2012 CoreValve in degenerated CoreValve 1st Re do CoreValve Eberhard Grube MD FACC, FSCAI Universitätsklinik ität ik Bonn, Medizinische i i Klinik ik und Poliklinik II, Bonn,
More informationNexus Detachable Coils
Micro Therapeutics, Inc. Irvine, California 92618 USA Phone: +1 949-837-3700 Phone: +1 949-837-2044 www.1mti.com Authorized Representative in EU: MediMark Europe BP 2332 38033 Grenoble Cedex 2 France Nexus
More informationFluid Management Injection Team
Contrast Injector 1 Fluid Management Injection Team 12/14/2011 Team Chris Besaw Team Leader Stephen Young Communicator Rafi Sufi BSAC & BWIG Client Dr. Charles Strother UW School of Medicine and Public
More informationCONSTRUCTOPEDIA NXT Kit 9797
CONSTRUCTOPEDIA NXT Kit 9797 Beta Version 2.0 August 17, 2007 Center for Engineering Educational Outreach Tufts University Table of Contents Simple Shapes and Structures. Page 3 Ways To Attach NXT Motors...
More informationProduct Specifications Specialty Junction Boxes
NOVA Energy & Automation Product Specifications Specialty Junction Boxes Model JB 03 January 2012 Product Description 1. Specialty Junction Boxes Nova Junction Boxes are custom manufactured by size, material,
More informationTUNING A DOUBLE REED DUCK CALL
TUNING A DOUBLE REED DUCK CALL By Corey Ulrich Ulrich s Custom Calls The following is how I tune my double reed duck calls and by no means is the only way to do it. This method is what I found to be the
More informationTrapLiner Catheter. Guide Extension Plus Wire Trapping
TrapLiner Catheter Guide Extension Plus Wire Trapping 2-in-1 Device Guide Extension Catheter With Trapping Capabilities The TrapLiner Catheter is a rapid exchange guide extension catheter that combines
More informationinterventional neuroradiology products catalogue
interventional neuroradiology products catalogue about balt Globally supporting healthcare professionals with integrity for over 40 years by designing cutting-edge technology and manufacturing reliable
More informationHuber needle EZ Huber JetCan. Quality and Experience
Quality and Experience Port systems TitaJet light II Contrast Jet Port Plus II Contrast DualPort Contrast TitaJet light Low Profile Contrast T-Port Contrast T-Port Low Profile Contrast TitaJet light Jet
More informationRespiration. Chapter 33
Respiration Chapter 33 Learning Objectives: Understand the basis of gas exchange and factors that influence diffusion of gases in and out of tissues Compare and contrast different respiratory systems among
More informationSprinter Family. balloon dilatation catheters. Sprinter Legend OTW Sprinter Legend RX Sprinter OTW
Sprinter Family balloon dilatation catheters Sprinter Legend OTW Sprinter Legend RX Sprinter OTW NC Sprinter RX Sprinter Family Medtronic offers you an extensive family of high-performing balloon dilatation
More informationModule Two. Objectives: Objectives cont. Objectives cont. Objectives cont.
Transition to the New National EMS Education Standards: EMT-B B to EMT Module Two Objectives: Upon completion, each participant will do the following to a degree of accuracy that meets the Ntl EMS Education
More information- How do the carotid bodies sense arterial blood gases? o The carotid bodies weigh 25mg, yet they have their own artery. This means that they have
- How do the carotid bodies sense arterial blood gases? o The carotid bodies weigh 25mg, yet they have their own artery. This means that they have the highest blood flow of all organs, which makes them
More informationWE CARE ACCURATELY. ACCURA Medizintechnik GmbH Max-Planck-Straße Karben / Germany Tel:
WE CARE ACCURATELY ACCURA Medizintechnik GmbH Max-Planck-Straße 33-61184 Karben / Germany Tel: +49 6039 92010 Email: info@accuramed.de WELCOME TO ACCURA About ACCURA ACCURA Medizintechnik GmbH supplies
More informationUnit 7. Math Problem 1. This segment will go through the endpoint of the original line segment, perpendicular to the line segment.
Math 1007 Unit 7 1 Construct a square with sides equal to r. 1: Extend the segment and draw a circle centered at one of the endpoints of the segment 2: Draw two larger congruent circles centered where
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI
Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More informationArterial Spin Labeling Read-Out Options
Arterial Spin Labeling Read-Out Options Matthias Günther 1,2,3 1 Fraunhofer MEVIS, Institute for Medical Image Computing 2 Faculty 01 (Physics/Electrical Engineering), University Bremen 3 mediri GmbH,
More informationDIAGNOSTIC CARDIOLOGY
DIAGNOSTIC CARDIOLOGY For Your Procedural Needs Manufactured to the Highest Standards, Customised to Your Specific Needs MEDLINE PROCEDURE PACKS The items contained within this brochure are perfect for
More informationPICU Resident Self-Study Tutorial The Basic Physics of Oxygen Transport. I was told that there would be no math!
Physiology of Oxygen Transport PICU Resident Self-Study Tutorial I was told that there would be no math! INTRODUCTION Christopher Carroll, MD Although cells rely on oxygen for aerobic metabolism and viability,
More informationArteriovenous Patterns in Beaked Whales
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Arteriovenous Patterns in Beaked Whales Alexander M Costidis, Ph.D. Biology and Marine Biology University of North Carolina
More informationLab #2: Blood pressure and peripheral circulation
Lab #2: Blood pressure and peripheral circulation Vertebrates have a closed circulatory system where the blood is always enclosed within blood vessels or the heart. Blood is pumped from the heart (the
More informationa. Kingdom: b. Phylum: c. Class: d. Order: e. Family: f. Genus: g. Species:
Pre-lab Discussion: The earthworm belongs to a group of animals called annelids (segmented worms). The body of an annelid is usually divided internally and externally into well-defined segments, which
More information(12) United States Patent Beyersdorf et al.
(12) United States Patent Beyersdorf et al. US006790230B2 (10) Patent N0.: (45) Date of Patent: Sep. 14, 2004 (54) VASCULAR IMPLANT (75) Inventors: Friedhelm Beyersdorf, Freiburg (DE); Georg Lutter, Freiburg
More informationAT Kelly Torso. Directions for Use
AT Kelly Torso Directions for Use Table of Contents Recommends 4 Items Included 5 Skills Taught 5 Preparing the Manikin for Use 6 Head 6 Lungs 6 Abdominal Thrust 6 Instructions for Use 6 Airway Management
More informationSeQuent Please NEO. Clinically proven Polymer-free Drug Coated Balloon Catheter. Vascular Systems
SeQuent Please NEO Clinically proven Polymer-free Drug Coated Balloon Catheter Vascular Systems 1 SeQuent Please NEO The Drug Coated Balloon with Clinical Evidence Polymer-Free Drug Delivery Moving forward
More informationCustomized rocker sole constructions
Customized rocker sole constructions German guidelines to improve results in daily practice Stief, Thomas Registered Association for the Encouragement of Research and Education Management in Orthopedic
More informationCapillaries & 1513N Series
1513 & 1513N Series he 1513 series is an excellent general purpose capillary suitable for a wide range of applications on a variety of metalizations. his series employs the double and 8 face angle architecture.
More informationK&B Vault and Riser Closures
K&B Vault and Riser Closures K&B Vault Closures K&B Closures are strong, lightweight, and protect a wide variety of vault splice configurations with an air and water tight seal. K&B closures offer a full
More informationExercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.
Exercise 5-2 Bubblers EXERCISE OBJECTIVE Learn to measure the level in a vessel using a bubbler. DISCUSSION OUTLINE The Discussion of this exercise covers the following points: Bubblers How to measure
More informationThe following lesson is excerpted from
The following lesson is excerpted from A Fresh Approach to the Snare Drum is the most comprehensive method available that simultaneously provides instruction for rhythm reading, technique fundamentals,
More informationCritical Disposables. Non-Sterile Angiographic Accessories. for Medical Device Manufacturers & Kit Packers
Critical Disposables Non-Sterile Angiographic Accessories for Medical Device Manufacturers & Kit Packers Non-Sterile Angiographic Accessories DEROYAL PRODUCTS FOR CARDIOLOGY & ANGIOGRAPHY Whether it s
More informationSocket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11
Screwless Clamp Terminal Socket P2RF@@S Screwless clamping greatly contributes to reducing wiring time. No over or under tightening of cable connection so better contact reliability is achieved. Double
More informationFirst Stage Regulators
DOMESTIC First stage regulators are typically used to reduce tank pressure to an intermediate pressure, usually 5 to 10 PSI for further pressure reduction by a second stage regulator located closer to
More informationOperator Interface Enclosures
` www.hammfg.com s - NEMA 12, 13 Tara Plus 600 (135.2 lbs) 500 (112.4 lbs) Weight in Newtons 400 (90.1 lbs) 300 (67.4 lbs) 200 (45.1 lbs) 100 (22.5 lbs) 0.50 (1.6 ft) 1.00 (3.28 ft) Extension in Meters
More informationDSL# Rev. 12/ All Rights Reserved. PR1011-HS. Product Catalog
DSL#0-0457 Rev. 12/0 200 All Rights Reserved. PR1011-HS Product Catalog Harmonic Product Catalog Table of Contents Product Page Laparoscopic Harmonic Shears Laparoscopic Harmonic ACE 2 Open Harmonic Shears
More informationAT Kelly Torso. Directions for Use
AT Kelly Torso Directions for Use 260-00001 2 Table of Contents Recommends 4 Items Included 5 Skills Taught 5 Preparing the Manikin for Use 6 Head 6 Lungs 6 Abdominal Thrust 6 Instructions for Use 6 Airway
More informationThe NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works:
Dream Kit The NAMIC Dream Kit Single Operator Control. Reduce Contrast Waste. Less Force to Inject. For more than 40 years, NAMIC * Fluid Management products have been providing cardiologists, technicians
More informationQuiz for Module 2: Aquarius Training (Rev. 1) Lesson 1: Introduction to Aquarius
Quiz for Module 2: Aquarius Training (Rev. 1) Lesson 1: Introduction to Aquarius page 1 of 2 Name: Date: Score: Instructor: Location: Please circle the correct answers: 1. Select the answer(s) that represent
More informationi NOTE: This installation manual contains important information related to system
TRx Pivot Plus Manual Elevating Legrests (ELR) Installation and Set-Up Manual i NOTE: This installation manual contains important information related to system set-up and adjustments. Please forward to
More informationSTANDARD OPERATING PROCEDURE ADVANCED INTRAVENOUS TRAINING ARM (S )
Page 1 of 27 1. Scope This Standard Operating Procedure (SOP) applies to the staff and students using the Advanced Intravenous Training Arm in the Pharmacy Practice Resource Unit (PPRU) at the Pharmacy
More informationSECTION 4 - POSITIVE CASTING
4-1 SECTION 4 - POSITIVE CASTING THE SHAPE OF THE SHELL IS DERIVED FROM THE SHAPE OF THE CAST Thermo-forming plastic for orthopedic intervention was originally developed at the University of California
More informationGALLIUM PRO 210A: ASSEMBLY GUIDE
GALLIUM PRO 210A: ASSEMBLY GUIDE Revision 5.0-05-23-2017 GALLIUM PRO 210A: Table of contents Assembly overview...2-3 1. Frame inspection...4 2. Headset installation...5 3. Cables & housing installation...6-9
More informationNever operate the Peripheral RotaLink Plus with the Rotablator
91119961-01 Rotablator Rotational Atherectomy System ONLY Caution: Federal Law (USA) restricts this device to sale by or on the order of a physician. WARNING Contents supplied STERILE using an ethylene
More informationDimensions & Specifications
Dimensions & Specifications These pages illustrate our commonly used punches, dies and related tooling for Mubea Ironworkers. Refer to our Cross Reference Catalog for the proper tooling to fit your machine.
More information2MW baseline wind turbine: model development and verification (WP1) The University of Tokyo & Hitachi, Ltd.
2MW baseline wind turbine: model development and verification (WP1) The University of Tokyo & Hitachi, Ltd. Downwind turbine technology, IEA Wind Task 40 First Progress Meeting, Tokyo, Japan 11 Dec, 2017
More informationFLEXIBLE SHAFTING (Wet & Dry)
TM-5 April 5, 2004 Elliott offers a complete line of precision tube tools, including: tube expanders Boiler Expanders Heat Exchanger Expanders Condenser Expanders Refinery Expanders tube rolling motors
More informationUSG Ceiling Solutions. LOGIX Integrated Ceiling Systems INSTALLATION GUIDE
USG Ceiling Solutions LOGIX Integrated Ceiling Systems INSTALLATION GUIDE LOGIX Integrated Ceiling Systems INSTALLATION GUIDE Logix Brand Integrated Ceiling Systems integrated ceiling systems from USG
More informationThe Agility Association of Canada
Check list to Prepare for Equipment Inspection 2018 Introduction: requires that all equipment used at sanctioned events be inspected and approved at least four months before a host s first trial, and regularly
More informationCOLLECTION OF BLOOD. Types of patients
COLLECTION OF BLOOD Capillary Sampling The specimen of choice for laboratory analysis is generally a venous specimen. For blood gas analysis, the specimen of choice originates from an arterial draw. When
More informationRecitation question # 05
Recitation and Lab # 05 The goal of this recitations / labs is to review material related to the CV and respiratory lectures for the second test of this course. Info required to answer this recitation
More informationBlood Pressure Monitoring: Arterial Line
Approved by: Blood Pressure Monitoring: Arterial Line Gail Cameron Senior Director, Operations, Maternal, Neonatal & Child Health Programs Dr. Ensenat Medical Director, Neonatology Neonatal Nursery Policy
More informationTraining Device Instructions
Training Device Instructions May 2011 www.pyng.com 2011 Pyng Medical Corp. Pyng Medical has developed two types of devices to aid in the training curriculum of the FAST1 : The FAST1 Training Device and
More informationInstructions and User Guide. Ultrasound Central Line Training Models BPH660 Series, BPH665-C Series, BPHNB670 Series, BPHNB675-C Series
Instructions and User Guide Ultrasound Central Line Training Models BPH660 Series, BPH665-C Series, BPHNB670 Series, BPHNB675-C Series November 23, 2011 Rev 1.0 Contents 3 Chapter One: Overview 3 Giving
More informationPhysiology Unit 4 RESPIRATORY PHYSIOLOGY
Physiology Unit 4 RESPIRATORY PHYSIOLOGY In Physiology Today Respiration External respiration ventilation gas exchange Internal respiration cellular respiration gas exchange Respiratory Cycle Inspiration
More informationExtra wide viewing angle from single indicator lamp. Lenses made from polycarbonate and hardened glass. 10mm Panel Hole.
NORDIC N5 Headlamp The N5 integrates head light, indicator and park light in one assembly. This heavy duty light incorporates an adaptable single bolt mount featuring over 1 o of adjustment. ADR compliant
More informationNow that you have a Safety Break or
The SAFETY BREAK SYSTEM User Instructions push block breaking button Glass Breaking Tools The three-part UN-PLIER CENTER Safety Break Safety Break System and the onepiece M-80 allow glass breaking anywhere
More informationExercise 18B Class Chondrichthyes Cartilaginous Fishes
AP Biology Chapter 24 Exercise #18: Chordates: Fish Cartilaginous Fishes Lab Guide Exercise 18B Class Chondrichthyes Cartilaginous Fishes This group contains about 970 species that are characterized by
More information*
Email: * cheekong@krdl.org.sg 336 X. Ma et al. procedures such as stent placement. Commercially available devices are based on the original mechanical design of the Gruentzig s device. Physicians have
More informationVariSource High Dose Rate Afterloader Procedures. For Performing Breast Brachytherapy with. The SAVI TM Applicator
VariSource High Dose Rate Afterloader Procedures For Performing Breast Brachytherapy with The SAVI TM Applicator Contents I. CT Evaluation (~1 week prior to insertion) II. SAVI Applicator Implantation
More information2. State the volume of air remaining in the lungs after a normal breathing.
CLASS XI BIOLOGY Breathing And Exchange of Gases 1. Define vital capacity. What is its significance? Answer: Vital Capacity (VC): The maximum volume of air a person can breathe in after a forced expiration.
More informationBielefeld. Balloon Catheter The new treatment for chronic tube malfunction. Innovations by Spiggle & Theis
C2 C3 C4 C1 Bielefeld Balloon Catheter The new treatment for chronic tube malfunction Innovations by Spiggle & Theis A new therapy concept for the treatment of chronic tube dysfunction Obstructive tube
More informationAn In Vitro Analysis of a One-Way Arterial Check Valve
Original Article An In Vitro Analysis of a One-Way Arterial Check Valve Michael A. Springer, BS, Douglas C. Korth, BS, Pamela J. Guiterrez, RN, BSN, John F. Morrow, BS, Alfred H. Stammers, MSA, CCP Division
More informationTrials of a Net Grid for the UK Nephrops trawl fisheries
Trials of a Net Grid for the UK Nephrops trawl fisheries Tom Catchpole, Frank Armstrong, Stuart Masson, Dave Price, Mark O Brien & John Hingley June 2012 This work was funded by Defra Executive Summary
More informationFRA Spacer Instruments. For anterior lumbar interbody fusion (ALIF) using straight anterior or anterolateral approach.
FRA Spacer Instruments. For anterior lumbar interbody fusion (ALIF) using straight anterior or anterolateral approach. Technique Guide Instruments and implants approved by the AO Foundation Table of Contents
More informationGUNDERSEN HEALTH SYSTEM ULTRASOUND DEPARTMENT POLICY AND PROCEDURE MANUAL
GUNDERSEN HEALTH SYSTEM ULTRASOUND DEPARTMENT POLICY AND PROCEDURE MANUAL SUBJECT: Venous Insufficiency (Reflux) Ultrasound SECTION: Vascular Ultrasound ORIGINATOR: Kraig Schuster REVISED DATE: February
More informationKRYPTON X ROAD : ASSEMBLY GUIDE
KRYPTON X ROAD : ASSEMBLY GUIDE KRYPTON X ROAD : Table of contents Assembly overview.........................2 1. Frame inspection........................3 2. Headset installation.......................4
More informationBHN SURGICALS Pvt.Ltd
BHN SURGICALS Pvt.Ltd Manufacturing - Technology - Marketing TITANIUM INSTRUMENTS Micro Tissue Forceps TITANIUM Ring Smooth A B Fig A BRF 01.50 A BRF 01.80 A BRF 02.10 B BRF 01.51 B BRF 01.81 B BRF 02.11
More informationExplorer Plus a new dimension in play
Explorer Plus a new dimension in play Explorer Plus a new dimension in play. Innovation, quality, usability and fun were key drivers in the development of the Explorer Plus range. The Explorer Plus range
More informationNo guesswork. Controllable tension for labral repairs of the shoulder and hip. BIORAPTOR Knotless Suture Anchor
No guesswork Controllable tension for labral repairs of the shoulder and hip BIORAPTOR Knotless Suture Anchor The BIORAPTOR Knotless Suture Anchor allows surgeons to control anchor tension in labrum repairs
More informationDesign and Development of Pressure Sensing Bandage
GRD Journals- Global Research and Development Journal for Engineering Volume 2 Issue 5 April 2017 ISSN: 2455-5703 Design and Development of Pressure Sensing Bandage Pudhumozhi Subramanian Department of
More informationJ.A. BAIN AND W.E. SPOEREL~
PREDICTION OF ARTERIAL CARBON DIOXIDE TENSION DURING CONTROLLED VENTILATION WITH A MODIFIED MAPLESON D SYSTEM* J.A. BAIN AND W.E. SPOEREL~ ThE OBSERVATION that relatively low fresh gas inflows are adequate
More informationOperation Manual. Diaphragm Sensed Gas Pressure Regulators
687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Diaphragm Sensed Gas (AP/AZ/AK Models: 20, 100, 500, 1000, 1000T 10PA, 1100, 1200, 12PA, 1300, 1400T, 14PA,
More information